pub enum VariableName {
Show 329 variants ACCurrent, ACPhaseSwitchingSupported, ACVoltage, Active, ActiveMonitoringBase, ActiveMonitoringLevel, ActiveNetworkProfile, ActiveTransactionId, AdditionalInfoItemsPerMessage, AdditionalRootCertificateCheck, AllowEnergyTransferResumption, AllowNewSessionsPendingFirmwareUpdate, AllowReset, AllowSecurityProfileDowngrade, Angle, Attempts, AuthorizeRemoteStart, AvailabilityState, Available, BasicAuthPassword, BytesPerMessage, CentralContractValidationAllowed, CertSigningRepeatTimes, CertSigningWaitMinimum, Certificate, CertificateEntries, CertificateStatusSource, ChargeProtocol, ChargingCompleteBulk, ChargingCompleteFull, ChargingProfilePersistence, ChargingState, ChargingTime, Color, CommunicationParent, Complete, ConditionsSupported, ConfigurationValueSize, ConnectedTime, ConnectorType, ContractCertificateInstallationEnabled, ContractValidationOffline, Count, CountryName, Currency, CurrentImbalance, CustomImplementationEnabled, CustomTriggers, DCCurrent, DCInputPhaseControl, DCVoltage, DataText, DateTime, DepartureTime, DisablePostAuthorize, DisableRemoteAuthorization, DischargePower, DisplayMessages, ECVariant, EVConnectionTimeOut, ElectricalParent, Enabled, Energy, EnergyCapacity, EnergyExport, EnergyExportRegister, EnergyImport, EnergyImportRegister, Entries, ExternalConfigChangeDate, ExternalConstraintsProfileDisallowed, ExternalControlSignalsEnabled, Fallback, FanSpeed, FieldLength, FileTransferProtocols, FirmwareVersion, Force, Formats, Frequency, FrequencySchedule, FuseRating, HandleFailedTariff, HeartbeatInterval, Height, Humidity, Hysteresis, ICCID, IMSI, ISO15118EvseId, IdToken, Identity, Impedance, Interval, ItemsPerMessage, Label, Language, Length, LifeTime, Light, LimitChangeSignificance, LocalAuthorizeOffline, LocalFrequencyUpdateThreshold, LocalLoadBalancing, LocalPreAuthorize, LogicalParent, Manufacturer, MasterPassGroupId, MaxCertificateChainSize, MaxElements, MaxEnergyOnInvalidId, MaxExternalConstraintsId, MaxPeriodicEventStreams, MaxPriceElements, MaxSoc, Measurands, Message, MessageAttemptInterval, MessageAttempts, MessageTimeout, MinimumStatusDuration, Mode, Model, NetworkAddress, NetworkConfigurationPriority, NetworkProfileConnectionAttempts, NextTimeOffsetTransitionDateTime, NonEvseSpecific, NotificationMaxDelay, NotifyChargingLimitWithSchedules, NtpServerUri, NtpSource, OfflineQueuingSeverity, OfflineTariffFallbackMessage, OfflineThreshold, OfflineTxForUnknownIdEnabled, Operated, OperatingTimes, OrganizationName, Overload, Percent, PeriodsPerSchedule, PhaseRotation, Phases3to1, PhysicalParent, PnCEnabled, Policy, PostChargingTime, Power, Present, Problem, ProfileStackLevel, Protecting, ProtocolAgreed, ProtocolSupported, ProtocolSupportedByEV, PublicKey, PublicKeyWithSignedMeterValue, QueueAllMessages, RateUnit, RegisterValuesWithoutPhases, RemainingTimeBulk, RemainingTimeFull, ReportingValueSize, RequestMeteringReceipt, ResetRetries, ResumptionTimeout, SampledMeasurands, SamplingInterval, SeccId, SecurityProfile, SendDuringIdle, SerialNumber, ServiceRenegotiationSupport, SetpointPriority, SignReadings, SignStartedReadings, SignUpdatedReadings, SignalStrength, SlotStatus, SoC, SoH, State, StateOfCharge, StateOfChargeBulk, StopTxOnEVSideDisconnect, StopTxOnInvalidId, Storage, SupplyPhases, SupportedAdditionalPurposes, SupportedEnergyTransferModes, SupportedFormats, SupportedIdTokenTypes, SupportedLimits, SupportedOperationModes, SupportedPriorities, SupportedProviders, SupportedStates, SupportsDynamicProfiles, SupportsEvseSleep, SupportsExpiryDateTime, SupportsLimitAtSoC, SupportsMaxOfflineDuration, SupportsRandomizedDelay, SupportsUseLocalTime, Suspending, Suspension, TargetSoc, TariffFallbackMessage, Temperature, Time, TimeAdjustmentReportingThreshold, TimeOffset, TimeSource, TimeZone, Timeout, Token, TokenType, TotalCostFallbackMessage, Tries, Tripped, TxBeforeAcceptedEnabled, TxEndedInterval, TxEndedMeasurands, TxStartPoint, TxStartedMeasurands, TxStopPoint, TxUpdatedInterval, TxUpdatedMeasurands, UnlockOnEVSideDisconnect, UpstreamInterval, UpstreamMeasurands, V2GCertificateInstallationEnabled, VehicleCertificate, VehicleId, VersionDate, VersionNumber, VoltageImbalance, WorkingMode, VendorName, SupportedIdTokenType, SelftestActive, CHAdeMOProtocolNumber, VehicleStatus, DynamicControl, HighCurrentControl, HighVoltageControl, AutoManufacturerCode, VehicleID, BatteryCapacity, ValueSize, EvseId, MaxScheduleEntries, RequestedEnergyTransferMode, NotificationDelay, Capacity, MonitoringBase, MonitoringLevel, RetryBackOffRandomRange, RetryBackOffRepeatTimes, RetryBackOffWaitMinimum, WebSocketPingInterval, EnergyTransferResumptionRandomRange, MaxW, OverExcitedW, OverExcitedPF, UnderExcitedW, UnderExcitedPF, MaxVA, MaxVar, MaxVarNeg, MaxChargeRateW, MaxChargeRateVA, VNom, MaxV, MinV, ModesSupported, InverterManufacturer, InverterModel, InverterSerialNumber, InverterSwVersion, InverterHwVersion, IslandingDetectionMethod, IslandingDetectionTripTime, ReactiveSusceptance, TargetSoC, OcppCsmsUrl, OcppInterface, OcppTransport, OcppVersion, CsmsRootCertificateHashAlgorithm, CsmsRootCertificateIssuerKeyHash, CsmsRootCertificateIssuerNameHash, CsmsRootCertificateSerialNumber, VpnEnabled, VpnType, VpnServer, VpnUser, VpnGroup, VpnPassword, VpnKey, ApnEnabled, Apn, ApnUserName, ApnPassword, SimPin, PreferredNetwork, UseOnlyPreferredNetwork, ApnAuthentication, AuthorizeDirectPayment, AuthorizationAmount, IncrementalAuthorizationAmount, IncrementalAuthorizationThreshold, PaymentDetails, SettlementByCSMS, ReceiptServerUrl, ReceiptByCSMS, Merchant, TerminalID, PaymentServiceProvider, Connected, URLTemplate, URLParameters, TOTPVersion, ChargingStationId, ValidityTime, SharedSecret, QRCodeQuality, Other(String<50usize>),
}
Expand description

Standardized Variable.name values.

