pub struct R<U, T> { /* private fields */ }
Expand description
Register/field reader
Result of the read
method of a register.
Also it can be used in the modify
method
Read raw bits from register/field
Value of the field as raw bits
Returns true
if the bit is clear (0)
Returns true
if the bit is set (1)
Bit 0 - Watchdog Interrupt Enable
Bit 1 - Watchdog Reset Enable
Bit 2 - Watchdog Interrupt Type
Bit 0 - Watchdog Raw Interrupt Status
Bit 0 - Watchdog Masked Interrupt Status
Bit 8 - Watchdog Stall Enable
Get enumerated values variant
Checks if the value of the field is UNLOCKED
Checks if the value of the field is LOCKED
Checks if the value of the field is UNLOCK
Bits 0:31 - Watchdog Lock
Bits 0:7 - GPIO Interrupt Mask Enable
Bits 0:7 - GPIO Interrupt Raw Status
Bits 0:7 - GPIO Masked Interrupt Status
Get enumerated values variant
Checks if the value of the field is UNLOCKED
Checks if the value of the field is LOCKED
Checks if the value of the field is KEY
Get enumerated values variant
Checks if the value of the field is _4
Checks if the value of the field is _5
Checks if the value of the field is _6
Checks if the value of the field is _7
Checks if the value of the field is _8
Checks if the value of the field is _9
Checks if the value of the field is _10
Checks if the value of the field is _11
Checks if the value of the field is _12
Checks if the value of the field is _13
Checks if the value of the field is _14
Checks if the value of the field is _15
Checks if the value of the field is _16
Get enumerated values variant
Checks if the value of the field is MOTO
Checks if the value of the field is TI
Checks if the value of the field is NMW
Bits 0:3 - SSI Data Size Select
Bits 4:5 - SSI Frame Format Select
Bit 6 - SSI Serial Clock Polarity
Bit 7 - SSI Serial Clock Phase
Bits 8:15 - SSI Serial Clock Rate
Bit 0 - SSI Loopback Mode
Bit 1 - SSI Synchronous Serial Port Enable
Bit 2 - SSI Master/Slave Select
Bit 4 - End of Transmission
Bits 0:15 - SSI Receive/Transmit Data
Bit 0 - SSI Transmit FIFO Empty
Bit 1 - SSI Transmit FIFO Not Full
Bit 2 - SSI Receive FIFO Not Empty
Bit 3 - SSI Receive FIFO Full
Bits 0:7 - SSI Clock Prescale Divisor
Bit 0 - SSI Receive Overrun Interrupt Mask
Bit 1 - SSI Receive Time-Out Interrupt Mask
Bit 2 - SSI Receive FIFO Interrupt Mask
Bit 3 - SSI Transmit FIFO Interrupt Mask
Bit 0 - SSI Receive Overrun Raw Interrupt Status
Bit 1 - SSI Receive Time-Out Raw Interrupt Status
Bit 2 - SSI Receive FIFO Raw Interrupt Status
Bit 3 - SSI Transmit FIFO Raw Interrupt Status
Bit 0 - SSI Receive Overrun Masked Interrupt Status
Bit 1 - SSI Receive Time-Out Masked Interrupt Status
Bit 2 - SSI Receive FIFO Masked Interrupt Status
Bit 3 - SSI Transmit FIFO Masked Interrupt Status
Bit 0 - Receive DMA Enable
Bit 1 - Transmit DMA Enable
Get enumerated values variant
Checks if the value of the field is SYSPLL
Checks if the value of the field is PIOSC
Bits 0:3 - SSI Baud Clock Source
Bits 0:7 - Data Transmitted or Received
Bit 8 - UART Framing Error
Bit 9 - UART Parity Error
Bit 10 - UART Break Error
Bit 11 - UART Overrun Error
Bit 0 - UART Framing Error
Bit 1 - UART Parity Error
Bit 3 - UART Overrun Error
Bit 4 - UART Receive FIFO Empty
Bit 5 - UART Transmit FIFO Full
Bit 6 - UART Receive FIFO Full
Bit 7 - UART Transmit FIFO Empty
Bits 0:7 - IrDA Low-Power Divisor
Bits 0:15 - Integer Baud-Rate Divisor
Bits 0:5 - Fractional Baud-Rate Divisor
Get enumerated values variant
Checks if the value of the field is _5
Checks if the value of the field is _6
Checks if the value of the field is _7
Checks if the value of the field is _8
Bit 1 - UART Parity Enable
Bit 2 - UART Even Parity Select
Bit 3 - UART Two Stop Bits Select
Bit 4 - UART Enable FIFOs
Bits 5:6 - UART Word Length
Bit 7 - UART Stick Parity Select
Bit 2 - UART SIR Low-Power Mode
Bit 3 - ISO 7816 Smart Card Support
Bit 4 - End of Transmission
Bit 5 - High-Speed Enable
Bit 7 - UART Loop Back Enable
Bit 8 - UART Transmit Enable
Bit 9 - UART Receive Enable
Bit 14 - Enable Request to Send
Bit 15 - Enable Clear To Send
Get enumerated values variant
Checks if the value of the field is TX1_8
Checks if the value of the field is TX2_8
Checks if the value of the field is TX4_8
Checks if the value of the field is TX6_8
Checks if the value of the field is TX7_8
Get enumerated values variant
Checks if the value of the field is RX1_8
Checks if the value of the field is RX2_8
Checks if the value of the field is RX4_8
Checks if the value of the field is RX6_8
Checks if the value of the field is RX7_8
Bits 0:2 - UART Transmit Interrupt FIFO Level Select
Bits 3:5 - UART Receive Interrupt FIFO Level Select
Bit 1 - UART Clear to Send Modem Interrupt Mask
Bit 4 - UART Receive Interrupt Mask
Bit 5 - UART Transmit Interrupt Mask
Bit 6 - UART Receive Time-Out Interrupt Mask
Bit 7 - UART Framing Error Interrupt Mask
Bit 8 - UART Parity Error Interrupt Mask
Bit 9 - UART Break Error Interrupt Mask
Bit 10 - UART Overrun Error Interrupt Mask
Bit 12 - 9-Bit Mode Interrupt Mask
Bit 1 - UART Clear to Send Modem Raw Interrupt Status
Bit 4 - UART Receive Raw Interrupt Status
Bit 5 - UART Transmit Raw Interrupt Status
Bit 6 - UART Receive Time-Out Raw Interrupt Status
Bit 7 - UART Framing Error Raw Interrupt Status
Bit 8 - UART Parity Error Raw Interrupt Status
Bit 9 - UART Break Error Raw Interrupt Status
Bit 10 - UART Overrun Error Raw Interrupt Status
Bit 12 - 9-Bit Mode Raw Interrupt Status
Bit 1 - UART Clear to Send Modem Masked Interrupt Status
Bit 4 - UART Receive Masked Interrupt Status
Bit 5 - UART Transmit Masked Interrupt Status
Bit 6 - UART Receive Time-Out Masked Interrupt Status
Bit 7 - UART Framing Error Masked Interrupt Status
Bit 8 - UART Parity Error Masked Interrupt Status
Bit 9 - UART Break Error Masked Interrupt Status
Bit 10 - UART Overrun Error Masked Interrupt Status
Bit 12 - 9-Bit Mode Masked Interrupt Status
Bit 0 - Receive DMA Enable
Bit 1 - Transmit DMA Enable
Bits 0:7 - Self Address for 9-Bit Mode
Bit 15 - Enable 9-Bit Mode
Bits 0:7 - Self Address Mask for 9-Bit Mode
Bit 0 - Smart Card Support
Get enumerated values variant
Checks if the value of the field is SYSCLK
Checks if the value of the field is PIOSC
Bits 0:3 - UART Baud Clock Source
Bits 1:7 - I2C Slave Address
Bit 0 - I2C Master Enable
Bit 2 - Acknowledge Address
Bit 3 - Data Acknowledge Enable
Bit 4 - High-Speed Enable
Bit 7 - Clock Timeout Error
Bits 0:7 - This byte contains the data transferred during a transaction
Bit 7 - High-Speed Enable
Bit 0 - Master Interrupt Mask
Bit 1 - Clock Timeout Interrupt Mask
Bit 0 - Master Raw Interrupt Status
Bit 1 - Clock Timeout Raw Interrupt Status
Bit 0 - Masked Interrupt Status
Bit 1 - Clock Timeout Masked Interrupt Status
Bit 4 - I2C Master Function Enable
Bit 5 - I2C Slave Function Enable
Bit 6 - I2C Glitch Filter Enable
Bits 0:7 - I2C Master Count
Get enumerated values variant
Checks if the value of the field is BYPASS
Checks if the value of the field is _1
Checks if the value of the field is _2
Checks if the value of the field is _3
Checks if the value of the field is _4
Checks if the value of the field is _8
Checks if the value of the field is _16
Checks if the value of the field is _31
Bits 4:6 - I2C Glitch Filter Pulse Width
Bits 0:6 - I2C Slave Own Address
Bit 2 - First Byte Received
Bit 3 - OAR2 Address Matched
Bits 0:7 - Data for Transfer
Bit 0 - Data Interrupt Mask
Bit 1 - Start Condition Interrupt Mask
Bit 2 - Stop Condition Interrupt Mask
Bit 0 - Data Raw Interrupt Status
Bit 1 - Start Condition Raw Interrupt Status
Bit 2 - Stop Condition Raw Interrupt Status
Bit 0 - Data Masked Interrupt Status
Bit 1 - Start Condition Masked Interrupt Status
Bit 2 - Stop Condition Masked Interrupt Status
Bits 0:6 - I2C Slave Own Address 2
Bit 7 - I2C Slave Own Address 2 Enable
Bit 0 - I2C Slave ACK Override Enable
Bit 1 - I2C Slave ACK Override Value
Bit 0 - High-Speed Capable
Bit 0 - High-Speed Capable
Bit 0 - Update PWM Generator 0
Bit 1 - Update PWM Generator 1
Bit 2 - Update PWM Generator 2
Bit 3 - Update PWM Generator 3
Bit 0 - Reset Generator 0 Counter
Bit 1 - Reset Generator 1 Counter
Bit 2 - Reset Generator 2 Counter
Bit 3 - Reset Generator 3 Counter
Bit 0 - MnPWM0 Output Enable
Bit 1 - MnPWM1 Output Enable
Bit 2 - MnPWM2 Output Enable
Bit 3 - MnPWM3 Output Enable
Bit 4 - MnPWM4 Output Enable
Bit 5 - MnPWM5 Output Enable
Bit 6 - MnPWM6 Output Enable
Bit 7 - MnPWM7 Output Enable
Bit 0 - Invert MnPWM0 Signal
Bit 1 - Invert MnPWM1 Signal
Bit 2 - Invert MnPWM2 Signal
Bit 3 - Invert MnPWM3 Signal
Bit 4 - Invert MnPWM4 Signal
Bit 5 - Invert MnPWM5 Signal
Bit 6 - Invert MnPWM6 Signal
Bit 7 - Invert MnPWM7 Signal
Bit 0 - PWM0 Interrupt Enable
Bit 1 - PWM1 Interrupt Enable
Bit 2 - PWM2 Interrupt Enable
Bit 3 - PWM3 Interrupt Enable
Bit 16 - Interrupt Fault 0
Bit 17 - Interrupt Fault 1
Bit 0 - PWM0 Interrupt Asserted
Bit 1 - PWM1 Interrupt Asserted
Bit 2 - PWM2 Interrupt Asserted
Bit 3 - PWM3 Interrupt Asserted
Bit 16 - Interrupt Fault PWM 0
Bit 17 - Interrupt Fault PWM 1
Bit 0 - PWM0 Interrupt Status
Bit 1 - PWM1 Interrupt Status
Bit 2 - PWM2 Interrupt Status
Bit 3 - PWM3 Interrupt Status
Bit 16 - FAULT0 Interrupt Asserted
Bit 17 - FAULT1 Interrupt Asserted
Bit 0 - Generator 0 Fault Status
Bit 1 - Generator 1 Fault Status
Bit 0 - MnPWM0 Fault Value
Bit 1 - MnPWM1 Fault Value
Bit 2 - MnPWM2 Fault Value
Bit 3 - MnPWM3 Fault Value
Bit 4 - MnPWM4 Fault Value
Bit 5 - MnPWM5 Fault Value
Bit 6 - MnPWM6 Fault Value
Bit 7 - MnPWM7 Fault Value
Get enumerated values variant
Checks if the value of the field is IMM
Checks if the value of the field is LSYNC
Checks if the value of the field is GSYNC
Get enumerated values variant
Checks if the value of the field is IMM
Checks if the value of the field is LSYNC
Checks if the value of the field is GSYNC
Get enumerated values variant
Checks if the value of the field is IMM
Checks if the value of the field is LSYNC
Checks if the value of the field is GSYNC
Get enumerated values variant
Checks if the value of the field is IMM
Checks if the value of the field is LSYNC
Checks if the value of the field is GSYNC
Get enumerated values variant
Checks if the value of the field is IMM
Checks if the value of the field is LSYNC
Checks if the value of the field is GSYNC
Get enumerated values variant
Checks if the value of the field is IMM
Checks if the value of the field is LSYNC
Checks if the value of the field is GSYNC
Get enumerated values variant
Checks if the value of the field is IMM
Checks if the value of the field is LSYNC
Checks if the value of the field is GSYNC
Get enumerated values variant
Checks if the value of the field is IMM
Checks if the value of the field is LSYNC
Checks if the value of the field is GSYNC
Bits 0:1 - MnPWM0 Enable Update Mode
Bits 2:3 - MnPWM1 Enable Update Mode
Bits 4:5 - MnPWM2 Enable Update Mode
Bits 6:7 - MnPWM3 Enable Update Mode
Bits 8:9 - MnPWM4 Enable Update Mode
Bits 10:11 - MnPWM5 Enable Update Mode
Bits 12:13 - MnPWM6 Enable Update Mode
Bits 14:15 - MnPWM7 Enable Update Mode
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Bit 3 - Load Register Update Mode
Bit 4 - Comparator A Update Mode
Bit 5 - Comparator B Update Mode
Bits 6:7 - PWMnGENA Update Mode
Bits 8:9 - PWMnGENB Update Mode
Bits 10:11 - PWMnDBCTL Update Mode
Bits 12:13 - PWMnDBRISE Update Mode
Bits 14:15 - PWMnDBFALL Update Mode
Bit 16 - Fault Condition Source
Bit 17 - Minimum Fault Period
Bit 18 - Latch Fault Input
Bit 0 - Interrupt for Counter=0
Bit 1 - Interrupt for Counter=PWMnLOAD
Bit 2 - Interrupt for Counter=PWMnCMPA Up
Bit 3 - Interrupt for Counter=PWMnCMPA Down
Bit 4 - Interrupt for Counter=PWMnCMPB Up
Bit 5 - Interrupt for Counter=PWMnCMPB Down
Bit 8 - Trigger for Counter=0
Bit 9 - Trigger for Counter=PWMnLOAD
Bit 10 - Trigger for Counter=PWMnCMPA Up
Bit 11 - Trigger for Counter=PWMnCMPA Down
Bit 12 - Trigger for Counter=PWMnCMPB Up
Bit 13 - Trigger for Counter=PWMnCMPB Down
Bit 0 - Counter=0 Interrupt Status
Bit 1 - Counter=Load Interrupt Status
Bit 2 - Comparator A Up Interrupt Status
Bit 3 - Comparator A Down Interrupt Status
Bit 4 - Comparator B Up Interrupt Status
Bit 5 - Comparator B Down Interrupt Status
Bit 0 - Counter=0 Interrupt
Bit 1 - Counter=Load Interrupt
Bit 2 - Comparator A Up Interrupt
Bit 3 - Comparator A Down Interrupt
Bit 4 - Comparator B Up Interrupt
Bit 5 - Comparator B Down Interrupt
Bits 0:15 - Counter Load Value
Bits 0:15 - Counter Value
Bits 0:15 - Comparator A Value
Bits 0:15 - Comparator B Value
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Bits 0:1 - Action for Counter=0
Bits 2:3 - Action for Counter=LOAD
Bits 4:5 - Action for Comparator A Up
Bits 6:7 - Action for Comparator A Down
Bits 8:9 - Action for Comparator B Up
Bits 10:11 - Action for Comparator B Down
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Bits 0:1 - Action for Counter=0
Bits 2:3 - Action for Counter=LOAD
Bits 4:5 - Action for Comparator A Up
Bits 6:7 - Action for Comparator A Down
Bits 8:9 - Action for Comparator B Up
Bits 10:11 - Action for Comparator B Down
Bit 0 - Dead-Band Generator Enable
Bits 0:11 - Dead-Band Rise Delay
Bits 0:11 - Dead-Band Fall Delay
Bit 0 - Digital Comparator 0
Bit 1 - Digital Comparator 1
Bit 2 - Digital Comparator 2
Bit 3 - Digital Comparator 3
Bit 4 - Digital Comparator 4
Bit 5 - Digital Comparator 5
Bit 6 - Digital Comparator 6
Bit 7 - Digital Comparator 7
Bits 0:15 - Minimum Fault Period
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Bit 3 - Load Register Update Mode
Bit 4 - Comparator A Update Mode
Bit 5 - Comparator B Update Mode
Bits 6:7 - PWMnGENA Update Mode
Bits 8:9 - PWMnGENB Update Mode
Bits 10:11 - PWMnDBCTL Update Mode
Bits 12:13 - PWMnDBRISE Update Mode
Bits 14:15 - PWMnDBFALL Update Mode
Bit 16 - Fault Condition Source
Bit 17 - Minimum Fault Period
Bit 18 - Latch Fault Input
Bit 0 - Interrupt for Counter=0
Bit 1 - Interrupt for Counter=PWMnLOAD
Bit 2 - Interrupt for Counter=PWMnCMPA Up
Bit 3 - Interrupt for Counter=PWMnCMPA Down
