German energy metering quantities: DST-correct Europe/Berlin and 06:00-Gastag calendar arithmetic, exact decimal values, and the market's own code lists. Zero I/O, no async, no clock.
Documentation
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
//! Typed OBIS (Object Identification System) codes for German energy metering.
//!
//! ## Standard
//!
//! IEC 62056-21 / DLMS-COSEM, as adopted by BDEW and Messstellenbetreiber
//! in Germany. OBIS codes identify measurement channels on smart meters and
//! data communication systems.
//!
//! ## Format
//!
//! ```text
//! A-B:C.D.E*F
//! │ │ │ │ │ └ F  Vorwertzählerstand — not used in the German market (255)
//! │ │ │ │ └── E  Tarifstufe (0 = Total, 1 = HT, 2 = NT, … 62, 63 = Fehlerregister)
//! │ │ │ └──── D  Messart (6 = Maximum, 8 = Zählerstand, 9 = Vorschub, 29 = Lastgang)
//! │ │ └────── C  Messgröße (1 = Wirkleistung +, 2 = Wirkleistung −,
//! │ │           3–8 = Blindleistung positiv/negativ/Q I–Q IV)
//! │ └──────── B  Kanal (0–65; 66 only for Blindmehrarbeit)
//! └────────── A  medium, per the DLMS/COSEM Blue Book list that OMS Vol. 2
//!               adopts: 0 = abstract, 1 = electricity, 4 = Heizkostenverteiler,
//!               5 = cooling, 6 = heat, 7 = gas, 8 = cold water, 9 = hot water
//! ```
//!
//! C, D and E are the groups that get misread most often, so they have
//! predicates rather than raw comparisons: **direction is C alone** (1 = Bezug,
//! 2 = Lieferung — EDI@Energy §2.1 writes them as `1-b:1.x.y` and `1-b:2.x.y`,
//! with `x`/`y` free), **D is a Messart, never a direction**, and **E = 63 is
//! the Fehlerregister, not tariff 63**.
//!
//! ## One code, one string
//!
//! `1-0:1.8.0` and `1-0:1.8.0*255` denote the same channel, and both occur in
//! the wild — MSCONS and hand-typed input carry the short form, meter firmware
//! often the long one. Two spellings for one channel is how a stored key ends up
//! disagreeing with itself, so this type defines exactly one canonical string:
//!
//! - **[`Display`] writes the reduced form** — `*F` omitted when F is 255.
//!   `1-0:1.8.0`.
//! - **`{:#}` writes the full six-group form** when a downstream system demands
//!   an explicit F. `1-0:1.8.0*255`.
//! - **[`FromStr`] accepts both**, plus leading zeros and surrounding
//!   whitespace, and maps them onto the same value.
//!
//! The reduced form is not a preference: the EDI@Energy *Codeliste der
//! OBIS-Kennzahlen und Medien* v2.5c (01.10.2025, binding from 01.04.2026)
//! marks both the electricity and the thermal-energy value-group diagram
//! **"A B C D E werden im deutschen Energiemarkt verwendet"**, and §2.3 states
//! again that *"Wertegruppe F wird für die Kommunikation im deutschen Gasmarkt
//! nicht verwendet"*. Every code in that list is printed without a suffix —
//! `1-b:1.8.e`, `1-b:1.29.0`, `1-b:1.6.0`. Emitting `*255` appended a value
//! group the German market does not use.
//!
//! So `s.parse::<ObisCode>()?.to_string() == s` holds for every canonical `s`,
//! and [`ObisCode::normalize`] turns any accepted spelling into that canonical
//! `s` in one call. Anything used as a database key, a merge key or a map key
//! should go through one of the two.
//!
//! [`Display`]: std::fmt::Display
//! [`FromStr`]: std::str::FromStr
//!
//! ## Commonly used codes in German MaKo
//!
//! | Code | Description |
//! |---|---|
//! | `1-0:1.8.0` | Electricity forward active energy total (kWh) |
//! | `1-0:1.8.1` | Electricity forward active energy register 1 (HT) |
//! | `1-0:1.8.2` | Electricity forward active energy register 2 (NT) |
//! | `1-0:2.8.0` | Electricity reverse active energy (Einspeisung) |
//! | `1-0:1.29.0` | Wirkarbeit Bezug — Lastgang (kWh per interval) |
//! | `1-0:1.6.0` | Wirkleistung Bezug — Maximum (kW, Spitzenleistung) |
//! | `1-0:1.9.0` | Wirkarbeit Bezug — Vorschub (kWh over a period) |
//! | `1-0:3.8.0` | Blindarbeit positiv (kvarh) |
//! | `1-0:4.8.0` | Blindarbeit negativ (kvarh) |
//! | `1-0:5.8.0` … `1-0:8.8.0` | Blindarbeit Q I … Q IV (kvarh) |
//! | `7-0:3.0.0` | Gas Betriebsvolumen, Ausspeisung (m³) — *not* a Normvolumen |
//! | `7-0:13.2.0` | Gas Normvolumen umgewertet (m³) |
//! | `7-0:52.0.22` | Zustandszahl · `7-0:54.0.22` Brennwert |
//! | `6-0:1.0.0` | Heat energy (kWh_th) — medium 6, **not** 8 |
//! | `8-0:1.0.0` | Cold water volume (m³) |
//! | `9-0:1.0.0` | Hot water volume (m³) |

use std::fmt;
use std::str::FromStr;

use crate::error::ParseError;

/// A parsed OBIS code: `A-B:C.D.E*F`.
///
/// All six value groups are stored, so two spellings of one channel are one
/// value. See the [module docs](self#one-code-one-string) for the canonical
/// string form — briefly: [`Display`](fmt::Display) writes `1-0:1.8.0`, `{:#}`
/// writes `1-0:1.8.0*255`, and [`FromStr`] reads either.
///
/// Ordering is lexicographic by value group (A, then B, … then F), which is the
/// order a channel listing is conventionally sorted in.
#[derive(Debug, Clone, Copy, PartialEq, Eq, PartialOrd, Ord, Hash)]
pub struct ObisCode {
    /// Medium: 1 = electricity, 5 = cooling, 6 = heat, 7 = gas, 8 = cold water,
    /// 9 = hot water, 4 = Heizkostenverteiler.
    pub a: u8,
    /// Kanal. For electricity: *"Die Vergabe des Kanals erfolgt durch den MSB
    /// (Wertebereich 0 bis 65) und ist für die Identifizierung relevant"*, plus
    /// 66, which the Codeliste admits only for Blindmehrarbeit und
    /// Blindmehrleistung im Lieferschein. For gas the valid range is 0–64 and
    /// the group is irrelevant except on a thermal Lastgang, where B = 10
    /// selects the Bilanzierungs- and B = 20 the Abrechnungsbrennwert.
    pub b: u8,
    /// Messgröße, and its meaning depends on [`a`](Self::a). For electricity:
    /// 1 = ∑Li Wirkleistung **+** (Bezug), 2 = ∑Li Wirkleistung **−**
    /// (Lieferung), 3 = Blindleistung positiv, 4 = negativ, 5–8 = Q I–Q IV.
    /// **Direction lives here**, not in [`d`](Self::d).
    ///
    /// For gas it instead encodes Messgröße, Quelle, Richtung and
    /// Qualifikation together — 3 = Betriebsvolumen Ausspeisung gesamt,
    /// 13 = Normvolumen umgewertet, 52 = Zustandszahl, 54 = Brennwert.
    pub c: u8,
    /// Messart — **never a direction**: 6 = Maximum, 8 = Zählerstand
    /// (Zeitintegral 1), 9 = Vorschub (Zeitintegral 2), 29 = Lastgang
    /// (Zeitintegral 5), 7 = instantaneous value.
    pub d: u8,
    /// Tarifstufe: 0 = Total, 1 = HT, 2 = NT, … up to 62 (0–9 before
    /// 2023-10-01), and [`TARIFF_FEHLERREGISTER`] (63) for the fault counter,
    /// which is not a tariff.
    ///
    /// [`TARIFF_FEHLERREGISTER`]: Self::TARIFF_FEHLERREGISTER
    pub e: u8,
    /// Vorwertzählerstand: [`STORAGE_UNUSED`] (255) = not applicable, 0–99
    /// identify stored previous readings on meters that keep them.
    ///
    /// The German market does not use this group at all — see the
    /// [module docs](self#one-code-one-string) — so it is 255 in practice and
    /// [`Display`](fmt::Display) omits it.
    ///
    /// [`STORAGE_UNUSED`]: Self::STORAGE_UNUSED
    pub f: u8,
}

impl ObisCode {
    /// Value group F when the storage / billing-period group does not apply.
    ///
    /// IEC 62056-6-1 reserves 255 for "not used", and the reduced OBIS form
    /// omits the group entirely — which is what [`Display`](fmt::Display) does.
    pub const STORAGE_UNUSED: u8 = 255;

    /// The longest string any [`ObisCode`] can render as —
    /// `255-255:255.255.255*255`, 23 bytes.
    ///
    /// Every code is ASCII, so this is a byte length and a character count
    /// alike. Use it to size a fixed-width database column: `VARCHAR(23)` holds
    /// any code in either spelling, and the canonical form is at most 19.
    pub const MAX_LEN: usize = 23;