The schema types Variable.name as a plain string, since a Charging Station may expose vendor-specific variables alongside these.

An open set: values the specification doesn’t define are carried in Self::Other rather than rejected, so a deployment’s own values survive a deserialize/serialize round trip.

Comparison and hashing go through the wire string, not the variant, so Other("...") holding a standardized value compares equal to that variant.

Variants§

§

ACCurrent

RMS AC Current (in amperes). For 3-phase circuits, each phase (and optional neutral) is represented by a Variable instance equal to a value of the PhaseEnumType (e.g. L1,N). Unkeyed values reported for a Component declared to be multi-phase are assumed to be an average of all per-phase readings and written values are common per-phase settings. Example(s): ChargingStation: Total AC current consumption (all EVSE’s, ancillaries), EVSE: Total current consumed by EVSE: includes losses (AC->DC) and EVSE specific ancillaries (e.g. fans), ElectricalFeed: Inflow AC current on feed

§

ACPhaseSwitchingSupported

If defined and true, this EVSE supports the selection of which phase to use for 1 phase AC charging.

§

ACVoltage

RMS AC Voltage (in volts). For 3-phase circuits, each phase (and optional neutral) is represented by a Variable instance equal to a value of the PhaseEnumType (e.g. L1,N). Unkeyed values reported for a Component declared to be multi-phase are assumed to be an average ofall per-phase readings and written values are common per-phase settings. Example(s): ElectricalFeed: Input Voltage

§

Active

Component is in its non-resting / active state: e.g: On, Engaged, Locked. Some Components may have secondary functions that have corresponding Active Variables with an explicit Variable instance., Note: Monitoring of changes in the Active state of any Component can be specified by setting Delta monitoring on the boolean value with a delta values of 1. Setting/clearing an Active Variable activates/stops the associated functionality, where remotely controllable. Only components that are Available and Enabled can be in the Active state.

§

ActiveMonitoringBase

Shows the currently used MonitoringBase.

§

ActiveMonitoringLevel

Shows the currently use MonitoringLevel.

§

ActiveNetworkProfile

Indicates the configuration profile the station uses to connect to the network.

§

ActiveTransactionId

Active transaction on charging station or EVSE.

§

AdditionalInfoItemsPerMessage

Maximum number of additionalInfo items that can be sent in one message.

§

AdditionalRootCertificateCheck

When set to true, only one certificate (plus a temporarily fallback certificate) of certificateType CSMSRootCertificate is allowed to be installed at a time.

§

AllowEnergyTransferResumption

This variable defines whether energy transfer is allowed to be resumed when the transaction is resumed after a reset or power outage.

§

AllowNewSessionsPendingFirmwareUpdate

Indicates whether new sessions can be started on EVSEs, while Charging Station is waiting for all EVSEs to become Available in order to start a pending firmware update.

§

AllowReset

Component can be reset. Can be used to announce that an EVSE can be reset individually.

§

AllowSecurityProfileDowngrade

If this variable is implemented and set to true, then the Charging Station allows downgrading the security profile from 3 to 2.

§

Angle

Angle(s) relative to normal/design idle position. Multiple Variable instance values may be used to indicate angular position in multiple axes (e.g. Left-Right, Forward-Back).

§

Attempts

Number of attempts (INCLUDING the original attempt) in the last successful or attempted, cycle of operation. Applies typically to self-monitoring motorized electro-mechanical equipment, etc. {Null}: Unknown, 0: Not Attempted/Not allowed, 1: Single attempt/No retries [allowed], 2-N: [up to] N tries [allowed]

§

AuthorizeRemoteStart

Whether a remote request to start a transaction in the form of RequestStartTransactionRequest message should be authorized beforehand like a local action to start a transaction.

§

AvailabilityState

A value of ConnectorStatusEnumType (See part 2): replicates ConnectorStatus values reported in StatusNotification messages.

§

Available

The Component exists and is locally configured/wired for use, but might not be (remotely) Enabled.

§

BasicAuthPassword

The basic authentication password is used for HTTP Basic Authentication.

§

BytesPerMessage

Message Size (in bytes) - puts constraint on GetReportRequest, GetMonitoringReportRequest or GetVariableRequest message size.

§

CentralContractValidationAllowed

If this variable exists and has the value true, then Charging Station can provide a contract certificate that it cannot validate, to the CSMS for validation as part of the AuthorizeRequest.

§

CertSigningRepeatTimes

This variable can be used to configure the amount of times the Charging Station SHALL double the previous back-off time, starting with the number of seconds configured at CertSigningWaitMinimum, every time the back-off time expires without having received the CertificateSignedRequest containing the from the CSR generated signed certificate.

§

CertSigningWaitMinimum

This configuration variable defines how long the Charging Station has to wait before generating another CSR, in the case the CSMS accepts the SignCertificateRequest, but never returns the signed certificate.

§

Certificate

Digital Certificate (in Base64 encoding)

§

CertificateEntries

Amount of Certificates currently installed on the Charging Station.

§

CertificateStatusSource

When present, this variable tells CSMS whether Charging Station uses OCSP or CRL to check for revoked certificates.

§

ChargeProtocol

The Charging Control Protocol applicable to a Connector. CHAdeMO: CHAdeMO protocol, ISO15118: ISO15118 V2G protocol (wired or wireless) as used with CCS, CPPWM: IEC61851-1 / SAE J1772 protocol (ELV DC & PWM signalling via Control Pilot wire), Uncontrolled: No charging power management applies (e.g. Schuko socket), Undetermined: Yet to be determined (e.g. before plugged in), Unknown: Not determinable, NOTE: ChargeProtocol is distinct from and orthogonal to connectorType.

§

ChargingCompleteBulk

Charging up to StateOfChargeBulk has completed.

§

ChargingCompleteFull

Charging up to StateOfCharge.maxSet has completed.

§

ChargingProfilePersistence

If an instance of this variable is true, then charging profiles with the chargingProfilePurpose mentioned in the variableInstance are persistent, i.e. they are stored persistently and will still exist after a reboot.

§

ChargingState

This variable reports the current transaction charging state for an EVSE.

§

ChargingTime

Time from earliest to latest substantive energy transfer

§

Color

Standard 24 bit hexadecimal RGB values. Reg Green Blue color intensity, expressed as standard 24 bit hexadecimal RGB values: 3 00-FF (0-255), in order RRGGBB). E.g. 000000: Black, FF0000: Red, 00FF00: Green, 0000FF: Blue, FFFF00:Yellow, FFFFFF: White, 008000: Medium intensity green.

