// SPDX-License-Identifier: LicenseRef-PolyForm-Noncommercial-1.0.0
//! Protection equipment data types (IEC 61970-302 Protection package).
//!
//! Stores relay settings, auto-reclose sequences, and synchrocheck parameters
//! parsed from CGMES protection profile data. These are informational/metadata
//! types — they do not affect power flow computation but are preserved for
//! downstream protection coordination tools (e.g., surge-fault TCC analysis).
use serde::{Deserialize, Serialize};
/// Overcurrent relay settings (IEC 61970-302 CurrentRelay).
#[derive(Debug, Clone, Default, Serialize, Deserialize)]
pub struct CurrentRelaySettings {
/// CIM mRID.
pub mrid: String,
/// Relay name.
pub name: String,
/// Phase pickup current (A).
pub phase_pickup_a: Option<f64>,
/// Ground pickup current (A).
pub ground_pickup_a: Option<f64>,
/// Negative-sequence pickup (A).
pub neg_seq_pickup_a: Option<f64>,
/// Phase time dial (s).
pub phase_time_dial_s: Option<f64>,
/// Ground time dial (s).
pub ground_time_dial_s: Option<f64>,
/// Neg-seq time dial (s).
pub neg_seq_time_dial_s: Option<f64>,
/// True = inverse-time characteristic, false = definite-time.
pub inverse_time: bool,
/// Directional element.
pub directional: bool,
/// Bus where CTs are located.
pub bus: Option<u32>,
/// Protected switch/breaker mRID.
pub protected_switch_mrid: Option<String>,
}
/// Distance relay settings (IEC 61970-302 DistanceRelay / zones).
#[derive(Debug, Clone, Default, Serialize, Deserialize)]
pub struct DistanceRelaySettings {
/// CIM mRID.
pub mrid: String,
/// Relay name.
pub name: String,
/// Forward reach (Ohm).
pub forward_reach_ohm: Option<f64>,
/// Forward blind reach (Ohm).
pub forward_blind_ohm: Option<f64>,
/// Backward/reverse reach (Ohm).
pub backward_reach_ohm: Option<f64>,
/// Backward blind reach (Ohm).
pub backward_blind_ohm: Option<f64>,
/// MHO characteristic angle (degrees).
pub mho_angle_deg: Option<f64>,
/// Z0/Z1 compensation ratio.
pub zero_seq_rx_ratio: Option<f64>,
/// Zero-sequence forward reach (Ohm).
pub zero_seq_reach_ohm: Option<f64>,
/// Bus where CTs/VTs are located.
pub bus: Option<u32>,
/// Protected switch mRID.
pub protected_switch_mrid: Option<String>,
}
/// A single auto-reclose shot.
#[derive(Debug, Clone, Default, Serialize, Deserialize)]
pub struct RecloseShot {
/// Shot number (1-based).
pub step: u32,
/// Reclose delay (s).
pub delay_s: f64,
}
/// Auto-reclose sequence for a breaker.
#[derive(Debug, Clone, Default, Serialize, Deserialize)]
pub struct RecloseSequenceData {
/// Protected switch/breaker mRID.
pub protected_switch_mrid: String,
/// Ordered reclose shots.
pub shots: Vec<RecloseShot>,
}
/// Synchrocheck relay settings (IEC 61970-302 SynchrocheckRelay).
#[derive(Debug, Clone, Default, Serialize, Deserialize)]
pub struct SynchrocheckSettings {
/// CIM mRID.
pub mrid: String,
/// Relay name.
pub name: String,
/// Maximum angle difference (degrees).
pub max_angle_diff_deg: Option<f64>,
/// Maximum frequency difference (Hz).
pub max_freq_diff_hz: Option<f64>,
/// Maximum voltage magnitude difference (pu).
pub max_volt_diff_pu: Option<f64>,
/// Bus where relay is located.
pub bus: Option<u32>,
/// Protected switch mRID.
pub protected_switch_mrid: Option<String>,
}
/// Container for all protection equipment data.
#[derive(Debug, Clone, Default, Serialize, Deserialize)]
pub struct ProtectionData {
/// Overcurrent relays.
pub current_relays: Vec<CurrentRelaySettings>,
/// Distance/impedance relays.
pub distance_relays: Vec<DistanceRelaySettings>,
/// Auto-reclose sequences.
pub reclose_sequences: Vec<RecloseSequenceData>,
/// Synchrocheck relays.
pub synchrocheck_relays: Vec<SynchrocheckSettings>,
}
impl ProtectionData {
/// Returns true if no protection equipment has been loaded.
pub fn is_empty(&self) -> bool {
self.current_relays.is_empty()
&& self.distance_relays.is_empty()
&& self.reclose_sequences.is_empty()
&& self.synchrocheck_relays.is_empty()
}
}