Bit 4 - Interrupt for Counter=PWMnCMPB Up
Bit 5 - Interrupt for Counter=PWMnCMPB Down
Bit 8 - Trigger for Counter=0
Bit 9 - Trigger for Counter=PWMnLOAD
Bit 10 - Trigger for Counter=PWMnCMPA Up
Bit 11 - Trigger for Counter=PWMnCMPA Down
Bit 12 - Trigger for Counter=PWMnCMPB Up
Bit 13 - Trigger for Counter=PWMnCMPB Down
Bit 0 - Counter=0 Interrupt Status
Bit 1 - Counter=Load Interrupt Status
Bit 2 - Comparator A Up Interrupt Status
Bit 3 - Comparator A Down Interrupt Status
Bit 4 - Comparator B Up Interrupt Status
Bit 5 - Comparator B Down Interrupt Status
Bit 0 - Counter=0 Interrupt
Bit 1 - Counter=Load Interrupt
Bit 2 - Comparator A Up Interrupt
Bit 3 - Comparator A Down Interrupt
Bit 4 - Comparator B Up Interrupt
Bit 5 - Comparator B Down Interrupt
Bits 0:15 - Counter Load Value
Bits 0:15 - Counter Value
Bits 0:15 - Comparator A Value
Bits 0:15 - Comparator B Value
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Bits 0:1 - Action for Counter=0
Bits 2:3 - Action for Counter=LOAD
Bits 4:5 - Action for Comparator A Up
Bits 6:7 - Action for Comparator A Down
Bits 8:9 - Action for Comparator B Up
Bits 10:11 - Action for Comparator B Down
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Bits 0:1 - Action for Counter=0
Bits 2:3 - Action for Counter=LOAD
Bits 4:5 - Action for Comparator A Up
Bits 6:7 - Action for Comparator A Down
Bits 8:9 - Action for Comparator B Up
Bits 10:11 - Action for Comparator B Down
Bit 0 - Dead-Band Generator Enable
Bits 0:11 - Dead-Band Rise Delay
Bits 0:11 - Dead-Band Fall Delay
Bit 0 - Digital Comparator 0
Bit 1 - Digital Comparator 1
Bit 2 - Digital Comparator 2
Bit 3 - Digital Comparator 3
Bit 4 - Digital Comparator 4
Bit 5 - Digital Comparator 5
Bit 6 - Digital Comparator 6
Bit 7 - Digital Comparator 7
Bits 0:15 - Minimum Fault Period
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Bit 3 - Load Register Update Mode
Bit 4 - Comparator A Update Mode
Bit 5 - Comparator B Update Mode
Bits 6:7 - PWMnGENA Update Mode
Bits 8:9 - PWMnGENB Update Mode
Bits 10:11 - PWMnDBCTL Update Mode
Bits 12:13 - PWMnDBRISE Update Mode
Bits 14:15 - PWMnDBFALL Update Mode
Bit 16 - Fault Condition Source
Bit 17 - Minimum Fault Period
Bit 18 - Latch Fault Input
Bit 0 - Interrupt for Counter=0
Bit 1 - Interrupt for Counter=PWMnLOAD
Bit 2 - Interrupt for Counter=PWMnCMPA Up
Bit 3 - Interrupt for Counter=PWMnCMPA Down
Bit 4 - Interrupt for Counter=PWMnCMPB Up
Bit 5 - Interrupt for Counter=PWMnCMPB Down
Bit 8 - Trigger for Counter=0
Bit 9 - Trigger for Counter=PWMnLOAD
Bit 10 - Trigger for Counter=PWMnCMPA Up
Bit 11 - Trigger for Counter=PWMnCMPA Down
Bit 12 - Trigger for Counter=PWMnCMPB Up
Bit 13 - Trigger for Counter=PWMnCMPB Down
Bit 0 - Counter=0 Interrupt Status
Bit 1 - Counter=Load Interrupt Status
Bit 2 - Comparator A Up Interrupt Status
Bit 3 - Comparator A Down Interrupt Status
Bit 4 - Comparator B Up Interrupt Status
Bit 5 - Comparator B Down Interrupt Status
Bit 0 - Counter=0 Interrupt
Bit 1 - Counter=Load Interrupt
Bit 2 - Comparator A Up Interrupt
Bit 3 - Comparator A Down Interrupt
Bit 4 - Comparator B Up Interrupt
Bit 5 - Comparator B Down Interrupt
Bits 0:15 - Counter Load Value
Bits 0:15 - Counter Value
Bits 0:15 - Comparator A Value
Bits 0:15 - Comparator B Value
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Bits 0:1 - Action for Counter=0
Bits 2:3 - Action for Counter=LOAD
Bits 4:5 - Action for Comparator A Up
Bits 6:7 - Action for Comparator A Down
Bits 8:9 - Action for Comparator B Up
Bits 10:11 - Action for Comparator B Down
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Bits 0:1 - Action for Counter=0
Bits 2:3 - Action for Counter=LOAD
Bits 4:5 - Action for Comparator A Up
Bits 6:7 - Action for Comparator A Down
Bits 8:9 - Action for Comparator B Up
Bits 10:11 - Action for Comparator B Down
Bit 0 - Dead-Band Generator Enable
Bits 0:11 - Dead-Band Rise Delay
Bits 0:11 - Dead-Band Fall Delay
Bit 0 - Digital Comparator 0
Bit 1 - Digital Comparator 1
Bit 2 - Digital Comparator 2
Bit 3 - Digital Comparator 3
Bit 4 - Digital Comparator 4
Bit 5 - Digital Comparator 5
Bit 6 - Digital Comparator 6
Bit 7 - Digital Comparator 7
Bits 0:15 - Minimum Fault Period
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is LS
Checks if the value of the field is GS
Bit 3 - Load Register Update Mode
Bit 4 - Comparator A Update Mode
Bit 5 - Comparator B Update Mode
Bits 6:7 - PWMnGENA Update Mode
Bits 8:9 - PWMnGENB Update Mode
Bits 10:11 - PWMnDBCTL Update Mode
Bits 12:13 - PWMnDBRISE Update Mode
Bits 14:15 - PWMnDBFALL Update Mode
Bit 16 - Fault Condition Source
Bit 17 - Minimum Fault Period
Bit 18 - Latch Fault Input
Bit 0 - Interrupt for Counter=0
Bit 1 - Interrupt for Counter=PWMnLOAD
Bit 2 - Interrupt for Counter=PWMnCMPA Up
Bit 3 - Interrupt for Counter=PWMnCMPA Down
Bit 4 - Interrupt for Counter=PWMnCMPB Up
Bit 5 - Interrupt for Counter=PWMnCMPB Down
Bit 8 - Trigger for Counter=0
Bit 9 - Trigger for Counter=PWMnLOAD
Bit 10 - Trigger for Counter=PWMnCMPA Up
Bit 11 - Trigger for Counter=PWMnCMPA Down
Bit 12 - Trigger for Counter=PWMnCMPB Up
Bit 13 - Trigger for Counter=PWMnCMPB Down
Bit 0 - Counter=0 Interrupt Status
Bit 1 - Counter=Load Interrupt Status
Bit 2 - Comparator A Up Interrupt Status
Bit 3 - Comparator A Down Interrupt Status
Bit 4 - Comparator B Up Interrupt Status
Bit 5 - Comparator B Down Interrupt Status
Bit 0 - Counter=0 Interrupt
Bit 1 - Counter=Load Interrupt
Bit 2 - Comparator A Up Interrupt
Bit 3 - Comparator A Down Interrupt
Bit 4 - Comparator B Up Interrupt
Bit 5 - Comparator B Down Interrupt
Bits 0:15 - Counter Load Value
Bits 0:15 - Counter Value
Bits 0:15 - Comparator A Value
Bits 0:15 - Comparator B Value
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Bits 0:1 - Action for Counter=0
Bits 2:3 - Action for Counter=LOAD
Bits 4:5 - Action for Comparator A Up
Bits 6:7 - Action for Comparator A Down
Bits 8:9 - Action for Comparator B Up
Bits 10:11 - Action for Comparator B Down
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is INV
Checks if the value of the field is ZERO
Checks if the value of the field is ONE
Bits 0:1 - Action for Counter=0
Bits 2:3 - Action for Counter=LOAD
Bits 4:5 - Action for Comparator A Up
Bits 6:7 - Action for Comparator A Down
Bits 8:9 - Action for Comparator B Up
Bits 10:11 - Action for Comparator B Down
Bit 0 - Dead-Band Generator Enable
Bits 0:11 - Dead-Band Rise Delay
Bits 0:11 - Dead-Band Fall Delay
Bit 0 - Digital Comparator 0
Bit 1 - Digital Comparator 1
Bit 2 - Digital Comparator 2
Bit 3 - Digital Comparator 3
Bit 4 - Digital Comparator 4
Bit 5 - Digital Comparator 5
Bit 6 - Digital Comparator 6
Bit 7 - Digital Comparator 7
Bits 0:15 - Minimum Fault Period
Bit 0 - Digital Comparator 0 Trigger
Bit 1 - Digital Comparator 1 Trigger
Bit 2 - Digital Comparator 2 Trigger
Bit 3 - Digital Comparator 3 Trigger
Bit 4 - Digital Comparator 4 Trigger
Bit 5 - Digital Comparator 5 Trigger
Bit 6 - Digital Comparator 6 Trigger
Bit 7 - Digital Comparator 7 Trigger
Bit 0 - Digital Comparator 0 Trigger
Bit 1 - Digital Comparator 1 Trigger
Bit 2 - Digital Comparator 2 Trigger
Bit 3 - Digital Comparator 3 Trigger
Bit 4 - Digital Comparator 4 Trigger
Bit 5 - Digital Comparator 5 Trigger
Bit 6 - Digital Comparator 6 Trigger
Bit 7 - Digital Comparator 7 Trigger
Bit 0 - Digital Comparator 0 Trigger
Bit 1 - Digital Comparator 1 Trigger
Bit 2 - Digital Comparator 2 Trigger
Bit 3 - Digital Comparator 3 Trigger
Bit 4 - Digital Comparator 4 Trigger
Bit 5 - Digital Comparator 5 Trigger
Bit 6 - Digital Comparator 6 Trigger
Bit 7 - Digital Comparator 7 Trigger
Bit 0 - Digital Comparator 0 Trigger
Bit 1 - Digital Comparator 1 Trigger
Bit 2 - Digital Comparator 2 Trigger
Bit 3 - Digital Comparator 3 Trigger
Bit 4 - Digital Comparator 4 Trigger
Bit 5 - Digital Comparator 5 Trigger
Bit 6 - Digital Comparator 6 Trigger
Bit 7 - Digital Comparator 7 Trigger
Bits 4:7 - Fault Inputs (per PWM unit)
Bit 8 - Extended Synchronization
Get enumerated values variant
Checks if the value of the field is _1
Checks if the value of the field is _2
Checks if the value of the field is _4
Checks if the value of the field is _8
Checks if the value of the field is _16
Checks if the value of the field is _32
Checks if the value of the field is _64
Checks if the value of the field is _128
Bits 6:8 - Predivide Velocity
Bit 11 - Invert Index Pulse
Bit 13 - Enable Input Filter
Bits 16:19 - Input Filter Prescale Count
Bit 1 - Direction of Rotation
Bit 0 - Index Pulse Detected Interrupt Enable
Bit 1 - Timer Expires Interrupt Enable
Bit 2 - Direction Change Interrupt Enable
Bit 3 - Phase Error Interrupt Enable
Bit 0 - Index Pulse Asserted
Bit 1 - Velocity Timer Expired
Bit 2 - Direction Change Detected
Bit 3 - Phase Error Detected
Bit 0 - Index Pulse Interrupt
Bit 1 - Velocity Timer Expired Interrupt
Bit 2 - Direction Change Interrupt
Bit 3 - Phase Error Interrupt
Get enumerated values variant
Checks if the value of the field is _32_BIT_TIMER
Checks if the value of the field is _32_BIT_RTC
Checks if the value of the field is _16_BIT
Bits 0:2 - GPTM Configuration
Get enumerated values variant
Checks if the value of the field is _1_SHOT
Checks if the value of the field is PERIOD
Checks if the value of the field is CAP
Bits 0:1 - GPTM Timer A Mode
Bit 2 - GPTM Timer A Capture Mode
Bit 3 - GPTM Timer A Alternate Mode Select
Bit 4 - GPTM Timer A Count Direction
Bit 5 - GPTM Timer A Match Interrupt Enable
Bit 6 - GPTM Timer A Wait-on-Trigger
Bit 7 - GPTM Timer A Snap-Shot Mode
Bit 8 - GPTM Timer A Interval Load Write
Bit 9 - GPTM Timer A PWM Interrupt Enable
Bit 10 - GPTM Timer A Match Register Update
Bit 11 - GPTM Timer A PWM Legacy Operation
Get enumerated values variant
Checks if the value of the field is _1_SHOT
Checks if the value of the field is PERIOD
Checks if the value of the field is CAP
Bits 0:1 - GPTM Timer B Mode
Bit 2 - GPTM Timer B Capture Mode
Bit 3 - GPTM Timer B Alternate Mode Select
Bit 4 - GPTM Timer B Count Direction
Bit 5 - GPTM Timer B Match Interrupt Enable
Bit 6 - GPTM Timer B Wait-on-Trigger
Bit 7 - GPTM Timer B Snap-Shot Mode
Bit 8 - GPTM Timer B Interval Load Write
Bit 9 - GPTM Timer B PWM Interrupt Enable
Bit 10 - GPTM Timer B Match Register Update
Bit 11 - GPTM Timer B PWM Legacy Operation
Get enumerated values variant
Checks if the value of the field is POS
Checks if the value of the field is NEG
Checks if the value of the field is BOTH
Get enumerated values variant
Checks if the value of the field is POS
Checks if the value of the field is NEG
Checks if the value of the field is BOTH
Bit 0 - GPTM Timer A Enable
Bit 1 - GPTM Timer A Stall Enable
Bits 2:3 - GPTM Timer A Event Mode
Bit 4 - GPTM RTC Stall Enable
Bit 5 - GPTM Timer A Output Trigger Enable
Bit 6 - GPTM Timer A PWM Output Level
Bit 8 - GPTM Timer B Enable
Bit 9 - GPTM Timer B Stall Enable
Bits 10:11 - GPTM Timer B Event Mode
Bit 13 - GPTM Timer B Output Trigger Enable
Bit 14 - GPTM Timer B PWM Output Level
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Bits 0:1 - Synchronize GPTM Timer 0
Bits 2:3 - Synchronize GPTM Timer 1
Bits 4:5 - Synchronize GPTM Timer 2
Bits 6:7 - Synchronize GPTM Timer 3
Bits 8:9 - Synchronize GPTM Timer 4
Bits 10:11 - Synchronize GPTM Timer 5
Bits 12:13 - Synchronize GPTM 32/64-Bit Timer 0
Bits 14:15 - Synchronize GPTM 32/64-Bit Timer 1
Bits 16:17 - Synchronize GPTM 32/64-Bit Timer 2
Bits 18:19 - Synchronize GPTM 32/64-Bit Timer 3
Bits 20:21 - Synchronize GPTM 32/64-Bit Timer 4
Bits 22:23 - Synchronize GPTM 32/64-Bit Timer 5
Bit 0 - GPTM Timer A Time-Out Interrupt Mask
Bit 1 - GPTM Timer A Capture Mode Match Interrupt Mask
Bit 2 - GPTM Timer A Capture Mode Event Interrupt Mask
Bit 3 - GPTM RTC Interrupt Mask
Bit 4 - GPTM Timer A Match Interrupt Mask
Bit 8 - GPTM Timer B Time-Out Interrupt Mask
Bit 9 - GPTM Timer B Capture Mode Match Interrupt Mask
Bit 10 - GPTM Timer B Capture Mode Event Interrupt Mask
Bit 11 - GPTM Timer B Match Interrupt Mask
Bit 16 - 32/64-Bit Wide GPTM Write Update Error Interrupt Mask
Bit 0 - GPTM Timer A Time-Out Raw Interrupt
Bit 1 - GPTM Timer A Capture Mode Match Raw Interrupt
Bit 2 - GPTM Timer A Capture Mode Event Raw Interrupt
Bit 3 - GPTM RTC Raw Interrupt
Bit 4 - GPTM Timer A Match Raw Interrupt
Bit 8 - GPTM Timer B Time-Out Raw Interrupt
Bit 9 - GPTM Timer B Capture Mode Match Raw Interrupt
Bit 10 - GPTM Timer B Capture Mode Event Raw Interrupt
Bit 11 - GPTM Timer B Match Raw Interrupt
Bit 16 - 32/64-Bit Wide GPTM Write Update Error Raw Interrupt Status
Bit 0 - GPTM Timer A Time-Out Masked Interrupt
Bit 1 - GPTM Timer A Capture Mode Match Masked Interrupt
Bit 2 - GPTM Timer A Capture Mode Event Masked Interrupt
Bit 3 - GPTM RTC Masked Interrupt
Bit 4 - GPTM Timer A Match Masked Interrupt
Bit 8 - GPTM Timer B Time-Out Masked Interrupt
Bit 9 - GPTM Timer B Capture Mode Match Masked Interrupt
Bit 10 - GPTM Timer B Capture Mode Event Masked Interrupt
Bit 11 - GPTM Timer B Match Masked Interrupt
Bit 16 - 32/64-Bit Wide GPTM Write Update Error Masked Interrupt Status
Bits 0:31 - GPTM Timer A Match Register
Bits 0:31 - GPTM Timer B Match Register
Bits 0:7 - GPTM Timer A Prescale
Bits 8:15 - GPTM Timer A Prescale High Byte
Bits 0:7 - GPTM Timer B Prescale
Bits 8:15 - GPTM Timer B Prescale High Byte
Bits 0:7 - GPTM TimerA Prescale Match
Bits 8:15 - GPTM Timer A Prescale Match High Byte
Bits 0:7 - GPTM TimerB Prescale Match
Bits 8:15 - GPTM Timer B Prescale Match High Byte
Bits 0:15 - RTC Predivide Counter Value
Bits 0:15 - GPTM Timer A Prescaler Snapshot
Bits 0:15 - GPTM Timer A Prescaler Value
Bits 0:15 - GPTM Timer A Prescaler Value
Bits 0:15 - GPTM Timer B Prescaler Value
Get enumerated values variant
Checks if the value of the field is _16
Checks if the value of the field is _32
Get enumerated values variant
Checks if the value of the field is _32_BIT_TIMER
Checks if the value of the field is _32_BIT_RTC
Checks if the value of the field is _16_BIT
Bits 0:2 - GPTM Configuration
