Enum lpc845_pac::capt::ctrl::TRIGGER_A [−][src]
pub enum TRIGGER_A {
USES_YH_GPIO,
ACMP,
}
Expand description
This selects what is being used as the trigger
Value on reset: 0
Variants
0: Uses YH GPIO. This is not normally used except in Low-power mode. But, it can be used with POLLNOW to baseline that measurement.
1: ACMP (if fitted). This assumes the ACMP state is fed in asynchronously and it will sample.