§

CommunicationParent

Points to a communication parent component (data flow source), to allow rendering the communication hierarchy in a UI.

§

Complete

Component’s operation cycle has completed. Used only in event notifications, where it is always true.

§

ConditionsSupported

If set to true the Charging Station supports tariffs with conditions.

§

ConfigurationValueSize

This Configuration Variable can be used to limit the following fields: SetVariableData.attributeValue and VariableCharacteristics.valuesList.

§

ConnectedTime

Time since logical connection established

§

ConnectorType

A value of ConnectorStringEnumType (See Appendix 7). Specific type of connector, including sub-variant information. Note: Distinct and orthogonal to Charging Protocol, Power Type, Phases.

§

ContractCertificateInstallationEnabled

If this variable is true, then ISO 15118 contract certificate installation/update as described by use case M01 - Certificate installation EV

§

ContractValidationOffline

If this variable is true, then Charging Station will try to validate a contract certificate when it is offline.

§

Count

General purpose integer count variable for Component state reporting

§

CountryName

The countryName of the SECC in the ISO 3166-1 format.

§

Currency

Currency in a ISO 4217 formatted currency code.

§

CurrentImbalance

Percentage current imbalance in an AC three phase supply.

§

CustomImplementationEnabled

This standard configuration variable is used to enable/disable the custom implementation named in the variableInstance.

§

CustomTriggers

This variable defines the names of custom triggers that Charging Station supports in a customTrigger field of TriggerMessageRequest.

§

DCCurrent

DC Current (in amperes). May be an instantaneous measurement, or a period average, depending on context/equipment.

§

DCInputPhaseControl

When DCInputPhaseControl is true, then the values of numberPhases and PhaseToUse in a ChargingSchedulePeriodType will select the input phases from the grid to be used by the DC EVSE.

§

DCVoltage

DC Voltage (volts). May be an instantaneous measurement, or a period average, depending on context/equipment.

§

DataText

Text associated with a Component, e.g. a Display.

§

DateTime

Point in time value, in [RFC3339] datetime format. Time zone optional.

§

DepartureTime

Time in [RFC3339] datetime format, when an EV intends to leave the charging station.

§

DisablePostAuthorize

When set to true this variable disables the behavior to request authorization for an

§

DisableRemoteAuthorization

When set to true this instructs the Charging Station to not issue any AuthorizationRequests, but only use Authorization Cache and Local Authorization List to determine validity of idTokens.

§

DischargePower

The variableCharacteristic maxLimit holds the maximum rated discharge power that this EVSE can provide. The variableCharacteristic maxSet holds the maximum configured discharge power that this EVSE can provide. The Actual value of the instantaneous (real) discharge power is recommended to be supported, but not required. Discharge power is represented by a positive value.

§

DisplayMessages

Maximum number of different messages that can configured in this Charging Station simultaneous, via SetDisplayMessageRequest.

§

ECVariant

Production series variants reflecting internal design changes or sub-component substitutions not affecting external functionality.

§

EVConnectionTimeOut

Interval from between ‘starting’ of a transaction until incipient transaction is automatically canceled, due to failure of EV driver to (correctly) insert the charging cable connector(s) into the appropriate socket(s).

§

ElectricalParent

Points to a electrical parent component (energy flow source), to allow rendering the electrical hierarchy in a UI.

§

Enabled

The Component is Enabled for operation. For Available components that cannot be selectively (remotely) enabled / disabled, this value is always true. Note: Available cannot be false of Enabled is true, so during inventory reporting, Enabled=1 also logically states Available=true

§

Energy

Energy quantity (in Wh) for reporting/configuring values related to stored energy (i.e. not transferred energy).

§

EnergyCapacity

Energy capacity in Wh of an energy storage device.

§

EnergyExport

Total energy transferred: e.g. from EV during (ongoing or terminated) charging session (in wH by default)

§

EnergyExportRegister

Cumulative export kWh register value, such as from a (certified) fiscal energy meter.

§

EnergyImport

Total energy transferred.

§

EnergyImportRegister

Cumulative export kWh register value, such as from a (certified) fiscal energy meter.

§

Entries

General purpose variable for reporting/managing numbers of entries in repetitive data structures. maxLimit characteristic reports maximum possible entries.

§

ExternalConfigChangeDate

Date/time when the configuration was changed externally, i.e. outside of CSMS, for example by a local service action.

§

ExternalConstraintsProfileDisallowed

Indicates whether a Charging Station allows an external system to submit a ChargingStationExternalConstraints charging profile.

§

ExternalControlSignalsEnabled

Indicates whether a Charging Station is able to respond to external control signals that influence charging. If the variable is true, but CSMS has set <<configkey-external-constraints-profile-disallowed>> = true, then external control signals are only allowed during a charging profile with a chargingProfilePeriod = ExternalLimits or ExternalSetpoint.

§

Fallback

Component is operating in a fallback, or backup mode. In inventory reports, a Value of 1 for the maxLimit characteristic indicates that the component can enter a fallback state (i.e. a fallback mode is present).

§

FanSpeed

Fan Speed (in RPM). A value of 0 represents stopped/stalled. An empty value indicates that fan speed cannot be read.

§

FieldLength

This variable is used to report the length of <field> in <message> when it is larger

§

FileTransferProtocols

List of supported file transfer protocols.

§

FirmwareVersion

Version number of firmware.

§

Force

Reports (impact) force/ acceleration values (estimates) in one or more directions, in units of Newtons or “g”. Multiple force readings in different (orthogonal) dimensions may be reported using Variable instance values, such as Down, Right, Forward.

§

Formats

List of message formats supported by this Charging Station. Possible values: ASCII, HTML, URI, UTF-8.

§

Frequency

Frequency of AC power, signal, or component operation.

§

FrequencySchedule

A JSON-formatted string with an array of { time, freq } pairs, in which time is

§

FuseRating

Current rating of a fuse/breaker. Variable instances keyed by phase identifier (L1/L2/L3/N).

§

HandleFailedTariff

This configuration determines how to act when a driver-specific tariff is received, which cannot be processed.

§

HeartbeatInterval

Interval of inactivity (no OCPP exchanges) with CSMS after which the Charging Station should send HeartbeatRequest.

§

Height

Height above(+)/below(-) reference level (ground level unless context demands otherwise).

§

Humidity

The relative humidity in %.

§

Hysteresis

Specifies the width of a ‘dead band’ (as a percentage of the threshold) around the central value of a threshold setting (e.g. MinSet, MaxSet, monitor thresholds) to avoid repeated triggering when the measured quantity lies close to the threshold and is subject to small variations.

§

ICCID

ICCID (Integrated Circuit Card IDentifier) of mobile data SIM card.

