embedded-devices 0.10.3

Device driver implementations for many embedded sensors and devices
Documentation
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
//! The INA226 is a current shunt and power monitor with an I2C- or SMBUS-compatible interface.
//! The device monitors both a shunt voltage drop and bus supply voltage.
//! Programmable calibration value, conversion times, and averaging,combined with an
//! internal multiplier, enable direct readouts of current in amperes and power in watts.
//!
//! The INA226 senses current on common-mode bus voltages that can vary from 0V to 36V,
//! independent of the supply voltage. The device operates from a single 2.7V to 5.5V supply,
//! drawing a typical of 330μA of supply current. The device is specified over the
//! operating temperature range between –40°C and 125°C and features
//! up to 16 programmable addresses on the I2C-compatible interface.
//!
//! ## Usage (sync)
//!
//! ```rust
//! # #[cfg(feature = "sync")] mod test {
//! # fn test<I, D>(mut i2c: I, delay: D) -> Result<(), I::Error>
//! # where
//! #   I: embedded_hal::i2c::I2c + embedded_hal::i2c::ErrorType,
//! #   D: embedded_hal::delay::DelayNs
//! # {
//! use embedded_devices::devices::texas_instruments::ina226::{INA226Sync, address::Address, address::Pin};
//! use embedded_devices::sensor::OneshotSensorSync;
//! use uom::si::electric_current::{ampere, milliampere};
//! use uom::si::electric_potential::millivolt;
//! use uom::si::electrical_resistance::ohm;
//! use uom::si::power::milliwatt;
//! use uom::si::f64::{ElectricCurrent, ElectricalResistance};
//!
//! // Create and initialize the device
//! let mut ina226 = INA226Sync::new_i2c(delay, i2c, Address::A0A1(Pin::Gnd, Pin::Gnd));
//! ina226.init(
//!   // Most units use a 100mΩ shunt resistor
//!   ElectricalResistance::new::<ohm>(0.1),
//!   // Maximum expected current 3A
//!   ElectricCurrent::new::<ampere>(3.0),
//! ).unwrap();
//!
//! // One-shot read all values
//! let measurement = ina226.measure().unwrap();
//! let bus_voltage = measurement.bus_voltage.get::<millivolt>();
//! let current = measurement.current.get::<milliampere>();
//! let power = measurement.power.get::<milliwatt>();
//! println!("Current measurement: {:?}mV, {:?}mA, {:?}mW", bus_voltage, current, power);
//! # Ok(())
//! # }
//! # }
//! ```
//!
//! ## Usage (async)
//!
//! ```rust
//! # #[cfg(feature = "async")] mod test {
//! # async fn test<I, D>(mut i2c: I, delay: D) -> Result<(), I::Error>
//! # where
//! #   I: embedded_hal_async::i2c::I2c + embedded_hal_async::i2c::ErrorType,
//! #   D: embedded_hal_async::delay::DelayNs
//! # {
//! use embedded_devices::devices::texas_instruments::ina226::{INA226Async, address::Address, address::Pin};
//! use embedded_devices::sensor::OneshotSensorAsync;
//! use uom::si::electric_current::{ampere, milliampere};
//! use uom::si::electric_potential::millivolt;
//! use uom::si::electrical_resistance::ohm;
//! use uom::si::power::milliwatt;
//! use uom::si::f64::{ElectricCurrent, ElectricalResistance};
//!
//! // Create and initialize the device
//! let mut ina226 = INA226Async::new_i2c(delay, i2c, Address::A0A1(Pin::Gnd, Pin::Gnd));
//! ina226.init(
//!   // Most units use a 100mΩ shunt resistor
//!   ElectricalResistance::new::<ohm>(0.1),
//!   // Maximum expected current 3A
//!   ElectricCurrent::new::<ampere>(3.0),
//! ).await.unwrap();
//!
//! // One-shot read all values
//! let measurement = ina226.measure().await.unwrap();
//! let bus_voltage = measurement.bus_voltage.get::<millivolt>();
//! let current = measurement.current.get::<milliampere>();
//! let power = measurement.power.get::<milliwatt>();
//! println!("Current measurement: {:?}mV, {:?}mA, {:?}mW", bus_voltage, current, power);
//! # Ok(())
//! # }
//! # }
//! ```

