Skip to main content

opcua_kit/client/
meter.rs

1use time::OffsetDateTime;
2
3use super::sample::Quality;
4use super::{
5    Client, EngineeringUnitEvidence, ReadAttribute, ReadError, Sample, UnitStage,
6    VariableDefinition, ua,
7};
8use crate::commissioning::{
9    Contract, Error, Outcome, SignalRequirement,
10    meter::{MeterReading, meter_signal},
11};
12
13/// A reviewed meter could not be verified or its DataValue could not be recorded exactly.
14#[derive(Debug, thiserror::Error)]
15#[non_exhaustive]
16pub enum MeterReadError {
17    /// The supplied contract is outside the supported single-register profile.
18    #[error("invalid meter contract: {0}")]
19    Contract(#[source] Error),
20    /// The reviewed user differs from the authenticated session user.
21    #[error("meter principal differs from the authenticated session")]
22    Principal,
23    /// The contract selects a different server from the pinned client.
24    #[error("meter contract ApplicationUri differs from the pinned server")]
25    ServerIdentity,
26    /// A service, session, node resolution or attribute decoding failed.
27    #[error(transparent)]
28    Read(#[from] ReadError),
29    /// Required metadata was missing, different, or lacked an unqualified Good status.
30    #[error("meter {attribute:?}: {outcome:?} (status 0x{status:08X})")]
31    Definition {
32        /// Mismatch for a confirmed contradiction, Unverified for incomplete evidence.
33        outcome: Outcome,
34        /// The attribute that failed the gate.
35        attribute: ReadAttribute,
36        /// Original server operation status.
37        status: u32,
38    },
39    /// The verified standard property did not confirm watt-hours with status zero.
40    #[error("meter engineering units at {stage:?}: {outcome:?} (status 0x{status:08X})")]
41    Units {
42        /// Mismatch for a confirmed different unit, Unverified for incomplete evidence.
43        outcome: Outcome,
44        /// Where the independent property lookup stopped.
45        stage: UnitStage,
46        /// Original operation status at that stage.
47        status: u32,
48    },
49    /// A Good-severity Value response omitted the register payload.
50    #[error("Good meter DataValue has no scalar payload")]
51    MissingValue,
52    /// A clock cannot be represented in the meter document without losing information.
53    #[error("meter {clock} is outside the supported UTC range or precision")]
54    InvalidTimestamp {
55        /// Name of the clock field in the evidence document.
56        clock: &'static str,
57    },
58    /// The resulting document failed the commissioning evidence validator or size limit.
59    #[error("invalid meter evidence: {0}")]
60    Evidence(#[source] Error),
61}
62
63fn require<T: PartialEq>(
64    attribute: ReadAttribute,
65    observed: Sample<T>,
66    expected: &T,
67) -> Result<(), MeterReadError> {
68    match observed.value {
69        Some(value) if observed.status == 0 && value == *expected => Ok(()),
70        value => Err(MeterReadError::Definition {
71            attribute,
72            status: observed.status,
73            outcome: if observed.status == 0 && value.is_some() {
74                Outcome::Mismatch
75            } else {
76                Outcome::Unverified
77            },
78        }),
79    }
80}
81
82fn verify_definition(
83    signal: &SignalRequirement,
84    declaration: VariableDefinition,
85) -> Result<(), MeterReadError> {
86    require(
87        ReadAttribute::DataType,
88        declaration.data_type?,
89        &signal.data_type,
90    )?;
91    require(ReadAttribute::ValueRank, declaration.value_rank?, &-1)
92}
93
94fn verify_units(evidence: EngineeringUnitEvidence) -> Result<(), MeterReadError> {
95    let unit = evidence.sample.value.filter(|unit| {
96        evidence.stage == UnitStage::Value && evidence.sample.status == 0 && unit.is_identified()
97    });
98    match unit {
99        Some(unit) if unit.is_watt_hour() => Ok(()),
100        other => Err(MeterReadError::Units {
101            stage: evidence.stage,
102            status: evidence.sample.status,
103            outcome: if other.is_some() {
104                Outcome::Mismatch
105            } else {
106                Outcome::Unverified
107            },
108        }),
109    }
110}
111
112impl Client {
113    /// Read one approved import register as a serializable commissioning meter reading.
114    ///
115    /// Each call checks the pinned server, the register's DataType and scalar rank, and
116    /// its independently resolved watt-hour property before requesting the process Value.
117    /// The caller supplies and reviews the site's register identity and import direction.