§

IMSI

IMSI (International Mobile Subscriber Identity) number of mobile data SIM card

§

ISO15118EvseId

EVSE ID in string format as used in ISO 15118 and IEC 63119-2

§

IdToken

The IdToken used to authorize a charging transaction.

§

Identity

The Charging Station identity.

§

Impedance

Impedance: Primary value is real (resistive only) impedance. Where a complex impedance is to be reported, the imaginary part (reactance) must be represented with a separate Variable instance value of ‘reactance’. Reactance values are expressed at the (nominal) relevant operating frequency of the Component (e.g. 50/60Hz for mains electricity feed).

§

Interval

Minimum Interval (in seconds) between (attempted) operations.

§

ItemsPerMessage

Maximum number of ComponentVariable entries that can be sent in one GetReportRequest or GetMonitoringReportRequest message.

§

Label

Label for a component. Specifies a non-unique label to be used in a hierarchy UI rendering, in place of the unique component name and instance

§

Language

Default language code, per RFC 5646, of this Charging Station.

§

Length

General Purpose linear distance measure.

§

LifeTime

Indicates how long it takes until a token expires in the authorization cache since it is last used.

§

Light

(Ambient) light level. The value is in Lux.

§

LimitChangeSignificance

If at the Charging Station side a change in the limit in a ChargingProfile is lower than this percentage, the Charging Station MAY skip sending a NotifyChargingLimitRequest or a TransactionEventRequest message to the CSMS.

§

LocalAuthorizeOffline

Whether the Charging Station, when Offline, will start a transaction for locally-authorized identifiers.

§

LocalFrequencyUpdateThreshold

The amount of change in net frequency in mHz is needed to trigger a recalculation of the setpoint.

§

LocalLoadBalancing

Variable with instances to control local load-balancing.

§

LocalPreAuthorize

Whether the Charging Station, when online, will start a transaction for locally-authorized identifiers without waiting for or requesting an AuthorizeResponse from the CSMS.

§

LogicalParent

Points to a logical parent component, to allow rendering a comprehensive overview of the Charging Station components in a UI.

§

Manufacturer

Component Manufacturer name

§

MasterPassGroupId

IdTokens that have this id as groupId belong to the Master Pass Group.

§

MaxCertificateChainSize

This configuration variable can be used to limit the size of the ‘certificateChain’ field from the CertificateSignedRequest PDU.

§

MaxElements

For TariffCostCtrlr: Specifies the maximum number of prices elements that the Charging Station supports in each energy, _chargingTime, idleTime and fixedFee of a TariffType.

§

MaxEnergyOnInvalidId

Maximum amount of energy in Wh delivered when an identifier is deauthorized by the CSMS after start of a transaction.

§

MaxExternalConstraintsId

Defines the highest value that a charging profile id of a ChargingStationExternalConstraints profile in the Charging Station can have.

§

MaxPeriodicEventStreams

The maximum number of open periodic event streams that Charging Station supports.

§

MaxPriceElements

For ISO15118Ctrlr: The maximum number of priceRuleStacks and priceLevelScheduleEntries that Charging Station is able to accept in a ChargingScheduleType.

§

MaxSoc

The maximum state of charge that a battery will be charged to.

§

Measurands

Measurand(s) to be included in <<metervaluesrequest,MeterValuesRequest>> or <<transactioneventrequest,TransactionEventRequest>>

§

Message

Specific stored message for display.

§

MessageAttemptInterval

How long the Charging Station should wait before resubmitting a TransactionEventRequest message that the CSMS failed to process.

§

MessageAttempts

How often the Charging Station should try to submit a TransactionEventRequest message when the CSMS fails to process it.

§

MessageTimeout

The purpose of the message timeout is to be able to consider a request message as not sent and continue with other tasks when the message did not arrive due to communication errors or software failure.

§

MinimumStatusDuration

Minimum duration that a Charging Station or EVSE status is stable before StatusNotificationRequest is sent to the CSMS.

§

Mode

Operating mode string from among valid options (communicated by OptionList, etc. during capability/configuration discovery).

§

Model

Manufacturer’s Model code/number of Component, including suffixes etc. to identify functional, regional or linguistic variation, but NOT engineering change level internal variation not affecting external behaviour, etc.

§

NetworkAddress

Current network address of a Component.

§

NetworkConfigurationPriority

A comma separated ordered list of the priority of the possible Network Connection Profiles. The list of possible available profile slots for the network configuration profiles SHALL be reported, via the valuesList characteristic of this Variable.

§

NetworkProfileConnectionAttempts

Specifies the number of connection attempts the Charging Station executes before switching to a different profile.

§

NextTimeOffsetTransitionDateTime

Date time of the next time offset transition. On this date time, the clock displayed to the EV driver will be given the new offset as configured via TimeOffsetNextTransition.

§

NonEvseSpecific

For ReservationCtrlr: If this configuration variable is present and set to true: Charging Station supports reservation where EVSE id is not specified.

§

NotificationMaxDelay

For ISO15118Ctrlr: The SECC (EVSE) uses the NotificationMaxDelay element in the EVSEStatus to indicate the time in seconds until it expects the EVCC (EV) to react on the action request indicated in EVSENotification.

§

NotifyChargingLimitWithSchedules

Indicates if the Charging Station should include the externally set charging limit/schedule in the message when it sends a NotifyChargingLimitRequest message.

§

NtpServerUri

This contains the address of the NTP server.

§

NtpSource

Use the NTP server provided via DHCP, or use the manually configured NTP server.

§

OfflineQueuingSeverity

When set and the Charging Station is offline, the Charging Station shall queue any NotifyEventRequest messages triggered by a monitor with a severity number equal to or lower than the severity configured here.

§

OfflineTariffFallbackMessage

Message (and/or tariff information) to be shown to an EV Driver when Charging Station is offline.

§

OfflineThreshold

When the offline period of a Charging Station exceeds the OfflineThreshold it is recommended to send a StatusNotificationRequest for all its Connectors when the Charging Station is back online.

§

OfflineTxForUnknownIdEnabled

If this key exists and is true, the Charging Station supports Unknown Offline Authorization.

§

Operated

The Component operated in an instantaneous, transient, or immediately self-resetting pattern. Used only in event notifications, where it is always true.

§

OperatingTimes

Recurring operating times in iCalendar RRULE format.

§

OrganizationName

The organizationName of the CSO operating the charging station.

§

Overload

Component is in Overload state.

§

Percent

Generic dimensionless value reporting/setting value.

§

PeriodsPerSchedule

Maximum number of periods that may be defined per ChargingSchedule.

§

PhaseRotation

This variable describes the phase rotation of a Component relative to its parent Component, using a

§

Phases3to1

If defined and true, this Charging Station supports switching from 3 to 1 phase during a transaction.

§

PhysicalParent

Points to a physical parent component (container), to allow rendering an overview of the Charging Station component locations in a UI.

