opcua-kit 0.2.0

Embeddable OPC UA client, server and UADP library for Rust applications
Documentation
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
//! Evidence for one approved cumulative grid-import register and its CEMS trace.
//!
//! A metadata snapshot contains no register values. Select a single scalar
//! UInt32, UInt64, Float or Double in watt-hours and use a separate meter reading document.
//! The site must confirm import direction and the source clock's meaning.
//! Projection preserves observed instants and never invents a quarter boundary.
//!
//! Good-severity evidence carries an unsigned register in `value`, or the raw
//! floating-point word in `valueBits`. A Float word is a JSON UInt32. A Double
//! word is a string of 16 lowercase hex digits, most significant digit first.
//! Floating-point readings qualify as whole Wh only in `[0, 2²⁴)` for Float
//! and `[0, 2⁵³)` for Double, under the same status and timestamp rules.

use std::{fmt, marker::PhantomData};

use serde::{Deserialize, Deserializer, Serialize, Serializer, de};

pub use time::OffsetDateTime;
use time::{Duration, UtcOffset, format_description::well_known::Rfc3339};

use super::{ByteBudget, Contract, Error, Expected, MAX_DOCUMENT_BYTES, NodeId, Unit, present};
use crate::{Severity, status_severity};

const UA: &str = "http://opcfoundation.org/UA/";

#[cfg(feature = "client")]
mod live;

mod projection;
pub use projection::{MeterProjector, MeterWindow, project_meter_trace};

pub(crate) fn meter_signal(contract: &Contract) -> Result<&Expected, Error> {
    if contract.0.principal != "anonymous"
        && !contract
            .0
            .principal
            .strip_prefix("username:")
            .is_some_and(|name| !name.trim().is_empty() && name.len() <= 256)
    {
        return Err(Error::new(
            "expected anonymous or username:<account> for the meter principal",
        ));
    }
    let [signal] = contract.0.signals.as_slice() else {
        return Err(Error::new(
            "meter contract must select exactly one grid-import register",
        ));
    };
    if signal.data_type.namespace() != UA
        || !matches!(
            signal.data_type.identifier(),
            "i=7" | "i=9" | "i=10" | "i=11"
        )
    {
        return Err(Error::new(
            "meter contract requires standard UInt32, UInt64, Float or Double DataType",
        ));
    }
    if signal.value_rank != Some(-1) {
        return Err(Error::new("meter contract requires scalar valueRank -1"));
    }
    if !signal
        .engineering_units
        .as_ref()
        .is_some_and(Unit::is_watt_hour)
    {
        return Err(Error::new(
            "meter contract requires UN/CEFACT watt-hours (WHR)",
        ));
    }
    Ok(signal)
}

/// Check that a reviewed contract selects exactly one supported grid-import register.
pub fn validate_meter_contract(contract: &Contract) -> Result<(), Error> {
    meter_signal(contract).map(|_| ())
}

#[derive(Clone, Copy, Debug, Eq, PartialEq, Ord, PartialOrd)]
struct Instant(OffsetDateTime);

impl Instant {
    fn utc(time: OffsetDateTime) -> Option<Self> {
        time.checked_to_offset(UtcOffset::UTC)
            .filter(|utc| (0..=9999).contains(&utc.year()))
            .map(Self)
    }

    fn aligned(self) -> bool {
        self.0.nanosecond() == 0 && self.0.unix_timestamp().rem_euclid(900) == 0
    }
}

impl<'de> Deserialize<'de> for Instant {
    fn deserialize<D: Deserializer<'de>>(deserializer: D) -> Result<Self, D::Error> {
        let text = String::deserialize(deserializer)?;
        let bytes = text.as_bytes();
        // RFC 3339 parsers can normalize leap seconds and truncate subseconds.
        // Reject either before parsing so distinct evidence cannot collapse.
        let excess_precision = bytes.get(19) == Some(&b'.')
            && bytes
                .get(20..30)
                .is_some_and(|digits| digits.iter().all(u8::is_ascii_digit));
        if excess_precision
            || bytes.get(17..19) == Some(b"60")
            || !matches!(bytes.get(10), Some(b'T' | b't'))
            || text.ends_with("-00:00")
        {
            return Err(de::Error::custom(
                "expected RFC 3339 with known offset and at most nanosecond precision",
            ));
        }
        let local = OffsetDateTime::parse(&text, &Rfc3339)
            .map_err(|_| de::Error::custom("invalid RFC 3339 timestamp"))?;
        Self::utc(local)
            .ok_or_else(|| de::Error::custom("timestamp outside four-digit UTC year range"))
    }
}

