metering 0.11.0

German energy metering domain library — interval types, Gas conversion (m3→kWh_Hs), billing period aggregation (Spitzenleistung, HT/NT), SLP/RLM/iMSys classification, Mehr-/Mindermengensaldo, and Hampel-filter quality scoring. Zero I/O, no async, no float money.
Documentation

metering

German energy metering domain library — interval types, gas conversion, billing period aggregation, SLP/RLM/iMSys classification, BSI TR-03109 SMGW lifecycle, virtual meters, resampling, forecasting, and Hampel-filter quality scoring.

metering is the pure domain library used by edmd, mako-gabi-gas, and mako-mabis for all metering arithmetic. It has no I/O, no async, and no floating-point money.

Modules at a glance

Module Key types Purpose
interval MeterInterval, QualityFlag, Sparte Core interval + quality types
obis ObisCode Typed OBIS codes (IEC 62056-21 / BDEW) with default_resolution()
validation ValidationEngine, ValidationIssue (V01–V10) Gap / overlap / spike / DST / rollover detection
substitute fill_gaps(), SubstituteMethod, SubstitutionReason §17 MessZV Ersatzwertbildung
forecast project_annual_consumption(), prior_period_substitutes() §17 MessZV Jahresprognose + §17 Abs. 2 prior-period gap-fill
resample resample(), ResampledBucket Down-sample 15-min → hourly / daily / monthly
virtual_meter compute_virtual_meter(), AggregationRule §42b EEG GGV community solar, Residuallast
smgw SmgwSession, ClsChannel, GatewayCertificate BSI TR-03109 gateway lifecycle, §14a CLS channels
measurement_point MeasurementPoint, MarktRolle, EnergyFlow MaLo + MeLo + OBIS + role binding
measurement_series MeasurementSeries, MeasurementSource, ProvenanceEntry §22 MessZV provenance / explainability
register MeterRegister, EnergyDirection, RegisterUnit HT/NT register + Wandlerfaktor metadata
aggregation aggregate(), BillingPeriod, HtNtSplit §2 Nr. 17 MessZV Spitzenleistung + HT/NT
classification classify_messtyp(), Messtyp SLP/RLM/iMSys (§3/§4 MessZV, §41a EnWG)
quality score_intervals(), QualityGrade Hampel-filter quality scoring (A/B/C/F)
demand DemandWindow, DemandInterval 15-min demand / Spitzenleistung
tariff_window TariffWindow, HtNtSchedule DST-aware HT/NT window classification
load_profile LoadProfile German SLP load profile types (H0/G0–G6/L0–L2 …)
conversion gas_m3_to_kwh_hs(), GasConversionParams §24 GasGVV / DVGW G 685
imbalance compute_imbalance(), ImbalanceSaldo §27 MessZV Mehr-/Mindermengensaldo
resolution IntervalResolution Typed interval lengths (15-min / hourly / daily …)
lifecycle MeterExchangeEvent, MeterStatus WiM meter exchange domain events

Design constraints

Constraint Detail
No I/O All inputs are passed as arguments.
No async Synchronous throughout.
No float money All energy amounts use rust_decimal::Decimal.
Deterministic Same inputs always produce the same output.

Core types

MeterInterval

A single timestamped energy reading:

pub struct MeterInterval {
    pub from: OffsetDateTime,
    pub to:   OffsetDateTime,
    pub value_kwh: Decimal,
    pub quality: QualityFlag,
    pub obis_code: Option<String>,
}

QualityFlag (8 variants)

Variant Billable Description
Measured ✅ Direct meter reading
Estimated ✅ Prognosewert (valid for Abschlag per §17 MessZV)
Substituted ✅ §17 MessZV Ersatzwert
Calculated ✅ Derived (e.g. Residuallast)
Corrected ✅ Retroactive correction
Preliminary ✅ Vorläufiger Wert
Faulty ❌ Must not be billed
Unknown ❌ Quality not determinable

Gas conversion: m³ → kWh_Hs

Implements the Brennwertkorrektur formula per §24 GasGVV / DVGW G 685:

// kWh_Hs = m³ × Hs × Z  (rounded to 6 dp)
let kwh = gas_m3_to_kwh_hs(dec!(100), dec!(10.55), dec!(0.9764));

Validation engine (V01–V10)

let result = validate_intervals(&intervals, &ValidationConfig::default());
println!("Issues: {}", result.issues.len());
println!("Billing blocked: {}", result.billing_block_count());
Rule ID Detects
Gap detected V01 Missing intervals between adjacent reads
Overlap detected V02 Two intervals covering the same timestamp
Negative energy V03 value_kwh < 0 for import registers
Impossible spike V04 value_kwh > spike_factor × window_median
Suspicious zero run V05 Long sequence of zero values
Inconsistent interval V06 Mixed 15-min and 60-min in same series
DST ambiguity V07 Potential local-time leak at CEST→CET fall-back
Future timestamp V08 from > now
Non-billable quality V09 Faulty or Unknown intervals in billing window
Register rollover V10 Counter reset without meter-exchange event