§

PnCEnabled

If this variable is true, then ISO 15118 plug and charge as described by use case C07 - Authorization using Contract Certificates is enabled.

§

Policy

Cache Entry Replacement Policy: least recently used, least frequently used, first in first out, other custom mechanism.

§

PostChargingTime

Elapsed time in seconds since last substantive energy transfer

§

Power

Instantaneous (real) Power (measured/calculated, including power factor for AC). Where a component (e.g. AC to DC Power Converter) has multiple power measurements, the default (unkeyed) instance is “input” power.

§

Present

Component exists, but might not be locally configured/wired for use, nor (remotely) Enabled.

§

Problem

Component itself has a ‘Problem’ condition that impacts in any significant way on its normal operation. By definition, ‘Problem’ state includes (logical OR) ‘Fault’ state. ‘Problem’ specifically INCLUDES inability to operate that is propagated (up/down/sideways) from any other associated/connected/containing/contained Component.

§

ProfileStackLevel

Maximum acceptable value for stackLevel in a ChargingProfile.

§

Protecting

Applies to ‘sensor’ type Components that have an associated protection capability, whereby they can disconnect power (e.g. using the main PowerContactor) if the sensed quantity is outside preset/configured limits. If Protecting is true, the Component is actively preventing/interrupting charging.

§

ProtocolAgreed

For ConnectedEV: A string with the following comma-separated items: “<uri>,<major>,<minor>”. This is the protocol uri and version information that was agreed upon between EV and EVSE in the supportedAppProtocolReq handshake from ISO 15118.

§

ProtocolSupported

For ISO15118Ctrlr: A string with the following comma-separated items: “<uri>,<major>,<minor>”. <uri> is in the format as used in the SupportedAppProtocolReq message from ISO 15118-2 and ISO 15118-20. This variable has at most 20 instances, one for each supported protocol version.

§

ProtocolSupportedByEV

For ConnectedEV: A string with the following comma-separated items: “<uri>,<major>,<minor>”. This is information from the SupportedAppProtocolReq message from ISO 15118. Each priority is given its own variable instance. Priority is a number from 1 to 20 as a string.

§

PublicKey

Configuration variable that can be used to retrieve the public key for a meter connected to a specific EVSE.

§

PublicKeyWithSignedMeterValue

This Configuration Variable can be used to configure whether a public key needs to be sent with a signed meter value.

§

QueueAllMessages

When this variable is set to true, the Charging Station will queue all message until they are delivered to the CSMS.

§

RateUnit

A list of supported quantities (A, W) for use in a ChargingSchedule.

§

RegisterValuesWithoutPhases

If this variable reports a value of true, then meter values of measurand Energy.Active.Import.Register will only report the total energy over all phases without reporting the individual phase values.

§

RemainingTimeBulk

Number of seconds remaining to charge to bulk state of charge, given by StateOfChargeBulk.

§

RemainingTimeFull

Number of seconds remaining to charge to 100% state of charge.

§

ReportingValueSize

This Configuration Variable can be used to limit the following fields: GetVariableResult.attributeValue, VariableAttribute.value and EventData.actualValue.

§

RequestMeteringReceipt

For ISO15118Ctrlr: If this variable is true, then Charging Station shall request a metering receipt

§

ResetRetries

Number of times to retry a reset of the Charging Station when a reset was unsuccessful.

§

ResumptionTimeout

This variable defines the maximum number of seconds that a transaction may be interrupted by a power outage and still be resumed afterwards.

§

SampledMeasurands

The set of measurands to be sampled by the DataCollector component.

§

SamplingInterval

The sampling interval in seconds.

§

SeccId

The name of the SECC in the string format as required by ISO 15118.

§

SecurityProfile

This configuration variable is used to report the security profile used by the Charging Station.

§

SendDuringIdle

For AlignedDataCtrlr: If set to true, the Charging Station SHALL only send clock aligned meter values when there is no transaction ongoing.

§

SerialNumber

Serial number of Component.

§

ServiceRenegotiationSupport

For ISO15118Ctrlr: If set to ‘True’ the SECC (EVSE) is capable of ServiceRenegotiation.

§

SetpointPriority

Defines which setpoint shall be used when a ChargingStationExternalConstraints profile

§

SignReadings

If set to true, the Charging Station SHALL include signed meter values in the TransactionEventRequest(Ended).

§

SignStartedReadings

If set to true, the Charging Station SHALL include signed meter values for context = Transaction.Begin in the metervalues field in the TransactionEventRequest(Started or Updated).

§

SignUpdatedReadings

If set to true, the Charging Station SHALL include signed meter values in the metervalues field in the TransactionEventRequest(Updated).

§

SignalStrength

(Radio/Wired/Optical) data signal strength, in ASU (typically 0-31 or 99 for unknown). Or dbmW (typically -140 to -50).

§

SlotStatus

This variable represents the status of the door of the battery slot.

§

SoC

SoC of the component BatteryCartridge which refers to the battery that is inserted at the EVSE.

§

SoH

SoH of the component BatteryCartridge which refers to the battery that is inserted at the EVSE.

§

State

A state code or name identifier string, to allow the internal state of components to be reported and/or controlled

§

StateOfCharge

Energy Storage Device (e.g. battery) state of charge, expressed as a percentage of nominal design 0-100% operating range. The value of StateOfCharge.maxSet represents the maximum state of charge for a full battery and is usually at or near 100%.

§

StateOfChargeBulk

Energy Storage Device (e.g. battery) state of charge up to which fast charging is possible. Above this percentage charging speed will drop significantly.

§

StopTxOnEVSideDisconnect

When set to true, the Charging Station SHALL deauthorize the transaction when the cable is unplugged from the EV.

§

StopTxOnInvalidId

Whether the Charging Station will deauthorize an ongoing transaction when it receives a non- Accepted authorization status in TransactionEventResponse for this transaction.

§

Storage

In bytes. Amount of storage occupied. Storage(maxLimit) specifies absolute limit Storage(MaxSet) restricts usage to specified Max, if supported.

§

SupplyPhases

Number of alternating current phases connected/available. 1 or 3 for AC, 0 means DC (no alternating phases). Null value indicates that the number of phases (e.g. in use) is unknown.

§

SupportedAdditionalPurposes

This configuration variable lists the additional charging profile purposes, that have been introduced in OCPP 2.1, that are supported by the Charging Station.

§

SupportedEnergyTransferModes

Lists the energy transfer services that are supported by the Charging Station.

§

SupportedFormats

For DisplayMessageCtrlr: List of message formats supported by this Charging Station.

§

SupportedIdTokenTypes

The subset of the list of supported IdTokenTypes as defined in Appendix 7.

§

SupportedLimits

This variable defines which transaction limits in TransactionLimitType are supported by the Charging Station.

§

SupportedOperationModes

Lists the V2X operation modes that are supported by the Charging Station.

§

SupportedPriorities

For DisplayMessageCtrlr: List of the priorities supported by this Charging Station.