    /// Electricity forward active energy — total (Bezug, kWh, gesamt).
    /// HT + NT combined.
    pub const STROM_BEZUG_TOTAL: Self = Self {
        a: 1,
        b: 0,
        c: 1,
        d: 8,
        e: 0,
        f: Self::STORAGE_UNUSED,
    };

    /// Electricity forward active energy — register 1 (HT, Hochtarif).
    pub const STROM_BEZUG_HT: Self = Self {
        a: 1,
        b: 0,
        c: 1,
        d: 8,
        e: 1,
        f: Self::STORAGE_UNUSED,
    };

    /// Electricity forward active energy — register 2 (NT, Niedertarif).
    pub const STROM_BEZUG_NT: Self = Self {
        a: 1,
        b: 0,
        c: 1,
        d: 8,
        e: 2,
        f: Self::STORAGE_UNUSED,
    };

    /// Electricity reverse active energy — total (Einspeisung, kWh, gesamt).
    pub const STROM_EINSPEISUNG_TOTAL: Self = Self {
        a: 1,
        b: 0,
        c: 2,
        d: 8,
        e: 0,
        f: Self::STORAGE_UNUSED,
    };

    /// Electricity reverse active energy — register 1 (HT Einspeisung).
    pub const STROM_EINSPEISUNG_HT: Self = Self {
        a: 1,
        b: 0,
        c: 2,
        d: 8,
        e: 1,
        f: Self::STORAGE_UNUSED,
    };

    /// Electricity reverse active energy — register 2 (NT Einspeisung).
    pub const STROM_EINSPEISUNG_NT: Self = Self {
        a: 1,
        b: 0,
        c: 2,
        d: 8,
        e: 2,
        f: Self::STORAGE_UNUSED,
    };

    /// Wirkarbeit Bezug — **Lastgang** (`1-0:1.29.0`), energy per equidistant
    /// interval, in **kWh**.
    ///
    /// This is the channel a [`MeterInterval`](crate::MeterInterval) usually
    /// carries: MSCONS PID 13018 / 13025 transmit it. D = 29 is *Zeitintegral 5*
    /// in the EDI@Energy Codeliste — a load profile — **not** a maximum. The
    /// peak-demand register is [`STROM_BEZUG_MAXIMUM`] (D = 6), and a demand in
    /// kW is derived from this channel by
    /// [`MeterInterval::demand_kw`](crate::MeterInterval::demand_kw).
    ///
    /// [`STROM_BEZUG_MAXIMUM`]: Self::STROM_BEZUG_MAXIMUM
    pub const STROM_BEZUG_LASTGANG: Self = Self {
        a: 1,
        b: 0,
        c: 1,
        d: 29,
        e: 0,
        f: Self::STORAGE_UNUSED,
    };

    /// Wirkarbeit Lieferung — Lastgang Einspeisung (`1-0:2.29.0`), in kWh.
    pub const STROM_EINSPEISUNG_LASTGANG: Self = Self {
        a: 1,
        b: 0,
        c: 2,
        d: 29,
        e: 0,
        f: Self::STORAGE_UNUSED,
    };

    /// Wirkleistung Bezug — **Maximum** (`1-0:1.6.0`), in kW.
    ///
    /// The Jahreshöchstleistung register priced under § 17 Abs. 2 StromNEV.
    /// D = 6 is *Maximum* in the EDI@Energy Codeliste.
    pub const STROM_BEZUG_MAXIMUM: Self = Self {
        a: 1,
        b: 0,
        c: 1,
        d: 6,
        e: 0,
        f: Self::STORAGE_UNUSED,
    };

    /// Wirkarbeit Bezug — **Vorschub** (`1-0:1.9.0`), in kWh.
    ///
    /// A Vorschub is the energy consumed over an arbitrary period — the
    /// difference between two Zählerstände. D = 9 is *Zeitintegral 2*; it is a
    /// Messart, **not** a direction. MSCONS PID 13019 carries it.
    pub const STROM_BEZUG_VORSCHUB: Self = Self {
        a: 1,
        b: 0,
        c: 1,
        d: 9,
        e: 0,
        f: Self::STORAGE_UNUSED,
    };

    /// Blindarbeit **positiv** — Zählerstand (`1-0:3.8.0`, kvarh).
    ///
    /// The EDI@Energy Codeliste names C = 3 "∑ Li Blindleistung positiv". The
    /// inductive/capacitive distinction is a property of the *quadrant*
    /// ([`STROM_BLINDARBEIT_Q1`] … [`STROM_BLINDARBEIT_Q4`]), not of the sign,
    /// so this constant is named for what the standard measures.
    ///
    /// [`STROM_BLINDARBEIT_Q1`]: Self::STROM_BLINDARBEIT_Q1
    /// [`STROM_BLINDARBEIT_Q4`]: Self::STROM_BLINDARBEIT_Q4
    pub const STROM_BLINDARBEIT_POSITIV: Self = Self {
        a: 1,
        b: 0,
        c: 3,
        d: 8,
        e: 0,
        f: Self::STORAGE_UNUSED,
    };

    /// Blindarbeit **negativ** — Zählerstand (`1-0:4.8.0`, kvarh).
    pub const STROM_BLINDARBEIT_NEGATIV: Self = Self {
        a: 1,
        b: 0,
        c: 4,
        d: 8,
        e: 0,
        f: Self::STORAGE_UNUSED,
    };

    /// Blindarbeit Quadrant I — Zählerstand (`1-0:5.8.0`, kvarh).
    pub const STROM_BLINDARBEIT_Q1: Self = Self {
        a: 1,
        b: 0,
        c: 5,
        d: 8,
        e: 0,
        f: Self::STORAGE_UNUSED,
    };

    /// Blindarbeit Quadrant II — Zählerstand (`1-0:6.8.0`, kvarh).
    pub const STROM_BLINDARBEIT_Q2: Self = Self {
        a: 1,
        b: 0,
        c: 6,
        d: 8,
        e: 0,
        f: Self::STORAGE_UNUSED,
    };

    /// Blindarbeit Quadrant III — Zählerstand (`1-0:7.8.0`, kvarh).
    pub const STROM_BLINDARBEIT_Q3: Self = Self {
        a: 1,
        b: 0,
        c: 7,
        d: 8,
        e: 0,
        f: Self::STORAGE_UNUSED,
    };

    /// Blindarbeit Quadrant IV — Zählerstand (`1-0:8.8.0`, kvarh).
    pub const STROM_BLINDARBEIT_Q4: Self = Self {
        a: 1,
        b: 0,
        c: 8,
        d: 8,
        e: 0,
        f: Self::STORAGE_UNUSED,
    };

    /// Gas **Betriebsvolumen** — Zählerstand, Ausspeisung (`7-0:3.0.0`, m³).
    ///
    /// Volume at metering conditions, *before* the Zustandszahl is applied. This
    /// is the input [`gas_m3_to_kwh_hs`](crate::gas_m3_to_kwh_hs) expects.
    ///
    /// **Not to be confused with a Normvolumen.** `7-0:13.2.0`
    /// ([`GAS_NORMVOLUMEN_UMGEWERTET`]) is already state-converted; multiplying
    /// it by a Zustandszahl applies the correction twice and overstates the
    /// energy by roughly the Zustandszahl's deviation from 1 — a few percent on
    /// a billed quantity, with no error raised.
    ///
    /// [`GAS_NORMVOLUMEN_UMGEWERTET`]: Self::GAS_NORMVOLUMEN_UMGEWERTET
    pub const GAS_VOLUME_M3: Self = Self {
        a: 7,
        b: 0,
        c: 3,
        d: 0,
        e: 0,
        f: Self::STORAGE_UNUSED,
    };

    /// Gas **Normvolumen umgewertet** — Zählerstand, Ausspeisung
    /// (`7-0:13.2.0`, m³).
    ///
    /// Already converted to standard conditions by the Mengenumwerter, so it
    /// needs the Brennwert but **not** the Zustandszahl. See
    /// [`GAS_VOLUME_M3`](Self::GAS_VOLUME_M3).
    pub const GAS_NORMVOLUMEN_UMGEWERTET: Self = Self {
        a: 7,
        b: 0,
        c: 13,
        d: 2,
        e: 0,
        f: Self::STORAGE_UNUSED,
    };

    /// Gas **Zustandszahl** — Mittelwert (`7-0:52.0.22`, dimensionless).
    pub const GAS_ZUSTANDSZAHL: Self = Self {
        a: 7,
        b: 0,
        c: 52,
        d: 0,
        e: 22,
        f: Self::STORAGE_UNUSED,
    };

    /// Gas **Brennwert** — Monatsmittelwert (`7-0:54.0.22`, kWh/m³).
    ///
    /// Value group E selects the averaging period: 16 = hourly, 20 = daily,
    /// 22 = monthly.
    pub const GAS_BRENNWERT_MONATSMITTEL: Self = Self {
        a: 7,
        b: 0,
        c: 54,
        d: 0,
        e: 22,
        f: Self::STORAGE_UNUSED,
    };

