Expand description
Access: No wait states, except if a write access occurs while a write access to this register is ongoing. In this case, wait states are inserted in the second write access until the previous one is completed. The latency of the second write access can be up to 2 x PCLK1 + 6 x I2CCLK.
Structs
Register
TIMEOUTR readerAccess: No wait states, except if a write access occurs while a write access to this register is ongoing. In this case, wait states are inserted in the second write access until the previous one is completed. The latency of the second write access can be up to 2 x PCLK1 + 6 x I2CCLK.
Register
TIMEOUTR writerEnums
Extended clock timeout enable
Idle clock timeout detection Note: This bit can be written only when TIMOUTEN=0.
Clock timeout enable
Type Definitions
Field
TEXTEN reader - Extended clock timeout enableField
TEXTEN writer - Extended clock timeout enableField
TIDLE reader - Idle clock timeout detection Note: This bit can be written only when TIMOUTEN=0.Field
TIDLE writer - Idle clock timeout detection Note: This bit can be written only when TIMOUTEN=0.Field
TIMEOUTA reader - Bus Timeout A This field is used to configure: The SCL low timeout condition tTIMEOUT when TIDLE=0 tTIMEOUT= (TIMEOUTA+1) x 2048 x tI2CCLK The bus idle condition (both SCL and SDA high) when TIDLE=1 tIDLE= (TIMEOUTA+1) x 4 x tI2CCLK Note: These bits can be written only when TIMOUTEN=0.Field
TIMEOUTA writer - Bus Timeout A This field is used to configure: The SCL low timeout condition tTIMEOUT when TIDLE=0 tTIMEOUT= (TIMEOUTA+1) x 2048 x tI2CCLK The bus idle condition (both SCL and SDA high) when TIDLE=1 tIDLE= (TIMEOUTA+1) x 4 x tI2CCLK Note: These bits can be written only when TIMOUTEN=0.Field
TIMEOUTB reader - Bus timeout B This field is used to configure the cumulative clock extension timeout: In master mode, the master cumulative clock low extend time (tLOW:MEXT) is detected In slave mode, the slave cumulative clock low extend time (tLOW:SEXT) is detected tLOW:EXT= (TIMEOUTB+1) x 2048 x tI2CCLK Note: These bits can be written only when TEXTEN=0.Field
TIMEOUTB writer - Bus timeout B This field is used to configure the cumulative clock extension timeout: In master mode, the master cumulative clock low extend time (tLOW:MEXT) is detected In slave mode, the slave cumulative clock low extend time (tLOW:SEXT) is detected tLOW:EXT= (TIMEOUTB+1) x 2048 x tI2CCLK Note: These bits can be written only when TEXTEN=0.Field
TIMOUTEN reader - Clock timeout enableField
TIMOUTEN writer - Clock timeout enable