1#![allow(clippy::all, dead_code)]
3
4use crate::base::{AttrDef, AttrKind, ClassDef, EnumDef, EnumValueDef, Schema};
5
6pub static CLASSES: &[ClassDef] = &[
8 ClassDef {
9 ns: "http://iec.ch/TC57/CIM100#",
10 local: "ACDCConverter",
11 qualified: "ACDCConverter",
12 super_class: Some(37),
13 concrete: false,
14 origins: &["EQ", "DY", "SSH", "SV"],
15 comment: "A unit with valves for three phases, together with unit control equipment, essential protective and switching devices, DC storage capacitors, phase reactors and auxiliaries, if any, used for conversion.",
16 attrs: &[
17 AttrDef { id: "ACDCConverter.DCTerminals", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ACDCConverterDCTerminal", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "A DC converter have DC converter terminals. A converter has two DC converter terminals." },
18 AttrDef { id: "ACDCConverter.PccTerminal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Terminal", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "Point of common coupling terminal for this converter DC side. It is typically the terminal on the power transformer (or switch) closest to the AC network." },
19 AttrDef { id: "ACDCConverter.baseS", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ApparentPower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Base apparent power of the converter pole. The attribute shall be a positive value." },
20 AttrDef { id: "ACDCConverter.idc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "CurrentFlow", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SV"], comment: "Converter DC current, also called Id. It is converter’s state variable, result from power flow." },
21 AttrDef { id: "ACDCConverter.idleLoss", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Active power loss in pole at no power transfer. It is converter’s configuration data used in power flow. The attribute shall be a positive value." },
22 AttrDef { id: "ACDCConverter.maxP", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Maximum active power limit. The value is overwritten by values of VsCapabilityCurve, if present." },
23 AttrDef { id: "ACDCConverter.maxUdc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The maximum voltage on the DC side at which the converter should operate. It is converter’s configuration data used in power flow. The attribute shall be a positive value." },
24 AttrDef { id: "ACDCConverter.minP", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Minimum active power limit. The value is overwritten by values of VsCapabilityCurve, if present." },
25 AttrDef { id: "ACDCConverter.minUdc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The minimum voltage on the DC side at which the converter should operate. It is converter’s configuration data used in power flow. The attribute shall be a positive value." },
26 AttrDef { id: "ACDCConverter.numberOfValves", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["EQ"], comment: "Number of valves in the converter. Used in loss calculations." },
27 AttrDef { id: "ACDCConverter.p", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Active power at the point of common coupling. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for a steady state solution in the case a simplified power flow model is used." },
28 AttrDef { id: "ACDCConverter.poleLossP", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SV"], comment: "The active power loss at a DC Pole = idleLoss + switchingLoss*|Idc| + resitiveLoss*Idc^2. For lossless operation Pdc=Pac. For rectifier operation with losses Pdc=Pac-lossP. For inverter operation with losses Pdc=Pac+lossP. It is converter’s state variable used in power flow. The attribute shall be a positive value." },
29 AttrDef { id: "ACDCConverter.q", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Reactive power at the point of common coupling. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for a steady state solution in the case a simplified power flow model is used." },
30 AttrDef { id: "ACDCConverter.ratedUdc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Rated converter DC voltage, also called UdN. The attribute shall be a positive value. It is converter’s configuration data used in power flow. For instance a bipolar HVDC link with value 200 kV has a 400kV difference between the dc lines." },
31 AttrDef { id: "ACDCConverter.resistiveLoss", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "It is converter’s configuration data used in power flow. Refer to poleLossP. The attribute shall be a positive value." },
32 AttrDef { id: "ACDCConverter.switchingLoss", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePowerPerCurrentFlow", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Switching losses, relative to the base apparent power 'baseS'. Refer to poleLossP. The attribute shall be a positive value." },
33 AttrDef { id: "ACDCConverter.targetPpcc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Real power injection target in AC grid, at point of common coupling. Load sign convention is used, i.e. positive sign means flow out from a node." },
34 AttrDef { id: "ACDCConverter.targetUdc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Target value for DC voltage magnitude. The attribute shall be a positive value." },
35 AttrDef { id: "ACDCConverter.uc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SV"], comment: "Line-to-line converter voltage, the voltage at the AC side of the valve. It is converter’s state variable, result from power flow. The attribute shall be a positive value." },
36 AttrDef { id: "ACDCConverter.udc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SV"], comment: "Converter voltage at the DC side, also called Ud. It is converter’s state variable, result from power flow. The attribute shall be a positive value." },
37 AttrDef { id: "ACDCConverter.valveU0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Valve threshold voltage, also called Uvalve. Forward voltage drop when the valve is conducting. Used in loss calculations, i.e. the switchLoss depend on numberOfValves * valveU0." },
38 ],
39 },
40 ClassDef {
41 ns: "http://iec.ch/TC57/CIM100#",
42 local: "ACDCConverterDCTerminal",
43 qualified: "ACDCConverterDCTerminal",
44 super_class: Some(56),
45 concrete: true,
46 origins: &["EQ", "SSH", "TP"],
47 comment: "A DC electrical connection point at the AC/DC converter. The AC/DC converter is electrically connected also to the AC side. The AC connection is inherited from the AC conducting equipment in the same way as any other AC equipment. The AC/DC converter DC terminal is separate from generic DC terminal to restrict the connection with the AC side to AC/DC converter and so that no other DC conducting equipment can be connected to the AC side.",
48 attrs: &[
49 AttrDef { id: "ACDCConverterDCTerminal.DCConductingEquipment", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ACDCConverter", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "A DC converter terminal belong to an DC converter." },
50 AttrDef { id: "ACDCConverterDCTerminal.polarity", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "DCPolarityKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "Represents the normal network polarity condition. Depending on the converter configuration the value shall be set as follows: - For a monopole with two converter terminals use DCPolarityKind “positive” and “negative”. - For a bi-pole or symmetric monopole with three converter terminals use DCPolarityKind “positive”, “middle” and “negative”." },
51 ],
52 },
53 ClassDef {
54 ns: "http://iec.ch/TC57/CIM100#",
55 local: "ACDCTerminal",
56 qualified: "ACDCTerminal",
57 super_class: Some(213),
58 concrete: false,
59 origins: &["EQ", "DY", "EQBD", "OP", "SC", "SSH", "SV", "TP"],
60 comment: "An electrical connection point (AC or DC) to a piece of conducting equipment. Terminals are connected at physical connection points called connectivity nodes.",
61 attrs: &[
62 AttrDef { id: "ACDCTerminal.BusNameMarker", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "BusNameMarker", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The bus name marker used to name the bus (topological node)." },
63 AttrDef { id: "ACDCTerminal.Measurements", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Measurement", is_list: true, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "Measurements associated with this terminal defining where the measurement is placed in the network topology. It may be used, for instance, to capture the sensor position, such as a voltage transformer (PT) at a busbar or a current transformer (CT) at the bar between a breaker and an isolator." },
64 AttrDef { id: "ACDCTerminal.OperationalLimitSet", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "OperationalLimitSet", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The operational limit sets at the terminal." },
65 AttrDef { id: "ACDCTerminal.connected", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["SSH"], comment: "The connected status is related to a bus-branch model and the topological node to terminal relation. True implies the terminal is connected to the related topological node and false implies it is not. In a bus-branch model, the connected status is used to tell if equipment is disconnected without having to change the connectivity described by the topological node to terminal relation. A valid case is that conducting equipment can be connected in one end and open in the other. In particular for an AC line segment, where the reactive line charging can be significant, this is a relevant case." },
66 AttrDef { id: "ACDCTerminal.sequenceNumber", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["EQ"], comment: "The orientation of the terminal connections for a multiple terminal conducting equipment. The sequence numbering starts with 1 and additional terminals should follow in increasing order. The first terminal is the 'starting point' for a two terminal branch." },
67 ],
68 },
69 ClassDef {
70 ns: "http://iec.ch/TC57/CIM100#",
71 local: "ACLineSegment",
72 qualified: "ACLineSegment",
73 super_class: Some(38),
74 concrete: true,
75 origins: &["EQ", "SC"],
76 comment: "A wire or combination of wires, with consistent electrical characteristics, building a single electrical system, used to carry alternating current between points in the power system. For symmetrical, transposed three phase lines, it is sufficient to use attributes of the line segment, which describe impedances and admittances for the entire length of the segment. Additionally impedances can be computed by using length and associated per length impedances. The BaseVoltage at the two ends of ACLineSegments in a Line shall have the same BaseVoltage.nominalVoltage. However, boundary lines may have slightly different BaseVoltage.nominalVoltages and variation is allowed. Larger voltage difference in general requires use of an equivalent branch.",
77 attrs: &[
78 AttrDef { id: "ACLineSegment.Clamp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Clamp", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The clamps connected to the line segment." },
79 AttrDef { id: "ACLineSegment.Cut", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Cut", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "Cuts applied to the line segment." },
80 AttrDef { id: "ACLineSegment.b0ch", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Susceptance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence shunt (charging) susceptance, uniformly distributed, of the entire line section." },
81 AttrDef { id: "ACLineSegment.bch", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Susceptance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Positive sequence shunt (charging) susceptance, uniformly distributed, of the entire line section. This value represents the full charging over the full length of the line." },
82 AttrDef { id: "ACLineSegment.g0ch", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Conductance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence shunt (charging) conductance, uniformly distributed, of the entire line section." },
83 AttrDef { id: "ACLineSegment.gch", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Conductance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Positive sequence shunt (charging) conductance, uniformly distributed, of the entire line section." },
84 AttrDef { id: "ACLineSegment.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Positive sequence series resistance of the entire line section." },
85 AttrDef { id: "ACLineSegment.r0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence series resistance of the entire line section." },
86 AttrDef { id: "ACLineSegment.shortCircuitEndTemperature", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Temperature", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Maximum permitted temperature at the end of SC for the calculation of minimum short-circuit currents. Used for short circuit data exchange according to IEC 60909." },
87 AttrDef { id: "ACLineSegment.x", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Positive sequence series reactance of the entire line section." },
88 AttrDef { id: "ACLineSegment.x0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence series reactance of the entire line section." },
89 ],
90 },
91 ClassDef {
92 ns: "http://iec.ch/TC57/CIM100#",
93 local: "Accumulator",
94 qualified: "Accumulator",
95 super_class: Some(233),
96 concrete: true,
97 origins: &["OP"],
98 comment: "Accumulator represents an accumulated (counted) Measurement, e.g. an energy value.",
99 attrs: &[
100 AttrDef { id: "Accumulator.AccumulatorValues", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "AccumulatorValue", is_list: true, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "The values connected to this measurement." },
101 AttrDef { id: "Accumulator.LimitSets", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "AccumulatorLimitSet", is_list: true, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "A measurement may have zero or more limit ranges defined for it." },
102 ],
103 },
104 ClassDef {
105 ns: "http://iec.ch/TC57/CIM100#",
106 local: "AccumulatorLimit",
107 qualified: "AccumulatorLimit",
108 super_class: Some(216),
109 concrete: true,
110 origins: &["OP"],
111 comment: "Limit values for Accumulator measurements.",
112 attrs: &[
113 AttrDef { id: "AccumulatorLimit.LimitSet", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "AccumulatorLimitSet", is_list: false, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "The set of limits." },
114 AttrDef { id: "AccumulatorLimit.value", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["OP"], comment: "The value to supervise against. The value is positive." },
115 ],
116 },
117 ClassDef {
118 ns: "http://iec.ch/TC57/CIM100#",
119 local: "AccumulatorLimitSet",
120 qualified: "AccumulatorLimitSet",
121 super_class: Some(218),
122 concrete: true,
123 origins: &["OP"],
124 comment: "An AccumulatorLimitSet specifies a set of Limits that are associated with an Accumulator measurement.",
125 attrs: &[
126 AttrDef { id: "AccumulatorLimitSet.Limits", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "AccumulatorLimit", is_list: true, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "The limit values used for supervision of Measurements." },
127 AttrDef { id: "AccumulatorLimitSet.Measurements", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Accumulator", is_list: true, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "The Measurements using the LimitSet." },
128 ],
129 },
130 ClassDef {
131 ns: "http://iec.ch/TC57/CIM100#",
132 local: "AccumulatorReset",
133 qualified: "AccumulatorReset",
134 super_class: Some(45),
135 concrete: true,
136 origins: &["OP"],
137 comment: "This command resets the counter value to zero.",
138 attrs: &[
139 AttrDef { id: "AccumulatorReset.AccumulatorValue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "AccumulatorValue", is_list: false, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "The accumulator value that is reset by the command." },
140 ],
141 },
142 ClassDef {
143 ns: "http://iec.ch/TC57/CIM100#",
144 local: "AccumulatorValue",
145 qualified: "AccumulatorValue",
146 super_class: Some(234),
147 concrete: true,
148 origins: &["OP"],
149 comment: "AccumulatorValue represents an accumulated (counted) MeasurementValue.",
150 attrs: &[
151 AttrDef { id: "AccumulatorValue.Accumulator", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Accumulator", is_list: false, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "Measurement to which this value is connected." },
152 AttrDef { id: "AccumulatorValue.AccumulatorReset", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "AccumulatorReset", is_list: false, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "The command that resets the accumulator value." },
153 ],
154 },
155 ClassDef {
156 ns: "http://iec.ch/TC57/CIM100#",
157 local: "ActivePowerLimit",
158 qualified: "ActivePowerLimit",
159 super_class: Some(248),
160 concrete: true,
161 origins: &["EQ", "SSH"],
162 comment: "Limit on active power flow.",
163 attrs: &[
164 AttrDef { id: "ActivePowerLimit.normalValue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The normal value of active power limit. The attribute shall be a positive value or zero." },
165 AttrDef { id: "ActivePowerLimit.value", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Value of active power limit. The attribute shall be a positive value or zero." },
166 ],
167 },
168 ClassDef {
169 ns: "http://iec.ch/TC57/CIM100#",
170 local: "Analog",
171 qualified: "Analog",
172 super_class: Some(233),
173 concrete: true,
174 origins: &["OP"],
175 comment: "Analog represents an analog Measurement.",
176 attrs: &[
177 AttrDef { id: "Analog.AnalogValues", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "AnalogValue", is_list: true, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "The values connected to this measurement." },
178 AttrDef { id: "Analog.LimitSets", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "AnalogLimitSet", is_list: true, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "A measurement may have zero or more limit ranges defined for it." },
179 AttrDef { id: "Analog.positiveFlowIn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["OP"], comment: "If true then this measurement is an active power, reactive power or current with the convention that a positive value measured at the Terminal means power is flowing into the related PowerSystemResource." },
180 ],
181 },
182 ClassDef {
183 ns: "http://iec.ch/TC57/CIM100#",
184 local: "AnalogControl",
185 qualified: "AnalogControl",
186 super_class: Some(45),
187 concrete: false,
188 origins: &["OP"],
189 comment: "An analog control used for supervisory control.",
190 attrs: &[
191 AttrDef { id: "AnalogControl.AnalogValue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "AnalogValue", is_list: false, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "The MeasurementValue that is controlled." },
192 AttrDef { id: "AnalogControl.maxValue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["OP"], comment: "Normal value range maximum for any of the Control.value. Used for scaling, e.g. in bar graphs." },
193 AttrDef { id: "AnalogControl.minValue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["OP"], comment: "Normal value range minimum for any of the Control.value. Used for scaling, e.g. in bar graphs." },
194 ],
195 },
196 ClassDef {
197 ns: "http://iec.ch/TC57/CIM100#",
198 local: "AnalogLimit",
199 qualified: "AnalogLimit",
200 super_class: Some(216),
201 concrete: true,
202 origins: &["OP"],
203 comment: "Limit values for Analog measurements.",
204 attrs: &[
205 AttrDef { id: "AnalogLimit.LimitSet", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "AnalogLimitSet", is_list: false, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "The set of limits." },
206 AttrDef { id: "AnalogLimit.value", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["OP"], comment: "The value to supervise against." },
207 ],
208 },
209 ClassDef {
210 ns: "http://iec.ch/TC57/CIM100#",
211 local: "AnalogLimitSet",
212 qualified: "AnalogLimitSet",
213 super_class: Some(218),
214 concrete: true,
215 origins: &["OP"],
216 comment: "An AnalogLimitSet specifies a set of Limits that are associated with an Analog measurement.",
217 attrs: &[
218 AttrDef { id: "AnalogLimitSet.Limits", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "AnalogLimit", is_list: true, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "The limit values used for supervision of Measurements." },
219 AttrDef { id: "AnalogLimitSet.Measurements", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Analog", is_list: true, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "The Measurements using the LimitSet." },
220 ],
221 },
222 ClassDef {
223 ns: "http://iec.ch/TC57/CIM100#",
224 local: "AnalogValue",
225 qualified: "AnalogValue",
226 super_class: Some(234),
227 concrete: true,
228 origins: &["OP"],
229 comment: "AnalogValue represents an analog MeasurementValue.",
230 attrs: &[
231 AttrDef { id: "AnalogValue.Analog", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Analog", is_list: false, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "Measurement to which this value is connected." },
232 AttrDef { id: "AnalogValue.AnalogControl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "AnalogControl", is_list: false, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "The Control variable associated with the MeasurementValue." },
233 ],
234 },
235 ClassDef {
236 ns: "http://iec.ch/TC57/CIM100#",
237 local: "ApparentPowerLimit",
238 qualified: "ApparentPowerLimit",
239 super_class: Some(248),
240 concrete: true,
241 origins: &["EQ", "SSH"],
242 comment: "Apparent power limit.",
243 attrs: &[
244 AttrDef { id: "ApparentPowerLimit.normalValue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ApparentPower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The normal apparent power limit. The attribute shall be a positive value or zero." },
245 AttrDef { id: "ApparentPowerLimit.value", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ApparentPower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "The apparent power limit. The attribute shall be a positive value or zero." },
246 ],
247 },
248 ClassDef {
249 ns: "http://iec.ch/TC57/CIM100#",
250 local: "AsynchronousMachine",
251 qualified: "AsynchronousMachine",
252 super_class: Some(320),
253 concrete: true,
254 origins: &["EQ", "DY", "SC", "SSH"],
255 comment: "A rotating machine whose shaft rotates asynchronously with the electrical field. Also known as an induction machine with no external connection to the rotor windings, e.g. squirrel-cage induction machine.",
256 attrs: &[
257 AttrDef { id: "AsynchronousMachine.AsynchronousMachineDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "AsynchronousMachineDynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Asynchronous machine dynamics model used to describe dynamic behaviour of this asynchronous machine." },
258 AttrDef { id: "AsynchronousMachine.asynchronousMachineType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "AsynchronousMachineKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["SSH"], comment: "Indicates the type of Asynchronous Machine (motor or generator)." },
259 AttrDef { id: "AsynchronousMachine.converterFedDrive", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["SC"], comment: "Indicates whether the machine is a converter fed drive. Used for short circuit data exchange according to IEC 60909." },
260 AttrDef { id: "AsynchronousMachine.efficiency", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PerCent", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Efficiency of the asynchronous machine at nominal operation as a percentage. Indicator for converter drive motors. Used for short circuit data exchange according to IEC 60909." },
261 AttrDef { id: "AsynchronousMachine.iaIrRatio", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Ratio of locked-rotor current to the rated current of the motor (Ia/Ir). Used for short circuit data exchange according to IEC 60909." },
262 AttrDef { id: "AsynchronousMachine.nominalFrequency", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Nameplate data indicates if the machine is 50 Hz or 60 Hz." },
263 AttrDef { id: "AsynchronousMachine.nominalSpeed", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "RotationSpeed", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Nameplate data. Depends on the slip and number of pole pairs." },
264 AttrDef { id: "AsynchronousMachine.polePairNumber", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["SC"], comment: "Number of pole pairs of stator. Used for short circuit data exchange according to IEC 60909." },
265 AttrDef { id: "AsynchronousMachine.ratedMechanicalPower", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Rated mechanical power (Pr in IEC 60909-0). Used for short circuit data exchange according to IEC 60909." },
266 AttrDef { id: "AsynchronousMachine.reversible", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["SC"], comment: "Indicates for converter drive motors if the power can be reversible. Used for short circuit data exchange according to IEC 60909." },
267 AttrDef { id: "AsynchronousMachine.rxLockedRotorRatio", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Locked rotor ratio (R/X). Used for short circuit data exchange according to IEC 60909." },
268 ],
269 },
270 ClassDef {
271 ns: "http://iec.ch/TC57/CIM100#",
272 local: "AsynchronousMachineDynamics",
273 qualified: "AsynchronousMachineDynamics",
274 super_class: Some(321),
275 concrete: false,
276 origins: &["DY"],
277 comment: "Asynchronous machine whose behaviour is described by reference to a standard model expressed in either time constant reactance form or equivalent circuit form or by definition of a user-defined model. Parameter details: Asynchronous machine parameters such as Xl, Xs, etc. are actually used as inductances in the model, but are commonly referred to as reactances since, at nominal frequency, the PU values are the same. However, some references use the symbol L instead of X.",
278 attrs: &[
279 AttrDef { id: "AsynchronousMachineDynamics.AsynchronousMachine", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "AsynchronousMachine", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Asynchronous machine to which this asynchronous machine dynamics model applies." },
280 AttrDef { id: "AsynchronousMachineDynamics.MechanicalLoadDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "MechanicalLoadDynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Mechanical load model associated with this asynchronous machine model." },
281 AttrDef { id: "AsynchronousMachineDynamics.TurbineGovernorDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TurbineGovernorDynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Turbine-governor model associated with this asynchronous machine model." },
282 AttrDef { id: "AsynchronousMachineDynamics.WindTurbineType1or2Dynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType1or2Dynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind generator type 1 or type 2 model associated with this asynchronous machine model." },
283 ],
284 },
285 ClassDef {
286 ns: "http://iec.ch/TC57/CIM100#",
287 local: "AsynchronousMachineEquivalentCircuit",
288 qualified: "AsynchronousMachineEquivalentCircuit",
289 super_class: Some(17),
290 concrete: true,
291 origins: &["DY"],
292 comment: "The electrical equations of all variations of the asynchronous model are based on the AsynchronousEquivalentCircuit diagram for the direct- and quadrature- axes, with two equivalent rotor windings in each axis. Equations for conversion between equivalent circuit and time constant reactance forms: Xs = Xm + Xl X' = Xl + Xm x Xlr1 / (Xm + Xlr1) X'' = Xl + Xm x Xlr1 x Xlr2 / (Xm x Xlr1 + Xm x Xlr2 + Xlr1 x Xlr2) T'o = (Xm + Xlr1) / (omega0 x Rr1) T''o = (Xm x Xlr1 + Xm x Xlr2 + Xlr1 x Xlr2) / (omega0 x Rr2 x (Xm + Xlr1) Same equations using CIM attributes from AsynchronousMachineTimeConstantReactance class on left of '=' and AsynchronousMachineEquivalentCircuit class on right (except as noted): xs = xm + RotatingMachineDynamics.statorLeakageReactance xp = RotatingMachineDynamics.statorLeakageReactance + xm x xlr1 / (xm + xlr1) xpp = RotatingMachineDynamics.statorLeakageReactance + xm x xlr1 x xlr2 / (xm x xlr1 + xm x xlr2 + xlr1 x xlr2) tpo = (xm + xlr1) / (2 x pi x nominal frequency x rr1) tppo = (xm x xlr1 + xm x xlr2 + xlr1 x xlr2) / (2 x pi x nominal frequency x rr2 x (xm + xlr1).",
293 attrs: &[
294 AttrDef { id: "AsynchronousMachineEquivalentCircuit.rr1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Damper 1 winding resistance." },
295 AttrDef { id: "AsynchronousMachineEquivalentCircuit.rr2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Damper 2 winding resistance." },
296 AttrDef { id: "AsynchronousMachineEquivalentCircuit.xlr1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Damper 1 winding leakage reactance." },
297 AttrDef { id: "AsynchronousMachineEquivalentCircuit.xlr2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Damper 2 winding leakage reactance." },
298 AttrDef { id: "AsynchronousMachineEquivalentCircuit.xm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Magnetizing reactance." },
299 ],
300 },
301 ClassDef {
302 ns: "http://iec.ch/TC57/CIM100#",
303 local: "AsynchronousMachineTimeConstantReactance",
304 qualified: "AsynchronousMachineTimeConstantReactance",
305 super_class: Some(17),
306 concrete: true,
307 origins: &["DY"],
308 comment: "Parameter details: If X'' = X', a single cage (one equivalent rotor winding per axis) is modelled. The “p” in the attribute names is a substitution for a “prime” in the usual parameter notation, e.g. tpo refers to T'o. The parameters used for models expressed in time constant reactance form include: - RotatingMachine.ratedS (MVAbase); - RotatingMachineDynamics.damping (D); - RotatingMachineDynamics.inertia (H); - RotatingMachineDynamics.saturationFactor (S1); - RotatingMachineDynamics.saturationFactor120 (S12); - RotatingMachineDynamics.statorLeakageReactance (Xl); - RotatingMachineDynamics.statorResistance (Rs); - .xs (Xs); - .xp (X'); - .xpp (X''); - .tpo (T'o); - .tppo (T''o).",
309 attrs: &[
310 AttrDef { id: "AsynchronousMachineTimeConstantReactance.tpo", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Transient rotor time constant (T'o) (> AsynchronousMachineTimeConstantReactance.tppo). Typical value = 5." },
311 AttrDef { id: "AsynchronousMachineTimeConstantReactance.tppo", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Subtransient rotor time constant (T''o) (> 0). Typical value = 0,03." },
312 AttrDef { id: "AsynchronousMachineTimeConstantReactance.xp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Transient reactance (unsaturated) (X') (>= AsynchronousMachineTimeConstantReactance.xpp). Typical value = 0,5." },
313 AttrDef { id: "AsynchronousMachineTimeConstantReactance.xpp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Subtransient reactance (unsaturated) (X'') (> RotatingMachineDynamics.statorLeakageReactance). Typical value = 0,2." },
314 AttrDef { id: "AsynchronousMachineTimeConstantReactance.xs", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Synchronous reactance (Xs) (>= AsynchronousMachineTimeConstantReactance.xp). Typical value = 1,8." },
315 ],
316 },
317 ClassDef {
318 ns: "http://iec.ch/TC57/CIM100#",
319 local: "AsynchronousMachineUserDefined",
320 qualified: "AsynchronousMachineUserDefined",
321 super_class: Some(17),
322 concrete: true,
323 origins: &["DY"],
324 comment: "Asynchronous machine whose dynamic behaviour is described by a user-defined model.",
325 attrs: &[
326 AttrDef { id: "AsynchronousMachineUserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
327 AttrDef { id: "AsynchronousMachineUserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
328 ],
329 },
330 ClassDef {
331 ns: "http://iec.ch/TC57/CIM100#",
332 local: "AuxiliaryEquipment",
333 qualified: "AuxiliaryEquipment",
334 super_class: Some(98),
335 concrete: false,
336 origins: &["EQ"],
337 comment: "AuxiliaryEquipment describe equipment that is not performing any primary functions but support for the equipment performing the primary function. AuxiliaryEquipment is attached to primary equipment via an association with Terminal.",
338 attrs: &[
339 AttrDef { id: "AuxiliaryEquipment.Terminal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Terminal", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The Terminal at the equipment where the AuxiliaryEquipment is attached." },
340 ],
341 },
342 ClassDef {
343 ns: "http://iec.ch/TC57/CIM100#",
344 local: "BaseVoltage",
345 qualified: "BaseVoltage",
346 super_class: Some(213),
347 concrete: true,
348 origins: &["EQ", "EQBD", "TP"],
349 comment: "Defines a system base voltage which is referenced.",
350 attrs: &[
351 AttrDef { id: "BaseVoltage.ConductingEquipment", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ConductingEquipment", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "All conducting equipment with this base voltage. Use only when there is no voltage level container used and only one base voltage applies. For example, not used for transformers." },
352 AttrDef { id: "BaseVoltage.TopologicalNode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TopologicalNode", is_list: true, used: false, xsd: "", value_ns: "", origins: &["TP"], comment: "The topological nodes at the base voltage." },
353 AttrDef { id: "BaseVoltage.TransformerEnds", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TransformerEnd", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "Transformer ends at the base voltage. This is essential for PU calculation." },
354 AttrDef { id: "BaseVoltage.VoltageLevel", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "VoltageLevel", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "The voltage levels having this base voltage." },
355 AttrDef { id: "BaseVoltage.nominalVoltage", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ", "EQBD"], comment: "The power system resource's base voltage. Shall be a positive value and not zero." },
356 ],
357 },
358 ClassDef {
359 ns: "http://iec.ch/TC57/CIM100#",
360 local: "BasicIntervalSchedule",
361 qualified: "BasicIntervalSchedule",
362 super_class: Some(213),
363 concrete: false,
364 origins: &["EQ"],
365 comment: "Schedule of values at points in time.",
366 attrs: &[
367 AttrDef { id: "BasicIntervalSchedule.startTime", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "DateTime", is_list: false, used: true, xsd: "dateTime", value_ns: "", origins: &["EQ"], comment: "The time for the first time point. The value can be a time of day, not a specific date." },
368 AttrDef { id: "BasicIntervalSchedule.value1Unit", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "UnitSymbol", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "Value1 units of measure." },
369 AttrDef { id: "BasicIntervalSchedule.value2Unit", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "UnitSymbol", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "Value2 units of measure." },
370 ],
371 },
372 ClassDef {
373 ns: "http://iec.ch/TC57/CIM100#",
374 local: "BatteryUnit",
375 qualified: "BatteryUnit",
376 super_class: Some(280),
377 concrete: true,
378 origins: &["EQ", "SSH"],
379 comment: "An electrochemical energy storage device.",
380 attrs: &[
381 AttrDef { id: "BatteryUnit.batteryState", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "BatteryStateKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["SSH"], comment: "The current state of the battery (charging, full, etc.)." },
382 AttrDef { id: "BatteryUnit.ratedE", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "RealEnergy", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Full energy storage capacity of the battery. The attribute shall be a positive value." },
383 AttrDef { id: "BatteryUnit.storedE", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "RealEnergy", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Amount of energy currently stored. The attribute shall be a positive value or zero and lower than BatteryUnit.ratedE." },
384 ],
385 },
386 ClassDef {
387 ns: "http://iec.ch/TC57/CIM100#",
388 local: "Bay",
389 qualified: "Bay",
390 super_class: Some(99),
391 concrete: true,
392 origins: &["EQ", "EQBD"],
393 comment: "A collection of power system resources (within a given substation) including conducting equipment, protection relays, measurements, and telemetry. A bay typically represents a physical grouping related to modularization of equipment.",
394 attrs: &[
395 AttrDef { id: "Bay.VoltageLevel", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "VoltageLevel", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "The voltage level containing this bay." },
396 ],
397 },
398 ClassDef {
399 ns: "http://iec.ch/TC57/CIM100-European#",
400 local: "BoundaryPoint",
401 qualified: "BoundaryPoint",
402 super_class: Some(282),
403 concrete: true,
404 origins: &["EQ", "EQBD"],
405 comment: "Designates a connection point at which one or more model authority sets shall connect to. The location of the connection point as well as other properties are agreed between organisations responsible for the interconnection, hence all attributes of the class represent this agreement. It is primarily used in a boundary model authority set which can contain one or many BoundaryPoint-s among other Equipment-s and their connections.",
406 attrs: &[
407 AttrDef { id: "BoundaryPoint.ConnectivityNode", ns: "http://iec.ch/TC57/CIM100-European#", kind: AttrKind::Association, range: "ConnectivityNode", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "The connectivity node that is designated as a boundary point." },
408 AttrDef { id: "BoundaryPoint.fromEndIsoCode", ns: "http://iec.ch/TC57/CIM100-European#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["EQ", "EQBD"], comment: "The ISO code of the region which the 'From' side of the Boundary point belongs to or it is connected to. The ISO code is a two-character country code as defined by ISO 3166 (http://www.iso.org/iso/country_codes). The length of the string is 2 characters maximum." },
409 AttrDef { id: "BoundaryPoint.fromEndName", ns: "http://iec.ch/TC57/CIM100-European#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["EQ", "EQBD"], comment: "A human readable name with length of the string 64 characters maximum. It covers the following two cases: -if the Boundary point is placed on a tie-line, it is the name (IdentifiedObject.name) of the substation at which the 'From' side of the tie-line is connected to. -if the Boundary point is placed in a substation, it is the name (IdentifiedObject.name) of the element (e.g. PowerTransformer, ACLineSegment, Switch, etc.) at which the 'From' side of the Boundary point is connected to." },
410 AttrDef { id: "BoundaryPoint.fromEndNameTso", ns: "http://iec.ch/TC57/CIM100-European#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["EQ", "EQBD"], comment: "Identifies the name of the transmission system operator, distribution system operator or other entity at which the 'From' side of the interconnection is connected to. The length of the string is 64 characters maximum." },
411 AttrDef { id: "BoundaryPoint.isDirectCurrent", ns: "http://iec.ch/TC57/CIM100-European#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["EQ", "EQBD"], comment: "If true, this boundary point is a point of common coupling (PCC) of a direct current (DC) interconnection, otherwise the interconnection is AC (default)." },
412 AttrDef { id: "BoundaryPoint.isExcludedFromAreaInterchange", ns: "http://iec.ch/TC57/CIM100-European#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["EQ", "EQBD"], comment: "If true, this boundary point is on the interconnection that is excluded from control area interchange calculation and consequently has no related tie flows. Otherwise, the interconnection is included in control area interchange and a TieFlow is required at all sides of the boundary point (default)." },
413 AttrDef { id: "BoundaryPoint.toEndIsoCode", ns: "http://iec.ch/TC57/CIM100-European#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["EQ", "EQBD"], comment: "The ISO code of the region which the 'To' side of the Boundary point belongs to or is connected to. The ISO code is a two-character country code as defined by ISO 3166 (http://www.iso.org/iso/country_codes). The length of the string is 2 characters maximum." },
414 AttrDef { id: "BoundaryPoint.toEndName", ns: "http://iec.ch/TC57/CIM100-European#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["EQ", "EQBD"], comment: "A human readable name with length of the string 64 characters maximum. It covers the following two cases: -if the Boundary point is placed on a tie-line, it is the name (IdentifiedObject.name) of the substation at which the 'To' side of the tie-line is connected to. -if the Boundary point is placed in a substation, it is the name (IdentifiedObject.name) of the element (e.g. PowerTransformer, ACLineSegment, Switch, etc.) at which the 'To' side of the Boundary point is connected to." },
415 AttrDef { id: "BoundaryPoint.toEndNameTso", ns: "http://iec.ch/TC57/CIM100-European#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["EQ", "EQBD"], comment: "Identifies the name of the transmission system operator, distribution system operator or other entity at which the 'To' side of the interconnection is connected to. The length of the string is 64 characters maximum." },
416 ],
417 },
418 ClassDef {
419 ns: "http://iec.ch/TC57/CIM100#",
420 local: "Breaker",
421 qualified: "Breaker",
422 super_class: Some(288),
423 concrete: true,
424 origins: &["EQ", "SSH"],
425 comment: "A mechanical switching device capable of making, carrying, and breaking currents under normal circuit conditions and also making, carrying for a specified time, and breaking currents under specified abnormal circuit conditions e.g. those of short circuit.",
426 attrs: &[],
427 },
428 ClassDef {
429 ns: "http://iec.ch/TC57/CIM100#",
430 local: "BusNameMarker",
431 qualified: "BusNameMarker",
432 super_class: Some(213),
433 concrete: true,
434 origins: &["EQ"],
435 comment: "Used to apply user standard names to TopologicalNodes. Associated with one or more terminals that are normally connected with the bus name. The associated terminals are normally connected by non-retained switches. For a ring bus station configuration, all BusbarSection terminals in the ring are typically associated. For a breaker and a half scheme, both BusbarSections would normally be associated. For a ring bus, all BusbarSections would normally be associated. For a 'straight' busbar configuration, normally only the main terminal at the BusbarSection would be associated.",
436 attrs: &[
437 AttrDef { id: "BusNameMarker.ReportingGroup", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ReportingGroup", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The reporting group to which this bus name marker belongs." },
438 AttrDef { id: "BusNameMarker.Terminal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ACDCTerminal", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The terminals associated with this bus name marker." },
439 AttrDef { id: "BusNameMarker.priority", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["EQ"], comment: "Priority of bus name marker for use as topology bus name. Use 0 for do not care. Use 1 for highest priority. Use 2 as priority is less than 1 and so on." },
440 ],
441 },
442 ClassDef {
443 ns: "http://iec.ch/TC57/CIM100#",
444 local: "BusbarSection",
445 qualified: "BusbarSection",
446 super_class: Some(44),
447 concrete: true,
448 origins: &["EQ", "SC"],
449 comment: "A conductor, or group of conductors, with negligible impedance, that serve to connect other conducting equipment within a single substation. Voltage measurements are typically obtained from voltage transformers that are connected to busbar sections. A bus bar section may have many physical terminals but for analysis is modelled with exactly one logical terminal.",
450 attrs: &[
451 AttrDef { id: "BusbarSection.ipMax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "CurrentFlow", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Maximum allowable peak short-circuit current of busbar (Ipmax in IEC 60909-0). Mechanical limit of the busbar in the substation itself. Used for short circuit data exchange according to IEC 60909." },
452 ],
453 },
454 ClassDef {
455 ns: "http://iec.ch/TC57/CIM100#",
456 local: "CAESPlant",
457 qualified: "CAESPlant",
458 super_class: Some(282),
459 concrete: true,
460 origins: &["EQ"],
461 comment: "Compressed air energy storage plant.",
462 attrs: &[
463 AttrDef { id: "CAESPlant.ThermalGeneratingUnit", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ThermalGeneratingUnit", is_list: false, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "A thermal generating unit may be a member of a compressed air energy storage plant." },
464 ],
465 },
466 ClassDef {
467 ns: "http://iec.ch/TC57/CIM100#",
468 local: "CSCDynamics",
469 qualified: "CSCDynamics",
470 super_class: Some(208),
471 concrete: false,
472 origins: &["DY"],
473 comment: "CSC function block whose behaviour is described by reference to a standard model or by definition of a user-defined model.",
474 attrs: &[
475 AttrDef { id: "CSCDynamics.CSConverter", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "CsConverter", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Current source converter to which current source converter dynamics model applies." },
476 ],
477 },
478 ClassDef {
479 ns: "http://iec.ch/TC57/CIM100#",
480 local: "CSCUserDefined",
481 qualified: "CSCUserDefined",
482 super_class: Some(31),
483 concrete: true,
484 origins: &["DY"],
485 comment: "Current source converter (CSC) function block whose dynamic behaviour is described by a user-defined model.",
486 attrs: &[
487 AttrDef { id: "CSCUserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
488 AttrDef { id: "CSCUserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
489 ],
490 },
491 ClassDef {
492 ns: "http://iec.ch/TC57/CIM100#",
493 local: "Clamp",
494 qualified: "Clamp",
495 super_class: Some(37),
496 concrete: true,
497 origins: &["EQ"],
498 comment: "A Clamp is a galvanic connection at a line segment where other equipment is connected. A Clamp does not cut the line segment. A Clamp is ConductingEquipment and has one Terminal with an associated ConnectivityNode. Any other ConductingEquipment can be connected to the Clamp ConnectivityNode.",
499 attrs: &[
500 AttrDef { id: "Clamp.ACLineSegment", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ACLineSegment", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The line segment to which the clamp is connected." },
501 AttrDef { id: "Clamp.lengthFromTerminal1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Length", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The length to the place where the clamp is located starting from side one of the line segment, i.e. the line segment terminal with sequence number equal to 1." },
502 ],
503 },
504 ClassDef {
505 ns: "http://iec.ch/TC57/CIM100#",
506 local: "CogenerationPlant",
507 qualified: "CogenerationPlant",
508 super_class: Some(282),
509 concrete: true,
510 origins: &["EQ"],
511 comment: "A set of thermal generating units for the production of electrical energy and process steam (usually from the output of the steam turbines). The steam sendout is typically used for industrial purposes or for municipal heating and cooling.",
512 attrs: &[
513 AttrDef { id: "CogenerationPlant.ThermalGeneratingUnits", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ThermalGeneratingUnit", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "A thermal generating unit may be a member of a cogeneration plant." },
514 ],
515 },
516 ClassDef {
517 ns: "http://iec.ch/TC57/CIM100#",
518 local: "CombinedCyclePlant",
519 qualified: "CombinedCyclePlant",
520 super_class: Some(282),
521 concrete: true,
522 origins: &["EQ"],
523 comment: "A set of combustion turbines and steam turbines where the exhaust heat from the combustion turbines is recovered to make steam for the steam turbines, resulting in greater overall plant efficiency.",
524 attrs: &[
525 AttrDef { id: "CombinedCyclePlant.ThermalGeneratingUnits", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ThermalGeneratingUnit", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "A thermal generating unit may be a member of a combined cycle plant." },
526 ],
527 },
528 ClassDef {
529 ns: "http://iec.ch/TC57/CIM100#",
530 local: "Command",
531 qualified: "Command",
532 super_class: Some(45),
533 concrete: true,
534 origins: &["OP"],
535 comment: "A Command is a discrete control used for supervisory control.",
536 attrs: &[
537 AttrDef { id: "Command.DiscreteValue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DiscreteValue", is_list: false, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "The MeasurementValue that is controlled." },
538 AttrDef { id: "Command.ValueAliasSet", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ValueAliasSet", is_list: false, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "The ValueAliasSet used for translation of a Control value to a name." },
539 AttrDef { id: "Command.normalValue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["OP"], comment: "Normal value for Control.value e.g. used for percentage scaling." },
540 AttrDef { id: "Command.value", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["OP"], comment: "The value representing the actuator output." },
541 ],
542 },
543 ClassDef {
544 ns: "http://iec.ch/TC57/CIM100#",
545 local: "ConductingEquipment",
546 qualified: "ConductingEquipment",
547 super_class: Some(98),
548 concrete: false,