    /// Heat energy (kWh_th) — medium **6**, per the DLMS/COSEM Blue Book
    /// value-group-A list that OMS Spec Vol. 2 adopts.
    ///
    /// Medium 8 is *cold water*, not heat: see [`WASSER_KALT_VOLUME`]. Using
    /// A = 8 for a Wärmezähler puts the reading in the wrong Sparte, gives it
    /// water's daily default resolution instead of hourly, and makes
    /// [`is_heat`](Self::is_heat) report `false` for a heat register.
    ///
    /// [`WASSER_KALT_VOLUME`]: Self::WASSER_KALT_VOLUME
    pub const WAERME_ENERGY: Self = Self {
        a: 6,
        b: 0,
        c: 1,
        d: 0,
        e: 0,
        f: Self::STORAGE_UNUSED,
    };

    /// Cooling energy (kWh_th) — medium 5.
    pub const KAELTE_ENERGY: Self = Self {
        a: 5,
        b: 0,
        c: 1,
        d: 0,
        e: 0,
        f: Self::STORAGE_UNUSED,
    };

    /// Cold water volume (m³) — medium 8.
    pub const WASSER_KALT_VOLUME: Self = Self {
        a: 8,
        b: 0,
        c: 1,
        d: 0,
        e: 0,
        f: Self::STORAGE_UNUSED,
    };

    /// Hot water volume (m³) — medium 9.
    ///
    /// Billed as a volume; the heat share it apportions out of the building's
    /// heating bill is [`crate::warm_water_heat_kwh`] (HeizkostenV §9 Abs. 2).
    pub const WASSER_WARM_VOLUME: Self = Self {
        a: 9,
        b: 0,
        c: 1,
        d: 0,
        e: 0,
        f: Self::STORAGE_UNUSED,
    };

    /// `true` when this code refers to electricity (medium A = 1).
    #[must_use]
    pub fn is_electricity(&self) -> bool {
        self.a == 1
    }

    /// `true` when this code refers to gas (medium A = 7).
    #[must_use]
    pub fn is_gas(&self) -> bool {
        self.a == 7
    }

    /// `true` when this code refers to thermal energy — cooling (A = 5) or
    /// heat (A = 6).
    ///
    /// Media are numbered per the DLMS/COSEM Blue Book value-group-A list, which
    /// OMS Spec Vol. 2 adopts.
    #[must_use]
    pub fn is_heat(&self) -> bool {
        matches!(self.a, 5 | 6)
    }

    /// `true` when this code refers to water — cold (A = 8) or hot (A = 9).
    #[must_use]
    pub fn is_water(&self) -> bool {
        matches!(self.a, 8 | 9)
    }

    /// `true` when this code refers to a Heizkostenverteiler (A = 4).
    ///
    /// HCAs report dimensionless *Verbrauchseinheiten*, not a physical quantity.
    ///
    /// They carry **no Eichfrist**, because they are not Messgeräte under
    /// MessEG at all — "Heizkostenverteiler" appears nowhere in MessEV, neither
    /// in Anlage 1 nor in the Eichfristen of Anlage 7. HeizkostenV §5 Abs. 1
    /// admits them through an explicitly conditional clause — *"soweit nicht
    /// eichrechtliche Bestimmungen zur Anwendung kommen"* — requiring instead
    /// that an expert body confirm conformity with the anerkannte Regeln der
    /// Technik (EN 834 for evaporation, EN 835 for electronic HCAs).
    ///
    /// So an Eichfrist check must **skip** these devices rather than treat a
    /// missing date as an expiry.
    #[must_use]
    pub fn is_heat_cost_allocator(&self) -> bool {
        self.a == 4
    }

    /// `true` when this code measures reactive energy or power (Blindarbeit /
    /// Blindleistung) — electricity C = 3…8.
    ///
    /// The EDI@Energy Codeliste assigns C = 3 to Blindleistung positiv, C = 4 to
    /// negativ, and **C = 5…8 to the four quadrants Q I…Q IV**. Checking only
    /// 3 and 4 reports a quadrant register as active energy, which puts a kvarh
    /// value into a kWh column.
    ///
    /// Reactive energy is required for Blindstromberechnung in industrial
    /// tariffs, for SMGW power quality monitoring (BSI TR-03109) and for RLM
    /// power quality records.
    #[must_use]
    pub fn is_reactive(&self) -> bool {
        self.a == 1 && matches!(self.c, 3..=8)
    }

    /// `true` when this code is a **Lastgang** — energy per equidistant interval
    /// (D = 29, *Zeitintegral 5*).
    ///
    /// This is what a [`MeterInterval`](crate::MeterInterval) carries. It is an
    /// energy quantity in kWh, **not** a power in kW: see
    /// [`is_maximum`](Self::is_maximum) for the peak-demand register.
    #[must_use]
    pub fn is_lastgang(&self) -> bool {
        self.d == 29
    }

    /// `true` when this code is a **maximum** register (D = 6).
    ///
    /// `1-0:1.6.0` is the Jahreshöchstleistung priced under § 17 Abs. 2 StromNEV.
    /// D = 29 is the load profile it is derived from, not the maximum itself —
    /// conflating the two bills a 15-minute energy quantity as a power.
    #[must_use]
    pub fn is_maximum(&self) -> bool {
        self.d == 6
    }

    /// `true` when this code is a **Zählerstand** — a cumulative meter reading
    /// (D = 8, *Zeitintegral 1*).
    #[must_use]
    pub fn is_zaehlerstand(&self) -> bool {
        self.d == 8
    }

    /// `true` when this code is a **Vorschub** — the energy consumed over an
    /// arbitrary period, i.e. the difference of two Zählerstände (D = 9,
    /// *Zeitintegral 2*).
    #[must_use]
    pub fn is_vorschub(&self) -> bool {
        self.d == 9
    }

    /// The direction this code counts in, if it counts in one.
    ///
    /// Direction lives in value group **C alone**: EDI@Energy §2.1 states
    /// "+ Bezug des Kunden aus dem Netz (z. B. `1-b:1.x.y`)" and "− (Rück-)
    /// Lieferung des Kunden an das Netz (z. B. `1-b:2.x.y`)", with `x` and `y`
    /// explicitly free. So the Zählerstand `1-0:1.8.0`, the Vorschub
    /// `1-0:1.9.0`, the Lastgang `1-0:1.29.0` and the Maximum `1-0:1.6.0` are
    /// all import; the Messart D is not part of the direction, and `D = 9` is
    /// *Vorschub*, not a reverse flag.
    ///
    /// Requiring D = 8 would report the Lastgang — the commonest code in
    /// MSCONS interval data — as having no direction at all.
    ///
    /// `None` for every code that genuinely has none: reactive power
    /// (C = 3, 4), apparent power, gas volume, a Zustandszahl. This is the
    /// **primitive**; [`is_import`](Self::is_import) and
    /// [`is_export`](Self::is_export) are derived from it, because two
    /// booleans that are both `false` cannot distinguish "this register has no
    /// direction" from "this register counts the other way".
    ///
    /// ```rust
    /// use metering::{Direction, ObisCode};
    ///
    /// let bezug: ObisCode = "1-0:1.8.0".parse()?;
    /// let einspeisung: ObisCode = "1-0:2.8.0".parse()?;
    /// let blind: ObisCode = "1-0:3.8.0".parse()?;
    ///
    /// assert_eq!(bezug.direction(), Some(Direction::Import));
    /// assert_eq!(einspeisung.direction(), Some(Direction::Export));
    /// assert_eq!(blind.direction(), None, "Blindarbeit has no flow direction");
    /// # Ok::<(), metering::ParseError>(())
    /// ```
    #[must_use]
    pub const fn direction(self) -> Option<crate::interval::Direction> {
        use crate::interval::Direction;
        match (self.a, self.c) {
            (1, 1) => Some(Direction::Import),
            (1, 2) => Some(Direction::Export),
            _ => None,
        }
    }

    /// `true` when this code counts Bezug — see [`direction`](Self::direction).
    #[must_use]
    pub const fn is_import(self) -> bool {
        matches!(self.direction(), Some(crate::interval::Direction::Import))
    }

    /// `true` when this code counts Einspeisung — see
    /// [`direction`](Self::direction).
    #[must_use]
    pub const fn is_export(self) -> bool {
        matches!(self.direction(), Some(crate::interval::Direction::Export))
    }

    /// Value group E when the register counts faults rather than energy.
    ///
    /// EDI@Energy Codeliste §2.2 lists "63 Fehlerregister" alongside the
    /// tariffs, so 63 is not a tariff number and its contents are not a billable
    /// quantity.
    pub const TARIFF_FEHLERREGISTER: u8 = 63;

    /// Tariff register: `None` = total/combined (E = 0), `Some(1)` = HT,
    /// `Some(2)` = NT, up to `Some(62)`.
    ///
    /// Returns `None` for the **Fehlerregister** (E = 63) as well, because it is
    /// not a tariff — reporting it as `Some(63)` invites a caller to bill a
    /// fault counter as tariff 63's consumption. Distinguish the two cases with
    /// [`is_total_register`](Self::is_total_register) or
    /// [`is_fehlerregister`](Self::is_fehlerregister).
    ///
    /// Tariffs ran 0…9 until 2023-10-01 and 0…62 since.
    #[must_use]
    pub fn tariff_register(&self) -> Option<u8> {
        match self.e {
            0 | Self::TARIFF_FEHLERREGISTER => None,
            n => Some(n),
        }
    }