118    ///
119    /// ```
120    /// # async fn poll(client: &opcua_kit::Client, contract: &opcua_kit::commissioning::Contract)
121    /// # -> Result<(), Box<dyn std::error::Error>> {
122    /// let reading = client.read_meter(contract).await?;
123    /// let json = serde_json::to_string(&reading)?;
124    /// println!("{json}");
125    /// # Ok(()) }
126    /// ```
127    pub async fn read_meter(&self, contract: &Contract) -> Result<MeterReading, MeterReadError> {
128        let signal = meter_signal(contract).map_err(MeterReadError::Contract)?;
129        if contract.principal() != self.principal {
130            return Err(MeterReadError::Principal);
131        }
132        if contract.application_uri() != self.server_uri {
133            return Err(MeterReadError::ServerIdentity);
134        }
135        let (mut session, metadata) = self.read_session().await?;
136        let definition = self
137            .definition_locked(&mut session, metadata, &signal.node, Quality::ExactGood)
138            .await?;
139        verify_definition(signal, definition)?;
140        let units = self
141            .units_locked(
142                &mut session,
143                &metadata.namespaces,
144                &signal.node,
145                Quality::ExactGood,
146                |_| true,
147            )
148            .await?;
149        verify_units(units)?;
150        let wire = metadata.namespaces.wire_node(&signal.node, 0)?;
151        let raw = self
152            .one_attribute(&mut session, wire, ua::AttributeId::Value)
153            .await?;
154        let received_at = OffsetDateTime::now_utc();
155        drop(session);
156        MeterReading::from_live(contract, signal, &raw, received_at)
157    }
158}
159
160#[cfg(test)]
161mod tests {
162    use super::*;
163    use crate::EngineeringUnit;
164
165    fn sample<T>(status: u32, value: Option<T>) -> Sample<T> {
166        Sample {
167            status,
168            value,
169            source_timestamp: None,
170            server_timestamp: None,
171        }
172    }
173
174    #[test]
175    fn exact_good_metadata_distinguishes_contradiction_from_unavailable_evidence() {
176        for (status, rank, expected) in [
177            (0, Some(-1), None),
178            (0, Some(1), Some(Outcome::Mismatch)),
179            (0, None, Some(Outcome::Unverified)),
180            (1, Some(-1), Some(Outcome::Unverified)),
181            (1, Some(1), Some(Outcome::Unverified)),
182        ] {
183            let outcome = match require(ReadAttribute::ValueRank, sample(status, rank), &-1) {
184                Ok(()) => None,
185                Err(MeterReadError::Definition {
186                    attribute: ReadAttribute::ValueRank,
187                    status: observed,
188                    outcome,
189                }) => {
190                    assert_eq!(observed, status);
191                    Some(outcome)
192                }
193                Err(error) => panic!("{error}"),
194            };
195            assert_eq!(outcome, expected);
196        }
197        let wh = EngineeringUnit {
198            namespace_uri: "http://www.opcfoundation.org/UA/units/un/cefact".into(),
199            unit_id: 0x574852,
200        };
201        let other = EngineeringUnit {
202            namespace_uri: "urn:vendor".into(),
203            unit_id: wh.unit_id,
204        };
205        let unknown = EngineeringUnit {
206            namespace_uri: "urn:vendor".into(),
207            unit_id: -1,
208        };
209        for (stage, status, unit, expected) in [
210            (UnitStage::Value, 0, Some(wh.clone()), None),
211            (UnitStage::Value, 0, Some(other), Some(Outcome::Mismatch)),
212            (
213                UnitStage::Value,
214                0,
215                Some(unknown),
216                Some(Outcome::Unverified),
217            ),
218            (UnitStage::Value, 0, None, Some(Outcome::Unverified)),
219            (UnitStage::Value, 1, Some(wh), Some(Outcome::Unverified)),
220            (UnitStage::Browse, 0, None, Some(Outcome::Unverified)),
221        ] {
222            let evidence = EngineeringUnitEvidence {
223                stage,
224                property: None,
225                sample: sample(status, unit),
226            };
227            let outcome = match verify_units(evidence) {
228                Ok(()) => None,
229                Err(MeterReadError::Units {
230                    stage: observed_stage,
231                    status: observed_status,
232                    outcome,
233                }) => {
234                    assert_eq!((observed_stage, observed_status), (stage, status));
235                    Some(outcome)
236                }
237                Err(error) => panic!("{error}"),
238            };
239            assert_eq!(outcome, expected);