549 origins: &["EQ", "DY", "EQBD", "SC", "SSH", "SV"],
550 comment: "The parts of the AC power system that are designed to carry current or that are conductively connected through terminals.",
551 attrs: &[
552 AttrDef { id: "ConductingEquipment.BaseVoltage", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "BaseVoltage", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "Base voltage of this conducting equipment. Use only when there is no voltage level container used and only one base voltage applies. For example, not used for transformers." },
553 AttrDef { id: "ConductingEquipment.SvStatus", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SvStatus", is_list: false, used: false, xsd: "", value_ns: "", origins: &["SV"], comment: "The status state variable associated with this conducting equipment." },
554 AttrDef { id: "ConductingEquipment.Terminals", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Terminal", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ", "DY", "EQBD"], comment: "Conducting equipment have terminals that may be connected to other conducting equipment terminals via connectivity nodes or topological nodes." },
555 ],
556 },
557 ClassDef {
558 ns: "http://iec.ch/TC57/CIM100#",
559 local: "Conductor",
560 qualified: "Conductor",
561 super_class: Some(37),
562 concrete: false,
563 origins: &["EQ", "SC"],
564 comment: "Combination of conducting material with consistent electrical characteristics, building a single electrical system, used to carry current between points in the power system.",
565 attrs: &[
566 AttrDef { id: "Conductor.length", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Length", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Segment length for calculating line section capabilities." },
567 ],
568 },
569 ClassDef {
570 ns: "http://iec.ch/TC57/CIM100#",
571 local: "ConformLoad",
572 qualified: "ConformLoad",
573 super_class: Some(95),
574 concrete: true,
575 origins: &["EQ", "SSH"],
576 comment: "ConformLoad represent loads that follow a daily load change pattern where the pattern can be used to scale the load with a system load.",
577 attrs: &[
578 AttrDef { id: "ConformLoad.LoadGroup", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ConformLoadGroup", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "Group of this ConformLoad." },
579 ],
580 },
581 ClassDef {
582 ns: "http://iec.ch/TC57/CIM100#",
583 local: "ConformLoadGroup",
584 qualified: "ConformLoadGroup",
585 super_class: Some(227),
586 concrete: true,
587 origins: &["EQ"],
588 comment: "A group of loads conforming to an allocation pattern.",
589 attrs: &[
590 AttrDef { id: "ConformLoadGroup.ConformLoadSchedules", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ConformLoadSchedule", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The ConformLoadSchedules in the ConformLoadGroup." },
591 AttrDef { id: "ConformLoadGroup.EnergyConsumers", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ConformLoad", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "Conform loads assigned to this ConformLoadGroup." },
592 ],
593 },
594 ClassDef {
595 ns: "http://iec.ch/TC57/CIM100#",
596 local: "ConformLoadSchedule",
597 qualified: "ConformLoadSchedule",
598 super_class: Some(325),
599 concrete: true,
600 origins: &["EQ"],
601 comment: "A curve of load versus time (X-axis) showing the active power values (Y1-axis) and reactive power (Y2-axis) for each unit of the period covered. This curve represents a typical pattern of load over the time period for a given day type and season.",
602 attrs: &[
603 AttrDef { id: "ConformLoadSchedule.ConformLoadGroup", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ConformLoadGroup", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The ConformLoadGroup where the ConformLoadSchedule belongs." },
604 ],
605 },
606 ClassDef {
607 ns: "http://iec.ch/TC57/CIM100#",
608 local: "ConnectivityNode",
609 qualified: "ConnectivityNode",
610 super_class: Some(213),
611 concrete: true,
612 origins: &["EQ", "EQBD", "TP"],
613 comment: "Connectivity nodes are points where terminals of AC conducting equipment are connected together with zero impedance.",
614 attrs: &[
615 AttrDef { id: "ConnectivityNode.BoundaryPoint", ns: "http://iec.ch/TC57/CIM100-European#", kind: AttrKind::Association, range: "BoundaryPoint", is_list: false, used: false, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "The boundary point associated with the connectivity node." },
616 AttrDef { id: "ConnectivityNode.ConnectivityNodeContainer", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ConnectivityNodeContainer", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "Container of this connectivity node." },
617 AttrDef { id: "ConnectivityNode.Terminals", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Terminal", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "Terminals interconnected with zero impedance at a this connectivity node." },
618 AttrDef { id: "ConnectivityNode.TopologicalNode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TopologicalNode", is_list: false, used: true, xsd: "", value_ns: "", origins: &["TP"], comment: "The topological node to which this connectivity node is assigned. May depend on the current state of switches in the network." },
619 ],
620 },
621 ClassDef {
622 ns: "http://iec.ch/TC57/CIM100#",
623 local: "ConnectivityNodeContainer",
624 qualified: "ConnectivityNodeContainer",
625 super_class: Some(282),
626 concrete: false,
627 origins: &["EQ", "EQBD", "TP"],
628 comment: "A base class for all objects that may contain connectivity nodes or topological nodes.",
629 attrs: &[
630 AttrDef { id: "ConnectivityNodeContainer.ConnectivityNodes", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ConnectivityNode", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "Connectivity nodes which belong to this connectivity node container." },
631 AttrDef { id: "ConnectivityNodeContainer.TopologicalNode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TopologicalNode", is_list: true, used: false, xsd: "", value_ns: "", origins: &["TP"], comment: "The topological nodes which belong to this connectivity node container." },
632 ],
633 },
634 ClassDef {
635 ns: "http://iec.ch/TC57/CIM100#",
636 local: "Connector",
637 qualified: "Connector",
638 super_class: Some(37),
639 concrete: false,
640 origins: &["EQ", "EQBD", "SC"],
641 comment: "A conductor, or group of conductors, with negligible impedance, that serve to connect other conducting equipment within a single substation and are modelled with a single logical terminal.",
642 attrs: &[],
643 },
644 ClassDef {
645 ns: "http://iec.ch/TC57/CIM100#",
646 local: "Control",
647 qualified: "Control",
648 super_class: Some(212),
649 concrete: false,
650 origins: &["OP"],
651 comment: "Control is used for supervisory/device control. It represents control outputs that are used to change the state in a process, e.g. close or open breaker, a set point value or a raise lower command.",
652 attrs: &[
653 AttrDef { id: "Control.PowerSystemResource", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PowerSystemResource", is_list: false, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "Regulating device governed by this control output." },
654 AttrDef { id: "Control.controlType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["OP"], comment: "Specifies the type of Control. For example, this specifies if the Control represents BreakerOpen, BreakerClose, GeneratorVoltageSetPoint, GeneratorRaise, GeneratorLower, etc." },
655 AttrDef { id: "Control.operationInProgress", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["OP"], comment: "Indicates that a client is currently sending control commands that has not completed." },
656 AttrDef { id: "Control.timeStamp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "DateTime", is_list: false, used: true, xsd: "dateTime", value_ns: "", origins: &["OP"], comment: "The last time a control output was sent." },
657 AttrDef { id: "Control.unitMultiplier", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "UnitMultiplier", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["OP"], comment: "The unit multiplier of the controlled quantity." },
658 AttrDef { id: "Control.unitSymbol", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "UnitSymbol", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["OP"], comment: "The unit of measure of the controlled quantity." },
659 ],
660 },
661 ClassDef {
662 ns: "http://iec.ch/TC57/CIM100#",
663 local: "ControlArea",
664 qualified: "ControlArea",
665 super_class: Some(282),
666 concrete: true,
667 origins: &["EQ", "SSH"],
668 comment: "A control area is a grouping of generating units and/or loads and a cutset of tie lines (as terminals) which may be used for a variety of purposes including automatic generation control, power flow solution area interchange control specification, and input to load forecasting. All generation and load within the area defined by the terminals on the border are considered in the area interchange control. Note that any number of overlapping control area specifications can be superimposed on the physical model. The following general principles apply to ControlArea: 1. The control area orientation for net interchange is positive for an import, negative for an export. 2. The control area net interchange is determined by summing flows in Terminals. The Terminals are identified by creating a set of TieFlow objects associated with a ControlArea object. Each TieFlow object identifies one Terminal. 3. In a single network model, a tie between two control areas must be modelled in both control area specifications, such that the two representations of the tie flow sum to zero. 4. The normal orientation of Terminal flow is positive for flow into the conducting equipment that owns the Terminal. (i.e. flow from a bus into a device is positive.) However, the orientation of each flow in the control area specification must align with the control area convention, i.e. import is positive. If the orientation of the Terminal flow referenced by a TieFlow is positive into the control area, then this is confirmed by setting TieFlow.positiveFlowIn flag TRUE. If not, the orientation must be reversed by setting the TieFlow.positiveFlowIn flag FALSE.",
669 attrs: &[
670 AttrDef { id: "ControlArea.ControlAreaGeneratingUnit", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ControlAreaGeneratingUnit", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The generating unit specifications for the control area." },
671 AttrDef { id: "ControlArea.EnergyArea", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "EnergyArea", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The energy area that is forecast from this control area specification." },
672 AttrDef { id: "ControlArea.TieFlow", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TieFlow", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The tie flows associated with the control area." },
673 AttrDef { id: "ControlArea.netInterchange", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "The specified positive net interchange into the control area, i.e. positive sign means flow into the area." },
674 AttrDef { id: "ControlArea.pTolerance", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Active power net interchange tolerance. The attribute shall be a positive value or zero." },
675 AttrDef { id: "ControlArea.type", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "ControlAreaTypeKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "The primary type of control area definition used to determine if this is used for automatic generation control, for planning interchange control, or other purposes. A control area specified with primary type of automatic generation control could still be forecast and used as an interchange area in power flow analysis." },
676 ],
677 },
678 ClassDef {
679 ns: "http://iec.ch/TC57/CIM100#",
680 local: "ControlAreaGeneratingUnit",
681 qualified: "ControlAreaGeneratingUnit",
682 super_class: Some(213),
683 concrete: true,
684 origins: &["EQ"],
685 comment: "A control area generating unit. This class is needed so that alternate control area definitions may include the same generating unit. It should be noted that only one instance within a control area should reference a specific generating unit.",
686 attrs: &[
687 AttrDef { id: "ControlAreaGeneratingUnit.ControlArea", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ControlArea", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The parent control area for the generating unit specifications." },
688 AttrDef { id: "ControlAreaGeneratingUnit.GeneratingUnit", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "GeneratingUnit", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The generating unit specified for this control area. Note that a control area should include a GeneratingUnit only once." },
689 ],
690 },
691 ClassDef {
692 ns: "http://iec.ch/TC57/CIM100#",
693 local: "CoordinateSystem",
694 qualified: "CoordinateSystem",
695 super_class: Some(213),
696 concrete: true,
697 origins: &["GL"],
698 comment: "Coordinate reference system.",
699 attrs: &[
700 AttrDef { id: "CoordinateSystem.Locations", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Location", is_list: true, used: false, xsd: "", value_ns: "", origins: &["GL"], comment: "All locations described with position points in this coordinate system." },
701 AttrDef { id: "CoordinateSystem.crsUrn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "A Uniform Resource Name (URN) for the coordinate reference system (crs) used to define 'Location.PositionPoints'. An example would be the European Petroleum Survey Group (EPSG) code for a coordinate reference system, defined in URN under the Open Geospatial Consortium (OGC) namespace as: urn:ogc:def:crs:EPSG::XXXX, where XXXX is an EPSG code (a full list of codes can be found at the EPSG Registry web site http://www.epsg-registry.org/). To define the coordinate system as being WGS84 (latitude, longitude) using an EPSG OGC, this attribute would be urn:ogc:def:crs:EPSG::4236. A profile should limit this code to a set of allowed URNs agreed to by all sending and receiving parties." },
702 ],
703 },
704 ClassDef {
705 ns: "http://iec.ch/TC57/CIM100#",
706 local: "CrossCompoundTurbineGovernorDynamics",
707 qualified: "CrossCompoundTurbineGovernorDynamics",
708 super_class: Some(91),
709 concrete: false,
710 origins: &["DY"],
711 comment: "Turbine-governor cross-compound function block whose behaviour is described by reference to a standard model or by definition of a user-defined model.",
712 attrs: &[
713 AttrDef { id: "CrossCompoundTurbineGovernorDynamics.HighPressureSynchronousMachineDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SynchronousMachineDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "High-pressure synchronous machine with which this cross-compound turbine governor is associated." },
714 AttrDef { id: "CrossCompoundTurbineGovernorDynamics.LowPressureSynchronousMachineDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SynchronousMachineDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Low-pressure synchronous machine with which this cross-compound turbine governor is associated." },
715 ],
716 },
717 ClassDef {
718 ns: "http://iec.ch/TC57/CIM100#",
719 local: "CsConverter",
720 qualified: "CsConverter",
721 super_class: Some(0),
722 concrete: true,
723 origins: &["EQ", "DY", "SSH", "SV"],
724 comment: "DC side of the current source converter (CSC). The firing angle controls the dc voltage at the converter, both for rectifier and inverter. The difference between the dc voltages of the rectifier and inverter determines the dc current. The extinction angle is used to limit the dc voltage at the inverter, if needed, and is not used in active power control. The firing angle, transformer tap position and number of connected filters are the primary means to control a current source dc line. Higher level controls are built on top, e.g. dc voltage, dc current and active power. From a steady state perspective it is sufficient to specify the wanted active power transfer (ACDCConverter.targetPpcc) and the control functions will set the dc voltage, dc current, firing angle, transformer tap position and number of connected filters to meet this. Therefore attributes targetAlpha and targetGamma are not applicable in this case. The reactive power consumed by the converter is a function of the firing angle, transformer tap position and number of connected filter, which can be approximated with half of the active power. The losses is a function of the dc voltage and dc current. The attributes minAlpha and maxAlpha define the range of firing angles for rectifier operation between which no discrete tap changer action takes place. The range is typically 10-18 degrees. The attributes minGamma and maxGamma define the range of extinction angles for inverter operation between which no discrete tap changer action takes place. The range is typically 17-20 degrees.",
725 attrs: &[
726 AttrDef { id: "CsConverter.CSCDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "CSCDynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Current source converter dynamics model used to describe dynamic behaviour of this converter." },
727 AttrDef { id: "CsConverter.alpha", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SV"], comment: "Firing angle that determines the dc voltage at the converter dc terminal. Typical value between 10 degrees and 18 degrees for a rectifier. It is converter’s state variable, result from power flow. The attribute shall be a positive value." },
728 AttrDef { id: "CsConverter.gamma", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SV"], comment: "Extinction angle. It is used to limit the dc voltage at the inverter if needed. Typical value between 17 degrees and 20 degrees for an inverter. It is converter’s state variable, result from power flow. The attribute shall be a positive value." },
729 AttrDef { id: "CsConverter.maxAlpha", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Maximum firing angle. It is converter’s configuration data used in power flow. The attribute shall be a positive value." },
730 AttrDef { id: "CsConverter.maxGamma", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Maximum extinction angle. It is converter’s configuration data used in power flow. The attribute shall be a positive value." },
731 AttrDef { id: "CsConverter.maxIdc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "CurrentFlow", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The maximum direct current (Id) on the DC side at which the converter should operate. It is converter’s configuration data use in power flow. The attribute shall be a positive value." },
732 AttrDef { id: "CsConverter.minAlpha", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Minimum firing angle. It is converter’s configuration data used in power flow. The attribute shall be a positive value." },
733 AttrDef { id: "CsConverter.minGamma", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Minimum extinction angle. It is converter’s configuration data used in power flow. The attribute shall be a positive value." },
734 AttrDef { id: "CsConverter.minIdc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "CurrentFlow", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The minimum direct current (Id) on the DC side at which the converter should operate. It is converter’s configuration data used in power flow. The attribute shall be a positive value." },
735 AttrDef { id: "CsConverter.operatingMode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "CsOperatingModeKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["SSH"], comment: "Indicates whether the DC pole is operating as an inverter or as a rectifier. It is converter’s control variable used in power flow." },
736 AttrDef { id: "CsConverter.pPccControl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "CsPpccControlKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["SSH"], comment: "Kind of active power control." },
737 AttrDef { id: "CsConverter.ratedIdc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "CurrentFlow", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Rated converter DC current, also called IdN. The attribute shall be a positive value. It is converter’s configuration data used in power flow." },
738 AttrDef { id: "CsConverter.targetAlpha", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Target firing angle. It is converter’s control variable used in power flow. It is only applicable for rectifier if continuous tap changer control is used. Allowed values are within the range minAlpha<=targetAlpha<=maxAlpha. The attribute shall be a positive value." },
739 AttrDef { id: "CsConverter.targetGamma", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Target extinction angle. It is converter’s control variable used in power flow. It is only applicable for inverter if continuous tap changer control is used. Allowed values are within the range minGamma<=targetGamma<=maxGamma. The attribute shall be a positive value." },
740 AttrDef { id: "CsConverter.targetIdc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "CurrentFlow", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "DC current target value. It is converter’s control variable used in power flow. The attribute shall be a positive value." },
741 ],
742 },
743 ClassDef {
744 ns: "http://iec.ch/TC57/CIM100#",
745 local: "CurrentLimit",
746 qualified: "CurrentLimit",
747 super_class: Some(248),
748 concrete: true,
749 origins: &["EQ", "SSH"],
750 comment: "Operational limit on current.",
751 attrs: &[
752 AttrDef { id: "CurrentLimit.normalValue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "CurrentFlow", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The normal value for limit on current flow. The attribute shall be a positive value or zero." },
753 AttrDef { id: "CurrentLimit.value", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "CurrentFlow", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Limit on current flow. The attribute shall be a positive value or zero." },
754 ],
755 },
756 ClassDef {
757 ns: "http://iec.ch/TC57/CIM100#",
758 local: "CurrentTransformer",
759 qualified: "CurrentTransformer",
760 super_class: Some(326),
761 concrete: true,
762 origins: &["EQ"],
763 comment: "Instrument transformer used to measure electrical qualities of the circuit that is being protected and/or monitored. Typically used as current transducer for the purpose of metering or protection. A typical secondary current rating would be 5A.",
764 attrs: &[],
765 },
766 ClassDef {
767 ns: "http://iec.ch/TC57/CIM100#",
768 local: "Curve",
769 qualified: "Curve",
770 super_class: Some(213),
771 concrete: false,
772 origins: &["EQ"],
773 comment: "A multi-purpose curve or functional relationship between an independent variable (X-axis) and dependent (Y-axis) variables.",
774 attrs: &[
775 AttrDef { id: "Curve.CurveDatas", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "CurveData", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The point data values that define this curve." },
776 AttrDef { id: "Curve.curveStyle", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "CurveStyle", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "The style or shape of the curve." },
777 AttrDef { id: "Curve.xUnit", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "UnitSymbol", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "The X-axis units of measure." },
778 AttrDef { id: "Curve.y1Unit", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "UnitSymbol", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "The Y1-axis units of measure." },
779 AttrDef { id: "Curve.y2Unit", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "UnitSymbol", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "The Y2-axis units of measure." },
780 ],
781 },
782 ClassDef {
783 ns: "http://iec.ch/TC57/CIM100#",
784 local: "CurveData",
785 qualified: "CurveData",
786 super_class: None,
787 concrete: true,
788 origins: &["EQ"],
789 comment: "Multi-purpose data points for defining a curve. The use of this generic class is discouraged if a more specific class can be used to specify the X and Y axis values along with their specific data types.",
790 attrs: &[
791 AttrDef { id: "CurveData.Curve", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Curve", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The curve of this curve data point." },
792 AttrDef { id: "CurveData.xvalue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The data value of the X-axis variable, depending on the X-axis units." },
793 AttrDef { id: "CurveData.y1value", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The data value of the first Y-axis variable, depending on the Y-axis units." },
794 AttrDef { id: "CurveData.y2value", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The data value of the second Y-axis variable (if present), depending on the Y-axis units." },
795 ],
796 },
797 ClassDef {
798 ns: "http://iec.ch/TC57/CIM100#",
799 local: "Cut",
800 qualified: "Cut",
801 super_class: Some(353),
802 concrete: true,
803 origins: &["EQ"],
804 comment: "A cut separates a line segment into two parts. The cut appears as a switch inserted between these two parts and connects them together. As the cut is normally open there is no galvanic connection between the two line segment parts. But it is possible to close the cut to get galvanic connection. The cut terminals are oriented towards the line segment terminals with the same sequence number. Hence the cut terminal with sequence number equal to 1 is oriented to the line segment's terminal with sequence number equal to 1. The cut terminals also act as connection points for jumpers and other equipment, e.g. a mobile generator. To enable this, connectivity nodes are placed at the cut terminals. Once the connectivity nodes are in place any conducting equipment can be connected at them.",
805 attrs: &[
806 AttrDef { id: "Cut.ACLineSegment", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ACLineSegment", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The line segment to which the cut is applied." },
807 AttrDef { id: "Cut.lengthFromTerminal1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Length", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The length to the place where the cut is located starting from side one of the cut line segment, i.e. the line segment Terminal with sequenceNumber equal to 1." },
808 ],
809 },
810 ClassDef {
811 ns: "http://iec.ch/TC57/CIM100#",
812 local: "DCBaseTerminal",
813 qualified: "DCBaseTerminal",
814 super_class: Some(2),
815 concrete: false,
816 origins: &["EQ", "SSH", "TP"],
817 comment: "An electrical connection point at a piece of DC conducting equipment. DC terminals are connected at one physical DC node that may have multiple DC terminals connected. A DC node is similar to an AC connectivity node. The model requires that DC connections are distinct from AC connections.",
818 attrs: &[
819 AttrDef { id: "DCBaseTerminal.DCNode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DCNode", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The DC connectivity node to which this DC base terminal connects with zero impedance." },
820 AttrDef { id: "DCBaseTerminal.DCTopologicalNode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DCTopologicalNode", is_list: false, used: true, xsd: "", value_ns: "", origins: &["TP"], comment: "See association end Terminal.TopologicalNode." },
821 ],
822 },
823 ClassDef {
824 ns: "http://iec.ch/TC57/CIM100#",
825 local: "DCBreaker",
826 qualified: "DCBreaker",
827 super_class: Some(70),
828 concrete: true,
829 origins: &["EQ"],
830 comment: "A breaker within a DC system.",
831 attrs: &[],
832 },
833 ClassDef {
834 ns: "http://iec.ch/TC57/CIM100#",
835 local: "DCBusbar",
836 qualified: "DCBusbar",
837 super_class: Some(60),
838 concrete: true,
839 origins: &["EQ"],
840 comment: "A busbar within a DC system.",
841 attrs: &[],
842 },
843 ClassDef {
844 ns: "http://iec.ch/TC57/CIM100#",
845 local: "DCChopper",
846 qualified: "DCChopper",
847 super_class: Some(60),
848 concrete: true,
849 origins: &["EQ"],
850 comment: "Low resistance equipment used in the internal DC circuit to balance voltages. It has typically positive and negative pole terminals and a ground.",
851 attrs: &[],
852 },
853 ClassDef {
854 ns: "http://iec.ch/TC57/CIM100#",
855 local: "DCConductingEquipment",
856 qualified: "DCConductingEquipment",
857 super_class: Some(98),
858 concrete: false,
859 origins: &["EQ"],
860 comment: "The parts of the DC power system that are designed to carry current or that are conductively connected through DC terminals.",
861 attrs: &[
862 AttrDef { id: "DCConductingEquipment.DCTerminals", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DCTerminal", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "A DC conducting equipment has DC terminals." },
863 AttrDef { id: "DCConductingEquipment.ratedUdc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Rated DC device voltage. The attribute shall be a positive value. It is configuration data used in power flow." },
864 ],
865 },
866 ClassDef {
867 ns: "http://iec.ch/TC57/CIM100#",
868 local: "DCConverterUnit",
869 qualified: "DCConverterUnit",
870 super_class: Some(63),
871 concrete: true,
872 origins: &["EQ"],
873 comment: "Indivisible operative unit comprising all equipment between the point of common coupling on the AC side and the point of common coupling - DC side, essentially one or more converters, together with one or more converter transformers, converter control equipment, essential protective and switching devices and auxiliaries, if any, used for conversion.",
874 attrs: &[
875 AttrDef { id: "DCConverterUnit.Substation", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Substation", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The containing substation of the DC converter unit." },
876 AttrDef { id: "DCConverterUnit.operationMode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "DCConverterOperatingModeKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "The operating mode of an HVDC bipole (bipolar, monopolar metallic return, etc)." },
877 ],
878 },
879 ClassDef {
880 ns: "http://iec.ch/TC57/CIM100#",
881 local: "DCDisconnector",
882 qualified: "DCDisconnector",
883 super_class: Some(70),
884 concrete: true,
885 origins: &["EQ"],
886 comment: "A disconnector within a DC system.",
887 attrs: &[],
888 },
889 ClassDef {
890 ns: "http://iec.ch/TC57/CIM100#",
891 local: "DCEquipmentContainer",
892 qualified: "DCEquipmentContainer",
893 super_class: Some(99),
894 concrete: false,
895 origins: &["EQ", "TP"],
896 comment: "A modelling construct to provide a root class for containment of DC as well as AC equipment. The class differ from the EquipmentContaner for AC in that it may also contain DCNode-s. Hence it can contain both AC and DC equipment.",
897 attrs: &[
898 AttrDef { id: "DCEquipmentContainer.DCNodes", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DCNode", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The DC nodes contained in the DC equipment container." },
899 AttrDef { id: "DCEquipmentContainer.DCTopologicalNode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DCTopologicalNode", is_list: true, used: false, xsd: "", value_ns: "", origins: &["TP"], comment: "The topological nodes which belong to this connectivity node container." },
900 ],
901 },
902 ClassDef {
903 ns: "http://iec.ch/TC57/CIM100#",
904 local: "DCGround",
905 qualified: "DCGround",
906 super_class: Some(60),
907 concrete: true,
908 origins: &["EQ"],
909 comment: "A ground within a DC system.",
910 attrs: &[
911 AttrDef { id: "DCGround.inductance", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Inductance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Inductance to ground." },
912 AttrDef { id: "DCGround.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Resistance to ground." },
913 ],
914 },
915 ClassDef {
916 ns: "http://iec.ch/TC57/CIM100#",
917 local: "DCLine",
918 qualified: "DCLine",
919 super_class: Some(63),
920 concrete: true,
921 origins: &["EQ"],
922 comment: "Overhead lines and/or cables connecting two or more HVDC substations.",
923 attrs: &[
924 AttrDef { id: "DCLine.Region", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SubGeographicalRegion", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The SubGeographicalRegion containing the DC line." },
925 ],
926 },
927 ClassDef {
928 ns: "http://iec.ch/TC57/CIM100#",
929 local: "DCLineSegment",
930 qualified: "DCLineSegment",
931 super_class: Some(60),
932 concrete: true,
933 origins: &["EQ"],
934 comment: "A wire or combination of wires not insulated from one another, with consistent electrical characteristics, used to carry direct current between points in the DC region of the power system.",
935 attrs: &[
936 AttrDef { id: "DCLineSegment.capacitance", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Capacitance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Capacitance of the DC line segment. Significant for cables only." },
937 AttrDef { id: "DCLineSegment.inductance", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Inductance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Inductance of the DC line segment. Negligible compared with DCSeriesDevice used for smoothing." },
938 AttrDef { id: "DCLineSegment.length", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Length", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Segment length for calculating line section capabilities." },
939 AttrDef { id: "DCLineSegment.resistance", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Resistance of the DC line segment." },
940 ],
941 },
942 ClassDef {
943 ns: "http://iec.ch/TC57/CIM100#",
944 local: "DCNode",
945 qualified: "DCNode",
946 super_class: Some(213),
947 concrete: true,
948 origins: &["EQ", "TP"],
949 comment: "DC nodes are points where terminals of DC conducting equipment are connected together with zero impedance.",
950 attrs: &[
951 AttrDef { id: "DCNode.DCEquipmentContainer", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DCEquipmentContainer", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The DC container for the DC nodes." },
952 AttrDef { id: "DCNode.DCTerminals", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DCBaseTerminal", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "DC base terminals interconnected with zero impedance at a this DC connectivity node." },
953 AttrDef { id: "DCNode.DCTopologicalNode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DCTopologicalNode", is_list: false, used: true, xsd: "", value_ns: "", origins: &["TP"], comment: "The DC topological node to which this DC connectivity node is assigned. May depend on the current state of switches in the network." },
954 ],
955 },
956 ClassDef {
957 ns: "http://iec.ch/TC57/CIM100#",
958 local: "DCSeriesDevice",
959 qualified: "DCSeriesDevice",
960 super_class: Some(60),
961 concrete: true,
962 origins: &["EQ"],
963 comment: "A series device within the DC system, typically a reactor used for filtering or smoothing. Needed for transient and short circuit studies.",
964 attrs: &[
965 AttrDef { id: "DCSeriesDevice.inductance", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Inductance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Inductance of the device." },
966 AttrDef { id: "DCSeriesDevice.resistance", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Resistance of the DC device." },
967 ],
968 },
969 ClassDef {
970 ns: "http://iec.ch/TC57/CIM100#",
971 local: "DCShunt",
972 qualified: "DCShunt",
973 super_class: Some(60),
974 concrete: true,
975 origins: &["EQ"],
976 comment: "A shunt device within the DC system, typically used for filtering. Needed for transient and short circuit studies.",
977 attrs: &[
978 AttrDef { id: "DCShunt.capacitance", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Capacitance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Capacitance of the DC shunt." },
979 AttrDef { id: "DCShunt.resistance", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Resistance of the DC device." },
980 ],
981 },
982 ClassDef {
983 ns: "http://iec.ch/TC57/CIM100#",
984 local: "DCSwitch",
985 qualified: "DCSwitch",
986 super_class: Some(60),
987 concrete: true,
988 origins: &["EQ"],
989 comment: "A switch within the DC system.",
990 attrs: &[],
991 },
992 ClassDef {
993 ns: "http://iec.ch/TC57/CIM100#",
994 local: "DCTerminal",
995 qualified: "DCTerminal",
996 super_class: Some(56),
997 concrete: true,
998 origins: &["EQ", "SSH", "TP"],
999 comment: "An electrical connection point to generic DC conducting equipment.",
1000 attrs: &[
1001 AttrDef { id: "DCTerminal.DCConductingEquipment", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DCConductingEquipment", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "An DC terminal belong to a DC conducting equipment." },
1002 ],
1003 },
1004 ClassDef {
1005 ns: "http://iec.ch/TC57/CIM100#",
1006 local: "DCTopologicalIsland",
1007 qualified: "DCTopologicalIsland",
1008 super_class: Some(213),
1009 concrete: true,
1010 origins: &["SV"],
1011 comment: "An electrically connected subset of the network. DC topological islands can change as the current network state changes, e.g. due to: - disconnect switches or breakers changing state in a SCADA/EMS. - manual creation, change or deletion of topological nodes in a planning tool. Only energised TopologicalNode-s shall be part of the topological island.",
1012 attrs: &[
1013 AttrDef { id: "DCTopologicalIsland.DCTopologicalNodes", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DCTopologicalNode", is_list: true, used: true, xsd: "", value_ns: "", origins: &["SV"], comment: "The DC topological nodes in a DC topological island." },
1014 ],
1015 },
1016 ClassDef {
1017 ns: "http://iec.ch/TC57/CIM100#",
1018 local: "DCTopologicalNode",
1019 qualified: "DCTopologicalNode",
1020 super_class: Some(213),
1021 concrete: true,
1022 origins: &["TP", "SV"],
1023 comment: "DC bus.",
1024 attrs: &[
1025 AttrDef { id: "DCTopologicalNode.DCEquipmentContainer", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DCEquipmentContainer", is_list: false, used: true, xsd: "", value_ns: "", origins: &["TP"], comment: "The connectivity node container to which the topological node belongs." },
1026 AttrDef { id: "DCTopologicalNode.DCNodes", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DCNode", is_list: true, used: false, xsd: "", value_ns: "", origins: &["TP"], comment: "The DC connectivity nodes combined together to form this DC topological node. May depend on the current state of switches in the network." },
1027 AttrDef { id: "DCTopologicalNode.DCTerminals", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DCBaseTerminal", is_list: true, used: false, xsd: "", value_ns: "", origins: &["TP"], comment: "See association end TopologicalNode.Terminal." },
1028 AttrDef { id: "DCTopologicalNode.DCTopologicalIsland", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DCTopologicalIsland", is_list: false, used: false, xsd: "", value_ns: "", origins: &["SV"], comment: "A DC topological node belongs to a DC topological island." },
1029 ],
1030 },
1031 ClassDef {
1032 ns: "http://iec.ch/TC57/CIM100#",
1033 local: "DayType",
1034 qualified: "DayType",
1035 super_class: Some(213),
1036 concrete: true,
1037 origins: &["EQ"],
1038 comment: "Group of similar days. For example it could be used to represent weekdays, weekend, or holidays.",
1039 attrs: &[
1040 AttrDef { id: "DayType.SeasonDayTypeSchedules", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SeasonDayTypeSchedule", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "Schedules that use this DayType." },
1041 ],
1042 },
1043 ClassDef {
1044 ns: "http://iec.ch/TC57/CIM100#",
1045 local: "Diagram",
1046 qualified: "Diagram",
1047 super_class: Some(213),
1048 concrete: true,
1049 origins: &["DL"],
1050 comment: "The diagram being exchanged. The coordinate system is a standard Cartesian coordinate system and the orientation attribute defines the orientation. The initial view related attributes can be used to specify an initial view with the x,y coordinates of the diagonal points.",
1051 attrs: &[
1052 AttrDef { id: "Diagram.DiagramElements", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DiagramObject", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DL"], comment: "A diagram is made up of multiple diagram objects." },
1053 AttrDef { id: "Diagram.DiagramStyle", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DiagramStyle", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DL"], comment: "A Diagram may have a DiagramStyle." },
1054 AttrDef { id: "Diagram.orientation", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "OrientationKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DL"], comment: "Coordinate system orientation of the diagram. A positive orientation gives standard “right-hand” orientation, with negative orientation indicating a “left-hand” orientation. For 2D diagrams, a positive orientation will result in X values increasing from left to right and Y values increasing from bottom to top. A negative orientation gives the “left-hand” orientation (favoured by computer graphics displays) with X values increasing from left to right and Y values increasing from top to bottom." },
1055 AttrDef { id: "Diagram.x1InitialView", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DL"], comment: "X coordinate of the first corner of the initial view." },
1056 AttrDef { id: "Diagram.x2InitialView", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DL"], comment: "X coordinate of the second corner of the initial view." },
1057 AttrDef { id: "Diagram.y1InitialView", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DL"], comment: "Y coordinate of the first corner of the initial view." },
1058 AttrDef { id: "Diagram.y2InitialView", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DL"], comment: "Y coordinate of the second corner of the initial view." },
1059 ],
1060 },
1061 ClassDef {
1062 ns: "http://iec.ch/TC57/CIM100#",
1063 local: "DiagramObject",
1064 qualified: "DiagramObject",
1065 super_class: Some(213),
1066 concrete: true,
1067 origins: &["DL"],
1068 comment: "An object that defines one or more points in a given space. This object can be associated with anything that specializes IdentifiedObject. For single line diagrams such objects typically include such items as analog values, breakers, disconnectors, power transformers, and transmission lines.",
1069 attrs: &[
1070 AttrDef { id: "DiagramObject.Diagram", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Diagram", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DL"], comment: "A diagram object is part of a diagram." },
1071 AttrDef { id: "DiagramObject.DiagramObjectPoints", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DiagramObjectPoint", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DL"], comment: "A diagram object can have 0 or more points to reflect its layout position, routing (for polylines) or boundary (for polygons)." },
1072 AttrDef { id: "DiagramObject.DiagramObjectStyle", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DiagramObjectStyle", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DL"], comment: "A diagram object has a style associated that provides a reference for the style used in the originating system." },
1073 AttrDef { id: "DiagramObject.IdentifiedObject", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "IdentifiedObject", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DL"], comment: "The domain object to which this diagram object is associated." },
1074 AttrDef { id: "DiagramObject.VisibilityLayers", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "VisibilityLayer", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DL"], comment: "A diagram object can be part of multiple visibility layers." },
1075 AttrDef { id: "DiagramObject.drawingOrder", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["DL"], comment: "The drawing order of this element. The higher the number, the later the element is drawn in sequence. This is used to ensure that elements that overlap are rendered in the correct order." },
1076 AttrDef { id: "DiagramObject.isPolygon", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DL"], comment: "Defines whether or not the diagram objects points define the boundaries of a polygon or the routing of a polyline. If this value is true then a receiving application should consider the first and last points to be connected." },
1077 AttrDef { id: "DiagramObject.offsetX", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DL"], comment: "The offset in the X direction. This is used for defining the offset from centre for rendering an icon (the default is that a single point specifies the centre of the icon). The offset is in per-unit with 0 indicating there is no offset from the horizontal centre of the icon. -0.5 indicates it is offset by 50% to the left and 0.5 indicates an offset of 50% to the right." },
1078 AttrDef { id: "DiagramObject.offsetY", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DL"], comment: "The offset in the Y direction. This is used for defining the offset from centre for rendering an icon (the default is that a single point specifies the centre of the icon). The offset is in per-unit with 0 indicating there is no offset from the vertical centre of the icon. The offset direction is dependent on the orientation of the diagram, with -0.5 and 0.5 indicating an offset of +/- 50% on the vertical axis." },
1079 AttrDef { id: "DiagramObject.rotation", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DL"], comment: "Sets the angle of rotation of the diagram object. Zero degrees is pointing to the top of the diagram. Rotation is clockwise. DiagramObject.rotation=0 has the following meaning: The connection point of an element which has one terminal is pointing to the top side of the diagram. The connection point 'From side' of an element which has more than one terminal is pointing to the top side of the diagram. DiagramObject.rotation=90 has the following meaning: The connection point of an element which has one terminal is pointing to the right hand side of the diagram. The connection point 'From side' of an element which has more than one terminal is pointing to the right hand side of the diagram." },
1080 ],
1081 },
1082 ClassDef {
1083 ns: "http://iec.ch/TC57/CIM100#",
1084 local: "DiagramObjectGluePoint",
1085 qualified: "DiagramObjectGluePoint",
1086 super_class: None,
1087 concrete: true,
1088 origins: &["DL"],
1089 comment: "This is used for grouping diagram object points from different diagram objects that are considered to be glued together in a diagram even if they are not at the exact same coordinates.",
1090 attrs: &[
1091 AttrDef { id: "DiagramObjectGluePoint.DiagramObjectPoints", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DiagramObjectPoint", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DL"], comment: "A diagram object glue point is associated with 2 or more object points that are considered to be 'glued' together." },
1092 ],
1093 },
1094 ClassDef {
1095 ns: "http://iec.ch/TC57/CIM100#",
1096 local: "DiagramObjectPoint",
1097 qualified: "DiagramObjectPoint",
1098 super_class: None,
1099 concrete: true,
1100 origins: &["DL"],
1101 comment: "A point in a given space defined by 3 coordinates and associated to a diagram object. The coordinates may be positive or negative as the origin does not have to be in the corner of a diagram.",
1102 attrs: &[
1103 AttrDef { id: "DiagramObjectPoint.DiagramObject", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DiagramObject", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DL"], comment: "The diagram object with which the points are associated." },
1104 AttrDef { id: "DiagramObjectPoint.DiagramObjectGluePoint", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DiagramObjectGluePoint", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DL"], comment: "The 'glue' point to which this point is associated." },
1105 AttrDef { id: "DiagramObjectPoint.sequenceNumber", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["DL"], comment: "The sequence position of the point, used for defining the order of points for diagram objects acting as a polyline or polygon with more than one point. The attribute shall be a positive value." },
1106 AttrDef { id: "DiagramObjectPoint.xPosition", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DL"], comment: "The X coordinate of this point." },
1107 AttrDef { id: "DiagramObjectPoint.yPosition", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DL"], comment: "The Y coordinate of this point." },
1108 AttrDef { id: "DiagramObjectPoint.zPosition", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DL"], comment: "The Z coordinate of this point." },
1109 ],
1110 },
1111 ClassDef {
1112 ns: "http://iec.ch/TC57/CIM100#",
1113 local: "DiagramObjectStyle",
1114 qualified: "DiagramObjectStyle",
1115 super_class: Some(213),
1116 concrete: true,
1117 origins: &["DL"],
1118 comment: "A reference to a style used by the originating system for a diagram object. A diagram object style describes information such as line thickness, shape such as circle or rectangle etc, and colour.",
1119 attrs: &[
1120 AttrDef { id: "DiagramObjectStyle.StyledObjects", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DiagramObject", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DL"], comment: "A style can be assigned to multiple diagram objects." },
1121 ],
1122 },
1123 ClassDef {
1124 ns: "http://iec.ch/TC57/CIM100#",
1125 local: "DiagramStyle",
1126 qualified: "DiagramStyle",
1127 super_class: Some(213),
1128 concrete: true,
1129 origins: &["DL"],
1130 comment: "The diagram style refers to a style used by the originating system for a diagram. A diagram style describes information such as schematic, geographic, etc.",
