voltage_modbus 0.6.1

A high-performance industrial Modbus library for Rust with TCP and RTU support
docs.rs failed to build voltage_modbus-0.6.1
Please check the build logs for more information.
See Builds for ideas on how to fix a failed build, or Metadata for how to configure docs.rs builds.
If you believe this is docs.rs' fault, open an issue.
Visit the last successful build: voltage_modbus-0.5.1

Voltage Modbus

Crates.io docs.rs Rust License: MIT

High-performance Modbus TCP/RTU library for Rust, designed for industrial automation and IoT applications.

Why voltage_modbus?

Feature voltage_modbus tokio-modbus
Request pipelining Yes — N requests in ~1 RTT No — strictly sequential
Read coalescing Yes — auto-merge adjacent reads No
Zero-alloc hot path Yes — stack frames, persistent buffers No — per-request heap alloc
TCP_NODELAY Yes — eliminates Nagle delay No
Broadcast (slave=0) Yes — no-timeout write Triggers timeout error
no_std core Yes — PDU/protocol/error No
Auto reconnection Yes No
Float/multi-register codec Yes — f32/f64/i32 with byte order No
Async trait RPITIT (zero-cost) async-trait (Box alloc)

Features

  • Request pipelining — send multiple requests in a single write, match responses by Transaction ID
  • Read coalescing — automatically merge adjacent register reads to minimize network round-trips
  • Zero-alloc hot path — stack-allocated frames, persistent read buffers, no per-request heap allocation
  • Modbus TCP and RTU — generic client architecture, shared PDU logic
  • no_std support — core modules (PDU, protocol, error, constants) work without std
  • Broadcast support — slave_id=0 write operations return immediately without waiting for response
  • Zero unsafe code — pure safe Rust
  • Async/await — built on Tokio with zero-cost async traits (RPITIT)

Installation

cargo add voltage_modbus

For RTU (serial) support:

voltage_modbus = { version = "0.5", features = ["rtu"] }

For no_std (PDU encoding/decoding only):

voltage_modbus = { version = "0.5", default-features = false }

Quick Start

TCP Client

use voltage_modbus::{ModbusTcpClient, ModbusClient, ModbusResult};
use std::time::Duration;

#[tokio::main]
async fn main() -> ModbusResult<()> {
    let mut client = ModbusTcpClient::from_address("127.0.0.1:502", Duration::from_secs(5)).await?;

    // Read holding registers
    let values = client.read_03(1, 0, 10).await?;
    println!("Registers: {:?}", values);

    // Write single register
    client.write_06(1, 100, 0x1234).await?;

    client.close().await?;
    Ok(())
}

RTU Client

use voltage_modbus::{ModbusRtuClient, ModbusClient, ModbusResult};
use std::time::Duration;

#[tokio::main]
async fn main() -> ModbusResult<()> {
    let mut client = ModbusRtuClient::new("/dev/ttyUSB0", 9600)?;

    let coils = client.read_01(1, 0, 8).await?;
    println!("Coils: {:?}", coils);

    client.close().await?;
    Ok(())
}

Pipelining — N Requests in ~1 RTT

use voltage_modbus::{ModbusTcpClient, ModbusResult};
use std::time::Duration;

#[tokio::main]
async fn main() -> ModbusResult<()> {
    let mut client = ModbusTcpClient::from_address("127.0.0.1:502", Duration::from_secs(5)).await?;

    // Read 3 different register regions in a single network round-trip
    let results = client.pipeline_reads(1, &[
        (0, 10),    // registers 0-9
        (100, 5),   // registers 100-104
        (200, 3),   // registers 200-202
    ], Duration::from_secs(5)).await?;

    for (i, result) in results.iter().enumerate() {
        match result {
            Ok(regs) => println!("Region {}: {:?}", i, regs),
            Err(e) => println!("Region {} failed: {}", i, e),
        }
    }

    client.close().await?;
    Ok(())
}

Read Coalescing — Auto-merge Adjacent Reads

use voltage_modbus::{ModbusTcpClient, ModbusClient, ModbusResult};
use std::time::Duration;

#[tokio::main]
async fn main() -> ModbusResult<()> {
    let mut client = ModbusTcpClient::from_address("127.0.0.1:502", Duration::from_secs(5)).await?;

    // These 3 regions are close together — the library automatically merges them
    // into fewer network requests based on a configurable gap threshold
    let results = client.read_holding_registers_coalesced(1, &[
        (0, 2),    // temperature (registers 0-1)
        (2, 2),    // pressure (registers 2-3)
        (10, 2),   // flow rate (registers 10-11)
    ]).await?;

    // Results are returned in the original order
    println!("Temperature regs: {:?}", results[0]);
    println!("Pressure regs: {:?}", results[1]);
    println!("Flow rate regs: {:?}", results[2]);

    client.close().await?;
    Ok(())
}

Supported Function Codes

Code Function Method
0x01 Read Coils read_01() / read_coils()
0x02 Read Discrete Inputs read_02() / read_discrete_inputs()
0x03 Read Holding Registers read_03() / read_holding_registers()
0x04 Read Input Registers read_04() / read_input_registers()
0x05 Write Single Coil write_05() / write_single_coil()
0x06 Write Single Register write_06() / write_single_register()
0x0F Write Multiple Coils write_0f() / write_multiple_coils()
0x10 Write Multiple Registers write_10() / write_multiple_registers()

Architecture

┌───────────────────────────────────────────────┐
│             Application Layer                 │
│                                               │
│  ┌──────────────────┐  ┌─────────────────┐    │
│  │ ModbusTcpClient  │  │ ModbusRtuClient │    │
│  │  + pipeline()    │  └────────┬────────┘    │
│  │  + coalesced()   │           │             │
│  └────────┬─────────┘           │             │
│           │─────────────────────┘             │
│  ┌────────┴──────────────────┐                │
│  │    GenericModbusClient    │                │
│  │     (Shared PDU Logic)    │                │
│  └───────────────────────────┘                │
└───────────────────────────────────────────────┘
┌───────────────────────────────────────────────┐
│             Transport Layer                   │
│                                               │
│  ┌─────────────────┐  ┌─────────────────┐     │
│  │  TcpTransport   │  │  RtuTransport   │     │
│  │  TCP_NODELAY    │  │  CRC-16         │     │
│  │  zero-alloc I/O │  │  frame gap      │     │
│  └─────────────────┘  └─────────────────┘     │
└───────────────────────────────────────────────┘
┌───────────────────────────────────────────────┐
│        Core (no_std compatible)               │
│                                               │
│  ModbusPdu · ModbusFunction · ModbusError     │
│  constants · protocol · CRC                   │
└───────────────────────────────────────────────┘

TCP and RTU share identical PDU (Protocol Data Unit), differing only in transport framing.