    /// `true` when this is the Fehlerregister (E = 63) rather than a tariff.
    ///
    /// A Fehlerregister counts fault occurrences. Its value must never be
    /// summed into an Arbeitsmenge.
    #[must_use]
    pub const fn is_fehlerregister(&self) -> bool {
        self.e == Self::TARIFF_FEHLERREGISTER
    }

    /// `true` when this is the total / combined register (E = 0).
    #[must_use]
    pub fn is_total_register(&self) -> bool {
        self.e == 0
    }

    /// `true` when this is the HT (Hochtarif) register (E = 1).
    #[must_use]
    pub fn is_ht(&self) -> bool {
        self.e == 1
    }

    /// `true` when this is the NT (Niedertarif) register (E = 2).
    #[must_use]
    pub fn is_nt(&self) -> bool {
        self.e == 2
    }

    /// The grid a series on this channel is ordinarily delivered on.
    ///
    /// A *default*, not a guarantee: it is the expectation an ingest path
    /// starts from when the message carries no explicit resolution. What the
    /// series actually holds is
    /// [`detect_interval_length`](crate::detect_interval_length).
    ///
    /// `None` where the channel is **not an equidistant series at all**, which
    /// is a different answer from "some resolution we cannot name" and the
    /// reason this returns an `Option`:
    ///
    /// | Channel | Answer | Why |
    /// |---|---|---|
    /// | Fehlerregister, E = 63 | `None` | counts faults, not energy over time |
    /// | Maximum, electricity D = 6 | `None` | one figure per billing period |
    /// | Vorschub, electricity D = 9 | `None` | an arbitrary period, by definition off-grid |
    /// | Momentanwert, electricity D = 7 | `None` | an instant, not an interval |
    /// | electricity Zählerstand / Lastgang, C = 1…8 | `PT15M` | § 2 Satz 1 Nr. 27 MsbG |
    /// | gas Zustandszahl / Brennwert, C = 52 / 54 | from value group E | 16 hourly, 20 daily, 22 monthly |
    /// | other gas | `PT1H` | § 2 Satz 1 Nr. 27 MsbG: *stündlich* for gas |
    /// | heat, cooling (A = 5, 6) | `PT1H` | |
    /// | cold, hot water (A = 8, 9) | `P1D` | submetering is read daily at best |
    ///
    /// The Messart exclusions apply on the **electricity** axis only. Value
    /// group C carries a different vocabulary for gas — Messgröße, Quelle,
    /// Richtung and Qualifikation at once — and D is not a Messart there.
    ///
    /// ```rust
    /// use metering::{IntervalResolution, ObisCode};
    ///
    /// assert_eq!(
    ///     ObisCode::STROM_BEZUG_LASTGANG.default_resolution(),
    ///     Some(IntervalResolution::QuarterHour),
    /// );
    /// // A Brennwert published as a monthly mean is not an hourly series.
    /// assert_eq!(
    ///     ObisCode::GAS_BRENNWERT_MONATSMITTEL.default_resolution(),
    ///     Some(IntervalResolution::Month),
    /// );
    /// // A maximum register is one number per period, whether active…
    /// assert_eq!(ObisCode::STROM_BEZUG_MAXIMUM.default_resolution(), None);
    /// // …or reactive.
    /// assert_eq!("1-0:5.6.0".parse::<ObisCode>()?.default_resolution(), None);
    /// # Ok::<(), metering::ParseError>(())
    /// ```
    #[must_use]
    pub const fn default_resolution(&self) -> Option<crate::resolution::IntervalResolution> {
        use crate::resolution::IntervalResolution as R;
        // A fault counter is not a time series at any resolution.
        if self.is_fehlerregister() {
            return None;
        }
        match self.a {
            // Electricity: the Messart says whether this is a series at all,
            // and the Messgröße whether it is a quantity this crate names.
            1 => match (self.c, self.d) {
                // Zählerstand (Zeitintegral 1) and Lastgang (Zeitintegral 5),
                // active and reactive alike — the quarter-hour grid of
                // § 2 Satz 1 Nr. 27 MsbG.
                (1..=8, 8 | 29) => Some(R::QuarterHour),
                // Maximum (6), Vorschub (9), Momentanwert (7) and anything
                // else: not an equidistant series.
                _ => None,
            },
            // Cooling and heat meters deliver hourly.
            5 | 6 => Some(R::Hour),
            // Gas: value group E names the averaging period of the two
            // conversion parameters the Codeliste publishes as Mittelwerte.
            // Treating `7-0:54.0.22` as an hourly channel called a monthly
            // Brennwert an hourly one.
            7 => match (self.c, self.e) {
                (52 | 54, 16) => Some(R::Hour),
                (52 | 54, 20) => Some(R::Day),
                (52 | 54, 22) => Some(R::Month),
                (52 | 54, _) => None,
                // Volumes and energies: *stündlich ermittelte Zählerstände von
                // Gasmengen*. An SLP delivery point is allocated daily, but
                // that is a settlement grid the caller chooses, not a property
                // of the channel.
                _ => Some(R::Hour),
            },
            // Water — cold (8) and hot (9). Submetering is read daily at best.
            8 | 9 => Some(R::Day),
            // Abstract (0), Heizkostenverteiler (4) and everything unmodelled.
            _ => None,
        }
    }

    /// The physical unit this register counts in, derived from the value
    /// groups.
    ///
    /// A stored `unit` field would be a second source of truth that can
    /// contradict the code — a register tagged `KWh` with code `1-0:3.8.0` is
    /// kvarh however the field is set — so the unit is derived rather than
    /// carried.
    ///
    /// `None` for a code whose unit this crate cannot name: an abstract code
    /// (medium 0), a Heizkostenverteiler (medium 4, which counts dimensionless
    /// Verbrauchseinheiten), or an electricity Messgröße outside the active and
    /// reactive groups.
    ///
    /// ```rust
    /// use metering::obis::{ObisCode, RegisterUnit};
    ///
    /// assert_eq!(ObisCode::STROM_BEZUG_TOTAL.register_unit(),      Some(RegisterUnit::KiloWattHour));
    /// assert_eq!(ObisCode::STROM_BLINDARBEIT_Q1.register_unit(),   Some(RegisterUnit::KiloVarHour));
    /// assert_eq!(ObisCode::STROM_BEZUG_MAXIMUM.register_unit(),    Some(RegisterUnit::KiloWatt));
    /// assert_eq!(ObisCode::GAS_VOLUME_M3.register_unit(),          Some(RegisterUnit::CubicMetre));
    /// assert_eq!(ObisCode::WAERME_ENERGY.register_unit(),          Some(RegisterUnit::KiloWattHourThermal));
    /// // A Heizkostenverteiler counts units, not a physical quantity.
    /// assert_eq!("4-0:1.0.0".parse::<ObisCode>().unwrap().register_unit(), None);
    /// ```
    #[must_use]
    pub fn register_unit(&self) -> Option<RegisterUnit> {
        match self.a {
            // Electricity: the Messgröße picks active or reactive, the Messart
            // picks energy or power.
            1 => {
                let reactive = self.is_reactive();
                let active = matches!(self.c, 1 | 2);
                if !reactive && !active {
                    return None;
                }
                Some(match (reactive, self.is_maximum()) {
                    (false, false) => RegisterUnit::KiloWattHour,
                    (false, true) => RegisterUnit::KiloWatt,
                    (true, false) => RegisterUnit::KiloVarHour,
                    (true, true) => RegisterUnit::KiloVar,
                })
            }
            // Cooling and heat meters register thermal energy.
            5 | 6 => Some(RegisterUnit::KiloWattHourThermal),
            // Gas and water registers count a volume.
            7..=9 => Some(RegisterUnit::CubicMetre),
            _ => None,
        }
    }