use self::address::Address;

use embedded_devices_derive::{forward_register_fns, sensor};
use embedded_interfaces::TransportError;
use uom::si::electric_current::ampere;
use uom::si::electrical_resistance::ohm;
use uom::si::f64::{ElectricCurrent, ElectricPotential, ElectricalResistance, Power};

pub mod address;
pub mod registers;

#[cfg_attr(feature = "defmt", derive(defmt::Format))]
#[derive(Debug, thiserror::Error)]
pub enum InitError<BusError> {
    /// Transport error
    #[error("transport error")]
    Transport(#[from] TransportError<(), BusError>),
    /// Invalid Die Id was encountered
    #[error("invalid die id {0:#04x}")]
    InvalidDieId(u16),
    /// Invalid Manufacturer Id was encountered
    #[error("invalid manufacturer id {0:#04x}")]
    InvalidManufacturerId(u16),
}

#[derive(Debug, thiserror::Error)]
pub enum MeasurementError<BusError> {
    /// Transport error
    #[error("transport error")]
    Transport(#[from] TransportError<(), BusError>),
    /// The conversion ready flag was not set within the expected time frame.
    #[error("conversion timeout")]
    Timeout,
    /// Measurement was ready, but an overflow occurred. The power and
    /// current measurement may be incorrect.
    #[error("overflow in measurement")]
    Overflow(Measurement),
}

#[derive(Debug, thiserror::Error)]
pub enum ContinuousMeasurementError<BusError> {
    /// Transport error
    #[error("transport error")]
    Transport(#[from] TransportError<(), BusError>),
    /// Measurement was ready, but an overflow occurred. The power and
    /// current measurement may be incorrect.
    #[error("overflow in measurement")]
    Overflow(Measurement),
}

/// Measurement data
#[derive(Debug, embedded_devices_derive::Measurement)]
pub struct Measurement {
    /// Measured voltage across the shunt
    pub shunt_voltage: ElectricPotential,
    /// Measured voltage on the bus
    #[measurement(Voltage)]
    pub bus_voltage: ElectricPotential,
    /// Measured current
    #[measurement(Current)]
    pub current: ElectricCurrent,
    /// Measured power
    #[measurement(Power)]
    pub power: Power,
}

/// The INA226 is an ultra-precise digital power monitor with a 16-bit delta-sigma ADC
/// for high- or low-side current-sensing applications. The device can measure a full-scale
/// differential input of ±81.92 mV across a resistive shunt sense element with bus
/// voltage support from 0 V to +36 V.
///
/// For a full description and usage examples, refer to the [module documentation](self).
#[maybe_async_cfg::maybe(
    idents(hal(sync = "embedded_hal", async = "embedded_hal_async"), RegisterInterface),
    sync(feature = "sync"),
    async(feature = "async")
)]
pub struct INA226<D: hal::delay::DelayNs, I: embedded_interfaces::registers::RegisterInterface> {
    /// The delay provider
    delay: D,
    /// The interface to communicate with the device
    interface: I,
    /// Shunt resistance
    shunt_resistance: ElectricalResistance,
    /// Maximum expected current
    max_expected_current: ElectricCurrent,
    /// Configured nA/LSB for current readings
    current_lsb_na: i64,
}