impl Serialize for Instant {
    fn serialize<S: Serializer>(&self, serializer: S) -> Result<S::Ok, S::Error> {
        let text = self.0.format(&Rfc3339).map_err(serde::ser::Error::custom)?;
        serializer.serialize_str(&text)
    }
}

/// One scope-checked DataValue. Serialize this to retain its independent clocks,
/// raw UInt32 status, and the original integer or floating-point bit pattern on Good severity.
#[derive(Debug, Serialize)]
#[serde(transparent)]
pub struct MeterReading {
    row: Reading,
    #[serde(skip)]
    line_bytes: usize,
}

// The wire parser and native reader validate the same evidence representation.
#[derive(Debug, Serialize, Deserialize)]
#[serde(rename_all = "camelCase", deny_unknown_fields)]
struct Reading {
    schema_version: u32,
    device: String,
    application_uri: String,
    principal: String,
    name: String,
    #[serde(deserialize_with = "object")]
    node: NodeId,
    #[serde(deserialize_with = "object")]
    data_type: NodeId,
    value_rank: i32,
    #[serde(deserialize_with = "object")]
    engineering_units: Unit,
    received_at: Instant,
    // An explicit null records that a server did not return this clock.
    #[serde(deserialize_with = "Option::deserialize")]
    source_at: Option<Instant>,
    #[serde(deserialize_with = "Option::deserialize")]
    server_at: Option<Instant>,
    status: u32,
    #[serde(
        default,
        skip_serializing_if = "Option::is_none",
        deserialize_with = "present"
    )]
    value: Option<u64>,
    #[serde(
        default,
        skip_serializing_if = "Option::is_none",
        deserialize_with = "present"
    )]
    value_bits: Option<FloatingBits>,
}

// A 32-bit word is exactly representable by JSON consumers using binary64.
// A 64-bit word uses hexadecimal text so even its least significant bit survives.
#[derive(Clone, Copy, Debug, Eq, PartialEq)]
enum FloatingBits {
    Float(u32),
    Double(u64),
}

impl<'de> Deserialize<'de> for FloatingBits {
    fn deserialize<D: Deserializer<'de>>(d: D) -> Result<Self, D::Error> {
        struct Word;
        impl de::Visitor<'_> for Word {
            type Value = FloatingBits;

            fn expecting(&self, f: &mut fmt::Formatter<'_>) -> fmt::Result {
                f.write_str("UInt32 or 16 lowercase hexadecimal digits")
            }

            fn visit_u64<E: de::Error>(self, word: u64) -> Result<Self::Value, E> {
                u32::try_from(word)
                    .map(FloatingBits::Float)
                    .map_err(E::custom)
            }

            fn visit_str<E: de::Error>(self, word: &str) -> Result<Self::Value, E> {
                if word.len() != 16 || !word.bytes().all(|b| matches!(b, b'0'..=b'9' | b'a'..=b'f'))
                {
                    return Err(E::custom("expected 16 lowercase hexadecimal digits"));
                }
                u64::from_str_radix(word, 16)
                    .map(FloatingBits::Double)
                    .map_err(E::custom)
            }
        }
        // Restrict the JSON token to a scalar before constructing any payload.
        d.deserialize_any(Word)
    }
}

impl Serialize for FloatingBits {
    fn serialize<S: Serializer>(&self, s: S) -> Result<S::Ok, S::Error> {
        match self {
            Self::Float(bits) => s.serialize_u32(*bits),
            Self::Double(bits) => s.collect_str(&format_args!("{bits:016x}")),
        }
    }
}