1131 attrs: &[
1132 AttrDef { id: "DiagramStyle.Diagram", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Diagram", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DL"], comment: "A DiagramStyle can be used by many Diagrams." },
1133 ],
1134 },
1135 ClassDef {
1136 ns: "http://iec.ch/TC57/61970-552/DifferenceModel/1#",
1137 local: "DifferenceModel",
1138 qualified: "DifferenceModel",
1139 super_class: Some(240),
1140 concrete: true,
1141 origins: &["FH"],
1142 comment: "It represents the difference model header. The content is described by the Model class, the association role forwardDifferences and association role reverseDifferences. Both association roles may have one set of Statements.",
1143 attrs: &[
1144 AttrDef { id: "DifferenceModel.forwardDifferences", ns: "http://iec.ch/TC57/61970-552/DifferenceModel/1#", kind: AttrKind::Association, range: "Statements", is_list: true, used: true, xsd: "", value_ns: "", origins: &["FH"], comment: "A property of the difference model whose value is a collection of statements (i.e., resources of type rdf:Statement) representing the forward difference statements." },
1145 AttrDef { id: "DifferenceModel.preconditions", ns: "http://iec.ch/TC57/61970-552/DifferenceModel/1#", kind: AttrKind::Association, range: "Statements", is_list: true, used: true, xsd: "", value_ns: "", origins: &["FH"], comment: "A property of the difference model whose value is the collection of precondition statements." },
1146 AttrDef { id: "DifferenceModel.reverseDifferences", ns: "http://iec.ch/TC57/61970-552/DifferenceModel/1#", kind: AttrKind::Association, range: "Statements", is_list: true, used: true, xsd: "", value_ns: "", origins: &["FH"], comment: "A property of the difference model whose value is the collection of reverse difference statements." },
1147 ],
1148 },
1149 ClassDef {
1150 ns: "http://iec.ch/TC57/CIM100#",
1151 local: "DiscExcContIEEEDEC1A",
1152 qualified: "DiscExcContIEEEDEC1A",
1153 super_class: Some(87),
1154 concrete: true,
1155 origins: &["DY"],
1156 comment: "IEEE type DEC1A discontinuous excitation control model that boosts generator excitation to a level higher than that demanded by the voltage regulator and stabilizer immediately following a system fault. Reference: IEEE 421.5-2005, 12.2.",
1157 attrs: &[
1158 AttrDef { id: "DiscExcContIEEEDEC1A.esc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Speed change reference (ESC). Typical value = 0,0015." },
1159 AttrDef { id: "DiscExcContIEEEDEC1A.kan", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Discontinuous controller gain (KAN). Typical value = 400." },
1160 AttrDef { id: "DiscExcContIEEEDEC1A.ketl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Terminal voltage limiter gain (KETL). Typical value = 47." },
1161 AttrDef { id: "DiscExcContIEEEDEC1A.tan", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Discontinuous controller time constant (TAN) (>= 0). Typical value = 0,08." },
1162 AttrDef { id: "DiscExcContIEEEDEC1A.td", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (TD) (>= 0). Typical value = 0,03." },
1163 AttrDef { id: "DiscExcContIEEEDEC1A.tl1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (TL1) (>= 0). Typical value = 0,025." },
1164 AttrDef { id: "DiscExcContIEEEDEC1A.tl2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (TL2) (>= 0). Typical value = 1,25." },
1165 AttrDef { id: "DiscExcContIEEEDEC1A.tw5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "DEC washout time constant (TW5) (>= 0). Typical value = 5." },
1166 AttrDef { id: "DiscExcContIEEEDEC1A.val", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Regulator voltage reference (VAL). Typical value = 5,5." },
1167 AttrDef { id: "DiscExcContIEEEDEC1A.vanmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter for Van (VANMAX)." },
1168 AttrDef { id: "DiscExcContIEEEDEC1A.vomax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter (VOMAX) (> DiscExcContIEEEDEC1A.vomin). Typical value = 0,3." },
1169 AttrDef { id: "DiscExcContIEEEDEC1A.vomin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter (VOMIN) (< DiscExcContIEEEDEC1A.vomax). Typical value = 0,1." },
1170 AttrDef { id: "DiscExcContIEEEDEC1A.vsmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter (VSMAX)(> DiscExcContIEEEDEC1A.vsmin). Typical value = 0,2." },
1171 AttrDef { id: "DiscExcContIEEEDEC1A.vsmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter (VSMIN) (< DiscExcContIEEEDEC1A.vsmax). Typical value = -0,066." },
1172 AttrDef { id: "DiscExcContIEEEDEC1A.vtc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Terminal voltage level reference (VTC). Typical value = 0,95." },
1173 AttrDef { id: "DiscExcContIEEEDEC1A.vtlmt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage reference (VTLMT). Typical value = 1,1." },
1174 AttrDef { id: "DiscExcContIEEEDEC1A.vtm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage limits (VTM). Typical value = 1,13." },
1175 AttrDef { id: "DiscExcContIEEEDEC1A.vtn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage limits (VTN). Typical value = 1,12." },
1176 ],
1177 },
1178 ClassDef {
1179 ns: "http://iec.ch/TC57/CIM100#",
1180 local: "DiscExcContIEEEDEC2A",
1181 qualified: "DiscExcContIEEEDEC2A",
1182 super_class: Some(87),
1183 concrete: true,
1184 origins: &["DY"],
1185 comment: "IEEE type DEC2A model for discontinuous excitation control. This system provides transient excitation boosting via an open-loop control as initiated by a trigger signal generated remotely. Reference: IEEE 421.5-2005 12.3.",
1186 attrs: &[
1187 AttrDef { id: "DiscExcContIEEEDEC2A.td1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Discontinuous controller time constant (TD1) (>= 0)." },
1188 AttrDef { id: "DiscExcContIEEEDEC2A.td2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Discontinuous controller washout time constant (TD2) (>= 0)." },
1189 AttrDef { id: "DiscExcContIEEEDEC2A.vdmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter (VDMAX) (> DiscExcContIEEEDEC2A.vdmin)." },
1190 AttrDef { id: "DiscExcContIEEEDEC2A.vdmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter (VDMIN) (< DiscExcContIEEEDEC2A.vdmax)." },
1191 AttrDef { id: "DiscExcContIEEEDEC2A.vk", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Discontinuous controller input reference (VK)." },
1192 ],
1193 },
1194 ClassDef {
1195 ns: "http://iec.ch/TC57/CIM100#",
1196 local: "DiscExcContIEEEDEC3A",
1197 qualified: "DiscExcContIEEEDEC3A",
1198 super_class: Some(87),
1199 concrete: true,
1200 origins: &["DY"],
1201 comment: "IEEE type DEC3A model. In some systems, the stabilizer output is disconnected from the regulator immediately following a severe fault to prevent the stabilizer from competing with action of voltage regulator during the first swing. Reference: IEEE 421.5-2005 12.4.",
1202 attrs: &[
1203 AttrDef { id: "DiscExcContIEEEDEC3A.tdr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reset time delay (TDR) (>= 0)." },
1204 AttrDef { id: "DiscExcContIEEEDEC3A.vtmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Terminal undervoltage comparison level (VTMIN)." },
1205 ],
1206 },
1207 ClassDef {
1208 ns: "http://iec.ch/TC57/CIM100#",
1209 local: "DisconnectingCircuitBreaker",
1210 qualified: "DisconnectingCircuitBreaker",
1211 super_class: Some(27),
1212 concrete: true,
1213 origins: &["EQ", "SSH"],
1214 comment: "A circuit breaking device including disconnecting function, eliminating the need for separate disconnectors.",
1215 attrs: &[],
1216 },
1217 ClassDef {
1218 ns: "http://iec.ch/TC57/CIM100#",
1219 local: "Disconnector",
1220 qualified: "Disconnector",
1221 super_class: Some(353),
1222 concrete: true,
1223 origins: &["EQ", "SSH"],
1224 comment: "A manually operated or motor operated mechanical switching device used for changing the connections in a circuit, or for isolating a circuit or equipment from a source of power. It is required to open or close circuits when negligible current is broken or made.",
1225 attrs: &[],
1226 },
1227 ClassDef {
1228 ns: "http://iec.ch/TC57/CIM100#",
1229 local: "DiscontinuousExcitationControlDynamics",
1230 qualified: "DiscontinuousExcitationControlDynamics",
1231 super_class: Some(91),
1232 concrete: false,
1233 origins: &["DY"],
1234 comment: "Discontinuous excitation control function block whose behaviour is described by reference to a standard model or by definition of a user-defined model.",
1235 attrs: &[
1236 AttrDef { id: "DiscontinuousExcitationControlDynamics.ExcitationSystemDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ExcitationSystemDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Excitation system model with which this discontinuous excitation control model is associated." },
1237 AttrDef { id: "DiscontinuousExcitationControlDynamics.RemoteInputSignal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RemoteInputSignal", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Remote input signal used by this discontinuous excitation control system model." },
1238 ],
1239 },
1240 ClassDef {
1241 ns: "http://iec.ch/TC57/CIM100#",
1242 local: "DiscontinuousExcitationControlUserDefined",
1243 qualified: "DiscontinuousExcitationControlUserDefined",
1244 super_class: Some(87),
1245 concrete: true,
1246 origins: &["DY"],
1247 comment: "Discontinuous excitation control function block whose dynamic behaviour is described by a user-defined model.",
1248 attrs: &[
1249 AttrDef { id: "DiscontinuousExcitationControlUserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
1250 AttrDef { id: "DiscontinuousExcitationControlUserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
1251 ],
1252 },
1253 ClassDef {
1254 ns: "http://iec.ch/TC57/CIM100#",
1255 local: "Discrete",
1256 qualified: "Discrete",
1257 super_class: Some(233),
1258 concrete: true,
1259 origins: &["OP"],
1260 comment: "Discrete represents a discrete Measurement, i.e. a Measurement representing discrete values, e.g. a Breaker position.",
1261 attrs: &[
1262 AttrDef { id: "Discrete.DiscreteValues", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DiscreteValue", is_list: true, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "The values connected to this measurement." },
1263 AttrDef { id: "Discrete.ValueAliasSet", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ValueAliasSet", is_list: false, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "The ValueAliasSet used for translation of a MeasurementValue.value to a name." },
1264 ],
1265 },
1266 ClassDef {
1267 ns: "http://iec.ch/TC57/CIM100#",
1268 local: "DiscreteValue",
1269 qualified: "DiscreteValue",
1270 super_class: Some(234),
1271 concrete: true,
1272 origins: &["OP"],
1273 comment: "DiscreteValue represents a discrete MeasurementValue.",
1274 attrs: &[
1275 AttrDef { id: "DiscreteValue.Command", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Command", is_list: false, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "The Control variable associated with the MeasurementValue." },
1276 AttrDef { id: "DiscreteValue.Discrete", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Discrete", is_list: false, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "Measurement to which this value is connected." },
1277 ],
1278 },
1279 ClassDef {
1280 ns: "http://iec.ch/TC57/CIM100#",
1281 local: "DynamicsFunctionBlock",
1282 qualified: "DynamicsFunctionBlock",
1283 super_class: Some(213),
1284 concrete: false,
1285 origins: &["DY"],
1286 comment: "Abstract parent class for all Dynamics function blocks.",
1287 attrs: &[
1288 AttrDef { id: "DynamicsFunctionBlock.enabled", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Function block used indicator. true = use of function block is enabled false = use of function block is disabled." },
1289 ],
1290 },
1291 ClassDef {
1292 ns: "http://iec.ch/TC57/CIM100#",
1293 local: "EarthFaultCompensator",
1294 qualified: "EarthFaultCompensator",
1295 super_class: Some(37),
1296 concrete: false,
1297 origins: &["EQ", "SC"],
1298 comment: "A conducting equipment used to represent a connection to ground which is typically used to compensate earth faults. An earth fault compensator device modelled with a single terminal implies a second terminal solidly connected to ground. If two terminals are modelled, the ground is not assumed and normal connection rules apply.",
1299 attrs: &[
1300 AttrDef { id: "EarthFaultCompensator.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Nominal resistance of device." },
1301 ],
1302 },
1303 ClassDef {
1304 ns: "http://iec.ch/TC57/CIM100#",
1305 local: "EnergyArea",
1306 qualified: "EnergyArea",
1307 super_class: Some(213),
1308 concrete: false,
1309 origins: &["EQ"],
1310 comment: "Describes an area having energy production or consumption. Specializations are intended to support the load allocation function as typically required in energy management systems or planning studies to allocate hypothesized load levels to individual load points for power flow analysis. Often the energy area can be linked to both measured and forecast load levels.",
1311 attrs: &[
1312 AttrDef { id: "EnergyArea.ControlArea", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ControlArea", is_list: false, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The control area specification that is used for the load forecast." },
1313 ],
1314 },
1315 ClassDef {
1316 ns: "http://iec.ch/TC57/CIM100#",
1317 local: "EnergyConnection",
1318 qualified: "EnergyConnection",
1319 super_class: Some(37),
1320 concrete: false,
1321 origins: &["EQ", "DY", "SC", "SSH"],
1322 comment: "A connection of energy generation or consumption on the power system model.",
1323 attrs: &[],
1324 },
1325 ClassDef {
1326 ns: "http://iec.ch/TC57/CIM100#",
1327 local: "EnergyConsumer",
1328 qualified: "EnergyConsumer",
1329 super_class: Some(94),
1330 concrete: true,
1331 origins: &["EQ", "DY", "SSH"],
1332 comment: "Generic user of energy - a point of consumption on the power system model. EnergyConsumer.pfixed, .qfixed, .pfixedPct and .qfixedPct have meaning only if there is no LoadResponseCharacteristic associated with EnergyConsumer or if LoadResponseCharacteristic.exponentModel is set to False.",
1333 attrs: &[
1334 AttrDef { id: "EnergyConsumer.LoadDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "LoadDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Load dynamics model used to describe dynamic behaviour of this energy consumer." },
1335 AttrDef { id: "EnergyConsumer.LoadResponse", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "LoadResponseCharacteristic", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The load response characteristic of this load. If missing, this load is assumed to be constant power." },
1336 AttrDef { id: "EnergyConsumer.p", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Active power of the load. Load sign convention is used, i.e. positive sign means flow out from a node. For voltage dependent loads the value is at rated voltage. Starting value for a steady state solution." },
1337 AttrDef { id: "EnergyConsumer.pfixed", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Active power of the load that is a fixed quantity and does not vary as load group value varies. Load sign convention is used, i.e. positive sign means flow out from a node." },
1338 AttrDef { id: "EnergyConsumer.pfixedPct", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PerCent", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Fixed active power as a percentage of load group fixed active power. Used to represent the time-varying components. Load sign convention is used, i.e. positive sign means flow out from a node." },
1339 AttrDef { id: "EnergyConsumer.q", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Reactive power of the load. Load sign convention is used, i.e. positive sign means flow out from a node. For voltage dependent loads the value is at rated voltage. Starting value for a steady state solution." },
1340 AttrDef { id: "EnergyConsumer.qfixed", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Reactive power of the load that is a fixed quantity and does not vary as load group value varies. Load sign convention is used, i.e. positive sign means flow out from a node." },
1341 AttrDef { id: "EnergyConsumer.qfixedPct", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PerCent", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Fixed reactive power as a percentage of load group fixed reactive power. Used to represent the time-varying components. Load sign convention is used, i.e. positive sign means flow out from a node." },
1342 ],
1343 },
1344 ClassDef {
1345 ns: "http://iec.ch/TC57/CIM100#",
1346 local: "EnergySchedulingType",
1347 qualified: "EnergySchedulingType",
1348 super_class: Some(213),
1349 concrete: true,
1350 origins: &["EQ", "EQBD"],
1351 comment: "Used to define the type of generation for scheduling purposes.",
1352 attrs: &[
1353 AttrDef { id: "EnergySchedulingType.EnergySource", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "EnergySource", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "Energy Source of a particular Energy Scheduling Type." },
1354 ],
1355 },
1356 ClassDef {
1357 ns: "http://iec.ch/TC57/CIM100#",
1358 local: "EnergySource",
1359 qualified: "EnergySource",
1360 super_class: Some(94),
1361 concrete: true,
1362 origins: &["EQ", "SC", "SSH"],
1363 comment: "A generic equivalent for an energy supplier on a transmission or distribution voltage level.",
1364 attrs: &[
1365 AttrDef { id: "EnergySource.EnergySchedulingType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "EnergySchedulingType", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "Energy Scheduling Type of an Energy Source." },
1366 AttrDef { id: "EnergySource.activePower", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "High voltage source active injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for steady state solutions." },
1367 AttrDef { id: "EnergySource.nominalVoltage", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Phase-to-phase nominal voltage." },
1368 AttrDef { id: "EnergySource.pMax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "This is the maximum active power that can be produced by the source. Load sign convention is used, i.e. positive sign means flow out from a TopologicalNode (bus) into the conducting equipment." },
1369 AttrDef { id: "EnergySource.pMin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "This is the minimum active power that can be produced by the source. Load sign convention is used, i.e. positive sign means flow out from a TopologicalNode (bus) into the conducting equipment." },
1370 AttrDef { id: "EnergySource.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Positive sequence Thevenin resistance." },
1371 AttrDef { id: "EnergySource.r0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence Thevenin resistance." },
1372 AttrDef { id: "EnergySource.reactivePower", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "High voltage source reactive injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for steady state solutions." },
1373 AttrDef { id: "EnergySource.rn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Negative sequence Thevenin resistance." },
1374 AttrDef { id: "EnergySource.voltageAngle", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleRadians", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Phase angle of a-phase open circuit used when voltage characteristics need to be imposed at the node associated with the terminal of the energy source, such as when voltages and angles from the transmission level are used as input to the distribution network. The attribute shall be a positive value or zero." },
1375 AttrDef { id: "EnergySource.voltageMagnitude", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Phase-to-phase open circuit voltage magnitude used when voltage characteristics need to be imposed at the node associated with the terminal of the energy source, such as when voltages and angles from the transmission level are used as input to the distribution network. The attribute shall be a positive value or zero." },
1376 AttrDef { id: "EnergySource.x", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Positive sequence Thevenin reactance." },
1377 AttrDef { id: "EnergySource.x0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence Thevenin reactance." },
1378 AttrDef { id: "EnergySource.xn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Negative sequence Thevenin reactance." },
1379 ],
1380 },
1381 ClassDef {
1382 ns: "http://iec.ch/TC57/CIM100#",
1383 local: "Equipment",
1384 qualified: "Equipment",
1385 super_class: Some(282),
1386 concrete: true,
1387 origins: &["EQ", "DY", "EQBD", "SC", "SSH"],
1388 comment: "The parts of a power system that are physical devices, electronic or mechanical.",
1389 attrs: &[
1390 AttrDef { id: "Equipment.EquipmentContainer", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "EquipmentContainer", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "Container of this equipment." },
1391 AttrDef { id: "Equipment.OperationalLimitSet", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "OperationalLimitSet", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The operational limit sets associated with this equipment." },
1392 AttrDef { id: "Equipment.aggregate", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["EQ"], comment: "The aggregate flag provides an alternative way of representing an aggregated (equivalent) element. It is applicable in cases when the dedicated classes for equivalent equipment do not have all of the attributes necessary to represent the required level of detail. In case the flag is set to “true” the single instance of equipment represents multiple pieces of equipment that have been modelled together as an aggregate equivalent obtained by a network reduction procedure. Examples would be power transformers or synchronous machines operating in parallel modelled as a single aggregate power transformer or aggregate synchronous machine. The attribute is not used for EquivalentBranch, EquivalentShunt and EquivalentInjection." },
1393 AttrDef { id: "Equipment.inService", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["SSH"], comment: "Specifies the availability of the equipment. True means the equipment is available for topology processing, which determines if the equipment is energized or not. False means that the equipment is treated by network applications as if it is not in the model." },
1394 AttrDef { id: "Equipment.normallyInService", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["EQ"], comment: "Specifies the availability of the equipment under normal operating conditions. True means the equipment is available for topology processing, which determines if the equipment is energized or not. False means that the equipment is treated by network applications as if it is not in the model." },
1395 ],
1396 },
1397 ClassDef {
1398 ns: "http://iec.ch/TC57/CIM100#",
1399 local: "EquipmentContainer",
1400 qualified: "EquipmentContainer",
1401 super_class: Some(43),
1402 concrete: false,
1403 origins: &["EQ", "EQBD"],
1404 comment: "A modelling construct to provide a root class for containing equipment.",
1405 attrs: &[
1406 AttrDef { id: "EquipmentContainer.Equipments", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Equipment", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "Contained equipment." },
1407 ],
1408 },
1409 ClassDef {
1410 ns: "http://iec.ch/TC57/CIM100#",
1411 local: "EquivalentBranch",
1412 qualified: "EquivalentBranch",
1413 super_class: Some(101),
1414 concrete: true,
1415 origins: &["EQ", "SC"],
1416 comment: "The class represents equivalent branches. In cases where a transformer phase shift is modelled and the EquivalentBranch is spanning the same nodes, the impedance quantities for the EquivalentBranch shall consider the needed phase shift.",
1417 attrs: &[
1418 AttrDef { id: "EquivalentBranch.negativeR12", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Negative sequence series resistance from terminal sequence 1 to terminal sequence 2. Used for short circuit data exchange according to IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange." },
1419 AttrDef { id: "EquivalentBranch.negativeR21", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Negative sequence series resistance from terminal sequence 2 to terminal sequence 1. Used for short circuit data exchange according to IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange." },
1420 AttrDef { id: "EquivalentBranch.negativeX12", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Negative sequence series reactance from terminal sequence 1 to terminal sequence 2. Used for short circuit data exchange according to IEC 60909. Usage : EquivalentBranch is a result of network reduction prior to the data exchange." },
1421 AttrDef { id: "EquivalentBranch.negativeX21", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Negative sequence series reactance from terminal sequence 2 to terminal sequence 1. Used for short circuit data exchange according to IEC 60909. Usage: EquivalentBranch is a result of network reduction prior to the data exchange." },
1422 AttrDef { id: "EquivalentBranch.positiveR12", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Positive sequence series resistance from terminal sequence 1 to terminal sequence 2 . Used for short circuit data exchange according to IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange." },
1423 AttrDef { id: "EquivalentBranch.positiveR21", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Positive sequence series resistance from terminal sequence 2 to terminal sequence 1. Used for short circuit data exchange according to IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange." },
1424 AttrDef { id: "EquivalentBranch.positiveX12", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Positive sequence series reactance from terminal sequence 1 to terminal sequence 2. Used for short circuit data exchange according to IEC 60909. Usage : EquivalentBranch is a result of network reduction prior to the data exchange." },
1425 AttrDef { id: "EquivalentBranch.positiveX21", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Positive sequence series reactance from terminal sequence 2 to terminal sequence 1. Used for short circuit data exchange according to IEC 60909. Usage : EquivalentBranch is a result of network reduction prior to the data exchange." },
1426 AttrDef { id: "EquivalentBranch.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Positive sequence series resistance of the reduced branch." },
1427 AttrDef { id: "EquivalentBranch.r21", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Resistance from terminal sequence 2 to terminal sequence 1 .Used for steady state power flow. This attribute is optional and represent unbalanced network such as off-nominal phase shifter. If only EquivalentBranch.r is given, then EquivalentBranch.r21 is assumed equal to EquivalentBranch.r. Usage rule : EquivalentBranch is a result of network reduction prior to the data exchange." },
1428 AttrDef { id: "EquivalentBranch.x", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Positive sequence series reactance of the reduced branch." },
1429 AttrDef { id: "EquivalentBranch.x21", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Reactance from terminal sequence 2 to terminal sequence 1. Used for steady state power flow. This attribute is optional and represents an unbalanced network such as off-nominal phase shifter. If only EquivalentBranch.x is given, then EquivalentBranch.x21 is assumed equal to EquivalentBranch.x. Usage rule: EquivalentBranch is a result of network reduction prior to the data exchange." },
1430 AttrDef { id: "EquivalentBranch.zeroR12", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence series resistance from terminal sequence 1 to terminal sequence 2. Used for short circuit data exchange according to IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange." },
1431 AttrDef { id: "EquivalentBranch.zeroR21", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence series resistance from terminal sequence 2 to terminal sequence 1. Used for short circuit data exchange according to IEC 60909. Usage : EquivalentBranch is a result of network reduction prior to the data exchange." },
1432 AttrDef { id: "EquivalentBranch.zeroX12", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence series reactance from terminal sequence 1 to terminal sequence 2. Used for short circuit data exchange according to IEC 60909. Usage : EquivalentBranch is a result of network reduction prior to the data exchange." },
1433 AttrDef { id: "EquivalentBranch.zeroX21", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence series reactance from terminal sequence 2 to terminal sequence 1. Used for short circuit data exchange according to IEC 60909. Usage : EquivalentBranch is a result of network reduction prior to the data exchange." },
1434 ],
1435 },
1436 ClassDef {
1437 ns: "http://iec.ch/TC57/CIM100#",
1438 local: "EquivalentEquipment",
1439 qualified: "EquivalentEquipment",
1440 super_class: Some(37),
1441 concrete: false,
1442 origins: &["EQ", "SC", "SSH"],
1443 comment: "The class represents equivalent objects that are the result of a network reduction. The class is the base for equivalent objects of different types.",
1444 attrs: &[
1445 AttrDef { id: "EquivalentEquipment.EquivalentNetwork", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "EquivalentNetwork", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The equivalent where the reduced model belongs." },
1446 ],
1447 },
1448 ClassDef {
1449 ns: "http://iec.ch/TC57/CIM100#",
1450 local: "EquivalentInjection",
1451 qualified: "EquivalentInjection",
1452 super_class: Some(101),
1453 concrete: true,
1454 origins: &["EQ", "SC", "SSH"],
1455 comment: "This class represents equivalent injections (generation or load). Voltage regulation is allowed only at the point of connection.",
1456 attrs: &[
1457 AttrDef { id: "EquivalentInjection.ReactiveCapabilityCurve", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ReactiveCapabilityCurve", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The reactive capability curve used by this equivalent injection." },
1458 AttrDef { id: "EquivalentInjection.maxP", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Maximum active power of the injection." },
1459 AttrDef { id: "EquivalentInjection.maxQ", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Maximum reactive power of the injection. Used for modelling of infeed for load flow exchange. Not used for short circuit modelling. If maxQ and minQ are not used ReactiveCapabilityCurve can be used." },
1460 AttrDef { id: "EquivalentInjection.minP", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Minimum active power of the injection." },
1461 AttrDef { id: "EquivalentInjection.minQ", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Minimum reactive power of the injection. Used for modelling of infeed for load flow exchange. Not used for short circuit modelling. If maxQ and minQ are not used ReactiveCapabilityCurve can be used." },
1462 AttrDef { id: "EquivalentInjection.p", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Equivalent active power injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for steady state solutions." },
1463 AttrDef { id: "EquivalentInjection.q", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Equivalent reactive power injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for steady state solutions." },
1464 AttrDef { id: "EquivalentInjection.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Positive sequence resistance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a result of network reduction prior to the data exchange." },
1465 AttrDef { id: "EquivalentInjection.r0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence resistance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a result of network reduction prior to the data exchange." },
1466 AttrDef { id: "EquivalentInjection.r2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Negative sequence resistance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a result of network reduction prior to the data exchange." },
1467 AttrDef { id: "EquivalentInjection.regulationCapability", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["EQ"], comment: "Specifies whether or not the EquivalentInjection has the capability to regulate the local voltage. If true the EquivalentInjection can regulate. If false the EquivalentInjection cannot regulate. ReactiveCapabilityCurve can only be associated with EquivalentInjection if the flag is true." },
1468 AttrDef { id: "EquivalentInjection.regulationStatus", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["SSH"], comment: "Specifies the regulation status of the EquivalentInjection. True is regulating. False is not regulating." },
1469 AttrDef { id: "EquivalentInjection.regulationTarget", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "The target voltage for voltage regulation. The attribute shall be a positive value." },
1470 AttrDef { id: "EquivalentInjection.x", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Positive sequence reactance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a result of network reduction prior to the data exchange." },
1471 AttrDef { id: "EquivalentInjection.x0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence reactance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a result of network reduction prior to the data exchange." },
1472 AttrDef { id: "EquivalentInjection.x2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Negative sequence reactance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a result of network reduction prior to the data exchange." },
1473 ],
1474 },
1475 ClassDef {
1476 ns: "http://iec.ch/TC57/CIM100#",
1477 local: "EquivalentNetwork",
1478 qualified: "EquivalentNetwork",
1479 super_class: Some(43),
1480 concrete: true,
1481 origins: &["EQ"],
1482 comment: "A class that groups electrical equivalents, including internal nodes, of a network that has been reduced. The ConnectivityNodes contained in the equivalent are intended to reflect internal nodes of the equivalent. The boundary Connectivity nodes where the equivalent connects outside itself are not contained by the equivalent.",
1483 attrs: &[
1484 AttrDef { id: "EquivalentNetwork.EquivalentEquipments", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "EquivalentEquipment", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The associated reduced equivalents." },
1485 ],
1486 },
1487 ClassDef {
1488 ns: "http://iec.ch/TC57/CIM100#",
1489 local: "EquivalentShunt",
1490 qualified: "EquivalentShunt",
1491 super_class: Some(101),
1492 concrete: true,
1493 origins: &["EQ"],
1494 comment: "The class represents equivalent shunts.",
1495 attrs: &[
1496 AttrDef { id: "EquivalentShunt.b", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Susceptance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Positive sequence shunt susceptance." },
1497 AttrDef { id: "EquivalentShunt.g", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Conductance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Positive sequence shunt conductance." },
1498 ],
1499 },
1500 ClassDef {
1501 ns: "http://iec.ch/TC57/CIM100#",
1502 local: "ExcAC1A",
1503 qualified: "ExcAC1A",
1504 super_class: Some(161),
1505 concrete: true,
1506 origins: &["DY"],
1507 comment: "Modified IEEE AC1A alternator-supplied rectifier excitation system with different rate feedback source.",
1508 attrs: &[
1509 AttrDef { id: "ExcAC1A.hvlvgates", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Indicates if both HV gate and LV gate are active (HVLVgates). true = gates are used false = gates are not used. Typical value = true." },
1510 AttrDef { id: "ExcAC1A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (Ka) (> 0). Typical value = 400." },
1511 AttrDef { id: "ExcAC1A.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (Kc) (>= 0). Typical value = 0,2." },
1512 AttrDef { id: "ExcAC1A.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Demagnetizing factor, a function of exciter alternator reactances (Kd) (>= 0). Typical value = 0,38." },
1513 AttrDef { id: "ExcAC1A.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (Ke). Typical value = 1." },
1514 AttrDef { id: "ExcAC1A.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gains (Kf) (>= 0). Typical value = 0,03." },
1515 AttrDef { id: "ExcAC1A.kf1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient to allow different usage of the model (Kf1) (>= 0). Typical value = 0." },
1516 AttrDef { id: "ExcAC1A.kf2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient to allow different usage of the model (Kf2) (>= 0). Typical value = 1." },
1517 AttrDef { id: "ExcAC1A.ks", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient to allow different usage of the model-speed coefficient (Ks) (>= 0). Typical value = 0." },
1518 AttrDef { id: "ExcAC1A.seve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Ve1, back of commutating reactance (Se[Ve1]) (>= 0). Typical value = 0,1." },
1519 AttrDef { id: "ExcAC1A.seve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Ve2, back of commutating reactance (Se[Ve2]) (>= 0). Typical value = 0,03." },
1520 AttrDef { id: "ExcAC1A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Ta) (> 0). Typical value = 0,02." },
1521 AttrDef { id: "ExcAC1A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tb) (>= 0). Typical value = 0." },
1522 AttrDef { id: "ExcAC1A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tc) (>= 0). Typical value = 0." },
1523 AttrDef { id: "ExcAC1A.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (Te) (> 0). Typical value = 0,8." },
1524 AttrDef { id: "ExcAC1A.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (Tf) (> 0). Typical value = 1." },
1525 AttrDef { id: "ExcAC1A.vamax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (Vamax) (> 0). Typical value = 14,5." },
1526 AttrDef { id: "ExcAC1A.vamin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (Vamin) (< 0). Typical value = -14,5." },
1527 AttrDef { id: "ExcAC1A.ve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (Ve1) (> 0). Typical value = 4,18." },
1528 AttrDef { id: "ExcAC1A.ve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (Ve2) (> 0). Typical value = 3,14." },
1529 AttrDef { id: "ExcAC1A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator outputs (Vrmax) (> 0). Typical value = 6,03." },
1530 AttrDef { id: "ExcAC1A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator outputs (Vrmin) (< 0). Typical value = -5,43." },
1531 ],
1532 },
1533 ClassDef {
1534 ns: "http://iec.ch/TC57/CIM100#",
1535 local: "ExcAC2A",
1536 qualified: "ExcAC2A",
1537 super_class: Some(161),
1538 concrete: true,
1539 origins: &["DY"],
1540 comment: "Modified IEEE AC2A alternator-supplied rectifier excitation system with different field current limit.",
1541 attrs: &[
1542 AttrDef { id: "ExcAC2A.hvgate", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Indicates if HV gate is active (HVgate). true = gate is used false = gate is not used. Typical value = true." },
1543 AttrDef { id: "ExcAC2A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (Ka) (> 0). Typical value = 400." },
1544 AttrDef { id: "ExcAC2A.kb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Second stage regulator gain (Kb) (> 0). Exciter field current controller gain. Typical value = 25." },
1545 AttrDef { id: "ExcAC2A.kb1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Second stage regulator gain (Kb1). It is exciter field current controller gain used as alternative to Kb to represent a variant of the ExcAC2A model. Typical value = 25." },
1546 AttrDef { id: "ExcAC2A.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (Kc) (>= 0). Typical value = 0,28." },
1547 AttrDef { id: "ExcAC2A.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Demagnetizing factor, a function of exciter alternator reactances (Kd) (>= 0). Typical value = 0,35." },
1548 AttrDef { id: "ExcAC2A.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (Ke). Typical value = 1." },
1549 AttrDef { id: "ExcAC2A.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gains (Kf) (>= 0). Typical value = 0,03." },
1550 AttrDef { id: "ExcAC2A.kh", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field current feedback gain (Kh) (>= 0). Typical value = 1." },
1551 AttrDef { id: "ExcAC2A.kl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field current limiter gain (Kl). Typical value = 10." },
1552 AttrDef { id: "ExcAC2A.kl1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient to allow different usage of the model (Kl1). Typical value = 1." },
1553 AttrDef { id: "ExcAC2A.ks", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient to allow different usage of the model-speed coefficient (Ks) (>= 0). Typical value = 0." },
1554 AttrDef { id: "ExcAC2A.lvgate", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Indicates if LV gate is active (LVgate). true = gate is used false = gate is not used. Typical value = true." },
1555 AttrDef { id: "ExcAC2A.seve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Ve1, back of commutating reactance (Se[Ve1]) (>= 0). Typical value = 0,037." },
1556 AttrDef { id: "ExcAC2A.seve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Ve2, back of commutating reactance (Se[Ve2]) (>= 0). Typical value = 0,012." },
1557 AttrDef { id: "ExcAC2A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Ta) (> 0). Typical value = 0,02." },
1558 AttrDef { id: "ExcAC2A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tb) (>= 0). Typical value = 0." },
1559 AttrDef { id: "ExcAC2A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tc) (>= 0). Typical value = 0." },
1560 AttrDef { id: "ExcAC2A.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (Te) (> 0). Typical value = 0,6." },
1561 AttrDef { id: "ExcAC2A.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (Tf) (> 0). Typical value = 1." },
1562 AttrDef { id: "ExcAC2A.vamax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (Vamax) (> 0). Typical value = 8." },
1563 AttrDef { id: "ExcAC2A.vamin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (Vamin) (< 0). Typical value = -8." },
1564 AttrDef { id: "ExcAC2A.ve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (Ve1) (> 0). Typical value = 4,4." },
1565 AttrDef { id: "ExcAC2A.ve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (Ve2) (> 0). Typical value = 3,3." },
1566 AttrDef { id: "ExcAC2A.vfemax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field current limit reference (Vfemax) (>= 0). Typical value = 4,4." },
1567 AttrDef { id: "ExcAC2A.vlr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum exciter field current (Vlr) (> 0). Typical value = 4,4." },
1568 AttrDef { id: "ExcAC2A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator outputs (Vrmax) (> 0). Typical value = 105." },
1569 AttrDef { id: "ExcAC2A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator outputs (Vrmin) (< 0). Typical value = -95." },
1570 ],
1571 },
1572 ClassDef {
1573 ns: "http://iec.ch/TC57/CIM100#",
1574 local: "ExcAC3A",
1575 qualified: "ExcAC3A",
1576 super_class: Some(161),
1577 concrete: true,
1578 origins: &["DY"],
1579 comment: "Modified IEEE AC3A alternator-supplied rectifier excitation system with different field current limit.",
1580 attrs: &[
1581 AttrDef { id: "ExcAC3A.efdn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Value of Efd at which feedback gain changes (Efdn) (> 0). Typical value = 2,36." },
1582 AttrDef { id: "ExcAC3A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (Ka) (> 0). Typical value = 45,62." },
1583 AttrDef { id: "ExcAC3A.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (Kc) (>= 0). Typical value = 0,104." },
1584 AttrDef { id: "ExcAC3A.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Demagnetizing factor, a function of exciter alternator reactances (Kd) (>= 0). Typical value = 0,499." },
1585 AttrDef { id: "ExcAC3A.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (Ke). Typical value = 1." },
1586 AttrDef { id: "ExcAC3A.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gains (Kf) (>= 0). Typical value = 0,143." },
1587 AttrDef { id: "ExcAC3A.kf1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient to allow different usage of the model (Kf1). Typical value = 1." },
1588 AttrDef { id: "ExcAC3A.kf2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient to allow different usage of the model (Kf2). Typical value = 0." },
1589 AttrDef { id: "ExcAC3A.klv", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain used in the minimum field voltage limiter loop (Klv). Typical value = 0,194." },
1590 AttrDef { id: "ExcAC3A.kn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gain (Kn) (>= 0). Typical value =0,05." },
1591 AttrDef { id: "ExcAC3A.kr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Constant associated with regulator and alternator field power supply (Kr) (> 0). Typical value =3,77." },
1592 AttrDef { id: "ExcAC3A.ks", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient to allow different usage of the model-speed coefficient (Ks). Typical value = 0." },
1593 AttrDef { id: "ExcAC3A.seve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Ve1, back of commutating reactance (Se[Ve1]) (>= 0). Typical value = 1,143." },
1594 AttrDef { id: "ExcAC3A.seve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Ve2, back of commutating reactance (Se[Ve2]) (>= 0). Typical value = 0,1." },
1595 AttrDef { id: "ExcAC3A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Ta) (> 0). Typical value = 0,013." },
1596 AttrDef { id: "ExcAC3A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tb) (>= 0). Typical value = 0." },
1597 AttrDef { id: "ExcAC3A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tc) (>= 0). Typical value = 0." },
1598 AttrDef { id: "ExcAC3A.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (Te) (> 0). Typical value = 1,17." },
1599 AttrDef { id: "ExcAC3A.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (Tf) (> 0). Typical value = 1." },
1600 AttrDef { id: "ExcAC3A.vamax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (Vamax) (> 0). Typical value = 1." },
1601 AttrDef { id: "ExcAC3A.vamin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (Vamin) (< 0). Typical value = -0,95." },
1602 AttrDef { id: "ExcAC3A.ve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (Ve1) (> 0). Typical value = 6.24." },
1603 AttrDef { id: "ExcAC3A.ve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (Ve2) (> 0). Typical value = 4,68." },
1604 AttrDef { id: "ExcAC3A.vemin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum exciter voltage output (Vemin) (<= 0). Typical value = 0." },
1605 AttrDef { id: "ExcAC3A.vfemax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field current limit reference (Vfemax) (>= 0). Typical value = 16." },
1606 AttrDef { id: "ExcAC3A.vlv", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field voltage used in the minimum field voltage limiter loop (Vlv). Typical value = 0,79." },
1607 ],
1608 },
1609 ClassDef {
1610 ns: "http://iec.ch/TC57/CIM100#",
1611 local: "ExcAC4A",
1612 qualified: "ExcAC4A",
1613 super_class: Some(161),
1614 concrete: true,
1615 origins: &["DY"],
1616 comment: "Modified IEEE AC4A alternator-supplied rectifier excitation system with different minimum controller output.",
1617 attrs: &[
1618 AttrDef { id: "ExcAC4A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (Ka) (> 0). Typical value = 200." },
1619 AttrDef { id: "ExcAC4A.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (Kc) (>= 0). Typical value = 0." },
1620 AttrDef { id: "ExcAC4A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Ta) (> 0). Typical value = 0,015." },
1621 AttrDef { id: "ExcAC4A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tb) (>= 0). Typical value = 10." },
1622 AttrDef { id: "ExcAC4A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tc) (>= 0). Typical value = 1." },
1623 AttrDef { id: "ExcAC4A.vimax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator input limit (Vimax) (> 0). Typical value = 10." },
1624 AttrDef { id: "ExcAC4A.vimin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator input limit (Vimin) (< 0). Typical value = -10." },
1625 AttrDef { id: "ExcAC4A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (Vrmax) (> 0). Typical value = 5,64." },
1626 AttrDef { id: "ExcAC4A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (Vrmin) (< 0). Typical value = -4,53." },
1627 ],
1628 },
1629 ClassDef {
1630 ns: "http://iec.ch/TC57/CIM100#",
1631 local: "ExcAC5A",
1632 qualified: "ExcAC5A",
1633 super_class: Some(161),
1634 concrete: true,
1635 origins: &["DY"],
1636 comment: "Modified IEEE AC5A alternator-supplied rectifier excitation system with different minimum controller output.",
1637 attrs: &[
1638 AttrDef { id: "ExcAC5A.a", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient to allow different usage of the model (a). Typical value = 1." },
1639 AttrDef { id: "ExcAC5A.efd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter voltage at which exciter saturation is defined (Efd1) (> 0). Typical value = 5,6." },
1640 AttrDef { id: "ExcAC5A.efd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter voltage at which exciter saturation is defined (Efd2) (> 0). Typical value = 4,2." },
1641 AttrDef { id: "ExcAC5A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (Ka) (> 0). Typical value = 400." },
1642 AttrDef { id: "ExcAC5A.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (Ke). Typical value = 1." },
1643 AttrDef { id: "ExcAC5A.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gains (Kf) (>= 0). Typical value = 0,03." },
1644 AttrDef { id: "ExcAC5A.ks", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient to allow different usage of the model-speed coefficient (Ks). Typical value = 0." },