§

SupportedProviders

A comma-separated list of all providers (eMSPs) that are supported on this Charging Station. The providers are listed using country and provider ID from the EMAID, as defined in ISO 15118-20.

§

SupportedStates

For DisplayMessageCtrlr: List of the states during which to display a message supported by this Charging Station.

§

SupportsDynamicProfiles

When this variable has value True, then the Charging Station supports charging profiles of type Dynamic.

§

SupportsEvseSleep

When reported as true the Charging Station supports the evseSleep flag in a ChargingSchedulePeriod, which requests the EVSE electronics to go to sleep during operationMode = ‘Idle’.

§

SupportsExpiryDateTime

For LocalAuthListCtrlr: When set to true Charging Station will disregard idTokens for authorization as if not present in the Local Authorization List when current date/time is past the value of cacheExpiryDateTime.

§

SupportsLimitAtSoC

When this variable has value True, then the Charging Station supports the field limitAtSoC in ChargingSchedul, which will cap the limit or setpoint in the ChargingSchedulePeriodType by the value of limitAtSoC.limit.

§

SupportsMaxOfflineDuration

When this variable has value True, then the Charging Station supports the fields maxOfflineDuration and invalidAfterOfflineDuration in ChargingProfile.

§

SupportsRandomizedDelay

When this variable has value True, then the Charging Station supports the field randomizedDelay in ChargingSchedule, which will delay the start of each charging schedule period by a random number between 0 and randomizedDelay.

§

SupportsUseLocalTime

When this variable has value True, then the Charging Station supports the field useLocalTime in ChargingSchedule.

§

Suspending

If Suspending is true, the Component can is currently suspending charging.

§

Suspension

Applies to ‘sensor’ type Components that have a charging suspension capability, typically for safety or equipment protection reasons. If Suspension is true, the component can suspend charging when the sensed quantity is outside preset/configured limits.

§

TargetSoc

For BatterySwapCtrlr: The state of charge that a battery must have in order to be eligible for swapping.

§

TariffFallbackMessage

Message (and/or tariff information) to be shown to an EV Driver when there is no driver specific tariff information available.

§

Temperature

Temperature(s) of component (in Celsius, by default). Components may have multiple indexed temperature sensors.

§

Time

Point in time value, in ISO 8601 datetime format. Time zone optional.

§

TimeAdjustmentReportingThreshold

When the clock time is adjusted forwards or backwards for more then TimeAdjustmentReportingThreshold number of seconds, a SecurityEventNotification( ‘SettingSystemTime’ ) is sent by the charging station.

§

TimeOffset

A Time Offset with respect to Coordinated Universal Time (aka UTC or Greenwich Mean Time) in the form of an [RFC3339] time (zone) offset suffix, including the mandatory “+” or “-“ prefix.

§

TimeSource

Via this variable, the Charging Station provides the CSMS with the option to configure a clock source.

§

TimeZone

Configured current local time zone in the format: ‘Europe/Oslo’, ‘Asia/Singapore’ etc.

§

Timeout

Generic timeout value for Component operation (in seconds).

Also listed as: For BatterySwapCtrlr: Timeout in seconds in which a set of batteries must be inserted or removed after successful authorization.

§

Token

String of bytes representing an ID token.

§

TokenType

Type of Token. Value is one of IdTokenEnumStringType (See Appendix 7).

§

TotalCostFallbackMessage

Message to be shown to an EV Driver when the Charging Station cannot retrieve the cost for a transaction at the end of the transaction.

§

Tries

Number of attempts done by a Component.

§

Tripped

Single-shot device requires explicit intervention to re-prime/activate to normal.

§

TxBeforeAcceptedEnabled

With this configuration variable the Charging Station can be configured to allow charging before having received a BootNotificationResponse with status: Accepted.

§

TxEndedInterval

Interval between sampling of metering (or other) data, intended to be transmitted in the TransactionEventRequest(Ended) message.

§

TxEndedMeasurands

Sampled measurands to be included in the meterValues element of TransactionEventRequest(Ended).

§

TxStartPoint

Start points for a transaction.

§

TxStartedMeasurands

Sampled measurands to be included in the meterValues element of TransactionEventRequest(Started).

§

TxStopPoint

Stop points of a transaction.

§

TxUpdatedInterval

Interval between sampling of metering (or other) data, intended to be transmitted in the TransactionEventRequest(Updated) message.

§

TxUpdatedMeasurands

Sampled measurands to be included in the meterValues element of TransactionEventRequest(Updated).

§

UnlockOnEVSideDisconnect

When set to true, the Charging Station SHALL unlock the cable on the Charging Station side when the cable is unplugged at the EV.

§

UpstreamInterval

Interval between sampling of metering (or other) data, intended to be transmitted via TransactionEventRequest(Updated) messages for location = Upstream only.

§

UpstreamMeasurands

Sampled measurands to be included in the meterValues element of every TransactionEventRequest(Updated) for location = Upstream only.

§

V2GCertificateInstallationEnabled

If this variable is true, then ISO 15118 V2G Charging Station certificate installation as described by use case A02 - Update Charging Station Certificate by request of CSMS

§

VehicleCertificate

For ConnectedEV: The PEM encoded X.509 leaf/intermediate/root certificate when present in the vehicle certificate chain.

§

VehicleId

ID that EV provides to charging station. Encoded as a hexbinary string. In ISO 15118 the EVCCID is 6 bytes (MAC address), in CHAdeMO the vehicle id can be 24 bytes.

§

VersionDate

[RFC3339]

§

VersionNumber

Version number of hardware

§

VoltageImbalance

Percentage voltage imbalance in three phase supply.

§

WorkingMode

This variable represents the current working mode of the battery in BatteryCartridge component.

§

VendorName

Listed in the specification’s device model table but not in its dedicated name table.

§

SupportedIdTokenType

Listed in the specification’s device model table but not in its dedicated name table.

§

SelftestActive

Listed in the specification’s device model table but not in its dedicated name table.

§

CHAdeMOProtocolNumber

Listed in the specification’s device model table but not in its dedicated name table.

§

VehicleStatus

Listed in the specification’s device model table but not in its dedicated name table.

§

DynamicControl

Listed in the specification’s device model table but not in its dedicated name table.

§

HighCurrentControl

Listed in the specification’s device model table but not in its dedicated name table.

§

HighVoltageControl

Listed in the specification’s device model table but not in its dedicated name table.

§

AutoManufacturerCode

Listed in the specification’s device model table but not in its dedicated name table.

§

VehicleID

Listed in the specification’s device model table but not in its dedicated name table.

§

BatteryCapacity

Listed in the specification’s device model table but not in its dedicated name table.

§

ValueSize

Listed in the specification’s device model table but not in its dedicated name table.

§

EvseId

Listed in the specification’s device model table but not in its dedicated name table.

§

MaxScheduleEntries

Listed in the specification’s device model table but not in its dedicated name table.

