pub struct AirQualityBricklet { /* private fields */ }
Expand description
Measures IAQ index, temperature, humidity and air pressure
Implementations§
Source§impl AirQualityBricklet
impl AirQualityBricklet
pub const DEVICE_IDENTIFIER: u16 = 297u16
pub const DEVICE_DISPLAY_NAME: &'static str = "Air Quality Bricklet"
Sourcepub fn new(uid: Uid, connection: AsyncIpConnection) -> AirQualityBricklet
pub fn new(uid: Uid, connection: AsyncIpConnection) -> AirQualityBricklet
Creates an object with the unique device ID uid
. This object can then be used after the IP Connection ip_connection
is connected.
Sourcepub fn get_response_expected(
&mut self,
fun: AirQualityBrickletFunction,
) -> Result<bool, GetResponseExpectedError>
pub fn get_response_expected( &mut self, fun: AirQualityBrickletFunction, ) -> Result<bool, GetResponseExpectedError>
Returns the response expected flag for the function specified by the function ID parameter. It is true if the function is expected to send a response, false otherwise.
For getter functions this is enabled by default and cannot be disabled, because those
functions will always send a response. For callback configuration functions it is enabled
by default too, but can be disabled by set_response_expected
.
For setter functions it is disabled by default and can be enabled.
Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.
See set_response_expected
for the list of function ID constants available for this function.
Sourcepub fn set_response_expected(
&mut self,
fun: AirQualityBrickletFunction,
response_expected: bool,
) -> Result<(), SetResponseExpectedError>
pub fn set_response_expected( &mut self, fun: AirQualityBrickletFunction, response_expected: bool, ) -> Result<(), SetResponseExpectedError>
Changes the response expected flag of the function specified by the function ID parameter. This flag can only be changed for setter (default value: false) and callback configuration functions (default value: true). For getter functions it is always enabled.
Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.
Sourcepub fn set_response_expected_all(&mut self, response_expected: bool)
pub fn set_response_expected_all(&mut self, response_expected: bool)
Changes the response expected flag for all setter and callback configuration functions of this device at once.
Sourcepub fn get_api_version(&self) -> [u8; 3]
pub fn get_api_version(&self) -> [u8; 3]
Returns the version of the API definition (major, minor, revision) implemented by this API bindings. This is neither the release version of this API bindings nor does it tell you anything about the represented Brick or Bricklet.
Sourcepub async fn get_all_values_callback_receiver(
&mut self,
) -> impl Stream<Item = AllValuesEvent>
pub async fn get_all_values_callback_receiver( &mut self, ) -> impl Stream<Item = AllValuesEvent>
This receiver is triggered periodically according to the configuration set by
set_all_values_callback_configuration
.
The parameters are the same as get_all_values
.
Sourcepub async fn get_iaq_index_callback_receiver(
&mut self,
) -> impl Stream<Item = IaqIndexEvent>
pub async fn get_iaq_index_callback_receiver( &mut self, ) -> impl Stream<Item = IaqIndexEvent>
This receiver is triggered periodically according to the configuration set by
[set_iaq_index_callback_configuration
].
The parameters are the same as [get_iaq_index
].
Sourcepub async fn get_temperature_callback_receiver(
&mut self,
) -> impl Stream<Item = i32>
pub async fn get_temperature_callback_receiver( &mut self, ) -> impl Stream<Item = i32>
This receiver is triggered periodically according to the configuration set by
[set_temperature_callback_configuration
].
The parameter is the same as [get_temperature
].
Sourcepub async fn get_humidity_callback_receiver(
&mut self,
) -> impl Stream<Item = i32>
pub async fn get_humidity_callback_receiver( &mut self, ) -> impl Stream<Item = i32>
This receiver is triggered periodically according to the configuration set by
[set_humidity_callback_configuration
].
The parameter is the same as [get_humidity
].
Sourcepub async fn get_air_pressure_callback_receiver(
&mut self,
) -> impl Stream<Item = i32>
pub async fn get_air_pressure_callback_receiver( &mut self, ) -> impl Stream<Item = i32>
This receiver is triggered periodically according to the configuration set by
[set_air_pressure_callback_configuration
].
The parameter is the same as [get_air_pressure
].
