metering
**German energy metering domain library — interval types, gas conversion, billing period aggregation, SLP/RLM/iMSys classification, BSI TR-03109 SMGW lifecycle, virtual meters (§42b EnWG GGV Solarpaket I), resampling, forecasting, and Hampel-filter quality scoring.
214 tests · zero I/O · no async · no float money**
metering is the pure domain library used by edmd,
mako-gabi-gas, and mako-mabis for all
metering arithmetic. It has no I/O, no async, and no floating-point money.
Modules at a glance
| Module | Key types | Purpose |
|---|---|---|
interval |
MeterInterval, QualityFlag, Sparte |
Core interval + quality types |
obis |
ObisCode |
Typed OBIS codes (IEC 62056-21 / BDEW) with default_resolution() |
validation |
ValidationEngine, ValidationIssue (V01–V10) |
Gap / overlap / spike / DST / rollover detection |
substitute |
fill_gaps(), SubstituteMethod, SubstitutionReason |
§17 MessZV Ersatzwertbildung |
forecast |
project_annual_consumption(), prior_period_substitutes() |
§17 MessZV Jahresprognose + §17 Abs. 2 prior-period gap-fill |
resample |
resample(), ResampledBucket |
Down-sample 15-min → hourly / daily / monthly |
virtual_meter |
compute_virtual_meter(), AggregationRule |
§42b EnWG GGV: GgvConstantAllocation (CCI+ZG6) + GgvProportionalAllocation (variable); Residuallast (§42a) |
smgw |
SmgwSession, ClsChannel, GatewayCertificate |
BSI TR-03109 gateway lifecycle, §14a CLS channels |
measurement_point |
MeasurementPoint, MarktRolle, EnergyFlow |
MaLo + MeLo + OBIS + role binding |
measurement_series |
MeasurementSeries, MeasurementSource, ProvenanceEntry |
§22 MessZV provenance / explainability |
register |
MeterRegister, EnergyDirection, RegisterUnit |
HT/NT register + Wandlerfaktor metadata |
aggregation |
aggregate(), BillingPeriod, HtNtSplit |
§2 Nr. 17 MessZV Spitzenleistung + HT/NT |
classification |
classify_messtyp(), Messtyp |
SLP/RLM/iMSys (§3/§4 MessZV, §41a EnWG) |
quality |
score_intervals(), QualityGrade |
Hampel-filter quality scoring (A/B/C/F) |
demand |
DemandWindow, DemandInterval |
15-min demand / Spitzenleistung |
tariff_window |
TariffWindow, HtNtSchedule |
DST-aware HT/NT window classification |
load_profile |
LoadProfile |
German SLP load profile types (H0/G0–G6/L0–L2 …) |
conversion |
gas_m3_to_kwh_hs(), GasConversionParams |
§25 Nr. 4 MessEV / DVGW G 685 |
imbalance |
compute_imbalance(), ImbalanceSaldo |
§27 MessZV Mehr-/Mindermengensaldo |
resolution |
IntervalResolution |
Typed interval lengths (15-min / hourly / daily …) |
sharing |
§42c EnWG Energy-Sharing metering eligibility — pure capability/delivery rules over Messtyp and IntervalLengthClass |
|
lifecycle |
MeterExchangeEvent, MeterStatus |
WiM meter exchange domain events |
Design constraints
| Constraint | Detail |
|---|---|
| No I/O | All inputs are passed as arguments. |
| No async | Synchronous throughout. |
| No float money | All energy amounts use rust_decimal::Decimal. |
| Deterministic | Same inputs always produce the same output. |
Core types
MeterInterval
A single timestamped energy reading:
Sparte and MeasurementUnit
A Sparte has two units, and conflating them is a correctness bug:
Sparte |
measured_unit() |
billing_unit() |
requires_conversion() |
|---|---|---|---|
Strom |
kWh | kWh | no |
Gas |
m³ | kWh | yes |
Waerme |
kWh | kWh | no |
Wasser |
m³ | m³ | no |
A gas meter registers volume; its energy content is derived from Brennwert and
Zustandszahl (gas_m3_to_kwh_hs). requires_conversion() lets an ingest path
require those parameters before storing a value in an energy column.
Wasser is the one Sparte billed in a volume — water has no calorific value, so
the gas conversion does not apply to it. For the heat share of warm water see
HeizkostenV §9 Abs. 2.