1645 AttrDef { id: "ExcAC5A.seefd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Efd1 (Se[Efd1]) (>= 0). Typical value = 0,86." },
1646 AttrDef { id: "ExcAC5A.seefd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Efd2 (Se[Efd2]) (>= 0). Typical value = 0,5." },
1647 AttrDef { id: "ExcAC5A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Ta) (> 0). Typical value = 0,02." },
1648 AttrDef { id: "ExcAC5A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tb) (>= 0). Typical value = 0." },
1649 AttrDef { id: "ExcAC5A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tc) (>= 0). Typical value = 0." },
1650 AttrDef { id: "ExcAC5A.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (Te) (> 0). Typical value = 0,8." },
1651 AttrDef { id: "ExcAC5A.tf1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (Tf1) (> 0). Typical value = 1." },
1652 AttrDef { id: "ExcAC5A.tf2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (Tf2) (>= 0). Typical value = 0,8." },
1653 AttrDef { id: "ExcAC5A.tf3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (Tf3) (>= 0). Typical value = 0." },
1654 AttrDef { id: "ExcAC5A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (Vrmax) (> 0). Typical value = 7,3." },
1655 AttrDef { id: "ExcAC5A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (Vrmin) (< 0). Typical value =-7,3." },
1656 ],
1657 },
1658 ClassDef {
1659 ns: "http://iec.ch/TC57/CIM100#",
1660 local: "ExcAC6A",
1661 qualified: "ExcAC6A",
1662 super_class: Some(161),
1663 concrete: true,
1664 origins: &["DY"],
1665 comment: "Modified IEEE AC6A alternator-supplied rectifier excitation system with speed input.",
1666 attrs: &[
1667 AttrDef { id: "ExcAC6A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (Ka) (> 0). Typical value = 536." },
1668 AttrDef { id: "ExcAC6A.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (Kc) (>= 0). Typical value = 0,173." },
1669 AttrDef { id: "ExcAC6A.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Demagnetizing factor, a function of exciter alternator reactances (Kd) (>= 0). Typical value = 1,91." },
1670 AttrDef { id: "ExcAC6A.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (Ke). Typical value = 1,6." },
1671 AttrDef { id: "ExcAC6A.kh", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field current limiter gain (Kh) (>= 0). Typical value = 92." },
1672 AttrDef { id: "ExcAC6A.ks", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient to allow different usage of the model-speed coefficient (Ks). Typical value = 0." },
1673 AttrDef { id: "ExcAC6A.seve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Ve1, back of commutating reactance (Se[Ve1]) (>= 0). Typical value = 0,214." },
1674 AttrDef { id: "ExcAC6A.seve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Ve2, back of commutating reactance (Se[Ve2]) (>= 0). Typical value = 0,044." },
1675 AttrDef { id: "ExcAC6A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Ta) (>= 0). Typical value = 0,086." },
1676 AttrDef { id: "ExcAC6A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tb) (>= 0). Typical value = 9." },
1677 AttrDef { id: "ExcAC6A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tc) (>= 0). Typical value = 3." },
1678 AttrDef { id: "ExcAC6A.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (Te) (> 0). Typical value = 1." },
1679 AttrDef { id: "ExcAC6A.th", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field current limiter time constant (Th) (> 0). Typical value = 0,08." },
1680 AttrDef { id: "ExcAC6A.tj", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field current limiter time constant (Tj) (>= 0). Typical value = 0,02." },
1681 AttrDef { id: "ExcAC6A.tk", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tk) (>= 0). Typical value = 0,18." },
1682 AttrDef { id: "ExcAC6A.vamax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (Vamax) (> 0). Typical value = 75." },
1683 AttrDef { id: "ExcAC6A.vamin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (Vamin) (< 0). Typical value = -75." },
1684 AttrDef { id: "ExcAC6A.ve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (Ve1) (> 0). Typical value = 7,4." },
1685 AttrDef { id: "ExcAC6A.ve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (Ve2) (> 0). Typical value = 5,55." },
1686 AttrDef { id: "ExcAC6A.vfelim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field current limit reference (Vfelim) (> 0). Typical value = 19." },
1687 AttrDef { id: "ExcAC6A.vhmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum field current limiter signal reference (Vhmax) (> 0). Typical value = 75." },
1688 AttrDef { id: "ExcAC6A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (Vrmax) (> 0). Typical value = 44." },
1689 AttrDef { id: "ExcAC6A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (Vrmin) (< 0). Typical value = -36." },
1690 ],
1691 },
1692 ClassDef {
1693 ns: "http://iec.ch/TC57/CIM100#",
1694 local: "ExcAC8B",
1695 qualified: "ExcAC8B",
1696 super_class: Some(161),
1697 concrete: true,
1698 origins: &["DY"],
1699 comment: "Modified IEEE AC8B alternator-supplied rectifier excitation system with speed input and input limiter.",
1700 attrs: &[
1701 AttrDef { id: "ExcAC8B.inlim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Input limiter indicator. true = input limiter Vimax and Vimin is considered false = input limiter Vimax and Vimin is not considered. Typical value = true." },
1702 AttrDef { id: "ExcAC8B.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (Ka) (> 0). Typical value = 1." },
1703 AttrDef { id: "ExcAC8B.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (Kc) (>= 0). Typical value = 0,55." },
1704 AttrDef { id: "ExcAC8B.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Demagnetizing factor, a function of exciter alternator reactances (Kd) (>= 0). Typical value = 1,1." },
1705 AttrDef { id: "ExcAC8B.kdr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator derivative gain (Kdr) (>= 0). Typical value = 10." },
1706 AttrDef { id: "ExcAC8B.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (Ke). Typical value = 1." },
1707 AttrDef { id: "ExcAC8B.kir", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator integral gain (Kir) (>= 0). Typical value = 5." },
1708 AttrDef { id: "ExcAC8B.kpr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator proportional gain (Kpr) (> 0 if ExcAC8B.kir = 0). Typical value = 80." },
1709 AttrDef { id: "ExcAC8B.ks", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient to allow different usage of the model-speed coefficient (Ks). Typical value = 0." },
1710 AttrDef { id: "ExcAC8B.pidlim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "PID limiter indicator. true = input limiter Vpidmax and Vpidmin is considered false = input limiter Vpidmax and Vpidmin is not considered. Typical value = true." },
1711 AttrDef { id: "ExcAC8B.seve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Ve1, back of commutating reactance (Se[Ve1]) (>= 0). Typical value = 0,3." },
1712 AttrDef { id: "ExcAC8B.seve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Ve2, back of commutating reactance (Se[Ve2]) (>= 0). Typical value = 3." },
1713 AttrDef { id: "ExcAC8B.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Ta) (>= 0). Typical value = 0." },
1714 AttrDef { id: "ExcAC8B.tdr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant (Tdr) (> 0 if ExcAC8B.kdr > 0). Typical value = 0,1." },
1715 AttrDef { id: "ExcAC8B.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (Te) (> 0). Typical value = 1,2." },
1716 AttrDef { id: "ExcAC8B.telim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Selector for the limiter on the block (1/sTe). See diagram for meaning of true and false. Typical value = false." },
1717 AttrDef { id: "ExcAC8B.ve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (Ve1) (> 0). Typical value = 6,5." },
1718 AttrDef { id: "ExcAC8B.ve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (Ve2) (> 0). Typical value = 9." },
1719 AttrDef { id: "ExcAC8B.vemin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum exciter voltage output (Vemin) (<= 0). Typical value = 0." },
1720 AttrDef { id: "ExcAC8B.vfemax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field current limit reference (Vfemax). Typical value = 6." },
1721 AttrDef { id: "ExcAC8B.vimax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input signal maximum (Vimax) (> ExcAC8B.vimin). Typical value = 35." },
1722 AttrDef { id: "ExcAC8B.vimin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input signal minimum (Vimin) (< ExcAC8B.vimax). Typical value = -10." },
1723 AttrDef { id: "ExcAC8B.vpidmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PID maximum controller output (Vpidmax) (> ExcAC8B.vpidmin). Typical value = 35." },
1724 AttrDef { id: "ExcAC8B.vpidmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PID minimum controller output (Vpidmin) (< ExcAC8B.vpidmax). Typical value = -10." },
1725 AttrDef { id: "ExcAC8B.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (Vrmax) (> 0). Typical value = 35." },
1726 AttrDef { id: "ExcAC8B.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (Vrmin) (< 0). Typical value = 0." },
1727 AttrDef { id: "ExcAC8B.vtmult", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Multiply by generator's terminal voltage indicator. true =the limits Vrmax and Vrmin are multiplied by the generator’s terminal voltage to represent a thyristor power stage fed from the generator terminals false = limits are not multiplied by generator's terminal voltage. Typical value = false." },
1728 ],
1729 },
1730 ClassDef {
1731 ns: "http://iec.ch/TC57/CIM100#",
1732 local: "ExcANS",
1733 qualified: "ExcANS",
1734 super_class: Some(161),
1735 concrete: true,
1736 origins: &["DY"],
1737 comment: "Italian excitation system. It represents static field voltage or excitation current feedback excitation system.",
1738 attrs: &[
1739 AttrDef { id: "ExcANS.blint", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["DY"], comment: "Governor control flag (BLINT). 0 = lead-lag regulator 1 = proportional integral regulator. Typical value = 0." },
1740 AttrDef { id: "ExcANS.ifmn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum exciter current (IFMN). Typical value = -5,2." },
1741 AttrDef { id: "ExcANS.ifmx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum exciter current (IFMX). Typical value = 6,5." },
1742 AttrDef { id: "ExcANS.k2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter gain (K2). Typical value = 20." },
1743 AttrDef { id: "ExcANS.k3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "AVR gain (K3). Typical value = 1000." },
1744 AttrDef { id: "ExcANS.kce", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Ceiling factor (KCE). Typical value = 1." },
1745 AttrDef { id: "ExcANS.krvecc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["DY"], comment: "Feedback enabling (KRVECC). 0 = open loop control 1 = closed loop control. Typical value = 1." },
1746 AttrDef { id: "ExcANS.kvfif", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["DY"], comment: "Rate feedback signal flag (KVFIF). 0 = output voltage of the exciter 1 = exciter field current. Typical value = 0." },
1747 AttrDef { id: "ExcANS.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T1) (>= 0). Typical value = 20." },
1748 AttrDef { id: "ExcANS.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T2) (>= 0). Typical value = 0,05." },
1749 AttrDef { id: "ExcANS.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T3) (>= 0). Typical value = 1,6." },
1750 AttrDef { id: "ExcANS.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant (TB) (>= 0). Typical value = 0,04." },
1751 AttrDef { id: "ExcANS.vrmn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum AVR output (VRMN). Typical value = -5,2." },
1752 AttrDef { id: "ExcANS.vrmx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum AVR output (VRMX). Typical value = 6,5." },
1753 ],
1754 },
1755 ClassDef {
1756 ns: "http://iec.ch/TC57/CIM100#",
1757 local: "ExcAVR1",
1758 qualified: "ExcAVR1",
1759 super_class: Some(161),
1760 concrete: true,
1761 origins: &["DY"],
1762 comment: "Italian excitation system corresponding to IEEE (1968) type 1 model. It represents an exciter dynamo and electromechanical regulator.",
1763 attrs: &[
1764 AttrDef { id: "ExcAVR1.e1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field voltage value 1 (E1). Typical value = 4.18." },
1765 AttrDef { id: "ExcAVR1.e2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field voltage value 2 (E2). Typical value = 3,14." },
1766 AttrDef { id: "ExcAVR1.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "AVR gain (KA). Typical value = 500." },
1767 AttrDef { id: "ExcAVR1.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rate feedback gain (KF). Typical value = 0,12." },
1768 AttrDef { id: "ExcAVR1.se1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Saturation factor at E1 (S[E1]). Typical value = 0,1." },
1769 AttrDef { id: "ExcAVR1.se2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Saturation factor at E2 (S[E2]). Typical value = 0,03." },
1770 AttrDef { id: "ExcAVR1.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "AVR time constant (TA) (>= 0). Typical value = 0,2." },
1771 AttrDef { id: "ExcAVR1.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "AVR time constant (TB) (>= 0). Typical value = 0." },
1772 AttrDef { id: "ExcAVR1.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant (TE) (>= 0). Typical value = 1." },
1773 AttrDef { id: "ExcAVR1.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rate feedback time constant (TF) (>= 0). Typical value = 1." },
1774 AttrDef { id: "ExcAVR1.vrmn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum AVR output (VRMN). Typical value = -6." },
1775 AttrDef { id: "ExcAVR1.vrmx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum AVR output (VRMX). Typical value = 7." },
1776 ],
1777 },
1778 ClassDef {
1779 ns: "http://iec.ch/TC57/CIM100#",
1780 local: "ExcAVR2",
1781 qualified: "ExcAVR2",
1782 super_class: Some(161),
1783 concrete: true,
1784 origins: &["DY"],
1785 comment: "Italian excitation system corresponding to IEEE (1968) type 2 model. It represents an alternator and rotating diodes and electromechanic voltage regulators.",
1786 attrs: &[
1787 AttrDef { id: "ExcAVR2.e1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field voltage value 1 (E1). Typical value = 4,18." },
1788 AttrDef { id: "ExcAVR2.e2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field voltage value 2 (E2). Typical value = 3,14." },
1789 AttrDef { id: "ExcAVR2.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "AVR gain (KA). Typical value = 500." },
1790 AttrDef { id: "ExcAVR2.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rate feedback gain (KF). Typical value = 0,12." },
1791 AttrDef { id: "ExcAVR2.se1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Saturation factor at E1 (S[E1]). Typical value = 0.1." },
1792 AttrDef { id: "ExcAVR2.se2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Saturation factor at E2 (S[E2]). Typical value = 0,03." },
1793 AttrDef { id: "ExcAVR2.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "AVR time constant (TA) (>= 0). Typical value = 0,02." },
1794 AttrDef { id: "ExcAVR2.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "AVR time constant (TB) (>= 0). Typical value = 0." },
1795 AttrDef { id: "ExcAVR2.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant (TE) (>= 0). Typical value = 1." },
1796 AttrDef { id: "ExcAVR2.tf1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rate feedback time constant (TF1) (>= 0). Typical value = 1." },
1797 AttrDef { id: "ExcAVR2.tf2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rate feedback time constant (TF2) (>= 0). Typical value = 1." },
1798 AttrDef { id: "ExcAVR2.vrmn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum AVR output (VRMN). Typical value = -6." },
1799 AttrDef { id: "ExcAVR2.vrmx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum AVR output (VRMX). Typical value = 7." },
1800 ],
1801 },
1802 ClassDef {
1803 ns: "http://iec.ch/TC57/CIM100#",
1804 local: "ExcAVR3",
1805 qualified: "ExcAVR3",
1806 super_class: Some(161),
1807 concrete: true,
1808 origins: &["DY"],
1809 comment: "Italian excitation system. It represents an exciter dynamo and electric regulator.",
1810 attrs: &[
1811 AttrDef { id: "ExcAVR3.e1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field voltage value 1 (E1). Typical value = 4,18." },
1812 AttrDef { id: "ExcAVR3.e2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field voltage value 2 (E2). Typical value = 3,14." },
1813 AttrDef { id: "ExcAVR3.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "AVR gain (KA). Typical value = 100." },
1814 AttrDef { id: "ExcAVR3.se1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Saturation factor at E1 (S[E1]). Typical value = 0,1." },
1815 AttrDef { id: "ExcAVR3.se2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Saturation factor at E2 (S[E2]). Typical value = 0,03." },
1816 AttrDef { id: "ExcAVR3.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "AVR time constant (T1) (>= 0). Typical value = 20." },
1817 AttrDef { id: "ExcAVR3.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "AVR time constant (T2) (>= 0). Typical value = 1,6." },
1818 AttrDef { id: "ExcAVR3.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "AVR time constant (T3) (>= 0). Typical value = 0,66." },
1819 AttrDef { id: "ExcAVR3.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "AVR time constant (T4) (>= 0). Typical value = 0,07." },
1820 AttrDef { id: "ExcAVR3.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant (TE) (>= 0). Typical value = 1." },
1821 AttrDef { id: "ExcAVR3.vrmn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum AVR output (VRMN). Typical value = -7,5." },
1822 AttrDef { id: "ExcAVR3.vrmx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum AVR output (VRMX). Typical value = 7,5." },
1823 ],
1824 },
1825 ClassDef {
1826 ns: "http://iec.ch/TC57/CIM100#",
1827 local: "ExcAVR4",
1828 qualified: "ExcAVR4",
1829 super_class: Some(161),
1830 concrete: true,
1831 origins: &["DY"],
1832 comment: "Italian excitation system. It represents a static exciter and electric voltage regulator.",
1833 attrs: &[
1834 AttrDef { id: "ExcAVR4.imul", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "AVR output voltage dependency selector (IMUL). true = selector is connected false = selector is not connected. Typical value = true." },
1835 AttrDef { id: "ExcAVR4.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "AVR gain (KA). Typical value = 300." },
1836 AttrDef { id: "ExcAVR4.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter gain (KE). Typical value = 1." },
1837 AttrDef { id: "ExcAVR4.kif", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter internal reactance (KIF). Typical value = 0." },
1838 AttrDef { id: "ExcAVR4.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "AVR time constant (T1) (>= 0). Typical value = 4,8." },
1839 AttrDef { id: "ExcAVR4.t1if", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter current feedback time constant (T1IF) (>= 0). Typical value = 60." },
1840 AttrDef { id: "ExcAVR4.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "AVR time constant (T2) (>= 0). Typical value = 1,5." },
1841 AttrDef { id: "ExcAVR4.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "AVR time constant (T3) (>= 0). Typical value = 0." },
1842 AttrDef { id: "ExcAVR4.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "AVR time constant (T4) (>= 0). Typical value = 0." },
1843 AttrDef { id: "ExcAVR4.tif", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter current feedback time constant (TIF) (>= 0). Typical value = 0." },
1844 AttrDef { id: "ExcAVR4.vfmn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum exciter output (VFMN). Typical value = 0." },
1845 AttrDef { id: "ExcAVR4.vfmx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum exciter output (VFMX). Typical value = 5." },
1846 AttrDef { id: "ExcAVR4.vrmn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum AVR output (VRMN). Typical value = 0." },
1847 AttrDef { id: "ExcAVR4.vrmx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum AVR output (VRMX). Typical value = 5." },
1848 ],
1849 },
1850 ClassDef {
1851 ns: "http://iec.ch/TC57/CIM100#",
1852 local: "ExcAVR5",
1853 qualified: "ExcAVR5",
1854 super_class: Some(161),
1855 concrete: true,
1856 origins: &["DY"],
1857 comment: "Manual excitation control with field circuit resistance. This model can be used as a very simple representation of manual voltage control.",
1858 attrs: &[
1859 AttrDef { id: "ExcAVR5.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (Ka)." },
1860 AttrDef { id: "ExcAVR5.rex", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Effective output resistance (Rex). Rex represents the effective output resistance seen by the excitation system." },
1861 AttrDef { id: "ExcAVR5.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Ta) (>= 0)." },
1862 ],
1863 },
1864 ClassDef {
1865 ns: "http://iec.ch/TC57/CIM100#",
1866 local: "ExcAVR7",
1867 qualified: "ExcAVR7",
1868 super_class: Some(161),
1869 concrete: true,
1870 origins: &["DY"],
1871 comment: "IVO excitation system.",
1872 attrs: &[
1873 AttrDef { id: "ExcAVR7.a1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead coefficient (A1). Typical value = 0,5." },
1874 AttrDef { id: "ExcAVR7.a2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag coefficient (A2). Typical value = 0,5." },
1875 AttrDef { id: "ExcAVR7.a3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead coefficient (A3). Typical value = 0,5." },
1876 AttrDef { id: "ExcAVR7.a4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag coefficient (A4). Typical value = 0,5." },
1877 AttrDef { id: "ExcAVR7.a5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead coefficient (A5). Typical value = 0,5." },
1878 AttrDef { id: "ExcAVR7.a6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag coefficient (A6). Typical value = 0,5." },
1879 AttrDef { id: "ExcAVR7.k1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (K1). Typical value = 1." },
1880 AttrDef { id: "ExcAVR7.k3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (K3). Typical value = 3." },
1881 AttrDef { id: "ExcAVR7.k5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (K5). Typical value = 1." },
1882 AttrDef { id: "ExcAVR7.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead time constant (T1) (>= 0). Typical value = 0,05." },
1883 AttrDef { id: "ExcAVR7.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant (T2) (>= 0). Typical value = 0,1." },
1884 AttrDef { id: "ExcAVR7.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead time constant (T3) (>= 0). Typical value = 0,1." },
1885 AttrDef { id: "ExcAVR7.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant (T4) (>= 0). Typical value = 0,1." },
1886 AttrDef { id: "ExcAVR7.t5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead time constant (T5) (>= 0). Typical value = 0,1." },
1887 AttrDef { id: "ExcAVR7.t6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant (T6) (>= 0). Typical value = 0,1." },
1888 AttrDef { id: "ExcAVR7.vmax1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead-lag maximum limit (Vmax1) (> ExcAVR7.vmin1). Typical value = 5." },
1889 AttrDef { id: "ExcAVR7.vmax3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead-lag maximum limit (Vmax3) (> ExcAVR7.vmin3). Typical value = 5." },
1890 AttrDef { id: "ExcAVR7.vmax5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead-lag maximum limit (Vmax5) (> ExcAVR7.vmin5). Typical value = 5." },
1891 AttrDef { id: "ExcAVR7.vmin1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead-lag minimum limit (Vmin1) (< ExcAVR7.vmax1). Typical value = -5." },
1892 AttrDef { id: "ExcAVR7.vmin3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead-lag minimum limit (Vmin3) (< ExcAVR7.vmax3). Typical value = -5." },
1893 AttrDef { id: "ExcAVR7.vmin5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead-lag minimum limit (Vmin5) (< ExcAVR7.vmax5). Typical value = -2." },
1894 ],
1895 },
1896 ClassDef {
1897 ns: "http://iec.ch/TC57/CIM100#",
1898 local: "ExcBBC",
1899 qualified: "ExcBBC",
1900 super_class: Some(161),
1901 concrete: true,
1902 origins: &["DY"],
1903 comment: "Transformer fed static excitation system (static with ABB regulator). This model represents a static excitation system in which a gated thyristor bridge fed by a transformer at the main generator terminals feeds the main generator directly.",
1904 attrs: &[
1905 AttrDef { id: "ExcBBC.efdmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum open circuit exciter voltage (Efdmax) (> ExcBBC.efdmin). Typical value = 5." },
1906 AttrDef { id: "ExcBBC.efdmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum open circuit exciter voltage (Efdmin) (< ExcBBC.efdmax). Typical value = -5." },
1907 AttrDef { id: "ExcBBC.k", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Steady state gain (K) (not = 0). Typical value = 300." },
1908 AttrDef { id: "ExcBBC.switch", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Supplementary signal routing selector (switch). true = Vs connected to 3rd summing point false = Vs connected to 1st summing point (see diagram). Typical value = false." },
1909 AttrDef { id: "ExcBBC.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Controller time constant (T1) (>= 0). Typical value = 6." },
1910 AttrDef { id: "ExcBBC.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Controller time constant (T2) (>= 0). Typical value = 1." },
1911 AttrDef { id: "ExcBBC.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T3) (>= 0). If = 0, block is bypassed. Typical value = 0,05." },
1912 AttrDef { id: "ExcBBC.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T4) (>= 0). If = 0, block is bypassed. Typical value = 0,01." },
1913 AttrDef { id: "ExcBBC.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum control element output (Vrmax) (> ExcBBC.vrmin). Typical value = 5." },
1914 AttrDef { id: "ExcBBC.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum control element output (Vrmin) (< ExcBBC.vrmax). Typical value = -5." },
1915 AttrDef { id: "ExcBBC.xe", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Effective excitation transformer reactance (Xe) (>= 0). Xe models the regulation of the transformer/rectifier unit. Typical value = 0,05." },
1916 ],
1917 },
1918 ClassDef {
1919 ns: "http://iec.ch/TC57/CIM100#",
1920 local: "ExcCZ",
1921 qualified: "ExcCZ",
1922 super_class: Some(161),
1923 concrete: true,
1924 origins: &["DY"],
1925 comment: "Czech proportion/integral exciter.",
1926 attrs: &[
1927 AttrDef { id: "ExcCZ.efdmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter output maximum limit (Efdmax) (> ExcCZ.efdmin)." },
1928 AttrDef { id: "ExcCZ.efdmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter output minimum limit (Efdmin) (< ExcCZ.efdmax)." },
1929 AttrDef { id: "ExcCZ.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Regulator gain (Ka)." },
1930 AttrDef { id: "ExcCZ.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (Ke)." },
1931 AttrDef { id: "ExcCZ.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Regulator proportional gain (Kp)." },
1932 AttrDef { id: "ExcCZ.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Regulator time constant (Ta) (>= 0)." },
1933 AttrDef { id: "ExcCZ.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Regulator integral time constant (Tc) (>= 0)." },
1934 AttrDef { id: "ExcCZ.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (Te) (>= 0)." },
1935 AttrDef { id: "ExcCZ.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator maximum limit (Vrmax) (> ExcCZ.vrmin)." },
1936 AttrDef { id: "ExcCZ.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator minimum limit (Vrmin) (< ExcCZ.vrmax)." },
1937 ],
1938 },
1939 ClassDef {
1940 ns: "http://iec.ch/TC57/CIM100#",
1941 local: "ExcDC1A",
1942 qualified: "ExcDC1A",
1943 super_class: Some(161),
1944 concrete: true,
1945 origins: &["DY"],
1946 comment: "Modified IEEE DC1A direct current commutator exciter with speed input and without underexcitation limiters (UEL) inputs.",
1947 attrs: &[
1948 AttrDef { id: "ExcDC1A.efd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter voltage at which exciter saturation is defined (Efd1) (> 0). Typical value = 3,1." },
1949 AttrDef { id: "ExcDC1A.efd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter voltage at which exciter saturation is defined (Efd2) (> 0). Typical value = 2,3." },
1950 AttrDef { id: "ExcDC1A.efdmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage exciter output limiter (Efdmax) (> ExcDC1A.efdmin). Typical value = 99." },
1951 AttrDef { id: "ExcDC1A.efdmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage exciter output limiter (Efdmin) (< ExcDC1A.edfmax). Typical value = -99." },
1952 AttrDef { id: "ExcDC1A.exclim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "(exclim). IEEE standard is ambiguous about lower limit on exciter output. true = a lower limit of zero is applied to integrator output false = a lower limit of zero is not applied to integrator output. Typical value = true." },
1953 AttrDef { id: "ExcDC1A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (Ka) (> 0). Typical value = 46." },
1954 AttrDef { id: "ExcDC1A.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (Ke). Typical value = 0." },
1955 AttrDef { id: "ExcDC1A.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gain (Kf) (>= 0). Typical value = 0,1." },
1956 AttrDef { id: "ExcDC1A.ks", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient to allow different usage of the model-speed coefficient (Ks). Typical value = 0." },
1957 AttrDef { id: "ExcDC1A.seefd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Efd1 (Se[Eefd1]) (>= 0). Typical value = 0,33." },
1958 AttrDef { id: "ExcDC1A.seefd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Efd2 (Se[Eefd2]) (>= 0). Typical value = 0,1." },
1959 AttrDef { id: "ExcDC1A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Ta) (> 0). Typical value = 0,06." },
1960 AttrDef { id: "ExcDC1A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tb) (>= 0). Typical value = 0." },
1961 AttrDef { id: "ExcDC1A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tc) (>= 0). Typical value = 0." },
1962 AttrDef { id: "ExcDC1A.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (Te) (> 0). Typical value = 0,46." },
1963 AttrDef { id: "ExcDC1A.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (Tf) (> 0). Typical value = 1." },
1964 AttrDef { id: "ExcDC1A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (Vrmax) (> ExcDC1A.vrmin). Typical value = 1." },
1965 AttrDef { id: "ExcDC1A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (Vrmin) (< 0 and < ExcDC1A.vrmax). Typical value = -0,9." },
1966 ],
1967 },
1968 ClassDef {
1969 ns: "http://iec.ch/TC57/CIM100#",
1970 local: "ExcDC2A",
1971 qualified: "ExcDC2A",
1972 super_class: Some(161),
1973 concrete: true,
1974 origins: &["DY"],
1975 comment: "Modified IEEE DC2A direct current commutator exciter with speed input, one more leg block in feedback loop and without underexcitation limiters (UEL) inputs. DC type 2 excitation system model with added speed multiplier, added lead-lag, and voltage-dependent limits.",
1976 attrs: &[
1977 AttrDef { id: "ExcDC2A.efd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter voltage at which exciter saturation is defined (Efd1) (> 0). Typical value = 3,05." },
1978 AttrDef { id: "ExcDC2A.efd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter voltage at which exciter saturation is defined (Efd2) (> 0). Typical value = 2,29." },
1979 AttrDef { id: "ExcDC2A.exclim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "(exclim). IEEE standard is ambiguous about lower limit on exciter output. true = a lower limit of zero is applied to integrator output false = a lower limit of zero is not applied to integrator output. Typical value = true." },
1980 AttrDef { id: "ExcDC2A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (Ka) (> 0). Typical value = 300." },
1981 AttrDef { id: "ExcDC2A.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (Ke). If Ke is entered as zero, the model calculates an effective value of Ke such that the initial condition value of Vr is zero. The zero value of Ke is not changed. If Ke is entered as non-zero, its value is used directly, without change. Typical value = 1." },
1982 AttrDef { id: "ExcDC2A.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gain (Kf) (>= 0). Typical value = 0,1." },
1983 AttrDef { id: "ExcDC2A.ks", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient to allow different usage of the model-speed coefficient (Ks). Typical value = 0." },
1984 AttrDef { id: "ExcDC2A.seefd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Efd1 (Se[Efd1]) (>= 0). Typical value = 0,279." },
1985 AttrDef { id: "ExcDC2A.seefd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Efd2 (Se[Efd2]) (>= 0). Typical value = 0,117." },
1986 AttrDef { id: "ExcDC2A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Ta) (> 0). Typical value = 0,01." },
1987 AttrDef { id: "ExcDC2A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tb) (>= 0). Typical value = 0." },
1988 AttrDef { id: "ExcDC2A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tc) (>= 0). Typical value = 0." },
1989 AttrDef { id: "ExcDC2A.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (Te) (> 0). Typical value = 1,33." },
1990 AttrDef { id: "ExcDC2A.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (Tf) (> 0). Typical value = 0,675." },
1991 AttrDef { id: "ExcDC2A.tf1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (Tf1) (>= 0). Typical value = 0." },
1992 AttrDef { id: "ExcDC2A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (Vrmax) (> ExcDC2A.vrmin). Typical value = 4,95." },
1993 AttrDef { id: "ExcDC2A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (Vrmin) (< 0 and < ExcDC2A.vrmax). Typical value = -4,9." },
1994 AttrDef { id: "ExcDC2A.vtlim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "(Vtlim). true = limiter at the block (Ka / [1 + sTa]) is dependent on Vt false = limiter at the block is not dependent on Vt. Typical value = true." },
1995 ],
1996 },
1997 ClassDef {
1998 ns: "http://iec.ch/TC57/CIM100#",
1999 local: "ExcDC3A",
2000 qualified: "ExcDC3A",
2001 super_class: Some(161),
2002 concrete: true,
2003 origins: &["DY"],
2004 comment: "Modified IEEE DC3A direct current commutator exciter with speed input, and deadband. DC old type 4.",
2005 attrs: &[
2006 AttrDef { id: "ExcDC3A.efd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter voltage at which exciter saturation is defined (Efd1) (> 0). Typical value = 2,6." },
2007 AttrDef { id: "ExcDC3A.efd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter voltage at which exciter saturation is defined (Efd2) (> 0). Typical value = 3,45." },
2008 AttrDef { id: "ExcDC3A.efdlim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "(Efdlim). true = exciter output limiter is active false = exciter output limiter not active. Typical value = true." },
2009 AttrDef { id: "ExcDC3A.efdmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage exciter output limiter (Efdmax) (> ExcDC3A.efdmin). Typical value = 99." },
2010 AttrDef { id: "ExcDC3A.efdmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage exciter output limiter (Efdmin) (< ExcDC3A.efdmax). Typical value = -99." },
2011 AttrDef { id: "ExcDC3A.exclim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "(exclim). IEEE standard is ambiguous about lower limit on exciter output. true = a lower limit of zero is applied to integrator output false = a lower limit of zero not applied to integrator output. Typical value = true." },
2012 AttrDef { id: "ExcDC3A.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (Ke). Typical value = 1." },
2013 AttrDef { id: "ExcDC3A.kr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Deadband (Kr). Typical value = 0." },
2014 AttrDef { id: "ExcDC3A.ks", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient to allow different usage of the model-speed coefficient (Ks). Typical value = 0." },
2015 AttrDef { id: "ExcDC3A.kv", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fast raise/lower contact setting (Kv) (> 0). Typical value = 0,05." },
2016 AttrDef { id: "ExcDC3A.seefd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Efd1 (Se[Efd1]) (>= 0). Typical value = 0,1." },
2017 AttrDef { id: "ExcDC3A.seefd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Efd2 (Se[Efd2]) (>= 0). Typical value = 0,35." },
2018 AttrDef { id: "ExcDC3A.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (Te) (> 0). Typical value = 1,83." },
2019 AttrDef { id: "ExcDC3A.trh", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rheostat travel time (Trh) (> 0). Typical value = 20." },
2020 AttrDef { id: "ExcDC3A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (Vrmax) (> 0). Typical value = 5." },
2021 AttrDef { id: "ExcDC3A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (Vrmin) (<= 0). Typical value = 0." },
2022 ],
2023 },
2024 ClassDef {
2025 ns: "http://iec.ch/TC57/CIM100#",
2026 local: "ExcDC3A1",
2027 qualified: "ExcDC3A1",
2028 super_class: Some(161),
2029 concrete: true,
2030 origins: &["DY"],
2031 comment: "Modified old IEEE type 3 excitation system.",
2032 attrs: &[
2033 AttrDef { id: "ExcDC3A1.exclim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "(exclim). true = lower limit of zero is applied to integrator output false = lower limit of zero not applied to integrator output. Typical value = true." },
2034 AttrDef { id: "ExcDC3A1.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (Ka) (> 0). Typical value = 300." },
2035 AttrDef { id: "ExcDC3A1.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (Ke). Typical value = 1." },
2036 AttrDef { id: "ExcDC3A1.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gain (Kf) (>= 0). Typical value = 0,1." },
2037 AttrDef { id: "ExcDC3A1.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential circuit gain coefficient (Ki) (>= 0). Typical value = 4,83." },
2038 AttrDef { id: "ExcDC3A1.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential circuit gain coefficient (Kp) (>= 0). Typical value = 4,37." },
2039 AttrDef { id: "ExcDC3A1.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Ta) (> 0). Typical value = 0,01." },
2040 AttrDef { id: "ExcDC3A1.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (Te) (> 0). Typical value = 1,83." },
2041 AttrDef { id: "ExcDC3A1.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (Tf) (>= 0). Typical value = 0,675." },
2042 AttrDef { id: "ExcDC3A1.vb1max", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Available exciter voltage limiter (Vb1max) (> 0). Typical value = 11,63." },
2043 AttrDef { id: "ExcDC3A1.vblim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Vb limiter indicator. true = exciter Vbmax limiter is active false = Vb1max is active. Typical value = true." },
2044 AttrDef { id: "ExcDC3A1.vbmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Available exciter voltage limiter (Vbmax) (> 0). Typical value = 11,63." },
2045 AttrDef { id: "ExcDC3A1.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (Vrmax) (> ExcDC3A1.vrmin). Typical value = 5." },
2046 AttrDef { id: "ExcDC3A1.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (Vrmin) (< 0 and < ExcDC3A1.vrmax). Typical value = 0." },
2047 ],
2048 },
2049 ClassDef {
2050 ns: "http://iec.ch/TC57/CIM100#",
2051 local: "ExcELIN1",
2052 qualified: "ExcELIN1",
2053 super_class: Some(161),
2054 concrete: true,
2055 origins: &["DY"],
2056 comment: "Static PI transformer fed excitation system ELIN (VATECH) - simplified model. This model represents an all-static excitation system. A PI voltage controller establishes a desired field current set point for a proportional current controller. The integrator of the PI controller has a follow-up input to match its signal to the present field current. A power system stabilizer with power input is included in the model.",
2057 attrs: &[
2058 AttrDef { id: "ExcELIN1.dpnf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Controller follow up deadband (Dpnf). Typical value = 0." },
2059 AttrDef { id: "ExcELIN1.efmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum open circuit excitation voltage (Efmax) (> ExcELIN1.efmin). Typical value = 5." },
2060 AttrDef { id: "ExcELIN1.efmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum open circuit excitation voltage (Efmin) (< ExcELIN1.efmax). Typical value = -5." },
2061 AttrDef { id: "ExcELIN1.ks1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer gain 1 (Ks1). Typical value = 0." },
2062 AttrDef { id: "ExcELIN1.ks2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer gain 2 (Ks2). Typical value = 0." },
2063 AttrDef { id: "ExcELIN1.smax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer limit output (smax). Typical value = 0,1." },
2064 AttrDef { id: "ExcELIN1.tfi", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Current transducer time constant (Tfi) (>= 0). Typical value = 0." },
2065 AttrDef { id: "ExcELIN1.tnu", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Controller reset time constant (Tnu) (>= 0). Typical value = 2." },
2066 AttrDef { id: "ExcELIN1.ts1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer phase lag time constant (Ts1) (>= 0). Typical value = 1." },
2067 AttrDef { id: "ExcELIN1.ts2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer filter time constant (Ts2) (>= 0). Typical value = 1." },
2068 AttrDef { id: "ExcELIN1.tsw", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer parameters (Tsw) (>= 0). Typical value = 3." },
2069 AttrDef { id: "ExcELIN1.vpi", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Current controller gain (Vpi). Typical value = 12,45." },
2070 AttrDef { id: "ExcELIN1.vpnf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Controller follow up gain (Vpnf). Typical value = 2." },
2071 AttrDef { id: "ExcELIN1.vpu", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage controller proportional gain (Vpu). Typical value = 34,5." },
2072 AttrDef { id: "ExcELIN1.xe", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation transformer effective reactance (Xe) (>= 0). Xe represents the regulation of the transformer/rectifier unit. Typical value = 0,06." },
2073 ],
2074 },
2075 ClassDef {
2076 ns: "http://iec.ch/TC57/CIM100#",
2077 local: "ExcELIN2",
2078 qualified: "ExcELIN2",
2079 super_class: Some(161),
2080 concrete: true,
2081 origins: &["DY"],
2082 comment: "Detailed excitation system ELIN (VATECH). This model represents an all-static excitation system. A PI voltage controller establishes a desired field current set point for a proportional current controller. The integrator of the PI controller has a follow-up input to match its signal to the present field current. Power system stabilizer models used in conjunction with this excitation system model: PssELIN2, PssIEEE2B, Pss2B.",
2083 attrs: &[
2084 AttrDef { id: "ExcELIN2.efdbas", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (Efdbas). Typical value = 0,1." },
2085 AttrDef { id: "ExcELIN2.iefmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter (Iefmax) (> ExcELIN2.iefmin). Typical value = 1." },
2086 AttrDef { id: "ExcELIN2.iefmax2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum open circuit excitation voltage (Iefmax2). Typical value = -5." },
2087 AttrDef { id: "ExcELIN2.iefmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter (Iefmin) (< ExcELIN2.iefmax). Typical value = 1." },
2088 AttrDef { id: "ExcELIN2.k1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator input gain (K1). Typical value = 0." },
2089 AttrDef { id: "ExcELIN2.k1ec", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator input limit (K1ec). Typical value = 2." },
2090 AttrDef { id: "ExcELIN2.k2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (K2). Typical value = 5." },
2091 AttrDef { id: "ExcELIN2.k3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (K3). Typical value = 0,1." },
2092 AttrDef { id: "ExcELIN2.k4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (K4). Typical value = 0." },
2093 AttrDef { id: "ExcELIN2.kd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage controller derivative gain (Kd1). Typical value = 34,5." },
2094 AttrDef { id: "ExcELIN2.ke2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (Ke2). Typical value = 0,1." },
2095 AttrDef { id: "ExcELIN2.ketb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (Ketb). Typical value = 0,06." },
2096 AttrDef { id: "ExcELIN2.pid1max", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Controller follow up gain (PID1max). Typical value = 2." },
2097 AttrDef { id: "ExcELIN2.seve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Ve1, back of commutating reactance (Se[Ve1]) (>= 0). Typical value = 0." },
2098 AttrDef { id: "ExcELIN2.seve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, Ve2, back of commutating reactance (Se[Ve2]) (>= 0). Typical value = 1." },
2099 AttrDef { id: "ExcELIN2.tb1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage controller derivative washout time constant (Tb1) (>= 0). Typical value = 12,45." },
2100 AttrDef { id: "ExcELIN2.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Te) (>= 0). Typical value = 0." },
2101 AttrDef { id: "ExcELIN2.te2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time Constant (Te2) (>= 0). Typical value = 1." },
2102 AttrDef { id: "ExcELIN2.ti1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Controller follow up deadband (Ti1). Typical value = 0." },
2103 AttrDef { id: "ExcELIN2.ti3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Ti3) (>= 0). Typical value = 3." },
2104 AttrDef { id: "ExcELIN2.ti4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Ti4) (>= 0). Typical value = 0." },
2105 AttrDef { id: "ExcELIN2.tr4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Tr4) (>= 0). Typical value = 1." },
2106 AttrDef { id: "ExcELIN2.upmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter (Upmax) (> ExcELIN2.upmin). Typical value = 3." },
2107 AttrDef { id: "ExcELIN2.upmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter (Upmin) (< ExcELIN2.upmax). Typical value = 0." },
2108 AttrDef { id: "ExcELIN2.ve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (Ve1) (> 0). Typical value = 3." },
2109 AttrDef { id: "ExcELIN2.ve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (Ve2) (> 0). Typical value = 0." },
2110 AttrDef { id: "ExcELIN2.xp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation transformer effective reactance (Xp). Typical value = 1." },
2111 ],
2112 },
2113 ClassDef {
2114 ns: "http://iec.ch/TC57/CIM100#",
2115 local: "ExcHU",
2116 qualified: "ExcHU",
2117 super_class: Some(161),
2118 concrete: true,
2119 origins: &["DY"],
2120 comment: "Hungarian excitation system, with built-in voltage transducer.",
2121 attrs: &[
2122 AttrDef { id: "ExcHU.ae", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Major loop PI tag gain factor (Ae). Typical value = 3." },
2123 AttrDef { id: "ExcHU.ai", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minor loop PI tag gain factor (Ai). Typical value = 22." },
2124 AttrDef { id: "ExcHU.atr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "AVR constant (Atr). Typical value = 2,19." },
2125 AttrDef { id: "ExcHU.emax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field voltage control signal upper limit on AVR base (Emax) (> ExcHU.emin). Typical value = 0,996." },
2126 AttrDef { id: "ExcHU.emin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field voltage control signal lower limit on AVR base (Emin) (< ExcHU.emax). Typical value = -0,866." },
2127 AttrDef { id: "ExcHU.imax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Major loop PI tag output signal upper limit (Imax) (> ExcHU.imin). Typical value = 2,19." },
2128 AttrDef { id: "ExcHU.imin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Major loop PI tag output signal lower limit (Imin) (< ExcHU.imax). Typical value = 0,1." },
2129 AttrDef { id: "ExcHU.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage base conversion constant (Ke). Typical value = 4,666." },
2130 AttrDef { id: "ExcHU.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Current base conversion constant (Ki). Typical value = 0,21428." },
2131 AttrDef { id: "ExcHU.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Major loop PI tag integration time constant (Te) (>= 0). Typical value = 0,154." },
2132 AttrDef { id: "ExcHU.ti", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minor loop PI control tag integration time constant (Ti) (>= 0). Typical value = 0,01333." },
2133 AttrDef { id: "ExcHU.tr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter time constant (Tr) (>= 0). If a voltage compensator is used in conjunction with this excitation system model, Tr should be set to 0. Typical value = 0,01." },
2134 ],
2135 },
2136 ClassDef {
2137 ns: "http://iec.ch/TC57/CIM100#",
2138 local: "ExcIEEEAC1A",
2139 qualified: "ExcIEEEAC1A",
2140 super_class: Some(161),
2141 concrete: true,
2142 origins: &["DY"],
2143 comment: "IEEE 421.5-2005 type AC1A model. The model represents the field-controlled alternator-rectifier excitation systems designated type AC1A. These excitation systems consist of an alternator main exciter with non-controlled rectifiers. Reference: IEEE 421.5-2005, 6.1.",
2144 attrs: &[
2145 AttrDef { id: "ExcIEEEAC1A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (KA) (> 0). Typical value = 400." },
2146 AttrDef { id: "ExcIEEEAC1A.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (KC) (>= 0). Typical value = 0,2." },
2147 AttrDef { id: "ExcIEEEAC1A.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Demagnetizing factor, a function of exciter alternator reactances (KD) (>= 0). Typical value = 0,38." },
2148 AttrDef { id: "ExcIEEEAC1A.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (KE). Typical value = 1." },
2149 AttrDef { id: "ExcIEEEAC1A.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gains (KF) (>= 0). Typical value = 0,03." },
