pub fn parse_request(pdu: &[u8]) -> Result<ModbusRequest, u8>Expand description
Decode a PDU.
The error carries the exception code the specification prescribes, which the caller
answers with directly — no model round-trip, because none of these is a decision:
an unknown function code is always 0x01, a quantity of 0 is always 0x03.