# Reference models
Every recovery claim rvt-rs makes is measured against Revit's own export of a
real file. This page lists those files, where they come from, what may be
done with them, and what a run of rvt-rs on them should show. The machine
record is the `artifacts` list of
[`research/witness-registry.json`](../research/witness-registry.json): origin,
licence, sha256, byte count, Revit release, how the reference export was
made, and whether the file may be redistributed.
## Get the licensed ones
```bash
tools/fetch-reference-models.sh # into _project_corpus/Revit (gitignored)
RVT_PROJECT_CORPUS_DIR="$(realpath _project_corpus/Revit)" \
cargo test --profile ci --test revit_global_ids --test element_records_2025
```
The script downloads each redistributable file from its original source and
checks it against the registry; nothing is vendored in this repository. It
lists the local-only files with their source and hash, and never fetches them.
## The files
| magnetar Core Interior | 2024 | MIT, redistributable | IFC4 ReferenceView 1.2, Revit 24.0.20.20 (the full `_slim` export, and a 20 KB element fixture) | 360 walls, 132 doors, 6 windows, 256 columns, 80 slabs, 15 storeys; Revit's GlobalId on 854 elements, 116 rooms and 15 storeys. Run in CI. |
| magnetar Einhoven | 2023 | MIT, redistributable | none | 2023 element records with no export to score against (walls, windows, materials), the 2023 arc-wall path; pinned by the project-count fixture and the viewer's browser test |
| IFC-ECS RE1 Architecture, Mechanical, Plumbing, Electrical | 2025 | MIT, redistributable | IFC2X3 CoordinationView 2.0, Revit 26.2.0.20 | 2025 element records; Architecture: 7 walls, 2 slabs, 11 rooms; 2 storeys each; Revit's GlobalIds 73 / 73 / 123 / 12. Run in CI. |
| Autodesk Snowdon Towers Architectural | 2024 | none declared, local only | IFC4 ReferenceView 1.2, Revit 24.0.20.20 | 6,021 exported, 5,945 of them in Revit's export; 1,078 walls; 18 storeys; wall joins, layers, curtain walls, stairs, roofs |
| Autodesk Snowdon Towers Structural | 2024 | none declared, local only | VIM | beams along their axes, structural categories |
| Autodesk Snowdon Towers Plumbing, HVAC, Electrical | 2024 | Autodesk sample, local only; downloaded from Autodesk's "Revit Sample Project Files" page (sha256 `4f80526b…`, `58538599…`, `e50e1b71…`) | VIM (2027 edition) | **held out**: never used to develop the decoder, measured once as they are (`reports/validation/held-out-snowdon-mep-2026-09-27.md`) |
| MIT 4.567 tutorial house, 2024 and 2025 saves | 2024, 2025 | copyright reserved, local only | none | the same model and ElementIds in two releases; the one shed roof |
| 255ribeiro Projeto1, `teste_export_2025` | 2025 | none declared, local only | IFC4X3 CoordinationView; IFC4 DesignTransferView 1.0, Revit 25.4 (PTB) | metric projects; IFC export overrides; files saved in `PTB` (RE-123) |
| 255ribeiro `Exemplo_data`, `modelo_bim` | 2023 | none declared, local only | IFC4 ReferenceView 1.2, Revit 23.1 (`Exemplo_data`); IFC4 DesignTransferView 1.0, Revit 26.2 PTB (`modelo_bim`, exported from the 2023 file by a later Revit) | Revit 2023 element records (RE-81 to RE-122): 37 of 37 and 37 of 45 elements, storeys, types, layers, materials, wall joins, beams; files saved in `PTB` |
## Candidates, not yet measured here
STE1200 (Discussion #112) measured these and gave their provenance; rvt-rs
has not measured them yet. They are public downloads without a stated
redistribution licence, so they would be local-only oracles: fetched from
their source by whoever runs the measurement, never committed.
