Type Alias esp32::sdhost::cmd::R

source ·
pub type R = R<CMD_SPEC>;
Expand description

Register CMD reader

Aliased Type§

struct R { /* private fields */ }

Implementations§

source§

impl R

source

pub fn index(&self) -> INDEX_R

Bits 0:5 - Command index.

source

pub fn response_expect(&self) -> RESPONSE_EXPECT_R

Bit 6 - 0: No response expected from card; 1: Response expected from card.

source

pub fn response_length(&self) -> RESPONSE_LENGTH_R

Bit 7 - 0: Short response expected from card; 1: Long response expected from card.

source

pub fn check_response_crc(&self) -> CHECK_RESPONSE_CRC_R

Bit 8 - 0: Do not check; 1: Check response CRC. Some of command responses do not return valid CRC bits. Software should disable CRC checks for those commands in order to disable CRC checking by controller.

source

pub fn data_expected(&self) -> DATA_EXPECTED_R

Bit 9 - 0: No data transfer expected; 1: Data transfer expected.

source

pub fn read_write(&self) -> READ_WRITE_R

Bit 10 - 0: Read from card; 1: Write to card. Don’t care if no data is expected from card.

source

pub fn transfer_mode(&self) -> TRANSFER_MODE_R

Bit 11 - Block data transfer command; 1: Stream data transfer command. Don’t care if no data expected.

source

pub fn send_auto_stop(&self) -> SEND_AUTO_STOP_R

Bit 12 - 0: No stop command is sent at the end of data transfer; 1: Send stop command at the end of data transfer.

source

pub fn wait_prvdata_complete(&self) -> WAIT_PRVDATA_COMPLETE_R

Bit 13 - 0: Send command at once, even if previous data transfer has not completed; 1: Wait for previous data transfer to complete before sending Command. The SDHOST_WAIT_PRVDATA_COMPLETE] = 0 option is typically used to query status of card during data transfer or to stop current data transfer. SDHOST_CARD_NUMBERr should be same as in previous command.

source

pub fn stop_abort_cmd(&self) -> STOP_ABORT_CMD_R

Bit 14 - 0: Neither stop nor abort command can stop current data transfer. If abort is sent to function-number currently selected or not in data-transfer mode, then bit should be set to 0; 1: Stop or abort command intended to stop current data transfer in progress. When open-ended or predefined data transfer is in progress, and host issues stop or abort command to stop data transfer, bit should be set so that command/data state-machines of CIU can return correctly to idle state.

source

pub fn send_initialization(&self) -> SEND_INITIALIZATION_R

Bit 15 - 0: Do not send initialization sequence (80 clocks of 1) before sending this command; 1: Send initialization sequence before sending this command. After powered on, 80 clocks must be sent to card for initialization before sending any commands to card. Bit should be set while sending first command to card so that controller will initialize clocks before sending command to card.

source

pub fn card_number(&self) -> CARD_NUMBER_R

Bits 16:20 - Card number in use. Represents physical slot number of card being accessed. In SD-only mode, up to two cards are supported.

source

pub fn update_clock_registers_only(&self) -> UPDATE_CLOCK_REGISTERS_ONLY_R

Bit 21 - 0: Normal command sequence; 1: Do not send commands, just update clock register value into card clock domain. Following register values are transferred into card clock domain: CLKDIV, CLRSRC, and CLKENA. Changes card clocks (change frequency, truncate off or on, and set low-frequency mode). This is provided in order to change clock frequency or stop clock without having to send command to cards. During normal command sequence, when sdhost_update_clock_registers_only = 0, following control registers are transferred from BIU to CIU: CMD, CMDARG, TMOUT, CTYPE, BLKSIZ, and BYTCNT. CIU uses new register values for new command sequence to card(s). When bit is set, there are no Command Done interrupts because no command is sent to SD_MMC_CEATA cards.

source

pub fn read_ceata_device(&self) -> READ_CEATA_DEVICE_R

Bit 22 - Read access flag. 0: Host is not performing read access (RW_REG or RW_BLK)towards CE-ATA device; 1: Host is performing read access (RW_REG or RW_BLK) towards CE-ATA device. Software should set this bit to indicate that CE-ATA device is being accessed for read transfer. This bit is used to disable read data timeout indication while performing CE-ATA read transfers. Maximum value of I/O transmission delay can be no less than 10 seconds. SD/MMC should not indicate read data timeout while waiting for data from CE-ATA device.

source

pub fn ccs_expected(&self) -> CCS_EXPECTED_R

Bit 23 - Expected Command Completion Signal (CCS) configuration. 0: Interrupts are not enabled in CE-ATA device (nIEN = 1 in ATA control register), or command does not expect CCS from device; 1: Interrupts are enabled in CE-ATA device (nIEN = 0), and RW_BLK command expects command completion signal from CE-ATA device. If the command expects Command Completion Signal (CCS) from the CE-ATA device, the software should set this control bit. SD/MMC sets Data Transfer Over (DTO) bit in RINTSTS register and generates interrupt to host if Data Transfer Over interrupt is not masked.

source

pub fn use_hole(&self) -> USE_HOLE_R

Bit 29 - Use Hold Register. 0: CMD and DATA sent to card bypassing HOLD Register; 1: CMD and DATA sent to card through the HOLD Register.

source

pub fn start_cmd(&self) -> START_CMD_R

Bit 31 - Start command. Once command is served by the CIU, this bit is automatically cleared. When this bit is set, host should not attempt to write to any command registers. If a write is attempted, hardware lock error is set in raw interrupt register. Once command is sent and a response is received from SD_MMC_CEATA cards, Command Done bit is set in the raw interrupt Register.