pub struct FMC_PATT_SPEC;
Expand description

The FMC_PATT read/write register contains NAND Flash memory bank timing information. It is used for 8-bit accesses to the NAND Flash attribute memory space during the last address write access when the timing differs from previous accesses (for Ready/Busy management, refer to Section25.8.5: NAND Flash prewait function).

This register you can read, write_with_zero, reset, write, modify. See API.

For information about available fields see fmc_patt module

Trait Implementations

read() method returns fmc_patt::R reader structure

Result from a call to read and argument to modify.

Raw register type (u8, u16, u32, …).

reset() method sets FMC_PATT to value 0x0a0a_0a0a

Reset value of the register.

write(|w| ..) method takes fmc_patt::W writer structure

Writer type argument to write, et al.

Auto Trait Implementations

Blanket Implementations

Gets the TypeId of self. Read more

Immutably borrows from an owned value. Read more

Mutably borrows from an owned value. Read more

Returns the argument unchanged.

Calls U::from(self).

That is, this conversion is whatever the implementation of From<T> for U chooses to do.

The type returned in the event of a conversion error.

Performs the conversion.

The type returned in the event of a conversion error.

Performs the conversion.