rust_ocpp/v1_6/types/measurand.rs
1/// Allowable values of the optional "measurand" field of a Value element, as used in MeterValuesRequest and StopTransaction.req messages. Default value of "measurand" is always "Energy.Active.Import.Register"
2#[derive(serde::Serialize, serde::Deserialize, Debug, Clone, PartialEq, Default)]
3pub enum Measurand {
4 ///Instantaneous current flow from EV
5 #[serde(rename = "Current.Export")]
6 CurrentExport,
7 /// Instantaneous current flow to EV
8 #[serde(rename = "Current.Import")]
9 CurrentImport,
10 /// Maximum current offered to EV
11 #[serde(rename = "Current.Offered")]
12 CurrentOffered,
13 /// Numerical value read from the "active electrical energy" (Wh or kWh) register of the (most authoritative) electrical meter measuring energy exported (to the grid).
14 #[serde(rename = "Energy.Active.Export.Register")]
15 EnergyActiveExportRegister,
16 /// Numerical value read from the "active electrical energy" (Wh or kWh) register of the (most authoritative) electrical meter measuring energy imported (from the grid supply).
17 #[default]
18 #[serde(rename = "Energy.Active.Import.Register")]
19 EnergyActiveImportRegister,
20 /// Numerical value read from the "reactive electrical energy" (VARh or kVARh) register of the (most authoritative) electrical meter measuring energy exported (to the grid).
21 #[serde(rename = "Energy.Reactive.Export.Register")]
22 EnergyReactiveExportRegister,
23 /// Numerical value read from the "reactive electrical energy" (VARh or kVARh) register of the (most authoritative) electrical meter measuring energy imported (from the grid supply).
24 #[serde(rename = "Energy.Reactive.Import.Register")]
25 EnergyReactiveImportRegister,
26 /// Absolute amount of "active electrical energy" (Wh or kWh) exported (to the grid) during an associated time "interval", specified by a Metervalues ReadingContext, and applicable interval duration configuration values (in seconds) for "ClockAlignedDataInterval" and "MeterValueSampleInterval".
27 #[serde(rename = "Energy.Active.Export.Interval")]
28 EnergyActiveExportInterval,
29 /// Absolute amount of "active electrical energy" (Wh or kWh) imported (from the grid supply) during an associated time "interval", specified by a Metervalues ReadingContext, and applicable interval duration configuration values (in seconds) for "ClockAlignedDataInterval" and "MeterValueSampleInterval".
30 #[serde(rename = "Energy.Active.Import.Interval")]
31 EnergyActiveImportInterval,
32 /// Absolute amount of "reactive electrical energy" (VARh or kVARh) exported (to the grid) during an associated time "interval", specified by a Metervalues ReadingContext, and applicable interval duration configuration values (in seconds) for "ClockAlignedDataInterval" and "MeterValueSampleInterval".
33 #[serde(rename = "Energy.Reactive.Export.Interval")]
34 EnergyReactiveExportInterval,
35 /// Absolute amount of "reactive electrical energy" (VARh or kVARh) imported (from the grid supply) during an associated time "interval", specified by a Metervalues ReadingContext, and applicable interval duration configuration values (in seconds) for "ClockAlignedDataInterval" and "MeterValueSampleInterval".
36 #[serde(rename = "Energy.Reactive.Import.Interval")]
37 EnergyReactiveImportInterval,
38 /// Instantaneous reading of powerline frequency. NOTE: OCPP 1.6 does not have a UnitOfMeasure for frequency, the UnitOfMeasure for any SampledValue with measurand: Frequency is Hertz.
39 Frequency,
40 /// Instantaneous active power exported by EV. (W or kW)
41 #[serde(rename = "Power.Active.Export")]
42 PowerActiveExport,
43 /// Instantaneous active power imported by EV. (W or kW)
44 #[serde(rename = "Power.Active.Import")]
45 PowerActiveImport,
46 /// Instantaneous power factor of total energy flow
47 #[serde(rename = "Power.Factor")]
48 PowerFactor,
49 /// Maximum power offered to EV
50 #[serde(rename = "Power.Offered")]
51 PowerOffered,
52 /// Instantaneous reactive power exported by EV. (var or kvar)
53 #[serde(rename = "Power.Reactive.Export")]
54 PowerReactiveExport,
55 /// Instantaneous reactive power imported by EV. (var or kvar)
56 #[serde(rename = "Power.Reactive.Import")]
57 PowerReactiveImport,
58 /// Fan speed in RPM
59 #[serde(rename = "RPM")]
60 Rpm,
61 /// State of charge of charging vehicle in percentage
62 SoC,
63 /// Temperature reading inside Charge Point.
64 Temperature,
65 /// Instantaneous AC RMS supply voltage
66 Voltage,