Sourcepub async fn get_all_values(&mut self) -> Result<AllValues, TinkerforgeError>
pub async fn get_all_values(&mut self) -> Result<AllValues, TinkerforgeError>
Returns all values measured by the Air Quality Bricklet. The values are IAQ (Indoor Air Quality) Index (higher value means greater level of air pollution), IAQ Index Accuracy, Temperature, Humidity and Air Pressure.
.. image:: /Images/Misc/bricklet_air_quality_iaq_index.png :scale: 100 % :alt: Air Quality Index description :align: center :target: ../../_images/Misc/bricklet_air_quality_iaq_index.png
Associated constants:
- AIR_QUALITY_BRICKLET_ACCURACY_UNRELIABLE
- AIR_QUALITY_BRICKLET_ACCURACY_LOW
- AIR_QUALITY_BRICKLET_ACCURACY_MEDIUM
- AIR_QUALITY_BRICKLET_ACCURACY_HIGH
Sourcepub async fn set_temperature_offset(
&mut self,
offset: i32,
) -> Result<(), TinkerforgeError>
pub async fn set_temperature_offset( &mut self, offset: i32, ) -> Result<(), TinkerforgeError>
Sets a temperature offset. A offset of 10 will decrease the measured temperature by 0.1 °C.
If you install this Bricklet into an enclosure and you want to measure the ambient temperature, you may have to decrease the measured temperature by some value to compensate for the error because of the heating inside of the enclosure.
We recommend that you leave the parts in the enclosure running for at least 24 hours such that a temperature equilibrium can be reached. After that you can measure the temperature directly outside of enclosure and set the difference as offset.
This temperature offset is used to calculate the relative humidity and IAQ index measurements. In case the Bricklet is installed in an enclosure, we recommend to measure and set the temperature offset to improve the accuracy of the measurements.
Sourcepub async fn get_temperature_offset(&mut self) -> Result<i32, TinkerforgeError>
pub async fn get_temperature_offset(&mut self) -> Result<i32, TinkerforgeError>
Returns the temperature offset as set by
[set_temperature_offset
].
Sourcepub async fn set_all_values_callback_configuration(
&mut self,
period: u32,
value_has_to_change: bool,
) -> Result<(), TinkerforgeError>
pub async fn set_all_values_callback_configuration( &mut self, period: u32, value_has_to_change: bool, ) -> Result<(), TinkerforgeError>
The period is the period with which the [get_all_values_callback_receiver
]
receiver is triggered periodically. A value of 0 turns the receiver off.
If the value has to change
-parameter is set to true, the receiver is only
triggered after at least one of the values has changed. If the values didn’t
change within the period, the receiver is triggered immediately on change.
If it is set to false, the receiver is continuously triggered with the period, independent of the value.
Sourcepub async fn get_all_values_callback_configuration(
&mut self,
) -> Result<AllValuesCallbackConfiguration, TinkerforgeError>
pub async fn get_all_values_callback_configuration( &mut self, ) -> Result<AllValuesCallbackConfiguration, TinkerforgeError>
Returns the receiver configuration as set by
[set_all_values_callback_configuration
].
Sourcepub async fn get_iaq_index(&mut self) -> Result<IaqIndex, TinkerforgeError>
pub async fn get_iaq_index(&mut self) -> Result<IaqIndex, TinkerforgeError>
Returns the IAQ index and accuracy. The higher the IAQ index, the greater the level of air pollution.
.. image:: /Images/Misc/bricklet_air_quality_iaq_index.png :scale: 100 % :alt: IAQ index description :align: center :target: ../../_images/Misc/bricklet_air_quality_iaq_index.png
If you want to get the value periodically, it is recommended to use the
[get_iaq_index_callback_receiver
] receiver. You can set the receiver configuration
with [set_iaq_index_callback_configuration
].
Associated constants:
- AIR_QUALITY_BRICKLET_ACCURACY_UNRELIABLE
- AIR_QUALITY_BRICKLET_ACCURACY_LOW
- AIR_QUALITY_BRICKLET_ACCURACY_MEDIUM
- AIR_QUALITY_BRICKLET_ACCURACY_HIGH
Sourcepub async fn set_iaq_index_callback_configuration(
&mut self,
period: u32,
value_has_to_change: bool,
) -> Result<(), TinkerforgeError>
pub async fn set_iaq_index_callback_configuration( &mut self, period: u32, value_has_to_change: bool, ) -> Result<(), TinkerforgeError>
The period is the period with which the [get_iaq_index_callback_receiver
]
receiver is triggered periodically. A value of 0 turns the receiver off.