Get enumerated values variant
Checks if the value of the field is _1_SHOT
Checks if the value of the field is PERIOD
Checks if the value of the field is CAP
Bits 0:1 - GPTM Timer A Mode
Bit 2 - GPTM Timer A Capture Mode
Bit 3 - GPTM Timer A Alternate Mode Select
Bit 4 - GPTM Timer A Count Direction
Bit 5 - GPTM Timer A Match Interrupt Enable
Bit 6 - GPTM Timer A Wait-on-Trigger
Bit 7 - GPTM Timer A Snap-Shot Mode
Bit 8 - GPTM Timer A Interval Load Write
Bit 9 - GPTM Timer A PWM Interrupt Enable
Bit 10 - GPTM Timer A Match Register Update
Bit 11 - GPTM Timer A PWM Legacy Operation
Get enumerated values variant
Checks if the value of the field is _1_SHOT
Checks if the value of the field is PERIOD
Checks if the value of the field is CAP
Bits 0:1 - GPTM Timer B Mode
Bit 2 - GPTM Timer B Capture Mode
Bit 3 - GPTM Timer B Alternate Mode Select
Bit 4 - GPTM Timer B Count Direction
Bit 5 - GPTM Timer B Match Interrupt Enable
Bit 6 - GPTM Timer B Wait-on-Trigger
Bit 7 - GPTM Timer B Snap-Shot Mode
Bit 8 - GPTM Timer B Interval Load Write
Bit 9 - GPTM Timer B PWM Interrupt Enable
Bit 10 - GPTM Timer B Match Register Update
Bit 11 - GPTM Timer B PWM Legacy Operation
Get enumerated values variant
Checks if the value of the field is POS
Checks if the value of the field is NEG
Checks if the value of the field is BOTH
Get enumerated values variant
Checks if the value of the field is POS
Checks if the value of the field is NEG
Checks if the value of the field is BOTH
Bit 0 - GPTM Timer A Enable
Bit 1 - GPTM Timer A Stall Enable
Bits 2:3 - GPTM Timer A Event Mode
Bit 4 - GPTM RTC Stall Enable
Bit 5 - GPTM Timer A Output Trigger Enable
Bit 6 - GPTM Timer A PWM Output Level
Bit 8 - GPTM Timer B Enable
Bit 9 - GPTM Timer B Stall Enable
Bits 10:11 - GPTM Timer B Event Mode
Bit 13 - GPTM Timer B Output Trigger Enable
Bit 14 - GPTM Timer B PWM Output Level
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is TA
Checks if the value of the field is TB
Checks if the value of the field is TATB
Bits 0:1 - Synchronize GPTM Timer 0
Bits 2:3 - Synchronize GPTM Timer 1
Bits 4:5 - Synchronize GPTM Timer 2
Bits 6:7 - Synchronize GPTM Timer 3
Bits 8:9 - Synchronize GPTM Timer 4
Bits 10:11 - Synchronize GPTM Timer 5
Bits 12:13 - Synchronize GPTM 32/64-Bit Timer 0
Bits 14:15 - Synchronize GPTM 32/64-Bit Timer 1
Bits 16:17 - Synchronize GPTM 32/64-Bit Timer 2
Bits 18:19 - Synchronize GPTM 32/64-Bit Timer 3
Bits 20:21 - Synchronize GPTM 32/64-Bit Timer 4
Bits 22:23 - Synchronize GPTM 32/64-Bit Timer 5
Bit 0 - GPTM Timer A Time-Out Interrupt Mask
Bit 1 - GPTM Timer A Capture Mode Match Interrupt Mask
Bit 2 - GPTM Timer A Capture Mode Event Interrupt Mask
Bit 3 - GPTM RTC Interrupt Mask
Bit 4 - GPTM Timer A Match Interrupt Mask
Bit 8 - GPTM Timer B Time-Out Interrupt Mask
Bit 9 - GPTM Timer B Capture Mode Match Interrupt Mask
Bit 10 - GPTM Timer B Capture Mode Event Interrupt Mask
Bit 11 - GPTM Timer B Match Interrupt Mask
Bit 16 - 32/64-Bit Wide GPTM Write Update Error Interrupt Mask
Bit 0 - GPTM Timer A Time-Out Raw Interrupt
Bit 1 - GPTM Timer A Capture Mode Match Raw Interrupt
Bit 2 - GPTM Timer A Capture Mode Event Raw Interrupt
Bit 3 - GPTM RTC Raw Interrupt
Bit 4 - GPTM Timer A Match Raw Interrupt
Bit 8 - GPTM Timer B Time-Out Raw Interrupt
Bit 9 - GPTM Timer B Capture Mode Match Raw Interrupt
Bit 10 - GPTM Timer B Capture Mode Event Raw Interrupt
Bit 11 - GPTM Timer B Match Raw Interrupt
Bit 16 - 32/64-Bit Wide GPTM Write Update Error Raw Interrupt Status
Bit 0 - GPTM Timer A Time-Out Masked Interrupt
Bit 1 - GPTM Timer A Capture Mode Match Masked Interrupt
Bit 2 - GPTM Timer A Capture Mode Event Masked Interrupt
Bit 3 - GPTM RTC Masked Interrupt
Bit 4 - GPTM Timer A Match Masked Interrupt
Bit 8 - GPTM Timer B Time-Out Masked Interrupt
Bit 9 - GPTM Timer B Capture Mode Match Masked Interrupt
Bit 10 - GPTM Timer B Capture Mode Event Masked Interrupt
Bit 11 - GPTM Timer B Match Masked Interrupt
Bit 16 - 32/64-Bit Wide GPTM Write Update Error Masked Interrupt Status
Bits 0:31 - GPTM Timer A Match Register
Bits 0:31 - GPTM Timer B Match Register
Bits 0:7 - GPTM Timer A Prescale
Bits 8:15 - GPTM Timer A Prescale High Byte
Bits 0:7 - GPTM Timer B Prescale
Bits 8:15 - GPTM Timer B Prescale High Byte
Bits 0:7 - GPTM TimerA Prescale Match
Bits 8:15 - GPTM Timer A Prescale Match High Byte
Bits 0:7 - GPTM TimerB Prescale Match
Bits 8:15 - GPTM Timer B Prescale Match High Byte
Bits 0:15 - RTC Predivide Counter Value
Bits 0:15 - GPTM Timer A Prescaler Snapshot
Bits 0:15 - GPTM Timer A Prescaler Value
Bits 0:15 - GPTM Timer A Prescaler Value
Bits 0:15 - GPTM Timer B Prescaler Value
Get enumerated values variant
Checks if the value of the field is _16
Checks if the value of the field is _32
Bit 0 - SS0 Raw Interrupt Status
Bit 1 - SS1 Raw Interrupt Status
Bit 2 - SS2 Raw Interrupt Status
Bit 3 - SS3 Raw Interrupt Status
Bit 16 - Digital Comparator Raw Interrupt Status
Bit 0 - SS0 Interrupt Mask
Bit 1 - SS1 Interrupt Mask
Bit 2 - SS2 Interrupt Mask
Bit 3 - SS3 Interrupt Mask
Bit 16 - Digital Comparator Interrupt on SS0
Bit 17 - Digital Comparator Interrupt on SS1
Bit 18 - Digital Comparator Interrupt on SS2
Bit 19 - Digital Comparator Interrupt on SS3
Bit 0 - SS0 Interrupt Status and Clear
Bit 1 - SS1 Interrupt Status and Clear
Bit 2 - SS2 Interrupt Status and Clear
Bit 3 - SS3 Interrupt Status and Clear
Bit 16 - Digital Comparator Interrupt Status on SS0
Bit 17 - Digital Comparator Interrupt Status on SS1
Bit 18 - Digital Comparator Interrupt Status on SS2
Bit 19 - Digital Comparator Interrupt Status on SS3
Bit 0 - SS0 FIFO Overflow
Bit 1 - SS1 FIFO Overflow
Bit 2 - SS2 FIFO Overflow
Bit 3 - SS3 FIFO Overflow
Get enumerated values variant
Checks if the value of the field is PROCESSOR
Checks if the value of the field is COMP0
Checks if the value of the field is COMP1
Checks if the value of the field is EXTERNAL
Checks if the value of the field is TIMER
Checks if the value of the field is PWM0
Checks if the value of the field is PWM1
Checks if the value of the field is PWM2
Checks if the value of the field is PWM3
Checks if the value of the field is ALWAYS
Get enumerated values variant
Checks if the value of the field is PROCESSOR
Checks if the value of the field is COMP0
Checks if the value of the field is COMP1
Checks if the value of the field is EXTERNAL
Checks if the value of the field is TIMER
Checks if the value of the field is PWM0
Checks if the value of the field is PWM1
Checks if the value of the field is PWM2
Checks if the value of the field is PWM3
Checks if the value of the field is ALWAYS
Get enumerated values variant
Checks if the value of the field is PROCESSOR
Checks if the value of the field is COMP0
Checks if the value of the field is COMP1
Checks if the value of the field is EXTERNAL
Checks if the value of the field is TIMER
Checks if the value of the field is PWM0
Checks if the value of the field is PWM1
Checks if the value of the field is PWM2
Checks if the value of the field is PWM3
Checks if the value of the field is ALWAYS
Get enumerated values variant
Checks if the value of the field is PROCESSOR
Checks if the value of the field is COMP0
Checks if the value of the field is COMP1
Checks if the value of the field is EXTERNAL
Checks if the value of the field is TIMER
Checks if the value of the field is PWM0
Checks if the value of the field is PWM1
Checks if the value of the field is PWM2
Checks if the value of the field is PWM3
Checks if the value of the field is ALWAYS
Bits 0:3 - SS0 Trigger Select
Bits 4:7 - SS1 Trigger Select
Bits 8:11 - SS2 Trigger Select
Bits 12:15 - SS3 Trigger Select
Bit 0 - SS0 FIFO Underflow
Bit 1 - SS1 FIFO Underflow
Bit 2 - SS2 FIFO Underflow
Bit 3 - SS3 FIFO Underflow
Get enumerated values variant
Checks if the value of the field is _0
Checks if the value of the field is _1
Get enumerated values variant
Checks if the value of the field is _0
Checks if the value of the field is _1
Get enumerated values variant
Checks if the value of the field is _0
Checks if the value of the field is _1
Get enumerated values variant
Checks if the value of the field is _0
Checks if the value of the field is _1
Bits 4:5 - Generator 0 PWM Module Trigger Select
Bits 12:13 - Generator 1 PWM Module Trigger Select
Bits 20:21 - Generator 2 PWM Module Trigger Select
Bits 28:29 - Generator 3 PWM Module Trigger Select
Bits 12:13 - SS3 Priority
Get enumerated values variant
Checks if the value of the field is _0
Checks if the value of the field is _22_5
Checks if the value of the field is _45
Checks if the value of the field is _67_5
Checks if the value of the field is _90
Checks if the value of the field is _112_5
Checks if the value of the field is _135
Checks if the value of the field is _157_5
Checks if the value of the field is _180
Checks if the value of the field is _202_5
Checks if the value of the field is _225
Checks if the value of the field is _247_5
Checks if the value of the field is _270
Checks if the value of the field is _292_5
Checks if the value of the field is _315
Checks if the value of the field is _337_5
Bits 0:3 - Phase Difference
Bit 27 - Synchronize Wait
Bit 31 - Global Synchronize
Get enumerated values variant
Checks if the value of the field is OFF
Checks if the value of the field is _2X
Checks if the value of the field is _4X
Checks if the value of the field is _8X
Checks if the value of the field is _16X
Checks if the value of the field is _32X
Checks if the value of the field is _64X
Bits 0:2 - Hardware Averaging Control
Bit 0 - Digital Comparator 0 Interrupt Status and Clear
Bit 1 - Digital Comparator 1 Interrupt Status and Clear
Bit 2 - Digital Comparator 2 Interrupt Status and Clear
Bit 3 - Digital Comparator 3 Interrupt Status and Clear
Bit 4 - Digital Comparator 4 Interrupt Status and Clear
Bit 5 - Digital Comparator 5 Interrupt Status and Clear
Bit 6 - Digital Comparator 6 Interrupt Status and Clear
Bit 7 - Digital Comparator 7 Interrupt Status and Clear
Get enumerated values variant
Checks if the value of the field is INTERNAL
Bit 0 - Voltage Reference Select
Bits 0:3 - 1st Sample Input Select
Bits 4:7 - 2nd Sample Input Select
Bits 8:11 - 3rd Sample Input Select
Bits 12:15 - 4th Sample Input Select
Bits 16:19 - 5th Sample Input Select
Bits 20:23 - 6th Sample Input Select
Bits 24:27 - 7th Sample Input Select
Bits 28:31 - 8th Sample Input Select
Bit 0 - 1st Sample Differential Input Select
Bit 1 - 1st Sample is End of Sequence
Bit 2 - 1st Sample Interrupt Enable
Bit 3 - 1st Sample Temp Sensor Select
Bit 4 - 2nd Sample Differential Input Select
Bit 5 - 2nd Sample is End of Sequence
Bit 6 - 2nd Sample Interrupt Enable
Bit 7 - 2nd Sample Temp Sensor Select
Bit 8 - 3rd Sample Differential Input Select
Bit 9 - 3rd Sample is End of Sequence
Bit 10 - 3rd Sample Interrupt Enable
Bit 11 - 3rd Sample Temp Sensor Select
Bit 12 - 4th Sample Differential Input Select
Bit 13 - 4th Sample is End of Sequence
Bit 14 - 4th Sample Interrupt Enable
Bit 15 - 4th Sample Temp Sensor Select
Bit 16 - 5th Sample Differential Input Select
Bit 17 - 5th Sample is End of Sequence
Bit 18 - 5th Sample Interrupt Enable
Bit 19 - 5th Sample Temp Sensor Select
Bit 20 - 6th Sample Differential Input Select
Bit 21 - 6th Sample is End of Sequence
Bit 22 - 6th Sample Interrupt Enable
Bit 23 - 6th Sample Temp Sensor Select
Bit 24 - 7th Sample Differential Input Select
Bit 25 - 7th Sample is End of Sequence
Bit 26 - 7th Sample Interrupt Enable
Bit 27 - 7th Sample Temp Sensor Select
Bit 28 - 8th Sample Differential Input Select
Bit 29 - 8th Sample is End of Sequence
Bit 30 - 8th Sample Interrupt Enable
Bit 31 - 8th Sample Temp Sensor Select
Bits 0:11 - Conversion Result Data
Bits 0:3 - FIFO Tail Pointer
Bits 4:7 - FIFO Head Pointer
Bit 0 - Sample 0 Digital Comparator Operation
Bit 4 - Sample 1 Digital Comparator Operation
Bit 8 - Sample 2 Digital Comparator Operation
Bit 12 - Sample 3 Digital Comparator Operation
Bit 16 - Sample 4 Digital Comparator Operation
Bit 20 - Sample 5 Digital Comparator Operation
Bit 24 - Sample 6 Digital Comparator Operation
Bit 28 - Sample 7 Digital Comparator Operation
Bits 0:3 - Sample 0 Digital Comparator Select
Bits 4:7 - Sample 1 Digital Comparator Select
Bits 8:11 - Sample 2 Digital Comparator Select
Bits 12:15 - Sample 3 Digital Comparator Select
Bits 16:19 - Sample 4 Digital Comparator Select
Bits 20:23 - Sample 5 Digital Comparator Select
Bits 24:27 - Sample 6 Digital Comparator Select
Bits 28:31 - Sample 7 Digital Comparator Select
Bits 0:3 - 1st Sample Input Select
Bits 4:7 - 2nd Sample Input Select
Bits 8:11 - 3rd Sample Input Select
Bits 12:15 - 4th Sample Input Select
Bit 0 - 1st Sample Differential Input Select
Bit 1 - 1st Sample is End of Sequence
Bit 2 - 1st Sample Interrupt Enable
Bit 3 - 1st Sample Temp Sensor Select
Bit 4 - 2nd Sample Differential Input Select
Bit 5 - 2nd Sample is End of Sequence
Bit 6 - 2nd Sample Interrupt Enable
Bit 7 - 2nd Sample Temp Sensor Select
Bit 8 - 3rd Sample Differential Input Select
Bit 9 - 3rd Sample is End of Sequence
Bit 10 - 3rd Sample Interrupt Enable
Bit 11 - 3rd Sample Temp Sensor Select
Bit 12 - 4th Sample Differential Input Select
Bit 13 - 4th Sample is End of Sequence
Bit 14 - 4th Sample Interrupt Enable
Bit 15 - 4th Sample Temp Sensor Select
Bits 0:11 - Conversion Result Data
Bits 0:3 - FIFO Tail Pointer
Bits 4:7 - FIFO Head Pointer
Bit 0 - Sample 0 Digital Comparator Operation
Bit 4 - Sample 1 Digital Comparator Operation
Bit 8 - Sample 2 Digital Comparator Operation
Bit 12 - Sample 3 Digital Comparator Operation
Bits 0:3 - Sample 0 Digital Comparator Select
Bits 4:7 - Sample 1 Digital Comparator Select
Bits 8:11 - Sample 2 Digital Comparator Select
Bits 12:15 - Sample 3 Digital Comparator Select
Bits 0:3 - 1st Sample Input Select
Bits 4:7 - 2nd Sample Input Select
Bits 8:11 - 3rd Sample Input Select
Bits 12:15 - 4th Sample Input Select
Bit 0 - 1st Sample Differential Input Select