§17 MessZV substitute value generation

// Automatic: linear for short gaps, carry-forward for long
let filled = fill_gaps(&intervals, 900, period_from, period_to);

// Prior-period averaging per §17 Abs. 2 MessZV
let filled = fill_gaps_with_config(
    &intervals, 900, period_from, period_to,
    &FillGapsConfig::prior_period(prior_week_intervals),
);

// Annual forecast (Jahresprognose)
let forecast = project_annual_consumption("MALO_ID", &intervals, None)?;
println!("Projected annual kWh: {}", forecast.projected_annual_kwh);
SubstituteMethod When to use
LinearInterpolation Short gaps (≤ 3 intervals) with surrounding data
PriorPeriodAverage Same time-slot from prior reference week (§17 Abs. 2)
ZeroFill Documented plant shutdown — affirmative zero only
LastValueCarryForward Conservative fallback

Resampling

// Down-sample 15-min RLM data to monthly totals (for MaBiS §27 MessZV)
let monthly = resample(&intervals, &ResampleConfig::to_monthly());
for bucket in &monthly {
    println!("{}: {} kWh (coverage {:.1}%)",
        bucket.from.date(), bucket.total_kwh, bucket.coverage_pct());
}

Virtual meters (§42b EEG GGV)

let rule = AggregationRule::GgvAllocation {
    plant_malo_id: "PLANT".into(),
    tenant_fractions: vec![("TENANT_A".into(), dec!(0.4)), ("TENANT_B".into(), dec!(0.35))],
};
let virtual_series = compute_virtual_meter(&rule, &source_map)?;

Available rules: Sum, Residual (§42a EEG), PvSelfConsumption, GgvAllocation (§42b EEG).


BSI TR-03109 SMGW lifecycle

let session = SmgwSession { device_id, status, certificates, cls_channels, .. };

// Certificate expiry (BSI TR-03109-4 §6.3 — renew ≥ 30 days before expiry)
let expiring = session.expiring_certificates(today, 30);

// §14a CLS channel compliance
assert!(session.has_section_14a_cls());

// Communication fault detection (triggers §17 MessZV substitute)
if session.is_communication_fault(2) { // 2h threshold
    // create Sonderablesung reading order
}

Billing period aggregation

let agg = aggregate(&intervals, &AggregationConfig::rlm_strom());
println!("kWh total:    {}", agg.arbeitsmenge_kwh);
println!("kWh HT:       {:?}", agg.ht_kwh);
println!("kWh NT:       {:?}", agg.nt_kwh);
println!("Spitzenlast:  {:?} kW", agg.spitzenleistung_kw);

AggregationConfig presets

Preset Messtyp Detail
rlm_strom() RLM Spitzenleistung §2 Nr. 17 MessZV + DST-aware HT/NT
slp_strom() SLP HT/NT split only
rlm_zweitarif() RLM Custom HT/NT window
gas() Gas Single total (m³ → kWh_Hs, no tariff split)

Feature flags

Flag Effect
serde Derive Serialize/Deserialize on all public types

Testing

cargo test -p metering --all-features

177 tests covering: gas conversion (DVGW G 685), aggregation (RLM/SLP/Gas), Messtyp classification, imbalance arithmetic, V01–V10 validation engine (incl. DST transitions), §17 MessZV substitute methods, resampling (hourly/daily/monthly), virtual meters (GGV/Residual), BSI TR-03109 SMGW + CLS lifecycle, measurement series provenance, register + ObisCode.


Regulatory basis

  • §3, §4 MessZV — SLP/RLM classification thresholds
  • §2 Nr. 17 MessZV — Spitzenleistung definition for RLM
  • §17 MessZV — Ersatzwertbildung + Jahresprognose (substitute values + annual forecast)
  • §22 MessZV — 3-year provenance retention (MeasurementSeries, ProvenanceEntry)
  • §27 MessZV — Mehr-/Mindermengensaldo
  • §24 GasGVV / DVGW G 685 — Gas Brennwertkorrektur
  • §41a EnWG — 15-Minuten-Lastgang and iMSys Pflichteinbau
  • §42a/§42b EEG — Residuallast / GGV community solar virtual meters
  • §14a EnWG — Steuerbare Verbrauchseinrichtungen (CLS channels)
  • BSI TR-03109 — Smart Meter Gateway lifecycle and certificates

Design constraints

Constraint Detail
No I/O All inputs are passed as arguments.
No async Synchronous throughout.
No float money All energy amounts use rust_decimal.
Deterministic Same inputs always produce the same output.

Core types

MeterInterval

A single timestamped energy reading:

pub struct MeterInterval {
    pub period_start: OffsetDateTime,
    pub period_end: OffsetDateTime,
    pub value_kwh: Decimal,
    pub quality: QualityFlag,
}

Sparte

pub enum Sparte { Strom, Gas }

QualityFlag

Measured, Substituted, Estimated, Invalid — mapped to MSCONS/UTILTS Datenqualitätskennzeichen.