2150 AttrDef { id: "ExcIEEEAC1A.seve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, VE1, back of commutating reactance (SE[VE1]) (>= 0). Typical value = 0,1." },
2151 AttrDef { id: "ExcIEEEAC1A.seve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, VE2, back of commutating reactance (SE[VE2]) (>= 0). Typical value = 0,03." },
2152 AttrDef { id: "ExcIEEEAC1A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TA) (> 0). Typical value = 0,02." },
2153 AttrDef { id: "ExcIEEEAC1A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TB) (>= 0). Typical value = 0." },
2154 AttrDef { id: "ExcIEEEAC1A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TC) (>= 0). Typical value = 0." },
2155 AttrDef { id: "ExcIEEEAC1A.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (TE) (> 0). Typical value = 0,8." },
2156 AttrDef { id: "ExcIEEEAC1A.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (TF) (> 0). Typical value = 1." },
2157 AttrDef { id: "ExcIEEEAC1A.vamax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VAMAX) (> 0). Typical value = 14,5." },
2158 AttrDef { id: "ExcIEEEAC1A.vamin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VAMIN) (< 0). Typical value = -14,5." },
2159 AttrDef { id: "ExcIEEEAC1A.ve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (VE1) (> 0). Typical value = 4,18." },
2160 AttrDef { id: "ExcIEEEAC1A.ve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (VE2) (> 0). Typical value = 3,14." },
2161 AttrDef { id: "ExcIEEEAC1A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator outputs (VRMAX) (> 0). Typical value = 6,03." },
2162 AttrDef { id: "ExcIEEEAC1A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator outputs (VRMIN) (< 0). Typical value = -5,43." },
2163 ],
2164 },
2165 ClassDef {
2166 ns: "http://iec.ch/TC57/CIM100#",
2167 local: "ExcIEEEAC2A",
2168 qualified: "ExcIEEEAC2A",
2169 super_class: Some(161),
2170 concrete: true,
2171 origins: &["DY"],
2172 comment: "IEEE 421.5-2005 type AC2A model. The model represents a high initial response field-controlled alternator-rectifier excitation system. The alternator main exciter is used with non-controlled rectifiers. The type AC2A model is similar to that of type AC1A except for the inclusion of exciter time constant compensation and exciter field current limiting elements. Reference: IEEE 421.5-2005, 6.2.",
2173 attrs: &[
2174 AttrDef { id: "ExcIEEEAC2A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (KA) (> 0). Typical value = 400." },
2175 AttrDef { id: "ExcIEEEAC2A.kb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Second stage regulator gain (KB) (> 0). Typical value = 25." },
2176 AttrDef { id: "ExcIEEEAC2A.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (KC) (>= 0). Typical value = 0,28." },
2177 AttrDef { id: "ExcIEEEAC2A.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Demagnetizing factor, a function of exciter alternator reactances (KD) (>= 0). Typical value = 0,35." },
2178 AttrDef { id: "ExcIEEEAC2A.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (KE) (>= 0). Typical value = 1." },
2179 AttrDef { id: "ExcIEEEAC2A.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gains (KF) (>= 0). Typical value = 0,03." },
2180 AttrDef { id: "ExcIEEEAC2A.kh", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field current feedback gain (KH) (>= 0). Typical value = 1." },
2181 AttrDef { id: "ExcIEEEAC2A.seve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, VE1, back of commutating reactance (SE[VE1]) (>= 0). Typical value = 0,037." },
2182 AttrDef { id: "ExcIEEEAC2A.seve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, VE2, back of commutating reactance (SE[VE2]) (>= 0). Typical value = 0,012." },
2183 AttrDef { id: "ExcIEEEAC2A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TA) (> 0). Typical value = 0,02." },
2184 AttrDef { id: "ExcIEEEAC2A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TB) (>= 0). Typical value = 0." },
2185 AttrDef { id: "ExcIEEEAC2A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TC) (>= 0). Typical value = 0." },
2186 AttrDef { id: "ExcIEEEAC2A.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (TE) (> 0). Typical value = 0,6." },
2187 AttrDef { id: "ExcIEEEAC2A.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (TF) (> 0). Typical value = 1." },
2188 AttrDef { id: "ExcIEEEAC2A.vamax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VAMAX) (> 0). Typical value = 8." },
2189 AttrDef { id: "ExcIEEEAC2A.vamin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VAMIN) (< 0). Typical value = -8." },
2190 AttrDef { id: "ExcIEEEAC2A.ve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (VE1) (> 0). Typical value = 4,4." },
2191 AttrDef { id: "ExcIEEEAC2A.ve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (VE2) (> 0). Typical value = 3,3." },
2192 AttrDef { id: "ExcIEEEAC2A.vfemax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field current limit reference (VFEMAX) (> 0). Typical value = 4,4." },
2193 AttrDef { id: "ExcIEEEAC2A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator outputs (VRMAX) (> 0). Typical value = 105." },
2194 AttrDef { id: "ExcIEEEAC2A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator outputs (VRMIN) (< 0). Typical value = -95." },
2195 ],
2196 },
2197 ClassDef {
2198 ns: "http://iec.ch/TC57/CIM100#",
2199 local: "ExcIEEEAC3A",
2200 qualified: "ExcIEEEAC3A",
2201 super_class: Some(161),
2202 concrete: true,
2203 origins: &["DY"],
2204 comment: "IEEE 421.5-2005 type AC3A model. The model represents the field-controlled alternator-rectifier excitation systems designated type AC3A. These excitation systems include an alternator main exciter with non-controlled rectifiers. The exciter employs self-excitation, and the voltage regulator power is derived from the exciter output voltage. Therefore, this system has an additional nonlinearity, simulated by the use of a multiplier whose inputs are the voltage regulator command signal, Va, and the exciter output voltage, Efd, times KR. This model is applicable to excitation systems employing static voltage regulators. Reference: IEEE 421.5-2005, 6.3.",
2205 attrs: &[
2206 AttrDef { id: "ExcIEEEAC3A.efdn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Value of Efd at which feedback gain changes (EFDN) (> 0). Typical value = 2,36." },
2207 AttrDef { id: "ExcIEEEAC3A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (KA) (> 0). Typical value = 45,62." },
2208 AttrDef { id: "ExcIEEEAC3A.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (KC) (>= 0). Typical value = 0,104." },
2209 AttrDef { id: "ExcIEEEAC3A.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Demagnetizing factor, a function of exciter alternator reactances (KD) (>= 0). Typical value = 0,499." },
2210 AttrDef { id: "ExcIEEEAC3A.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (KE). Typical value = 1." },
2211 AttrDef { id: "ExcIEEEAC3A.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gains (KF) (>= 0). Typical value = 0,143." },
2212 AttrDef { id: "ExcIEEEAC3A.kn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gain (KN) (>= 0). Typical value = 0,05." },
2213 AttrDef { id: "ExcIEEEAC3A.kr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Constant associated with regulator and alternator field power supply (KR) (> 0). Typical value = 3,77." },
2214 AttrDef { id: "ExcIEEEAC3A.seve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, VE1, back of commutating reactance (SE[VE1]) (>= 0). Typical value = 1,143." },
2215 AttrDef { id: "ExcIEEEAC3A.seve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, VE2, back of commutating reactance (SE[VE2]) (>= 0). Typical value = 0,1." },
2216 AttrDef { id: "ExcIEEEAC3A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TA) (> 0). Typical value = 0,013." },
2217 AttrDef { id: "ExcIEEEAC3A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TB) (>= 0). Typical value = 0." },
2218 AttrDef { id: "ExcIEEEAC3A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TC) (>= 0). Typical value = 0." },
2219 AttrDef { id: "ExcIEEEAC3A.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (TE) (> 0). Typical value = 1,17." },
2220 AttrDef { id: "ExcIEEEAC3A.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (TF) (> 0). Typical value = 1." },
2221 AttrDef { id: "ExcIEEEAC3A.vamax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VAMAX) (> 0). Typical value = 1." },
2222 AttrDef { id: "ExcIEEEAC3A.vamin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VAMIN) (< 0). Typical value = -0,95." },
2223 AttrDef { id: "ExcIEEEAC3A.ve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (VE1) (> 0). Typical value = 6,24." },
2224 AttrDef { id: "ExcIEEEAC3A.ve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (VE2) (> 0). Typical value = 4,68." },
2225 AttrDef { id: "ExcIEEEAC3A.vemin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum exciter voltage output (VEMIN) (<= 0). Typical value = 0." },
2226 AttrDef { id: "ExcIEEEAC3A.vfemax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field current limit reference (VFEMAX) (>= 0). Typical value = 16." },
2227 ],
2228 },
2229 ClassDef {
2230 ns: "http://iec.ch/TC57/CIM100#",
2231 local: "ExcIEEEAC4A",
2232 qualified: "ExcIEEEAC4A",
2233 super_class: Some(161),
2234 concrete: true,
2235 origins: &["DY"],
2236 comment: "IEEE 421.5-2005 type AC4A model. The model represents type AC4A alternator-supplied controlled-rectifier excitation system which is quite different from the other types of AC systems. This high initial response excitation system utilizes a full thyristor bridge in the exciter output circuit. The voltage regulator controls the firing of the thyristor bridges. The exciter alternator uses an independent voltage regulator to control its output voltage to a constant value. These effects are not modelled; however, transient loading effects on the exciter alternator are included. Reference: IEEE 421.5-2005, 6.4.",
2237 attrs: &[
2238 AttrDef { id: "ExcIEEEAC4A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (KA) (> 0). Typical value = 200." },
2239 AttrDef { id: "ExcIEEEAC4A.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (KC) (>= 0). Typical value = 0." },
2240 AttrDef { id: "ExcIEEEAC4A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TA) (> 0). Typical value = 0,015." },
2241 AttrDef { id: "ExcIEEEAC4A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TB) (>= 0). Typical value = 10." },
2242 AttrDef { id: "ExcIEEEAC4A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TC) (>= 0). Typical value = 1." },
2243 AttrDef { id: "ExcIEEEAC4A.vimax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator input limit (VIMAX) (> 0). Typical value = 10." },
2244 AttrDef { id: "ExcIEEEAC4A.vimin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator input limit (VIMIN) (< 0). Typical value = -10." },
2245 AttrDef { id: "ExcIEEEAC4A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VRMAX) (> 0). Typical value = 5,64." },
2246 AttrDef { id: "ExcIEEEAC4A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VRMIN) (< 0). Typical value = -4,53." },
2247 ],
2248 },
2249 ClassDef {
2250 ns: "http://iec.ch/TC57/CIM100#",
2251 local: "ExcIEEEAC5A",
2252 qualified: "ExcIEEEAC5A",
2253 super_class: Some(161),
2254 concrete: true,
2255 origins: &["DY"],
2256 comment: "IEEE 421.5-2005 type AC5A model. The model represents a simplified model for brushless excitation systems. The regulator is supplied from a source, such as a permanent magnet generator, which is not affected by system disturbances. Unlike other AC models, this model uses loaded rather than open circuit exciter saturation data in the same way as it is used for the DC models. Because the model has been widely implemented by the industry, it is sometimes used to represent other types of systems when either detailed data for them are not available or simplified models are required. Reference: IEEE 421.5-2005, 6.5.",
2257 attrs: &[
2258 AttrDef { id: "ExcIEEEAC5A.efd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter voltage at which exciter saturation is defined (EFD1) (> 0). Typical value = 5,6." },
2259 AttrDef { id: "ExcIEEEAC5A.efd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter voltage at which exciter saturation is defined (EFD2) (> 0). Typical value = 4,2." },
2260 AttrDef { id: "ExcIEEEAC5A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (KA) (> 0). Typical value = 400." },
2261 AttrDef { id: "ExcIEEEAC5A.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (KE). Typical value = 1." },
2262 AttrDef { id: "ExcIEEEAC5A.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gains (KF) (>= 0). Typical value = 0,03." },
2263 AttrDef { id: "ExcIEEEAC5A.seefd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, EFD1 (SE[EFD1]) (>= 0). Typical value = 0,86." },
2264 AttrDef { id: "ExcIEEEAC5A.seefd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, EFD2 (SE[EFD2]) (>= 0). Typical value = 0,5." },
2265 AttrDef { id: "ExcIEEEAC5A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TA) (> 0). Typical value = 0,02." },
2266 AttrDef { id: "ExcIEEEAC5A.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (TE) (> 0). Typical value = 0,8." },
2267 AttrDef { id: "ExcIEEEAC5A.tf1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (TF1) (> 0). Typical value = 1." },
2268 AttrDef { id: "ExcIEEEAC5A.tf2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (TF2) (>= 0). Typical value = 1." },
2269 AttrDef { id: "ExcIEEEAC5A.tf3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (TF3) (>= 0). Typical value = 1." },
2270 AttrDef { id: "ExcIEEEAC5A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VRMAX) (> 0). Typical value = 7,3." },
2271 AttrDef { id: "ExcIEEEAC5A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VRMIN) (< 0). Typical value = -7,3." },
2272 ],
2273 },
2274 ClassDef {
2275 ns: "http://iec.ch/TC57/CIM100#",
2276 local: "ExcIEEEAC6A",
2277 qualified: "ExcIEEEAC6A",
2278 super_class: Some(161),
2279 concrete: true,
2280 origins: &["DY"],
2281 comment: "IEEE 421.5-2005 type AC6A model. The model represents field-controlled alternator-rectifier excitation systems with system-supplied electronic voltage regulators. The maximum output of the regulator, VR, is a function of terminal voltage, VT. The field current limiter included in the original model AC6A remains in the 2005 update. Reference: IEEE 421.5-2005, 6.6.",
2282 attrs: &[
2283 AttrDef { id: "ExcIEEEAC6A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (KA) (> 0). Typical value = 536." },
2284 AttrDef { id: "ExcIEEEAC6A.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (KC) (>= 0). Typical value = 0,173." },
2285 AttrDef { id: "ExcIEEEAC6A.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Demagnetizing factor, a function of exciter alternator reactances (KD) (>= 0). Typical value = 1,91." },
2286 AttrDef { id: "ExcIEEEAC6A.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (KE). Typical value = 1,6." },
2287 AttrDef { id: "ExcIEEEAC6A.kh", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field current limiter gain (KH) (>= 0). Typical value = 92." },
2288 AttrDef { id: "ExcIEEEAC6A.seve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, VE1, back of commutating reactance (SE[VE1]) (>= 0). Typical value = 0,214." },
2289 AttrDef { id: "ExcIEEEAC6A.seve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, VE2, back of commutating reactance (SE[VE2]) (>= 0). Typical value = 0,044." },
2290 AttrDef { id: "ExcIEEEAC6A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TA) (>= 0). Typical value = 0,086." },
2291 AttrDef { id: "ExcIEEEAC6A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TB) (>= 0). Typical value = 9." },
2292 AttrDef { id: "ExcIEEEAC6A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TC) (>= 0). Typical value = 3." },
2293 AttrDef { id: "ExcIEEEAC6A.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (TE) (> 0). Typical value = 1." },
2294 AttrDef { id: "ExcIEEEAC6A.th", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field current limiter time constant (TH) (> 0). Typical value = 0,08." },
2295 AttrDef { id: "ExcIEEEAC6A.tj", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field current limiter time constant (TJ) (>= 0). Typical value = 0,02." },
2296 AttrDef { id: "ExcIEEEAC6A.tk", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TK) (>= 0). Typical value = 0,18." },
2297 AttrDef { id: "ExcIEEEAC6A.vamax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VAMAX) (> 0). Typical value = 75." },
2298 AttrDef { id: "ExcIEEEAC6A.vamin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VAMIN) (< 0). Typical value = -75." },
2299 AttrDef { id: "ExcIEEEAC6A.ve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (VE1) (> 0). Typical value = 7,4." },
2300 AttrDef { id: "ExcIEEEAC6A.ve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (VE2) (> 0). Typical value = 5,55." },
2301 AttrDef { id: "ExcIEEEAC6A.vfelim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field current limit reference (VFELIM) (> 0). Typical value = 19." },
2302 AttrDef { id: "ExcIEEEAC6A.vhmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum field current limiter signal reference (VHMAX) (> 0). Typical value = 75." },
2303 AttrDef { id: "ExcIEEEAC6A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VRMAX) (> 0). Typical value = 44." },
2304 AttrDef { id: "ExcIEEEAC6A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VRMIN) (< 0). Typical value = -36." },
2305 ],
2306 },
2307 ClassDef {
2308 ns: "http://iec.ch/TC57/CIM100#",
2309 local: "ExcIEEEAC7B",
2310 qualified: "ExcIEEEAC7B",
2311 super_class: Some(161),
2312 concrete: true,
2313 origins: &["DY"],
2314 comment: "IEEE 421.5-2005 type AC7B model. The model represents excitation systems which consist of an AC alternator with either stationary or rotating rectifiers to produce the DC field requirements. It is an upgrade to earlier AC excitation systems, which replace only the controls but retain the AC alternator and diode rectifier bridge. Reference: IEEE 421.5-2005, 6.7. Note, however, that in IEEE 421.5-2005, the [1 / sTE] block is shown as [1 / (1 + sTE)], which is incorrect.",
2315 attrs: &[
2316 AttrDef { id: "ExcIEEEAC7B.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (KC) (>= 0). Typical value = 0,18." },
2317 AttrDef { id: "ExcIEEEAC7B.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Demagnetizing factor, a function of exciter alternator reactances (KD) (>= 0). Typical value = 0,02." },
2318 AttrDef { id: "ExcIEEEAC7B.kdr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator derivative gain (KDR) (>= 0). Typical value = 0." },
2319 AttrDef { id: "ExcIEEEAC7B.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (KE). Typical value = 1." },
2320 AttrDef { id: "ExcIEEEAC7B.kf1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gain (KF1) (>= 0). Typical value = 0,212." },
2321 AttrDef { id: "ExcIEEEAC7B.kf2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gain (KF2) (>= 0). Typical value = 0." },
2322 AttrDef { id: "ExcIEEEAC7B.kf3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gain (KF3) (>= 0). Typical value = 0." },
2323 AttrDef { id: "ExcIEEEAC7B.kia", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator integral gain (KIA) (>= 0). Typical value = 59,69." },
2324 AttrDef { id: "ExcIEEEAC7B.kir", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator integral gain (KIR) (>= 0). Typical value = 4,24." },
2325 AttrDef { id: "ExcIEEEAC7B.kl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field voltage lower limit parameter (KL). Typical value = 10." },
2326 AttrDef { id: "ExcIEEEAC7B.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential circuit gain coefficient (KP) (> 0). Typical value = 4,96." },
2327 AttrDef { id: "ExcIEEEAC7B.kpa", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator proportional gain (KPA) (> 0 if ExcIEEEAC7B.kia = 0). Typical value = 65,36." },
2328 AttrDef { id: "ExcIEEEAC7B.kpr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator proportional gain (KPR) (> 0 if ExcIEEEAC7B.kir = 0). Typical value = 4,24." },
2329 AttrDef { id: "ExcIEEEAC7B.seve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, VE1, back of commutating reactance (SE[VE1]) (>= 0). Typical value = 0,44." },
2330 AttrDef { id: "ExcIEEEAC7B.seve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, VE2, back of commutating reactance (SE[VE2]) (>= 0). Typical value = 0,075." },
2331 AttrDef { id: "ExcIEEEAC7B.tdr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant (TDR) (>= 0). Typical value = 0." },
2332 AttrDef { id: "ExcIEEEAC7B.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (TE) (> 0). Typical value = 1,1." },
2333 AttrDef { id: "ExcIEEEAC7B.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (TF) (> 0). Typical value = 1." },
2334 AttrDef { id: "ExcIEEEAC7B.vamax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VAMAX) (> 0). Typical value = 1." },
2335 AttrDef { id: "ExcIEEEAC7B.vamin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VAMIN) (< 0). Typical value = -0,95." },
2336 AttrDef { id: "ExcIEEEAC7B.ve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (VE1) (> 0). Typical value = 6,3." },
2337 AttrDef { id: "ExcIEEEAC7B.ve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (VE2) (> 0). Typical value = 3,02." },
2338 AttrDef { id: "ExcIEEEAC7B.vemin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum exciter voltage output (VEMIN) (<= 0). Typical value = 0." },
2339 AttrDef { id: "ExcIEEEAC7B.vfemax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field current limit reference (VFEMAX). Typical value = 6,9." },
2340 AttrDef { id: "ExcIEEEAC7B.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VRMAX) (> 0). Typical value = 5,79." },
2341 AttrDef { id: "ExcIEEEAC7B.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VRMIN) (< 0). Typical value = -5,79." },
2342 ],
2343 },
2344 ClassDef {
2345 ns: "http://iec.ch/TC57/CIM100#",
2346 local: "ExcIEEEAC8B",
2347 qualified: "ExcIEEEAC8B",
2348 super_class: Some(161),
2349 concrete: true,
2350 origins: &["DY"],
2351 comment: "IEEE 421.5-2005 type AC8B model. This model represents a PID voltage regulator with either a brushless exciter or DC exciter. The AVR in this model consists of PID control, with separate constants for the proportional (KPR), integral (KIR), and derivative (KDR) gains. The representation of the brushless exciter (TE, KE, SE, KC, KD) is similar to the model type AC2A. The type AC8B model can be used to represent static voltage regulators applied to brushless excitation systems. Digitally based voltage regulators feeding DC rotating main exciters can be represented with the AC type AC8B model with the parameters KC and KD set to 0. For thyristor power stages fed from the generator terminals, the limits VRMAX and VRMIN should be a function of terminal voltage: VT x VRMAX and VT x VRMIN. Reference: IEEE 421.5-2005, 6.8.",
2352 attrs: &[
2353 AttrDef { id: "ExcIEEEAC8B.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (KA) (> 0). Typical value = 1." },
2354 AttrDef { id: "ExcIEEEAC8B.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (KC) (>= 0). Typical value = 0,55." },
2355 AttrDef { id: "ExcIEEEAC8B.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Demagnetizing factor, a function of exciter alternator reactances (KD) (>= 0). Typical value = 1,1." },
2356 AttrDef { id: "ExcIEEEAC8B.kdr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator derivative gain (KDR) (>= 0). Typical value = 10." },
2357 AttrDef { id: "ExcIEEEAC8B.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (KE). Typical value = 1." },
2358 AttrDef { id: "ExcIEEEAC8B.kir", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator integral gain (KIR) (>= 0). Typical value = 5." },
2359 AttrDef { id: "ExcIEEEAC8B.kpr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator proportional gain (KPR) (> 0 if ExcIEEEAC8B.kir = 0). Typical value = 80." },
2360 AttrDef { id: "ExcIEEEAC8B.seve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, VE1, back of commutating reactance (SE[VE1]) (>= 0). Typical value = 0,3." },
2361 AttrDef { id: "ExcIEEEAC8B.seve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, VE2, back of commutating reactance (SE[VE2]) (>= 0). Typical value = 3." },
2362 AttrDef { id: "ExcIEEEAC8B.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TA) (>= 0). Typical value = 0." },
2363 AttrDef { id: "ExcIEEEAC8B.tdr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant (TDR) (> 0). Typical value = 0,1." },
2364 AttrDef { id: "ExcIEEEAC8B.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (TE) (> 0). Typical value = 1,2." },
2365 AttrDef { id: "ExcIEEEAC8B.ve1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (VE1) (> 0). Typical value = 6,5." },
2366 AttrDef { id: "ExcIEEEAC8B.ve2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter alternator output voltages back of commutating reactance at which saturation is defined (VE2) (> 0). Typical value = 9." },
2367 AttrDef { id: "ExcIEEEAC8B.vemin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum exciter voltage output (VEMIN) (<= 0). Typical value = 0." },
2368 AttrDef { id: "ExcIEEEAC8B.vfemax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field current limit reference (VFEMAX). Typical value = 6." },
2369 AttrDef { id: "ExcIEEEAC8B.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VRMAX) (> 0). Typical value = 35." },
2370 AttrDef { id: "ExcIEEEAC8B.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VRMIN) (<= 0). Typical value = 0." },
2371 ],
2372 },
2373 ClassDef {
2374 ns: "http://iec.ch/TC57/CIM100#",
2375 local: "ExcIEEEDC1A",
2376 qualified: "ExcIEEEDC1A",
2377 super_class: Some(161),
2378 concrete: true,
2379 origins: &["DY"],
2380 comment: "IEEE 421.5-2005 type DC1A model. This model represents field-controlled DC commutator exciters with continuously acting voltage regulators (especially the direct-acting rheostatic, rotating amplifier, and magnetic amplifier types). Because this model has been widely implemented by the industry, it is sometimes used to represent other types of systems when detailed data for them are not available or when a simplified model is required. Reference: IEEE 421.5-2005, 5.1.",
2381 attrs: &[
2382 AttrDef { id: "ExcIEEEDC1A.efd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter voltage at which exciter saturation is defined (EFD1) (> 0). Typical value = 3,1." },
2383 AttrDef { id: "ExcIEEEDC1A.efd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter voltage at which exciter saturation is defined (EFD2) (> 0). Typical value = 2,3." },
2384 AttrDef { id: "ExcIEEEDC1A.exclim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "(exclim). IEEE standard is ambiguous about lower limit on exciter output. true = a lower limit of zero is applied to integrator output false = a lower limit of zero is not applied to integrator output. Typical value = true." },
2385 AttrDef { id: "ExcIEEEDC1A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (KA) (> 0). Typical value = 46." },
2386 AttrDef { id: "ExcIEEEDC1A.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (KE). Typical value = 0." },
2387 AttrDef { id: "ExcIEEEDC1A.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gain (KF) (>= 0). Typical value = 0.1." },
2388 AttrDef { id: "ExcIEEEDC1A.seefd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, EFD1 (SE[EFD1]) (>= 0). Typical value = 0.33." },
2389 AttrDef { id: "ExcIEEEDC1A.seefd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, EFD2 (SE[EFD2]) (>= 0). Typical value = 0,1." },
2390 AttrDef { id: "ExcIEEEDC1A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TA) (> 0). Typical value = 0,06." },
2391 AttrDef { id: "ExcIEEEDC1A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TB) (>= 0). Typical value = 0." },
2392 AttrDef { id: "ExcIEEEDC1A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TC) (>= 0). Typical value = 0." },
2393 AttrDef { id: "ExcIEEEDC1A.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (TE) (> 0). Typical value = 0,46." },
2394 AttrDef { id: "ExcIEEEDC1A.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (TF) (> 0). Typical value = 1." },
2395 AttrDef { id: "ExcIEEEDC1A.uelin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "UEL input (uelin). true = input is connected to the HV gate false = input connects to the error signal. Typical value = true." },
2396 AttrDef { id: "ExcIEEEDC1A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VRMAX) (> ExcIEEEDC1A.vrmin). Typical value = 1." },
2397 AttrDef { id: "ExcIEEEDC1A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VRMIN) (< 0 and < ExcIEEEDC1A.vrmax). Typical value = -0,9." },
2398 ],
2399 },
2400 ClassDef {
2401 ns: "http://iec.ch/TC57/CIM100#",
2402 local: "ExcIEEEDC2A",
2403 qualified: "ExcIEEEDC2A",
2404 super_class: Some(161),
2405 concrete: true,
2406 origins: &["DY"],
2407 comment: "IEEE 421.5-2005 type DC2A model. This model represents field-controlled DC commutator exciters with continuously acting voltage regulators having supplies obtained from the generator or auxiliary bus. It differs from the type DC1A model only in the voltage regulator output limits, which are now proportional to terminal voltage VT. It is representative of solid-state replacements for various forms of older mechanical and rotating amplifier regulating equipment connected to DC commutator exciters. Reference: IEEE 421.5-2005, 5.2.",
2408 attrs: &[
2409 AttrDef { id: "ExcIEEEDC2A.efd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter voltage at which exciter saturation is defined (EFD1) (> 0). Typical value = 3,05." },
2410 AttrDef { id: "ExcIEEEDC2A.efd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter voltage at which exciter saturation is defined (EFD2) (> 0). Typical value = 2,29." },
2411 AttrDef { id: "ExcIEEEDC2A.exclim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "(exclim). IEEE standard is ambiguous about lower limit on exciter output. Typical value = - 999 which means that there is no limit applied." },
2412 AttrDef { id: "ExcIEEEDC2A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (KA) (> 0). Typical value = 300." },
2413 AttrDef { id: "ExcIEEEDC2A.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (KE). Typical value = 1." },
2414 AttrDef { id: "ExcIEEEDC2A.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gain (KF) (>= 0). Typical value = 0,1." },
2415 AttrDef { id: "ExcIEEEDC2A.seefd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, EFD1 (SE[EFD1]) (>= 0). Typical value = 0,279." },
2416 AttrDef { id: "ExcIEEEDC2A.seefd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, EFD2 (SE[EFD2]) (>= 0). Typical value = 0,117." },
2417 AttrDef { id: "ExcIEEEDC2A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TA) (> 0). Typical value = 0,01." },
2418 AttrDef { id: "ExcIEEEDC2A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TB) (>= 0). Typical value = 0." },
2419 AttrDef { id: "ExcIEEEDC2A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TC) (>= 0). Typical value = 0." },
2420 AttrDef { id: "ExcIEEEDC2A.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (TE) (> 0). Typical value = 1,33." },
2421 AttrDef { id: "ExcIEEEDC2A.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (TF) (> 0). Typical value = 0,675." },
2422 AttrDef { id: "ExcIEEEDC2A.uelin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "UEL input (uelin). true = input is connected to the HV gate false = input connects to the error signal. Typical value = true." },
2423 AttrDef { id: "ExcIEEEDC2A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VRMAX)(> ExcIEEEDC2A.vrmin). Typical value = 4,95." },
2424 AttrDef { id: "ExcIEEEDC2A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VRMIN) (< 0 and < ExcIEEEDC2A.vrmax). Typical value = -4,9." },
2425 ],
2426 },
2427 ClassDef {
2428 ns: "http://iec.ch/TC57/CIM100#",
2429 local: "ExcIEEEDC3A",
2430 qualified: "ExcIEEEDC3A",
2431 super_class: Some(161),
2432 concrete: true,
2433 origins: &["DY"],
2434 comment: "IEEE 421.5-2005 type DC3A model. This model represents older systems, in particular those DC commutator exciters with non-continuously acting regulators that were commonly used before the development of the continuously acting varieties. These systems respond at basically two different rates, depending upon the magnitude of voltage error. For small errors, adjustment is made periodically with a signal to a motor-operated rheostat. Larger errors cause resistors to be quickly shorted or inserted and a strong forcing signal applied to the exciter. Continuous motion of the motor-operated rheostat occurs for these larger error signals, even though it is bypassed by contactor action. Reference: IEEE 421.5-2005, 5.3.",
2435 attrs: &[
2436 AttrDef { id: "ExcIEEEDC3A.efd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter voltage at which exciter saturation is defined (EFD1) (> 0). Typical value = 3,375." },
2437 AttrDef { id: "ExcIEEEDC3A.efd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter voltage at which exciter saturation is defined (EFD2) (> 0). Typical value = 3,15." },
2438 AttrDef { id: "ExcIEEEDC3A.exclim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "(exclim). IEEE standard is ambiguous about lower limit on exciter output. true = a lower limit of zero is applied to integrator output false = a lower limit of zero is not applied to integrator output. Typical value = true." },
2439 AttrDef { id: "ExcIEEEDC3A.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (KE). Typical value = 0,05." },
2440 AttrDef { id: "ExcIEEEDC3A.kv", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fast raise/lower contact setting (KV) (> 0). Typical value = 0,05." },
2441 AttrDef { id: "ExcIEEEDC3A.seefd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, EFD1 (SE[EFD1]) (>= 0). Typical value = 0,267." },
2442 AttrDef { id: "ExcIEEEDC3A.seefd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, EFD2 (SE[EFD2]) (>= 0). Typical value = 0,068." },
2443 AttrDef { id: "ExcIEEEDC3A.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (TE) (> 0). Typical value = 0,5." },
2444 AttrDef { id: "ExcIEEEDC3A.trh", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rheostat travel time (TRH) (> 0). Typical value = 20." },
2445 AttrDef { id: "ExcIEEEDC3A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VRMAX) (> 0). Typical value = 1." },
2446 AttrDef { id: "ExcIEEEDC3A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VRMIN) (<= 0). Typical value = 0." },
2447 ],
2448 },
2449 ClassDef {
2450 ns: "http://iec.ch/TC57/CIM100#",
2451 local: "ExcIEEEDC4B",
2452 qualified: "ExcIEEEDC4B",
2453 super_class: Some(161),
2454 concrete: true,
2455 origins: &["DY"],
2456 comment: "IEEE 421.5-2005 type DC4B model. These excitation systems utilize a field-controlled DC commutator exciter with a continuously acting voltage regulator having supplies obtained from the generator or auxiliary bus. Reference: IEEE 421.5-2005, 5.4.",
2457 attrs: &[
2458 AttrDef { id: "ExcIEEEDC4B.efd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter voltage at which exciter saturation is defined (EFD1) (> 0). Typical value = 1,75." },
2459 AttrDef { id: "ExcIEEEDC4B.efd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter voltage at which exciter saturation is defined (EFD2) (> 0). Typical value = 2,33." },
2460 AttrDef { id: "ExcIEEEDC4B.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (KA) (> 0). Typical value = 1." },
2461 AttrDef { id: "ExcIEEEDC4B.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Regulator derivative gain (KD) (>= 0). Typical value = 20." },
2462 AttrDef { id: "ExcIEEEDC4B.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (KE). Typical value = 1." },
2463 AttrDef { id: "ExcIEEEDC4B.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gain (KF) (>= 0). Typical value = 0." },
2464 AttrDef { id: "ExcIEEEDC4B.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Regulator integral gain (KI) (>= 0). Typical value = 20." },
2465 AttrDef { id: "ExcIEEEDC4B.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Regulator proportional gain (KP) (>= 0). Typical value = 20." },
2466 AttrDef { id: "ExcIEEEDC4B.oelin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "OEL input (OELin). true = LV gate false = subtract from error signal. Typical value = true." },
2467 AttrDef { id: "ExcIEEEDC4B.seefd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, EFD1 (SE[EFD1]) (>= 0). Typical value = 0,08." },
2468 AttrDef { id: "ExcIEEEDC4B.seefd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter saturation function value at the corresponding exciter voltage, EFD2 (SE[EFD2]) (>= 0). Typical value = 0,27." },
2469 AttrDef { id: "ExcIEEEDC4B.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TA) (> 0). Typical value = 0,2." },
2470 AttrDef { id: "ExcIEEEDC4B.td", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Regulator derivative filter time constant (TD) (> 0 if ExcIEEEDC4B.kd > 0). Typical value = 0,01." },
2471 AttrDef { id: "ExcIEEEDC4B.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (TE) (> 0). Typical value = 0,8." },
2472 AttrDef { id: "ExcIEEEDC4B.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (TF) (>= 0). Typical value = 1." },
2473 AttrDef { id: "ExcIEEEDC4B.uelin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "UEL input (UELin). true = HV gate false = add to error signal. Typical value = true." },
2474 AttrDef { id: "ExcIEEEDC4B.vemin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum exciter voltage output (VEMIN) (<= 0). Typical value = 0." },
2475 AttrDef { id: "ExcIEEEDC4B.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VRMAX) (> ExcIEEEDC4B.vrmin). Typical value = 2,7." },
2476 AttrDef { id: "ExcIEEEDC4B.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VRMIN) (<= 0 and < ExcIEEEDC4B.vrmax). Typical value = -0,9." },
2477 ],
2478 },
2479 ClassDef {
2480 ns: "http://iec.ch/TC57/CIM100#",
2481 local: "ExcIEEEST1A",
2482 qualified: "ExcIEEEST1A",
2483 super_class: Some(161),
2484 concrete: true,
2485 origins: &["DY"],
2486 comment: "IEEE 421.5-2005 type ST1A model. This model represents systems in which excitation power is supplied through a transformer from the generator terminals (or the unit’s auxiliary bus) and is regulated by a controlled rectifier. The maximum exciter voltage available from such systems is directly related to the generator terminal voltage. Reference: IEEE 421.5-2005, 7.1.",
2487 attrs: &[
2488 AttrDef { id: "ExcIEEEST1A.ilr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter output current limit reference (ILR). Typical value = 0." },
2489 AttrDef { id: "ExcIEEEST1A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (KA) (> 0). Typical value = 190." },
2490 AttrDef { id: "ExcIEEEST1A.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (KC) (>= 0). Typical value = 0,08." },
2491 AttrDef { id: "ExcIEEEST1A.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gains (KF) (>= 0). Typical value = 0." },
2492 AttrDef { id: "ExcIEEEST1A.klr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter output current limiter gain (KLR). Typical value = 0." },
2493 AttrDef { id: "ExcIEEEST1A.pssin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Selector of the Power System Stabilizer (PSS) input (PSSin). true = PSS input (Vs) added to error signal false = PSS input (Vs) added to voltage regulator output. Typical value = true." },
2494 AttrDef { id: "ExcIEEEST1A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TA) (>= 0). Typical value = 0." },
2495 AttrDef { id: "ExcIEEEST1A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TB) (>= 0). Typical value = 10." },
2496 AttrDef { id: "ExcIEEEST1A.tb1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TB1) (>= 0). Typical value = 0." },
2497 AttrDef { id: "ExcIEEEST1A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TC) (>= 0). Typical value = 1." },
2498 AttrDef { id: "ExcIEEEST1A.tc1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TC1) (>= 0). Typical value = 0." },
2499 AttrDef { id: "ExcIEEEST1A.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (TF) (>= 0). Typical value = 1." },
2500 AttrDef { id: "ExcIEEEST1A.uelin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "ExcIEEEST1AUELselectorKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Selector of the connection of the UEL input (UELin). Typical value = ignoreUELsignal." },
2501 AttrDef { id: "ExcIEEEST1A.vamax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VAMAX) (> 0). Typical value = 14,5." },
2502 AttrDef { id: "ExcIEEEST1A.vamin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VAMIN) (< 0). Typical value = -14,5." },
2503 AttrDef { id: "ExcIEEEST1A.vimax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator input limit (VIMAX) (> 0). Typical value = 999." },
2504 AttrDef { id: "ExcIEEEST1A.vimin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator input limit (VIMIN) (< 0). Typical value = -999." },
2505 AttrDef { id: "ExcIEEEST1A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator outputs (VRMAX) (> 0). Typical value = 7,8." },
2506 AttrDef { id: "ExcIEEEST1A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator outputs (VRMIN) (< 0). Typical value = -6,7." },
2507 ],
2508 },
2509 ClassDef {
2510 ns: "http://iec.ch/TC57/CIM100#",
2511 local: "ExcIEEEST2A",
2512 qualified: "ExcIEEEST2A",
2513 super_class: Some(161),
2514 concrete: true,
2515 origins: &["DY"],
2516 comment: "IEEE 421.5-2005 type ST2A model. Some static systems use both current and voltage sources (generator terminal quantities) to comprise the power source. The regulator controls the exciter output through controlled saturation of the power transformer components. These compound-source rectifier excitation systems are designated type ST2A and are represented by ExcIEEEST2A. Reference: IEEE 421.5-2005, 7.2.",
2517 attrs: &[
2518 AttrDef { id: "ExcIEEEST2A.efdmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum field voltage (EFDMax) (>= 0). Typical value = 99." },
2519 AttrDef { id: "ExcIEEEST2A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (KA) (> 0). Typical value = 120." },
2520 AttrDef { id: "ExcIEEEST2A.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (KC) (>= 0). Typical value = 1,82." },
2521 AttrDef { id: "ExcIEEEST2A.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (KE). Typical value = 1." },
2522 AttrDef { id: "ExcIEEEST2A.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gains (KF) (>= 0). Typical value = 0,05." },
2523 AttrDef { id: "ExcIEEEST2A.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential circuit gain coefficient (KI) (>= 0). Typical value = 8." },
2524 AttrDef { id: "ExcIEEEST2A.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential circuit gain coefficient (KP) (>= 0). Typical value = 4,88." },
2525 AttrDef { id: "ExcIEEEST2A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TA) (> 0). Typical value = 0,15." },
2526 AttrDef { id: "ExcIEEEST2A.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (TE) (> 0). Typical value = 0,5." },
2527 AttrDef { id: "ExcIEEEST2A.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (TF) (>= 0). Typical value = 1." },
2528 AttrDef { id: "ExcIEEEST2A.uelin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "UEL input (UELin). true = HV gate false = add to error signal. Typical value = true." },
2529 AttrDef { id: "ExcIEEEST2A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator outputs (VRMAX) (> 0). Typical value = 1." },
2530 AttrDef { id: "ExcIEEEST2A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator outputs (VRMIN) (<= 0). Typical value = 0." },
2531 ],
2532 },
2533 ClassDef {
2534 ns: "http://iec.ch/TC57/CIM100#",
2535 local: "ExcIEEEST3A",
2536 qualified: "ExcIEEEST3A",
2537 super_class: Some(161),
2538 concrete: true,
2539 origins: &["DY"],
2540 comment: "IEEE 421.5-2005 type ST3A model. Some static systems utilize a field voltage control loop to linearize the exciter control characteristic. This also makes the output independent of supply source variations until supply limitations are reached. These systems utilize a variety of controlled-rectifier designs: full thyristor complements or hybrid bridges in either series or shunt configurations. The power source can consist of only a potential source, either fed from the machine terminals or from internal windings. Some designs can have compound power sources utilizing both machine potential and current. These power sources are represented as phasor combinations of machine terminal current and voltage and are accommodated by suitable parameters in model type ST3A which is represented by ExcIEEEST3A. Reference: IEEE 421.5-2005, 7.3.",
2541 attrs: &[
2542 AttrDef { id: "ExcIEEEST3A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (KA) (> 0). This is parameter K in the IEEE standard. Typical value = 200." },
2543 AttrDef { id: "ExcIEEEST3A.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (KC) (>= 0). Typical value = 0,2." },
2544 AttrDef { id: "ExcIEEEST3A.kg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Feedback gain constant of the inner loop field regulator (KG) (>= 0). Typical value = 1." },
2545 AttrDef { id: "ExcIEEEST3A.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential circuit gain coefficient (KI) (>= 0). Typical value = 0." },
2546 AttrDef { id: "ExcIEEEST3A.km", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Forward gain constant of the inner loop field regulator (KM) (> 0). Typical value = 7,93." },
2547 AttrDef { id: "ExcIEEEST3A.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential circuit gain coefficient (KP) (> 0). Typical value = 6,15." },
2548 AttrDef { id: "ExcIEEEST3A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TA) (>= 0). Typical value = 0." },
2549 AttrDef { id: "ExcIEEEST3A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TB) (>= 0). Typical value = 10." },
2550 AttrDef { id: "ExcIEEEST3A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TC) (>= 0). Typical value = 1." },
2551 AttrDef { id: "ExcIEEEST3A.thetap", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential circuit phase angle (thetap). Typical value = 0." },
2552 AttrDef { id: "ExcIEEEST3A.tm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Forward time constant of inner loop field regulator (TM) (> 0). Typical value = 0,4." },
2553 AttrDef { id: "ExcIEEEST3A.vbmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum excitation voltage (VBMax) (> 0). Typical value = 6,9." },
2554 AttrDef { id: "ExcIEEEST3A.vgmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum inner loop feedback voltage (VGMax) (>= 0). Typical value = 5,8." },
2555 AttrDef { id: "ExcIEEEST3A.vimax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator input limit (VIMAX) (> 0). Typical value = 0,2." },
2556 AttrDef { id: "ExcIEEEST3A.vimin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator input limit (VIMIN) (< 0). Typical value = -0,2." },
2557 AttrDef { id: "ExcIEEEST3A.vmmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum inner loop output (VMMax) (> 0). Typical value = 1." },
2558 AttrDef { id: "ExcIEEEST3A.vmmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum inner loop output (VMMin) (<= 0). Typical value = 0." },
2559 AttrDef { id: "ExcIEEEST3A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VRMAX) (> 0). Typical value = 10." },
2560 AttrDef { id: "ExcIEEEST3A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VRMIN) (< 0). Typical value = -10." },
2561 AttrDef { id: "ExcIEEEST3A.xl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactance associated with potential source (XL) (>= 0). Typical value = 0,081." },
2562 ],
2563 },
2564 ClassDef {
2565 ns: "http://iec.ch/TC57/CIM100#",
2566 local: "ExcIEEEST4B",
2567 qualified: "ExcIEEEST4B",
2568 super_class: Some(161),
2569 concrete: true,
2570 origins: &["DY"],
2571 comment: "IEEE 421.5-2005 type ST4B model. This model is a variation of the type ST3A model, with a proportional plus integral (PI) regulator block replacing the lag-lead regulator characteristic that is in the ST3A model. Both potential and compound source rectifier excitation systems are modelled. The PI regulator blocks have non-windup limits that are represented. The voltage regulator of this model is typically implemented digitally. Reference: IEEE 421.5-2005, 7.4.",
2572 attrs: &[
2573 AttrDef { id: "ExcIEEEST4B.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (KC) (>= 0). Typical value = 0,113." },
2574 AttrDef { id: "ExcIEEEST4B.kg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Feedback gain constant of the inner loop field regulator (KG) (>= 0). Typical value = 0." },
2575 AttrDef { id: "ExcIEEEST4B.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential circuit gain coefficient (KI) (>= 0). Typical value = 0." },
2576 AttrDef { id: "ExcIEEEST4B.kim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator integral gain output (KIM). Typical value = 0." },
2577 AttrDef { id: "ExcIEEEST4B.kir", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator integral gain (KIR). Typical value = 10,75." },
2578 AttrDef { id: "ExcIEEEST4B.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential circuit gain coefficient (KP) (> 0). Typical value = 9,3." },
2579 AttrDef { id: "ExcIEEEST4B.kpm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator proportional gain output (KPM). Typical value = 1." },
2580 AttrDef { id: "ExcIEEEST4B.kpr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator proportional gain (KPR). Typical value = 10,75." },
2581 AttrDef { id: "ExcIEEEST4B.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (TA) (>= 0). Typical value = 0,02." },
2582 AttrDef { id: "ExcIEEEST4B.thetap", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential circuit phase angle (thetap). Typical value = 0." },
2583 AttrDef { id: "ExcIEEEST4B.vbmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum excitation voltage (VBMax) (> 0). Typical value = 11,63." },
2584 AttrDef { id: "ExcIEEEST4B.vmmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum inner loop output (VMMax) (> ExcIEEEST4B.vmmin). Typical value = 99." },
2585 AttrDef { id: "ExcIEEEST4B.vmmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum inner loop output (VMMin) (< ExcIEEEST4B.vmmax). Typical value = -99." },