If the value has to change
-parameter is set to true, the receiver is only
triggered after at least one of the values has changed. If the values didn’t
change within the period, the receiver is triggered immediately on change.
If it is set to false, the receiver is continuously triggered with the period, independent of the value.
Sourcepub async fn get_iaq_index_callback_configuration(
&mut self,
) -> Result<IaqIndexCallbackConfiguration, TinkerforgeError>
pub async fn get_iaq_index_callback_configuration( &mut self, ) -> Result<IaqIndexCallbackConfiguration, TinkerforgeError>
Returns the receiver configuration as set by
[set_iaq_index_callback_configuration
].
Sourcepub async fn get_temperature(&mut self) -> Result<i32, TinkerforgeError>
pub async fn get_temperature(&mut self) -> Result<i32, TinkerforgeError>
Returns temperature.
If you want to get the value periodically, it is recommended to use the
[get_temperature_callback_receiver
] receiver. You can set the receiver configuration
with [set_temperature_callback_configuration
].
Sourcepub async fn set_temperature_callback_configuration(
&mut self,
period: u32,
value_has_to_change: bool,
option: char,
min: i32,
max: i32,
) -> Result<(), TinkerforgeError>
pub async fn set_temperature_callback_configuration( &mut self, period: u32, value_has_to_change: bool, option: char, min: i32, max: i32, ) -> Result<(), TinkerforgeError>
The period is the period with which the [get_temperature_callback_receiver
] receiver is triggered
periodically. A value of 0 turns the receiver off.
If the value has to change
-parameter is set to true, the receiver is only
triggered after the value has changed. If the value didn’t change
within the period, the receiver is triggered immediately on change.
If it is set to false, the receiver is continuously triggered with the period, independent of the value.
It is furthermore possible to constrain the receiver with thresholds.
The option
-parameter together with min/max sets a threshold for the [get_temperature_callback_receiver
] receiver.
The following options are possible:
Option | Description |
---|---|
‘x’ | Threshold is turned off |
‘o’ | Threshold is triggered when the value is outside the min and max values |
‘i’ | Threshold is triggered when the value is inside or equal to the min and max values |
‘<’ | Threshold is triggered when the value is smaller than the min value (max is ignored) |
‘>’ | Threshold is triggered when the value is greater than the min value (max is ignored) |
If the option is set to ‘x’ (threshold turned off) the receiver is triggered with the fixed period.
Associated constants:
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_OFF
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_OUTSIDE
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_INSIDE
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_SMALLER
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_GREATER
Sourcepub async fn get_temperature_callback_configuration(
&mut self,
) -> Result<TemperatureCallbackConfiguration, TinkerforgeError>
pub async fn get_temperature_callback_configuration( &mut self, ) -> Result<TemperatureCallbackConfiguration, TinkerforgeError>
Returns the receiver configuration as set by [set_temperature_callback_configuration
].
Associated constants:
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_OFF
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_OUTSIDE
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_INSIDE
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_SMALLER
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_GREATER
Sourcepub async fn get_humidity(&mut self) -> Result<i32, TinkerforgeError>
pub async fn get_humidity(&mut self) -> Result<i32, TinkerforgeError>
Returns relative humidity.
If you want to get the value periodically, it is recommended to use the
[get_humidity_callback_receiver
] receiver. You can set the receiver configuration
with [set_humidity_callback_configuration
].
Sourcepub async fn set_humidity_callback_configuration(
&mut self,
period: u32,
value_has_to_change: bool,
option: char,
min: i32,
max: i32,
) -> Result<(), TinkerforgeError>
pub async fn set_humidity_callback_configuration( &mut self, period: u32, value_has_to_change: bool, option: char, min: i32, max: i32, ) -> Result<(), TinkerforgeError>
The period is the period with which the [get_humidity_callback_receiver
] receiver is triggered
periodically. A value of 0 turns the receiver off.
If the value has to change
-parameter is set to true, the receiver is only
triggered after the value has changed. If the value didn’t change
within the period, the receiver is triggered immediately on change.
If it is set to false, the receiver is continuously triggered with the period, independent of the value.