Bit 1 - 1st Sample is End of Sequence
Bit 2 - 1st Sample Interrupt Enable
Bit 3 - 1st Sample Temp Sensor Select
Bit 4 - 2nd Sample Differential Input Select
Bit 5 - 2nd Sample is End of Sequence
Bit 6 - 2nd Sample Interrupt Enable
Bit 7 - 2nd Sample Temp Sensor Select
Bit 8 - 3rd Sample Differential Input Select
Bit 9 - 3rd Sample is End of Sequence
Bit 10 - 3rd Sample Interrupt Enable
Bit 11 - 3rd Sample Temp Sensor Select
Bit 12 - 4th Sample Differential Input Select
Bit 13 - 4th Sample is End of Sequence
Bit 14 - 4th Sample Interrupt Enable
Bit 15 - 4th Sample Temp Sensor Select
Bits 0:11 - Conversion Result Data
Bits 0:3 - FIFO Tail Pointer
Bits 4:7 - FIFO Head Pointer
Bit 0 - Sample 0 Digital Comparator Operation
Bit 4 - Sample 1 Digital Comparator Operation
Bit 8 - Sample 2 Digital Comparator Operation
Bit 12 - Sample 3 Digital Comparator Operation
Bits 0:3 - Sample 0 Digital Comparator Select
Bits 4:7 - Sample 1 Digital Comparator Select
Bits 8:11 - Sample 2 Digital Comparator Select
Bits 12:15 - Sample 3 Digital Comparator Select
Bits 0:3 - 1st Sample Input Select
Bit 0 - Sample Differential Input Select
Bit 2 - Sample Interrupt Enable
Bit 3 - 1st Sample Temp Sensor Select
Bits 0:11 - Conversion Result Data
Bits 0:3 - FIFO Tail Pointer
Bits 4:7 - FIFO Head Pointer
Bit 0 - Sample 0 Digital Comparator Operation
Bits 0:3 - Sample 0 Digital Comparator Select
Get enumerated values variant
Checks if the value of the field is ALWAYS
Checks if the value of the field is ONCE
Checks if the value of the field is HALWAYS
Checks if the value of the field is HONCE
Get enumerated values variant
Checks if the value of the field is LOW
Checks if the value of the field is MID
Checks if the value of the field is HIGH
Get enumerated values variant
Checks if the value of the field is ALWAYS
Checks if the value of the field is ONCE
Checks if the value of the field is HALWAYS
Checks if the value of the field is HONCE
Get enumerated values variant
Checks if the value of the field is LOW
Checks if the value of the field is MID
Checks if the value of the field is HIGH
Bits 0:1 - Comparison Interrupt Mode
Bits 2:3 - Comparison Interrupt Condition
Bit 4 - Comparison Interrupt Enable
Bits 8:9 - Comparison Trigger Mode
Bits 10:11 - Comparison Trigger Condition
Bit 12 - Comparison Trigger Enable
Get enumerated values variant
Checks if the value of the field is ALWAYS
Checks if the value of the field is ONCE
Checks if the value of the field is HALWAYS
Checks if the value of the field is HONCE
Get enumerated values variant
Checks if the value of the field is LOW
Checks if the value of the field is MID
Checks if the value of the field is HIGH
Get enumerated values variant
Checks if the value of the field is ALWAYS
Checks if the value of the field is ONCE
Checks if the value of the field is HALWAYS
Checks if the value of the field is HONCE
Get enumerated values variant
Checks if the value of the field is LOW
Checks if the value of the field is MID
Checks if the value of the field is HIGH
Bits 0:1 - Comparison Interrupt Mode
Bits 2:3 - Comparison Interrupt Condition
Bit 4 - Comparison Interrupt Enable
Bits 8:9 - Comparison Trigger Mode
Bits 10:11 - Comparison Trigger Condition
Bit 12 - Comparison Trigger Enable
Get enumerated values variant
Checks if the value of the field is ALWAYS
Checks if the value of the field is ONCE
Checks if the value of the field is HALWAYS
Checks if the value of the field is HONCE
Get enumerated values variant
Checks if the value of the field is LOW
Checks if the value of the field is MID
Checks if the value of the field is HIGH
Get enumerated values variant
Checks if the value of the field is ALWAYS
Checks if the value of the field is ONCE
Checks if the value of the field is HALWAYS
Checks if the value of the field is HONCE
Get enumerated values variant
Checks if the value of the field is LOW
Checks if the value of the field is MID
Checks if the value of the field is HIGH
Bits 0:1 - Comparison Interrupt Mode
Bits 2:3 - Comparison Interrupt Condition
Bit 4 - Comparison Interrupt Enable
Bits 8:9 - Comparison Trigger Mode
Bits 10:11 - Comparison Trigger Condition
Bit 12 - Comparison Trigger Enable
Get enumerated values variant
Checks if the value of the field is ALWAYS
Checks if the value of the field is ONCE
Checks if the value of the field is HALWAYS
Checks if the value of the field is HONCE
Get enumerated values variant
Checks if the value of the field is LOW
Checks if the value of the field is MID
Checks if the value of the field is HIGH
Get enumerated values variant
Checks if the value of the field is ALWAYS
Checks if the value of the field is ONCE
Checks if the value of the field is HALWAYS
Checks if the value of the field is HONCE
Get enumerated values variant
Checks if the value of the field is LOW
Checks if the value of the field is MID
Checks if the value of the field is HIGH
Bits 0:1 - Comparison Interrupt Mode
Bits 2:3 - Comparison Interrupt Condition
Bit 4 - Comparison Interrupt Enable
Bits 8:9 - Comparison Trigger Mode
Bits 10:11 - Comparison Trigger Condition
Bit 12 - Comparison Trigger Enable
Get enumerated values variant
Checks if the value of the field is ALWAYS
Checks if the value of the field is ONCE
Checks if the value of the field is HALWAYS
Checks if the value of the field is HONCE
Get enumerated values variant
Checks if the value of the field is LOW
Checks if the value of the field is MID
Checks if the value of the field is HIGH
Get enumerated values variant
Checks if the value of the field is ALWAYS
Checks if the value of the field is ONCE
Checks if the value of the field is HALWAYS
Checks if the value of the field is HONCE
Get enumerated values variant
Checks if the value of the field is LOW
Checks if the value of the field is MID
Checks if the value of the field is HIGH
Bits 0:1 - Comparison Interrupt Mode
Bits 2:3 - Comparison Interrupt Condition
Bit 4 - Comparison Interrupt Enable
Bits 8:9 - Comparison Trigger Mode
Bits 10:11 - Comparison Trigger Condition
Bit 12 - Comparison Trigger Enable
Get enumerated values variant
Checks if the value of the field is ALWAYS
Checks if the value of the field is ONCE
Checks if the value of the field is HALWAYS
Checks if the value of the field is HONCE
Get enumerated values variant
Checks if the value of the field is LOW
Checks if the value of the field is MID
Checks if the value of the field is HIGH
Get enumerated values variant
Checks if the value of the field is ALWAYS
Checks if the value of the field is ONCE
Checks if the value of the field is HALWAYS
Checks if the value of the field is HONCE
Get enumerated values variant
Checks if the value of the field is LOW
Checks if the value of the field is MID
Checks if the value of the field is HIGH
Bits 0:1 - Comparison Interrupt Mode
Bits 2:3 - Comparison Interrupt Condition
Bit 4 - Comparison Interrupt Enable
Bits 8:9 - Comparison Trigger Mode
Bits 10:11 - Comparison Trigger Condition
Bit 12 - Comparison Trigger Enable
Get enumerated values variant
Checks if the value of the field is ALWAYS
Checks if the value of the field is ONCE
Checks if the value of the field is HALWAYS
Checks if the value of the field is HONCE
Get enumerated values variant
Checks if the value of the field is LOW
Checks if the value of the field is MID
Checks if the value of the field is HIGH
Get enumerated values variant
Checks if the value of the field is ALWAYS
Checks if the value of the field is ONCE
Checks if the value of the field is HALWAYS
Checks if the value of the field is HONCE
Get enumerated values variant
Checks if the value of the field is LOW
Checks if the value of the field is MID
Checks if the value of the field is HIGH
Bits 0:1 - Comparison Interrupt Mode
Bits 2:3 - Comparison Interrupt Condition
Bit 4 - Comparison Interrupt Enable
Bits 8:9 - Comparison Trigger Mode
Bits 10:11 - Comparison Trigger Condition
Bit 12 - Comparison Trigger Enable
Get enumerated values variant
Checks if the value of the field is ALWAYS
Checks if the value of the field is ONCE
Checks if the value of the field is HALWAYS
Checks if the value of the field is HONCE
Get enumerated values variant
Checks if the value of the field is LOW
Checks if the value of the field is MID
Checks if the value of the field is HIGH
Get enumerated values variant
Checks if the value of the field is ALWAYS
Checks if the value of the field is ONCE
Checks if the value of the field is HALWAYS
Checks if the value of the field is HONCE
Get enumerated values variant
Checks if the value of the field is LOW
Checks if the value of the field is MID
Checks if the value of the field is HIGH
Bits 0:1 - Comparison Interrupt Mode
Bits 2:3 - Comparison Interrupt Condition
Bit 4 - Comparison Interrupt Enable
Bits 8:9 - Comparison Trigger Mode
Bits 10:11 - Comparison Trigger Condition
Bit 12 - Comparison Trigger Enable
Get enumerated values variant
Checks if the value of the field is _125K
Checks if the value of the field is _250K
Checks if the value of the field is _500K
Checks if the value of the field is _1M
Get enumerated values variant
Checks if the value of the field is SAR
Bits 0:3 - Maximum ADC Sample Rate
Bits 4:9 - ADC Channel Count
Bits 10:15 - Digital Comparator Count
Bits 16:17 - ADC Architecture
Bit 23 - Temperature Sensor
Get enumerated values variant
Checks if the value of the field is _125K
Checks if the value of the field is _250K
Checks if the value of the field is _500K
Checks if the value of the field is _1M
Bits 0:3 - ADC Sample Rate
Get enumerated values variant
Checks if the value of the field is SYSPLL
Checks if the value of the field is PIOSC
Bits 0:3 - ADC Clock Source
Bit 0 - Comparator 0 Masked Interrupt Status
Bit 1 - Comparator 1 Masked Interrupt Status
Bit 0 - Comparator 0 Interrupt Status
Bit 1 - Comparator 1 Interrupt Status
Bit 0 - Comparator 0 Interrupt Enable
Bit 1 - Comparator 1 Interrupt Enable
Bits 0:3 - Resistor Ladder Voltage Ref
Bit 8 - Resistor Ladder Range
Bit 9 - Resistor Ladder Enable
Bit 1 - Comparator Output Value
Get enumerated values variant
Checks if the value of the field is LEVEL
Checks if the value of the field is FALL
Checks if the value of the field is RISE
Checks if the value of the field is BOTH
Get enumerated values variant
Checks if the value of the field is LEVEL
Checks if the value of the field is FALL
Checks if the value of the field is RISE
Checks if the value of the field is BOTH
Get enumerated values variant
Checks if the value of the field is PIN
Checks if the value of the field is PIN0
Checks if the value of the field is REF
Bit 1 - Comparator Output Invert
Bits 2:3 - Interrupt Sense
Bit 4 - Interrupt Sense Level Value
Bit 7 - Trigger Sense Level Value
Bits 9:10 - Analog Source Positive
Bit 11 - Trigger Output Enable
Bit 1 - Comparator Output Value
Get enumerated values variant
Checks if the value of the field is LEVEL
Checks if the value of the field is FALL
Checks if the value of the field is RISE
Checks if the value of the field is BOTH
Get enumerated values variant
Checks if the value of the field is LEVEL
Checks if the value of the field is FALL
Checks if the value of the field is RISE
Checks if the value of the field is BOTH
Get enumerated values variant
Checks if the value of the field is PIN
Checks if the value of the field is PIN0
Checks if the value of the field is REF
Bit 1 - Comparator Output Invert
Bits 2:3 - Interrupt Sense
Bit 4 - Interrupt Sense Level Value
Bit 7 - Trigger Sense Level Value
Bits 9:10 - Analog Source Positive
Bit 11 - Trigger Output Enable
Bit 0 - Comparator 0 Present
Bit 1 - Comparator 1 Present
Bit 16 - Comparator Output 0 Present
Bit 17 - Comparator Output 1 Present
Bit 1 - CAN Interrupt Enable
Bit 2 - Status Interrupt Enable
Bit 3 - Error Interrupt Enable
Bit 5 - Disable Automatic-Retransmission
Bit 6 - Configuration Change Enable
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is STUFF
Checks if the value of the field is FORM
Checks if the value of the field is ACK
Checks if the value of the field is BIT1
Checks if the value of the field is BIT0
Checks if the value of the field is CRC
Checks if the value of the field is NOEVENT
Bits 0:2 - Last Error Code
Bit 3 - Transmitted a Message Successfully
Bit 4 - Received a Message Successfully
Bits 0:7 - Transmit Error Counter
Bits 8:14 - Receive Error Counter
Bit 15 - Received Error Passive
Bits 0:5 - Baud Rate Prescaler
Bits 6:7 - (Re)Synchronization Jump Width
Bits 8:11 - Time Segment Before Sample Point
Bits 12:14 - Time Segment after Sample Point
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is STATUS
Bits 0:15 - Interrupt Identifier
Get enumerated values variant
Checks if the value of the field is CANCTL
Checks if the value of the field is SAMPLE
Checks if the value of the field is DOMINANT
Checks if the value of the field is RECESSIVE
Bits 5:6 - Transmit Control
Bit 7 - Receive Observation
Bits 0:3 - Baud Rate Prescaler Extension
Bits 0:5 - Message Number
Bit 0 - Access Data Byte 4 to 7
Bit 1 - Access Data Byte 0 to 3
Bit 2 - Access Transmission Request
Bit 3 - Clear Interrupt Pending Bit
Bit 4 - Access Control Bits
Bit 5 - Access Arbitration Bits
Bits 0:15 - Identifier Mask
Bits 0:12 - Identifier Mask
Bit 14 - Mask Message Direction
Bit 15 - Mask Extended Identifier
Bits 0:15 - Message Identifier
Bits 0:12 - Message Identifier
Bit 13 - Message Direction
Bit 14 - Extended Identifier
Bits 0:3 - Data Length Code
Bit 10 - Receive Interrupt Enable
Bit 11 - Transmit Interrupt Enable
Bit 12 - Use Acceptance Mask
Bit 13 - Interrupt Pending
Bits 0:5 - Message Number
Bit 0 - Access Data Byte 4 to 7
Bit 1 - Access Data Byte 0 to 3
Bit 2 - Access Transmission Request
Bit 3 - Clear Interrupt Pending Bit
Bit 4 - Access Control Bits
Bit 5 - Access Arbitration Bits
Bits 0:15 - Identifier Mask
Bits 0:12 - Identifier Mask
Bit 14 - Mask Message Direction
Bit 15 - Mask Extended Identifier
Bits 0:15 - Message Identifier
Bits 0:12 - Message Identifier
Bit 13 - Message Direction
Bit 14 - Extended Identifier
