1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
use serde::{Deserialize, Serialize};
use strum_macros::{AsRefStr, EnumString};
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum AvailabilityType {
/// Charge point is not available for charging.
Inoperative,
/// Charge point is available for charging.
#[default]
Operative,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum CertificateUse {
#[default]
CentralSystemRootCertificate,
ManufacturerRootCertificate,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default, EnumString)]
pub enum ChargePointErrorCode {
/// Failure to lock or unlock connector.
ConnectorLockFailure,
/// Communication failure with the vehicle, might be Mode 3 or other communication protocol problem.\\
/// This is not a real error in the sense that the Charge Point doesn’t need to go to the faulted state. Instead, it should go to the `SuspendedEVSE` state.
EVCommunicationError,
/// Ground fault circuit interrupter has been activated.
GroundFailure,
/// Temperature inside Charge Point is too high.
HighTemperature,
/// Error in internal hard- or software component.
InternalError,
/// The authorization information received from the Central System is in conflict with the `LocalAuthorizationList`.
LocalListConflict,
/// No error to report.
#[default]
NoError,
/// Other type of error. More information in vendorErrorCode.
OtherError,
/// Over current protection device has tripped.
OverCurrentFailure,
/// Voltage has risen above an acceptable level.
OverVoltage,
/// Failure to read electrical/energy/power meter.
PowerMeterFailure,
/// Failure to control power switch.
PowerSwitchFailure,
/// Failure with idTag reader.
ReaderFailure,
/// Unable to perform a reset.
ResetFailure,
/// Voltage has dropped below an acceptable level.
UnderVoltage,
/// Wireless communication device reports a weak signal.
WeakSignal,
}
#[derive(AsRefStr, EnumString, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum ChargePointStatus {
/// When a Connector becomes available for a new user (Operative)
#[default]
Available,
/// When a Connector becomes no longer available for a new user but there is no ongoing Transaction (yet).\\
/// Typically a Connector is in preparing state when a user presents a tag, inserts a cable or a vehicle occupies the parking bay 6 (Operative)
Preparing,
/// When the contactor of a Connector closes, allowing the vehicle to charge (Operative)
Charging,
/// When the EV is connected to the EVSE but the EVSE is not offering energy to the EV, e.g. due to a smart charging restriction,\\
/// local supply power constraints, or as the result of StartTransaction.conf indicating that charging is not allowed etc. (Operative)
SuspendedEVSE,
/// When the EV is connected to the EVSE and the EVSE is offering energy but the EV is not taking any energy. (Operative)
SuspendedEV,
/// When a Transaction has stopped at a Connector, but the Connector is not yet available for a new user, e.g. the cable has not been removed or the vehicle has not left the parking bay (Operative)
Finishing,
/// When a Connector becomes reserved as a result of a Reserve Now command (Operative)
Reserved,
/// When a Connector becomes unavailable as the result of a Change Availability command or an event upon which the Charge Point transitions to unavailable at its discretion.\\
/// Upon receipt of a Change Availability command, the status MAY change immediately or the change MAY be scheduled.\\
/// When scheduled, the Status Notification shall be send when the availability change becomes effective (Inoperative).
Unavailable,
/// When a Charge Point or connector has reported an error and is not available for energy delivery, (Inoperative)
Faulted,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum ChargingProfileKindType {
/// Schedule periods are relative to a fixed point in time defined in the schedule.
#[default]
Absolute,
/// The schedule restarts periodically at the first schedule period.
Recurring,
/// Schedule periods are relative to a situation-specific start point (such as the start of a Transaction) that is determined by the charge point.
Relative,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum ChargingProfilePurposeType {
/// Configuration for the maximum power or current available for an entire Charge Point.
#[default]
ChargePointMaxProfile,
/// Default profile *that can be configured in the Charge Point.\\
/// When a new transaction is started, this profile SHALL be used, unless it was a transaction that was started by a RemoteStartTransaction.req with a `ChargeProfile` that is accepted by the Charge Point.
TxDefaultProfile,
/// Profile with constraints to be imposed by the Charge Point on the current transaction, or on a new transaction when this is started via a RemoteStartTransaction.req with a `ChargeProfile`.\\
/// A profile with this purpose SHALL cease to be valid when the transaction terminates.
