metering
**German energy metering domain library — interval types, gas conversion, billing period aggregation, SLP/RLM/iMSys classification, BSI TR-03109 SMGW lifecycle, virtual meters (§42b EnWG GGV Solarpaket I), resampling, forecasting, and Hampel-filter quality scoring.
214 tests · zero I/O · no async · no float money**
metering is the pure domain library used by edmd,
mako-gabi-gas, and mako-mabis for all
metering arithmetic. It has no I/O, no async, and no floating-point money.
Modules at a glance
| Module | Key types | Purpose |
|---|---|---|
interval |
MeterInterval, QualityFlag, Sparte |
Core interval + quality types |
obis |
ObisCode |
Typed OBIS codes (IEC 62056-21 / BDEW) with default_resolution() |
validation |
ValidationEngine, ValidationIssue (V01–V10) |
Gap / overlap / spike / DST / rollover detection |
substitute |
fill_gaps(), SubstituteMethod, SubstitutionReason |
§17 MessZV Ersatzwertbildung |
forecast |
project_annual_consumption(), prior_period_substitutes() |
§17 MessZV Jahresprognose + §17 Abs. 2 prior-period gap-fill |
resample |
resample(), ResampledBucket |
Down-sample 15-min → hourly / daily / monthly |
virtual_meter |
compute_virtual_meter(), AggregationRule |
§42b EnWG GGV: GgvConstantAllocation (CCI+ZG6) + GgvProportionalAllocation (variable); Residuallast (§42a) |
smgw |
SmgwSession, ClsChannel, GatewayCertificate |
BSI TR-03109 gateway lifecycle, §14a CLS channels |
measurement_point |
MeasurementPoint, MarktRolle, EnergyFlow |
MaLo + MeLo + OBIS + role binding |
measurement_series |
MeasurementSeries, MeasurementSource, ProvenanceEntry |
§22 MessZV provenance / explainability |
register |
MeterRegister, EnergyDirection, RegisterUnit |
HT/NT register + Wandlerfaktor metadata |
aggregation |
aggregate(), BillingPeriod, HtNtSplit |
§2 Nr. 17 MessZV Spitzenleistung + HT/NT |
classification |
classify_messtyp(), Messtyp |
SLP/RLM/iMSys (§3/§4 MessZV, §41a EnWG) |
quality |
score_intervals(), QualityGrade |
Hampel-filter quality scoring (A/B/C/F) |
demand |
DemandWindow, DemandInterval |
15-min demand / Spitzenleistung |
tariff_window |
TariffWindow, HtNtSchedule |
DST-aware HT/NT window classification |
load_profile |
LoadProfile |
German SLP load profile types (H0/G0–G6/L0–L2 …) |
conversion |
gas_m3_to_kwh_hs(), GasConversionParams |
§24 GasGVV / DVGW G 685 |
imbalance |
compute_imbalance(), ImbalanceSaldo |
§27 MessZV Mehr-/Mindermengensaldo |
resolution |
IntervalResolution |
Typed interval lengths (15-min / hourly / daily …) |
lifecycle |
MeterExchangeEvent, MeterStatus |
WiM meter exchange domain events |
Design constraints
| Constraint | Detail |
|---|---|
| No I/O | All inputs are passed as arguments. |
| No async | Synchronous throughout. |
| No float money | All energy amounts use rust_decimal::Decimal. |
| Deterministic | Same inputs always produce the same output. |
Core types
MeterInterval
A single timestamped energy reading:
QualityFlag (8 variants)
| Variant | Billable | Description |
|---|---|---|
Measured |
✅ | Direct meter reading |
Estimated |
✅ | Prognosewert (valid for Abschlag per §17 MessZV) |
Substituted |
✅ | §17 MessZV Ersatzwert |
Calculated |
✅ | Derived (e.g. Residuallast) |
Corrected |
✅ | Retroactive correction |
Preliminary |
✅ | Vorläufiger Wert |
Faulty |
❌ | Must not be billed |
Unknown |
❌ | Quality not determinable |
Gas conversion: m³ → kWh_Hs
Implements the Brennwertkorrektur formula per §24 GasGVV / DVGW G 685:
// kWh_Hs = m³ × Hs × Z (rounded to 6 dp)
let kwh = gas_m3_to_kwh_hs;
Validation engine (V01–V10)
let result = validate_intervals;
println!;
println!;
| Rule | ID | Detects |
|---|---|---|
| Gap detected | V01 | Missing intervals between adjacent reads |
| Overlap detected | V02 | Two intervals covering the same timestamp |
| Negative energy | V03 | value_kwh < 0 for import registers |
| Impossible spike | V04 | value_kwh > spike_factor × window_median |
| Suspicious zero run | V05 | Long sequence of zero values |
| Inconsistent interval | V06 | Mixed 15-min and 60-min in same series |
| DST ambiguity | V07 | Potential local-time leak at CEST→CET fall-back |
| Future timestamp | V08 | from > now |
| Non-billable quality | V09 | Faulty or Unknown intervals in billing window |
| Register rollover | V10 | Counter reset without meter-exchange event |
§17 MessZV substitute value generation
// Automatic: linear for short gaps, carry-forward for long
let filled = fill_gaps;
// Prior-period averaging per §17 Abs. 2 MessZV
let filled = fill_gaps_with_config;
// Annual forecast (Jahresprognose)
let forecast = project_annual_consumption?;
println!;
SubstituteMethod |
When to use |
|---|---|
LinearInterpolation |
Short gaps (≤ 3 intervals) with surrounding data |
PriorPeriodAverage |
Same time-slot from prior reference week (§17 Abs. 2) |
ZeroFill |
Documented plant shutdown — affirmative zero only |
LastValueCarryForward |
Conservative fallback |
Resampling
// Down-sample 15-min RLM data to monthly totals (for MaBiS §27 MessZV)
let monthly = resample;
for bucket in &monthly
Virtual meters (§42b EnWG GGV — Solarpaket I)
Both GGV variants compute the tenant's net grid draw after PV allocation,
satisfying §42b Abs. 5 EnWG sentence 2: the allocated PV energy can never exceed
the tenant's actual consumption in any 15-minute interval. This is enforced by the
Pos() = max(0, x) operator per the BDEW "Anwendungshilfe Berechnungsformeln
Solarpaket 1" (v1.0, 25.01.2024).
