rinex-cli 0.5.0

Command line tool parse and analyze RINEX data
## RINEX filtering

Two kinds of filtering operations:

* conservative with `--retain`
* exclusive with `--filter`

For example this command will only retain data from specific vehicules

```bash
rinex-cli 
     -f test_resources/OBS/V2/rovn0010.21o \
        --retain-sv R03,G10
``` 

Filtering and resampling operations can be stacked together, for efficient
record stripping:

```bash
rinex-cli --pretty -f test_resources/OBS/V2/rovn0010.21o \
    --decim-interval 00:05:00 \
        --retain-sv G10
```

Filtering and resampling operations are performed whathever the user
requested actions. This allows performing the requested action
on data of interest.

This applies to any known tool mode:

* RINEX identification
* Record analysis
* RINEX processing
* advanced processing..

## Observations / Data filter

Observation and Meteo RINEX are sorted by Observation. 
The user can focus on data of interest with `--retain-obs`,
to which an array of Observation Codes can be passed.

For example, focus on Phase and Pseudo Range observations
in old RINEX format:

```bash
rinex-cli -f test_resources/OBS/V2/zegv0010.21o  --retain-obs C1,L1
```

Navigation RINEX are sorted by orbits. The `--retain-orb` can be used
to focus on orbit fields

```bash
rinex-cli -f test_resources/NAV/V3/CBW100NLD_R_20210010000_01D_MN.rnx \
    --retain-orb cus,omega0 --pretty
```

In any case, a quick RINEX identification helps identify
which Observations exist:

```bash
rinex-cli -f test_resources/OBS/V2/zegv0010.21o  --obs --pretty
rinex-cli -f test_resources/NAV/V3/CBW100NLD_R_20210010000_01D_MN.rnx --orbits --pretty
```

## Signal condition filters

Observation data might have an "LLI" flag attached to them.
It is possible to apply an And() mask on this field. In this case,
all epochs that did not come with an LLI flag get also dropped out.

In this example, we focus on epochs where a `Loss of Lock` event happened

```shell
rinex-cli --pretty --lli-mask 1 --sv R01 \ 
          -f test_resources/OBS/V2/zegv0010.21o
```

SSI field is another data field that might come with an observation
and it gives the estimated receiver power / SNR at the sampling instant.

It is possible to filter data on minimum signal strength, which
is equivalent to a data "quality" filter

With the following command, we only retain data with SSI >= 5
that means at least 30 dB SNR. 

```shell
rinex-cli --pretty -f test_resources/OBS/V2/zegv0010.21o \
        --ssi-filter 5 --sv-filter R01
```