TxProfile,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum ChargingRateUnitType {
#[default]
W,
A,
}
#[derive(Debug, PartialEq, Eq)]
pub enum CiStringType {
CiString20 = 20,
CiString25 = 25,
CiString50 = 50,
CiString255 = 255,
CiString500 = 500,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone)]
pub enum ConfigurationKey {
AllowOfflineTxForUnknownId,
AuthorizationCacheEnabled,
AuthorizeRemoteTxRequests,
BlinkRepeat,
ClockAlignedDataInterval,
ConnectionTimeOut,
ConnectorPhaseRotation,
ConnectorPhaseRotationMaxLength,
GetConfigurationMaxKeys,
HeartbeatInterval,
LightIntensity,
LocalAuthorizeOffline,
LocalPreAuthorize,
MaxEnergyOnInvalidId,
MeterValuesAlignedData,
MeterValuesAlignedDataMaxLength,
MeterValuesSampledData,
MeterValuesSampledDataMaxLength,
MeterValueSampleInterval,
MinimumStatusDuration,
NumberOfConnectors,
ResetRetries,
StopTransactionOnEVSideDisconnect,
StopTransactionOnInvalidId,
StopTxnAlignedData,
StopTxnAlignedDataMaxLength,
StopTxnSampledData,
StopTxnSampledDataMaxLength,
SupportedFeatureProfiles,
SupportedFeatureProfilesMaxLength,
TransactionMessageAttempts,
TransactionMessageRetryInterval,
UnlockConnectorOnEVSideDisconnect,
WebSocketPingInterval,
LocalAuthListEnabled,
LocalAuthListMaxLength,
SendLocalListMaxLength,
ReserveConnectorZeroSupported,
ChargeProfileMaxStackLevel,
ChargingScheduleAllowedChargingRateUnit,
ChargingScheduleMaxPeriods,
ConnectorSwitch3to1PhaseSupported,
MaxChargingProfilesInstalled,
CentralContractValidationAllowed,
CertificateSignedMaxChainSize,
CertSigningWaitMinimum,
CertSigningRepeatTimes,
CertificateStoreMaxLength,
ContractValidationOffline,
ISO15118PnCEnabled,
AdditionalRootCertificateCheck,
AuthorizationKey,
CpoName,
SecurityProfile,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum DiagnosticsStatus {
/// Charge Point is not performing diagnostics related tasks. Status Idle SHALL only be used as in a DiagnosticsStatusNotification.req that was triggered by a TriggerMessage.req
#[default]
Idle,
/// Diagnostics information has been uploaded.
Uploaded,
/// Uploading of diagnostics failed.
UploadFailed,
/// File is being uploaded.
Uploading,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum FirmwareStatus {
/// New firmware has been downloaded by Charge Point.
Downloaded,
/// Charge point failed to download firmware.
DownloadFailed,
/// Firmware is being downloaded.
Downloading,
/// Charge Point is not performing firmware update related tasks. Status Idle SHALL only be used as in a `FirmwareStatusNotificationRequest` that was triggered by a `TriggerMessageRequest`
#[default]
Idle,
/// Installation of new firmware has failed.
InstallationFailed,
/// Firmware is being installed.
Installing,
/// New firmware has successfully been installed in charge point.
Installed,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum ParsedGenericStatus {
/// Request has been accepted and will be executed.
#[default]
Accepted,
/// Request has not been accepted and will not be executed.
Rejected,
/// Used for `AvailabilityStatus`, `CertificateStatus`\\
/// Request has been accepted and will be executed when transaction(s) in progress have finished.
Scheduled,
/// Used for `AuthorizationStatus`\\
/// Identifier has been blocked. Not allowed for charging.
Blocked,
/// Used for `AuthorizationStatus`\\
/// Identifier has expired. Not allowed for charging.
Expired,
/// Used for `AuthorizationStatus`\\
/// Identifier is unknown. Not allowed for charging.
Invalid,
/// Used for `AuthorizationStatus`\\
/// Identifier is already involved in another transaction and multiple transactions are not allowed. (Only relevant for a StartTransaction.req.)
ConcurrentTx,
/// Used for `CertificateStatus`
Failed,
/// Used for `ChargingProfileStatus`\\
/// Charge Point indicates that the request is not supported.
NotSupported,
/// Used for `ClearChargingProfileStatus`, `ConfigurationStatus`\\
/// No Charging Profile(s) were found matching the request.
Unknown,
/// Used for `ConfigurationStatus`\\
/// Configuration key is supported and setting has been changed, but change will be available after reboot (Charge Point will not reboot itself)
RebootRequired,
/// Used for `DataTransferStatus`\\
/// Message could not be interpreted due to unknown messageId string.
UnknownMessageId,
/// Used for `DataTransferStatus`\\
/// Message could not be interpreted due to unknown vendorId string.