    /// The **Lastgang** channel of this register — the same measurement as a
    /// series of energies per equidistant interval (D = 29).
    ///
    /// This is the relabelling a Zählerstandsgang → Lastgang conversion owes
    /// its output. `1-0:1.8.0` differenced into intervals is `1-0:1.29.0`, and
    /// carrying the Zählerstand code through instead makes every downstream
    /// register projection treat interval energies as cumulative readings.
    ///
    /// `None` off the electricity axis, and for a register the market defines
    /// no Lastgang for:
    ///
    /// - **Not medium 1.** For gas, value group C encodes Messgröße, Quelle,
    ///   Richtung *and* Qualifikation together and a profile is C = 99, so
    ///   D = 29 means nothing there — a distinction a medium-blind caller gets
    ///   wrong.
    /// - **Not an active or reactive Messgröße** (C = 1…8).
    /// - **Not the total register.** The Codeliste v2.5c §3.1 lists the
    ///   Zählerstand as `1-b:1.8.e` — tariff-differentiated — and the Lastgang
    ///   only as `1-b:1.29.0`. There is no tariff-differentiated Lastgang, so
    ///   an HT register has no Lastgang code and this refuses to invent one
    ///   rather than silently collapsing HT and NT onto the same channel.
    ///   Split a total Lastgang across registers with
    ///   [`Zaehlzeitdefinition`](crate::Zaehlzeitdefinition) instead.
    ///
    /// ```rust
    /// use metering::ObisCode;
    ///
    /// let bezug: ObisCode = "1-0:1.8.0".parse()?;
    /// assert_eq!(bezug.as_lastgang(), Some(ObisCode::STROM_BEZUG_LASTGANG));
    ///
    /// // Direction is preserved — the failure a hard-coded constant makes.
    /// let einspeisung: ObisCode = "1-0:2.8.0".parse()?;
    /// assert_eq!(
    ///     einspeisung.as_lastgang(),
    ///     Some(ObisCode::STROM_EINSPEISUNG_LASTGANG),
    /// );
    ///
    /// // ...and it round-trips.
    /// assert_eq!(bezug.as_lastgang().unwrap().as_zaehlerstand(), Some(bezug));
    ///
    /// // No Lastgang exists for a tariff register or off the electricity axis.
    /// assert_eq!("1-0:1.8.1".parse::<ObisCode>()?.as_lastgang(), None);
    /// assert_eq!(ObisCode::GAS_VOLUME_M3.as_lastgang(), None);
    /// # Ok::<(), metering::ParseError>(())
    /// ```
    #[must_use]
    pub const fn as_lastgang(&self) -> Option<Self> {
        if !self.is_convertible_messart() || self.e != 0 {
            return None;
        }
        Some(Self { d: 29, ..*self })
    }

    /// The **Zählerstand** channel of this register — the cumulative reading
    /// the Lastgang was differenced out of (D = 8, *Zeitintegral 1*).
    ///
    /// The inverse of [`as_lastgang`](Self::as_lastgang), and defined for a
    /// tariff register too: the Codeliste lists `1-b:1.8.e` across the tariff
    /// range and `1-b:1.8.63` for the Fehlerregister.
    ///
    /// `None` under the same medium and Messgröße conditions as
    /// [`as_lastgang`](Self::as_lastgang).
    #[must_use]
    pub const fn as_zaehlerstand(&self) -> Option<Self> {
        if !self.is_convertible_messart() {
            return None;
        }
        Some(Self { d: 8, ..*self })
    }

    /// The **Vorschub** channel of this register — the energy over an arbitrary
    /// period, i.e. the difference of two Zählerstände (D = 9, *Zeitintegral
    /// 2*).
    ///
    /// This is the honest label for what
    /// [`consumption_between`](crate::reading::consumption_between) computes: a
    /// Jahresablesung differenced against the previous one is a Vorschub, not a
    /// Lastgang, because the period is not part of an equidistant grid.
    ///
    /// `None` under the same conditions as [`as_lastgang`](Self::as_lastgang),
    /// except that a Vorschub, like a Zählerstand, exists per tariff.
    #[must_use]
    pub const fn as_vorschub(&self) -> Option<Self> {
        if !self.is_convertible_messart() {
            return None;
        }
        Some(Self { d: 9, ..*self })
    }

    /// Whether the Messart conversions above are defined for this code:
    /// electricity, and an active or reactive Messgröße.
    const fn is_convertible_messart(&self) -> bool {
        self.a == 1 && matches!(self.c, 1..=8)
    }

    /// `true` when value group F is [`STORAGE_UNUSED`] — the ordinary case, and
    /// the one where [`Display`](fmt::Display) omits the `*F` suffix.
    ///
    /// [`STORAGE_UNUSED`]: Self::STORAGE_UNUSED
    #[must_use]
    pub const fn has_unused_storage(&self) -> bool {
        self.f == Self::STORAGE_UNUSED
    }

    /// Parse from a string slice (lenient: `*F`, leading zeros and surrounding
    /// whitespace are all optional).
    ///
    /// # Errors
    ///
    /// Returns a [`ParseError`] when the string does not conform to OBIS format.
    pub fn parse(s: &str) -> Result<Self, ParseError> {
        s.parse()
    }

    /// The full six-group form, with `*F` always explicit — `1-0:1.8.0*255`.
    ///
    /// Equivalent to `format!("{code:#}")`. Use it when a downstream system
    /// insists on the long spelling; [`to_string`](ToString::to_string) is the
    /// canonical form and the one to key on.
    ///
    /// ```rust
    /// # use metering::ObisCode;
    /// let code = ObisCode::STROM_BEZUG_TOTAL;
    /// assert_eq!(code.to_string(),      "1-0:1.8.0");
    /// assert_eq!(code.to_full_string(), "1-0:1.8.0*255");
    /// ```
    #[must_use]
    pub fn to_full_string(&self) -> String {
        format!("{self:#}")
    }

    /// Rewrite any accepted spelling of an OBIS code as the canonical one.
    ///
    /// For consumers holding raw strings — a database column, a CSV cell, an
    /// MSCONS segment — that need one spelling per channel without building a
    /// value first. Idempotent: normalising a normalised code returns it
    /// unchanged.
    ///
    /// ```rust
    /// # use metering::ObisCode;
    /// assert_eq!(ObisCode::normalize("1-0:1.8.0*255")?, "1-0:1.8.0");
    /// assert_eq!(ObisCode::normalize("  1-0:01.8.0 ")?, "1-0:1.8.0");
    /// assert_eq!(ObisCode::normalize("1-0:1.8.0")?,     "1-0:1.8.0");
    /// // A real billing-period register keeps its F group.
    /// assert_eq!(ObisCode::normalize("1-0:1.8.0*1")?,   "1-0:1.8.0*1");
    /// # Ok::<(), metering::ParseError>(())
    /// ```
    ///
    /// # Errors
    ///
    /// Returns a [`ParseError`] when the string does not conform to OBIS format.
    pub fn normalize(s: &str) -> Result<String, ParseError> {
        Ok(s.parse::<Self>()?.to_string())
    }
}

/// The physical unit a meter register counts in.
///
/// Finer than [`MeasurementUnit`](crate::MeasurementUnit), which is the
/// *storage* vocabulary and has exactly two values. This distinguishes energy
/// from power and active from reactive, because a register does.
#[derive(Debug, Clone, Copy, PartialEq, Eq, Hash)]
#[cfg_attr(feature = "serde", derive(serde::Serialize, serde::Deserialize))]
#[cfg_attr(feature = "serde", serde(rename_all = "SCREAMING_SNAKE_CASE"))]
pub enum RegisterUnit {
    /// Active energy, kWh.
    KiloWattHour,
    /// Reactive energy, kvarh.
    KiloVarHour,
    /// Active power, kW — a maximum register.
    KiloWatt,
    /// Reactive power, kvar — a maximum register.
    KiloVar,
    /// Volume, m³ — gas and water.
    CubicMetre,
    /// Thermal energy, kWh_th — heat and cooling.
    KiloWattHourThermal,
}

impl RegisterUnit {
    /// Every variant, in declaration order.
    pub const ALL: [Self; 6] = [
        Self::KiloWattHour,
        Self::KiloVarHour,
        Self::KiloWatt,
        Self::KiloVar,
        Self::CubicMetre,
        Self::KiloWattHourThermal,
    ];

    /// Stable DB/wire label. Matches the `serde` tag and `FromStr` input.
    ///
    /// [`symbol`](Self::symbol) is the display form (`kWh`, `m³`); this is the
    /// code. They differ deliberately — a symbol carrying a superscript is not
    /// something to put in a database `CHECK` constraint.
    #[must_use]
    pub const fn as_str(self) -> &'static str {
        match self {
            Self::KiloWattHour => "KILO_WATT_HOUR",
            Self::KiloVarHour => "KILO_VAR_HOUR",
            Self::KiloWatt => "KILO_WATT",
            Self::KiloVar => "KILO_VAR",
            Self::CubicMetre => "CUBIC_METRE",
            Self::KiloWattHourThermal => "KILO_WATT_HOUR_THERMAL",
        }
    }

    /// The unit symbol, as printed on a meter display.
    #[must_use]
    pub const fn symbol(self) -> &'static str {
        match self {
            Self::KiloWattHour => "kWh",
            Self::KiloVarHour => "kvarh",
            Self::KiloWatt => "kW",
            Self::KiloVar => "kvar",
            Self::CubicMetre => "m³",
            Self::KiloWattHourThermal => "kWh_th",
        }
    }

    /// `true` when the register counts a quantity that accumulates — an energy
    /// or a volume — rather than an instantaneous power.
    ///
    /// Only a cumulative register can be differenced into a Lastgang; see
    /// [`crate::reading`].
    #[must_use]
    pub const fn is_cumulative(self) -> bool {
        !matches!(self, Self::KiloWatt | Self::KiloVar)
    }
}

crate::codes::string_codes! {
    RegisterUnit;
}

/// A stack buffer sized for the longest code [`ObisCode`] can write, so
/// [`Display`](fmt::Display) can hand a complete `&str` to
/// [`Formatter::pad`](fmt::Formatter::pad) without allocating.
struct CodeBuf {
    buf: [u8; ObisCode::MAX_LEN],
    len: usize,
}

impl CodeBuf {
    const fn new() -> Self {
        Self {
            buf: [0; ObisCode::MAX_LEN],
            len: 0,
        }
    }