impl FloatingBits {
    fn whole_wh(self) -> Result<u64, MeterExclusionReason> {
        // Widening a binary32 is exact. Each cutoff is the first magnitude at
        // which the next larger value of its original wire type is 2 Wh away.
        let (wh, limit) = match self {
            Self::Float(bits) => (f64::from(f32::from_bits(bits)), 16_777_216.0),
            Self::Double(bits) => (f64::from_bits(bits), 9_007_199_254_740_992.0),
        };
        if !wh.is_finite() {
            Err(MeterExclusionReason::NonFiniteWh)
        } else if wh < 0.0 {
            Err(MeterExclusionReason::NegativeWh)
        } else if wh >= limit {
            Err(MeterExclusionReason::InsufficientResolution)
        } else if wh.fract() != 0.0 {
            Err(MeterExclusionReason::FractionalWh)
        } else {
            Ok(wh as u64)
        }
    }
}

impl MeterReading {
    fn checked(contract: &Contract, signal: &Expected, row: Reading) -> Result<Self, Error> {
        validate_reading(contract, signal, &row)?;
        let line_bytes = compact_line_bytes(&row)?;
        Ok(Self { row, line_bytes })
    }

    /// Cached byte size of this compact UTF-8 JSON reading plus one LF.
    /// This is the exact input charge for [`MeterProjector::push`].
    pub fn compact_line_bytes(&self) -> usize {
        self.line_bytes
    }

    /// Full OPC UA Value read status, including subcode and information bits.
    pub fn status(&self) -> u32 {
        self.row.status
    }

    /// Original UInt32 or UInt64 register value when the wire status has Good severity.
    pub fn value(&self) -> Option<u64> {
        self.row.value
    }

    /// Original binary32 bits for a Float register when the wire status has Good severity.
    pub fn value_bits(&self) -> Option<u32> {
        match self.row.value_bits {
            Some(FloatingBits::Float(bits)) => Some(bits),
            _ => None,
        }
    }

    /// Original binary64 bits for a Double register when the wire status has Good severity.
    pub fn double_bits(&self) -> Option<u64> {
        match self.row.value_bits {
            Some(FloatingBits::Double(bits)) => Some(bits),
            _ => None,
        }
    }

    /// Original source clock, normalized to UTC at its supplied precision.
    pub fn source_at(&self) -> Option<OffsetDateTime> {
        self.row.source_at.map(|at| at.0)
    }

    /// Original server clock when the read included it.
    pub fn server_at(&self) -> Option<OffsetDateTime> {
        self.row.server_at.map(|at| at.0)
    }

    /// UTC receipt time measured by the reader.
    pub fn received_at(&self) -> OffsetDateTime {
        self.row.received_at.0
    }
}

// serde's default derived struct decoder also accepts positional JSON arrays.
// The document contracts use named object members, including on nested points.
fn object<'de, D: Deserializer<'de>, T: Deserialize<'de>>(d: D) -> Result<T, D::Error> {
    struct Named<T>(PhantomData<T>);
    impl<'de, T: Deserialize<'de>> de::Visitor<'de> for Named<T> {
        type Value = T;
        fn expecting(&self, f: &mut fmt::Formatter<'_>) -> fmt::Result {
            f.write_str("a JSON object")
        }
        fn visit_map<A: de::MapAccess<'de>>(self, map: A) -> Result<T, A::Error> {
            T::deserialize(de::value::MapAccessDeserializer::new(map))
        }
    }
    d.deserialize_map(Named(PhantomData))
}