2586 AttrDef { id: "ExcIEEEST4B.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VRMAX) (> 0). Typical value = 1." },
2587 AttrDef { id: "ExcIEEEST4B.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VRMIN) (< 0). Typical value = -0,87." },
2588 AttrDef { id: "ExcIEEEST4B.xl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactance associated with potential source (XL) (>= 0). Typical value = 0,124." },
2589 ],
2590 },
2591 ClassDef {
2592 ns: "http://iec.ch/TC57/CIM100#",
2593 local: "ExcIEEEST5B",
2594 qualified: "ExcIEEEST5B",
2595 super_class: Some(161),
2596 concrete: true,
2597 origins: &["DY"],
2598 comment: "IEEE 421.5-2005 type ST5B model. The type ST5B excitation system is a variation of the type ST1A model, with alternative overexcitation and underexcitation inputs and additional limits. The block diagram in the IEEE 421.5 standard has input signal Vc and does not indicate the summation point with Vref. The implementation of the ExcIEEEST5B shall consider summation point with Vref. Reference: IEEE 421.5-2005, 7.5.",
2599 attrs: &[
2600 AttrDef { id: "ExcIEEEST5B.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier regulation factor (KC) (>= 0). Typical value = 0,004." },
2601 AttrDef { id: "ExcIEEEST5B.kr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Regulator gain (KR) (> 0). Typical value = 200." },
2602 AttrDef { id: "ExcIEEEST5B.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Firing circuit time constant (T1) (>= 0). Typical value = 0,004." },
2603 AttrDef { id: "ExcIEEEST5B.tb1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Regulator lag time constant (TB1) (>= 0). Typical value = 6." },
2604 AttrDef { id: "ExcIEEEST5B.tb2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Regulator lag time constant (TB2) (>= 0). Typical value = 0,01." },
2605 AttrDef { id: "ExcIEEEST5B.tc1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Regulator lead time constant (TC1) (>= 0). Typical value = 0,8." },
2606 AttrDef { id: "ExcIEEEST5B.tc2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Regulator lead time constant (TC2) (>= 0). Typical value = 0,08." },
2607 AttrDef { id: "ExcIEEEST5B.tob1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "OEL lag time constant (TOB1) (>= 0). Typical value = 2." },
2608 AttrDef { id: "ExcIEEEST5B.tob2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "OEL lag time constant (TOB2) (>= 0). Typical value = 0,08." },
2609 AttrDef { id: "ExcIEEEST5B.toc1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "OEL lead time constant (TOC1) (>= 0). Typical value = 0,1." },
2610 AttrDef { id: "ExcIEEEST5B.toc2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "OEL lead time constant (TOC2) (>= 0). Typical value = 0,08." },
2611 AttrDef { id: "ExcIEEEST5B.tub1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL lag time constant (TUB1) (>= 0). Typical value = 10." },
2612 AttrDef { id: "ExcIEEEST5B.tub2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL lag time constant (TUB2) (>= 0). Typical value = 0,05." },
2613 AttrDef { id: "ExcIEEEST5B.tuc1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL lead time constant (TUC1) (>= 0). Typical value = 2." },
2614 AttrDef { id: "ExcIEEEST5B.tuc2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL lead time constant (TUC2) (>= 0). Typical value = 0,1." },
2615 AttrDef { id: "ExcIEEEST5B.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VRMAX) (> 0). Typical value = 5." },
2616 AttrDef { id: "ExcIEEEST5B.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VRMIN) (< 0). Typical value = -4." },
2617 ],
2618 },
2619 ClassDef {
2620 ns: "http://iec.ch/TC57/CIM100#",
2621 local: "ExcIEEEST6B",
2622 qualified: "ExcIEEEST6B",
2623 super_class: Some(161),
2624 concrete: true,
2625 origins: &["DY"],
2626 comment: "IEEE 421.5-2005 type ST6B model. This model consists of a PI voltage regulator with an inner loop field voltage regulator and pre-control. The field voltage regulator implements a proportional control. The pre-control and the delay in the feedback circuit increase the dynamic response. Reference: IEEE 421.5-2005, 7.6.",
2627 attrs: &[
2628 AttrDef { id: "ExcIEEEST6B.ilr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter output current limit reference (ILR) (> 0). Typical value = 4,164." },
2629 AttrDef { id: "ExcIEEEST6B.kci", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter output current limit adjustment (KCI) (> 0). Typical value = 1,0577." },
2630 AttrDef { id: "ExcIEEEST6B.kff", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pre-control gain constant of the inner loop field regulator (KFF). Typical value = 1." },
2631 AttrDef { id: "ExcIEEEST6B.kg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Feedback gain constant of the inner loop field regulator (KG) (>= 0). Typical value = 1." },
2632 AttrDef { id: "ExcIEEEST6B.kia", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator integral gain (KIA) (> 0). Typical value = 45,094." },
2633 AttrDef { id: "ExcIEEEST6B.klr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter output current limiter gain (KLR) (> 0). Typical value = 17,33." },
2634 AttrDef { id: "ExcIEEEST6B.km", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Forward gain constant of the inner loop field regulator (KM). Typical value = 1." },
2635 AttrDef { id: "ExcIEEEST6B.kpa", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator proportional gain (KPA) (> 0). Typical value = 18,038." },
2636 AttrDef { id: "ExcIEEEST6B.oelin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "ExcST6BOELselectorKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "OEL input selector (OELin). Typical value = noOELinput." },
2637 AttrDef { id: "ExcIEEEST6B.tg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Feedback time constant of inner loop field voltage regulator (TG) (>= 0). Typical value = 0,02." },
2638 AttrDef { id: "ExcIEEEST6B.vamax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VAMAX) (> 0). Typical value = 4,81." },
2639 AttrDef { id: "ExcIEEEST6B.vamin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VAMIN) (< 0). Typical value = -3,85." },
2640 AttrDef { id: "ExcIEEEST6B.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VRMAX) (> 0). Typical value = 4,81." },
2641 AttrDef { id: "ExcIEEEST6B.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VRMIN) (< 0). Typical value = -3,85." },
2642 ],
2643 },
2644 ClassDef {
2645 ns: "http://iec.ch/TC57/CIM100#",
2646 local: "ExcIEEEST7B",
2647 qualified: "ExcIEEEST7B",
2648 super_class: Some(161),
2649 concrete: true,
2650 origins: &["DY"],
2651 comment: "IEEE 421.5-2005 type ST7B model. This model is representative of static potential-source excitation systems. In this system, the AVR consists of a PI voltage regulator. A phase lead-lag filter in series allows the introduction of a derivative function, typically used with brushless excitation systems. In that case, the regulator is of the PID type. In addition, the terminal voltage channel includes a phase lead-lag filter. The AVR includes the appropriate inputs on its reference for overexcitation limiter (OEL1), underexcitation limiter (UEL), stator current limiter (SCL), and current compensator (DROOP). All these limitations, when they work at voltage reference level, keep the PSS (VS signal from PSS) in operation. However, the UEL limitation can also be transferred to the high value (HV) gate acting on the output signal. In addition, the output signal passes through a low value (LV) gate for a ceiling overexcitation limiter (OEL2). Reference: IEEE 421.5-2005, 7.7.",
2652 attrs: &[
2653 AttrDef { id: "ExcIEEEST7B.kh", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High-value gate feedback gain (KH) (>= 0). Typical value = 1." },
2654 AttrDef { id: "ExcIEEEST7B.kia", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator integral gain (KIA) (>= 0). Typical value = 1." },
2655 AttrDef { id: "ExcIEEEST7B.kl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low-value gate feedback gain (KL) (>= 0). Typical value = 1." },
2656 AttrDef { id: "ExcIEEEST7B.kpa", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator proportional gain (KPA) (> 0). Typical value = 40." },
2657 AttrDef { id: "ExcIEEEST7B.oelin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "ExcST7BOELselectorKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "OEL input selector (OELin). Typical value = noOELinput." },
2658 AttrDef { id: "ExcIEEEST7B.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Regulator lag time constant (TB) (>= 0). Typical value = 1." },
2659 AttrDef { id: "ExcIEEEST7B.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Regulator lead time constant (TC) (>= 0). Typical value = 1." },
2660 AttrDef { id: "ExcIEEEST7B.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (TF) (>= 0). Typical value = 1." },
2661 AttrDef { id: "ExcIEEEST7B.tg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Feedback time constant of inner loop field voltage regulator (TG) (>= 0). Typical value = 1." },
2662 AttrDef { id: "ExcIEEEST7B.tia", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Feedback time constant (TIA) (>= 0). Typical value = 3." },
2663 AttrDef { id: "ExcIEEEST7B.uelin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "ExcST7BUELselectorKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "UEL input selector (UELin). Typical value = noUELinput." },
2664 AttrDef { id: "ExcIEEEST7B.vmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage reference signal (VMAX) (> 0 and > ExcIEEEST7B.vmin). Typical value = 1,1." },
2665 AttrDef { id: "ExcIEEEST7B.vmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage reference signal (VMIN) (> 0 and < ExcIEEEST7B.vmax). Typical value = 0,9." },
2666 AttrDef { id: "ExcIEEEST7B.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (VRMAX) (> 0). Typical value = 5." },
2667 AttrDef { id: "ExcIEEEST7B.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (VRMIN) (< 0). Typical value = -4,5." },
2668 ],
2669 },
2670 ClassDef {
2671 ns: "http://iec.ch/TC57/CIM100#",
2672 local: "ExcNI",
2673 qualified: "ExcNI",
2674 super_class: Some(161),
2675 concrete: true,
2676 origins: &["DY"],
2677 comment: "Bus or solid fed SCR (silicon-controlled rectifier) bridge excitation system model type NI (NVE).",
2678 attrs: &[
2679 AttrDef { id: "ExcNI.busFedSelector", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Fed by selector (BusFedSelector). true = bus fed (switch is closed) false = solid fed (switch is open). Typical value = true." },
2680 AttrDef { id: "ExcNI.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (Ka) (> 0). Typical value = 210." },
2681 AttrDef { id: "ExcNI.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gain (Kf) (> 0). Typical value 0,01." },
2682 AttrDef { id: "ExcNI.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "rc / rfd (R) (>= 0). 0 means exciter has negative current capability > 0 means exciter does not have negative current capability. Typical value = 5." },
2683 AttrDef { id: "ExcNI.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Ta) (> 0). Typical value = 0,02." },
2684 AttrDef { id: "ExcNI.tf1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (Tf1) (> 0). Typical value = 1,0." },
2685 AttrDef { id: "ExcNI.tf2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (Tf2) (> 0). Typical value = 0,1." },
2686 AttrDef { id: "ExcNI.tr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Tr) (>= 0). Typical value = 0,02." },
2687 AttrDef { id: "ExcNI.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator ouput (Vrmax) (> ExcNI.vrmin). Typical value = 5,0." },
2688 AttrDef { id: "ExcNI.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator ouput (Vrmin) (< ExcNI.vrmax). Typical value = -2,0." },
2689 ],
2690 },
2691 ClassDef {
2692 ns: "http://iec.ch/TC57/CIM100#",
2693 local: "ExcOEX3T",
2694 qualified: "ExcOEX3T",
2695 super_class: Some(161),
2696 concrete: true,
2697 origins: &["DY"],
2698 comment: "Modified IEEE type ST1 excitation system with semi-continuous and acting terminal voltage limiter.",
2699 attrs: &[
2700 AttrDef { id: "ExcOEX3T.e1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Saturation parameter (E1)." },
2701 AttrDef { id: "ExcOEX3T.e2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Saturation parameter (E2)." },
2702 AttrDef { id: "ExcOEX3T.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (KA)." },
2703 AttrDef { id: "ExcOEX3T.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (KC)." },
2704 AttrDef { id: "ExcOEX3T.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (KD)." },
2705 AttrDef { id: "ExcOEX3T.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (KE)." },
2706 AttrDef { id: "ExcOEX3T.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (KF)." },
2707 AttrDef { id: "ExcOEX3T.see1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Saturation parameter (SE[E1])." },
2708 AttrDef { id: "ExcOEX3T.see2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Saturation parameter (SE[E2])." },
2709 AttrDef { id: "ExcOEX3T.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T1) (>= 0)." },
2710 AttrDef { id: "ExcOEX3T.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T2) (>= 0)." },
2711 AttrDef { id: "ExcOEX3T.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T3) (>= 0)." },
2712 AttrDef { id: "ExcOEX3T.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T4) (>= 0)." },
2713 AttrDef { id: "ExcOEX3T.t5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T5) (>= 0)." },
2714 AttrDef { id: "ExcOEX3T.t6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T6) (>= 0)." },
2715 AttrDef { id: "ExcOEX3T.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (TE) (>= 0)." },
2716 AttrDef { id: "ExcOEX3T.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (TF) (>= 0)." },
2717 AttrDef { id: "ExcOEX3T.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter (VRMAX) (> ExcOEX3T.vrmin)." },
2718 AttrDef { id: "ExcOEX3T.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter (VRMIN) (< ExcOEX3T.vrmax)." },
2719 ],
2720 },
2721 ClassDef {
2722 ns: "http://iec.ch/TC57/CIM100#",
2723 local: "ExcPIC",
2724 qualified: "ExcPIC",
2725 super_class: Some(161),
2726 concrete: true,
2727 origins: &["DY"],
2728 comment: "Proportional/integral regulator excitation system. This model can be used to represent excitation systems with a proportional-integral (PI) voltage regulator controller.",
2729 attrs: &[
2730 AttrDef { id: "ExcPIC.e1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field voltage value 1 (E1). Typical value = 0." },
2731 AttrDef { id: "ExcPIC.e2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field voltage value 2 (E2). Typical value = 0." },
2732 AttrDef { id: "ExcPIC.efdmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter maximum limit (Efdmax) (> ExcPIC.efdmin). Typical value = 8." },
2733 AttrDef { id: "ExcPIC.efdmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter minimum limit (Efdmin) (< ExcPIC.efdmax). Typical value = -0,87." },
2734 AttrDef { id: "ExcPIC.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PI controller gain (Ka). Typical value = 3,15." },
2735 AttrDef { id: "ExcPIC.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter regulation factor (Kc). Typical value = 0,08." },
2736 AttrDef { id: "ExcPIC.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant (Ke). Typical value = 0." },
2737 AttrDef { id: "ExcPIC.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rate feedback gain (Kf). Typical value = 0." },
2738 AttrDef { id: "ExcPIC.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Current source gain (Ki). Typical value = 0." },
2739 AttrDef { id: "ExcPIC.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential source gain (Kp). Typical value = 6,5." },
2740 AttrDef { id: "ExcPIC.se1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Saturation factor at E1 (Se1). Typical value = 0." },
2741 AttrDef { id: "ExcPIC.se2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Saturation factor at E2 (Se2). Typical value = 0." },
2742 AttrDef { id: "ExcPIC.ta1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PI controller time constant (Ta1) (>= 0). Typical value = 1." },
2743 AttrDef { id: "ExcPIC.ta2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Ta2) (>= 0). Typical value = 0,01." },
2744 AttrDef { id: "ExcPIC.ta3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead time constant (Ta3) (>= 0). Typical value = 0." },
2745 AttrDef { id: "ExcPIC.ta4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant (Ta4) (>= 0). Typical value = 0." },
2746 AttrDef { id: "ExcPIC.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant (Te) (>= 0). Typical value = 0." },
2747 AttrDef { id: "ExcPIC.tf1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rate feedback time constant (Tf1) (>= 0). Typical value = 0." },
2748 AttrDef { id: "ExcPIC.tf2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rate feedback lag time constant (Tf2) (>= 0). Typical value = 0." },
2749 AttrDef { id: "ExcPIC.vr1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PI maximum limit (Vr1). Typical value = 1." },
2750 AttrDef { id: "ExcPIC.vr2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PI minimum limit (Vr2). Typical value = -0,87." },
2751 AttrDef { id: "ExcPIC.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator maximum limit (Vrmax) (> ExcPIC.vrmin). Typical value = 1." },
2752 AttrDef { id: "ExcPIC.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator minimum limit (Vrmin) (< ExcPIC.vrmax). Typical value = -0,87." },
2753 ],
2754 },
2755 ClassDef {
2756 ns: "http://iec.ch/TC57/CIM100#",
2757 local: "ExcREXS",
2758 qualified: "ExcREXS",
2759 super_class: Some(161),
2760 concrete: true,
2761 origins: &["DY"],
2762 comment: "General purpose rotating excitation system. This model can be used to represent a wide range of excitation systems whose DC power source is an AC or DC generator. It encompasses IEEE type AC1, AC2, DC1, and DC2 excitation system models.",
2763 attrs: &[
2764 AttrDef { id: "ExcREXS.e1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field voltage value 1 (E1). Typical value = 3." },
2765 AttrDef { id: "ExcREXS.e2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field voltage value 2 (E2). Typical value = 4." },
2766 AttrDef { id: "ExcREXS.fbf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "ExcREXSFeedbackSignalKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Rate feedback signal flag (fbf). Typical value = fieldCurrent." },
2767 AttrDef { id: "ExcREXS.flimf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limit type flag (Flimf). Typical value = 0." },
2768 AttrDef { id: "ExcREXS.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier regulation factor (Kc). Typical value = 0,05." },
2769 AttrDef { id: "ExcREXS.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter regulation factor (Kd). Typical value = 2." },
2770 AttrDef { id: "ExcREXS.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field proportional constant (Ke). Typical value = 1." },
2771 AttrDef { id: "ExcREXS.kefd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field voltage feedback gain (Kefd). Typical value = 0." },
2772 AttrDef { id: "ExcREXS.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rate feedback gain (Kf) (>= 0). Typical value = 0,05." },
2773 AttrDef { id: "ExcREXS.kh", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field voltage controller feedback gain (Kh). Typical value = 0." },
2774 AttrDef { id: "ExcREXS.kii", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field current regulator integral gain (Kii). Typical value = 0." },
2775 AttrDef { id: "ExcREXS.kip", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field current regulator proportional gain (Kip). Typical value = 1." },
2776 AttrDef { id: "ExcREXS.ks", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient to allow different usage of the model-speed coefficient (Ks). Typical value = 0." },
2777 AttrDef { id: "ExcREXS.kvi", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator integral gain (Kvi). Typical value = 0." },
2778 AttrDef { id: "ExcREXS.kvp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator proportional gain (Kvp). Typical value = 2800." },
2779 AttrDef { id: "ExcREXS.kvphz", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "V/Hz limiter gain (Kvphz). Typical value = 0." },
2780 AttrDef { id: "ExcREXS.nvphz", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pickup speed of V/Hz limiter (Nvphz). Typical value = 0." },
2781 AttrDef { id: "ExcREXS.se1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Saturation factor at E1 (Se1). Typical value = 0,0001." },
2782 AttrDef { id: "ExcREXS.se2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Saturation factor at E2 (Se2). Typical value = 0,001." },
2783 AttrDef { id: "ExcREXS.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Ta) (>= 0). If = 0, block is bypassed. Typical value = 0,01." },
2784 AttrDef { id: "ExcREXS.tb1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant (Tb1) (>= 0). If = 0, block is bypassed. Typical value = 0." },
2785 AttrDef { id: "ExcREXS.tb2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant (Tb2) (>= 0). If = 0, block is bypassed. Typical value = 0." },
2786 AttrDef { id: "ExcREXS.tc1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead time constant (Tc1) (>= 0). Typical value = 0." },
2787 AttrDef { id: "ExcREXS.tc2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead time constant (Tc2) (>= 0). Typical value = 0." },
2788 AttrDef { id: "ExcREXS.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter field time constant (Te) (> 0). Typical value = 1,2." },
2789 AttrDef { id: "ExcREXS.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rate feedback time constant (Tf) (>= 0). If = 0, the feedback path is not used. Typical value = 1." },
2790 AttrDef { id: "ExcREXS.tf1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Feedback lead time constant (Tf1) (>= 0). Typical value = 0." },
2791 AttrDef { id: "ExcREXS.tf2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Feedback lag time constant (Tf2) (>= 0). If = 0, block is bypassed. Typical value = 0." },
2792 AttrDef { id: "ExcREXS.tp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field current bridge time constant (Tp) (>= 0). Typical value = 0." },
2793 AttrDef { id: "ExcREXS.vcmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum compounding voltage (Vcmax). Typical value = 0." },
2794 AttrDef { id: "ExcREXS.vfmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum exciter field current (Vfmax) (> ExcREXS.vfmin). Typical value = 47." },
2795 AttrDef { id: "ExcREXS.vfmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum exciter field current (Vfmin) (< ExcREXS.vfmax). Typical value = -20." },
2796 AttrDef { id: "ExcREXS.vimax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator input limit (Vimax). Typical value = 0,1." },
2797 AttrDef { id: "ExcREXS.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum controller output (Vrmax) (> ExcREXS.vrmin). Typical value = 47." },
2798 AttrDef { id: "ExcREXS.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum controller output (Vrmin) (< ExcREXS.vrmax). Typical value = -20." },
2799 AttrDef { id: "ExcREXS.xc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter compounding reactance (Xc). Typical value = 0." },
2800 ],
2801 },
2802 ClassDef {
2803 ns: "http://iec.ch/TC57/CIM100#",
2804 local: "ExcRQB",
2805 qualified: "ExcRQB",
2806 super_class: Some(161),
2807 concrete: true,
2808 origins: &["DY"],
2809 comment: "Excitation system type RQB (four-loop regulator, r?gulateur quatre boucles, developed in France) primarily used in nuclear or thermal generating units. This excitation system shall be always used together with power system stabilizer type PssRQB.",
2810 attrs: &[
2811 AttrDef { id: "ExcRQB.ki0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage reference input gain (Ki0). Typical value = 12,7." },
2812 AttrDef { id: "ExcRQB.ki1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage input gain (Ki1). Typical value = -16,8." },
2813 AttrDef { id: "ExcRQB.klir", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "OEL input gain (KLIR). Typical value = 12,13." },
2814 AttrDef { id: "ExcRQB.klus", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter gain (KLUS). Typical value = 50." },
2815 AttrDef { id: "ExcRQB.lsat", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Integrator limiter (LSAT). Typical value = 5,73." },
2816 AttrDef { id: "ExcRQB.lus", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Setpoint (LUS). Typical value = 0,12." },
2817 AttrDef { id: "ExcRQB.mesu", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage input time constant (MESU) (>= 0). Typical value = 0,02." },
2818 AttrDef { id: "ExcRQB.t4m", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input time constant (T4M) (>= 0). Typical value = 5." },
2819 AttrDef { id: "ExcRQB.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead lag time constant (TC) (>= 0). Typical value = 0,02." },
2820 AttrDef { id: "ExcRQB.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead lag time constant (TE) (>= 0). Typical value = 0,22." },
2821 AttrDef { id: "ExcRQB.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant (TF) (>= 0). Typical value = 0,01." },
2822 AttrDef { id: "ExcRQB.ucmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage reference limit (UCMAX) (> ExcRQB.ucmin). Typical value = 1,1." },
2823 AttrDef { id: "ExcRQB.ucmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage reference limit (UCMIN) (< ExcRQB.ucmax). Typical value = 0,9." },
2824 ],
2825 },
2826 ClassDef {
2827 ns: "http://iec.ch/TC57/CIM100#",
2828 local: "ExcSCRX",
2829 qualified: "ExcSCRX",
2830 super_class: Some(161),
2831 concrete: true,
2832 origins: &["DY"],
2833 comment: "Simple excitation system with generic characteristics typical of many excitation systems; intended for use where negative field current could be a problem.",
2834 attrs: &[
2835 AttrDef { id: "ExcSCRX.cswitch", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Power source switch (Cswitch). true = fixed voltage of 1.0 PU false = generator terminal voltage." },
2836 AttrDef { id: "ExcSCRX.emax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum field voltage output (Emax) (> ExcSCRX.emin). Typical value = 5." },
2837 AttrDef { id: "ExcSCRX.emin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum field voltage output (Emin) (< ExcSCRX.emax). Typical value = 0." },
2838 AttrDef { id: "ExcSCRX.k", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (K) (> 0). Typical value = 200." },
2839 AttrDef { id: "ExcSCRX.rcrfd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Ratio of field discharge resistance to field winding resistance ([rc / rfd]). Typical value = 0." },
2840 AttrDef { id: "ExcSCRX.tatb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain reduction ratio of lag-lead element ([Ta / Tb]). The parameter Ta is not defined explicitly. Typical value = 0.1." },
2841 AttrDef { id: "ExcSCRX.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Denominator time constant of lag-lead block (Tb) (>= 0). Typical value = 10." },
2842 AttrDef { id: "ExcSCRX.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of gain block (Te) (> 0). Typical value = 0,02." },
2843 ],
2844 },
2845 ClassDef {
2846 ns: "http://iec.ch/TC57/CIM100#",
2847 local: "ExcSEXS",
2848 qualified: "ExcSEXS",
2849 super_class: Some(161),
2850 concrete: true,
2851 origins: &["DY"],
2852 comment: "Simplified excitation system.",
2853 attrs: &[
2854 AttrDef { id: "ExcSEXS.efdmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field voltage clipping maximum limit (Efdmax) (> ExcSEXS.efdmin). Typical value = 5." },
2855 AttrDef { id: "ExcSEXS.efdmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field voltage clipping minimum limit (Efdmin) (< ExcSEXS.efdmax). Typical value = -5." },
2856 AttrDef { id: "ExcSEXS.emax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum field voltage output (Emax) (> ExcSEXS.emin). Typical value = 5." },
2857 AttrDef { id: "ExcSEXS.emin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum field voltage output (Emin) (< ExcSEXS.emax). Typical value = -5." },
2858 AttrDef { id: "ExcSEXS.k", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (K) (> 0). Typical value = 100." },
2859 AttrDef { id: "ExcSEXS.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PI controller gain (Kc) (> 0 if ExcSEXS.tc > 0). Typical value = 0,08." },
2860 AttrDef { id: "ExcSEXS.tatb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain reduction ratio of lag-lead element ([Ta / Tb]). Typical value = 0,1." },
2861 AttrDef { id: "ExcSEXS.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Denominator time constant of lag-lead block (Tb) (>= 0). Typical value = 10." },
2862 AttrDef { id: "ExcSEXS.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PI controller phase lead time constant (Tc) (>= 0). Typical value = 0." },
2863 AttrDef { id: "ExcSEXS.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of gain block (Te) (> 0). Typical value = 0,05." },
2864 ],
2865 },
2866 ClassDef {
2867 ns: "http://iec.ch/TC57/CIM100#",
2868 local: "ExcSK",
2869 qualified: "ExcSK",
2870 super_class: Some(161),
2871 concrete: true,
2872 origins: &["DY"],
2873 comment: "Slovakian excitation system. UEL and secondary voltage control are included in this model. When this model is used, there cannot be a separate underexcitation limiter or VAr controller model.",
2874 attrs: &[
2875 AttrDef { id: "ExcSK.efdmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field voltage clipping upper level limit (Efdmax) (> ExcSK.efdmin)." },
2876 AttrDef { id: "ExcSK.efdmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field voltage clipping lower level limit (Efdmin) (< ExcSK.efdmax)." },
2877 AttrDef { id: "ExcSK.emax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum field voltage output (Emax) (> ExcSK.emin). Typical value = 20." },
2878 AttrDef { id: "ExcSK.emin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum field voltage output (Emin) (< ExcSK.emax). Typical value = -20." },
2879 AttrDef { id: "ExcSK.k", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (K). Typical value = 1." },
2880 AttrDef { id: "ExcSK.k1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Parameter of underexcitation limit (K1). Typical value = 0,1364." },
2881 AttrDef { id: "ExcSK.k2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Parameter of underexcitation limit (K2). Typical value = -0,3861." },
2882 AttrDef { id: "ExcSK.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PI controller gain (Kc). Typical value = 70." },
2883 AttrDef { id: "ExcSK.kce", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier regulation factor (Kce). Typical value = 0." },
2884 AttrDef { id: "ExcSK.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter internal reactance (Kd). Typical value = 0." },
2885 AttrDef { id: "ExcSK.kgob", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "P controller gain (Kgob). Typical value = 10." },
2886 AttrDef { id: "ExcSK.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PI controller gain (Kp). Typical value = 1." },
2887 AttrDef { id: "ExcSK.kqi", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PI controller gain of integral component (Kqi). Typical value = 0." },
2888 AttrDef { id: "ExcSK.kqob", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rate of rise of the reactive power (Kqob)." },
2889 AttrDef { id: "ExcSK.kqp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PI controller gain (Kqp). Typical value = 0." },
2890 AttrDef { id: "ExcSK.nq", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Deadband of reactive power (nq). Determines the range of sensitivity. Typical value = 0,001." },
2891 AttrDef { id: "ExcSK.qconoff", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Secondary voltage control state (Qc_on_off). true = secondary voltage control is on false = secondary voltage control is off. Typical value = false." },
2892 AttrDef { id: "ExcSK.qz", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Desired value (setpoint) of reactive power, manual setting (Qz)." },
2893 AttrDef { id: "ExcSK.remote", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Selector to apply automatic calculation in secondary controller model (remote). true = automatic calculation is activated false = manual set is active; the use of desired value of reactive power (Qz) is required. Typical value = true." },
2894 AttrDef { id: "ExcSK.sbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ApparentPower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Apparent power of the unit (Sbase) (> 0). Unit = MVA. Typical value = 259." },
2895 AttrDef { id: "ExcSK.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PI controller phase lead time constant (Tc) (>= 0). Typical value = 8." },
2896 AttrDef { id: "ExcSK.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of gain block (Te) (>= 0). Typical value = 0,1." },
2897 AttrDef { id: "ExcSK.ti", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PI controller phase lead time constant (Ti) (>= 0). Typical value = 2." },
2898 AttrDef { id: "ExcSK.tp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Tp) (>= 0). Typical value = 0,1." },
2899 AttrDef { id: "ExcSK.tr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage transducer time constant (Tr) (>= 0). Typical value = 0,01." },
2900 AttrDef { id: "ExcSK.uimax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum error (UImax) (> ExcSK.uimin). Typical value = 10." },
2901 AttrDef { id: "ExcSK.uimin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum error (UImin) (< ExcSK.uimax). Typical value = -10." },
2902 AttrDef { id: "ExcSK.urmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum controller output (URmax) (> ExcSK.urmin). Typical value = 10." },
2903 AttrDef { id: "ExcSK.urmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum controller output (URmin) (< ExcSK.urmax). Typical value = -10." },
2904 AttrDef { id: "ExcSK.vtmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum terminal voltage input (Vtmax) (> ExcSK.vtmin). Determines the range of voltage deadband. Typical value = 1,05." },
2905 AttrDef { id: "ExcSK.vtmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum terminal voltage input (Vtmin) (< ExcSK.vtmax). Determines the range of voltage deadband. Typical value = 0,95." },
2906 AttrDef { id: "ExcSK.yp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum output (Yp). Typical value = 1." },
2907 ],
2908 },
2909 ClassDef {
2910 ns: "http://iec.ch/TC57/CIM100#",
2911 local: "ExcST1A",
2912 qualified: "ExcST1A",
2913 super_class: Some(161),
2914 concrete: true,
2915 origins: &["DY"],
2916 comment: "Modification of an old IEEE ST1A static excitation system without overexcitation limiter (OEL) and underexcitation limiter (UEL).",
2917 attrs: &[
2918 AttrDef { id: "ExcST1A.ilr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter output current limit reference (Ilr). Typical value = 0." },
2919 AttrDef { id: "ExcST1A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (Ka) (> 0). Typical value = 190." },
2920 AttrDef { id: "ExcST1A.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (Kc) (>= 0). Typical value = 0,05." },
2921 AttrDef { id: "ExcST1A.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gains (Kf) (>= 0). Typical value = 0." },
2922 AttrDef { id: "ExcST1A.klr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter output current limiter gain (Klr). Typical value = 0." },
2923 AttrDef { id: "ExcST1A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Ta) (>= 0). Typical value = 0,02." },
2924 AttrDef { id: "ExcST1A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tb) (>= 0). Typical value = 10." },
2925 AttrDef { id: "ExcST1A.tb1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tb1) (>= 0). Typical value = 0." },
2926 AttrDef { id: "ExcST1A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tc) (>= 0). Typical value = 1." },
2927 AttrDef { id: "ExcST1A.tc1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tc1) (>= 0). Typical value = 0." },
2928 AttrDef { id: "ExcST1A.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (Tf) (>= 0). Typical value = 1." },
2929 AttrDef { id: "ExcST1A.vamax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (Vamax) (> 0). Typical value = 999." },
2930 AttrDef { id: "ExcST1A.vamin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (Vamin) (< 0). Typical value = -999." },
2931 AttrDef { id: "ExcST1A.vimax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator input limit (Vimax) (> 0). Typical value = 999." },
2932 AttrDef { id: "ExcST1A.vimin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator input limit (Vimin) (< 0). Typical value = -999." },
2933 AttrDef { id: "ExcST1A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator outputs (Vrmax) (> 0) . Typical value = 7,8." },
2934 AttrDef { id: "ExcST1A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator outputs (Vrmin) (< 0). Typical value = -6,7." },
2935 AttrDef { id: "ExcST1A.xe", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation xfmr effective reactance (Xe). Typical value = 0,04." },
2936 ],
2937 },
2938 ClassDef {
2939 ns: "http://iec.ch/TC57/CIM100#",
2940 local: "ExcST2A",
2941 qualified: "ExcST2A",
2942 super_class: Some(161),
2943 concrete: true,
2944 origins: &["DY"],
2945 comment: "Modified IEEE ST2A static excitation system with another lead-lag block added to match the model defined by WECC.",
2946 attrs: &[
2947 AttrDef { id: "ExcST2A.efdmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum field voltage (Efdmax) (>= 0). Typical value = 99." },
2948 AttrDef { id: "ExcST2A.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator gain (Ka) (> 0). Typical value = 120." },
2949 AttrDef { id: "ExcST2A.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (Kc) (>= 0). Typical value = 1,82." },
2950 AttrDef { id: "ExcST2A.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter constant related to self-excited field (Ke). Typical value = 1." },
2951 AttrDef { id: "ExcST2A.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer gains (kf) (>= 0). Typical value = 0,05." },
2952 AttrDef { id: "ExcST2A.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential circuit gain coefficient (Ki) (>= 0). Typical value = 8." },
2953 AttrDef { id: "ExcST2A.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential circuit gain coefficient (Kp) (>= 0). Typical value = 4,88." },
2954 AttrDef { id: "ExcST2A.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Ta) (> 0). Typical value = 0,15." },
2955 AttrDef { id: "ExcST2A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tb) (>= 0). Typical value = 0." },
2956 AttrDef { id: "ExcST2A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tc) (>= 0). Typical value = 0." },
2957 AttrDef { id: "ExcST2A.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter time constant, integration rate associated with exciter control (Te) (> 0). Typical value = 0,5." },
2958 AttrDef { id: "ExcST2A.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (Tf) (>= 0). Typical value = 0,7." },
2959 AttrDef { id: "ExcST2A.uelin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "UEL input (UELin). true = HV gate false = add to error signal. Typical value = false." },
2960 AttrDef { id: "ExcST2A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator outputs (Vrmax) (> 0). Typical value = 1." },
2961 AttrDef { id: "ExcST2A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator outputs (Vrmin) (< 0). Typical value = -1." },
2962 ],
2963 },
2964 ClassDef {
2965 ns: "http://iec.ch/TC57/CIM100#",
2966 local: "ExcST3A",
2967 qualified: "ExcST3A",
2968 super_class: Some(161),
2969 concrete: true,
2970 origins: &["DY"],
2971 comment: "Modified IEEE ST3A static excitation system with added speed multiplier.",
2972 attrs: &[
2973 AttrDef { id: "ExcST3A.efdmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum AVR output (Efdmax) (>= 0). Typical value = 6,9." },
2974 AttrDef { id: "ExcST3A.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (Kc) (>= 0). Typical value = 1,1." },
2975 AttrDef { id: "ExcST3A.kg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Feedback gain constant of the inner loop field regulator (Kg) (>= 0). Typical value = 1." },
2976 AttrDef { id: "ExcST3A.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential circuit gain coefficient (Ki) (>= 0). Typical value = 4,83." },
2977 AttrDef { id: "ExcST3A.kj", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "AVR gain (Kj) (> 0). Typical value = 200." },
2978 AttrDef { id: "ExcST3A.km", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Forward gain constant of the inner loop field regulator (Km) (> 0). Typical value = 7,04." },
2979 AttrDef { id: "ExcST3A.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential source gain (Kp) (> 0). Typical value = 4,37." },
2980 AttrDef { id: "ExcST3A.ks", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient to allow different usage of the model-speed coefficient (Ks). Typical value = 0." },
2981 AttrDef { id: "ExcST3A.ks1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient to allow different usage of the model-speed coefficient (Ks1). Typical value = 0." },
2982 AttrDef { id: "ExcST3A.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tb) (>= 0). Typical value = 6,67." },
2983 AttrDef { id: "ExcST3A.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Tc) (>= 0). Typical value = 1." },
2984 AttrDef { id: "ExcST3A.thetap", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential circuit phase angle (thetap). Typical value = 20." },
2985 AttrDef { id: "ExcST3A.tm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Forward time constant of inner loop field regulator (Tm) (> 0). Typical value = 1." },
2986 AttrDef { id: "ExcST3A.vbmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum excitation voltage (Vbmax) (> 0). Typical value = 8,63." },
2987 AttrDef { id: "ExcST3A.vgmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum inner loop feedback voltage (Vgmax) (>= 0). Typical value = 6,53." },
2988 AttrDef { id: "ExcST3A.vimax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator input limit (Vimax) (> 0). Typical value = 0,2." },
2989 AttrDef { id: "ExcST3A.vimin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator input limit (Vimin) (< 0). Typical value = -0,2." },
2990 AttrDef { id: "ExcST3A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (Vrmax) (> 0). Typical value = 1." },
2991 AttrDef { id: "ExcST3A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (Vrmin) (< 0). Typical value = -1." },
2992 AttrDef { id: "ExcST3A.xl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactance associated with potential source (Xl) (>= 0). Typical value = 0,09." },
2993 ],
2994 },
2995 ClassDef {
2996 ns: "http://iec.ch/TC57/CIM100#",
2997 local: "ExcST4B",
2998 qualified: "ExcST4B",
2999 super_class: Some(161),
3000 concrete: true,
3001 origins: &["DY"],
3002 comment: "Modified IEEE ST4B static excitation system with maximum inner loop feedback gain Vgmax.",
3003 attrs: &[
3004 AttrDef { id: "ExcST4B.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier loading factor proportional to commutating reactance (Kc) (>= 0). Typical value = 0,113." },
3005 AttrDef { id: "ExcST4B.kg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Feedback gain constant of the inner loop field regulator (Kg) (>= 0). Typical value = 0." },
3006 AttrDef { id: "ExcST4B.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential circuit gain coefficient (Ki) (>= 0). Typical value = 0." },
3007 AttrDef { id: "ExcST4B.kim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator integral gain output (Kim). Typical value = 0." },
3008 AttrDef { id: "ExcST4B.kir", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator integral gain (Kir). Typical value = 10,75." },
3009 AttrDef { id: "ExcST4B.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential circuit gain coefficient (Kp) (> 0). Typical value = 9,3." },
3010 AttrDef { id: "ExcST4B.kpm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator proportional gain output (Kpm). Typical value = 1." },
3011 AttrDef { id: "ExcST4B.kpr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator proportional gain (Kpr). Typical value = 10,75." },
3012 AttrDef { id: "ExcST4B.lvgate", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Selector (LVGate). true = LVGate is part of the block diagram false = LVGate is not part of the block diagram. Typical value = false." },
3013 AttrDef { id: "ExcST4B.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator time constant (Ta) (>= 0). Typical value = 0,02." },
3014 AttrDef { id: "ExcST4B.thetap", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Potential circuit phase angle (thetap). Typical value = 0." },
3015 AttrDef { id: "ExcST4B.uel", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Selector (UEL). true = UEL is part of block diagram false = UEL is not part of block diagram. Typical value = false." },
3016 AttrDef { id: "ExcST4B.vbmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum excitation voltage (Vbmax) (> 0). Typical value = 11,63." },
3017 AttrDef { id: "ExcST4B.vgmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum inner loop feedback voltage (Vgmax) (>= 0). Typical value = 5,8." },
3018 AttrDef { id: "ExcST4B.vmmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum inner loop output (Vmmax) (> ExcST4B.vmmin). Typical value = 99." },
3019 AttrDef { id: "ExcST4B.vmmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum inner loop output (Vmmin) (< ExcST4B.vmmax). Typical value = -99." },
3020 AttrDef { id: "ExcST4B.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (Vrmax) (> 0). Typical value = 1." },
3021 AttrDef { id: "ExcST4B.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (Vrmin) (< 0). Typical value = -0,87." },
3022 AttrDef { id: "ExcST4B.xl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactance associated with potential source (Xl) (>= 0). Typical value = 0,124." },
3023 ],
3024 },
3025 ClassDef {
3026 ns: "http://iec.ch/TC57/CIM100#",
3027 local: "ExcST6B",
3028 qualified: "ExcST6B",
3029 super_class: Some(161),
3030 concrete: true,
3031 origins: &["DY"],
3032 comment: "Modified IEEE ST6B static excitation system with PID controller and optional inner feedback loop.",
3033 attrs: &[
3034 AttrDef { id: "ExcST6B.ilr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter output current limit reference (Ilr) (> 0). Typical value = 4,164." },
3035 AttrDef { id: "ExcST6B.k1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Selector (K1). true = feedback is from Ifd false = feedback is not from Ifd. Typical value = true." },
3036 AttrDef { id: "ExcST6B.kcl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter output current limit adjustment (Kcl) (> 0). Typical value = 1,0577." },
3037 AttrDef { id: "ExcST6B.kff", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pre-control gain constant of the inner loop field regulator (Kff). Typical value = 1." },
3038 AttrDef { id: "ExcST6B.kg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Feedback gain constant of the inner loop field regulator (Kg) (>= 0). Typical value = 1." },
3039 AttrDef { id: "ExcST6B.kia", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator integral gain (Kia) (> 0). Typical value = 45,094." },
3040 AttrDef { id: "ExcST6B.klr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exciter output current limit adjustment (Kcl) (> 0). Typical value = 17,33." },
3041 AttrDef { id: "ExcST6B.km", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Forward gain constant of the inner loop field regulator (Km). Typical value = 1." },
3042 AttrDef { id: "ExcST6B.kpa", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator proportional gain (Kpa) (> 0). Typical value = 18,038." },
3043 AttrDef { id: "ExcST6B.kvd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator derivative gain (Kvd). Typical value = 0." },
3044 AttrDef { id: "ExcST6B.oelin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "ExcST6BOELselectorKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "OEL input selector (OELin). Typical value = noOELinput (corresponds to OELin = 0 on diagram)." },
3045 AttrDef { id: "ExcST6B.tg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Feedback time constant of inner loop field voltage regulator (Tg) (>= 0). Typical value = 0,02." },
3046 AttrDef { id: "ExcST6B.ts", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier firing time constant (Ts) (>= 0). Typical value = 0." },
3047 AttrDef { id: "ExcST6B.tvd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator derivative gain (Tvd) (>= 0). Typical value = 0." },
3048 AttrDef { id: "ExcST6B.vamax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (Vamax) (> 0). Typical value = 4,81." },
3049 AttrDef { id: "ExcST6B.vamin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (Vamin) (< 0). Typical value = -3,85." },
3050 AttrDef { id: "ExcST6B.vilim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Selector (Vilim). true = Vimin-Vimax limiter is active false = Vimin-Vimax limiter is not active. Typical value = true." },
3051 AttrDef { id: "ExcST6B.vimax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator input limit (Vimax) (> ExcST6B.vimin). Typical value = 10." },
3052 AttrDef { id: "ExcST6B.vimin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator input limit (Vimin) (< ExcST6B.vimax). Typical value = -10." },
3053 AttrDef { id: "ExcST6B.vmult", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Selector (vmult). true = multiply regulator output by terminal voltage false = do not multiply regulator output by terminal voltage. Typical value = true." },
3054 AttrDef { id: "ExcST6B.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (Vrmax) (> 0). Typical value = 4,81." },