It is furthermore possible to constrain the receiver with thresholds.
The option
-parameter together with min/max sets a threshold for the [get_humidity_callback_receiver
] receiver.
The following options are possible:
Option | Description |
---|---|
‘x’ | Threshold is turned off |
‘o’ | Threshold is triggered when the value is outside the min and max values |
‘i’ | Threshold is triggered when the value is inside or equal to the min and max values |
‘<’ | Threshold is triggered when the value is smaller than the min value (max is ignored) |
‘>’ | Threshold is triggered when the value is greater than the min value (max is ignored) |
If the option is set to ‘x’ (threshold turned off) the receiver is triggered with the fixed period.
Associated constants:
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_OFF
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_OUTSIDE
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_INSIDE
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_SMALLER
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_GREATER
Sourcepub async fn get_humidity_callback_configuration(
&mut self,
) -> Result<HumidityCallbackConfiguration, TinkerforgeError>
pub async fn get_humidity_callback_configuration( &mut self, ) -> Result<HumidityCallbackConfiguration, TinkerforgeError>
Returns the receiver configuration as set by [set_humidity_callback_configuration
].
Associated constants:
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_OFF
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_OUTSIDE
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_INSIDE
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_SMALLER
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_GREATER
Sourcepub async fn get_air_pressure(&mut self) -> Result<i32, TinkerforgeError>
pub async fn get_air_pressure(&mut self) -> Result<i32, TinkerforgeError>
Returns air pressure.
If you want to get the value periodically, it is recommended to use the
[get_air_pressure_callback_receiver
] receiver. You can set the receiver configuration
with [set_air_pressure_callback_configuration
].
Sourcepub async fn set_air_pressure_callback_configuration(
&mut self,
period: u32,
value_has_to_change: bool,
option: char,
min: i32,
max: i32,
) -> Result<(), TinkerforgeError>
pub async fn set_air_pressure_callback_configuration( &mut self, period: u32, value_has_to_change: bool, option: char, min: i32, max: i32, ) -> Result<(), TinkerforgeError>
The period is the period with which the [get_air_pressure_callback_receiver
] receiver is triggered
periodically. A value of 0 turns the receiver off.
If the value has to change
-parameter is set to true, the receiver is only
triggered after the value has changed. If the value didn’t change
within the period, the receiver is triggered immediately on change.
If it is set to false, the receiver is continuously triggered with the period, independent of the value.
It is furthermore possible to constrain the receiver with thresholds.
The option
-parameter together with min/max sets a threshold for the [get_air_pressure_callback_receiver
] receiver.
The following options are possible:
Option | Description |
---|---|
‘x’ | Threshold is turned off |
‘o’ | Threshold is triggered when the value is outside the min and max values |
‘i’ | Threshold is triggered when the value is inside or equal to the min and max values |
‘<’ | Threshold is triggered when the value is smaller than the min value (max is ignored) |
‘>’ | Threshold is triggered when the value is greater than the min value (max is ignored) |
If the option is set to ‘x’ (threshold turned off) the receiver is triggered with the fixed period.
Associated constants:
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_OFF
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_OUTSIDE
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_INSIDE
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_SMALLER
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_GREATER
Sourcepub async fn get_air_pressure_callback_configuration(
&mut self,
) -> Result<AirPressureCallbackConfiguration, TinkerforgeError>
pub async fn get_air_pressure_callback_configuration( &mut self, ) -> Result<AirPressureCallbackConfiguration, TinkerforgeError>
Returns the receiver configuration as set by [set_air_pressure_callback_configuration
].
Associated constants:
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_OFF
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_OUTSIDE
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_INSIDE
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_SMALLER
- AIR_QUALITY_BRICKLET_THRESHOLD_OPTION_GREATER
Sourcepub async fn remove_calibration(&mut self) -> Result<(), TinkerforgeError>
pub async fn remove_calibration(&mut self) -> Result<(), TinkerforgeError>
Deletes the calibration from flash. After you call this function, you need to power cycle the Air Quality Bricklet.
On the next power up the Bricklet will start a new calibration, as if it was started for the very first time.
The calibration is based on the data of the last four days, so it takes four days until a full calibration is re-established.