pub trait INA226Register {}

#[maybe_async_cfg::maybe(
    idents(hal(sync = "embedded_hal", async = "embedded_hal_async"), I2cDevice),
    sync(feature = "sync"),
    async(feature = "async")
)]
impl<D, I> INA226<D, embedded_interfaces::i2c::I2cDevice<I, hal::i2c::SevenBitAddress>>
where
    I: hal::i2c::I2c<hal::i2c::SevenBitAddress> + hal::i2c::ErrorType,
    D: hal::delay::DelayNs,
{
    /// Initializes a new device with the given address on the specified bus.
    /// This consumes the I2C bus `I`.
    ///
    /// Before using this device, you should call the [`Self::init`] method which
    /// saves the calibration values to enable current and power output.
    #[inline]
    pub fn new_i2c(delay: D, interface: I, address: Address) -> Self {
        Self {
            delay,
            interface: embedded_interfaces::i2c::I2cDevice::new(interface, address.into()),
            shunt_resistance: Default::default(),
            max_expected_current: Default::default(),
            current_lsb_na: 1,
        }
    }
}

#[forward_register_fns]
#[sensor(Voltage, Current, Power)]
#[maybe_async_cfg::maybe(
    idents(
        hal(sync = "embedded_hal", async = "embedded_hal_async"),
        RegisterInterface,
        ResettableDevice
    ),
    sync(feature = "sync"),
    async(feature = "async")
)]
impl<D: hal::delay::DelayNs, I: embedded_interfaces::registers::RegisterInterface> INA226<D, I> {
    /// Soft-resets the device, calibrates it with the given shunt resistor
    /// value and maximum expected current.
    ///
    /// You can change the values later using [`Self::calibrate`].
    pub async fn init(
        &mut self,
        shunt_resistance: ElectricalResistance,
        max_expected_current: ElectricCurrent,
    ) -> Result<(), InitError<I::BusError>> {
        use crate::device::ResettableDevice;
        use registers::{DieId, ManufacturerId};

        // Reset the device and wait for 0.5ms. The datasheet does not define
        // a specific startup time so we use a similar value as the INA228.
        self.reset().await?;
        self.delay.delay_us(500).await;

        // Verify we are talking to the correct device
        let manufacturer_id = self.read_register::<ManufacturerId>().await?.read_id();
        if manufacturer_id != ManufacturerId::default().read_id() {
            return Err(InitError::InvalidManufacturerId(manufacturer_id));
        }
        let die_id = self.read_register::<DieId>().await?.read_id();
        if die_id != DieId::default().read_id() {
            return Err(InitError::InvalidDieId(die_id));
        }

        self.calibrate(shunt_resistance, max_expected_current).await?;

        Ok(())
    }

    /// Writes the given shunt resistance and maximum expected current into
    /// the device configuration register. This enables power and current output.
    pub async fn calibrate(
        &mut self,
        shunt_resistance: ElectricalResistance,
        max_expected_current: ElectricCurrent,
    ) -> Result<(), TransportError<(), I::BusError>> {
        self.shunt_resistance = shunt_resistance;
        self.max_expected_current = max_expected_current;

        let shunt_resistance = shunt_resistance.get::<ohm>();
        let max_expected_current = max_expected_current.get::<ampere>();

        self.current_lsb_na = ((1_000_000_000f64 / (1 << 15) as f64) * max_expected_current) as i64;
        let shunt_resistance_mohm = (1_000.0 * shunt_resistance) as i64;

        // Calibration Register = 0.00512 / (current_lsb (A) * shunt_resistance (Ω))
        let cal = 5_120_000_000 / (self.current_lsb_na * shunt_resistance_mohm);
        self.write_register(self::registers::Calibration::default().with_raw_value(cal as u16))
            .await?;

