cimstructs/WindLookupTableFunctionKind.rs
1/// Function of the lookup table.
2#[derive(Debug, Clone, PartialEq, serde::Serialize, serde::Deserialize)]
3pub enum WindLookupTableFunctionKind {
4 /// Power versus speed change (negative slip) lookup table (prr(deltaomega)). It is used for the rotor resistance control model, IEC 61400-27-1:2015, 5.6.5.3.
5 prr,
6 /// Power vs. speed lookup table (omega(p)). It is used for the P control model type 3, IEC 61400-27-1:2015, 5.6.5.4.
7 omegap,
8 /// Lookup table for voltage dependency of active current limits (ipmax(uWT)). It is used for the current limitation model, IEC 61400-27-1:2015, 5.6.5.8.
9 ipmax,
10 /// Lookup table for voltage dependency of reactive current limits (iqmax(uWT)). It is used for the current limitation model, IEC 61400-27-1:2015, 5.6.5.8.
11 iqmax,
12 /// Power vs. frequency lookup table (pWPbias(f)). It is used for the wind power plant frequency and active power control model, IEC 61400-27-1:2015, Annex D.
13 pwp,
14 /// Crowbar duration versus voltage variation look-up table (TCW(du)). It is a case-dependent parameter. It is used for the type 3B generator set model, IEC 61400-27-1:2015, 5.6.3.3.
15 tcwdu,
16 /// Lookup table to determine the duration of the power reduction after a voltage dip, depending on the size of the voltage dip (Td(uWT)). It is a type-dependent parameter. It is used for the pitch control power model, IEC 61400-27-1:2015, 5.6.5.1.
17 tduwt,
18 /// Lookup table for active power dependency of reactive power maximum limit (qmaxp(p)). It is used for the QP and QU limitation model, IEC 61400-27-1:2015, 5.6.5.10.
19 qmaxp,
20 /// Lookup table for active power dependency of reactive power minimum limit (qminp(p)). It is used for the QP and QU limitation model, IEC 61400-27-1:2015, 5.6.5.10.
21 qminp,
22 /// Lookup table for voltage dependency of reactive power maximum limit (qmaxu(p)). It is used for the QP and QU limitation model, IEC 61400-27-1:2015, 5.6.5.10.
23 qmaxu,
24 /// Lookup table for voltage dependency of reactive power minimum limit (qminu(p)). It is used for the QP and QU limitation model, IEC 61400-27-1:2015, 5.6.5.10.
25 qminu,
26 /// Disconnection time versus over-voltage lookup table (Tuover(uWT)). It is used for the grid protection model, IEC 61400-27-1:2015, 5.6.6.
27 tuover,
28 /// Disconnection time versus under-voltage lookup table (Tuunder(uWT)). It is used for the grid protection model, IEC 61400-27-1:2015, 5.6.6.
29 tuunder,
30 /// Disconnection time versus over-frequency lookup table (Tfover(fWT)). It is used for the grid protection model, IEC 61400-27-1:2015, 5.6.6.
31 tfover,
32 /// Disconnection time versus under-frequency lookup table (Tfunder(fWT)). It is used for the grid protection model, IEC 61400-27-1:2015, 5.6.6.
33 tfunder,
34 /// Look up table for the UQ static mode (qWP(uerr)). It is used for the voltage and reactive power control model, IEC 61400-27-1:2015, Annex D.
35 qwp,
36}
37
38impl WindLookupTableFunctionKind {
39 pub fn uri(&self) -> &'static str {
40 match self {
41 WindLookupTableFunctionKind::prr => "http://iec.ch/TC57/CIM100#WindLookupTableFunctionKind.prr",
42 WindLookupTableFunctionKind::omegap => "http://iec.ch/TC57/CIM100#WindLookupTableFunctionKind.omegap",
43 WindLookupTableFunctionKind::ipmax => "http://iec.ch/TC57/CIM100#WindLookupTableFunctionKind.ipmax",
44 WindLookupTableFunctionKind::iqmax => "http://iec.ch/TC57/CIM100#WindLookupTableFunctionKind.iqmax",
45 WindLookupTableFunctionKind::pwp => "http://iec.ch/TC57/CIM100#WindLookupTableFunctionKind.pwp",
46 WindLookupTableFunctionKind::tcwdu => "http://iec.ch/TC57/CIM100#WindLookupTableFunctionKind.tcwdu",
47 WindLookupTableFunctionKind::tduwt => "http://iec.ch/TC57/CIM100#WindLookupTableFunctionKind.tduwt",
48 WindLookupTableFunctionKind::qmaxp => "http://iec.ch/TC57/CIM100#WindLookupTableFunctionKind.qmaxp",
49 WindLookupTableFunctionKind::qminp => "http://iec.ch/TC57/CIM100#WindLookupTableFunctionKind.qminp",
50 WindLookupTableFunctionKind::qmaxu => "http://iec.ch/TC57/CIM100#WindLookupTableFunctionKind.qmaxu",
51 WindLookupTableFunctionKind::qminu => "http://iec.ch/TC57/CIM100#WindLookupTableFunctionKind.qminu",
52 WindLookupTableFunctionKind::tuover => "http://iec.ch/TC57/CIM100#WindLookupTableFunctionKind.tuover",
53 WindLookupTableFunctionKind::tuunder => "http://iec.ch/TC57/CIM100#WindLookupTableFunctionKind.tuunder",
54 WindLookupTableFunctionKind::tfover => "http://iec.ch/TC57/CIM100#WindLookupTableFunctionKind.tfover",
55 WindLookupTableFunctionKind::tfunder => "http://iec.ch/TC57/CIM100#WindLookupTableFunctionKind.tfunder",
56 WindLookupTableFunctionKind::qwp => "http://iec.ch/TC57/CIM100#WindLookupTableFunctionKind.qwp",
57 }
58 }