1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
{
"group": {
"desc": "DER Watt-Var model.",
"groups": [
{
"comments": [
"Stored curve sets - Number of curve sets contained in NCrv - The first set is read-only and indicates the current settings."
],
"count": "NCrv",
"desc": "Stored curve sets.",
"groups": [
{
"comments": [
"Stored curve sets - curve points for each stored curve - Number of curve points contained in NPt"
],
"count": "NPt",
"desc": "Stored curve points.",
"label": "Stored Curve Points",
"name": "Pt",
"points": [
{
"access": "RW",
"desc": "Curve active power point as percentage.",
"label": "Active Power Point",
"name": "W",
"sf": "W_SF",
"size": 1,
"type": "int16",
"units": "WMaxPct",
"standards": [
"IEEE 1547-2018"
],
"detail": "Internal curve conformance checks should be conducted when AdptCrvReq is set to 1, not on point writes. IEEE 1547 implementations must allow 0 values for all three load points."
},
{
"access": "RW",
"desc": "Curve reactive power point as set in DeptRef point.",
"label": "Reactive Power Point",
"name": "Var",
"sf": "DeptRef_SF",
"size": 1,
"type": "int16",
"units": "VarPct",
"standards": [
"IEEE 1547-2018"
],
"detail": "Internal curve conformance checks should be conducted when AdptCrvReq is set to 1, not on point writes. IEEE 1547 implementations must allow 0 values for all three load points"
}
],
"type": "group"
}
],
"label": "Stored Curves",
"name": "Crv",
"points": [
{
"access": "RW",
"desc": "Number of active points.",
"label": "Active Points",
"mandatory": "M",
"name": "ActPt",
"size": 1,
"type": "uint16",
"standards": [
"IEEE 1547-2018"
]
},
{
"access": "RW",
"desc": "Curve dependent reference.",
"label": "Dependent Reference",
"mandatory": "M",
"name": "DeptRef",
"size": 1,
"symbols": [
{
"label": "Percent Max Watts",
"name": "W_MAX_PCT",
"value": 0
},
{
"label": "Percent Max Vars",
"name": "VAR_MAX_PCT",
"value": 1
},
{
"label": "Percent Available Vars",
"name": "VAR_AVAL_PCT",
"value": 2
},
{
"label": "Percent Max Apparent Power",
"name": "VA_MAX_PCT",
"value": 3
}
],
"type": "enum16",
"standards": [
"IEEE 1547-2018"
]
},
{
"access": "RW",
"desc": "Power priority.",
"label": "Power Priority",
"name": "Pri",
"size": 1,
"symbols": [
{
"desc": "Active power priority.",
"label": "Active Power Priority",
"name": "ACTIVE",
"value": 0
},
{
"desc": "Reactive power priority.",
"label": "Reactive Power Priority",
"name": "REACTIVE",
"value": 1
}
],
"type": "enum16",
"standards": [
"IEEE 1547-2018"
]
},
{
"desc": "Curve read-write access.",
"label": "Curve Access",
"mandatory": "M",
"name": "ReadOnly",
"size": 1,
"static": "S",
"symbols": [
{
"desc": "Curve has read-write access.",
"label": "Read-Write Access",
"name": "RW",
"value": 0
},
{
"desc": "Curve has read-only access.",
"label": "Read-Only Access",
"name": "R",
"value": 1
}
],
"type": "enum16",
"standards": [
"IEEE 1547-2018"
]
}
],
"type": "group"
}
],
"label": "DER Watt-Var",
"name": "DERWattVar",
"points": [
{
"desc": "DER Watt-Var model ID.",
"label": "Model ID",
"mandatory": "M",
"name": "ID",
"size": 1,
"static": "S",
"type": "uint16",
"value": 712,
"standards": [
"IEEE 1547-2018"
]
},
{
"desc": "DER Watt-Var model length.",
"label": "Model Length",
"mandatory": "M",
"name": "L",
"size": 1,
"static": "S",
"type": "uint16",
"standards": [
"IEEE 1547-2018"
]
},
{
"access": "RW",
"desc": "DER Watt-Var control enable.",
"label": "DER Watt-Var Module Enable",
"mandatory": "M",
"name": "Ena",
"size": 1,
"symbols": [
{
"desc": "Function is disabled.",
"label": "Disabled",
"name": "DISABLED",
"value": 0
},
{
"desc": "Function is enabled.",
"label": "Enabled",
"name": "ENABLED",
"value": 1
}
],
"type": "enum16",
"standards": [
"IEEE 1547-2018"
]
},
{
"access": "RW",
"desc": "Set active curve. 0 = No active curve.",
"label": "Set Active Curve Request",
"mandatory": "M",
"name": "AdptCrvReq",
"size": 1,
"type": "uint16",
"standards": [
"IEEE 1547-2018"
]
},
{
"desc": "Result of last set active curve operation.",
"label": "Set Active Curve Result",
"mandatory": "M",
"name": "AdptCrvRslt",
"size": 1,
"symbols": [
{
"desc": "Curve update in progress.",
"label": "Update In Progress",
"name": "IN_PROGRESS",
"value": 0
},
{
"desc": "Curve update completed successfully.",
"label": "Update Complete",
"name": "COMPLETED",
"value": 1
},
{
"desc": "Curve update failed.",
"label": "Update Failed",
"name": "FAILED",
"value": 2
}
],
"type": "enum16",
"standards": [
"IEEE 1547-2018"
]
},
{
"desc": "Number of curve points supported.",
"label": "Number Of Points",
"mandatory": "M",
"name": "NPt",
"size": 1,
"static": "S",
"type": "uint16",
"standards": [
"IEEE 1547-2018"
]
},
{
"desc": "Number of stored curves supported.",
"label": "Stored Curve Count",
"mandatory": "M",
"name": "NCrv",
"size": 1,
"static": "S",
"type": "uint16",
"standards": [
"IEEE 1547-2018"
]
},
{
"access": "RW",
"desc": "Reversion time in seconds. 0 = No reversion time.",
"label": "Reversion Timeout",
"name": "RvrtTms",
"size": 2,
"type": "uint32",
"units": "Secs",
"standards": []
},
{
"desc": "Reversion time remaining in seconds.",
"label": "Reversion Time Left",
"name": "RvrtRem",
"size": 2,
"type": "uint32",
"units": "Secs",
"standards": []
},
{
"access": "RW",
"desc": "Default curve after reversion timeout.",
"label": "Reversion Curve",
"name": "RvrtCrv",
"size": 1,
"type": "uint16",
"standards": []
},
{
"desc": "Scale factor for curve active power points.",
"label": "Active Power Scale Factor",
"mandatory": "M",
"name": "W_SF",
"size": 1,
"static": "S",
"type": "sunssf",
"standards": [
"IEEE 1547-2018"
]
},
{
"desc": "Scale factor for curve var points.",
"label": "Var Scale Factor",
"mandatory": "M",
"name": "DeptRef_SF",
"size": 1,
"static": "S",
"type": "sunssf",
"standards": [
"IEEE 1547-2018"
]
}
],
"type": "group"
},
"id": 712
}