§

RequestedEnergyTransferMode

Listed in the specification’s device model table but not in its dedicated name table.

§

NotificationDelay

Listed in the specification’s device model table but not in its dedicated name table.

§

Capacity

Listed in the specification’s device model table but not in its dedicated name table.

§

MonitoringBase

Listed in the specification’s device model table but not in its dedicated name table.

§

MonitoringLevel

Listed in the specification’s device model table but not in its dedicated name table.

§

RetryBackOffRandomRange

Listed in the specification’s device model table but not in its dedicated name table.

§

RetryBackOffRepeatTimes

Listed in the specification’s device model table but not in its dedicated name table.

§

RetryBackOffWaitMinimum

Listed in the specification’s device model table but not in its dedicated name table.

§

WebSocketPingInterval

Listed in the specification’s device model table but not in its dedicated name table.

§

EnergyTransferResumptionRandomRange

Listed in the specification’s device model table but not in its dedicated name table.

§

MaxW

Listed in the specification’s device model table but not in its dedicated name table.

§

OverExcitedW

Listed in the specification’s device model table but not in its dedicated name table.

§

OverExcitedPF

Listed in the specification’s device model table but not in its dedicated name table.

§

UnderExcitedW

Listed in the specification’s device model table but not in its dedicated name table.

§

UnderExcitedPF

Listed in the specification’s device model table but not in its dedicated name table.

§

MaxVA

Listed in the specification’s device model table but not in its dedicated name table.

§

MaxVar

Listed in the specification’s device model table but not in its dedicated name table.

§

MaxVarNeg

Listed in the specification’s device model table but not in its dedicated name table.

§

MaxChargeRateW

Listed in the specification’s device model table but not in its dedicated name table.

§

MaxChargeRateVA

Listed in the specification’s device model table but not in its dedicated name table.

§

VNom

Listed in the specification’s device model table but not in its dedicated name table.

§

MaxV

Listed in the specification’s device model table but not in its dedicated name table.

§

MinV

Listed in the specification’s device model table but not in its dedicated name table.

§

ModesSupported

Listed in the specification’s device model table but not in its dedicated name table.

§

InverterManufacturer

Listed in the specification’s device model table but not in its dedicated name table.

§

InverterModel

Listed in the specification’s device model table but not in its dedicated name table.

§

InverterSerialNumber

Listed in the specification’s device model table but not in its dedicated name table.

§

InverterSwVersion

Listed in the specification’s device model table but not in its dedicated name table.

§

InverterHwVersion

Listed in the specification’s device model table but not in its dedicated name table.

§

IslandingDetectionMethod

Listed in the specification’s device model table but not in its dedicated name table.

§

IslandingDetectionTripTime

Listed in the specification’s device model table but not in its dedicated name table.

§

ReactiveSusceptance

Listed in the specification’s device model table but not in its dedicated name table.

§

TargetSoC

Listed in the specification’s device model table but not in its dedicated name table.

§

OcppCsmsUrl

Listed in the specification’s device model table but not in its dedicated name table.

§

OcppInterface

Listed in the specification’s device model table but not in its dedicated name table.

§

OcppTransport

Listed in the specification’s device model table but not in its dedicated name table.

§

OcppVersion

Listed in the specification’s device model table but not in its dedicated name table.

§

CsmsRootCertificateHashAlgorithm

Listed in the specification’s device model table but not in its dedicated name table.

§

CsmsRootCertificateIssuerKeyHash

Listed in the specification’s device model table but not in its dedicated name table.

§

CsmsRootCertificateIssuerNameHash

Listed in the specification’s device model table but not in its dedicated name table.

§

CsmsRootCertificateSerialNumber

Listed in the specification’s device model table but not in its dedicated name table.

§

VpnEnabled

Listed in the specification’s device model table but not in its dedicated name table.

§

VpnType

Listed in the specification’s device model table but not in its dedicated name table.

§

VpnServer

Listed in the specification’s device model table but not in its dedicated name table.

§

VpnUser

Listed in the specification’s device model table but not in its dedicated name table.

§

VpnGroup

Listed in the specification’s device model table but not in its dedicated name table.

§

VpnPassword

Listed in the specification’s device model table but not in its dedicated name table.

§

VpnKey

Listed in the specification’s device model table but not in its dedicated name table.

§

ApnEnabled

Listed in the specification’s device model table but not in its dedicated name table.

§

Apn

Listed in the specification’s device model table but not in its dedicated name table.

§

ApnUserName

Listed in the specification’s device model table but not in its dedicated name table.

§

ApnPassword

Listed in the specification’s device model table but not in its dedicated name table.

§

SimPin

Listed in the specification’s device model table but not in its dedicated name table.

§

PreferredNetwork

Listed in the specification’s device model table but not in its dedicated name table.

§

UseOnlyPreferredNetwork

Listed in the specification’s device model table but not in its dedicated name table.

§

ApnAuthentication

Listed in the specification’s device model table but not in its dedicated name table.

§

AuthorizeDirectPayment

Listed in the specification’s device model table but not in its dedicated name table.

§

AuthorizationAmount

Listed in the specification’s device model table but not in its dedicated name table.

§

IncrementalAuthorizationAmount

Listed in the specification’s device model table but not in its dedicated name table.

§

IncrementalAuthorizationThreshold

Listed in the specification’s device model table but not in its dedicated name table.

§

PaymentDetails

Listed in the specification’s device model table but not in its dedicated name table.

§

SettlementByCSMS

Listed in the specification’s device model table but not in its dedicated name table.

§

ReceiptServerUrl

Listed in the specification’s device model table but not in its dedicated name table.

§

ReceiptByCSMS

Listed in the specification’s device model table but not in its dedicated name table.

§

Merchant

Listed in the specification’s device model table but not in its dedicated name table.

§

TerminalID

Listed in the specification’s device model table but not in its dedicated name table.

§

PaymentServiceProvider

Listed in the specification’s device model table but not in its dedicated name table.

§

Connected

Listed in the specification’s device model table but not in its dedicated name table.

§

URLTemplate

Listed in the specification’s device model table but not in its dedicated name table.

§

URLParameters

Listed in the specification’s device model table but not in its dedicated name table.

§

TOTPVersion

Listed in the specification’s device model table but not in its dedicated name table.

§

ChargingStationId

Listed in the specification’s device model table but not in its dedicated name table.

§

ValidityTime

Listed in the specification’s device model table but not in its dedicated name table.

§

SharedSecret

Listed in the specification’s device model table but not in its dedicated name table.

§

QRCodeQuality

Listed in the specification’s device model table but not in its dedicated name table.

§

Other(String<50usize>)

A value this version’s specification doesn’t define – typically a vendor-specific one, which OCPP explicitly permits.

Bounded at 50 bytes, the same maxLength the wire field carries, so anything the field can hold this can hold. Prefer Self::from_wire_or_other over constructing this directly: it returns the standardized variant when the value is one, keeping a single representation per wire string.