| AA-SingleDwellingHouse-RVT-CIADD, with its IFC | 2026 | [flowbim.ee](https://flowbim.ee/files/content/cci/ENG/AA-SingleDwellingHouse-RVT-CIADD.rvt) | `eeff78f3…0a654` (IFC `c9e2986c…67342`) | the first 2026 project with Revit's export: the 2026 element-record gate (#421) |
| 02_BIMcollab_Example_STR, with its IFC2X3 | 2015 | the public BIMcollab example project package | `8cd1f122…e193` | the pre-2024 record envelope (#421) |
| rac_basic_sample_project | 2017 | Autodesk sample | `a1d3d077…5fefb` | the same, with no export |
| Geberit VariForm washbasin PRO_1833290, two variants | 2018 family | Geberit | `28b9d111…e5e4`, `0d48b22c…fbb9` | DirectShape meshes in a family |
| Pucciplast Cassetta Eco 9/4 l (EN) | 2022 family | Pucciplast | `a610ffcc…ae00` | sketch forms and voids in a family |
STE1200's test vectors for the first three (record bytes, offsets and the
values read) are the cross-check for any reader of them.
## Compare like with like
The reference exports were made with different settings, and several
differences between rvt-rs and "Revit's export" are settings, not decoding:
- **View definition.** A ReferenceView export (Core Interior, Snowdon) writes
bodies as tessellations and no material layer sets, so layer sets are scored
against the faces its bodies style with each material. A CoordinationView
export (RE1) writes layer sets of its own.
- **Schema.** RE1 is IFC2X3 and Projeto1 IFC4X3; entity names differ from IFC4
(for example `IfcFlowTerminal` in IFC2X3 for what IFC4 types more finely).
- **Coordinates.** Every export here uses shared coordinates. rvt-rs writes
Revit's internal coordinates, so compare after the export's own transform
(Snowdon: rotate 26.0156°, translate (1370151.83, 258247.98) ft, z + 780.5 ft).
- **What is exported.** Revit's exporter leaves out non-primary design
options, elements not in the exported phase, 2D-only families and some
types (#309, #328); rvt-rs follows it where the bytes say which.
- **Model state.** An export can be newer than the `.rvt` beside it:
`teste_export_2025.ifc` shows one wall in a later state than its `.rvt`.
## Adding a model
A new reference model is most useful when its owner can licence it for
redistribution and it comes with Revit's own IFC export. Record it in the
registry's `artifacts` (id, node, sha256, bytes, source, url when fetchable,
licence, Revit release, `derived_from` and `via` for the export, an `export`
line with the view definition and exporter version, `redistributable`, and
the observations you checked) and open a pull request with the entry only.
See [`corpus-intake.md`](corpus-intake.md) for the three intake lanes.
If you cannot share the file, share what rvt-rs says about it:
`rvt-inspect model.rvt --json` (paths are redacted by default) and
`rvt-ifc model.rvt -o /tmp/out.ifc --diagnostics diag.json` (post the
`diag.json`, not the IFC). They hold counts, Revit class and category names,
and a few sample names such as storeys and materials, but no geometry; read
both before posting and remove any name you would not publish.
## Tiny models anyone with Revit can make
Several open questions need a Revit file whose answer is known in advance.
Each recipe is a new project from Revit's default architectural template,
saved in Revit 2024 or 2025, and exported with File > Export > IFC using
"IFC4 Reference View" and default options. Contribute the `.rvt`, the `.ifc`,
and a line saying you release both under MIT or CC0.
1. **Hip roof (#356).** On Level 1, four Basic Wall "Generic - 200mm" walls
forming a 10 m by 6 m rectangle, 3 m high. Roof by Footprint on Level 2,
picking the four walls, every edge "Defines Slope" at 30°, roof type
"Generic - 300mm".
2. **Gable roof (#356).** The same walls; Roof by Footprint with only the two
long edges defining slope at 30°.
3. **Wall joins (#238, #358).** Four "Generic - 200mm" walls: an L corner
(default join), a second L corner with the join set to Miter, a T junction,
and one wall end with "Disallow Join".
4. **Room (#90).** The rectangle of recipe 1 without a roof, one interior
wall splitting it 6 m / 4 m, and a Room placed in each part.
5. **Opening (#227).** One "Generic - 200mm" wall 5 m long with one