    /// Always valid UTF-8: only ASCII digits and separators are ever written.
    fn as_str(&self) -> Result<&str, fmt::Error> {
        std::str::from_utf8(&self.buf[..self.len]).map_err(|_| fmt::Error)
    }
}

impl fmt::Write for CodeBuf {
    fn write_str(&mut self, s: &str) -> fmt::Result {
        let end = self.len.checked_add(s.len()).ok_or(fmt::Error)?;
        let dst = self.buf.get_mut(self.len..end).ok_or(fmt::Error)?;
        dst.copy_from_slice(s.as_bytes());
        self.len = end;
        Ok(())
    }
}

impl fmt::Display for ObisCode {
    /// Writes the canonical reduced form, omitting `*F` when F is
    /// [`STORAGE_UNUSED`](Self::STORAGE_UNUSED).
    ///
    /// The alternate flag `{:#}` forces the full six-group form — see
    /// [`to_full_string`](Self::to_full_string). Width, fill and alignment are
    /// honoured, so `{:>13}` lines a code up in a table.
    fn fmt(&self, f: &mut fmt::Formatter<'_>) -> fmt::Result {
        use fmt::Write as _;

        let mut buf = CodeBuf::new();
        write!(
            buf,
            "{}-{}:{}.{}.{}",
            self.a, self.b, self.c, self.d, self.e
        )?;
        if f.alternate() || !self.has_unused_storage() {
            write!(buf, "*{}", self.f)?;
        }
        f.pad(buf.as_str()?)
    }
}

impl From<ObisCode> for String {
    fn from(o: ObisCode) -> String {
        o.to_string()
    }
}

/// The shape [`ObisCode`] accepts, as rendered in a [`ParseError`].
const OBIS_FORMAT: &str = "A-B:C.D.E*F, e.g. 1-0:1.8.0 (the *F suffix is optional)";

impl FromStr for ObisCode {
    type Err = ParseError;

    fn from_str(s: &str) -> Result<Self, Self::Err> {
        parse_obis(s).ok_or_else(|| ParseError::format("ObisCode", s, OBIS_FORMAT))
    }
}

impl TryFrom<&str> for ObisCode {
    type Error = ParseError;
    fn try_from(s: &str) -> Result<Self, Self::Error> {
        s.parse()
    }
}

// ── Lenient parser ────────────────────────────────────────────────────────────

/// Both spellings of `A-B:C.D.E*F`, plus leading zeros and surrounding
/// whitespace. Everything it accepts maps onto a single canonical
/// [`Display`](fmt::Display) output.
fn parse_obis(s: &str) -> Option<ObisCode> {
    let (a_str, rest) = s.trim().split_once('-')?;
    let (b_str, cd_ef) = rest.split_once(':')?;

    // C.D.E*F or C.D.E — the storage group is optional.
    let (cde, f_str) = match cd_ef.split_once('*') {
        Some((l, r)) => (l, Some(r)),
        None => (cd_ef, None),
    };
    let (c_str, d_e) = cde.split_once('.')?;
    let (d_str, e_str) = d_e.split_once('.')?;

    Some(ObisCode {
        a: group(a_str)?,
        b: group(b_str)?,
        c: group(c_str)?,
        d: group(d_str)?,
        e: group(e_str)?,
        f: match f_str {
            Some(t) => group(t)?,
            None => ObisCode::STORAGE_UNUSED,
        },
    })
}

/// One value group: ASCII digits only.
///
/// `u8::from_str` alone would accept a `+` sign, so `+1-0:1.8.0*+255` parsed and
/// then rendered as `1-0:1.8.0` — a second spelling sneaking past the front
/// door. A group is digits or it is not a group.
fn group(s: &str) -> Option<u8> {
    if s.is_empty() || !s.bytes().all(|b| b.is_ascii_digit()) {
        return None;
    }
    s.parse().ok()
}

// ── Serde: one string on the wire, readable from any deserialiser ─────────────

#[cfg(feature = "serde")]
mod serde_impl {
    use super::ObisCode;
    use serde::de::{self, Visitor};
    use serde::{Deserialize, Deserializer, Serialize, Serializer};
    use std::fmt;

    impl Serialize for ObisCode {
        /// Writes the canonical [`Display`](fmt::Display) form, without an
        /// intermediate `String`.
        fn serialize<S: Serializer>(&self, serializer: S) -> Result<S::Ok, S::Error> {
            serializer.collect_str(self)
        }
    }

    struct ObisCodeVisitor;

    impl Visitor<'_> for ObisCodeVisitor {
        type Value = ObisCode;

        fn expecting(&self, f: &mut fmt::Formatter<'_>) -> fmt::Result {
            f.write_str("an OBIS code string such as \"1-0:1.8.0\"")
        }

        fn visit_str<E: de::Error>(self, v: &str) -> Result<ObisCode, E> {
            v.parse().map_err(de::Error::custom)
        }
    }

    impl<'de> Deserialize<'de> for ObisCode {
        /// Accepts either spelling, from borrowing and non-borrowing
        /// deserialisers alike — `serde_json::from_reader`, bincode, postcard
        /// and MessagePack included. A visitor is what makes that work; a
        /// `try_from = "&str"` bridge would demand a borrowed `&str` and fail
        /// on all four.
        fn deserialize<D: Deserializer<'de>>(deserializer: D) -> Result<Self, D::Error> {
            deserializer.deserialize_str(ObisCodeVisitor)
        }
    }
}

#[cfg(test)]
mod tests {
    use super::*;

    #[test]
    fn parse_standard_strom_bezug() {
        let code: ObisCode = "1-0:1.8.0*255".parse().unwrap();
        assert_eq!(code, ObisCode::STROM_BEZUG_TOTAL);
        assert!(code.is_electricity());
        assert!(code.is_import(), "1-0:1.8.0 C=1,D=8 should be import");
        assert!(code.is_total_register());
        assert!(!code.is_export());
    }

    #[test]
    fn parse_ht_register() {
        let code: ObisCode = "1-0:1.8.1*255".parse().unwrap();
        assert_eq!(code, ObisCode::STROM_BEZUG_HT);
        assert!(code.is_ht());
        assert!(!code.is_nt());
        assert_eq!(code.tariff_register(), Some(1));
    }

    #[test]
    fn parse_without_storage_number() {
        // *255 is optional — an absent F group means "not applicable".
        let code: ObisCode = "1-0:2.8.0".parse().unwrap();
        assert_eq!(code.f, 255);
        assert_eq!(code.c, 2);
        assert_eq!(code.d, 8);
        // C=2, D=8 = reverse active energy (Einspeisung)
        assert!(
            code.is_export(),
            "1-0:2.8.0 should be Einspeisung/export (C=2, D=8)"
        );
        assert_eq!(code, ObisCode::STROM_EINSPEISUNG_TOTAL);
    }

    #[test]
    fn parse_gas_volume() {
        let code: ObisCode = "7-0:3.0.0*255".parse().unwrap();
        assert_eq!(code, ObisCode::GAS_VOLUME_M3);
        assert!(code.is_gas());
        assert!(!code.is_electricity());
    }

    #[test]
    fn invalid_code_returns_error() {
        assert!("not-an-obis".parse::<ObisCode>().is_err());
        assert!("1-0:1.8".parse::<ObisCode>().is_err());
        assert!("".parse::<ObisCode>().is_err());
    }

    #[test]
    fn constants_are_correct() {
        assert_eq!(ObisCode::STROM_BEZUG_TOTAL.to_string(), "1-0:1.8.0");
        assert_eq!(ObisCode::STROM_BEZUG_HT.to_string(), "1-0:1.8.1");
        assert_eq!(ObisCode::STROM_BEZUG_NT.to_string(), "1-0:1.8.2");
        assert_eq!(ObisCode::STROM_EINSPEISUNG_TOTAL.to_string(), "1-0:2.8.0");
        assert_eq!(ObisCode::GAS_VOLUME_M3.to_string(), "7-0:3.0.0");
    }
}

/// Value-group semantics, against the EDI@Energy *Codeliste der OBIS-Kennzahlen
/// und Medien* v2.5c (§2.1, §2.2, §2.3, §3.1).
///
/// The predicates read the German market's assignment of the value groups, not
/// the bare IEC group names, and each case below pins one of them.
#[cfg(test)]
mod mako_semantics_tests {
    use super::*;