Wire units vs storage units
Storage is canonical — exactly two units reach a database, so no consumer has to know the table below exists. The wire is liberal, because real devices are:
parse // None — would need rescaling
parse_scaled // Some(UnitScale { KiloWattHour, 1000, 1 })
| Accepted | Canonical | Factor |
|---|---|---|
kWh, kWh_th, kWh_Hs |
kWh | 1 |
Wh / MWh / GWh |
kWh | 1/1000 · 1000 · 10⁶ |
GJ |
kWh | 2500/9 |
MJ |
kWh | 5/18 |
m³, m3, cbm |
m³ | 1 |
l, ltr, liter |
m³ | 1/1000 |
No German law prescribes a unit for heat meters. MID Annex VI (MI-004) has no units clause, and EN 1434-1 cl. 6.3.1 permits "Joules, Watt-hours or decimal multiples of those units" — so a GJ meter is exactly as compliant as a kWh one. German heat meters ship with kWh, MWh or GJ registers depending on the ordered variant (ista sensonic 3 is sold in both kWh and GJ; Zenner multidata WR3 offers MJ), and water submeters commonly report litres. The register unit is therefore device metadata, not a constant.
UN/ECE Rec 20 codes are also accepted, and their mnemonics do not follow the unit symbols:
| Rec 20 | Means | Trap |
|---|---|---|
MTQ |
cubic metre | not M3 |
GV |
gigajoule | not GJ |
3B |
megajoule | MJ is not a Rec 20 code |
WHR / JOU / KJO |
watt hour / joule / kilojoule |
Rec 20 also assigns GJ to gram per millilitre. This crate reads GJ as
gigajoule, since no Sparte modelled here carries a density; callers emitting Rec 20
codes should send GV.
The GJ and MJ factors are held as exact rationals, not decimals: 1 GJ is
277.7… kWh, so a Decimal factor would lose precision on every reading.
UnitScale::apply multiplies before dividing, making 3.6 GJ exactly 1000 kWh.
parse rejects anything needing a rescale, so a caller must go through
parse_scaled to obtain a factor.
QualityFlag (8 variants)
| Variant | Billable | Description |
|---|---|---|
Measured |
✅ | Direct meter reading |
Estimated |
✅ | Prognosewert (valid for Abschlag per §17 MessZV) |
Substituted |
✅ | §17 MessZV Ersatzwert |
Calculated |
✅ | Derived (e.g. Residuallast) |
Corrected |
✅ | Retroactive correction |
Preliminary |
✅ | Vorläufiger Wert |
Faulty |
❌ | Must not be billed |
Unknown |
❌ | Quality not determinable |
Gas conversion: m³ → kWh_Hs
Implements the Brennwertkorrektur formula per §25 Nr. 4 MessEV / DVGW G 685:
// kWh_Hs = m³ × Hs × Z (rounded to 6 dp)
let kwh = gas_m3_to_kwh_hs;
Warm water → heat energy (HeizkostenV §9 Abs. 2)
warm_water_heat_kwh
warm_water_heat_kwh_unmetered
Q [kWh/a] = 2.5 × V [m³] × (t_w [°C] − 10) // Satz 2, metered volume
Q [kWh/a] = 32 × A_Wohn [m²] // Satz 4, floor area
Both are fallbacks. §9 Abs. 2 Satz 1 requires a Wärmezähler; Satz 2 applies only where measurement is possible "nur mit einem unzumutbar hohen Aufwand", and Satz 4 only "in Ausnahmefällen" where neither the heat quantity nor the volume can be measured.
These are Zahlenwertgleichungen — numerical-value equations, not dimensionally consistent — so the constants carry no unit, and they bundle different things:
| Constant | Covers (§9 Abs. 2 Satz 3/5) |
|---|---|
| 2.5 | Erzeugeraufwandszahl, mittlere spezifische Wärmekapazität des Wassers, Wärmeverluste für Warmwasserspeicher, Verteilung einschließlich Zirkulation, Messdatenerhebungen |
| 32 | Nutzwärmebedarf für Warmwasser, Erzeugeraufwandszahl, Messdatenerhebungen — no Speicher-, Verteilungs- oder Zirkulationsverluste |
Because the Erzeugeraufwandszahl sits inside both constants, Q is generator-input heat, not delivered useful heat.
t_w is "die gemessene oder geschätzte mittlere Temperatur" — an estimate is
permitted and no default or cap is prescribed. A_Wohn is the "Wohn- oder
Nutzfläche", not living area alone.
WarmWaterAdjustments
| Field | Effect | Trigger |
|---|---|---|
brennwert_erdgas |
× 1.11 | brennwertbezogene Abrechnung von Erdgas |
eigenstaendige_gewerbliche_waermelieferung |
÷ 1.15 | eigenständige gewerbliche Wärmelieferung |
monovalente_waermepumpe |
× 0.30 | Betrieb einer monovalenten Wärmepumpe |
A struct of flags rather than an enum: §9 Abs. 2 Satz 6 applies these to the result
of "den Zahlenwertgleichungen in Satz 2 oder 4" and does not make them exclusive,
so a heat-pump system under eigenständige gewerbliche Wärmelieferung takes both.
eigenständig is a term of art (cf. §1 Abs. 1 Nr. 2); ordinary commercial heat
supply does not qualify.