.. versionadded:: 2.0.3$nbsp;(Plugin)
Sourcepub async fn set_background_calibration_duration(
&mut self,
duration: u8,
) -> Result<(), TinkerforgeError>
pub async fn set_background_calibration_duration( &mut self, duration: u8, ) -> Result<(), TinkerforgeError>
The Air Quality Bricklet uses an automatic background calibration mechanism to calculate the IAQ Index. This calibration mechanism considers a history of measured data. The duration of this history can be configured to either be 4 days or 28 days.
If you keep the Bricklet mostly at one place and it does not get moved around to different environments, we recommend that you use a duration of 28 days.
If you change the duration, the current calibration will be discarded and the calibration will start from beginning again. The configuration of the duration is saved in flash, so you should only have to call this function once in the lifetime of the Bricklet.
The Bricklet has to be power cycled after this function is called for a duration change to take effect.
Before firmware version 2.0.3 this was not configurable and the duration was 4 days.
The default value (since firmware version 2.0.3) is 28 days.
.. versionadded:: 2.0.3$nbsp;(Plugin)
Associated constants:
- AIR_QUALITY_BRICKLET_DURATION_4_DAYS
- AIR_QUALITY_BRICKLET_DURATION_28_DAYS
Sourcepub async fn get_background_calibration_duration(
&mut self,
) -> Result<u8, TinkerforgeError>
pub async fn get_background_calibration_duration( &mut self, ) -> Result<u8, TinkerforgeError>
Returns the background calibration duration as set by
[set_background_calibration_duration
].
.. versionadded:: 2.0.3$nbsp;(Plugin)
Associated constants:
- AIR_QUALITY_BRICKLET_DURATION_4_DAYS
- AIR_QUALITY_BRICKLET_DURATION_28_DAYS
Sourcepub async fn get_spitfp_error_count(
&mut self,
) -> Result<SpitfpErrorCount, TinkerforgeError>
pub async fn get_spitfp_error_count( &mut self, ) -> Result<SpitfpErrorCount, TinkerforgeError>
Returns the error count for the communication between Brick and Bricklet.
The errors are divided into
- ACK checksum errors,
- message checksum errors,
- framing errors and
- overflow errors.
The errors counts are for errors that occur on the Bricklet side. All Bricks have a similar function that returns the errors on the Brick side.
Sourcepub async fn set_bootloader_mode(
&mut self,
mode: u8,
) -> Result<u8, TinkerforgeError>
pub async fn set_bootloader_mode( &mut self, mode: u8, ) -> Result<u8, TinkerforgeError>
Sets the bootloader mode and returns the status after the requested mode change was instigated.
You can change from bootloader mode to firmware mode and vice versa. A change from bootloader mode to firmware mode will only take place if the entry function, device identifier and CRC are present and correct.
This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.
Associated constants:
- AIR_QUALITY_BRICKLET_BOOTLOADER_MODE_BOOTLOADER
- AIR_QUALITY_BRICKLET_BOOTLOADER_MODE_FIRMWARE
- AIR_QUALITY_BRICKLET_BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT
- AIR_QUALITY_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT
- AIR_QUALITY_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT
- AIR_QUALITY_BRICKLET_BOOTLOADER_STATUS_OK
- AIR_QUALITY_BRICKLET_BOOTLOADER_STATUS_INVALID_MODE
- AIR_QUALITY_BRICKLET_BOOTLOADER_STATUS_NO_CHANGE
- AIR_QUALITY_BRICKLET_BOOTLOADER_STATUS_ENTRY_FUNCTION_NOT_PRESENT
- AIR_QUALITY_BRICKLET_BOOTLOADER_STATUS_DEVICE_IDENTIFIER_INCORRECT
- AIR_QUALITY_BRICKLET_BOOTLOADER_STATUS_CRC_MISMATCH
Sourcepub async fn get_bootloader_mode(&mut self) -> Result<u8, TinkerforgeError>
pub async fn get_bootloader_mode(&mut self) -> Result<u8, TinkerforgeError>
Returns the current bootloader mode, see [set_bootloader_mode
].