Gas conversion: m³ → kWh_Hs

pub fn gas_m3_to_kwh_hs(
    m3: Decimal,
    brennwert_kwh_m3: Decimal,
    zustandszahl: Decimal,
) -> Decimal

Implements the Brennwertkorrektur formula per §24 GasGVV / DVGW G 685:

$$kWh_{Hs} = m^3 \times z \times H_s$$


Billing period aggregation

aggregate computes a BillingPeriodAggregate from a slice of MeterIntervals:

let agg = aggregate(&intervals, &AggregationConfig::rlm_strom())?;
println!("kWh HT: {}", agg.kwh_ht);
println!("kWh NT: {}", agg.kwh_nt);
println!("Spitzenlast: {:?} kW", agg.spitzenleistung_kw);

AggregationConfig presets

Preset Messtyp Split
rlm_strom() RLM Spitzenleistung §2 Nr. 17 MessZV + HT/NT split
slp_strom() SLP HT/NT split (no Spitzenleistung)
rlm_zweitarif() RLM Custom HT/NT window
gas() Gas Single total (m³ → kWh_Hs, no tariff split)

SLP/RLM/iMSys classification

pub fn classify_messtyp(
    malo: &MaloId,
    jahresverbrauch_kwh: Decimal,
    sparte: Sparte,
) -> Messtyp
Messtyp Criteria Basis
Slp < 100 MWh/a (Strom) or < 1.500 MWh/a (Gas) §3 MessZV
Rlm ≥ 100 MWh/a (Strom) or ≥ 1.500 MWh/a (Gas) §4 MessZV
Imsys Pflichteinbau iMSys (§41a EnWG) §41a EnWG

Mehr-/Mindermengensaldo

pub fn compute_imbalance(
    forecast_kwh: Decimal,
    actual_kwh: Decimal,
) -> ImbalanceResult

ImbalanceResult contains delta_kwh and delta_pct. Positive = Mehrmenge (actual > forecast); negative = Mindermenge. Basis: §27 MessZV.


Hampel-filter quality scoring

score_intervals runs a Hampel filter over a time-ordered slice of intervals and returns per-interval QualityGrades:

pub fn score_intervals(
    intervals: &[MeterInterval],
    window_k: usize,   // half-window size (default: 3)
    threshold: f64,    // MAD threshold in sigma units (default: 3.0)
) -> Vec<QualityGrade>

QualityGrade

Grade Meaning Effect in edmd
A Clean — within threshold Billing proceeds normally
B Slightly suspicious Logged; billing proceeds
C Likely outlier de.edmd.reading.quality.warning CloudEvent emitted
F Severe outlier / substituted Billing run blocked; operator alert

hampel_filter is also exposed as a low-level primitive that returns raw outlier indices.


§17 MessZV substitute value generation

When meter readings are missing or faulty, the MSB must supply substitute values before billing. metering implements all four methods from §17 MessZV and BDEW practice.

Quick usage

use metering::{fill_gaps, fill_gaps_with_config, FillGapsConfig, SubstituteMethod};

// Automatic method selection (linear for short gaps, carry-forward for long)
let filled = fill_gaps(&intervals, 900, period_from, period_to);

// Prior-period averaging per §17 Abs. 2 MessZV (same time-slot, prior week)
let prior_week: Vec<MeterInterval> = fetch_prior_week(&malo_id);
let filled = fill_gaps_with_config(
    &intervals, 900, period_from, period_to,
    &FillGapsConfig::prior_period(prior_week),
);

SubstituteMethod variants

Variant When to use BDEW recommendation
LinearInterpolation Short gaps (≤ 3 intervals) with surrounding data Primary for RLM/iMSys
PriorPeriodAverage Longer gaps; same time-slot from prior reference week Biomass, industrial load
ZeroFill Documented plant shutdown — affirmative zero only Outage with evidence
LastValueCarryForward Conservative fallback when no context available SLP, default for longer gaps

FillGapsConfig

pub struct FillGapsConfig {
    pub method: SubstituteMethod,            // default: LinearInterpolation
    pub prior_period_intervals: Vec<MeterInterval>, // for PriorPeriodAverage
    pub short_gap_threshold: usize,          // default: 3 (auto-linear below this)
}

FillGapsConfig::prior_period(prior_week_intervals) and FillGapsConfig::zero_fill() are convenience constructors.

Filled intervals carry quality = QualityFlag::Substituted (billable per §17 MessZV Abs. 1).


Feature flags

Flag Effect
serde Derive Serialize/Deserialize on all public types

Testing

cargo test -p metering --all-features

37 tests covering gas conversion, aggregation (RLM/SLP/Gas), Messtyp classification, imbalance arithmetic, Hampel filter edge cases, and §17 MessZV substitute value generation (all four methods including PriorPeriodAverage).


Regulatory basis

  • §3, §4 MessZV — SLP/RLM classification thresholds
  • §2 Nr. 17 MessZV — Spitzenleistung definition for RLM
  • §17 MessZV — Ersatzwertbildung (substitute value generation)
  • §27 MessZV — Mehr-/Mindermengensaldo
  • §24 GasGVV / DVGW G 685 — Gas Brennwertkorrektur
  • §41a EnWG — 15-Minuten-Lastgang and iMSys Pflichteinbau