UnknownVendorId,
/// Used for `DeleteCertificateStatus`\\
/// Certificate was not found
NotFound,
/// Used for `LogStatus`
AcceptedCanceled,
/// Used for `RegistrationStatus`, `AcceptedCanceled`\\
/// Central System is not yet ready to accept the Charge Point. Central System may send\\
/// messages to retrieve information or prepare the Charge Point.
Pending,
/// Used for `ReservationStatus`\\
/// Reservation has not been made, because connectors or specified connector are in an unavailable state.
Unavailable,
/// Used for `ReservationStatus`\\
/// Reservation has not been made, because connectors or specified connector are in a faulted state.
Faulted,
/// Used for `ReservationStatus`\\
/// Reservation has not been made. All connectors or the specified connector are occupied.
Occupied,
/// Used for `TriggerMessageStatus`\\
/// Requested notification cannot be sent because it is either not implemented or unknown.
NotImplemented,
/// Used for `UpdateFirmwareStatus`
InvalidCertificate,
/// Used for `UpdateFirmwareStatus`
RevokedCertificate,
/// Used for `UpdateStatus`\\
/// Version number in the request for a differential update is less or equal then version number of current list.
VersionMismatch,
// Used for unlock connector
/// # From OCPP Specification
/// Connector has successfully been unlocked.
Unlocked,
// Used for unlock connector
/// # From OCPP Specification
/// Failed to unlock the connector: The Charge Point has tried to unlock the connector and has\\
/// detected that the connector is still locked or the unlock mechanism failed.
UnlockFailed,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone)]
pub enum HashAlgorithm {
SHA256,
SHA384,
SHA512,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum Location {
/// Measurement inside body of Charge Point (e.g. Temperature)
#[default]
Body,
///Measurement taken from cable between EV and Charge Point
Cable,
///Measurement taken by EV
#[strum(serialize = "EV")]
#[serde(rename = "EV")]
Ev,
///Measurement at network (“grid”) inlet connection
Inlet,
///Measurement at a Connector. Default value
Outlet,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum Log {
#[default]
DiagnosticsLog,
SecurityLog,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum Measurand {
///Instantaneous current flow from EV
#[strum(serialize = "Current.Export")]
#[serde(rename = "Current.Export")]
#[default]
CurrentExport,
/// Instantaneous current flow to EV
#[strum(serialize = "Current.Import")]
#[serde(rename = "Current.Import")]
CurrentImport,
/// Maximum current offered to EV
#[strum(serialize = "Current.Offered")]
#[serde(rename = "Current.Offered")]
CurrentOffered,
/// Numerical value read from the "active electrical energy" (Wh or kWh) register of the (most authoritative) electrical meter measuring energy exported (to the grid).
#[strum(serialize = "Energy.Active.Export.Register")]
#[serde(rename = "Energy.Active.Export.Register")]
EnergyActiveExportRegister,
/// Numerical value read from the "active electrical energy" (Wh or kWh) register of the (most authoritative) electrical meter measuring energy imported (from the grid supply).
#[strum(serialize = "Energy.Active.Import.Register")]
#[serde(rename = "Energy.Active.Import.Register")]
EnergyActiveImportRegister,
/// Numerical value read from the "reactive electrical energy" (`VARh` or kVARh) register of the (most authoritative) electrical meter measuring energy exported (to the grid).
#[strum(serialize = "Energy.Reactive.Export.Register")]
#[serde(rename = "Energy.Reactive.Export.Register")]
EnergyReactiveExportRegister,
/// Numerical value read from the "reactive electrical energy" (`VARh` or kVARh) register of the (most authoritative) electrical meter measuring energy imported (from the grid supply).
#[strum(serialize = "Energy.Reactive.Import.Register")]
#[serde(rename = "Energy.Reactive.Import.Register")]
EnergyReactiveImportRegister,
/// Absolute amount of "active electrical energy" (Wh or kWh) exported (to the grid) during an associated time "interval",\\
/// specified by a Metervalues `ReadingContext`, and applicable interval duration configuration values (in seconds) for "`ClockAlignedDataInterval`" and "`MeterValueSampleInterval`".
#[strum(serialize = "Energy.Active.Export.Interval")]
#[serde(rename = "Energy.Active.Export.Interval")]
EnergyActiveExportInterval,
/// Absolute amount of "active electrical energy" (Wh or kWh) imported (from the grid supply) during an associated time "interval",\\
/// specified by a Metervalues `ReadingContext`, and applicable interval duration configuration values (in seconds) for "`ClockAlignedDataInterval`" and "`MeterValueSampleInterval`".