Formula overview
Constant allocation (BDEW Beispiel 1 — UTILTS CCI+ZG6):
net_grid_draw_i[t] = max(0, tenant_consumption_i[t] - fraction_i × plant_generation[t])
Proportional allocation (BDEW Beispiel 3 — variable ratio):
ratio_i[t] = tenant_consumption_i[t] / Σ all_tenant_consumption_j[t]
(0 if denominator = 0 — zero-division protected)
net_grid_draw_i[t] = max(0, tenant_consumption_i[t] - ratio_i[t] × plant_generation[t])
Constant allocation (Beispiel 1 — UTILTS CCI+ZG6)
// Tenant receives 10 % of plant generation; result = net grid draw
let rule = GgvConstantAllocation ;
let net_grid_draw = compute_virtual_meter?;
// Each interval: max(0, tenant_consumption - 0.10 × plant_generation)
// Examples:
// gen=10, consumption=5 → max(0, 5 - 1) = 4 (1 kWh covered by PV)
// gen=10, consumption=0.5 → max(0, 0.5 - 1) = 0 (§42b cap: no negative draw)
Proportional allocation (Beispiel 3 — variable ratio)
let rule = GgvProportionalAllocation ;
let net_grid_draw = compute_virtual_meter?;
// ratio = T2_consumption / (T2 + T3); net = max(0, T2 - ratio × generation)
// zero-division protected: if all consumptions are 0 → net = 0
Energy balance check (plant feed-in)
The residual plant feed-in (grid export from PV) equals:
plant_feedin[t] = plant_generation[t] - Σ (tenant_consumption_i[t] - net_grid_draw_i[t])
= plant_generation[t] - Σ pv_allocated_i[t]
Available rules: Sum, Residual (§42a EEG), PvSelfConsumption,
GgvConstantAllocation, GgvProportionalAllocation (§42b EnWG Solarpaket I).
BSI TR-03109 SMGW lifecycle
let session = SmgwSession ;
// Certificate expiry (BSI TR-03109-4 §6.3 — renew ≥ 30 days before expiry)
let expiring = session.expiring_certificates;
// §14a CLS channel compliance
assert!;
// Communication fault detection (triggers §17 MessZV substitute)
if session.is_communication_fault
Billing period aggregation
let agg = aggregate;
println!;
println!;
println!;
println!;
AggregationConfig presets
| Preset | Messtyp | Detail |
|---|---|---|
rlm_strom() |
RLM | Spitzenleistung §2 Nr. 17 MessZV + DST-aware HT/NT |
slp_strom() |
SLP | HT/NT split only |
rlm_zweitarif() |
RLM | Custom HT/NT window |
gas() |
Gas | Single total (m³ → kWh_Hs, no tariff split) |
Feature flags
| Flag | Effect |
|---|---|
serde |
Derive Serialize/Deserialize on all public types |
Testing
214 tests covering: gas conversion (DVGW G 685), aggregation (RLM/SLP/Gas), Messtyp classification, imbalance arithmetic, V01–V10 validation engine (incl. DST transitions and V07 DST ambiguity), §17 MessZV substitute methods, resampling (hourly/daily/monthly), §42b EnWG GGV virtual meters (Beispiel 1 constant + Beispiel 3 proportional, Pos() cap, zero-division guard), §42a Residuallast, BSI TR-03109 SMGW + CLS lifecycle, measurement series provenance, register + ObisCode.