Bits 0:3 - Data Length Code
Bit 10 - Receive Interrupt Enable
Bit 11 - Transmit Interrupt Enable
Bit 12 - Use Acceptance Mask
Bit 13 - Interrupt Pending
Bits 0:15 - Transmission Request Bits
Bits 0:15 - Transmission Request Bits
Bits 0:15 - New Data Bits
Bits 0:15 - New Data Bits
Bits 0:15 - Interrupt Pending Bits
Bits 0:15 - Interrupt Pending Bits
Bits 0:15 - Message Valid Bits
Bits 0:15 - Message Valid Bits
Bits 0:6 - Function Address
Bit 6 - Soft Connect/Disconnect
Bit 7 - Isochronous Update
Bit 0 - TX and RX Endpoint 0 Interrupt
Bit 1 - TX Endpoint 1 Interrupt
Bit 2 - TX Endpoint 2 Interrupt
Bit 3 - TX Endpoint 3 Interrupt
Bit 4 - TX Endpoint 4 Interrupt
Bit 5 - TX Endpoint 5 Interrupt
Bit 6 - TX Endpoint 6 Interrupt
Bit 7 - TX Endpoint 7 Interrupt
Bit 1 - RX Endpoint 1 Interrupt
Bit 2 - RX Endpoint 2 Interrupt
Bit 3 - RX Endpoint 3 Interrupt
Bit 4 - RX Endpoint 4 Interrupt
Bit 5 - RX Endpoint 5 Interrupt
Bit 6 - RX Endpoint 6 Interrupt
Bit 7 - RX Endpoint 7 Interrupt
Bit 0 - TX and RX Endpoint 0 Interrupt Enable
Bit 1 - TX Endpoint 1 Interrupt Enable
Bit 2 - TX Endpoint 2 Interrupt Enable
Bit 3 - TX Endpoint 3 Interrupt Enable
Bit 4 - TX Endpoint 4 Interrupt Enable
Bit 5 - TX Endpoint 5 Interrupt Enable
Bit 6 - TX Endpoint 6 Interrupt Enable
Bit 7 - TX Endpoint 7 Interrupt Enable
Bit 1 - RX Endpoint 1 Interrupt Enable
Bit 2 - RX Endpoint 2 Interrupt Enable
Bit 3 - RX Endpoint 3 Interrupt Enable
Bit 4 - RX Endpoint 4 Interrupt Enable
Bit 5 - RX Endpoint 5 Interrupt Enable
Bit 6 - RX Endpoint 6 Interrupt Enable
Bit 7 - RX Endpoint 7 Interrupt Enable
Bit 0 - SUSPEND Signaling Detected
Bit 1 - RESUME Signaling Detected
Bit 2 - RESET Signaling Detected
Bit 5 - Session Disconnect (OTG only)
Bit 6 - SESSION REQUEST (OTG only)
Bit 7 - VBUS Error (OTG only)
Bit 0 - Enable SUSPEND Interrupt
Bit 1 - Enable RESUME Interrupt
Bit 2 - Enable Babble Interrupt
Bit 2 - Enable RESET Interrupt
Bit 3 - Enable Start-of-Frame Interrupt
Bit 4 - Enable Connect Interrupt
Bit 5 - Enable Disconnect Interrupt
Bit 6 - Enable Session Request (OTG only)
Bit 7 - Enable VBUS Error Interrupt (OTG only)
Bits 0:3 - Endpoint Index
Bit 5 - Force Full-Speed Mode
Bits 0:31 - Endpoint Data
Bits 0:31 - Endpoint Data
Bits 0:31 - Endpoint Data
Bits 0:31 - Endpoint Data
Bits 0:31 - Endpoint Data
Bits 0:31 - Endpoint Data
Bits 0:31 - Endpoint Data
Bits 0:31 - Endpoint Data
Get enumerated values variant
Checks if the value of the field is NONE
Checks if the value of the field is SEND
Checks if the value of the field is AVALID
Checks if the value of the field is VALID
Bit 0 - Session Start/End (OTG only)
Bit 1 - Host Request (OTG only)
Bits 3:4 - VBUS Level (OTG only)
Bit 5 - Low-Speed Device Detected
Bit 6 - Full-Speed Device Detected
Bit 7 - Device Mode (OTG only)
Get enumerated values variant
Checks if the value of the field is _8
Checks if the value of the field is _16
Checks if the value of the field is _32
Checks if the value of the field is _64
Checks if the value of the field is _128
Checks if the value of the field is _256
Checks if the value of the field is _512
Checks if the value of the field is _1024
Checks if the value of the field is _2048
Bits 0:3 - Max Packet Size
Bit 4 - Double Packet Buffer Support
Get enumerated values variant
Checks if the value of the field is _8
Checks if the value of the field is _16
Checks if the value of the field is _32
Checks if the value of the field is _64
Checks if the value of the field is _128
Checks if the value of the field is _256
Checks if the value of the field is _512
Checks if the value of the field is _1024
Checks if the value of the field is _2048
Bits 0:3 - Max Packet Size
Bit 4 - Double Packet Buffer Support
Bits 0:8 - Transmit/Receive Start Address
Bits 0:8 - Transmit/Receive Start Address
Bits 0:7 - VBUS Pulse Length
Bits 0:7 - Full-Speed End-of-Frame Gap
Bits 0:7 - Low-Speed End-of-Frame Gap
Bits 0:6 - Device Address
Bits 0:6 - Device Address
Bits 0:6 - Device Address
Bits 0:6 - Device Address
Bits 0:6 - Device Address
Bits 0:6 - Device Address
Bits 0:6 - Device Address
Bits 0:6 - Device Address
Bits 0:6 - Device Address
Bits 0:6 - Device Address
Bits 0:6 - Device Address
Bits 0:6 - Device Address
Bits 0:6 - Device Address
Bits 0:6 - Device Address
Bits 0:6 - Device Address
Get enumerated values variant
Checks if the value of the field is FULL
Checks if the value of the field is LOW
Bits 6:7 - Operating Speed
Bits 0:10 - Maximum Payload
Bit 0 - Transmit Packet Ready
Bit 6 - Clear Data Toggle
Bit 1 - Data Toggle Write Enable
Bit 3 - Force Data Toggle
Bit 4 - DMA Request Enable
Bit 6 - Isochronous Transfers
Bits 0:10 - Maximum Payload
Bit 0 - Receive Packet Ready
Bit 7 - Clear Data Toggle
Bit 2 - Data Toggle Write Enable
Bit 5 - DMA Request Enable
Bit 6 - Isochronous Transfers
Bits 0:12 - Receive Packet Count
Get enumerated values variant
Checks if the value of the field is CTRL
Checks if the value of the field is ISOC
Checks if the value of the field is BULK
Checks if the value of the field is INT
Get enumerated values variant
Checks if the value of the field is DFLT
Checks if the value of the field is FULL
Checks if the value of the field is LOW
Bits 0:3 - Target Endpoint Number
Bits 6:7 - Operating Speed
Get enumerated values variant
Checks if the value of the field is CTRL
Checks if the value of the field is ISOC
Checks if the value of the field is BULK
Checks if the value of the field is INT
Get enumerated values variant
Checks if the value of the field is DFLT
Checks if the value of the field is FULL
Checks if the value of the field is LOW
Bits 0:3 - Target Endpoint Number
Bits 6:7 - Operating Speed
Bits 0:10 - Maximum Payload
Bit 0 - Transmit Packet Ready
Bit 6 - Clear Data Toggle
Bit 1 - Data Toggle Write Enable
Bit 3 - Force Data Toggle
Bit 4 - DMA Request Enable
Bit 6 - Isochronous Transfers
Bits 0:10 - Maximum Payload
Bit 0 - Receive Packet Ready
Bit 7 - Clear Data Toggle
Bit 2 - Data Toggle Write Enable
Bit 5 - DMA Request Enable
Bit 6 - Isochronous Transfers
Bits 0:12 - Receive Packet Count
Get enumerated values variant
Checks if the value of the field is CTRL
Checks if the value of the field is ISOC
Checks if the value of the field is BULK
Checks if the value of the field is INT
Get enumerated values variant
Checks if the value of the field is DFLT
Checks if the value of the field is FULL
Checks if the value of the field is LOW
Bits 0:3 - Target Endpoint Number
Bits 6:7 - Operating Speed
Get enumerated values variant
Checks if the value of the field is CTRL
Checks if the value of the field is ISOC
Checks if the value of the field is BULK
Checks if the value of the field is INT
Get enumerated values variant
Checks if the value of the field is DFLT
Checks if the value of the field is FULL
Checks if the value of the field is LOW
Bits 0:3 - Target Endpoint Number
Bits 6:7 - Operating Speed
Bits 0:10 - Maximum Payload
Bit 0 - Transmit Packet Ready
Bit 6 - Clear Data Toggle
Bit 1 - Data Toggle Write Enable
Bit 3 - Force Data Toggle
Bit 4 - DMA Request Enable
Bit 6 - Isochronous Transfers
Bits 0:10 - Maximum Payload
Bit 0 - Receive Packet Ready
Bit 7 - Clear Data Toggle
Bit 2 - Data Toggle Write Enable
Bit 5 - DMA Request Enable
Bit 6 - Isochronous Transfers
Bits 0:12 - Receive Packet Count
Get enumerated values variant
Checks if the value of the field is CTRL
Checks if the value of the field is ISOC
Checks if the value of the field is BULK
Checks if the value of the field is INT
Get enumerated values variant
Checks if the value of the field is DFLT
Checks if the value of the field is FULL
Checks if the value of the field is LOW
Bits 0:3 - Target Endpoint Number
Bits 6:7 - Operating Speed
Get enumerated values variant
Checks if the value of the field is CTRL
Checks if the value of the field is ISOC
Checks if the value of the field is BULK
Checks if the value of the field is INT
Get enumerated values variant
Checks if the value of the field is DFLT
Checks if the value of the field is FULL
Checks if the value of the field is LOW
Bits 0:3 - Target Endpoint Number
Bits 6:7 - Operating Speed
Bits 0:10 - Maximum Payload
Bit 0 - Transmit Packet Ready
Bit 6 - Clear Data Toggle
Bit 1 - Data Toggle Write Enable
Bit 3 - Force Data Toggle
Bit 4 - DMA Request Enable
Bit 6 - Isochronous Transfers
Bits 0:10 - Maximum Payload
Bit 0 - Receive Packet Ready
Bit 7 - Clear Data Toggle
Bit 2 - Data Toggle Write Enable
Bit 5 - DMA Request Enable
Bit 6 - Isochronous Transfers
Bits 0:12 - Receive Packet Count
Get enumerated values variant
Checks if the value of the field is CTRL
Checks if the value of the field is ISOC
Checks if the value of the field is BULK
Checks if the value of the field is INT
Get enumerated values variant
Checks if the value of the field is DFLT
Checks if the value of the field is FULL
Checks if the value of the field is LOW
Bits 0:3 - Target Endpoint Number
Bits 6:7 - Operating Speed
Get enumerated values variant
Checks if the value of the field is CTRL
Checks if the value of the field is ISOC
Checks if the value of the field is BULK
Checks if the value of the field is INT
Get enumerated values variant
Checks if the value of the field is DFLT
Checks if the value of the field is FULL
Checks if the value of the field is LOW
Bits 0:3 - Target Endpoint Number
Bits 6:7 - Operating Speed
Bits 0:10 - Maximum Payload
Bit 0 - Transmit Packet Ready
Bit 6 - Clear Data Toggle
Bit 1 - Data Toggle Write Enable
Bit 3 - Force Data Toggle
Bit 4 - DMA Request Enable
Bit 6 - Isochronous Transfers
Bits 0:10 - Maximum Payload
Bit 0 - Receive Packet Ready
Bit 7 - Clear Data Toggle
Bit 2 - Data Toggle Write Enable
Bit 5 - DMA Request Enable
Bit 6 - Isochronous Transfers
Bits 0:12 - Receive Packet Count
Get enumerated values variant
Checks if the value of the field is CTRL
Checks if the value of the field is ISOC
Checks if the value of the field is BULK
Checks if the value of the field is INT
Get enumerated values variant
Checks if the value of the field is DFLT
Checks if the value of the field is FULL
Checks if the value of the field is LOW
Bits 0:3 - Target Endpoint Number
Bits 6:7 - Operating Speed
Get enumerated values variant
Checks if the value of the field is CTRL
Checks if the value of the field is ISOC
Checks if the value of the field is BULK
Checks if the value of the field is INT
Get enumerated values variant
Checks if the value of the field is DFLT
Checks if the value of the field is FULL
Checks if the value of the field is LOW
Bits 0:3 - Target Endpoint Number
Bits 6:7 - Operating Speed
Bits 0:10 - Maximum Payload
Bit 0 - Transmit Packet Ready
Bit 6 - Clear Data Toggle
Bit 1 - Data Toggle Write Enable
Bit 3 - Force Data Toggle
Bit 4 - DMA Request Enable
Bit 6 - Isochronous Transfers
Bits 0:10 - Maximum Payload
Bit 0 - Receive Packet Ready
Bit 7 - Clear Data Toggle
Bit 2 - Data Toggle Write Enable
Bit 5 - DMA Request Enable
Bit 6 - Isochronous Transfers
Bits 0:12 - Receive Packet Count
Get enumerated values variant
Checks if the value of the field is CTRL
Checks if the value of the field is ISOC
Checks if the value of the field is BULK
Checks if the value of the field is INT
Get enumerated values variant
Checks if the value of the field is DFLT
Checks if the value of the field is FULL
Checks if the value of the field is LOW
Bits 0:3 - Target Endpoint Number
Bits 6:7 - Operating Speed
Get enumerated values variant
Checks if the value of the field is CTRL
Checks if the value of the field is ISOC
Checks if the value of the field is BULK
Checks if the value of the field is INT
Get enumerated values variant
Checks if the value of the field is DFLT
Checks if the value of the field is FULL
Checks if the value of the field is LOW
Bits 0:3 - Target Endpoint Number
Bits 6:7 - Operating Speed
Bits 0:10 - Maximum Payload
Bit 0 - Transmit Packet Ready
Bit 6 - Clear Data Toggle
Bit 1 - Data Toggle Write Enable
Bit 3 - Force Data Toggle
Bit 4 - DMA Request Enable
Bit 6 - Isochronous Transfers
Bits 0:10 - Maximum Payload
Bit 0 - Receive Packet Ready
Bit 7 - Clear Data Toggle
Bit 2 - Data Toggle Write Enable
Bit 5 - DMA Request Enable
Bit 6 - Isochronous Transfers
Bits 0:12 - Receive Packet Count
Get enumerated values variant
Checks if the value of the field is CTRL
Checks if the value of the field is ISOC
Checks if the value of the field is BULK
Checks if the value of the field is INT
Get enumerated values variant
Checks if the value of the field is DFLT
Checks if the value of the field is FULL
Checks if the value of the field is LOW
Bits 0:3 - Target Endpoint Number
Bits 6:7 - Operating Speed
Get enumerated values variant
Checks if the value of the field is CTRL
Checks if the value of the field is ISOC
Checks if the value of the field is BULK
Checks if the value of the field is INT
Get enumerated values variant
Checks if the value of the field is DFLT
Checks if the value of the field is FULL
Checks if the value of the field is LOW
Bits 0:3 - Target Endpoint Number
Bits 6:7 - Operating Speed
Bits 0:15 - Block Transfer Packet Count
Bits 0:15 - Block Transfer Packet Count
Bits 0:15 - Block Transfer Packet Count
Bits 0:15 - Block Transfer Packet Count
Bit 1 - EP1 RX Double-Packet Buffer Disable
Bit 2 - EP2 RX Double-Packet Buffer Disable
Bit 3 - EP3 RX Double-Packet Buffer Disable
Bit 4 - EP4 RX Double-Packet Buffer Disable
Bit 5 - EP5 RX Double-Packet Buffer Disable
Bit 6 - EP6 RX Double-Packet Buffer Disable
Bit 7 - EP7 RX Double-Packet Buffer Disable
Bit 1 - EP1 TX Double-Packet Buffer Disable
Bit 2 - EP2 TX Double-Packet Buffer Disable
Bit 3 - EP3 TX Double-Packet Buffer Disable
Bit 4 - EP4 TX Double-Packet Buffer Disable
Bit 5 - EP5 TX Double-Packet Buffer Disable
Bit 6 - EP6 TX Double-Packet Buffer Disable
Bit 7 - EP7 TX Double-Packet Buffer Disable
Get enumerated values variant
Checks if the value of the field is LOW
Checks if the value of the field is HIGH
Checks if the value of the field is VBLOW
Checks if the value of the field is VBHIGH