#[strum(serialize = "Energy.Active.Import.Interval")]
#[serde(rename = "Energy.Active.Import.Interval")]
EnergyActiveImportInterval,
/// Absolute amount of "reactive electrical energy" (`VARh` or kVARh) exported (to the grid) during an associated time "interval",\\
/// specified by a Metervalues `ReadingContext`, and applicable interval duration configuration values (in seconds) for "`ClockAlignedDataInterval`" and "`MeterValueSampleInterval`".
#[strum(serialize = "Energy.Reactive.Export.Interval")]
#[serde(rename = "Energy.Reactive.Export.Interval")]
EnergyReactiveExportInterval,
/// Absolute amount of "reactive electrical energy" (`VARh` or kVARh) imported (from the grid supply) during an associated time "interval",\\
/// specified by a Metervalues `ReadingContext`, and applicable interval duration configuration values (in seconds) for "`ClockAlignedDataInterval`" and "`MeterValueSampleInterval`".
#[strum(serialize = "Energy.Reactive.Import.Interval")]
#[serde(rename = "Energy.Reactive.Import.Interval")]
EnergyReactiveImportInterval,
/// Instantaneous reading of powerline frequency. NOTE: OCPP 1.6 does not have a `UnitOfMeasure` for frequency,\\
/// the `UnitOfMeasure` for any `SampledValue` with measurand: Frequency is Hertz.
Frequency,
/// Instantaneous active power exported by EV. (W or kW)
#[strum(serialize = "Power.Active.Export")]
#[serde(rename = "Power.Active.Export")]
PowerActiveExport,
/// Instantaneous active power imported by EV. (W or kW)
#[strum(serialize = "Power.Active.Import")]
#[serde(rename = "Power.Active.Import")]
PowerActiveImport,
/// Instantaneous power factor of total energy flow
#[strum(serialize = "Power.Factor")]
#[serde(rename = "Power.Factor")]
PowerFactor,
/// Maximum power offered to EV
#[strum(serialize = "Power.Offered")]
#[serde(rename = "Power.Offered")]
PowerOffered,
/// Instantaneous reactive power exported by EV. (var or kvar)
#[strum(serialize = "Power.Reactive.Export")]
#[serde(rename = "Power.Reactive.Export")]
PowerReactiveExport,
/// Instantaneous reactive power imported by EV. (var or kvar)
#[strum(serialize = "Power.Reactive.Import")]
#[serde(rename = "Power.Reactive.Import")]
PowerReactiveImport,
/// Fan speed in RPM
#[strum(serialize = "RPM")]
#[serde(rename = "RPM")]
Rpm,
/// State of charge of charging vehicle in percentage
SoC,
/// Temperature reading inside Charge Point.
Temperature,
/// Instantaneous AC RMS supply voltage
Voltage,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum MessageTrigger {
/// To trigger a `BootNotification` request
#[default]
BootNotification,
///To trigger a `DiagnosticsStatusNotification` request
DiagnosticsStatusNotification,
/// To trigger a `FirmwareStatusNotification` request
FirmwareStatusNotification,
/// To trigger a Heartbeat request
Heartbeat,
/// To trigger a `MeterValues` request
MeterValues,
/// To trigger a `StatusNotification` request
StatusNotification,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum Phase {
#[default]
L1,
L2,
L3,
N,
#[strum(serialize = "L1-N")]
#[serde(rename = "L1-N")]
L1N,
#[strum(serialize = "L2-N")]
#[serde(rename = "L2-N")]
L2N,
#[strum(serialize = "L3-N")]
#[serde(rename = "L3-N")]
L3N,
#[strum(serialize = "L1-L2")]
#[serde(rename = "L1-L2")]
L1L2,
#[strum(serialize = "L2-L3")]
#[serde(rename = "L2-L3")]
L2L3,
#[strum(serialize = "L3-L1")]
#[serde(rename = "L3-L1")]
L3L1,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum ReadingContext {
/// Value taken at start of interruption.
#[strum(serialize = "Interruption.Begin")]
#[serde(rename = "Interruption.Begin")]
InterruptionBegin,
/// Value taken when resuming after interruption.
#[strum(serialize = "Interruption.End")]
#[serde(rename = "Interruption.End")]
InterruptionEnd,
/// Value for any other situations.
#[default]
Other,
/// Value taken at clock aligned interval.