Regulatory basis
- §3, §4 MessZV — SLP/RLM classification thresholds
- §2 Nr. 17 MessZV — Spitzenleistung definition for RLM
- §17 MessZV — Ersatzwertbildung + Jahresprognose (substitute values + annual forecast)
- §22 MessZV — 3-year provenance retention (
MeasurementSeries,ProvenanceEntry) - §27 MessZV — Mehr-/Mindermengensaldo
- §24 GasGVV / DVGW G 685 — Gas Brennwertkorrektur
- §41a EnWG — 15-Minuten-Lastgang and iMSys Pflichteinbau
- §42a/§42b EEG — Residuallast / GGV community solar virtual meters
- §14a EnWG — Steuerbare Verbrauchseinrichtungen (CLS channels)
- BSI TR-03109 — Smart Meter Gateway lifecycle and certificates
Design constraints
| Constraint | Detail |
|---|---|
| No I/O | All inputs are passed as arguments. |
| No async | Synchronous throughout. |
| No float money | All energy amounts use rust_decimal. |
| Deterministic | Same inputs always produce the same output. |
Core types
MeterInterval
A single timestamped energy reading:
Sparte
QualityFlag
Measured, Substituted, Estimated, Invalid — mapped to MSCONS/UTILTS
Datenqualitätskennzeichen.
Gas conversion: m³ → kWh_Hs
Implements the Brennwertkorrektur formula per §24 GasGVV / DVGW G 685:
$$kWh_{Hs} = m^3 \times z \times H_s$$
Billing period aggregation
aggregate computes a BillingPeriodAggregate from a slice of MeterIntervals:
let agg = aggregate?;
println!;
println!;
println!;
AggregationConfig presets
| Preset | Messtyp | Split |
|---|---|---|
rlm_strom() |
RLM | Spitzenleistung §2 Nr. 17 MessZV + HT/NT split |
slp_strom() |
SLP | HT/NT split (no Spitzenleistung) |
rlm_zweitarif() |
RLM | Custom HT/NT window |
gas() |
Gas | Single total (m³ → kWh_Hs, no tariff split) |
SLP/RLM/iMSys classification
Messtyp |
Criteria | Basis |
|---|---|---|
Slp |
< 100 MWh/a (Strom) or < 1.500 MWh/a (Gas) | §3 MessZV |
Rlm |
≥ 100 MWh/a (Strom) or ≥ 1.500 MWh/a (Gas) | §4 MessZV |
Imsys |
Pflichteinbau iMSys (§41a EnWG) | §41a EnWG |
Mehr-/Mindermengensaldo
ImbalanceResult contains delta_kwh and delta_pct.
Positive = Mehrmenge (actual > forecast); negative = Mindermenge.
Basis: §27 MessZV.
Hampel-filter quality scoring
score_intervals runs a Hampel filter over a time-ordered slice of intervals
and returns per-interval QualityGrades:
QualityGrade
| Grade | Meaning | Effect in edmd |
|---|---|---|
A |
Clean — within threshold | Billing proceeds normally |
B |
Slightly suspicious | Logged; billing proceeds |
C |
Likely outlier | de.edmd.reading.quality.warning CloudEvent emitted |
F |
Severe outlier / substituted | Billing run blocked; operator alert |
hampel_filter is also exposed as a low-level primitive that returns raw
outlier indices.
§17 MessZV substitute value generation
When meter readings are missing or faulty, the MSB must supply substitute values
before billing. metering implements all four methods from §17 MessZV and BDEW
practice.
Quick usage
use ;
// Automatic method selection (linear for short gaps, carry-forward for long)
let filled = fill_gaps;
// Prior-period averaging per §17 Abs. 2 MessZV (same time-slot, prior week)
let prior_week: = fetch_prior_week;
let filled = fill_gaps_with_config;
SubstituteMethod variants
| Variant | When to use | BDEW recommendation |
|---|---|---|
LinearInterpolation |
Short gaps (≤ 3 intervals) with surrounding data | Primary for RLM/iMSys |
PriorPeriodAverage |
Longer gaps; same time-slot from prior reference week | Biomass, industrial load |
ZeroFill |
Documented plant shutdown — affirmative zero only | Outage with evidence |
LastValueCarryForward |
Conservative fallback when no context available | SLP, default for longer gaps |
FillGapsConfig
FillGapsConfig::prior_period(prior_week_intervals) and
FillGapsConfig::zero_fill() are convenience constructors.
Filled intervals carry quality = QualityFlag::Substituted
(billable per §17 MessZV Abs. 1).
Feature flags
| Flag | Effect |
|---|---|
serde |
Derive Serialize/Deserialize on all public types |
Testing
37 tests covering gas conversion, aggregation (RLM/SLP/Gas), Messtyp
classification, imbalance arithmetic, Hampel filter edge cases, and §17 MessZV
substitute value generation (all four methods including PriorPeriodAverage).
Regulatory basis
- §3, §4 MessZV — SLP/RLM classification thresholds
- §2 Nr. 17 MessZV — Spitzenleistung definition for RLM
- §17 MessZV — Ersatzwertbildung (substitute value generation)
- §27 MessZV — Mehr-/Mindermengensaldo
- §24 GasGVV / DVGW G 685 — Gas Brennwertkorrektur
- §41a EnWG — 15-Minuten-Lastgang and iMSys Pflichteinbau