        Ok(())
    }

    /// Returns the currently stored measurement values without triggering a new measurement.
    /// A timeout error cannot occur here.
    pub async fn read_measurements(&mut self) -> Result<Measurement, MeasurementError<I::BusError>> {
        let bus_voltage = self.read_register::<self::registers::BusVoltage>().await?;
        let shunt_voltage = self.read_register::<self::registers::ShuntVoltage>().await?;
        let current = self.read_register::<self::registers::Current>().await?;
        let power = self.read_register::<self::registers::Power>().await?;
        let flags = self.read_register::<self::registers::MaskEnable>().await?;

        let measurement = Measurement {
            shunt_voltage: shunt_voltage.read_value(),
            bus_voltage: bus_voltage.read_value(),
            current: current.read_current(self.current_lsb_na),
            power: power.read_power(self.current_lsb_na),
        };

        if flags.read_math_overflow_flag() {
            Err(MeasurementError::Overflow(measurement))
        } else {
            Ok(measurement)
        }
    }
}

#[maybe_async_cfg::maybe(
    idents(
        hal(sync = "embedded_hal", async = "embedded_hal_async"),
        RegisterInterface,
        ResettableDevice
    ),
    sync(feature = "sync"),
    async(feature = "async")
)]
impl<D: hal::delay::DelayNs, I: embedded_interfaces::registers::RegisterInterface> crate::device::ResettableDevice
    for INA226<D, I>
{
    type Error = TransportError<(), I::BusError>;

    /// Performs a soft-reset of the device, restoring internal registers to power-on reset values.
    async fn reset(&mut self) -> Result<(), Self::Error> {
        self.write_register(self::registers::Configuration::default().with_reset(true))
            .await?;
        Ok(())
    }
}

#[maybe_async_cfg::maybe(
    idents(
        hal(sync = "embedded_hal", async = "embedded_hal_async"),
        RegisterInterface,
        OneshotSensor
    ),
    sync(feature = "sync"),
    async(feature = "async")
)]
impl<D: hal::delay::DelayNs, I: embedded_interfaces::registers::RegisterInterface> crate::sensor::OneshotSensor
    for INA226<D, I>
{
    type Error = MeasurementError<I::BusError>;
    type Measurement = Measurement;

    /// Performs a one-shot measurement. This will set the operating mode to
    /// [`self::registers::OperatingMode::ShuntAndBusTriggered`] and enable all conversion outputs causing the
    /// device to perform a single conversion a return to sleep afterwards.
    async fn measure(&mut self) -> Result<Self::Measurement, Self::Error> {
        let reg_conf = self.read_register::<self::registers::Configuration>().await?;

        // Initiate measurement
        self.write_register(reg_conf.with_operating_mode(self::registers::OperatingMode::ShuntAndBusTriggered))
            .await?;

        // Wait until measurement is ready, plus 10% and 1ms extra
        let mut measurement_time_us = reg_conf.total_conversion_time_us();
        measurement_time_us += measurement_time_us / 10; // 10% extra (data sheet conversion times state ~10% higher maximum times)
        self.delay.delay_us(1000 + measurement_time_us).await;

        // Wait for the conversion ready flag to be set
        const TRIES: u8 = 5;
        for _ in 0..TRIES {
            let flags = self.read_register::<self::registers::MaskEnable>().await?;
            if !flags.read_conversion_ready_flag() {
                self.delay.delay_us(1000).await;
                continue;
            }

            let bus_voltage = self.read_register::<self::registers::BusVoltage>().await?;
            let shunt_voltage = self.read_register::<self::registers::ShuntVoltage>().await?;
            let current = self.read_register::<self::registers::Current>().await?;
            // Reading this register clears the conversion_ready flag
            let power = self.read_register::<self::registers::Power>().await?;

            let measurement = Measurement {
                shunt_voltage: shunt_voltage.read_value(),
                bus_voltage: bus_voltage.read_value(),
                current: current.read_current(self.current_lsb_na),
                power: power.read_power(self.current_lsb_na),
            };

            if flags.read_math_overflow_flag() {
                return Err(MeasurementError::Overflow(measurement));
            } else {
                return Ok(measurement);
            }
        }