#[derive(Deserialize)]
#[serde(transparent, bound(deserialize = "T: Deserialize<'de>"))]
struct JsonObject<T>(#[serde(deserialize_with = "object")] T);

fn decode<T: de::DeserializeOwned>(bytes: &[u8], kind: &str) -> Result<T, Error> {
    if bytes.len() > MAX_DOCUMENT_BYTES {
        return Err(Error::new(format!("{kind} exceeds 4 MiB")));
    }
    // Parser diagnostics can quote an entire register value or an unknown key.
    serde_json::from_slice::<JsonObject<T>>(bytes)
        .map(|wrapped| wrapped.0)
        .map_err(|e| {
            Error::new(format!(
                "invalid {kind} at line {}, column {}: check required fields, types and timestamps",
                e.line(),
                e.column()
            ))
        })
}

fn validate_reading(
    contract: &Contract,
    signal: &Expected,
    reading: &Reading,
) -> Result<(), Error> {
    if reading.schema_version != 1 {
        return Err(Error::new(
            "unsupported meter reading schemaVersion (expected 1)",
        ));
    }
    if reading.device != contract.0.device
        || reading.application_uri != contract.0.application_uri
        || reading.principal != contract.0.principal
        || reading.name != signal.name
        || reading.node != signal.node
    {
        return Err(Error::new(
            "meter reading scope or register identity differs from the contract",
        ));
    }
    if reading.data_type != signal.data_type
        || Some(reading.value_rank) != signal.value_rank
        || Some(&reading.engineering_units) != signal.engineering_units.as_ref()
    {
        return Err(Error::new(
            "meter reading DataType, ValueRank or EngineeringUnits differs from the contract",
        ));
    }
    let valid_payload = match status_severity(reading.status) {
        Severity::Good => match signal.data_type.identifier() {
            "i=10" => {
                reading.value.is_none()
                    && matches!(reading.value_bits, Some(FloatingBits::Float(_)))
            }
            "i=11" => {
                reading.value.is_none()
                    && matches!(reading.value_bits, Some(FloatingBits::Double(_)))
            }
            _ => reading.value.is_some() && reading.value_bits.is_none(),
        },
        _ => reading.value.is_none() && reading.value_bits.is_none(),
    };
    if !valid_payload {
        return Err(Error::new(
            "Good integer readings require value, Float requires UInt32 valueBits, and Double requires 16 lowercase hex digits in valueBits. Other severities omit both fields",
        ));
    }
    if signal.data_type.identifier() == "i=7"
        && reading.value.is_some_and(|v| v > u64::from(u32::MAX))
    {
        return Err(Error::new(
            "meter reading value exceeds the approved UInt32 DataType",
        ));
    }
    Ok(())
}

// Check the encoded document including room for its NDJSON delimiter.
fn compact_line_bytes(document: &impl Serialize) -> Result<usize, Error> {
    let mut budget = ByteBudget(MAX_DOCUMENT_BYTES - 1);
    serde_json::to_writer(&mut budget, document).map_err(|error| {
        if error.is_io() {
            Error::new("encoded meter document and newline exceed 4 MiB")
        } else {
            Error::new("could not encode meter document")
        }
    })?;
    Ok(MAX_DOCUMENT_BYTES - budget.0)
}

/// Parse one strict reading and verify it belongs to the reviewed meter contract.
pub fn parse_meter_reading(contract: &Contract, bytes: &[u8]) -> Result<MeterReading, Error> {
    MeterReading::checked(
        contract,
        meter_signal(contract)?,
        decode(bytes, "meter reading")?,
    )
}

/// A UTC instant and an exact watt-hour amount in the CEMS trace.
#[derive(Debug, Serialize, Deserialize)]
#[serde(deny_unknown_fields)]
pub struct MeterPoint {
    at: Instant,
    /// Cumulative register or independently closed interval energy, in watt-hours.
    pub wh: u64,
}

impl MeterPoint {
    /// UTC source instant for a register reading, or start instant of a close.
    pub fn at(&self) -> OffsetDateTime {
        self.at.0
    }
}

// The site maps the independent close feed to the commissioned register.
// This binding is checked locally and omitted from the consumer's trace.
#[derive(Deserialize)]
#[serde(rename_all = "camelCase", deny_unknown_fields)]
struct WindowMeter {
    device: String,
    application_uri: String,
    #[serde(deserialize_with = "object")]
    node: NodeId,
}

