pub struct SolidStateRelayV2Bricklet { /* private fields */ }
Expand description

Controls AC and DC Solid State Relays

Implementations

Creates an object with the unique device ID uid. This object can then be used after the IP Connection ip_connection is connected.

Returns the response expected flag for the function specified by the function ID parameter. It is true if the function is expected to send a response, false otherwise.

For getter functions this is enabled by default and cannot be disabled, because those functions will always send a response. For callback configuration functions it is enabled by default too, but can be disabled by set_response_expected. For setter functions it is disabled by default and can be enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is send and errors are silently ignored, because they cannot be detected.

See set_response_expected for the list of function ID constants available for this function.

Changes the response expected flag of the function specified by the function ID parameter. This flag can only be changed for setter (default value: false) and callback configuration functions (default value: true). For getter functions it is always enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is send and errors are silently ignored, because they cannot be detected.

Changes the response expected flag for all setter and callback configuration functions of this device at once.

This receiver is triggered whenever the monoflop timer reaches 0. The parameter is the current state of the relay (the state after the monoflop).

Sets the state of the relays true means on and false means off.

Running monoflop timers will be overwritten if this function is called.

The default value is false.

Returns the state of the relay, true means on and false means off.

The first parameter is the desired state of the relay (true means on and false means off). The second parameter indicates the time (in ms) that the relay should hold the state.

If this function is called with the parameters (true, 1500): The relay will turn on and in 1.5s it will turn off again.

A monoflop can be used as a failsafe mechanism. For example: Lets assume you have a RS485 bus and a Solid State Relay Bricklet connected to one of the slave stacks. You can now call this function every second, with a time parameter of two seconds. The relay will be on all the time. If now the RS485 connection is lost, the relay will turn off in at most two seconds.

Returns the current state and the time as set by set_monoflop as well as the remaining time until the state flips.

If the timer is not running currently, the remaining time will be returned as 0.

Returns the error count for the communication between Brick and Bricklet.

The errors are divided into

  • ACK checksum errors,
  • message checksum errors,
  • framing errors and
  • overflow errors.

The errors counts are for errors that occur on the Bricklet side. All Bricks have a similar function that returns the errors on the Brick side.

Sets the bootloader mode and returns the status after the requested mode change was instigated.

You can change from bootloader mode to firmware mode and vice versa. A change from bootloader mode to firmware mode will only take place if the entry function, device identifier and CRC are present and correct.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

Associated constants:

  • SOLID_STATE_RELAY_V2_BRICKLET_BOOTLOADER_MODE_BOOTLOADER
  • SOLID_STATE_RELAY_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE
  • SOLID_STATE_RELAY_V2_BRICKLET_BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT
  • SOLID_STATE_RELAY_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT
  • SOLID_STATE_RELAY_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT
  • SOLID_STATE_RELAY_V2_BRICKLET_BOOTLOADER_STATUS_OK
  • SOLID_STATE_RELAY_V2_BRICKLET_BOOTLOADER_STATUS_INVALID_MODE
  • SOLID_STATE_RELAY_V2_BRICKLET_BOOTLOADER_STATUS_NO_CHANGE
  • SOLID_STATE_RELAY_V2_BRICKLET_BOOTLOADER_STATUS_ENTRY_FUNCTION_NOT_PRESENT
  • SOLID_STATE_RELAY_V2_BRICKLET_BOOTLOADER_STATUS_DEVICE_IDENTIFIER_INCORRECT
  • SOLID_STATE_RELAY_V2_BRICKLET_BOOTLOADER_STATUS_CRC_MISMATCH

Returns the current bootloader mode, see set_bootloader_mode.

Associated constants:

  • SOLID_STATE_RELAY_V2_BRICKLET_BOOTLOADER_MODE_BOOTLOADER
  • SOLID_STATE_RELAY_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE
  • SOLID_STATE_RELAY_V2_BRICKLET_BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT
  • SOLID_STATE_RELAY_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT
  • SOLID_STATE_RELAY_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT

Sets the firmware pointer for write_firmware. The pointer has to be increased by chunks of size 64. The data is written to flash every 4 chunks (which equals to one page of size 256).

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

Writes 64 Bytes of firmware at the position as written by set_write_firmware_pointer before. The firmware is written to flash every 4 chunks.

You can only write firmware in bootloader mode.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

Sets the status LED configuration. By default the LED shows communication traffic between Brick and Bricklet, it flickers once for every 10 received data packets.

You can also turn the LED permanently on/off or show a heartbeat.

If the Bricklet is in bootloader mode, the LED is will show heartbeat by default.

Associated constants:

  • SOLID_STATE_RELAY_V2_BRICKLET_STATUS_LED_CONFIG_OFF
  • SOLID_STATE_RELAY_V2_BRICKLET_STATUS_LED_CONFIG_ON
  • SOLID_STATE_RELAY_V2_BRICKLET_STATUS_LED_CONFIG_SHOW_HEARTBEAT
  • SOLID_STATE_RELAY_V2_BRICKLET_STATUS_LED_CONFIG_SHOW_STATUS

Returns the configuration as set by set_status_led_config

Associated constants:

  • SOLID_STATE_RELAY_V2_BRICKLET_STATUS_LED_CONFIG_OFF
  • SOLID_STATE_RELAY_V2_BRICKLET_STATUS_LED_CONFIG_ON
  • SOLID_STATE_RELAY_V2_BRICKLET_STATUS_LED_CONFIG_SHOW_HEARTBEAT
  • SOLID_STATE_RELAY_V2_BRICKLET_STATUS_LED_CONFIG_SHOW_STATUS

Returns the temperature in °C as measured inside the microcontroller. The value returned is not the ambient temperature!

The temperature is only proportional to the real temperature and it has bad accuracy. Practically it is only useful as an indicator for temperature changes.

Calling this function will reset the Bricklet. All configurations will be lost.

After a reset you have to create new device objects, calling functions on the existing ones will result in undefined behavior!

Writes a new UID into flash. If you want to set a new UID you have to decode the Base58 encoded UID string into an integer first.

We recommend that you use Brick Viewer to change the UID.

Returns the current UID as an integer. Encode as Base58 to get the usual string version.

Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.

The position can be ‘a’, ‘b’, ‘c’ or ‘d’.

The device identifier numbers can be found here. |device_identifier_constant|

Trait Implementations

Returns a copy of the value. Read more
Performs copy-assignment from source. Read more

Auto Trait Implementations

Blanket Implementations

Gets the TypeId of self. Read more
Immutably borrows from an owned value. Read more
Mutably borrows from an owned value. Read more

Returns the argument unchanged.

Calls U::from(self).

That is, this conversion is whatever the implementation of From<T> for U chooses to do.

Should always be Self
The resulting type after obtaining ownership.
Creates owned data from borrowed data, usually by cloning. Read more
Uses borrowed data to replace owned data, usually by cloning. Read more
The type returned in the event of a conversion error.
Performs the conversion.
The type returned in the event of a conversion error.
Performs the conversion.