3055 AttrDef { id: "ExcST6B.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (Vrmin) (< 0). Typical value = -3,85." },
3056 AttrDef { id: "ExcST6B.xc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation source reactance (Xc). Typical value = 0,05." },
3057 ],
3058 },
3059 ClassDef {
3060 ns: "http://iec.ch/TC57/CIM100#",
3061 local: "ExcST7B",
3062 qualified: "ExcST7B",
3063 super_class: Some(161),
3064 concrete: true,
3065 origins: &["DY"],
3066 comment: "Modified IEEE ST7B static excitation system without stator current limiter (SCL) and current compensator (DROOP) inputs.",
3067 attrs: &[
3068 AttrDef { id: "ExcST7B.kh", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High-value gate feedback gain (Kh) (>= 0). Typical value = 1." },
3069 AttrDef { id: "ExcST7B.kia", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator integral gain (Kia) (>= 0). Typical value = 1." },
3070 AttrDef { id: "ExcST7B.kl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low-value gate feedback gain (Kl) (>= 0). Typical value = 1." },
3071 AttrDef { id: "ExcST7B.kpa", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator proportional gain (Kpa) (> 0). Typical value = 40." },
3072 AttrDef { id: "ExcST7B.oelin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "ExcST7BOELselectorKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "OEL input selector (OELin). Typical value = noOELinput." },
3073 AttrDef { id: "ExcST7B.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Regulator lag time constant (Tb) (>= 0). Typical value = 1." },
3074 AttrDef { id: "ExcST7B.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Regulator lead time constant (Tc) (>= 0). Typical value = 1." },
3075 AttrDef { id: "ExcST7B.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation control system stabilizer time constant (Tf) (>= 0). Typical value = 1." },
3076 AttrDef { id: "ExcST7B.tg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Feedback time constant of inner loop field voltage regulator (Tg) (>= 0). Typical value = 1." },
3077 AttrDef { id: "ExcST7B.tia", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Feedback time constant (Tia) (>= 0). Typical value = 3." },
3078 AttrDef { id: "ExcST7B.ts", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rectifier firing time constant (Ts) (>= 0). Typical value = 0." },
3079 AttrDef { id: "ExcST7B.uelin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "ExcST7BUELselectorKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "UEL input selector (UELin). Typical value = noUELinput." },
3080 AttrDef { id: "ExcST7B.vmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage reference signal (Vmax) (> 0 and > ExcST7B.vmin)). Typical value = 1,1." },
3081 AttrDef { id: "ExcST7B.vmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage reference signal (Vmin) (> 0 and < ExcST7B.vmax). Typical value = 0,9." },
3082 AttrDef { id: "ExcST7B.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage regulator output (Vrmax) (> 0). Typical value = 5." },
3083 AttrDef { id: "ExcST7B.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage regulator output (Vrmin) (< 0). Typical value = -4,5." },
3084 ],
3085 },
3086 ClassDef {
3087 ns: "http://iec.ch/TC57/CIM100#",
3088 local: "ExcitationSystemDynamics",
3089 qualified: "ExcitationSystemDynamics",
3090 super_class: Some(91),
3091 concrete: false,
3092 origins: &["DY"],
3093 comment: "Excitation system function block whose behaviour is described by reference to a standard model or by definition of a user-defined model.",
3094 attrs: &[
3095 AttrDef { id: "ExcitationSystemDynamics.DiscontinuousExcitationControlDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DiscontinuousExcitationControlDynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Discontinuous excitation control model associated with this excitation system model." },
3096 AttrDef { id: "ExcitationSystemDynamics.OverexcitationLimiterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "OverexcitationLimiterDynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Overexcitation limiter model associated with this excitation system model." },
3097 AttrDef { id: "ExcitationSystemDynamics.PFVArControllerType1Dynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PFVArControllerType1Dynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Power factor or VAr controller type 1 model associated with this excitation system model." },
3098 AttrDef { id: "ExcitationSystemDynamics.PFVArControllerType2Dynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PFVArControllerType2Dynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Power factor or VAr controller type 2 model associated with this excitation system model." },
3099 AttrDef { id: "ExcitationSystemDynamics.PowerSystemStabilizerDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PowerSystemStabilizerDynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Power system stabilizer model associated with this excitation system model." },
3100 AttrDef { id: "ExcitationSystemDynamics.SynchronousMachineDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SynchronousMachineDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Synchronous machine model with which this excitation system model is associated." },
3101 AttrDef { id: "ExcitationSystemDynamics.UnderexcitationLimiterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "UnderexcitationLimiterDynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Undrexcitation limiter model associated with this excitation system model." },
3102 AttrDef { id: "ExcitationSystemDynamics.VoltageCompensatorDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "VoltageCompensatorDynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Voltage compensator model associated with this excitation system model." },
3103 ],
3104 },
3105 ClassDef {
3106 ns: "http://iec.ch/TC57/CIM100#",
3107 local: "ExcitationSystemUserDefined",
3108 qualified: "ExcitationSystemUserDefined",
3109 super_class: Some(161),
3110 concrete: true,
3111 origins: &["DY"],
3112 comment: "Excitation system function block whose dynamic behaviour is described by a user-defined model.",
3113 attrs: &[
3114 AttrDef { id: "ExcitationSystemUserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
3115 AttrDef { id: "ExcitationSystemUserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
3116 ],
3117 },
3118 ClassDef {
3119 ns: "http://iec.ch/TC57/CIM100#",
3120 local: "ExternalNetworkInjection",
3121 qualified: "ExternalNetworkInjection",
3122 super_class: Some(315),
3123 concrete: true,
3124 origins: &["EQ", "SC", "SSH"],
3125 comment: "This class represents the external network and it is used for IEC 60909 calculations.",
3126 attrs: &[
3127 AttrDef { id: "ExternalNetworkInjection.governorSCD", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePowerPerFrequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Power Frequency Bias. This is the change in power injection divided by the change in frequency and negated. A positive value of the power frequency bias provides additional power injection upon a drop in frequency." },
3128 AttrDef { id: "ExternalNetworkInjection.ikSecond", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["SC"], comment: "Indicates whether initial symmetrical short-circuit current and power have been calculated according to IEC (Ik'). Used only if short circuit calculations are done according to superposition method." },
3129 AttrDef { id: "ExternalNetworkInjection.maxInitialSymShCCurrent", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "CurrentFlow", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Maximum initial symmetrical short-circuit currents (Ik' max) in A (Ik' = Sk'/(SQRT(3) Un)). Used for short circuit data exchange according to IEC 60909." },
3130 AttrDef { id: "ExternalNetworkInjection.maxP", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Maximum active power of the injection." },
3131 AttrDef { id: "ExternalNetworkInjection.maxQ", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Maximum reactive power limit. It is used for modelling of infeed for load flow exchange and not for short circuit modelling." },
3132 AttrDef { id: "ExternalNetworkInjection.maxR0ToX0Ratio", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Maximum ratio of zero sequence resistance of Network Feeder to its zero sequence reactance (R(0)/X(0) max). Used for short circuit data exchange according to IEC 60909." },
3133 AttrDef { id: "ExternalNetworkInjection.maxR1ToX1Ratio", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Maximum ratio of positive sequence resistance of Network Feeder to its positive sequence reactance (R(1)/X(1) max). Used for short circuit data exchange according to IEC 60909." },
3134 AttrDef { id: "ExternalNetworkInjection.maxZ0ToZ1Ratio", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Maximum ratio of zero sequence impedance to its positive sequence impedance (Z(0)/Z(1) max). Used for short circuit data exchange according to IEC 60909." },
3135 AttrDef { id: "ExternalNetworkInjection.minInitialSymShCCurrent", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "CurrentFlow", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Minimum initial symmetrical short-circuit currents (Ik' min) in A (Ik' = Sk'/(SQRT(3) Un)). Used for short circuit data exchange according to IEC 60909." },
3136 AttrDef { id: "ExternalNetworkInjection.minP", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Minimum active power of the injection." },
3137 AttrDef { id: "ExternalNetworkInjection.minQ", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Minimum reactive power limit. It is used for modelling of infeed for load flow exchange and not for short circuit modelling." },
3138 AttrDef { id: "ExternalNetworkInjection.minR0ToX0Ratio", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Indicates whether initial symmetrical short-circuit current and power have been calculated according to IEC (Ik'). Used for short circuit data exchange according to IEC 6090." },
3139 AttrDef { id: "ExternalNetworkInjection.minR1ToX1Ratio", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Minimum ratio of positive sequence resistance of Network Feeder to its positive sequence reactance (R(1)/X(1) min). Used for short circuit data exchange according to IEC 60909." },
3140 AttrDef { id: "ExternalNetworkInjection.minZ0ToZ1Ratio", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Minimum ratio of zero sequence impedance to its positive sequence impedance (Z(0)/Z(1) min). Used for short circuit data exchange according to IEC 60909." },
3141 AttrDef { id: "ExternalNetworkInjection.p", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Active power injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for steady state solutions." },
3142 AttrDef { id: "ExternalNetworkInjection.q", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Reactive power injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for steady state solutions." },
3143 AttrDef { id: "ExternalNetworkInjection.referencePriority", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["SSH"], comment: "Priority of unit for use as powerflow voltage phase angle reference bus selection. 0 = don t care (default) 1 = highest priority. 2 is less than 1 and so on." },
3144 AttrDef { id: "ExternalNetworkInjection.voltageFactor", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Voltage factor in pu, which was used to calculate short-circuit current Ik' and power Sk'. Used only if short circuit calculations are done according to superposition method." },
3145 ],
3146 },
3147 ClassDef {
3148 ns: "http://iec.ch/TC57/CIM100#",
3149 local: "FaultIndicator",
3150 qualified: "FaultIndicator",
3151 super_class: Some(21),
3152 concrete: true,
3153 origins: &["EQ"],
3154 comment: "A FaultIndicator is typically only an indicator (which may or may not be remotely monitored), and not a piece of equipment that actually initiates a protection event. It is used for FLISR (Fault Location, Isolation and Restoration) purposes, assisting with the dispatch of crews to 'most likely' part of the network (i.e. assists with determining circuit section where the fault most likely happened).",
3155 attrs: &[],
3156 },
3157 ClassDef {
3158 ns: "http://iec.ch/TC57/CIM100#",
3159 local: "FossilFuel",
3160 qualified: "FossilFuel",
3161 super_class: Some(213),
3162 concrete: true,
3163 origins: &["EQ"],
3164 comment: "The fossil fuel consumed by the non-nuclear thermal generating unit. For example, coal, oil, gas, etc. These are the specific fuels that the generating unit can consume.",
3165 attrs: &[
3166 AttrDef { id: "FossilFuel.ThermalGeneratingUnit", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ThermalGeneratingUnit", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "A thermal generating unit may have one or more fossil fuels." },
3167 AttrDef { id: "FossilFuel.fossilFuelType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "FuelType", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "The type of fossil fuel, such as coal, oil, or gas." },
3168 ],
3169 },
3170 ClassDef {
3171 ns: "http://iec.ch/TC57/61970-552/ModelDescription/1#",
3172 local: "FullModel",
3173 qualified: "FullModel",
3174 super_class: Some(240),
3175 concrete: true,
3176 origins: &["FH"],
3177 comment: "It represents the full model header and its contents is described by the Model class.",
3178 attrs: &[],
3179 },
3180 ClassDef {
3181 ns: "http://iec.ch/TC57/CIM100#",
3182 local: "Fuse",
3183 qualified: "Fuse",
3184 super_class: Some(353),
3185 concrete: true,
3186 origins: &["EQ", "SSH"],
3187 comment: "An overcurrent protective device with a circuit opening fusible part that is heated and severed by the passage of overcurrent through it. A fuse is considered a switching device because it breaks current.",
3188 attrs: &[],
3189 },
3190 ClassDef {
3191 ns: "http://iec.ch/TC57/CIM100#",
3192 local: "GenICompensationForGenJ",
3193 qualified: "GenICompensationForGenJ",
3194 super_class: Some(213),
3195 concrete: true,
3196 origins: &["DY"],
3197 comment: "Resistive and reactive components of compensation for generator associated with IEEE type 2 voltage compensator for current flow out of another generator in the interconnection.",
3198 attrs: &[
3199 AttrDef { id: "GenICompensationForGenJ.SynchronousMachineDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SynchronousMachineDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Standard synchronous machine out of which current flow is being compensated for." },
3200 AttrDef { id: "GenICompensationForGenJ.VcompIEEEType2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "VCompIEEEType2", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "The standard IEEE type 2 voltage compensator of this compensation." },
3201 AttrDef { id: "GenICompensationForGenJ.rcij", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Resistive component of compensation of generator associated with this IEEE type 2 voltage compensator for current flow out of another generator (Rcij)." },
3202 AttrDef { id: "GenICompensationForGenJ.xcij", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive component of compensation of generator associated with this IEEE type 2 voltage compensator for current flow out of another generator (Xcij)." },
3203 ],
3204 },
3205 ClassDef {
3206 ns: "http://iec.ch/TC57/CIM100#",
3207 local: "GeneratingUnit",
3208 qualified: "GeneratingUnit",
3209 super_class: Some(98),
3210 concrete: true,
3211 origins: &["EQ", "SSH"],
3212 comment: "A single or set of synchronous machines for converting mechanical power into alternating-current power. For example, individual machines within a set may be defined for scheduling purposes while a single control signal is derived for the set. In this case there would be a GeneratingUnit for each member of the set and an additional GeneratingUnit corresponding to the set.",
3213 attrs: &[
3214 AttrDef { id: "GeneratingUnit.ControlAreaGeneratingUnit", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ControlAreaGeneratingUnit", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "ControlArea specifications for this generating unit." },
3215 AttrDef { id: "GeneratingUnit.GrossToNetActivePowerCurves", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "GrossToNetActivePowerCurve", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "A generating unit may have a gross active power to net active power curve, describing the losses and auxiliary power requirements of the unit." },
3216 AttrDef { id: "GeneratingUnit.RotatingMachine", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RotatingMachine", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "A synchronous machine may operate as a generator and as such becomes a member of a generating unit." },
3217 AttrDef { id: "GeneratingUnit.genControlSource", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "GeneratorControlSource", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "The source of controls for a generating unit. Defines the control status of the generating unit." },
3218 AttrDef { id: "GeneratingUnit.governorSCD", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PerCent", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Governor Speed Changer Droop. This is the change in generator power output divided by the change in frequency normalized by the nominal power of the generator and the nominal frequency and expressed in percent and negated. A positive value of speed change droop provides additional generator output upon a drop in frequency." },
3219 AttrDef { id: "GeneratingUnit.longPF", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Generating unit long term economic participation factor." },
3220 AttrDef { id: "GeneratingUnit.maxOperatingP", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "This is the maximum operating active power limit the dispatcher can enter for this unit." },
3221 AttrDef { id: "GeneratingUnit.maximumAllowableSpinningReserve", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Maximum allowable spinning reserve. Spinning reserve will never be considered greater than this value regardless of the current operating point." },
3222 AttrDef { id: "GeneratingUnit.minOperatingP", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "This is the minimum operating active power limit the dispatcher can enter for this unit." },
3223 AttrDef { id: "GeneratingUnit.nominalP", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The nominal power of the generating unit. Used to give precise meaning to percentage based attributes such as the governor speed change droop (governorSCD attribute). The attribute shall be a positive value equal to or less than RotatingMachine.ratedS." },
3224 AttrDef { id: "GeneratingUnit.normalPF", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Generating unit economic participation factor. The sum of the participation factors across generating units does not have to sum to one. It is used for representing distributed slack participation factor. The attribute shall be a positive value or zero." },
3225 AttrDef { id: "GeneratingUnit.ratedGrossMaxP", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The unit's gross rated maximum capacity (book value). The attribute shall be a positive value." },
3226 AttrDef { id: "GeneratingUnit.ratedGrossMinP", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The gross rated minimum generation level which the unit can safely operate at while delivering power to the transmission grid. The attribute shall be a positive value." },
3227 AttrDef { id: "GeneratingUnit.ratedNetMaxP", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The net rated maximum capacity determined by subtracting the auxiliary power used to operate the internal plant machinery from the rated gross maximum capacity. The attribute shall be a positive value." },
3228 AttrDef { id: "GeneratingUnit.shortPF", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Generating unit short term economic participation factor." },
3229 AttrDef { id: "GeneratingUnit.startupCost", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Money", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The initial startup cost incurred for each start of the GeneratingUnit." },
3230 AttrDef { id: "GeneratingUnit.startupTime", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Time it takes to get the unit on-line, from the time that the prime mover mechanical power is applied." },
3231 AttrDef { id: "GeneratingUnit.totalEfficiency", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PerCent", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The efficiency of the unit in converting the fuel into electrical energy." },
3232 AttrDef { id: "GeneratingUnit.variableCost", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Money", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The variable cost component of production per unit of ActivePower." },
3233 ],
3234 },
3235 ClassDef {
3236 ns: "http://iec.ch/TC57/CIM100#",
3237 local: "GeographicalRegion",
3238 qualified: "GeographicalRegion",
3239 super_class: Some(213),
3240 concrete: true,
3241 origins: &["EQ", "EQBD"],
3242 comment: "A geographical region of a power system network model.",
3243 attrs: &[
3244 AttrDef { id: "GeographicalRegion.Regions", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SubGeographicalRegion", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "All sub-geographical regions within this geographical region." },
3245 ],
3246 },
3247 ClassDef {
3248 ns: "http://iec.ch/TC57/CIM100#",
3249 local: "GovCT1",
3250 qualified: "GovCT1",
3251 super_class: Some(375),
3252 concrete: true,
3253 origins: &["DY"],
3254 comment: "General model for any prime mover with a PID governor, used primarily for combustion turbine and combined cycle units. This model can be used to represent a variety of prime movers controlled by PID governors. It is suitable, for example, for the representation of: gas turbine and single shaft combined cycle turbines diesel engines with modern electronic or digital governors steam turbines where steam is supplied from a large boiler drum or a large header whose pressure is substantially constant over the period under study simple hydro turbines in dam configurations where the water column length is short and water inertia effects are minimal. Additional information on this model is available in the 2012 IEEE report, Dynamic Models for Turbine-Governors in Power System Studies, 3.1.2.3 pages 3-4 (GGOV1).",
3255 attrs: &[
3256 AttrDef { id: "GovCT1.aset", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Acceleration limiter setpoint (Aset). Unit = PU / s. Typical value = 0,01." },
3257 AttrDef { id: "GovCT1.db", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Speed governor deadband in PU speed (db). In the majority of applications, it is recommended that this value be set to zero. Typical value = 0." },
3258 AttrDef { id: "GovCT1.dm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Speed sensitivity coefficient (Dm). Dm can represent either the variation of the engine power with the shaft speed or the variation of maximum power capability with shaft speed. If it is positive it describes the falling slope of the engine speed verses power characteristic as speed increases. A slightly falling characteristic is typical for reciprocating engines and some aero-derivative turbines. If it is negative the engine power is assumed to be unaffected by the shaft speed, but the maximum permissible fuel flow is taken to fall with falling shaft speed. This is characteristic of single-shaft industrial turbines due to exhaust temperature limits. Typical value = 0." },
3259 AttrDef { id: "GovCT1.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Acceleration limiter gain (Ka). Typical value = 10." },
3260 AttrDef { id: "GovCT1.kdgov", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor derivative gain (Kdgov). Typical value = 0." },
3261 AttrDef { id: "GovCT1.kigov", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor integral gain (Kigov). Typical value = 2." },
3262 AttrDef { id: "GovCT1.kiload", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Load limiter integral gain for PI controller (Kiload). Typical value = 0,67." },
3263 AttrDef { id: "GovCT1.kimw", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power controller (reset) gain (Kimw). The default value of 0,01 corresponds to a reset time of 100 s. A value of 0,001 corresponds to a relatively slow-acting load controller. Typical value = 0,01." },
3264 AttrDef { id: "GovCT1.kpgov", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor proportional gain (Kpgov). Typical value = 10." },
3265 AttrDef { id: "GovCT1.kpload", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Load limiter proportional gain for PI controller (Kpload). Typical value = 2." },
3266 AttrDef { id: "GovCT1.kturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine gain (Kturb) (> 0). Typical value = 1,5." },
3267 AttrDef { id: "GovCT1.ldref", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Load limiter reference value (Ldref). Typical value = 1." },
3268 AttrDef { id: "GovCT1.maxerr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum value for speed error signal (maxerr) (> GovCT1.minerr). Typical value = 0,05." },
3269 AttrDef { id: "GovCT1.minerr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum value for speed error signal (minerr) (< GovCT1.maxerr). Typical value = -0,05." },
3270 AttrDef { id: "GovCT1.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
3271 AttrDef { id: "GovCT1.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Permanent droop (R). Typical value = 0,04." },
3272 AttrDef { id: "GovCT1.rclose", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum valve closing rate (Rclose). Unit = PU / s. Typical value = -0,1." },
3273 AttrDef { id: "GovCT1.rdown", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum rate of load limit decrease (Rdown). Typical value = -99." },
3274 AttrDef { id: "GovCT1.ropen", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum valve opening rate (Ropen). Unit = PU / s. Typical value = 0.10." },
3275 AttrDef { id: "GovCT1.rselect", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "DroopSignalFeedbackKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Feedback signal for droop (Rselect). Typical value = electricalPower." },
3276 AttrDef { id: "GovCT1.rup", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum rate of load limit increase (Rup). Typical value = 99." },
3277 AttrDef { id: "GovCT1.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Acceleration limiter time constant (Ta) (> 0). Typical value = 0,1." },
3278 AttrDef { id: "GovCT1.tact", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Actuator time constant (Tact) (>= 0). Typical value = 0,5." },
3279 AttrDef { id: "GovCT1.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine lag time constant (Tb) (> 0). Typical value = 0,5." },
3280 AttrDef { id: "GovCT1.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine lead time constant (Tc) (>= 0). Typical value = 0." },
3281 AttrDef { id: "GovCT1.tdgov", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor derivative controller time constant (Tdgov) (>= 0). Typical value = 1." },
3282 AttrDef { id: "GovCT1.teng", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Transport time delay for diesel engine used in representing diesel engines where there is a small but measurable transport delay between a change in fuel flow setting and the development of torque (Teng) (>= 0). Teng should be zero in all but special cases where this transport delay is of particular concern. Typical value = 0." },
3283 AttrDef { id: "GovCT1.tfload", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Load-limiter time constant (Tfload) (> 0). Typical value = 3." },
3284 AttrDef { id: "GovCT1.tpelec", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Electrical power transducer time constant (Tpelec) (> 0). Typical value = 1." },
3285 AttrDef { id: "GovCT1.tsa", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Temperature detection lead time constant (Tsa) (>= 0). Typical value = 4." },
3286 AttrDef { id: "GovCT1.tsb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Temperature detection lag time constant (Tsb) (>= 0). Typical value = 5." },
3287 AttrDef { id: "GovCT1.vmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum valve position limit (Vmax) (> GovCT1.vmin). Typical value = 1." },
3288 AttrDef { id: "GovCT1.vmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum valve position limit (Vmin) (< GovCT1.vmax). Typical value = 0,15." },
3289 AttrDef { id: "GovCT1.wfnl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "No load fuel flow (Wfnl). Typical value = 0,2." },
3290 AttrDef { id: "GovCT1.wfspd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Switch for fuel source characteristic to recognize that fuel flow, for a given fuel valve stroke, can be proportional to engine speed (Wfspd). true = fuel flow proportional to speed (for some gas turbines and diesel engines with positive displacement fuel injectors) false = fuel control system keeps fuel flow independent of engine speed. Typical value = true." },
3291 ],
3292 },
3293 ClassDef {
3294 ns: "http://iec.ch/TC57/CIM100#",
3295 local: "GovCT2",
3296 qualified: "GovCT2",
3297 super_class: Some(375),
3298 concrete: true,
3299 origins: &["DY"],
3300 comment: "General governor with frequency-dependent fuel flow limit. This model is a modification of the GovCT1 model in order to represent the frequency-dependent fuel flow limit of a specific gas turbine manufacturer.",
3301 attrs: &[
3302 AttrDef { id: "GovCT2.aset", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Acceleration limiter setpoint (Aset). Unit = PU / s. Typical value = 10." },
3303 AttrDef { id: "GovCT2.db", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Speed governor deadband in PU speed (db). In the majority of applications, it is recommended that this value be set to zero. Typical value = 0." },
3304 AttrDef { id: "GovCT2.dm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Speed sensitivity coefficient (Dm). Dm can represent either the variation of the engine power with the shaft speed or the variation of maximum power capability with shaft speed. If it is positive it describes the falling slope of the engine speed verses power characteristic as speed increases. A slightly falling characteristic is typical for reciprocating engines and some aero-derivative turbines. If it is negative the engine power is assumed to be unaffected by the shaft speed, but the maximum permissible fuel flow is taken to fall with falling shaft speed. This is characteristic of single-shaft industrial turbines due to exhaust temperature limits. Typical value = 0." },
3305 AttrDef { id: "GovCT2.flim1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency threshold 1 (Flim1). Unit = Hz. Typical value = 59." },
3306 AttrDef { id: "GovCT2.flim10", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency threshold 10 (Flim10). Unit = Hz. Typical value = 0." },
3307 AttrDef { id: "GovCT2.flim2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency threshold 2 (Flim2). Unit = Hz. Typical value = 0." },
3308 AttrDef { id: "GovCT2.flim3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency threshold 3 (Flim3). Unit = Hz. Typical value = 0." },
3309 AttrDef { id: "GovCT2.flim4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency threshold 4 (Flim4). Unit = Hz. Typical value = 0." },
3310 AttrDef { id: "GovCT2.flim5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency threshold 5 (Flim5). Unit = Hz. Typical value = 0." },
3311 AttrDef { id: "GovCT2.flim6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency threshold 6 (Flim6). Unit = Hz. Typical value = 0." },
3312 AttrDef { id: "GovCT2.flim7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency threshold 7 (Flim7). Unit = Hz. Typical value = 0." },
3313 AttrDef { id: "GovCT2.flim8", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency threshold 8 (Flim8). Unit = Hz. Typical value = 0." },
3314 AttrDef { id: "GovCT2.flim9", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency threshold 9 (Flim9). Unit = Hz. Typical value = 0." },
3315 AttrDef { id: "GovCT2.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Acceleration limiter gain (Ka). Typical value = 10." },
3316 AttrDef { id: "GovCT2.kdgov", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor derivative gain (Kdgov). Typical value = 0." },
3317 AttrDef { id: "GovCT2.kigov", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor integral gain (Kigov). Typical value = 0,45." },
3318 AttrDef { id: "GovCT2.kiload", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Load limiter integral gain for PI controller (Kiload). Typical value = 1." },
3319 AttrDef { id: "GovCT2.kimw", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power controller (reset) gain (Kimw). The default value of 0,01 corresponds to a reset time of 100 seconds. A value of 0,001 corresponds to a relatively slow-acting load controller. Typical value = 0." },
3320 AttrDef { id: "GovCT2.kpgov", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor proportional gain (Kpgov). Typical value = 4." },
3321 AttrDef { id: "GovCT2.kpload", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Load limiter proportional gain for PI controller (Kpload). Typical value = 1." },
3322 AttrDef { id: "GovCT2.kturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine gain (Kturb). Typical value = 1,9168." },
3323 AttrDef { id: "GovCT2.ldref", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Load limiter reference value (Ldref). Typical value = 1." },
3324 AttrDef { id: "GovCT2.maxerr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum value for speed error signal (Maxerr) (> GovCT2.minerr). Typical value = 1." },
3325 AttrDef { id: "GovCT2.minerr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum value for speed error signal (Minerr) (< GovCT2.maxerr). Typical value = -1." },
3326 AttrDef { id: "GovCT2.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
3327 AttrDef { id: "GovCT2.plim1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power limit 1 (Plim1). Typical value = 0,8325." },
3328 AttrDef { id: "GovCT2.plim10", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power limit 10 (Plim10). Typical value = 0." },
3329 AttrDef { id: "GovCT2.plim2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power limit 2 (Plim2). Typical value = 0." },
3330 AttrDef { id: "GovCT2.plim3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power limit 3 (Plim3). Typical value = 0." },
3331 AttrDef { id: "GovCT2.plim4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power limit 4 (Plim4). Typical value = 0." },
3332 AttrDef { id: "GovCT2.plim5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power limit 5 (Plim5). Typical value = 0." },
3333 AttrDef { id: "GovCT2.plim6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power limit 6 (Plim6). Typical value = 0." },
3334 AttrDef { id: "GovCT2.plim7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power limit 7 (Plim7). Typical value = 0." },
3335 AttrDef { id: "GovCT2.plim8", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power limit 8 (Plim8). Typical value = 0." },
3336 AttrDef { id: "GovCT2.plim9", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power Limit 9 (Plim9). Typical value = 0." },
3337 AttrDef { id: "GovCT2.prate", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Ramp rate for frequency-dependent power limit (Prate). Typical value = 0,017." },
3338 AttrDef { id: "GovCT2.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Permanent droop (R). Typical value = 0,05." },
3339 AttrDef { id: "GovCT2.rclose", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum valve closing rate (Rclose). Unit = PU / s. Typical value = -99." },
3340 AttrDef { id: "GovCT2.rdown", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum rate of load limit decrease (Rdown). Typical value = -99." },
3341 AttrDef { id: "GovCT2.ropen", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum valve opening rate (Ropen). Unit = PU / s. Typical value = 99." },
3342 AttrDef { id: "GovCT2.rselect", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "DroopSignalFeedbackKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Feedback signal for droop (Rselect). Typical value = electricalPower." },
3343 AttrDef { id: "GovCT2.rup", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum rate of load limit increase (Rup). Typical value = 99." },
3344 AttrDef { id: "GovCT2.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Acceleration limiter time constant (Ta) (>= 0). Typical value = 1." },
3345 AttrDef { id: "GovCT2.tact", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Actuator time constant (Tact) (>= 0). Typical value = 0,4." },
3346 AttrDef { id: "GovCT2.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine lag time constant (Tb) (>= 0). Typical value = 0,1." },
3347 AttrDef { id: "GovCT2.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine lead time constant (Tc) (>= 0). Typical value = 0." },
3348 AttrDef { id: "GovCT2.tdgov", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor derivative controller time constant (Tdgov) (>= 0). Typical value = 1." },
3349 AttrDef { id: "GovCT2.teng", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Transport time delay for diesel engine used in representing diesel engines where there is a small but measurable transport delay between a change in fuel flow setting and the development of torque (Teng) (>= 0). Teng should be zero in all but special cases where this transport delay is of particular concern. Typical value = 0." },
3350 AttrDef { id: "GovCT2.tfload", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Load limiter time constant (Tfload) (>= 0). Typical value = 3." },
3351 AttrDef { id: "GovCT2.tpelec", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Electrical power transducer time constant (Tpelec) (>= 0). Typical value = 2,5." },
3352 AttrDef { id: "GovCT2.tsa", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Temperature detection lead time constant (Tsa) (>= 0). Typical value = 0." },
3353 AttrDef { id: "GovCT2.tsb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Temperature detection lag time constant (Tsb) (>= 0). Typical value = 50." },
3354 AttrDef { id: "GovCT2.vmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum valve position limit (Vmax) (> GovCT2.vmin). Typical value = 1." },
3355 AttrDef { id: "GovCT2.vmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum valve position limit (Vmin) (< GovCT2.vmax). Typical value = 0,175." },
3356 AttrDef { id: "GovCT2.wfnl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "No load fuel flow (Wfnl). Typical value = 0,187." },
3357 AttrDef { id: "GovCT2.wfspd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Switch for fuel source characteristic to recognize that fuel flow, for a given fuel valve stroke, can be proportional to engine speed (Wfspd). true = fuel flow proportional to speed (for some gas turbines and diesel engines with positive displacement fuel injectors) false = fuel control system keeps fuel flow independent of engine speed. Typical value = false." },
3358 ],
3359 },
3360 ClassDef {
3361 ns: "http://iec.ch/TC57/CIM100#",
3362 local: "GovGAST",
3363 qualified: "GovGAST",
3364 super_class: Some(375),
3365 concrete: true,
3366 origins: &["DY"],
3367 comment: "Single shaft gas turbine.",
3368 attrs: &[
3369 AttrDef { id: "GovGAST.at", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Ambient temperature load limit (Load Limit). Typical value = 1." },
3370 AttrDef { id: "GovGAST.dturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine damping factor (Dturb). Typical value = 0,18." },
3371 AttrDef { id: "GovGAST.kt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Temperature limiter gain (Kt). Typical value = 3." },
3372 AttrDef { id: "GovGAST.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
3373 AttrDef { id: "GovGAST.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Permanent droop (R) (>0). Typical value = 0,04." },
3374 AttrDef { id: "GovGAST.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor mechanism time constant (T1) (>= 0). T1 represents the natural valve positioning time constant of the governor for small disturbances, as seen when rate limiting is not in effect. Typical value = 0,5." },
3375 AttrDef { id: "GovGAST.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine power time constant (T2) (>= 0). T2 represents delay due to internal energy storage of the gas turbine engine. T2 can be used to give a rough approximation to the delay associated with acceleration of the compressor spool of a multi-shaft engine, or with the compressibility of gas in the plenum of a free power turbine of an aero-derivative unit, for example. Typical value = 0,5." },
3376 AttrDef { id: "GovGAST.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine exhaust temperature time constant (T3) (>= 0). Typical value = 3." },
3377 AttrDef { id: "GovGAST.vmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum turbine power, PU of MWbase (Vmax) (> GovGAST.vmin). Typical value = 1." },
3378 AttrDef { id: "GovGAST.vmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum turbine power, PU of MWbase (Vmin) (< GovGAST.vmax). Typical value = 0." },
3379 ],
3380 },
3381 ClassDef {
3382 ns: "http://iec.ch/TC57/CIM100#",
3383 local: "GovGAST1",
3384 qualified: "GovGAST1",
3385 super_class: Some(375),
3386 concrete: true,
3387 origins: &["DY"],
3388 comment: "Modified single shaft gas turbine.",
3389 attrs: &[
3390 AttrDef { id: "GovGAST1.a", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine power time constant numerator scale factor (a). Typical value = 0,8." },
3391 AttrDef { id: "GovGAST1.b", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine power time constant denominator scale factor (b) (>0). Typical value = 1." },
3392 AttrDef { id: "GovGAST1.db1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intentional dead-band width (db1). Unit = Hz. Typical value = 0." },
3393 AttrDef { id: "GovGAST1.db2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Unintentional dead-band (db2). Unit = MW. Typical value = 0." },
3394 AttrDef { id: "GovGAST1.eps", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intentional db hysteresis (eps). Unit = Hz. Typical value = 0." },
3395 AttrDef { id: "GovGAST1.fidle", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fuel flow at zero power output (Fidle). Typical value = 0,18." },
3396 AttrDef { id: "GovGAST1.gv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 1, PU gv (Gv1). Typical value = 0." },
3397 AttrDef { id: "GovGAST1.gv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 2,PU gv (Gv2). Typical value = 0." },
3398 AttrDef { id: "GovGAST1.gv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 3, PU gv (Gv3). Typical value = 0." },
3399 AttrDef { id: "GovGAST1.gv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 4, PU gv (Gv4). Typical value = 0." },
3400 AttrDef { id: "GovGAST1.gv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 5, PU gv (Gv5). Typical value = 0." },
3401 AttrDef { id: "GovGAST1.gv6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 6, PU gv (Gv6). Typical value = 0." },
3402 AttrDef { id: "GovGAST1.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor gain (Ka). Typical value = 0." },
3403 AttrDef { id: "GovGAST1.kt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Temperature limiter gain (Kt). Typical value = 3." },
3404 AttrDef { id: "GovGAST1.lmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Ambient temperature load limit (Lmax). Lmax is the turbine power output corresponding to the limiting exhaust gas temperature. Typical value = 1." },
3405 AttrDef { id: "GovGAST1.loadinc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Valve position change allowed at fast rate (Loadinc). Typical value = 0,05." },
3406 AttrDef { id: "GovGAST1.ltrate", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum long term fuel valve opening rate (Ltrate). Typical value = 0,02." },
3407 AttrDef { id: "GovGAST1.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
3408 AttrDef { id: "GovGAST1.pgv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 1, PU power (Pgv1). Typical value = 0." },
3409 AttrDef { id: "GovGAST1.pgv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 2, PU power (Pgv2). Typical value = 0." },
3410 AttrDef { id: "GovGAST1.pgv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 3, PU power (Pgv3). Typical value = 0." },
3411 AttrDef { id: "GovGAST1.pgv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 4, PU power (Pgv4). Typical value = 0." },
3412 AttrDef { id: "GovGAST1.pgv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 5, PU power (Pgv5). Typical value = 0." },
3413 AttrDef { id: "GovGAST1.pgv6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 6, PU power (Pgv6). Typical value = 0." },
3414 AttrDef { id: "GovGAST1.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Permanent droop (R) (>0). Typical value = 0,04." },
3415 AttrDef { id: "GovGAST1.rmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum fuel valve opening rate (Rmax). Unit = PU / s. Typical value = 1." },
3416 AttrDef { id: "GovGAST1.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor mechanism time constant (T1) (>= 0). T1 represents the natural valve positioning time constant of the governor for small disturbances, as seen when rate limiting is not in effect. Typical value = 0,5." },
3417 AttrDef { id: "GovGAST1.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine power time constant (T2) (>= 0). T2 represents delay due to internal energy storage of the gas turbine engine. T2 can be used to give a rough approximation to the delay associated with acceleration of the compressor spool of a multi-shaft engine, or with the compressibility of gas in the plenum of the free power turbine of an aero-derivative unit, for example. Typical value = 0,5." },
3418 AttrDef { id: "GovGAST1.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine exhaust temperature time constant (T3) (>= 0). T3 represents delay in the exhaust temperature and load limiting system. Typical value = 3." },
3419 AttrDef { id: "GovGAST1.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor lead time constant (T4) (>= 0). Typical value = 0." },
3420 AttrDef { id: "GovGAST1.t5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor lag time constant (T5) (>= 0). If = 0, entire gain and lead-lag block is bypassed. Typical value = 0." },
3421 AttrDef { id: "GovGAST1.tltr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Valve position averaging time constant (Tltr) (>= 0). Typical value = 10." },
3422 AttrDef { id: "GovGAST1.vmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum turbine power, PU of MWbase (Vmax) (> GovGAST1.vmin). Typical value = 1." },
3423 AttrDef { id: "GovGAST1.vmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum turbine power, PU of MWbase (Vmin) (< GovGAST1.vmax). Typical value = 0." },
3424 ],
3425 },
3426 ClassDef {
3427 ns: "http://iec.ch/TC57/CIM100#",
3428 local: "GovGAST2",
3429 qualified: "GovGAST2",
3430 super_class: Some(375),
3431 concrete: true,
3432 origins: &["DY"],
3433 comment: "Gas turbine.",
3434 attrs: &[
3435 AttrDef { id: "GovGAST2.a", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Valve positioner (A)." },
3436 AttrDef { id: "GovGAST2.af1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exhaust temperature parameter (Af1). Unit = PU temperature. Based on temperature in degrees C." },
3437 AttrDef { id: "GovGAST2.af2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient equal to 0,5(1-speed) (Af2)." },
3438 AttrDef { id: "GovGAST2.b", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Valve positioner (B)." },
3439 AttrDef { id: "GovGAST2.bf1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "(Bf1). Bf1 = E(1 - W) where E (speed sensitivity coefficient) is 0,55 to 0,65 x Tr. Unit = PU temperature. Based on temperature in degrees C." },
3440 AttrDef { id: "GovGAST2.bf2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine torque coefficient Khhv (depends on heating value of fuel stream in combustion chamber) (Bf2)." },
3441 AttrDef { id: "GovGAST2.c", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Valve positioner (C)." },
3442 AttrDef { id: "GovGAST2.cf2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient defining fuel flow where power output is 0% (Cf2). Synchronous but no output. Typically 0,23 x Khhv (23% fuel flow)." },
3443 AttrDef { id: "GovGAST2.ecr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Combustion reaction time delay (Ecr) (>= 0)." },
3444 AttrDef { id: "GovGAST2.etd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine and exhaust delay (Etd) (>= 0)." },
3445 AttrDef { id: "GovGAST2.k3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Ratio of fuel adjustment (K3)." },
3446 AttrDef { id: "GovGAST2.k4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain of radiation shield (K4)." },
3447 AttrDef { id: "GovGAST2.k5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain of radiation shield (K5)." },
3448 AttrDef { id: "GovGAST2.k6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum fuel flow (K6)." },
3449 AttrDef { id: "GovGAST2.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fuel system feedback (Kf)." },
3450 AttrDef { id: "GovGAST2.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
3451 AttrDef { id: "GovGAST2.t", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fuel control time constant (T) (>= 0)." },
3452 AttrDef { id: "GovGAST2.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Radiation shield time constant (T3) (>= 0)." },
3453 AttrDef { id: "GovGAST2.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Thermocouple time constant (T4) (>= 0)." },