A warm-water meter therefore carries two quantities: the m³ billed as water,
and the kWh this apportions out of the building's heating bill. The metered and
floor-area forms are separate functions rather than one Option parameter, because
they are different evidentiary categories.
Validation engine (V01–V10)
let result = validate_intervals;
println!;
println!;
| Rule | ID | Detects |
|---|---|---|
| Gap detected | V01 | Missing intervals between adjacent reads |
| Overlap detected | V02 | Two intervals covering the same timestamp |
| Negative energy | V03 | value_kwh < 0 for import registers |
| Impossible spike | V04 | value_kwh > spike_factor × window_median |
| Suspicious zero run | V05 | Long sequence of zero values |
| Inconsistent interval | V06 | Mixed 15-min and 60-min in same series |
| DST ambiguity | V07 | Potential local-time leak at CEST→CET fall-back |
| Future timestamp | V08 | from > now |
| Non-billable quality | V09 | Faulty or Unknown intervals in billing window |
| Register rollover | V10 | Counter reset without meter-exchange event |
§17 MessZV substitute value generation
// Automatic: linear for short gaps, carry-forward for long
let filled = fill_gaps;
// Prior-period averaging per §17 Abs. 2 MessZV
let filled = fill_gaps_with_config;
// Annual forecast (Jahresprognose)
let forecast = project_annual_consumption?;
println!;
SubstituteMethod |
When to use |
|---|---|
LinearInterpolation |
Short gaps (≤ 3 intervals) with surrounding data |
PriorPeriodAverage |
Same time-slot from prior reference week (§17 Abs. 2) |
ZeroFill |
Documented plant shutdown — affirmative zero only |
LastValueCarryForward |
Conservative fallback |
Resampling
// Down-sample 15-min RLM data to monthly totals (for MaBiS §27 MessZV)
let monthly = resample;
for bucket in &monthly
Virtual meters (§42b EnWG GGV — Solarpaket I)
Both GGV variants compute the tenant's net grid draw after PV allocation,
satisfying §42b Abs. 5 EnWG sentence 2: the allocated PV energy can never exceed
the tenant's actual consumption in any 15-minute interval. This is enforced by the
Pos() = max(0, x) operator per the BDEW "Anwendungshilfe Berechnungsformeln
Solarpaket 1" (v1.0, 25.01.2024).
Formula overview
Constant allocation (BDEW Beispiel 1 — UTILTS CCI+ZG6):
net_grid_draw_i[t] = max(0, tenant_consumption_i[t] - fraction_i × plant_generation[t])
Proportional allocation (BDEW Beispiel 3 — variable ratio):
ratio_i[t] = tenant_consumption_i[t] / Σ all_tenant_consumption_j[t]
(0 if denominator = 0 — zero-division protected)
net_grid_draw_i[t] = max(0, tenant_consumption_i[t] - ratio_i[t] × plant_generation[t])
Constant allocation (Beispiel 1 — UTILTS CCI+ZG6)
// Tenant receives 10 % of plant generation; result = net grid draw
let rule = GgvConstantAllocation ;
let net_grid_draw = compute_virtual_meter?;
// Each interval: max(0, tenant_consumption - 0.10 × plant_generation)
// Examples:
// gen=10, consumption=5 → max(0, 5 - 1) = 4 (1 kWh covered by PV)
// gen=10, consumption=0.5 → max(0, 0.5 - 1) = 0 (§42b cap: no negative draw)
Proportional allocation (Beispiel 3 — variable ratio)
let rule = GgvProportionalAllocation ;
let net_grid_draw = compute_virtual_meter?;
// ratio = T2_consumption / (T2 + T3); net = max(0, T2 - ratio × generation)
// zero-division protected: if all consumptions are 0 → net = 0
Energy balance check (plant feed-in)
The residual plant feed-in (grid export from PV) equals:
plant_feedin[t] = plant_generation[t] - Σ (tenant_consumption_i[t] - net_grid_draw_i[t])
= plant_generation[t] - Σ pv_allocated_i[t]
Available rules: Sum, Residual (§42a EEG), PvSelfConsumption,
GgvConstantAllocation, GgvProportionalAllocation (§42b EnWG Solarpaket I).