Implementations§

Source§

impl VariableName

Source

pub const ALL: &'static [Self]

Every value this version’s specification defines (328), in spec order.

Does not include Self::Other, which is unbounded in the values it can hold.

Source

pub fn as_str(&self) -> &str

This value as it appears on the wire.

Source

pub fn from_wire(value: &str) -> Option<Self>

Parses a wire value, returning None for values the specification doesn’t define.

Use this to ask “is this one of the spec’s values?”. To accept any value, use Self::from_wire_or_other.

Source

pub fn from_wire_or_other(value: &str) -> Result<Self, ValueTooLong>

Parses any wire value, falling back to Self::Other.

Fails only if value is longer than the specification’s maxLength for this field, in which case it isn’t a value the field could have carried in the first place.

Source

pub fn is_standardized(&self) -> bool

Whether this is one of the values the specification defines, as opposed to a vendor’s own.

Source

pub fn data_type(&self) -> Option<&'static str>

The spec’s data type for this variable, as named in the device model tables (e.g. decimal, OptionList).

Source

pub fn unit(&self) -> Option<&'static str>

The variable’s unit, where the spec states one.

Trait Implementations§

Source§

impl Clone for VariableName

Source§

fn clone(&self) -> VariableName

Returns a duplicate of the value. Read more
1.0.0 (const: unstable) · Source§

fn clone_from(&mut self, source: &Self)

Performs copy-assignment from source. Read more
Source§

impl Debug for VariableName

Source§

fn fmt(&self, f: &mut Formatter<'_>) -> Result

Formats the value using the given formatter. Read more
Source§

impl<'de> Deserialize<'de> for VariableName

Available on crate feature serde only.
Source§

fn deserialize<D: Deserializer<'de>>(deserializer: D) -> Result<Self, D::Error>

Deserialize this value from the given Serde deserializer. Read more
Source§

impl Display for VariableName

Source§

fn fmt(&self, f: &mut Formatter<'_>) -> Result

Formats the value using the given formatter. Read more
Source§

impl Eq for VariableName

Source§

impl FromStr for VariableName

Source§

type Err = ValueTooLong

The associated error which can be returned from parsing.
Source§

fn from_str(value: &str) -> Result<Self, Self::Err>

Parses a string s to return a value of this type. Read more
Source§

impl Hash for VariableName

Source§

fn hash<H: Hasher>(&self, state: &mut H)

Feeds this value into the given Hasher. Read more
1.3.0 · Source§

fn hash_slice<H>(data: &[Self], state: &mut H)
where H: Hasher, Self: Sized,

Feeds a slice of this type into the given Hasher. Read more
Source§

impl Ord for VariableName

Source§

fn cmp(&self, other: &Self) -> Ordering

This method returns an Ordering between self and other. Read more
1.21.0 (const: unstable) · Source§

fn max(self, other: Self) -> Self
where Self: Sized,

Compares and returns the maximum of two values. Read more
1.21.0 (const: unstable) · Source§

fn min(self, other: Self) -> Self
where Self: Sized,

Compares and returns the minimum of two values. Read more
1.50.0 (const: unstable) · Source§

fn clamp(self, min: Self, max: Self) -> Self
where Self: Sized,

Restrict a value to a certain interval. Read more
Source§

impl PartialEq for VariableName

Source§

fn eq(&self, other: &Self) -> bool

Equality operator ==. Read more
1.0.0 (const: unstable) · Source§

fn ne(&self, other: &Rhs) -> bool

Inequality operator !=. Read more
Source§

impl PartialOrd for VariableName

Source§

fn partial_cmp(&self, other: &Self) -> Option<Ordering>

This method returns an ordering between self and other values if one exists. Read more
1.0.0 (const: unstable) · Source§

fn lt(&self, other: &Rhs) -> bool

Tests less than (for self and other) and is used by the < operator. Read more
1.0.0 (const: unstable) · Source§

fn le(&self, other: &Rhs) -> bool

Tests less than or equal to (for self and other) and is used by the <= operator. Read more
1.0.0 (const: unstable) · Source§

fn gt(&self, other: &Rhs) -> bool

Tests greater than (for self and other) and is used by the > operator. Read more
1.0.0 (const: unstable) · Source§

fn ge(&self, other: &Rhs) -> bool

Tests greater than or equal to (for self and other) and is used by the >= operator. Read more
Source§

impl Serialize for VariableName

Available on crate feature serde only.
Source§

fn serialize<S: Serializer>(&self, serializer: S) -> Result<S::Ok, S::Error>

Serialize this value into the given Serde serializer. Read more

Auto Trait Implementations§

Blanket Implementations§

Source§

impl<T> Any for T
where T: 'static + ?Sized,

Source§

fn type_id(&self) -> TypeId

Gets the TypeId of self. Read more
Source§

impl<T> Borrow<T> for T
where T: ?Sized,

Source§

fn borrow(&self) -> &T

Immutably borrows from an owned value. Read more
Source§

impl<T> BorrowMut<T> for T
where T: ?Sized,

Source§

fn borrow_mut(&mut self) -> &mut T

Mutably borrows from an owned value. Read more
Source§

impl<T> CloneToUninit for T
where T: Clone,

Source§

unsafe fn clone_to_uninit(&self, dest: *mut u8)

🔬This is a nightly-only experimental API. (clone_to_uninit)
Performs copy-assignment from self to dest. Read more
Source§

impl<T> DeserializeOwned for T
where T: for<'de> Deserialize<'de>,

Source§

impl<T> From<T> for T

Source§

fn from(t: T) -> T

Returns the argument unchanged.

Source§

impl<T, U> Into<U> for T
where U: From<T>,

Source§

fn into(self) -> U

Calls U::from(self).

That is, this conversion is whatever the implementation of From<T> for U chooses to do.

Source§

impl<T> ToOwned for T
where T: Clone,

Source§

type Owned = T

The resulting type after obtaining ownership.
Source§

fn to_owned(&self) -> T

Creates owned data from borrowed data, usually by cloning. Read more
Source§

fn clone_into(&self, target: &mut T)

Uses borrowed data to replace owned data, usually by cloning. Read more
Source§

impl<T> ToString for T
where T: Display + ?Sized,

Source§

fn to_string(&self) -> String

Converts the given value to a String. Read more
Source§

impl<T, U> TryFrom<U> for T
where U: Into<T>,

Source§

type Error = Infallible

The type returned in the event of a conversion error.
Source§

fn try_from(value: U) -> Result<T, <T as TryFrom<U>>::Error>

Performs the conversion.
Source§

impl<T, U> TryInto<U> for T
where U: TryFrom<T>,

Source§

type Error = <U as TryFrom<T>>::Error

The type returned in the event of a conversion error.
Source§

fn try_into(self) -> Result<U, <U as TryFrom<T>>::Error>

Performs the conversion.