Get enumerated values variant
Checks if the value of the field is UNCHG
Checks if the value of the field is TRIS
Checks if the value of the field is LOW
Checks if the value of the field is HIGH
Bits 0:1 - External Power Supply Enable Configuration
Bit 2 - EPEN Drive Enable
Bit 4 - Power Fault Input Enable
Bit 5 - Power Fault Sense
Bit 6 - Power Fault Action Enable
Bits 8:9 - Power Fault Action
Bit 0 - USB Power Fault Interrupt Status
Bit 0 - USB Power Fault Interrupt Mask
Bit 0 - USB Power Fault Interrupt Status and Clear
Bit 0 - RESUME Interrupt Status
Bit 0 - RESUME Interrupt Mask
Bit 1 - Enable Device Mode
Bit 0 - VBUS Droop Enable
Bit 0 - VBUS Droop Raw Interrupt Status
Bit 0 - VBUS Droop Interrupt Mask
Bit 0 - VBUS Droop Interrupt Status and Clear
Bit 0 - ID Valid Detect Raw Interrupt Status
Bit 0 - ID Valid Detect Interrupt Mask
Bit 0 - ID Valid Detect Interrupt Status and Clear
Bits 0:3 - DMA A RX Select
Bits 4:7 - DMA A TX Select
Bits 8:11 - DMA B RX Select
Bits 12:15 - DMA B TX Select
Bits 16:19 - DMA C RX Select
Bits 20:23 - DMA C TX Select
Get enumerated values variant
Checks if the value of the field is _0
Get enumerated values variant
Checks if the value of the field is DEVICE
Checks if the value of the field is HOSTDEVICE
Checks if the value of the field is OTG
Bits 0:3 - Controller Type
Bits 6:7 - USB Capability
Bits 8:15 - Endpoint Count
Bits 0:15 - Number of 32-Bit Words
Bits 16:26 - Number of 16-Word Blocks
Bits 0:15 - Current Block
Bits 0:3 - Current Address Offset
Bits 0:31 - EEPROM Read or Write Data
Bits 0:31 - EEPROM Read or Write Data with Increment
Bit 2 - Working on an Erase
Bit 3 - Working on a Copy
Bit 4 - Write Without Permission
Bit 2 - Erase Must Be Retried
Bit 3 - Programming Must Be Retried
Bits 0:31 - EEPROM Unlock
Get enumerated values variant
Checks if the value of the field is RWNPW
Checks if the value of the field is RWPW
Checks if the value of the field is RONPW
Bits 0:2 - Protection Control
Bit 0 - Floating-Point Input Denormal Exception Raw Interrupt Status
Bit 1 - Floating-Point Divide By 0 Exception Raw Interrupt Status
Bit 2 - Floating-Point Invalid Operation Raw Interrupt Status
Bit 3 - Floating-Point Underflow Exception Raw Interrupt Status
Bit 4 - Floating-Point Overflow Exception Raw Interrupt Status
Bit 5 - Floating-Point Inexact Exception Raw Interrupt Status
Bit 0 - Floating-Point Input Denormal Exception Interrupt Mask
Bit 1 - Floating-Point Divide By 0 Exception Interrupt Mask
Bit 2 - Floating-Point Invalid Operation Interrupt Mask
Bit 3 - Floating-Point Underflow Exception Interrupt Mask
Bit 4 - Floating-Point Overflow Exception Interrupt Mask
Bit 5 - Floating-Point Inexact Exception Interrupt Mask
Bit 0 - Floating-Point Input Denormal Exception Masked Interrupt Status
Bit 1 - Floating-Point Divide By 0 Exception Masked Interrupt Status
Bit 2 - Floating-Point Invalid Operation Masked Interrupt Status
Bit 3 - Floating-Point Underflow Exception Masked Interrupt Status
Bit 4 - Floating-Point Overflow Exception Masked Interrupt Status
Bit 5 - Floating-Point Inexact Exception Masked Interrupt Status
Get enumerated values variant
Checks if the value of the field is _1_9V
Checks if the value of the field is _2_1V
Checks if the value of the field is _2_3V
Checks if the value of the field is _2_5V
Bit 1 - Hibernation Request
Bit 3 - RTC Wake-up Enable
Bit 4 - External Wake Pin Enable
Bit 7 - Power Cut Abort Enable
Bit 9 - Wake on Low Battery
Bit 10 - Check Battery Status
Bits 13:14 - Select for Low-Battery Comparator
Bit 16 - Oscillator Bypass
Bit 17 - Oscillator Drive Capability
Bit 31 - Write Complete/Capable
Bit 0 - RTC Alert 0 Interrupt Mask
Bit 2 - Low Battery Voltage Interrupt Mask
Bit 3 - External Wake-Up Interrupt Mask
Bit 4 - External Write Complete/Capable Interrupt Mask
Bit 0 - RTC Alert 0 Raw Interrupt Status
Bit 2 - Low Battery Voltage Raw Interrupt Status
Bit 3 - External Wake-Up Raw Interrupt Status
Bit 4 - Write Complete/Capable Raw Interrupt Status
Bit 0 - RTC Alert 0 Masked Interrupt Status
Bit 2 - Low Battery Voltage Masked Interrupt Status
Bit 3 - External Wake-Up Masked Interrupt Status
Bit 4 - Write Complete/Capable Masked Interrupt Status
Bit 0 - RTC Alert0 Masked Interrupt Clear
Bit 2 - Low Battery Voltage Interrupt Clear
Bit 3 - External Wake-Up Interrupt Clear
Bit 4 - Write Complete/Capable Interrupt Clear
Bits 0:15 - RTC Trim Value
Bits 0:14 - RTC Sub Seconds Count
Bits 16:30 - RTC Sub Seconds Match
Bits 0:31 - Hibernation Module NV Data
Bits 0:17 - Address Offset
Bit 0 - Write a Word into Flash Memory
Bit 1 - Erase a Page of Flash Memory
Bit 2 - Mass Erase Flash Memory
Bit 3 - Commit Register Value
Bits 17:31 - FLASH write key
Bit 0 - Access Raw Interrupt Status
Bit 1 - Programming Raw Interrupt Status
Bit 2 - EEPROM Raw Interrupt Status
Bit 9 - Pump Voltage Raw Interrupt Status
Bit 10 - Invalid Data Raw Interrupt Status
Bit 11 - Erase Verify Error Raw Interrupt Status
Bit 13 - Program Verify Error Raw Interrupt Status
Bit 0 - Access Interrupt Mask
Bit 1 - Programming Interrupt Mask
Bit 2 - EEPROM Interrupt Mask
Bit 9 - VOLT Interrupt Mask
Bit 10 - Invalid Data Interrupt Mask
Bit 11 - ERVER Interrupt Mask
Bit 13 - PROGVER Interrupt Mask
Bit 0 - Access Masked Interrupt Status and Clear
Bit 1 - Programming Masked Interrupt Status and Clear
Bit 2 - EEPROM Masked Interrupt Status and Clear
Bit 9 - VOLT Masked Interrupt Status and Clear
Bit 10 - Invalid Data Masked Interrupt Status and Clear
Bit 11 - ERVER Masked Interrupt Status and Clear
Bit 13 - PROGVER Masked Interrupt Status and Clear
Bit 0 - Buffered Flash Memory Write
Bits 17:31 - FLASH write key
Bits 0:31 - Flash Memory Write Buffer
Get enumerated values variant
Checks if the value of the field is _256KB
Get enumerated values variant
Checks if the value of the field is _32KB
Get enumerated values variant
Checks if the value of the field is _0
Checks if the value of the field is _1
Checks if the value of the field is _2
Checks if the value of the field is _3
Checks if the value of the field is _4
Checks if the value of the field is _5
Checks if the value of the field is _6
Checks if the value of the field is _7
Get enumerated values variant
Checks if the value of the field is A
Checks if the value of the field is B
Checks if the value of the field is C
Checks if the value of the field is D
Checks if the value of the field is E
Checks if the value of the field is F
Checks if the value of the field is G
Checks if the value of the field is H
Bit 9 - Boot GPIO Polarity
Bits 10:12 - Boot GPIO Pin
Bits 13:15 - Boot GPIO Port
Get enumerated values variant
Checks if the value of the field is _0
Checks if the value of the field is _1
Checks if the value of the field is _2
Get enumerated values variant
Checks if the value of the field is REVA
Checks if the value of the field is REVB
Checks if the value of the field is REVC
Get enumerated values variant
Checks if the value of the field is TM4C123
Get enumerated values variant
Checks if the value of the field is _1
Bits 0:7 - Minor Revision
Bits 8:15 - Major Revision
Bits 16:23 - Device Class
Bits 28:30 - DID0 Version
Get enumerated values variant
Checks if the value of the field is ES
Checks if the value of the field is PP
Checks if the value of the field is FQ
Get enumerated values variant
Checks if the value of the field is QFP
Checks if the value of the field is BGA
Get enumerated values variant
Checks if the value of the field is I
Checks if the value of the field is E
Checks if the value of the field is IE
Get enumerated values variant
Checks if the value of the field is _100
Checks if the value of the field is _64
Checks if the value of the field is _144
Checks if the value of the field is _157
Checks if the value of the field is _128
Bits 0:1 - Qualification Status
Bits 5:7 - Temperature Range
Bits 13:15 - Package Pin Count
Bits 28:31 - DID1 Version
Get enumerated values variant
Checks if the value of the field is _8KB
Checks if the value of the field is _16KB
Checks if the value of the field is _32KB
Checks if the value of the field is _64KB
Checks if the value of the field is _96KB
Checks if the value of the field is _128K
Checks if the value of the field is _192K
Checks if the value of the field is _256K
Get enumerated values variant
Checks if the value of the field is _2KB
Checks if the value of the field is _4KB
Checks if the value of the field is _6KB
Checks if the value of the field is _8KB
Checks if the value of the field is _12KB
Checks if the value of the field is _16KB
Checks if the value of the field is _20KB
Checks if the value of the field is _24KB
Checks if the value of the field is _32KB
Get enumerated values variant
Checks if the value of the field is _125K
Checks if the value of the field is _250K
Checks if the value of the field is _500K
Checks if the value of the field is _1M
Get enumerated values variant
Checks if the value of the field is _125K
Checks if the value of the field is _250K
Checks if the value of the field is _500K
Checks if the value of the field is _1M
Get enumerated values variant
Checks if the value of the field is _80
Checks if the value of the field is _50
Checks if the value of the field is _40
Checks if the value of the field is _25
Checks if the value of the field is _20
Bit 2 - SWO Trace Port Present
Bit 3 - Watchdog Timer 0 Present
Bit 5 - Temp Sensor Present
Bit 6 - Hibernation Module Present
Bits 8:9 - Max ADC0 Speed
Bits 10:11 - Max ADC1 Speed
Bits 12:15 - System Clock Divider
Bit 16 - ADC Module 0 Present
Bit 17 - ADC Module 1 Present
Bit 20 - PWM Module 0 Present
Bit 21 - PWM Module 1 Present
Bit 24 - CAN Module 0 Present
Bit 25 - CAN Module 1 Present
Bit 28 - Watchdog Timer1 Present
Bit 0 - UART Module 0 Present
Bit 1 - UART Module 1 Present
Bit 2 - UART Module 2 Present
Bit 4 - SSI Module 0 Present
Bit 5 - SSI Module 1 Present
Bit 8 - QEI Module 0 Present
Bit 9 - QEI Module 1 Present
Bit 12 - I2C Module 0 Present
Bit 13 - I2C Module 0 Speed
Bit 14 - I2C Module 1 Present
Bit 15 - I2C Module 1 Speed
Bit 16 - Timer Module 0 Present
Bit 17 - Timer Module 1 Present
Bit 18 - Timer Module 2 Present
Bit 19 - Timer Module 3 Present
Bit 24 - Analog Comparator 0 Present
Bit 25 - Analog Comparator 1 Present
Bit 26 - Analog Comparator 2 Present
Bit 28 - I2S Module 0 Present
Bit 30 - EPI Module 0 Present
Bit 15 - PWM Fault Pin Present
Bit 16 - ADC Module 0 AIN0 Pin Present
Bit 17 - ADC Module 0 AIN1 Pin Present
Bit 18 - ADC Module 0 AIN2 Pin Present
Bit 19 - ADC Module 0 AIN3 Pin Present
Bit 20 - ADC Module 0 AIN4 Pin Present
Bit 21 - ADC Module 0 AIN5 Pin Present
Bit 22 - ADC Module 0 AIN6 Pin Present
Bit 23 - ADC Module 0 AIN7 Pin Present
Bit 24 - T0CCP0 Pin Present
Bit 25 - T0CCP1 Pin Present
Bit 26 - T1CCP0 Pin Present
Bit 27 - T1CCP1 Pin Present
Bit 28 - T2CCP0 Pin Present
Bit 29 - T2CCP1 Pin Present
Bit 31 - 32KHz Input Clock Available
Bit 0 - GPIO Port A Present
Bit 1 - GPIO Port B Present
Bit 2 - GPIO Port C Present
Bit 3 - GPIO Port D Present
Bit 4 - GPIO Port E Present
Bit 5 - GPIO Port F Present
Bit 6 - GPIO Port G Present
Bit 7 - GPIO Port H Present
Bit 8 - GPIO Port J Present
Bit 12 - Internal Code ROM Present
Bit 13 - Micro-DMA Module Present
Bit 14 - T3CCP0 Pin Present
Bit 15 - T3CCP1 Pin Present
Bit 28 - Ethernet MAC Layer 0 Present
Bit 30 - Ethernet PHY Layer 0 Present
Bit 20 - PWM Extended SYNC Active
Bit 21 - PWM Extended Fault Active
Bit 24 - PWM Fault 0 Pin Present
Bit 25 - PWM Fault 1 Pin Present
Bit 26 - PWM Fault 2 Pin Present
Bit 27 - PWM Fault 3 Pin Present
Get enumerated values variant
Checks if the value of the field is DEV
Checks if the value of the field is HOSTDEV
Checks if the value of the field is OTG
Bits 0:1 - USB Module 0 Present
Bit 4 - USB Module 0 PHY Present
Bit 0 - ADC Module 0 AIN0 Pin Present
Bit 1 - ADC Module 0 AIN1 Pin Present
Bit 2 - ADC Module 0 AIN2 Pin Present
Bit 3 - ADC Module 0 AIN3 Pin Present
Bit 4 - ADC Module 0 AIN4 Pin Present
Bit 5 - ADC Module 0 AIN5 Pin Present
Bit 6 - ADC Module 0 AIN6 Pin Present
Bit 7 - ADC Module 0 AIN7 Pin Present
Bit 8 - ADC Module 0 AIN8 Pin Present
Bit 9 - ADC Module 0 AIN9 Pin Present
Bit 10 - ADC Module 0 AIN10 Pin Present
Bit 11 - ADC Module 0 AIN11 Pin Present
Bit 12 - ADC Module 0 AIN12 Pin Present
Bit 13 - ADC Module 0 AIN13 Pin Present
Bit 14 - ADC Module 0 AIN14 Pin Present
Bit 15 - ADC Module 0 AIN15 Pin Present
Bit 16 - ADC Module 1 AIN0 Pin Present
Bit 17 - ADC Module 1 AIN1 Pin Present
Bit 18 - ADC Module 1 AIN2 Pin Present
Bit 19 - ADC Module 1 AIN3 Pin Present
Bit 20 - ADC Module 1 AIN4 Pin Present
Bit 21 - ADC Module 1 AIN5 Pin Present
Bit 22 - ADC Module 1 AIN6 Pin Present
Bit 23 - ADC Module 1 AIN7 Pin Present
Bit 24 - ADC Module 1 AIN8 Pin Present
Bit 25 - ADC Module 1 AIN9 Pin Present
Bit 26 - ADC Module 1 AIN10 Pin Present
Bit 27 - ADC Module 1 AIN11 Pin Present
Bit 28 - ADC Module 1 AIN12 Pin Present
Bit 29 - ADC Module 1 AIN13 Pin Present
Bit 30 - ADC Module 1 AIN14 Pin Present
Bit 31 - ADC Module 1 AIN15 Pin Present
Bit 1 - VDD under BOR1 Event Action
Bit 2 - VDD under BOR0 Event Action
Bit 3 - WDT0 Reset Control
Bit 6 - HIB Reset Control
Bit 16 - ADC0 Reset Control
Bit 17 - ADC1 Reset Control
Bit 20 - PWM Reset Control
Bit 24 - CAN0 Reset Control
Bit 25 - CAN1 Reset Control
Bit 28 - WDT1 Reset Control
Bit 0 - UART0 Reset Control
Bit 1 - UART1 Reset Control
Bit 2 - UART2 Reset Control
Bit 4 - SSI0 Reset Control
Bit 5 - SSI1 Reset Control
Bit 8 - QEI0 Reset Control
Bit 9 - QEI1 Reset Control
Bit 12 - I2C0 Reset Control
Bit 14 - I2C1 Reset Control
Bit 16 - Timer 0 Reset Control
Bit 17 - Timer 1 Reset Control
Bit 18 - Timer 2 Reset Control
Bit 19 - Timer 3 Reset Control
Bit 24 - Analog Comp 0 Reset Control
Bit 25 - Analog Comp 1 Reset Control
Bit 0 - Port A Reset Control
Bit 1 - Port B Reset Control
Bit 2 - Port C Reset Control
Bit 3 - Port D Reset Control
Bit 4 - Port E Reset Control
Bit 5 - Port F Reset Control
Bit 13 - Micro-DMA Reset Control