    /// Direction is value group C alone. Requiring D = 8 reported the Lastgang —
    /// the code MSCONS PID 13018 carries, and the one a `MeterInterval` holds —
    /// as neither import nor export.
    #[test]
    fn direction_is_group_c_across_every_messart() {
        for (code, what) in [
            ("1-0:1.8.0", "Zählerstand"),
            ("1-0:1.9.0", "Vorschub"),
            ("1-0:1.29.0", "Lastgang"),
            ("1-0:1.6.0", "Maximum"),
            ("1-0:1.8.1", "Zählerstand HT"),
        ] {
            let c: ObisCode = code.parse().unwrap();
            assert!(c.is_import(), "{code} ({what}) is Bezug");
            assert!(!c.is_export(), "{code} ({what}) is not Lieferung");
        }

        for (code, what) in [
            ("1-0:2.8.0", "Zählerstand"),
            ("1-0:2.9.0", "Vorschub"),
            ("1-0:2.29.0", "Lastgang"),
            ("1-0:2.6.0", "Maximum"),
        ] {
            let c: ObisCode = code.parse().unwrap();
            assert!(c.is_export(), "{code} ({what}) is Lieferung");
            assert_eq!(c.direction(), Some(crate::interval::Direction::Export));
            assert!(!c.is_import(), "{code} ({what}) is not Bezug");
        }
    }

    /// D is a Messart, not a direction. `1-0:3.9.0` is "Blindarbeit positiv,
    /// Vorschub" — it was modelled as an *export* register.
    #[test]
    fn messart_is_not_a_direction() {
        let vorschub: ObisCode = "1-0:1.9.0".parse().unwrap();
        assert!(vorschub.is_vorschub() && vorschub.is_import());

        let blind_vorschub: ObisCode = "1-0:3.9.0".parse().unwrap();
        assert!(blind_vorschub.is_vorschub());
        assert!(blind_vorschub.is_reactive());
        assert!(
            !blind_vorschub.is_export(),
            "D = 9 is Vorschub (Zeitintegral 2), not a reverse-direction flag"
        );
    }

    /// A Lastgang is energy per interval (kWh); a Maximum is a power (kW).
    /// Billing the first as the second overstates the Leistungspreis basis.
    #[test]
    fn lastgang_and_maximum_are_different_registers() {
        let lastgang = ObisCode::STROM_BEZUG_LASTGANG;
        let maximum = ObisCode::STROM_BEZUG_MAXIMUM;

        assert_eq!(lastgang.to_string(), "1-0:1.29.0");
        assert_eq!(maximum.to_string(), "1-0:1.6.0");

        assert!(lastgang.is_lastgang() && !lastgang.is_maximum());
        assert!(maximum.is_maximum() && !maximum.is_lastgang());
        assert_ne!(lastgang, maximum);

        // The Lastgang is the 15-minute series; the Maximum is a single value
        // per billing period, so it has no interval resolution.
        use crate::resolution::IntervalResolution;
        assert_eq!(
            lastgang.default_resolution(),
            Some(IntervalResolution::QuarterHour)
        );
        assert_eq!(maximum.default_resolution(), None);
    }

    /// Blindleistung is C = 3…8, not just 3 and 4 — Q I…Q IV are C = 5…8.
    /// A quadrant register read as active energy puts kvarh in a kWh column.
    #[test]
    fn every_reactive_quadrant_is_reactive() {
        for c in 3..=8u8 {
            let code: ObisCode = format!("1-0:{c}.8.0").parse().unwrap();
            assert!(code.is_reactive(), "1-0:{c}.8.0 is Blindarbeit");
            assert!(!code.is_import(), "Blindarbeit is not Wirkarbeit Bezug");
        }
        for named in [
            ObisCode::STROM_BLINDARBEIT_POSITIV,
            ObisCode::STROM_BLINDARBEIT_NEGATIV,
            ObisCode::STROM_BLINDARBEIT_Q1,
            ObisCode::STROM_BLINDARBEIT_Q2,
            ObisCode::STROM_BLINDARBEIT_Q3,
            ObisCode::STROM_BLINDARBEIT_Q4,
        ] {
            assert!(named.is_reactive(), "{named}");
        }
        // ...and Wirkarbeit is not reactive.
        assert!(!ObisCode::STROM_BEZUG_TOTAL.is_reactive());
        assert!(!ObisCode::STROM_EINSPEISUNG_TOTAL.is_reactive());
    }

    /// The C group means something different per medium. Gas volume is
    /// `7-0:3.0.0`, and a C-only reactive check called it reactive energy.
    #[test]
    fn the_c_group_is_scoped_to_the_medium() {
        assert!(
            !ObisCode::GAS_VOLUME_M3.is_reactive(),
            "7-0:3.0.0 is a gas volume; C = 3 only means Blindleistung for A = 1"
        );
        assert!(ObisCode::GAS_VOLUME_M3.is_gas());

        // Nor is a gas or heat code an electricity direction.
        assert!(!ObisCode::GAS_VOLUME_M3.is_import());
        assert!(!ObisCode::WAERME_ENERGY.is_import());
    }

    /// E = 63 is the Fehlerregister, not tariff 63. Reporting it as a tariff
    /// invites a caller to bill a fault counter as consumption.
    #[test]
    fn fehlerregister_is_not_a_tariff() {
        let fehler: ObisCode = "1-0:1.8.63".parse().unwrap();
        assert!(fehler.is_fehlerregister());
        assert_eq!(fehler.tariff_register(), None);
        assert!(
            !fehler.is_total_register(),
            "E = 63 is not the total either"
        );
        assert_eq!(
            fehler.default_resolution(),
            None,
            "a fault counter is not a time series"
        );

        // Real tariffs still report themselves, across the post-2023 range.
        assert_eq!(ObisCode::STROM_BEZUG_HT.tariff_register(), Some(1));
        assert_eq!(ObisCode::STROM_BEZUG_NT.tariff_register(), Some(2));
        let t62: ObisCode = "1-0:1.8.62".parse().unwrap();
        assert_eq!(t62.tariff_register(), Some(62));
        assert!(!t62.is_fehlerregister());
        assert_eq!(ObisCode::STROM_BEZUG_TOTAL.tariff_register(), None);
    }
}

/// One channel, one string.
///
/// A parser that defaults the storage group to 255 and a `Display` that always
/// prints it give `"1-0:1.8.0"` and `"1-0:1.8.0*255"` for one channel. A
/// consumer keying stored rows on the string then sees two, and a correction
/// written through one spelling does not supersede the reading written through
/// the other.
#[cfg(test)]
mod canonical_string_tests {
    use super::*;

    /// Codes as MSCONS carries them and as people type them. Each must survive
    /// `parse` → `to_string` unchanged; that is the property a stored key needs.
    const CANONICAL: &[&str] = &[
        "1-0:1.8.0",
        "1-0:1.8.1",
        "1-0:1.8.2",
        "1-0:2.8.0",
        "1-0:2.8.1",
        "1-0:2.8.2",
        "1-0:1.29.0",
        "1-0:3.8.0",
        "1-0:4.8.0",
        "1-0:12.7.0",
        "7-0:3.0.0",
        "6-0:1.0.0",
        "5-0:1.0.0",
        "8-0:1.0.0",
        "9-0:1.0.0",
        "4-0:1.0.0",
        // A genuine billing-period register keeps its F group, so the suffix
        // survives wherever it carries information.
        "1-0:1.8.0*1",
        "1-0:1.8.0*0",
    ];

    #[test]
    fn canonical_strings_survive_a_round_trip() {
        for s in CANONICAL {
            let code: ObisCode = s.parse().unwrap_or_else(|e| panic!("{s}: {e}"));
            assert_eq!(&code.to_string(), s, "{s} is not string-stable");
        }
    }

    /// Two spellings, one merge key.
    #[test]
    fn both_spellings_are_one_value_and_one_string() {
        let typed: ObisCode = "1-0:1.8.0".parse().unwrap();
        let emitted: ObisCode = "1-0:1.8.0*255".parse().unwrap();

        assert_eq!(typed, emitted, "same channel, same value");
        assert_eq!(
            typed.to_string(),
            emitted.to_string(),
            "same channel, same key"
        );
        assert_eq!(typed.to_string(), "1-0:1.8.0");
    }

    /// Leading zeros and padding are accepted and normalised away, so an
    /// EDIFACT segment and a hand-typed cell land on the same key.
    #[test]
    fn lenient_spellings_normalise_onto_the_canonical_one() {
        for s in [
            "1-0:1.8.0",
            "1-0:1.8.0*255",
            "  1-0:1.8.0  ",
            "01-00:01.08.00",
            "1-0:01.8.0*0255",
        ] {
            assert_eq!(
                ObisCode::normalize(s).unwrap_or_else(|e| panic!("{s}: {e}")),
                "1-0:1.8.0",
                "{s} must normalise onto the canonical spelling"
            );
        }
    }

    #[test]
    fn normalize_is_idempotent() {
        for s in CANONICAL {
            let once = ObisCode::normalize(s).unwrap();
            assert_eq!(ObisCode::normalize(&once).unwrap(), once, "{s}");
        }
    }

    /// The alternate flag is the escape hatch for systems that demand an
    /// explicit F, and it round-trips to the same value.
    #[test]
    fn full_form_is_available_and_parses_back() {
        let code = ObisCode::STROM_BEZUG_TOTAL;
        assert_eq!(code.to_full_string(), "1-0:1.8.0*255");
        assert_eq!(format!("{code:#}"), "1-0:1.8.0*255");
        assert_eq!(code.to_full_string().parse::<ObisCode>().unwrap(), code);
    }