#[strum(serialize = "Sample.Clock")]
#[serde(rename = "Sample.Clock")]
SampleClock,
/// Value taken as periodic sample relative to start time of transaction.
#[strum(serialize = "Sample.Periodic")]
#[serde(rename = "Sample.Periodic")]
SamplePeriodic,
/// Value taken at start of transaction.
#[strum(serialize = "Transaction.Begin")]
#[serde(rename = "Transaction.Begin")]
TransactionBegin,
/// Value taken at end of transaction.
#[strum(serialize = "Transaction.End")]
#[serde(rename = "Transaction.End")]
TransactionEnd,
/// Value taken in response to a TriggerMessage.req
Trigger,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default, Copy)]
pub enum Reason {
/// The transaction was stopped because of the authorization status in a StartTransaction.conf
DeAuthorized,
/// Emergency stop button was used.
EmergencyStop,
/// disconnecting of cable, vehicle moved away from inductive charge unit.
EVDisconnected,
/// A hard reset command was received.
HardReset,
/// Stopped locally on request of the user at the Charge Point. This is a regular termination of a transaction. Examples: presenting an RFID tag, pressing a button to stop.
Local,
/// Any other reason.
#[default]
Other,
/// Complete loss of power.
PowerLoss,
/// A locally initiated reset/reboot occurred. (for instance watchdog kicked in)
Reboot,
/// Stopped remotely on request of the user. This is a regular termination of a transaction. Examples: termination using a smartphone app, exceeding a (non local) prepaid credit.
Remote,
/// A soft reset command was received.
SoftReset,
/// Central System sent an Unlock Connector command.
UnlockCommand,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum RecurrencyKind {
/// The schedule restarts every 24 hours, at the same time as in the startSchedule.
#[default]
Daily,
/// The schedule restarts every 7 days, at the same time and day-of-the-week as in the startSchedule.
Weekly,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum ResetType {
/// Restart (all) the hardware, the Charge Point is not required to gracefully stop ongoing transaction.\\
/// If possible the Charge Point sends a StopTransaction.req for previously ongoing transactions after having restarted and having been accepted by the Central System via a BootNotification.conf.\\
/// This is a last resort solution for a not correctly functioning Charge Point, by sending a "hard" reset, (queued) information might get lost.
Hard,
/// Stop ongoing transactions gracefully and sending StopTransaction.req for every ongoing transaction. It should then restart the application software (if possible, otherwise restart the processor/controller).
#[default]
Soft,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum UnitOfMeasure {
/// Watt-hours (energy). Default.
Wh,
/// kiloWatt-hours (energy).
#[default]
#[serde(rename = "kWh")]
#[strum(serialize = "kWh")]
KWh,
/// Var-hours (reactive energy).
#[serde(rename = "varh")]
#[strum(serialize = "varh")]
Varh,
/// kilovar-hours (reactive energy).
#[serde(rename = "kvarh")]
#[strum(serialize = "kvarh")]
Kvarh,
/// Watts (power).
W,
/// kilowatts (power).
#[serde(rename = "kW")]
#[strum(serialize = "kW")]
Kw,
/// `VoltAmpere` (apparent power).
#[serde(rename = "VA")]
#[strum(serialize = "VA")]
Va,
/// kiloVolt Ampere (apparent power).
#[serde(rename = "kVA")]
#[strum(serialize = "kVA")]
Kva,
/// Vars (reactive power).
#[serde(rename = "var")]
#[strum(serialize = "var")]
Var,
/// kilovars (reactive power).
#[serde(rename = "kvar")]
#[strum(serialize = "kvar")]
Kvar,
/// Amperes (current).
A,
/// Voltage (r.m.s. AC).
V,
/// Degrees (temperature).
Celsius,
/// Degrees (temperature).
Fahrenheit,
/// Degrees Kelvin (temperature).
K,
/// Percentage.
Percent,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum UploadLogStatus {
BadMessage,
#[default]
Idle,
NotSupportedOperation,
PermissionDenied,
Uploaded,
UploadFailure,
Uploading,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum UpdateType {
/// Indicates that the current Local Authorization List must be updated with the values in this message.
Differential,
/// Indicates that the current Local Authorization List must be replaced by the values in this message.
#[default]
Full,
}
#[derive(AsRefStr, Debug, PartialEq, Eq, Serialize, Deserialize, Clone, Default)]
pub enum ValueFormat {
/// Data is to be interpreted as integer/decimal numeric data.
#[default]
Raw,
/// Data is represented as a signed binary data block, encoded as hex data.
SignedData,
}