        Err(MeasurementError::Timeout)
    }
}

#[maybe_async_cfg::maybe(
    idents(
        hal(sync = "embedded_hal", async = "embedded_hal_async"),
        RegisterInterface,
        ContinuousSensor
    ),
    sync(feature = "sync"),
    async(feature = "async")
)]
impl<D: hal::delay::DelayNs, I: embedded_interfaces::registers::RegisterInterface> crate::sensor::ContinuousSensor
    for INA226<D, I>
{
    type Error = ContinuousMeasurementError<I::BusError>;
    type Measurement = Measurement;

    /// Starts continuous measurement.
    async fn start_measuring(&mut self) -> Result<(), Self::Error> {
        let reg_conf = self.read_register::<self::registers::Configuration>().await?;
        self.write_register(reg_conf.with_operating_mode(self::registers::OperatingMode::ShuntAndBusContinuous))
            .await?;
        Ok(())
    }

    /// Stops continuous measurement.
    async fn stop_measuring(&mut self) -> Result<(), Self::Error> {
        let reg_conf = self.read_register::<self::registers::Configuration>().await?;
        self.write_register(reg_conf.with_operating_mode(self::registers::OperatingMode::PowerDown))
            .await?;
        Ok(())
    }

    /// Expected amount of time between measurements in microseconds.
    async fn measurement_interval_us(&mut self) -> Result<u32, Self::Error> {
        let reg_conf = self.read_register::<self::registers::Configuration>().await?;
        let mut measurement_time_us = reg_conf.total_conversion_time_us();
        measurement_time_us += measurement_time_us / 10; // 10% extra (data sheet conversion times state ~10% higher maximum times)
        Ok(measurement_time_us)
    }

    /// Returns the most recent measurement. Will never return None.
    async fn current_measurement(&mut self) -> Result<Option<Self::Measurement>, Self::Error> {
        let flags = self.read_register::<self::registers::MaskEnable>().await?;
        let bus_voltage = self.read_register::<self::registers::BusVoltage>().await?;
        let shunt_voltage = self.read_register::<self::registers::ShuntVoltage>().await?;
        let current = self.read_register::<self::registers::Current>().await?;
        // Reading this register clears the conversion_ready flag
        let power = self.read_register::<self::registers::Power>().await?;

        let measurement = Measurement {
            shunt_voltage: shunt_voltage.read_value(),
            bus_voltage: bus_voltage.read_value(),
            current: current.read_current(self.current_lsb_na),
            power: power.read_power(self.current_lsb_na),
        };

        if flags.read_math_overflow_flag() {
            Err(ContinuousMeasurementError::Overflow(measurement))
        } else {
            Ok(Some(measurement))
        }
    }

    /// Check if new measurements are available.
    async fn is_measurement_ready(&mut self) -> Result<bool, Self::Error> {
        let flags = self.read_register::<self::registers::MaskEnable>().await?;
        Ok(flags.read_conversion_ready_flag())
    }

    /// Wait indefinitely until new measurements are available and return them. Checks whether data
    /// is ready in intervals of 100us.
    async fn next_measurement(&mut self) -> Result<Self::Measurement, Self::Error> {
        loop {
            let flags = self.read_register::<self::registers::MaskEnable>().await?;
            if flags.read_conversion_ready_flag() {
                let bus_voltage = self.read_register::<self::registers::BusVoltage>().await?;
                let shunt_voltage = self.read_register::<self::registers::ShuntVoltage>().await?;
                let current = self.read_register::<self::registers::Current>().await?;
                // Reading this register clears the conversion_ready flag
                let power = self.read_register::<self::registers::Power>().await?;

                let measurement = Measurement {
                    shunt_voltage: shunt_voltage.read_value(),
                    bus_voltage: bus_voltage.read_value(),
                    current: current.read_current(self.current_lsb_na),
                    power: power.read_power(self.current_lsb_na),
                };

                if flags.read_math_overflow_flag() {
                    return Err(ContinuousMeasurementError::Overflow(measurement));
                } else {
                    return Ok(measurement);
                }
            }

            self.delay.delay_us(100).await;
        }
    }
}