BSI TR-03109 SMGW lifecycle
let session = SmgwSession ;
// Certificate expiry (BSI TR-03109-4 §6.3 — renew ≥ 30 days before expiry)
let expiring = session.expiring_certificates;
// §14a CLS channel compliance
assert!;
// Communication fault detection (triggers §17 MessZV substitute)
if session.is_communication_fault
Billing period aggregation
let agg = aggregate;
println!;
println!;
println!;
println!;
AggregationConfig presets
| Preset | Messtyp | Detail |
|---|---|---|
rlm_strom() |
RLM | Spitzenleistung §2 Nr. 17 MessZV + DST-aware HT/NT |
slp_strom() |
SLP | HT/NT split only |
rlm_zweitarif() |
RLM | Custom HT/NT window |
gas() |
Gas | Single total (m³ → kWh_Hs, no tariff split) |
SLP/RLM/iMSys classification
Messtyp |
Criteria | Basis |
|---|---|---|
Slp |
< 100 MWh/a (Strom) or < 1.500 MWh/a (Gas) | §3 MessZV |
Rlm |
≥ 100 MWh/a (Strom) or ≥ 1.500 MWh/a (Gas) | §4 MessZV |
Imsys |
Pflichteinbau iMSys (§41a EnWG) | §41a EnWG |
OBIS medium (value group A)
ObisCode::is_heat, is_water and is_heat_cost_allocator follow the
DLMS/COSEM Blue Book media list that OMS Spec Vol. 2 adopts:
| A | Medium | Predicate |
|---|---|---|
| 1 | Electricity | is_electricity() |
| 4 | Heizkostenverteiler | is_heat_cost_allocator() |
| 5 / 6 | Cooling / heat | is_heat() |
| 7 | Gas | is_gas() |
| 8 / 9 | Cold / hot water | is_water() |
A = 8 is water, not heat. An HCA (A = 4) reports dimensionless Verbrauchseinheiten and carries no Eichfrist — HeizkostenV §5 Abs. 1 Satz 3 admits it as an apportionment device precisely because it measures no unit.
Mehr-/Mindermengensaldo
ImbalanceResult contains delta_kwh and delta_pct.
Positive = Mehrmenge (actual > forecast); negative = Mindermenge.
Basis: §27 MessZV.
Hampel-filter quality scoring
score_intervals runs a Hampel filter over a time-ordered slice of intervals
and returns per-interval QualityGrades:
Media-aware thresholds
for_sparte
Sparte |
max_zero_run_allowed |
min_sigma |
|---|---|---|
Strom |
2 | 0.0 |
Gas |
48 | 0.01 |
Waerme |
720 | 0.05 |
Wasser |
720 | 0.001 |
min_sigma guards MAD implosion: across a flat window the median absolute
deviation is 0, so t × sigma is 0 and every nonzero value scores as an outlier.
hampel_filter_with_floor exposes the same guard as a primitive.
QualityGrade
| Grade | Meaning | Effect in edmd |
|---|---|---|
A |
Clean — within threshold | Billing proceeds normally |
B |
Slightly suspicious | Logged; billing proceeds |
C |
Likely outlier | de.edmd.reading.quality.warning CloudEvent emitted |
F |
Severe outlier / substituted | Billing run blocked; operator alert |
hampel_filter is also exposed as a low-level primitive that returns raw
outlier indices.
Feature flags
| Flag | Effect |
|---|---|
serde |
Derive Serialize/Deserialize on all public types |
Testing
214 tests covering: gas conversion (DVGW G 685), aggregation (RLM/SLP/Gas), Messtyp classification, imbalance arithmetic, V01–V10 validation engine (incl. DST transitions and V07 DST ambiguity), §17 MessZV substitute methods, resampling (hourly/daily/monthly), §42b EnWG GGV virtual meters (Beispiel 1 constant + Beispiel 3 proportional, Pos() cap, zero-division guard), §42a Residuallast, BSI TR-03109 SMGW + CLS lifecycle, measurement series provenance, register + ObisCode.
Regulatory basis
- §3, §4 MessZV — SLP/RLM classification thresholds
- §2 Nr. 17 MessZV — Spitzenleistung definition for RLM
- §17 MessZV — Ersatzwertbildung + Jahresprognose (substitute values + annual forecast)
- §22 MessZV — 3-year provenance retention (
MeasurementSeries,ProvenanceEntry) - §27 MessZV — Mehr-/Mindermengensaldo
- §25 Nr. 4 MessEV / DVGW G 685 — Gas Brennwertkorrektur
- §41a EnWG — 15-Minuten-Lastgang and iMSys Pflichteinbau
- §42a/§42b EEG — Residuallast / GGV community solar virtual meters
- §14a EnWG — Steuerbare Verbrauchseinrichtungen (CLS channels)
- BSI TR-03109 — Smart Meter Gateway lifecycle and certificates