Associated constants:
- AIR_QUALITY_BRICKLET_BOOTLOADER_MODE_BOOTLOADER
- AIR_QUALITY_BRICKLET_BOOTLOADER_MODE_FIRMWARE
- AIR_QUALITY_BRICKLET_BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT
- AIR_QUALITY_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT
- AIR_QUALITY_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT
Sourcepub async fn set_write_firmware_pointer(
&mut self,
pointer: u32,
) -> Result<(), TinkerforgeError>
pub async fn set_write_firmware_pointer( &mut self, pointer: u32, ) -> Result<(), TinkerforgeError>
Sets the firmware pointer for [write_firmware
]. The pointer has
to be increased by chunks of size 64. The data is written to flash
every 4 chunks (which equals to one page of size 256).
This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.
Sourcepub async fn write_firmware(
&mut self,
data: &[u8; 64],
) -> Result<u8, TinkerforgeError>
pub async fn write_firmware( &mut self, data: &[u8; 64], ) -> Result<u8, TinkerforgeError>
Writes 64 Bytes of firmware at the position as written by
[set_write_firmware_pointer
] before. The firmware is written
to flash every 4 chunks.
You can only write firmware in bootloader mode.
This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.
Sourcepub async fn set_status_led_config(
&mut self,
config: u8,
) -> Result<(), TinkerforgeError>
pub async fn set_status_led_config( &mut self, config: u8, ) -> Result<(), TinkerforgeError>
Sets the status LED configuration. By default the LED shows communication traffic between Brick and Bricklet, it flickers once for every 10 received data packets.
You can also turn the LED permanently on/off or show a heartbeat.
If the Bricklet is in bootloader mode, the LED is will show heartbeat by default.
Associated constants:
- AIR_QUALITY_BRICKLET_STATUS_LED_CONFIG_OFF
- AIR_QUALITY_BRICKLET_STATUS_LED_CONFIG_ON
- AIR_QUALITY_BRICKLET_STATUS_LED_CONFIG_SHOW_HEARTBEAT
- AIR_QUALITY_BRICKLET_STATUS_LED_CONFIG_SHOW_STATUS
Sourcepub async fn get_status_led_config(&mut self) -> Result<u8, TinkerforgeError>
pub async fn get_status_led_config(&mut self) -> Result<u8, TinkerforgeError>
Returns the configuration as set by [set_status_led_config
]
Associated constants:
- AIR_QUALITY_BRICKLET_STATUS_LED_CONFIG_OFF
- AIR_QUALITY_BRICKLET_STATUS_LED_CONFIG_ON
- AIR_QUALITY_BRICKLET_STATUS_LED_CONFIG_SHOW_HEARTBEAT
- AIR_QUALITY_BRICKLET_STATUS_LED_CONFIG_SHOW_STATUS
Sourcepub async fn get_chip_temperature(&mut self) -> Result<i16, TinkerforgeError>
pub async fn get_chip_temperature(&mut self) -> Result<i16, TinkerforgeError>
Returns the temperature as measured inside the microcontroller. The value returned is not the ambient temperature!
The temperature is only proportional to the real temperature and it has bad accuracy. Practically it is only useful as an indicator for temperature changes.
Sourcepub async fn reset(&mut self) -> Result<(), TinkerforgeError>
pub async fn reset(&mut self) -> Result<(), TinkerforgeError>
Calling this function will reset the Bricklet. All configurations will be lost.
After a reset you have to create new device objects, calling functions on the existing ones will result in undefined behavior!
Sourcepub async fn write_uid(&mut self, uid: u32) -> Result<(), TinkerforgeError>
pub async fn write_uid(&mut self, uid: u32) -> Result<(), TinkerforgeError>
Writes a new UID into flash. If you want to set a new UID you have to decode the Base58 encoded UID string into an integer first.
We recommend that you use Brick Viewer to change the UID.
Sourcepub async fn read_uid(&mut self) -> Result<u32, TinkerforgeError>
pub async fn read_uid(&mut self) -> Result<u32, TinkerforgeError>
Returns the current UID as an integer. Encode as Base58 to get the usual string version.
Sourcepub async fn get_identity(&mut self) -> Result<Identity, TinkerforgeError>
pub async fn get_identity(&mut self) -> Result<Identity, TinkerforgeError>
Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.
The position can be ‘a’, ‘b’, ‘c’, ‘d’, ‘e’, ‘f’, ‘g’ or ‘h’ (Bricklet Port). A Bricklet connected to an Isolator Bricklet is always at position ‘z’.
The device identifier numbers can be found here. |device_identifier_constant|