    /// A non-default storage group is information, so it is never elided —
    /// eliding it would merge two genuinely different registers.
    #[test]
    fn a_real_storage_group_is_never_elided() {
        let historical: ObisCode = "1-0:1.8.0*1".parse().unwrap();
        assert!(!historical.has_unused_storage());
        assert_eq!(historical.to_string(), "1-0:1.8.0*1");
        assert_ne!(historical, ObisCode::STROM_BEZUG_TOTAL);
        assert_ne!(
            historical.to_string(),
            ObisCode::STROM_BEZUG_TOTAL.to_string()
        );
    }

    /// A signed group is not a group. `u8::from_str` accepts `+1`, which would
    /// have let `+1-0:1.8.0*+255` in through the front door and back out under
    /// the canonical spelling.
    #[test]
    fn signed_and_empty_groups_are_rejected() {
        for s in [
            "+1-0:1.8.0",
            "1-0:1.8.0*+255",
            "1--0:1.8.0",
            "1-0:1.8.",
            "1-0:.8.0",
            "1-0:1.8.0*",
            "1-0:1.8.0.5",
            "1 - 0 : 1.8.0",
            "1-0:1.8.0*256",
            "256-0:1.8.0",
        ] {
            assert!(s.parse::<ObisCode>().is_err(), "{s:?} must not parse");
        }
    }

    /// Ordering follows the value groups, so a channel listing sorts the way a
    /// reader expects rather than by string bytes.
    #[test]
    fn ordering_is_by_value_group() {
        let mut codes = [
            ObisCode::GAS_VOLUME_M3,
            ObisCode::STROM_BEZUG_NT,
            ObisCode::STROM_BEZUG_TOTAL,
            ObisCode::STROM_BEZUG_HT,
        ];
        codes.sort();
        assert_eq!(
            codes,
            [
                ObisCode::STROM_BEZUG_TOTAL,
                ObisCode::STROM_BEZUG_HT,
                ObisCode::STROM_BEZUG_NT,
                ObisCode::GAS_VOLUME_M3,
            ]
        );
    }
}

#[cfg(test)]
mod media_group_tests {
    use super::*;

    /// The value-group-A media list from the DLMS/COSEM Blue Book, which OMS
    /// Spec Vol. 2 adopts.
    #[test]
    fn medium_group_a_follows_the_dlms_media_list() {
        let hca: ObisCode = "4-0:1.0.0".parse().unwrap();
        let cooling: ObisCode = "5-0:1.0.0".parse().unwrap();
        let heat: ObisCode = "6-0:1.0.0".parse().unwrap();
        let gas: ObisCode = "7-0:3.0.0".parse().unwrap();
        let cold_water: ObisCode = "8-0:1.0.0".parse().unwrap();
        let hot_water: ObisCode = "9-0:1.0.0".parse().unwrap();

        assert!(hca.is_heat_cost_allocator());
        assert!(
            !hca.is_heat(),
            "an HCA measures Verbrauchseinheiten, not kWh"
        );

        assert!(cooling.is_heat() && heat.is_heat());
        assert!(gas.is_gas() && !gas.is_heat());

        assert!(cold_water.is_water() && hot_water.is_water());
        assert!(!cold_water.is_heat(), "A=8 is cold water");
    }

    /// Regression: every named constant must satisfy the predicate its name
    /// implies. `WAERME_ENERGY` was A = 8, which is cold water — so a heat
    /// register reported `is_water()` and inherited water's daily resolution.
    #[test]
    fn named_constants_match_their_medium_predicate() {
        assert!(ObisCode::WAERME_ENERGY.is_heat(), "heat is medium 6");
        assert!(!ObisCode::WAERME_ENERGY.is_water());
        assert_eq!(ObisCode::WAERME_ENERGY.to_string(), "6-0:1.0.0");

        assert!(ObisCode::KAELTE_ENERGY.is_heat(), "cooling is medium 5");

        assert!(ObisCode::WASSER_KALT_VOLUME.is_water());
        assert!(!ObisCode::WASSER_KALT_VOLUME.is_heat());
        assert!(ObisCode::WASSER_WARM_VOLUME.is_water());

        assert!(ObisCode::GAS_VOLUME_M3.is_gas());
        assert!(ObisCode::STROM_BEZUG_TOTAL.is_electricity());

        // ...and the resolution follows the medium, not the name.
        use crate::resolution::IntervalResolution;
        assert_eq!(
            ObisCode::WAERME_ENERGY.default_resolution(),
            Some(IntervalResolution::Hour),
            "a heat meter is read hourly, not daily like a water submeter"
        );
        assert_eq!(
            ObisCode::WASSER_KALT_VOLUME.default_resolution(),
            Some(IntervalResolution::Day)
        );
    }

    /// Water submetering is read daily at best — never on a 15-minute grid.
    #[test]
    fn water_defaults_to_daily_resolution() {
        use crate::resolution::IntervalResolution;
        let cold_water: ObisCode = "8-0:1.0.0".parse().unwrap();
        let heat: ObisCode = "6-0:1.0.0".parse().unwrap();
        assert_eq!(
            cold_water.default_resolution(),
            Some(IntervalResolution::Day)
        );
        assert_eq!(heat.default_resolution(), Some(IntervalResolution::Hour));
    }
}

#[cfg(test)]
mod default_resolution_tests {
    use super::*;
    use crate::resolution::IntervalResolution as R;

    fn code(s: &str) -> ObisCode {
        s.parse().unwrap_or_else(|_| panic!("{s} must parse"))
    }

    /// A channel that is not an equidistant series has no resolution, and the
    /// answer must not depend on whether the Messgröße is active or reactive:
    /// `1-0:5.6.0` and `1-0:1.6.0` are the same Maximum register one Messgröße
    /// apart, and both have none.
    #[test]
    fn a_register_that_is_not_a_series_has_no_resolution() {
        for s in [
            "1-0:1.6.0",  // Wirkleistung Maximum
            "1-0:5.6.0",  // Blindleistung Q I Maximum
            "1-0:1.9.0",  // Vorschub — an arbitrary period
            "1-0:3.9.0",  // Blindarbeit Vorschub
            "1-0:1.7.0",  // Momentanwert
            "1-0:1.8.63", // Fehlerregister
            "4-0:1.0.0",  // Heizkostenverteiler — Verbrauchseinheiten
            "0-0:96.1.0", // an abstract code
        ] {
            assert_eq!(code(s).default_resolution(), None, "{s}");
        }
    }

    /// § 2 Satz 1 Nr. 27 MsbG: quarter-hourly for electricity, hourly for gas.
    #[test]
    fn the_series_channels_carry_the_msbg_cadences() {
        for s in ["1-0:1.8.0", "1-0:2.8.2", "1-0:1.29.0", "1-0:8.8.0"] {
            assert_eq!(code(s).default_resolution(), Some(R::QuarterHour), "{s}");
        }
        for s in ["7-0:3.0.0", "7-0:13.2.0"] {
            assert_eq!(code(s).default_resolution(), Some(R::Hour), "{s}");
        }
        assert_eq!(
            ObisCode::WAERME_ENERGY.default_resolution(),
            Some(R::Hour),
            "a heat meter delivers hourly"
        );
        assert_eq!(
            ObisCode::WASSER_KALT_VOLUME.default_resolution(),
            Some(R::Day),
            "water submetering is read daily at best"
        );
    }

    /// For the two gas conversion parameters, value group E **is** the
    /// averaging period. Reporting a monthly Brennwert as an hourly channel
    /// contradicted this file's own documentation of the same code.
    #[test]
    fn a_gas_mittelwert_takes_its_period_from_value_group_e() {
        assert_eq!(code("7-0:54.0.16").default_resolution(), Some(R::Hour));
        assert_eq!(code("7-0:54.0.20").default_resolution(), Some(R::Day));
        assert_eq!(
            ObisCode::GAS_BRENNWERT_MONATSMITTEL.default_resolution(),
            Some(R::Month),
        );
        assert_eq!(
            ObisCode::GAS_ZUSTANDSZAHL.default_resolution(),
            Some(R::Month),
        );
        // An E this crate cannot read as a period is not guessed at.
        assert_eq!(code("7-0:54.0.5").default_resolution(), None);
    }

    /// Whatever it answers, it never claims a length a calendar period does
    /// not have — the invariant `IntervalResolution` exists to hold.
    #[test]
    fn a_calendar_answer_never_claims_a_fixed_length() {
        for a in [0u8, 1, 4, 5, 6, 7, 8, 9] {
            for c in [1u8, 2, 3, 5, 8, 13, 52, 54, 99] {
                for d in [0u8, 2, 6, 7, 8, 9, 29] {
                    for e in [0u8, 1, 16, 20, 22, 63] {
                        let code = ObisCode {
                            a,
                            b: 0,
                            c,
                            d,
                            e,
                            f: ObisCode::STORAGE_UNUSED,
                        };
                        if let Some(r) = code.default_resolution() {
                            assert_eq!(
                                r.is_calendar(),
                                matches!(r, R::Day | R::Month | R::Year),
                                "{code}"
                            );
                            assert!(!matches!(r, R::Custom(_)), "{code} must not be Custom");
                        }
                    }
                }
            }
        }
    }
}