hems-flex
The household's flexibility, in the language Europe agreed on.
S2 — EN 50491-12-2 — is the interface between a Customer Energy Manager and the Resource Managers in a building. Its central idea is what makes it different from every protocol that came before:
A device describes what it can do, not what it is for.
A battery, a hot water tank and a parked car are all storage with a fill level. Once they say so in the same words, an energy manager can plan all three without knowing what any of them is — and a device that arrives next year works without a driver being written for it. EEBUS, by contrast, organises around named use cases, which is why it needs a new one for each new thing a device might do.
hems plans in S2's terms internally and speaks EEBUS where the German grid requires it. This crate is the first half.
The wire types come from s2energy,
generated from the official schema by the standard's own authors (TNO /
Flexiblepower). Writing our own would be a second opinion about a wire format,
which is the one thing a standard exists to prevent.
Which control type an asset belongs to
| Control type | For | hems assets |
|---|---|---|
| FRBC Fill Rate Based Control | a fill level and a rate | battery, hot water tank, a car with a departure time |
| PEBC Power Envelope Based Control | a bound is all that is needed | charge point, inverter curtailment, a heat pump that takes a ceiling |
| OMBC Operation Mode Based Control | discrete states | SG Ready heat pump, interruptible load |
| PPBC Power Profile Based Control | a fixed sequence started in a window | washing machine, dishwasher |
| DDBC Demand Driven Based Control | actuators serving a reported demand | — |
The choice follows from what the energy manager needs to be able to say, not
from the device class. A charge point with no departure time is a power envelope;
the same charge point with a car that must be full by seven is storage, with a
level, a rate and a target. Describing it as an envelope throws all three away.
That is why [control_type_for] takes the situation, not only the hardware.
What the descriptions get right
Three details that are easy to get wrong and expensive to get wrong:
- Round-trip losses live in the fill rate, not the power. 5 kW into a 95 % battery stores 4,75 kWh per hour. A manager planning on the electrical figure believes the battery is full a quarter of an hour early.
- Both battery modes start at idle. An
operation_mode_factorof zero stops whichever mode is active, so a manager that changes its mind never has to switch mode first — and never overshoots. - A charge point's envelope floor is its minimum current, not zero. Below 6 A a wallbox cannot operate at all; an envelope that says 0 invites a manager to allocate 2 kW and wonder why nothing charges.
A fourth, which only shows up on the second connection: the identifiers are derived, not generated. An instruction names an operation mode by ID, so a Resource Manager that re-mints its IDs on every reconnect invalidates every description the manager cached, and a manager replaying a ten-minute-old plan addresses modes that no longer exist. hems derives them (UUIDv5) from the asset's own identity, so a restart changes nothing.
And one that carries real money: consequence_type is DEFER for a wallbox and
VANISH for an inverter. Curtailed sunlight does not come back later. That single
field tells a manager it may throttle a car freely and must think twice about PV.
Reading an instruction back
An instruction is not a command: it names an operation mode by ID and gives a
factor in [0, 1]. Turning that into watts needs the description that was sent,
which is why every function here takes one. A mode we cannot name is a mode whose
power range we do not know, so it is refused rather than guessed.
let description = describe_battery;
// … send description.system to the CEM, receive an instruction …
let power = battery_power?;
Written, and reached
A flexibility model nothing imports is documentation, not a feature, and no
property test catches a module with no caller. So the reference day describes the
whole site in S2 and reports the count (described in S2: 5 resources — battery,
charge point, heat pump, hot-water tank, roof), and a test asserts that every
asset the arbiter can command has a control type and declares a role. A device
the S2 layer cannot describe is the first thing a real Resource Manager would
find, and better found here.