Bit 16 - USB0 Reset Control
Bit 1 - VDD under BOR1 Raw Interrupt Status
Bit 3 - Main Oscillator Failure Raw Interrupt Status
Bit 6 - PLL Lock Raw Interrupt Status
Bit 7 - USB PLL Lock Raw Interrupt Status
Bit 8 - MOSC Power Up Raw Interrupt Status
Bit 10 - VDDA Power OK Event Raw Interrupt Status
Bit 11 - VDD under BOR0 Raw Interrupt Status
Bit 1 - VDD under BOR1 Interrupt Mask
Bit 3 - Main Oscillator Failure Interrupt Mask
Bit 6 - PLL Lock Interrupt Mask
Bit 7 - USB PLL Lock Interrupt Mask
Bit 8 - MOSC Power Up Interrupt Mask
Bit 10 - VDDA Power OK Interrupt Mask
Bit 11 - VDD under BOR0 Interrupt Mask
Bit 1 - VDD under BOR1 Masked Interrupt Status
Bit 3 - Main Oscillator Failure Masked Interrupt Status
Bit 6 - PLL Lock Masked Interrupt Status
Bit 7 - USB PLL Lock Masked Interrupt Status
Bit 8 - MOSC Power Up Masked Interrupt Status
Bit 10 - VDDA Power OK Masked Interrupt Status
Bit 11 - VDD under BOR0 Masked Interrupt Status
Bit 3 - Watchdog Timer 0 Reset
Bit 5 - Watchdog Timer 1 Reset
Bit 16 - MOSC Failure Reset
Get enumerated values variant
Checks if the value of the field is MAIN
Checks if the value of the field is INT
Checks if the value of the field is INT4
Checks if the value of the field is _30
Get enumerated values variant
Checks if the value of the field is _4MHZ
Checks if the value of the field is _4_09MHZ
Checks if the value of the field is _4_91MHZ
Checks if the value of the field is _5MHZ
Checks if the value of the field is _5_12MHZ
Checks if the value of the field is _6MHZ
Checks if the value of the field is _6_14MHZ
Checks if the value of the field is _7_37MHZ
Checks if the value of the field is _8MHZ
Checks if the value of the field is _8_19MHZ
Checks if the value of the field is _10MHZ
Checks if the value of the field is _12MHZ
Checks if the value of the field is _12_2MHZ
Checks if the value of the field is _13_5MHZ
Checks if the value of the field is _14_3MHZ
Checks if the value of the field is _16MHZ
Checks if the value of the field is _16_3MHZ
Checks if the value of the field is _18MHZ
Checks if the value of the field is _20MHZ
Checks if the value of the field is _24MHZ
Checks if the value of the field is _25MHZ
Get enumerated values variant
Checks if the value of the field is _2
Checks if the value of the field is _4
Checks if the value of the field is _8
Checks if the value of the field is _16
Checks if the value of the field is _32
Checks if the value of the field is _64
Bit 0 - Main Oscillator Disable
Bits 4:5 - Oscillator Source
Bits 6:10 - Crystal Value
Bits 17:19 - PWM Unit Clock Divisor
Bit 20 - Enable PWM Clock Divisor
Bit 22 - Enable System Clock Divider
Bits 23:26 - System Clock Divisor
Bit 27 - Auto Clock Gating
Bit 0 - Port A Advanced High-Performance Bus
Bit 1 - Port B Advanced High-Performance Bus
Bit 2 - Port C Advanced High-Performance Bus
Bit 3 - Port D Advanced High-Performance Bus
Bit 4 - Port E Advanced High-Performance Bus
Bit 5 - Port F Advanced High-Performance Bus
Get enumerated values variant
Checks if the value of the field is MO
Checks if the value of the field is IO
Checks if the value of the field is IO4
Checks if the value of the field is _30
Checks if the value of the field is _32
Bits 4:6 - Oscillator Source 2
Bit 13 - Power-Down PLL 2
Bit 14 - Power-Down USB PLL
Bit 22 - Additional LSB for SYSDIV2
Bits 23:28 - System Clock Divisor 2
Bit 30 - Divide PLL as 400 MHz vs. 200 MHz
Bit 0 - Clock Validation for MOSC
Bit 1 - MOSC Failure Action
Bit 2 - No Crystal Connected
Get enumerated values variant
Checks if the value of the field is _125K
Checks if the value of the field is _250K
Checks if the value of the field is _500K
Checks if the value of the field is _1M
Get enumerated values variant
Checks if the value of the field is _125K
Checks if the value of the field is _250K
Checks if the value of the field is _500K
Checks if the value of the field is _1M
Bit 3 - WDT0 Clock Gating Control
Bit 6 - HIB Clock Gating Control
Bits 8:9 - ADC0 Sample Speed
Bits 10:11 - ADC1 Sample Speed
Bit 16 - ADC0 Clock Gating Control
Bit 17 - ADC1 Clock Gating Control
Bit 20 - PWM Clock Gating Control
Bit 24 - CAN0 Clock Gating Control
Bit 25 - CAN1 Clock Gating Control
Bit 28 - WDT1 Clock Gating Control
Bit 0 - UART0 Clock Gating Control
Bit 1 - UART1 Clock Gating Control
Bit 2 - UART2 Clock Gating Control
Bit 4 - SSI0 Clock Gating Control
Bit 5 - SSI1 Clock Gating Control
Bit 8 - QEI0 Clock Gating Control
Bit 9 - QEI1 Clock Gating Control
Bit 12 - I2C0 Clock Gating Control
Bit 14 - I2C1 Clock Gating Control
Bit 16 - Timer 0 Clock Gating Control
Bit 17 - Timer 1 Clock Gating Control
Bit 18 - Timer 2 Clock Gating Control
Bit 19 - Timer 3 Clock Gating Control
Bit 24 - Analog Comparator 0 Clock Gating
Bit 25 - Analog Comparator 1 Clock Gating
Bit 0 - Port A Clock Gating Control
Bit 1 - Port B Clock Gating Control
Bit 2 - Port C Clock Gating Control
Bit 3 - Port D Clock Gating Control
Bit 4 - Port E Clock Gating Control
Bit 5 - Port F Clock Gating Control
Bit 13 - Micro-DMA Clock Gating Control
Bit 16 - USB0 Clock Gating Control
Bit 3 - WDT0 Clock Gating Control
Bit 6 - HIB Clock Gating Control
Bit 16 - ADC0 Clock Gating Control
Bit 17 - ADC1 Clock Gating Control
Bit 20 - PWM Clock Gating Control
Bit 24 - CAN0 Clock Gating Control
Bit 25 - CAN1 Clock Gating Control
Bit 28 - WDT1 Clock Gating Control
Bit 0 - UART0 Clock Gating Control
Bit 1 - UART1 Clock Gating Control
Bit 2 - UART2 Clock Gating Control
Bit 4 - SSI0 Clock Gating Control
Bit 5 - SSI1 Clock Gating Control
Bit 8 - QEI0 Clock Gating Control
Bit 9 - QEI1 Clock Gating Control
Bit 12 - I2C0 Clock Gating Control
Bit 14 - I2C1 Clock Gating Control
Bit 16 - Timer 0 Clock Gating Control
Bit 17 - Timer 1 Clock Gating Control
Bit 18 - Timer 2 Clock Gating Control
Bit 19 - Timer 3 Clock Gating Control
Bit 24 - Analog Comparator 0 Clock Gating
Bit 25 - Analog Comparator 1 Clock Gating
Bit 0 - Port A Clock Gating Control
Bit 1 - Port B Clock Gating Control
Bit 2 - Port C Clock Gating Control
Bit 3 - Port D Clock Gating Control
Bit 4 - Port E Clock Gating Control
Bit 5 - Port F Clock Gating Control
Bit 13 - Micro-DMA Clock Gating Control
Bit 16 - USB0 Clock Gating Control
Bit 3 - WDT0 Clock Gating Control
Bit 6 - HIB Clock Gating Control
Bit 16 - ADC0 Clock Gating Control
Bit 17 - ADC1 Clock Gating Control
Bit 20 - PWM Clock Gating Control
Bit 24 - CAN0 Clock Gating Control
Bit 25 - CAN1 Clock Gating Control
Bit 28 - WDT1 Clock Gating Control
Bit 0 - UART0 Clock Gating Control
Bit 1 - UART1 Clock Gating Control
Bit 2 - UART2 Clock Gating Control
Bit 4 - SSI0 Clock Gating Control
Bit 5 - SSI1 Clock Gating Control
Bit 8 - QEI0 Clock Gating Control
Bit 9 - QEI1 Clock Gating Control
Bit 12 - I2C0 Clock Gating Control
Bit 14 - I2C1 Clock Gating Control
Bit 16 - Timer 0 Clock Gating Control
Bit 17 - Timer 1 Clock Gating Control
Bit 18 - Timer 2 Clock Gating Control
Bit 19 - Timer 3 Clock Gating Control
Bit 24 - Analog Comparator 0 Clock Gating
Bit 25 - Analog Comparator 1 Clock Gating
Bit 0 - Port A Clock Gating Control
Bit 1 - Port B Clock Gating Control
Bit 2 - Port C Clock Gating Control
Bit 3 - Port D Clock Gating Control
Bit 4 - Port E Clock Gating Control
Bit 5 - Port F Clock Gating Control
Bit 13 - Micro-DMA Clock Gating Control
Bit 16 - USB0 Clock Gating Control
Get enumerated values variant
Checks if the value of the field is IGN
Checks if the value of the field is IO
Checks if the value of the field is _30
Checks if the value of the field is _32
Bit 1 - PIOSC Power Down Request
Bits 23:28 - Divider Field Override
Bits 0:6 - User Trim Value
Bit 9 - Start Calibration
Bit 31 - Use User Trim Value
Get enumerated values variant
Checks if the value of the field is CRNONE
Checks if the value of the field is CRPASS
Checks if the value of the field is CRFAIL
Bits 0:6 - Calibration Trim Value
Bits 8:9 - Calibration Result
Bits 16:22 - Default Trim Value
Bits 0:9 - PLL M Integer Value
Bits 10:19 - PLL M Fractional Value
Get enumerated values variant
Checks if the value of the field is NRM
Checks if the value of the field is SBY
Checks if the value of the field is LP
Get enumerated values variant
Checks if the value of the field is NRM
Checks if the value of the field is SLP
Bits 0:1 - SRAM Power Modes
Bits 4:5 - Flash Power Modes
Get enumerated values variant
Checks if the value of the field is NRM
Checks if the value of the field is SBY
Checks if the value of the field is LP
Get enumerated values variant
Checks if the value of the field is NRM
Checks if the value of the field is SLP
Bits 0:1 - SRAM Power Modes
Bits 4:5 - Flash Power Modes
Bit 16 - ADC1 DC0 Present
Bit 17 - ADC1 DC1 Present
Bit 18 - ADC1 DC2 Present
Bit 19 - ADC1 DC3 Present
Bit 20 - ADC1 DC4 Present
Bit 21 - ADC1 DC5 Present
Bit 22 - ADC1 DC6 Present
Bit 23 - ADC1 DC7 Present
Bit 0 - 32 Word Flash Write Buffer Available
Get enumerated values variant
Checks if the value of the field is _0_90V
Checks if the value of the field is _0_95V
Checks if the value of the field is _1_00V
Checks if the value of the field is _1_05V
Checks if the value of the field is _1_10V
Checks if the value of the field is _1_15V
Checks if the value of the field is _1_20V
Bits 0:7 - LDO Output Voltage
Bit 31 - Voltage Adjust Enable
Get enumerated values variant
Checks if the value of the field is _0_90V
Checks if the value of the field is _0_95V
Checks if the value of the field is _1_00V
Checks if the value of the field is _1_05V
Checks if the value of the field is _1_10V
Checks if the value of the field is _1_15V
Checks if the value of the field is _1_20V
Bits 0:7 - LDO Output Voltage
Bit 31 - Voltage Adjust Enable
Bit 0 - Watchdog Timer 0 Present
Bit 1 - Watchdog Timer 1 Present
Bit 0 - 16/32-Bit General-Purpose Timer 0 Present
Bit 1 - 16/32-Bit General-Purpose Timer 1 Present
Bit 2 - 16/32-Bit General-Purpose Timer 2 Present
Bit 3 - 16/32-Bit General-Purpose Timer 3 Present
Bit 4 - 16/32-Bit General-Purpose Timer 4 Present
Bit 5 - 16/32-Bit General-Purpose Timer 5 Present
Bit 0 - GPIO Port A Present
Bit 1 - GPIO Port B Present
Bit 2 - GPIO Port C Present
Bit 3 - GPIO Port D Present
Bit 4 - GPIO Port E Present
Bit 5 - GPIO Port F Present
Bit 6 - GPIO Port G Present
Bit 7 - GPIO Port H Present
Bit 8 - GPIO Port J Present
Bit 9 - GPIO Port K Present
Bit 10 - GPIO Port L Present
Bit 11 - GPIO Port M Present
Bit 12 - GPIO Port N Present
Bit 13 - GPIO Port P Present
Bit 14 - GPIO Port Q Present
Bit 0 - uDMA Module Present
Bit 0 - Hibernation Module Present
Bit 0 - UART Module 0 Present
Bit 1 - UART Module 1 Present
Bit 2 - UART Module 2 Present
Bit 3 - UART Module 3 Present
Bit 4 - UART Module 4 Present
Bit 5 - UART Module 5 Present
Bit 6 - UART Module 6 Present
Bit 7 - UART Module 7 Present
Bit 0 - SSI Module 0 Present
Bit 1 - SSI Module 1 Present
Bit 2 - SSI Module 2 Present
Bit 3 - SSI Module 3 Present
Bit 0 - I2C Module 0 Present
Bit 1 - I2C Module 1 Present
Bit 2 - I2C Module 2 Present
Bit 3 - I2C Module 3 Present
Bit 4 - I2C Module 4 Present
Bit 5 - I2C Module 5 Present
Bit 0 - USB Module Present
Bit 0 - CAN Module 0 Present
Bit 1 - CAN Module 1 Present
Bit 0 - ADC Module 0 Present
Bit 1 - ADC Module 1 Present
Bit 0 - Analog Comparator Module Present
Bit 0 - PWM Module 0 Present
Bit 1 - PWM Module 1 Present
Bit 0 - QEI Module 0 Present
Bit 1 - QEI Module 1 Present
Bit 0 - EEPROM Module Present
Bit 0 - 32/64-Bit Wide General-Purpose Timer 0 Present
Bit 1 - 32/64-Bit Wide General-Purpose Timer 1 Present
Bit 2 - 32/64-Bit Wide General-Purpose Timer 2 Present
Bit 3 - 32/64-Bit Wide General-Purpose Timer 3 Present
Bit 4 - 32/64-Bit Wide General-Purpose Timer 4 Present
Bit 5 - 32/64-Bit Wide General-Purpose Timer 5 Present
Bit 0 - Watchdog Timer 0 Software Reset
Bit 1 - Watchdog Timer 1 Software Reset
Bit 0 - 16/32-Bit General-Purpose Timer 0 Software Reset
Bit 1 - 16/32-Bit General-Purpose Timer 1 Software Reset
Bit 2 - 16/32-Bit General-Purpose Timer 2 Software Reset
Bit 3 - 16/32-Bit General-Purpose Timer 3 Software Reset
Bit 4 - 16/32-Bit General-Purpose Timer 4 Software Reset
Bit 5 - 16/32-Bit General-Purpose Timer 5 Software Reset
Bit 0 - GPIO Port A Software Reset
Bit 1 - GPIO Port B Software Reset
Bit 2 - GPIO Port C Software Reset
Bit 3 - GPIO Port D Software Reset
Bit 4 - GPIO Port E Software Reset
Bit 5 - GPIO Port F Software Reset
Bit 0 - uDMA Module Software Reset
Bit 0 - Hibernation Module Software Reset
Bit 0 - UART Module 0 Software Reset
Bit 1 - UART Module 1 Software Reset
Bit 2 - UART Module 2 Software Reset
Bit 3 - UART Module 3 Software Reset
Bit 4 - UART Module 4 Software Reset
Bit 5 - UART Module 5 Software Reset
Bit 6 - UART Module 6 Software Reset
Bit 7 - UART Module 7 Software Reset
Bit 0 - SSI Module 0 Software Reset
Bit 1 - SSI Module 1 Software Reset
Bit 2 - SSI Module 2 Software Reset
Bit 3 - SSI Module 3 Software Reset
Bit 0 - I2C Module 0 Software Reset
Bit 1 - I2C Module 1 Software Reset
Bit 2 - I2C Module 2 Software Reset
Bit 3 - I2C Module 3 Software Reset
Bit 0 - USB Module Software Reset
Bit 0 - CAN Module 0 Software Reset
Bit 1 - CAN Module 1 Software Reset
Bit 0 - ADC Module 0 Software Reset
Bit 1 - ADC Module 1 Software Reset
Bit 0 - Analog Comparator Module 0 Software Reset
Bit 0 - PWM Module 0 Software Reset
Bit 1 - PWM Module 1 Software Reset
Bit 0 - QEI Module 0 Software Reset
Bit 1 - QEI Module 1 Software Reset
Bit 0 - EEPROM Module Software Reset
Bit 0 - 32/64-Bit Wide General-Purpose Timer 0 Software Reset
Bit 1 - 32/64-Bit Wide General-Purpose Timer 1 Software Reset
Bit 2 - 32/64-Bit Wide General-Purpose Timer 2 Software Reset
Bit 3 - 32/64-Bit Wide General-Purpose Timer 3 Software Reset
Bit 4 - 32/64-Bit Wide General-Purpose Timer 4 Software Reset
Bit 5 - 32/64-Bit Wide General-Purpose Timer 5 Software Reset
Bit 0 - Watchdog Timer 0 Run Mode Clock Gating Control
Bit 1 - Watchdog Timer 1 Run Mode Clock Gating Control
Bit 0 - 16/32-Bit General-Purpose Timer 0 Run Mode Clock Gating Control
