Expand description
Configuration register 0
Structs
Type Definitions
Field
BIT_NUM reader - This register is used to set the length of data. 0: 5 bits. 1: 6 bits. 2: 7 bits. 3: 8 bits.Field
BIT_NUM writer - This register is used to set the length of data. 0: 5 bits. 1: 6 bits. 2: 7 bits. 3: 8 bits.Field
CLK_EN reader - 1: Force clock on for registers. 0: Support clock only when application writes registers.Field
CLK_EN writer - 1: Force clock on for registers. 0: Support clock only when application writes registers.Field
CTS_INV reader - Set this bit to invert the level of UART CTS signal.Field
CTS_INV writer - Set this bit to invert the level of UART CTS signal.Field
DSR_INV reader - Set this bit to invert the level of UART DSR signal.Field
DSR_INV writer - Set this bit to invert the level of UART DSR signal.Field
DTR_INV reader - Set this bit to invert the level of UART DTR signal.Field
DTR_INV writer - Set this bit to invert the level of UART DTR signal.Field
ERR_WR_MASK reader - 1: The receiver stops storing data into FIFO when data is wrong. 0: The receiver stores the data even if the received data is wrong.Field
ERR_WR_MASK writer - 1: The receiver stops storing data into FIFO when data is wrong. 0: The receiver stores the data even if the received data is wrong.Field
IRDA_DPLX reader - Set this bit to enable IrDA loopback mode.Field
IRDA_DPLX writer - Set this bit to enable IrDA loopback mode.Field
IRDA_EN reader - Set this bit to enable IrDA protocol.Field
IRDA_EN writer - Set this bit to enable IrDA protocol.Field
IRDA_RX_INV reader - Set this bit to invert the level of IrDA receiver.Field
IRDA_RX_INV writer - Set this bit to invert the level of IrDA receiver.Field
IRDA_TX_EN reader - This is the start enable bit for IrDA transmitter.Field
IRDA_TX_EN writer - This is the start enable bit for IrDA transmitter.Field
IRDA_TX_INV reader - Set this bit to invert the level of IrDA transmitter.Field
IRDA_TX_INV writer - Set this bit to invert the level of IrDA transmitter.Field
IRDA_WCTL reader - 1: The IrDA transmitter’s 11th bit is the same as 10th bit. 0: Set IrDA transmitter’s 11th bit to 0.Field
IRDA_WCTL writer - 1: The IrDA transmitter’s 11th bit is the same as 10th bit. 0: Set IrDA transmitter’s 11th bit to 0.Field
LOOPBACK reader - Set this bit to enable UART loopback test mode.Field
LOOPBACK writer - Set this bit to enable UART loopback test mode.Field
MEM_CLK_EN reader - The signal to enable UART RAM clock gating. 1: UART RAM powers on, the data of which can be read and written. 0: UART RAM powers down.Field
MEM_CLK_EN writer - The signal to enable UART RAM clock gating. 1: UART RAM powers on, the data of which can be read and written. 0: UART RAM powers down.Field
PARITY_EN reader - Set this bit to enable UART parity check.Field
PARITY_EN writer - Set this bit to enable UART parity check.Field
PARITY reader - This register is used to configure the parity check mode. 0: even. 1: odd.Field
PARITY writer - This register is used to configure the parity check mode. 0: even. 1: odd.Field
RTS_INV reader - Set this bit to invert the level of UART RTS signal.Field
RTS_INV writer - Set this bit to invert the level of UART RTS signal.Field
RXD_INV reader - Set this bit to invert the level of UART RXD signal.Field
RXD_INV writer - Set this bit to invert the level of UART RXD signal.Field
RXFIFO_RST reader - Set this bit to reset the UART RX FIFO.Field
RXFIFO_RST writer - Set this bit to reset the UART RX FIFO.Field
STOP_BIT_NUM reader - This register is used to set the length of stop bit. 1: 1 bit. 2: 1.5 bits. 3: 2 bits.Field
STOP_BIT_NUM writer - This register is used to set the length of stop bit. 1: 1 bit. 2: 1.5 bits. 3: 2 bits.Field
SW_DTR reader - This register is used to configure the software DTR signal which is used in software flow control.Field
SW_DTR writer - This register is used to configure the software DTR signal which is used in software flow control.Field
SW_RTS reader - This register is used to configure the software RTS signal which is used in software flow control.Field
SW_RTS writer - This register is used to configure the software RTS signal which is used in software flow control.Field
TICK_REF_ALWAYS_ON reader - This register is used to select the clock. 1: APB_CLK. 0: REF_TICK.Field
TICK_REF_ALWAYS_ON writer - This register is used to select the clock. 1: APB_CLK. 0: REF_TICK.Field
TXD_BRK reader - Set this bit to enable the transmitter to send NULL characters when the process of sending data is done.Field
TXD_BRK writer - Set this bit to enable the transmitter to send NULL characters when the process of sending data is done.Field
TXD_INV reader - Set this bit to invert the level of UART TXD signal.Field
TXD_INV writer - Set this bit to invert the level of UART TXD signal.Field
TXFIFO_RST reader - Set this bit to reset the UART TX FIFO.Field
TXFIFO_RST writer - Set this bit to reset the UART TX FIFO.Field
TX_FLOW_EN reader - Set this bit to enable flow control function for the transmitter.Field
TX_FLOW_EN writer - Set this bit to enable flow control function for the transmitter.