#[derive(Deserialize)]
#[serde(deny_unknown_fields)]
struct Window {
    #[serde(deserialize_with = "object")]
    meter: WindowMeter,
    start: Instant,
    end: Instant,
    tolerance_wh: u64,
    closed: Vec<JsonObject<MeterPoint>>,
}

/// A ready-to-serialize input to `cemsd reconcile`. Reconciliation itself
/// remains with CEMS, including its handling of counter decreases and gaps.
#[derive(Debug, Serialize)]
pub struct MeterTrace {
    start: Instant,
    end: Instant,
    tolerance_wh: u64,
    /// Usable source observations, ordered by UTC instant.
    pub register: Vec<MeterPoint>,
    /// Independent closes keyed by the start of the UTC quarter.
    pub closed: Vec<MeterPoint>,
}

impl MeterTrace {
    /// Inclusive start of the comparison window, normalized to UTC.
    pub fn start(&self) -> OffsetDateTime {
        self.start.0
    }

    /// Inclusive end of register coverage, normalized to UTC. Closes must start before this instant.
    pub fn end(&self) -> OffsetDateTime {
        self.end.0
    }

    /// Largest accepted absolute difference between the two energy series, in Wh.
    pub fn tolerance_wh(&self) -> u64 {
        self.tolerance_wh
    }
}

/// Why an observation failed to qualify as a register point.
#[derive(Clone, Copy, Debug, Eq, PartialEq)]
#[non_exhaustive]
pub enum MeterExclusionReason {
    /// Nonzero OPC UA StatusCode, including all qualifier and information bits.
    Status(u32),
    /// The meter supplied no source timestamp.
    MissingSourceTime,
    /// The source instant is later than local receipt.
    SourceAfterReceipt,
    /// The floating-point register contains NaN or infinity.
    NonFiniteWh,
    /// The cumulative register is finite and below zero.
    NegativeWh,
    /// The nonnegative register contains a fraction of a watt-hour.
    FractionalWh,
    /// The next larger value in the register's wire type is more than 1 Wh away.
    InsufficientResolution,
}

impl fmt::Display for MeterExclusionReason {
    fn fmt(&self, f: &mut fmt::Formatter<'_>) -> fmt::Result {
        match self {
            Self::Status(code) => write!(f, "OPC UA status 0x{code:08X}"),
            Self::MissingSourceTime => f.write_str("missing source timestamp"),
            Self::SourceAfterReceipt => f.write_str("source timestamp is after receipt"),
            Self::NonFiniteWh => f.write_str("non-finite register value"),
            Self::NegativeWh => f.write_str("negative cumulative Wh"),
            Self::FractionalWh => f.write_str("fractional Wh"),
            Self::InsufficientResolution => f.write_str("register cannot resolve 1 Wh increments"),
        }
    }
}

/// Location and cause of a single rejected observation.
#[derive(Clone, Copy, Debug, Eq, PartialEq)]
pub struct MeterExclusion {
    /// One-based NDJSON line number (including blank lines), or one-based push number.
    pub input_position: usize,
    /// Meter source time in UTC, when supplied.
    pub source_at: Option<OffsetDateTime>,
    /// The first failed eligibility check for this observation.
    pub reason: MeterExclusionReason,
}

/// Result of projecting evidence into a CEMS trace.
#[derive(Debug)]
pub struct MeterProjection {
    /// Write this compactly as one JSON document for CEMS.
    pub trace: MeterTrace,
    /// Rows with a nonzero status, including qualified Good statuses.
    pub skipped_status: usize,
    /// Unqualified Good rows with missing source time or source time after receipt.
    pub skipped_source_time: usize,
    /// Otherwise eligible Float or Double rows without a nonnegative whole Wh
    /// value below the original type's 1 Wh resolution limit (2²⁴ or 2⁵³).
    pub skipped_precision: usize,
    /// First observation in input order counted by any of the three `skipped_*` counters.
    /// Outside-window observations and usable duplicates do not set this field.
    pub first_exclusion: Option<MeterExclusion>,
    /// Timed rows outside the requested window (regardless of status).
    pub outside_window: usize,
    /// Additional usable rows with the same source instant and exact value.