Bit 1 - 16/32-Bit General-Purpose Timer 1 Run Mode Clock Gating Control
Bit 2 - 16/32-Bit General-Purpose Timer 2 Run Mode Clock Gating Control
Bit 3 - 16/32-Bit General-Purpose Timer 3 Run Mode Clock Gating Control
Bit 4 - 16/32-Bit General-Purpose Timer 4 Run Mode Clock Gating Control
Bit 5 - 16/32-Bit General-Purpose Timer 5 Run Mode Clock Gating Control
Bit 0 - GPIO Port A Run Mode Clock Gating Control
Bit 1 - GPIO Port B Run Mode Clock Gating Control
Bit 2 - GPIO Port C Run Mode Clock Gating Control
Bit 3 - GPIO Port D Run Mode Clock Gating Control
Bit 4 - GPIO Port E Run Mode Clock Gating Control
Bit 5 - GPIO Port F Run Mode Clock Gating Control
Bit 0 - uDMA Module Run Mode Clock Gating Control
Bit 0 - Hibernation Module Run Mode Clock Gating Control
Bit 0 - UART Module 0 Run Mode Clock Gating Control
Bit 1 - UART Module 1 Run Mode Clock Gating Control
Bit 2 - UART Module 2 Run Mode Clock Gating Control
Bit 3 - UART Module 3 Run Mode Clock Gating Control
Bit 4 - UART Module 4 Run Mode Clock Gating Control
Bit 5 - UART Module 5 Run Mode Clock Gating Control
Bit 6 - UART Module 6 Run Mode Clock Gating Control
Bit 7 - UART Module 7 Run Mode Clock Gating Control
Bit 0 - SSI Module 0 Run Mode Clock Gating Control
Bit 1 - SSI Module 1 Run Mode Clock Gating Control
Bit 2 - SSI Module 2 Run Mode Clock Gating Control
Bit 3 - SSI Module 3 Run Mode Clock Gating Control
Bit 0 - I2C Module 0 Run Mode Clock Gating Control
Bit 1 - I2C Module 1 Run Mode Clock Gating Control
Bit 2 - I2C Module 2 Run Mode Clock Gating Control
Bit 3 - I2C Module 3 Run Mode Clock Gating Control
Bit 0 - USB Module Run Mode Clock Gating Control
Bit 0 - CAN Module 0 Run Mode Clock Gating Control
Bit 1 - CAN Module 1 Run Mode Clock Gating Control
Bit 0 - ADC Module 0 Run Mode Clock Gating Control
Bit 1 - ADC Module 1 Run Mode Clock Gating Control
Bit 0 - Analog Comparator Module 0 Run Mode Clock Gating Control
Bit 0 - PWM Module 0 Run Mode Clock Gating Control
Bit 1 - PWM Module 1 Run Mode Clock Gating Control
Bit 0 - QEI Module 0 Run Mode Clock Gating Control
Bit 1 - QEI Module 1 Run Mode Clock Gating Control
Bit 0 - EEPROM Module Run Mode Clock Gating Control
Bit 0 - 32/64-Bit Wide General-Purpose Timer 0 Run Mode Clock Gating Control
Bit 1 - 32/64-Bit Wide General-Purpose Timer 1 Run Mode Clock Gating Control
Bit 2 - 32/64-Bit Wide General-Purpose Timer 2 Run Mode Clock Gating Control
Bit 3 - 32/64-Bit Wide General-Purpose Timer 3 Run Mode Clock Gating Control
Bit 4 - 32/64-Bit Wide General-Purpose Timer 4 Run Mode Clock Gating Control
Bit 5 - 32/64-Bit Wide General-Purpose Timer 5 Run Mode Clock Gating Control
Bit 0 - Watchdog Timer 0 Sleep Mode Clock Gating Control
Bit 1 - Watchdog Timer 1 Sleep Mode Clock Gating Control
Bit 0 - 16/32-Bit General-Purpose Timer 0 Sleep Mode Clock Gating Control
Bit 1 - 16/32-Bit General-Purpose Timer 1 Sleep Mode Clock Gating Control
Bit 2 - 16/32-Bit General-Purpose Timer 2 Sleep Mode Clock Gating Control
Bit 3 - 16/32-Bit General-Purpose Timer 3 Sleep Mode Clock Gating Control
Bit 4 - 16/32-Bit General-Purpose Timer 4 Sleep Mode Clock Gating Control
Bit 5 - 16/32-Bit General-Purpose Timer 5 Sleep Mode Clock Gating Control
Bit 0 - GPIO Port A Sleep Mode Clock Gating Control
Bit 1 - GPIO Port B Sleep Mode Clock Gating Control
Bit 2 - GPIO Port C Sleep Mode Clock Gating Control
Bit 3 - GPIO Port D Sleep Mode Clock Gating Control
Bit 4 - GPIO Port E Sleep Mode Clock Gating Control
Bit 5 - GPIO Port F Sleep Mode Clock Gating Control
Bit 0 - uDMA Module Sleep Mode Clock Gating Control
Bit 0 - Hibernation Module Sleep Mode Clock Gating Control
Bit 0 - UART Module 0 Sleep Mode Clock Gating Control
Bit 1 - UART Module 1 Sleep Mode Clock Gating Control
Bit 2 - UART Module 2 Sleep Mode Clock Gating Control
Bit 3 - UART Module 3 Sleep Mode Clock Gating Control
Bit 4 - UART Module 4 Sleep Mode Clock Gating Control
Bit 5 - UART Module 5 Sleep Mode Clock Gating Control
Bit 6 - UART Module 6 Sleep Mode Clock Gating Control
Bit 7 - UART Module 7 Sleep Mode Clock Gating Control
Bit 0 - SSI Module 0 Sleep Mode Clock Gating Control
Bit 1 - SSI Module 1 Sleep Mode Clock Gating Control
Bit 2 - SSI Module 2 Sleep Mode Clock Gating Control
Bit 3 - SSI Module 3 Sleep Mode Clock Gating Control
Bit 0 - I2C Module 0 Sleep Mode Clock Gating Control
Bit 1 - I2C Module 1 Sleep Mode Clock Gating Control
Bit 2 - I2C Module 2 Sleep Mode Clock Gating Control
Bit 3 - I2C Module 3 Sleep Mode Clock Gating Control
Bit 0 - USB Module Sleep Mode Clock Gating Control
Bit 0 - CAN Module 0 Sleep Mode Clock Gating Control
Bit 1 - CAN Module 1 Sleep Mode Clock Gating Control
Bit 0 - ADC Module 0 Sleep Mode Clock Gating Control
Bit 1 - ADC Module 1 Sleep Mode Clock Gating Control
Bit 0 - Analog Comparator Module 0 Sleep Mode Clock Gating Control
Bit 0 - PWM Module 0 Sleep Mode Clock Gating Control
Bit 1 - PWM Module 1 Sleep Mode Clock Gating Control
Bit 0 - QEI Module 0 Sleep Mode Clock Gating Control
Bit 1 - QEI Module 1 Sleep Mode Clock Gating Control
Bit 0 - EEPROM Module Sleep Mode Clock Gating Control
Bit 0 - 32/64-Bit Wide General-Purpose Timer 0 Sleep Mode Clock Gating Control
Bit 1 - 32/64-Bit Wide General-Purpose Timer 1 Sleep Mode Clock Gating Control
Bit 2 - 32/64-Bit Wide General-Purpose Timer 2 Sleep Mode Clock Gating Control
Bit 3 - 32/64-Bit Wide General-Purpose Timer 3 Sleep Mode Clock Gating Control
Bit 4 - 32/64-Bit Wide General-Purpose Timer 4 Sleep Mode Clock Gating Control
Bit 5 - 32/64-Bit Wide General-Purpose Timer 5 Sleep Mode Clock Gating Control
Bit 0 - Watchdog Timer 0 Deep-Sleep Mode Clock Gating Control
Bit 1 - Watchdog Timer 1 Deep-Sleep Mode Clock Gating Control
Bit 0 - 16/32-Bit General-Purpose Timer 0 Deep-Sleep Mode Clock Gating Control
Bit 1 - 16/32-Bit General-Purpose Timer 1 Deep-Sleep Mode Clock Gating Control
Bit 2 - 16/32-Bit General-Purpose Timer 2 Deep-Sleep Mode Clock Gating Control
Bit 3 - 16/32-Bit General-Purpose Timer 3 Deep-Sleep Mode Clock Gating Control
Bit 4 - 16/32-Bit General-Purpose Timer 4 Deep-Sleep Mode Clock Gating Control
Bit 5 - 16/32-Bit General-Purpose Timer 5 Deep-Sleep Mode Clock Gating Control
Bit 0 - GPIO Port A Deep-Sleep Mode Clock Gating Control
Bit 1 - GPIO Port B Deep-Sleep Mode Clock Gating Control
Bit 2 - GPIO Port C Deep-Sleep Mode Clock Gating Control
Bit 3 - GPIO Port D Deep-Sleep Mode Clock Gating Control
Bit 4 - GPIO Port E Deep-Sleep Mode Clock Gating Control
Bit 5 - GPIO Port F Deep-Sleep Mode Clock Gating Control
Bit 0 - uDMA Module Deep-Sleep Mode Clock Gating Control
Bit 0 - Hibernation Module Deep-Sleep Mode Clock Gating Control
Bit 0 - UART Module 0 Deep-Sleep Mode Clock Gating Control
Bit 1 - UART Module 1 Deep-Sleep Mode Clock Gating Control
Bit 2 - UART Module 2 Deep-Sleep Mode Clock Gating Control
Bit 3 - UART Module 3 Deep-Sleep Mode Clock Gating Control
Bit 4 - UART Module 4 Deep-Sleep Mode Clock Gating Control
Bit 5 - UART Module 5 Deep-Sleep Mode Clock Gating Control
Bit 6 - UART Module 6 Deep-Sleep Mode Clock Gating Control
Bit 7 - UART Module 7 Deep-Sleep Mode Clock Gating Control
Bit 0 - SSI Module 0 Deep-Sleep Mode Clock Gating Control
Bit 1 - SSI Module 1 Deep-Sleep Mode Clock Gating Control
Bit 2 - SSI Module 2 Deep-Sleep Mode Clock Gating Control
Bit 3 - SSI Module 3 Deep-Sleep Mode Clock Gating Control
Bit 0 - I2C Module 0 Deep-Sleep Mode Clock Gating Control
Bit 1 - I2C Module 1 Deep-Sleep Mode Clock Gating Control
Bit 2 - I2C Module 2 Deep-Sleep Mode Clock Gating Control
Bit 3 - I2C Module 3 Deep-Sleep Mode Clock Gating Control
Bit 0 - USB Module Deep-Sleep Mode Clock Gating Control
Bit 0 - CAN Module 0 Deep-Sleep Mode Clock Gating Control
Bit 1 - CAN Module 1 Deep-Sleep Mode Clock Gating Control
Bit 0 - ADC Module 0 Deep-Sleep Mode Clock Gating Control
Bit 1 - ADC Module 1 Deep-Sleep Mode Clock Gating Control
Bit 0 - Analog Comparator Module 0 Deep-Sleep Mode Clock Gating Control
Bit 0 - PWM Module 0 Deep-Sleep Mode Clock Gating Control
Bit 1 - PWM Module 1 Deep-Sleep Mode Clock Gating Control
Bit 0 - QEI Module 0 Deep-Sleep Mode Clock Gating Control
Bit 1 - QEI Module 1 Deep-Sleep Mode Clock Gating Control
Bit 0 - EEPROM Module Deep-Sleep Mode Clock Gating Control
Bit 0 - 32/64-Bit Wide General-Purpose Timer 0 Deep-Sleep Mode Clock Gating Control
Bit 1 - 32/64-Bit Wide General-Purpose Timer 1 Deep-Sleep Mode Clock Gating Control
Bit 2 - 32/64-Bit Wide General-Purpose Timer 2 Deep-Sleep Mode Clock Gating Control
Bit 3 - 32/64-Bit Wide General-Purpose Timer 3 Deep-Sleep Mode Clock Gating Control
Bit 4 - 32/64-Bit Wide General-Purpose Timer 4 Deep-Sleep Mode Clock Gating Control
Bit 5 - 32/64-Bit Wide General-Purpose Timer 5 Deep-Sleep Mode Clock Gating Control
Bit 0 - Watchdog Timer 0 Peripheral Ready
Bit 1 - Watchdog Timer 1 Peripheral Ready
Bit 0 - 16/32-Bit General-Purpose Timer 0 Peripheral Ready
Bit 1 - 16/32-Bit General-Purpose Timer 1 Peripheral Ready
Bit 2 - 16/32-Bit General-Purpose Timer 2 Peripheral Ready
Bit 3 - 16/32-Bit General-Purpose Timer 3 Peripheral Ready
Bit 4 - 16/32-Bit General-Purpose Timer 4 Peripheral Ready
Bit 5 - 16/32-Bit General-Purpose Timer 5 Peripheral Ready
Bit 0 - GPIO Port A Peripheral Ready
Bit 1 - GPIO Port B Peripheral Ready
Bit 2 - GPIO Port C Peripheral Ready
Bit 3 - GPIO Port D Peripheral Ready
Bit 4 - GPIO Port E Peripheral Ready
Bit 5 - GPIO Port F Peripheral Ready
Bit 0 - uDMA Module Peripheral Ready
Bit 0 - Hibernation Module Peripheral Ready
Bit 0 - UART Module 0 Peripheral Ready
Bit 1 - UART Module 1 Peripheral Ready
Bit 2 - UART Module 2 Peripheral Ready
Bit 3 - UART Module 3 Peripheral Ready
Bit 4 - UART Module 4 Peripheral Ready
Bit 5 - UART Module 5 Peripheral Ready
Bit 6 - UART Module 6 Peripheral Ready
Bit 7 - UART Module 7 Peripheral Ready
Bit 0 - SSI Module 0 Peripheral Ready
Bit 1 - SSI Module 1 Peripheral Ready
Bit 2 - SSI Module 2 Peripheral Ready
Bit 3 - SSI Module 3 Peripheral Ready
Bit 0 - I2C Module 0 Peripheral Ready
Bit 1 - I2C Module 1 Peripheral Ready
Bit 2 - I2C Module 2 Peripheral Ready
Bit 3 - I2C Module 3 Peripheral Ready
Bit 0 - USB Module Peripheral Ready
Bit 0 - CAN Module 0 Peripheral Ready
Bit 1 - CAN Module 1 Peripheral Ready
Bit 0 - ADC Module 0 Peripheral Ready
Bit 1 - ADC Module 1 Peripheral Ready
Bit 0 - Analog Comparator Module 0 Peripheral Ready
Bit 0 - PWM Module 0 Peripheral Ready
Bit 1 - PWM Module 1 Peripheral Ready
Bit 0 - QEI Module 0 Peripheral Ready
Bit 1 - QEI Module 1 Peripheral Ready
Bit 0 - EEPROM Module Peripheral Ready
Bit 0 - 32/64-Bit Wide General-Purpose Timer 0 Peripheral Ready
Bit 1 - 32/64-Bit Wide General-Purpose Timer 1 Peripheral Ready
Bit 2 - 32/64-Bit Wide General-Purpose Timer 2 Peripheral Ready
Bit 3 - 32/64-Bit Wide General-Purpose Timer 3 Peripheral Ready
Bit 4 - 32/64-Bit Wide General-Purpose Timer 4 Peripheral Ready
Bit 5 - 32/64-Bit Wide General-Purpose Timer 5 Peripheral Ready
Get enumerated values variant
Checks if the value of the field is IDLE
Checks if the value of the field is RD_CTRL
Checks if the value of the field is RD_SRCENDP
Checks if the value of the field is RD_DSTENDP
Checks if the value of the field is RD_SRCDAT
Checks if the value of the field is WR_DSTDAT
Checks if the value of the field is WAIT
Checks if the value of the field is WR_CTRL
Checks if the value of the field is STALL
Checks if the value of the field is DONE
Checks if the value of the field is UNDEF
Bit 0 - Master Enable Status
Bits 4:7 - Control State Machine Status
Bits 16:20 - Available uDMA Channels Minus 1
Bits 10:31 - Channel Control Base Address
Bits 0:31 - Alternate Channel Address Pointer
Bits 0:31 - Channel [n]
Wait Status
Bits 0:31 - Channel [n]
Useburst Set
Bits 0:31 - Channel [n]
Request Mask Set
Bits 0:31 - Channel [n]
Enable Set
Bits 0:31 - Channel [n]
Alternate Set
Bits 0:31 - Channel [n]
Priority Set
Bit 0 - uDMA Bus Error Status
Get enumerated values variant
Checks if the value of the field is PRIMARY
Checks if the value of the field is SECONDARY
Bits 0:31 - Channel [n]
Assignment Select
Bits 0:3 - uDMA Channel 0 Source Select
Bits 4:7 - uDMA Channel 1 Source Select
Bits 8:11 - uDMA Channel 2 Source Select
Bits 12:15 - uDMA Channel 3 Source Select
Bits 16:19 - uDMA Channel 4 Source Select
Bits 20:23 - uDMA Channel 5 Source Select
Bits 24:27 - uDMA Channel 6 Source Select
Bits 28:31 - uDMA Channel 7 Source Select
Bits 0:3 - uDMA Channel 8 Source Select
Bits 4:7 - uDMA Channel 9 Source Select
Bits 8:11 - uDMA Channel 10 Source Select
Bits 12:15 - uDMA Channel 11 Source Select
Bits 16:19 - uDMA Channel 12 Source Select
Bits 20:23 - uDMA Channel 13 Source Select
Bits 24:27 - uDMA Channel 14 Source Select
Bits 28:31 - uDMA Channel 15 Source Select
Bits 0:3 - uDMA Channel 16 Source Select
Bits 4:7 - uDMA Channel 17 Source Select
Bits 8:11 - uDMA Channel 18 Source Select
Bits 12:15 - uDMA Channel 19 Source Select
Bits 16:19 - uDMA Channel 20 Source Select
Bits 20:23 - uDMA Channel 21 Source Select
Bits 24:27 - uDMA Channel 22 Source Select
Bits 28:31 - uDMA Channel 23 Source Select
Bits 0:3 - uDMA Channel 24 Source Select
Bits 4:7 - uDMA Channel 25 Source Select
Bits 8:11 - uDMA Channel 26 Source Select
Bits 12:15 - uDMA Channel 27 Source Select
Bits 16:19 - uDMA Channel 28 Source Select
Bits 20:23 - uDMA Channel 29 Source Select
Bits 24:27 - uDMA Channel 30 Source Select
Bits 28:31 - uDMA Channel 31 Source Select
This method tests for self
and other
values to be equal, and is used
by ==
.
This method tests for !=
. The default implementation is almost always
sufficient, and should not be overridden without very good reason.
Immutably borrows from an owned value.
Read more
Mutably borrows from an owned value.
Read more
Returns the argument unchanged.
Calls U::from(self)
.
That is, this conversion is whatever the implementation of
From<T> for U
chooses to do.
The type returned in the event of a conversion error.
Performs the conversion.
The type returned in the event of a conversion error.
Performs the conversion.