3454 AttrDef { id: "GovGAST2.t5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Temperature control time constant (T5) (>= 0)." },
3455 AttrDef { id: "GovGAST2.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Temperature", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Temperature control (Tc). Unit = °F or °C depending on parameters Af1 and Bf1." },
3456 AttrDef { id: "GovGAST2.tcd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Compressor discharge time constant (Tcd) (>= 0)." },
3457 AttrDef { id: "GovGAST2.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fuel system time constant (Tf) (>= 0)." },
3458 AttrDef { id: "GovGAST2.tmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum turbine limit (Tmax) (> GovGAST2.tmin)." },
3459 AttrDef { id: "GovGAST2.tmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum turbine limit (Tmin) (< GovGAST2.tmax)." },
3460 AttrDef { id: "GovGAST2.tr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Temperature", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rated temperature (Tr). Unit = °C depending on parameters Af1 and Bf1." },
3461 AttrDef { id: "GovGAST2.trate", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine rating (Trate). Unit = MW." },
3462 AttrDef { id: "GovGAST2.tt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Temperature controller integration rate (Tt) (>= 0)." },
3463 AttrDef { id: "GovGAST2.w", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor gain (1/droop) on turbine rating (W)." },
3464 AttrDef { id: "GovGAST2.x", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor lead time constant (X) (>= 0)." },
3465 AttrDef { id: "GovGAST2.y", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor lag time constant (Y) (> 0)." },
3466 AttrDef { id: "GovGAST2.z", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["DY"], comment: "Governor mode (Z). 1 = droop 0 = isochronous." },
3467 ],
3468 },
3469 ClassDef {
3470 ns: "http://iec.ch/TC57/CIM100#",
3471 local: "GovGAST3",
3472 qualified: "GovGAST3",
3473 super_class: Some(375),
3474 concrete: true,
3475 origins: &["DY"],
3476 comment: "Generic turbogas with acceleration and temperature controller.",
3477 attrs: &[
3478 AttrDef { id: "GovGAST3.bca", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Acceleration limit set-point (Bca). Unit = 1/s. Typical value = 0,01." },
3479 AttrDef { id: "GovGAST3.bp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Droop (bp). Typical value = 0,05." },
3480 AttrDef { id: "GovGAST3.dtc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Temperature", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exhaust temperature variation due to fuel flow increasing from 0 to 1 PU (deltaTc). Typical value = 390." },
3481 AttrDef { id: "GovGAST3.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum fuel flow (Ka). Typical value = 0,23." },
3482 AttrDef { id: "GovGAST3.kac", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fuel system feedback (KAC). Typical value = 0." },
3483 AttrDef { id: "GovGAST3.kca", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Acceleration control integral gain (Kca). Unit = 1/s. Typical value = 100." },
3484 AttrDef { id: "GovGAST3.ksi", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain of radiation shield (Ksi). Typical value = 0,8." },
3485 AttrDef { id: "GovGAST3.ky", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient of transfer function of fuel valve positioner (Ky). Typical value = 1." },
3486 AttrDef { id: "GovGAST3.mnef", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fuel flow maximum negative error value (MNef). Typical value = -0,05." },
3487 AttrDef { id: "GovGAST3.mxef", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fuel flow maximum positive error value (MXef). Typical value = 0,05." },
3488 AttrDef { id: "GovGAST3.rcmn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum fuel flow (RCMN). Typical value = -0,1." },
3489 AttrDef { id: "GovGAST3.rcmx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum fuel flow (RCMX). Typical value = 1." },
3490 AttrDef { id: "GovGAST3.tac", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fuel control time constant (Tac) (>= 0). Typical value = 0,1." },
3491 AttrDef { id: "GovGAST3.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Compressor discharge volume time constant (Tc) (>= 0). Typical value = 0,2." },
3492 AttrDef { id: "GovGAST3.td", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Temperature controller derivative gain (Td) (>= 0). Typical value = 3,3." },
3493 AttrDef { id: "GovGAST3.tfen", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Temperature", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine rated exhaust temperature correspondent to Pm=1 PU (Tfen). Typical value = 540." },
3494 AttrDef { id: "GovGAST3.tg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of speed governor (Tg) (>= 0). Typical value = 0,05." },
3495 AttrDef { id: "GovGAST3.tsi", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of radiation shield (Tsi) (>= 0). Typical value = 15." },
3496 AttrDef { id: "GovGAST3.tt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Temperature", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Temperature controller integration rate (Tt). Typical value = 250." },
3497 AttrDef { id: "GovGAST3.ttc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of thermocouple (Ttc) (>= 0). Typical value = 2,5." },
3498 AttrDef { id: "GovGAST3.ty", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of fuel valve positioner (Ty) (>= 0). Typical value = 0,2." },
3499 ],
3500 },
3501 ClassDef {
3502 ns: "http://iec.ch/TC57/CIM100#",
3503 local: "GovGAST4",
3504 qualified: "GovGAST4",
3505 super_class: Some(375),
3506 concrete: true,
3507 origins: &["DY"],
3508 comment: "Generic turbogas.",
3509 attrs: &[
3510 AttrDef { id: "GovGAST4.bp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Droop (bp). Typical value = 0,05." },
3511 AttrDef { id: "GovGAST4.ktm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Compressor gain (Ktm). Typical value = 0." },
3512 AttrDef { id: "GovGAST4.mnef", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fuel flow maximum negative error value (MNef). Typical value = -0,05." },
3513 AttrDef { id: "GovGAST4.mxef", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fuel flow maximum positive error value (MXef). Typical value = 0,05." },
3514 AttrDef { id: "GovGAST4.rymn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum valve opening (RYMN). Typical value = 0." },
3515 AttrDef { id: "GovGAST4.rymx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum valve opening (RYMX). Typical value = 1,1." },
3516 AttrDef { id: "GovGAST4.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening velocity (TA) (>= 0). Typical value = 3." },
3517 AttrDef { id: "GovGAST4.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate closing velocity (TC) (>= 0). Typical value = 0,5." },
3518 AttrDef { id: "GovGAST4.tcm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fuel control time constant (Tcm) (>= 0). Typical value = 0,1." },
3519 AttrDef { id: "GovGAST4.tm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Compressor discharge volume time constant (Tm) (>= 0). Typical value = 0,2." },
3520 AttrDef { id: "GovGAST4.ty", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of fuel valve positioner (Ty) (>= 0). Typical value = 0,1." },
3521 ],
3522 },
3523 ClassDef {
3524 ns: "http://iec.ch/TC57/CIM100#",
3525 local: "GovGASTWD",
3526 qualified: "GovGASTWD",
3527 super_class: Some(375),
3528 concrete: true,
3529 origins: &["DY"],
3530 comment: "Woodward™ gas turbine governor. [Footnote: Woodward gas turbines are an example of suitable products available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of these products.]",
3531 attrs: &[
3532 AttrDef { id: "GovGASTWD.a", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Valve positioner (A)." },
3533 AttrDef { id: "GovGASTWD.af1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exhaust temperature parameter (Af1)." },
3534 AttrDef { id: "GovGASTWD.af2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient equal to 0,5(1-speed) (Af2)." },
3535 AttrDef { id: "GovGASTWD.b", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Valve positioner (B)." },
3536 AttrDef { id: "GovGASTWD.bf1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "(Bf1). Bf1 = E(1-w) where E (speed sensitivity coefficient) is 0,55 to 0,65 x Tr." },
3537 AttrDef { id: "GovGASTWD.bf2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine torque coefficient Khhv (depends on heating value of fuel stream in combustion chamber) (Bf2)." },
3538 AttrDef { id: "GovGASTWD.c", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Valve positioner (C)." },
3539 AttrDef { id: "GovGASTWD.cf2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient defining fuel flow where power output is 0 % (Cf2). Synchronous but no output. Typically 0,23 x Khhv (23 % fuel flow)." },
3540 AttrDef { id: "GovGASTWD.ecr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Combustion reaction time delay (Ecr) (>= 0)." },
3541 AttrDef { id: "GovGASTWD.etd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine and exhaust delay (Etd) (>= 0)." },
3542 AttrDef { id: "GovGASTWD.k3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Ratio of fuel adjustment (K3)." },
3543 AttrDef { id: "GovGASTWD.k4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain of radiation shield (K4)." },
3544 AttrDef { id: "GovGASTWD.k5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain of radiation shield (K5)." },
3545 AttrDef { id: "GovGASTWD.k6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum fuel flow (K6)." },
3546 AttrDef { id: "GovGASTWD.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Drop governor gain (Kd)." },
3547 AttrDef { id: "GovGASTWD.kdroop", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "(Kdroop) (>= 0)." },
3548 AttrDef { id: "GovGASTWD.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fuel system feedback (Kf)." },
3549 AttrDef { id: "GovGASTWD.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Isochronous Governor Gain (Ki)." },
3550 AttrDef { id: "GovGASTWD.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PID proportional gain (Kp)." },
3551 AttrDef { id: "GovGASTWD.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
3552 AttrDef { id: "GovGASTWD.t", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fuel control time constant (T) (>= 0)." },
3553 AttrDef { id: "GovGASTWD.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Radiation shield time constant (T3) (>= 0)." },
3554 AttrDef { id: "GovGASTWD.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Thermocouple time constant (T4) (>= 0)." },
3555 AttrDef { id: "GovGASTWD.t5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Temperature control time constant (T5) (>= 0)." },
3556 AttrDef { id: "GovGASTWD.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Temperature", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Temperature control (Tc)." },
3557 AttrDef { id: "GovGASTWD.tcd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Compressor discharge time constant (Tcd) (>= 0)." },
3558 AttrDef { id: "GovGASTWD.td", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power transducer time constant (Td) (>= 0)." },
3559 AttrDef { id: "GovGASTWD.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fuel system time constant (Tf) (>= 0)." },
3560 AttrDef { id: "GovGASTWD.tmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum Turbine limit (Tmax) (> GovGASTWD.tmin)." },
3561 AttrDef { id: "GovGASTWD.tmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum turbine limit (Tmin) (< GovGASTWD.tmax)." },
3562 AttrDef { id: "GovGASTWD.tr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Temperature", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rated temperature (Tr)." },
3563 AttrDef { id: "GovGASTWD.trate", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine rating (Trate). Unit = MW." },
3564 AttrDef { id: "GovGASTWD.tt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Temperature controller integration rate (Tt) (>= 0)." },
3565 ],
3566 },
3567 ClassDef {
3568 ns: "http://iec.ch/TC57/CIM100#",
3569 local: "GovHydro1",
3570 qualified: "GovHydro1",
3571 super_class: Some(375),
3572 concrete: true,
3573 origins: &["DY"],
3574 comment: "Basic hydro turbine governor.",
3575 attrs: &[
3576 AttrDef { id: "GovHydro1.at", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine gain (At) (> 0). Typical value = 1,2." },
3577 AttrDef { id: "GovHydro1.dturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine damping factor (Dturb) (>= 0). Typical value = 0,5." },
3578 AttrDef { id: "GovHydro1.gmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening (Gmax) (> 0 and > GovHydro.gmin). Typical value = 1." },
3579 AttrDef { id: "GovHydro1.gmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum gate opening (Gmin) (>= 0 and < GovHydro1.gmax). Typical value = 0." },
3580 AttrDef { id: "GovHydro1.hdam", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine nominal head (hdam). Typical value = 1." },
3581 AttrDef { id: "GovHydro1.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
3582 AttrDef { id: "GovHydro1.qnl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "No-load flow at nominal head (qnl) (>= 0). Typical value = 0,08." },
3583 AttrDef { id: "GovHydro1.rperm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Permanent droop (R) (> 0). Typical value = 0,04." },
3584 AttrDef { id: "GovHydro1.rtemp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Temporary droop (r) (> GovHydro1.rperm). Typical value = 0,3." },
3585 AttrDef { id: "GovHydro1.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter time constant (Tf) (> 0). Typical value = 0,05." },
3586 AttrDef { id: "GovHydro1.tg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate servo time constant (Tg) (> 0). Typical value = 0,5." },
3587 AttrDef { id: "GovHydro1.tr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Washout time constant (Tr) (> 0). Typical value = 5." },
3588 AttrDef { id: "GovHydro1.tw", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Water inertia time constant (Tw) (> 0). Typical value = 1." },
3589 AttrDef { id: "GovHydro1.velm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate velocity (Vlem) (> 0). Typical value = 0,2." },
3590 ],
3591 },
3592 ClassDef {
3593 ns: "http://iec.ch/TC57/CIM100#",
3594 local: "GovHydro2",
3595 qualified: "GovHydro2",
3596 super_class: Some(375),
3597 concrete: true,
3598 origins: &["DY"],
3599 comment: "IEEE hydro turbine governor with straightforward penstock configuration and hydraulic-dashpot governor.",
3600 attrs: &[
3601 AttrDef { id: "GovHydro2.aturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine numerator multiplier (Aturb). Typical value = -1." },
3602 AttrDef { id: "GovHydro2.bturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine denominator multiplier (Bturb) (> 0). Typical value = 0,5." },
3603 AttrDef { id: "GovHydro2.db1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intentional deadband width (db1). Unit = Hz. Typical value = 0." },
3604 AttrDef { id: "GovHydro2.db2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Unintentional deadband (db2). Unit = MW. Typical value = 0." },
3605 AttrDef { id: "GovHydro2.eps", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intentional db hysteresis (eps). Unit = Hz. Typical value = 0." },
3606 AttrDef { id: "GovHydro2.gv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 1, PU gv (Gv1). Typical value = 0." },
3607 AttrDef { id: "GovHydro2.gv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 2, PU gv (Gv2). Typical value = 0." },
3608 AttrDef { id: "GovHydro2.gv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 3, PU gv (Gv3). Typical value = 0." },
3609 AttrDef { id: "GovHydro2.gv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 4, PU gv (Gv4). Typical value = 0." },
3610 AttrDef { id: "GovHydro2.gv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 5, PU gv (Gv5). Typical value = 0." },
3611 AttrDef { id: "GovHydro2.gv6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 6, PU gv (Gv6). Typical value = 0." },
3612 AttrDef { id: "GovHydro2.kturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine gain (Kturb). Typical value = 1." },
3613 AttrDef { id: "GovHydro2.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
3614 AttrDef { id: "GovHydro2.pgv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 1, PU power (Pgv1). Typical value = 0." },
3615 AttrDef { id: "GovHydro2.pgv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 2, PU power (Pgv2). Typical value = 0." },
3616 AttrDef { id: "GovHydro2.pgv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 3, PU power (Pgv3). Typical value = 0." },
3617 AttrDef { id: "GovHydro2.pgv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 4, PU power (Pgv4). Typical value = 0." },
3618 AttrDef { id: "GovHydro2.pgv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 5, PU power (Pgv5). Typical value = 0." },
3619 AttrDef { id: "GovHydro2.pgv6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 6, PU power (Pgv6). Typical value = 0." },
3620 AttrDef { id: "GovHydro2.pmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening (Pmax) (> GovHydro2.pmin). Typical value = 1." },
3621 AttrDef { id: "GovHydro2.pmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum gate opening (Pmin) (< GovHydro2.pmax). Typical value = 0." },
3622 AttrDef { id: "GovHydro2.rperm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Permanent droop (Rperm). Typical value = 0,05." },
3623 AttrDef { id: "GovHydro2.rtemp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Temporary droop (Rtemp). Typical value = 0,5." },
3624 AttrDef { id: "GovHydro2.tg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate servo time constant (Tg) (> 0). Typical value = 0,5." },
3625 AttrDef { id: "GovHydro2.tp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pilot servo valve time constant (Tp) (>= 0). Typical value = 0,03." },
3626 AttrDef { id: "GovHydro2.tr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Dashpot time constant (Tr) (>= 0). Typical value = 12." },
3627 AttrDef { id: "GovHydro2.tw", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Water inertia time constant (Tw) (>= 0). Typical value = 2." },
3628 AttrDef { id: "GovHydro2.uc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate closing velocity (Uc) (< 0). Unit = PU / s. Typical value = -0,1." },
3629 AttrDef { id: "GovHydro2.uo", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening velocity (Uo). Unit = PU / s. Typical value = 0,1." },
3630 ],
3631 },
3632 ClassDef {
3633 ns: "http://iec.ch/TC57/CIM100#",
3634 local: "GovHydro3",
3635 qualified: "GovHydro3",
3636 super_class: Some(375),
3637 concrete: true,
3638 origins: &["DY"],
3639 comment: "Modified IEEE hydro governor-turbine. This model differs from that defined in the IEEE modelling guideline paper in that the limits on gate position and velocity do not permit 'wind up' of the upstream signals.",
3640 attrs: &[
3641 AttrDef { id: "GovHydro3.at", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine gain (At) (>0). Typical value = 1,2." },
3642 AttrDef { id: "GovHydro3.db1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intentional dead-band width (db1). Unit = Hz. Typical value = 0." },
3643 AttrDef { id: "GovHydro3.db2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Unintentional dead-band (db2). Unit = MW. Typical value = 0." },
3644 AttrDef { id: "GovHydro3.dturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine damping factor (Dturb). Typical value = 0,2." },
3645 AttrDef { id: "GovHydro3.eps", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intentional db hysteresis (eps). Unit = Hz. Typical value = 0." },
3646 AttrDef { id: "GovHydro3.governorControl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Governor control flag (Cflag). true = PID control is active false = double derivative control is active. Typical value = true." },
3647 AttrDef { id: "GovHydro3.gv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 1, PU gv (Gv1). Typical value = 0." },
3648 AttrDef { id: "GovHydro3.gv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 2, PU gv (Gv2). Typical value = 0." },
3649 AttrDef { id: "GovHydro3.gv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 3, PU gv (Gv3). Typical value = 0." },
3650 AttrDef { id: "GovHydro3.gv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 4, PU gv (Gv4). Typical value = 0." },
3651 AttrDef { id: "GovHydro3.gv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 5, PU gv (Gv5). Typical value = 0." },
3652 AttrDef { id: "GovHydro3.gv6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 6, PU gv (Gv6). Typical value = 0." },
3653 AttrDef { id: "GovHydro3.h0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine nominal head (H0). Typical value = 1." },
3654 AttrDef { id: "GovHydro3.k1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Derivative gain (K1). Typical value = 0,01." },
3655 AttrDef { id: "GovHydro3.k2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Double derivative gain, if Cflag = -1 (K2). Typical value = 2,5." },
3656 AttrDef { id: "GovHydro3.kg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate servo gain (Kg). Typical value = 2." },
3657 AttrDef { id: "GovHydro3.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Integral gain (Ki). Typical value = 0,5." },
3658 AttrDef { id: "GovHydro3.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
3659 AttrDef { id: "GovHydro3.pgv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 1, PU power (Pgv1). Typical value = 0." },
3660 AttrDef { id: "GovHydro3.pgv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 2, PU power (Pgv2). Typical value = 0." },
3661 AttrDef { id: "GovHydro3.pgv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 3, PU power (Pgv3). Typical value = 0." },
3662 AttrDef { id: "GovHydro3.pgv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 4, PU power (Pgv4). Typical value = 0." },
3663 AttrDef { id: "GovHydro3.pgv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 5, PU power (Pgv5). Typical value = 0." },
3664 AttrDef { id: "GovHydro3.pgv6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 6, PU power (Pgv6). Typical value = 0." },
3665 AttrDef { id: "GovHydro3.pmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening, PU of MWbase (Pmax) (> GovHydro3.pmin). Typical value = 1." },
3666 AttrDef { id: "GovHydro3.pmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum gate opening, PU of MWbase (Pmin) (< GovHydro3.pmax). Typical value = 0." },
3667 AttrDef { id: "GovHydro3.qnl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "No-load turbine flow at nominal head (Qnl). Typical value = 0,08." },
3668 AttrDef { id: "GovHydro3.relec", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Steady-state droop, PU, for electrical power feedback (Relec). Typical value = 0,05." },
3669 AttrDef { id: "GovHydro3.rgate", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Steady-state droop, PU, for governor output feedback (Rgate). Typical value = 0." },
3670 AttrDef { id: "GovHydro3.td", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input filter time constant (Td) (>= 0). Typical value = 0,05." },
3671 AttrDef { id: "GovHydro3.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Washout time constant (Tf) (>= 0). Typical value = 0,1." },
3672 AttrDef { id: "GovHydro3.tp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate servo time constant (Tp) (>= 0). Typical value = 0,05." },
3673 AttrDef { id: "GovHydro3.tt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power feedback time constant (Tt) (>= 0). Typical value = 0,2." },
3674 AttrDef { id: "GovHydro3.tw", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Water inertia time constant (Tw) (>= 0). If = 0, block is bypassed. Typical value = 1." },
3675 AttrDef { id: "GovHydro3.velcl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate closing velocity (Velcl). Unit = PU / s. Typical value = -0,2." },
3676 AttrDef { id: "GovHydro3.velop", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening velocity (Velop). Unit = PU / s. Typical value = 0,2." },
3677 ],
3678 },
3679 ClassDef {
3680 ns: "http://iec.ch/TC57/CIM100#",
3681 local: "GovHydro4",
3682 qualified: "GovHydro4",
3683 super_class: Some(375),
3684 concrete: true,
3685 origins: &["DY"],
3686 comment: "Hydro turbine and governor. Represents plants with straight-forward penstock configurations and hydraulic governors of the traditional 'dashpot' type. This model can be used to represent simple, Francis/Pelton or Kaplan turbines.",
3687 attrs: &[
3688 AttrDef { id: "GovHydro4.at", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine gain (At). Typical value = 1,2." },
3689 AttrDef { id: "GovHydro4.bgv0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Kaplan blade servo point 0 (Bgv0) (= 0 for simple, = 0 for Francis/Pelton). Typical value for Kaplan = 0." },
3690 AttrDef { id: "GovHydro4.bgv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Kaplan blade servo point 1 (Bgv1) (= 0 for simple, = 0 for Francis/Pelton). Typical value for Kaplan = 0." },
3691 AttrDef { id: "GovHydro4.bgv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Kaplan blade servo point 2 (Bgv2) (= 0 for simple, = 0 for Francis/Pelton). Typical value for Kaplan = 0,1." },
3692 AttrDef { id: "GovHydro4.bgv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Kaplan blade servo point 3 (Bgv3) (= 0 for simple, = 0 for Francis/Pelton). Typical value for Kaplan = 0,667." },
3693 AttrDef { id: "GovHydro4.bgv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Kaplan blade servo point 4 (Bgv4) (= 0 for simple, = 0 for Francis/Pelton). Typical value for Kaplan = 0,9." },
3694 AttrDef { id: "GovHydro4.bgv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Kaplan blade servo point 5 (Bgv5) (= 0 for simple, = 0 for Francis/Pelton). Typical value for Kaplan = 1." },
3695 AttrDef { id: "GovHydro4.bmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum blade adjustment factor (Bmax) (= 0 for simple, = 0 for Francis/Pelton). Typical value for Kaplan = 1,1276." },
3696 AttrDef { id: "GovHydro4.db1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intentional deadband width (db1). Unit = Hz. Typical value = 0." },
3697 AttrDef { id: "GovHydro4.db2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Unintentional dead-band (db2). Unit = MW. Typical value = 0." },
3698 AttrDef { id: "GovHydro4.dturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine damping factor (Dturb). Unit = delta P (PU of MWbase) / delta speed (PU). Typical value for simple = 0,5, Francis/Pelton = 1,1, Kaplan = 1,1." },
3699 AttrDef { id: "GovHydro4.eps", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intentional db hysteresis (eps). Unit = Hz. Typical value = 0." },
3700 AttrDef { id: "GovHydro4.gmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening, PU of MWbase (Gmax) (> GovHydro4.gmin). Typical value = 1." },
3701 AttrDef { id: "GovHydro4.gmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum gate opening, PU of MWbase (Gmin) (< GovHydro4.gmax). Typical value = 0." },
3702 AttrDef { id: "GovHydro4.gv0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 0, PU gv (Gv0) (= 0 for simple). Typical for Francis/Pelton = 0,1, Kaplan = 0,1." },
3703 AttrDef { id: "GovHydro4.gv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 1, PU gv (Gv1) (= 0 for simple, > GovHydro4.gv0 for Francis/Pelton and Kaplan). Typical value for Francis/Pelton = 0,4, Kaplan = 0,4." },
3704 AttrDef { id: "GovHydro4.gv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 2, PU gv (Gv2) (= 0 for simple, > GovHydro4.gv1 for Francis/Pelton and Kaplan). Typical value for Francis/Pelton = 0,5, Kaplan = 0,5." },
3705 AttrDef { id: "GovHydro4.gv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 3, PU gv (Gv3) (= 0 for simple, > GovHydro4.gv2 for Francis/Pelton and Kaplan). Typical value for Francis/Pelton = 0,7, Kaplan = 0,7." },
3706 AttrDef { id: "GovHydro4.gv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 4, PU gv (Gv4) (= 0 for simple, > GovHydro4.gv3 for Francis/Pelton and Kaplan). Typical value for Francis/Pelton = 0,8, Kaplan = 0,8." },
3707 AttrDef { id: "GovHydro4.gv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 5, PU gv (Gv5) (= 0 for simple, < 1 and > GovHydro4.gv4 for Francis/Pelton and Kaplan). Typical value for Francis/Pelton = 0,9, Kaplan = 0,9." },
3708 AttrDef { id: "GovHydro4.hdam", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Head available at dam (hdam). Typical value = 1." },
3709 AttrDef { id: "GovHydro4.model", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "GovHydro4ModelKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "The kind of model being represented (simple, Francis/Pelton or Kaplan)." },
3710 AttrDef { id: "GovHydro4.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
3711 AttrDef { id: "GovHydro4.pgv0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 0, PU power (Pgv0) (= 0 for simple). Typical value = 0." },
3712 AttrDef { id: "GovHydro4.pgv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 1, PU power (Pgv1) (= 0 for simple). Typical value for Francis/Pelton = 0,42, Kaplan = 0,35." },
3713 AttrDef { id: "GovHydro4.pgv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 2, PU power (Pgv2) (= 0 for simple). Typical value for Francis/Pelton = 0,56, Kaplan = 0,468." },
3714 AttrDef { id: "GovHydro4.pgv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 3, PU power (Pgv3) (= 0 for simple). Typical value for Francis/Pelton = 0,8, Kaplan = 0,796." },
3715 AttrDef { id: "GovHydro4.pgv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 4, PU power (Pgv4) (= 0 for simple). Typical value for Francis/Pelton = 0,9, Kaplan = 0,917." },
3716 AttrDef { id: "GovHydro4.pgv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 5, PU power (Pgv5) (= 0 for simple). Typical value for Francis/Pelton = 0,97, Kaplan = 0,99." },
3717 AttrDef { id: "GovHydro4.qnl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "No-load flow at nominal head (Qnl). Typical value for simple = 0,08, Francis/Pelton = 0, Kaplan = 0." },
3718 AttrDef { id: "GovHydro4.rperm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Permanent droop (Rperm) (>= 0). Typical value = 0,05." },
3719 AttrDef { id: "GovHydro4.rtemp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Temporary droop (Rtemp) (>= 0). Typical value = 0,3." },
3720 AttrDef { id: "GovHydro4.tblade", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Blade servo time constant (Tblade) (>= 0). Typical value = 100." },
3721 AttrDef { id: "GovHydro4.tg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate servo time constant (Tg) (> 0). Typical value = 0,5." },
3722 AttrDef { id: "GovHydro4.tp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pilot servo time constant (Tp) (>= 0). Typical value = 0,1." },
3723 AttrDef { id: "GovHydro4.tr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Dashpot time constant (Tr) (>= 0). Typical value = 5." },
3724 AttrDef { id: "GovHydro4.tw", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Water inertia time constant (Tw) (> 0). Typical value = 1." },
3725 AttrDef { id: "GovHydro4.uc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Max gate closing velocity (Uc). Typical value = 0,2." },
3726 AttrDef { id: "GovHydro4.uo", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Max gate opening velocity (Uo). Typical value = 0,2." },
3727 ],
3728 },
3729 ClassDef {
3730 ns: "http://iec.ch/TC57/CIM100#",
3731 local: "GovHydroDD",
3732 qualified: "GovHydroDD",
3733 super_class: Some(375),
3734 concrete: true,
3735 origins: &["DY"],
3736 comment: "Double derivative hydro governor and turbine.",
3737 attrs: &[
3738 AttrDef { id: "GovHydroDD.aturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine numerator multiplier (Aturb) (see parameter detail 3). Typical value = -1." },
3739 AttrDef { id: "GovHydroDD.bturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine denominator multiplier (Bturb) (see parameter detail 3). Typical value = 0,5." },
3740 AttrDef { id: "GovHydroDD.db1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intentional dead-band width (db1). Unit = Hz. Typical value = 0." },
3741 AttrDef { id: "GovHydroDD.db2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Unintentional dead-band (db2). Unit = MW. Typical value = 0." },
3742 AttrDef { id: "GovHydroDD.eps", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intentional db hysteresis (eps). Unit = Hz. Typical value = 0." },
3743 AttrDef { id: "GovHydroDD.gmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening (Gmax) (> GovHydroDD.gmin). Typical value = 0." },
3744 AttrDef { id: "GovHydroDD.gmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum gate opening (Gmin) (< GovHydroDD.gmax). Typical value = 0." },
3745 AttrDef { id: "GovHydroDD.gv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 1, PU gv (Gv1). Typical value = 0." },
3746 AttrDef { id: "GovHydroDD.gv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 2, PU gv (Gv2). Typical value = 0." },
3747 AttrDef { id: "GovHydroDD.gv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 3, PU gv (Gv3). Typical value = 0." },
3748 AttrDef { id: "GovHydroDD.gv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 4, PU gv (Gv4). Typical value = 0." },
3749 AttrDef { id: "GovHydroDD.gv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 5, PU gv (Gv5). Typical value = 0." },
3750 AttrDef { id: "GovHydroDD.gv6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 6, PU gv (Gv6). Typical value = 0." },
3751 AttrDef { id: "GovHydroDD.inputSignal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Input signal switch (Flag). true = Pe input is used false = feedback is received from CV. Flag is normally dependent on Tt. If Tt is zero, Flag is set to false. If Tt is not zero, Flag is set to true. Typical value = true." },
3752 AttrDef { id: "GovHydroDD.k1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Single derivative gain (K1). Typical value = 3,6." },
3753 AttrDef { id: "GovHydroDD.k2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Double derivative gain (K2). Typical value = 0,2." },
3754 AttrDef { id: "GovHydroDD.kg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate servo gain (Kg). Typical value = 3." },
3755 AttrDef { id: "GovHydroDD.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Integral gain (Ki). Typical value = 1." },
3756 AttrDef { id: "GovHydroDD.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (>0). Unit = MW." },
3757 AttrDef { id: "GovHydroDD.pgv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 1, PU power (Pgv1). Typical value = 0." },
3758 AttrDef { id: "GovHydroDD.pgv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 2, PU power (Pgv2). Typical value = 0." },
3759 AttrDef { id: "GovHydroDD.pgv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 3, PU power (Pgv3). Typical value = 0." },
3760 AttrDef { id: "GovHydroDD.pgv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 4, PU power (Pgv4). Typical value = 0." },
3761 AttrDef { id: "GovHydroDD.pgv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 5, PU power (Pgv5). Typical value = 0." },
3762 AttrDef { id: "GovHydroDD.pgv6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 6, PU power (Pgv6). Typical value = 0." },
3763 AttrDef { id: "GovHydroDD.pmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening, PU of MWbase (Pmax) (> GovHydroDD.pmin). Typical value = 1." },
3764 AttrDef { id: "GovHydroDD.pmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum gate opening, PU of MWbase (Pmin) (> GovHydroDD.pmax). Typical value = 0." },
3765 AttrDef { id: "GovHydroDD.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Steady state droop (R). Typical value = 0,05." },
3766 AttrDef { id: "GovHydroDD.td", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input filter time constant (Td) (>= 0). If = 0, block is bypassed. Typical value = 0." },
3767 AttrDef { id: "GovHydroDD.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Washout time constant (Tf) (>= 0). Typical value = 0,1." },
3768 AttrDef { id: "GovHydroDD.tp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate servo time constant (Tp) (>= 0). If = 0, block is bypassed. Typical value = 0,35." },
3769 AttrDef { id: "GovHydroDD.tt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power feedback time constant (Tt) (>= 0). If = 0, block is bypassed. Typical value = 0,02." },
3770 AttrDef { id: "GovHydroDD.tturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine time constant (Tturb) (>= 0). See parameter detail 3. Typical value = 0,8." },
3771 AttrDef { id: "GovHydroDD.velcl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate closing velocity (Velcl). Unit = PU / s. Typical value = -0,14." },
3772 AttrDef { id: "GovHydroDD.velop", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening velocity (Velop). Unit = PU / s. Typical value = 0,09." },
3773 ],
3774 },
3775 ClassDef {
3776 ns: "http://iec.ch/TC57/CIM100#",
3777 local: "GovHydroFrancis",
3778 qualified: "GovHydroFrancis",
3779 super_class: Some(375),
3780 concrete: true,
3781 origins: &["DY"],
3782 comment: "Detailed hydro unit - Francis model. This model can be used to represent three types of governors. A schematic of the hydraulic system of detailed hydro unit models, such as Francis and Pelton, is provided in the DetailedHydroModelHydraulicSystem diagram.",
3783 attrs: &[
3784 AttrDef { id: "GovHydroFrancis.am", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Opening section SEFF at the maximum efficiency (Am). Typical value = 0,7." },
3785 AttrDef { id: "GovHydroFrancis.av0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Area", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Area of the surge tank (AV0). Unit = m2. Typical value = 30." },
3786 AttrDef { id: "GovHydroFrancis.av1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Area", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Area of the compensation tank (AV1). Unit = m2. Typical value = 700." },
3787 AttrDef { id: "GovHydroFrancis.bp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Droop (Bp). Typical value = 0,05." },
3788 AttrDef { id: "GovHydroFrancis.db1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intentional dead-band width (DB1). Unit = Hz. Typical value = 0." },
3789 AttrDef { id: "GovHydroFrancis.etamax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum efficiency (EtaMax). Typical value = 1,05." },
3790 AttrDef { id: "GovHydroFrancis.governorControl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "FrancisGovernorControlKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Governor control flag (Cflag). Typical value = mechanicHydrolicTachoAccelerator." },
3791 AttrDef { id: "GovHydroFrancis.h1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Length", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Head of compensation chamber water level with respect to the level of penstock (H1). Unit = km. Typical value = 0,004." },
3792 AttrDef { id: "GovHydroFrancis.h2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Length", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Head of surge tank water level with respect to the level of penstock (H2). Unit = km. Typical value = 0,040." },
3793 AttrDef { id: "GovHydroFrancis.hn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Length", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rated hydraulic head (Hn). Unit = km. Typical value = 0,250." },
3794 AttrDef { id: "GovHydroFrancis.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Penstock loss coefficient (due to friction) (Kc). Typical value = 0,025." },
3795 AttrDef { id: "GovHydroFrancis.kg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Water tunnel and surge chamber loss coefficient (due to friction) (Kg). Typical value = 0,025." },
3796 AttrDef { id: "GovHydroFrancis.kt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Washout gain (Kt). Typical value = 0,25." },
3797 AttrDef { id: "GovHydroFrancis.qc0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "No-load turbine flow at nominal head (Qc0). Typical value = 0,1." },
3798 AttrDef { id: "GovHydroFrancis.qn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "VolumeFlowRate", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rated flow (Qn). Unit = m3/s. Typical value = 250." },
3799 AttrDef { id: "GovHydroFrancis.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Derivative gain (Ta) (>= 0). Typical value = 3." },
3800 AttrDef { id: "GovHydroFrancis.td", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Washout time constant (Td) (>= 0). Typical value = 6." },
3801 AttrDef { id: "GovHydroFrancis.ts", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate servo time constant (Ts) (>= 0). Typical value = 0,5." },
3802 AttrDef { id: "GovHydroFrancis.twnc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Water inertia time constant (Twnc) (>= 0). Typical value = 1." },
3803 AttrDef { id: "GovHydroFrancis.twng", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Water tunnel and surge chamber inertia time constant (Twng) (>= 0). Typical value = 3." },
3804 AttrDef { id: "GovHydroFrancis.tx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Derivative feedback gain (Tx) (>= 0). Typical value = 1." },
3805 AttrDef { id: "GovHydroFrancis.va", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening velocity (Va). Unit = PU / s. Typical value = 0,06." },
3806 AttrDef { id: "GovHydroFrancis.valvmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening (ValvMax) (> GovHydroFrancis.valvmin). Typical value = 1,1." },
3807 AttrDef { id: "GovHydroFrancis.valvmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum gate opening (ValvMin) (< GovHydroFrancis.valvmax). Typical value = 0." },
3808 AttrDef { id: "GovHydroFrancis.vc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate closing velocity (Vc). Unit = PU / s. Typical value = -0,06." },
3809 AttrDef { id: "GovHydroFrancis.waterTunnelSurgeChamberSimulation", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Water tunnel and surge chamber simulation (Tflag). true = enable of water tunnel and surge chamber simulation false = inhibit of water tunnel and surge chamber simulation. Typical value = false." },
3810 AttrDef { id: "GovHydroFrancis.zsfc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Length", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Head of upper water level with respect to the level of penstock (Zsfc). Unit = km. Typical value = 0,025." },
3811 ],
3812 },
3813 ClassDef {
3814 ns: "http://iec.ch/TC57/CIM100#",
3815 local: "GovHydroIEEE0",
3816 qualified: "GovHydroIEEE0",
3817 super_class: Some(375),
3818 concrete: true,
3819 origins: &["DY"],
3820 comment: "IEEE simplified hydro governor-turbine model. Used for mechanical-hydraulic and electro-hydraulic turbine governors, with or without steam feedback. Typical values given are for mechanical-hydraulic turbine-governor. Reference: IEEE Transactions on Power Apparatus and Systems, November/December 1973, Volume PAS-92, Number 6, Dynamic Models for Steam and Hydro Turbines in Power System Studies, page 1904.",
3821 attrs: &[
3822 AttrDef { id: "GovHydroIEEE0.k", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor gain (K)." },
3823 AttrDef { id: "GovHydroIEEE0.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
3824 AttrDef { id: "GovHydroIEEE0.pmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate maximum (Pmax) (> GovHydroIEEE0.pmin)." },
3825 AttrDef { id: "GovHydroIEEE0.pmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate minimum (Pmin) (< GovHydroIEEE.pmax)." },
3826 AttrDef { id: "GovHydroIEEE0.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor lag time constant (T1) (>= 0). Typical value = 0,25." },
3827 AttrDef { id: "GovHydroIEEE0.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor lead time constant (T2) (>= 0). Typical value = 0." },
3828 AttrDef { id: "GovHydroIEEE0.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate actuator time constant (T3) (>= 0). Typical value = 0,1." },
3829 AttrDef { id: "GovHydroIEEE0.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Water starting time (T4) (>= 0)." },
3830 ],
3831 },
3832 ClassDef {
3833 ns: "http://iec.ch/TC57/CIM100#",
3834 local: "GovHydroIEEE2",
3835 qualified: "GovHydroIEEE2",
3836 super_class: Some(375),
3837 concrete: true,
3838 origins: &["DY"],
3839 comment: "IEEE hydro turbine governor model represents plants with straightforward penstock configurations and hydraulic-dashpot governors. Reference: IEEE Transactions on Power Apparatus and Systems, November/December 1973, Volume PAS-92, Number 6, Dynamic Models for Steam and Hydro Turbines in Power System Studies, page 1904.",
3840 attrs: &[
3841 AttrDef { id: "GovHydroIEEE2.aturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine numerator multiplier (Aturb). Typical value = -1." },
3842 AttrDef { id: "GovHydroIEEE2.bturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine denominator multiplier (Bturb) (> 0). Typical value = 0,5." },
3843 AttrDef { id: "GovHydroIEEE2.gv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 1, PU gv (Gv1). Typical value = 0." },
3844 AttrDef { id: "GovHydroIEEE2.gv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 2, PU gv (Gv2). Typical value = 0." },
3845 AttrDef { id: "GovHydroIEEE2.gv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 3, PU gv (Gv3). Typical value = 0." },
3846 AttrDef { id: "GovHydroIEEE2.gv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 4, PU gv (Gv4). Typical value = 0." },
3847 AttrDef { id: "GovHydroIEEE2.gv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 5, PU gv (Gv5). Typical value = 0." },
3848 AttrDef { id: "GovHydroIEEE2.gv6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 6, PU gv (Gv6). Typical value = 0." },
3849 AttrDef { id: "GovHydroIEEE2.kturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine gain (Kturb). Typical value = 1." },
3850 AttrDef { id: "GovHydroIEEE2.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
3851 AttrDef { id: "GovHydroIEEE2.pgv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 1, PU power (Pgv1). Typical value = 0." },
3852 AttrDef { id: "GovHydroIEEE2.pgv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 2, PU power (Pgv2). Typical value = 0." },
3853 AttrDef { id: "GovHydroIEEE2.pgv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 3, PU power (Pgv3). Typical value = 0." },
3854 AttrDef { id: "GovHydroIEEE2.pgv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 4, PU power (Pgv4). Typical value = 0." },
3855 AttrDef { id: "GovHydroIEEE2.pgv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 5, PU power (Pgv5). Typical value = 0." },
3856 AttrDef { id: "GovHydroIEEE2.pgv6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 6, PU power (Pgv6). Typical value = 0." },
3857 AttrDef { id: "GovHydroIEEE2.pmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening (Pmax) (> GovHydroIEEE2.pmin). Typical value = 1." },
3858 AttrDef { id: "GovHydroIEEE2.pmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum gate opening (Pmin) (<GovHydroIEEE2.pmax). Typical value = 0." },
3859 AttrDef { id: "GovHydroIEEE2.rperm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Permanent droop (Rperm). Typical value = 0,05." },
3860 AttrDef { id: "GovHydroIEEE2.rtemp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Temporary droop (Rtemp). Typical value = 0,5." },
3861 AttrDef { id: "GovHydroIEEE2.tg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate servo time constant (Tg) (>= 0). Typical value = 0,5." },
3862 AttrDef { id: "GovHydroIEEE2.tp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pilot servo valve time constant (Tp) (>= 0). Typical value = 0,03." },
3863 AttrDef { id: "GovHydroIEEE2.tr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Dashpot time constant (Tr) (>= 0). Typical value = 12." },
3864 AttrDef { id: "GovHydroIEEE2.tw", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Water inertia time constant (Tw) (>= 0). Typical value = 2." },
3865 AttrDef { id: "GovHydroIEEE2.uc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate closing velocity (Uc) (<0). Typical value = -0,1." },
3866 AttrDef { id: "GovHydroIEEE2.uo", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening velocity (Uo). Unit = PU / s. Typical value = 0,1." },
3867 ],
3868 },
3869 ClassDef {
3870 ns: "http://iec.ch/TC57/CIM100#",
3871 local: "GovHydroPID",
3872 qualified: "GovHydroPID",
3873 super_class: Some(375),
3874 concrete: true,
3875 origins: &["DY"],
3876 comment: "PID governor and turbine.",
3877 attrs: &[
3878 AttrDef { id: "GovHydroPID.aturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine numerator multiplier (Aturb) (see parameter detail 3). Typical value -1." },
3879 AttrDef { id: "GovHydroPID.bturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine denominator multiplier (Bturb) (see parameter detail 3). Typical value = 0,5." },
3880 AttrDef { id: "GovHydroPID.db1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intentional dead-band width (db1). Unit = Hz. Typical value = 0." },
3881 AttrDef { id: "GovHydroPID.db2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Unintentional dead-band (db2). Unit = MW. Typical value = 0." },
3882 AttrDef { id: "GovHydroPID.eps", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intentional db hysteresis (eps). Unit = Hz. Typical value = 0." },
3883 AttrDef { id: "GovHydroPID.gv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 1, PU gv (Gv1). Typical value = 0." },
3884 AttrDef { id: "GovHydroPID.gv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 2, PU gv (Gv2). Typical value = 0." },
3885 AttrDef { id: "GovHydroPID.gv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 3, PU gv (Gv3). Typical value = 0." },
3886 AttrDef { id: "GovHydroPID.gv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 4, PU gv (Gv4). Typical value = 0." },
3887 AttrDef { id: "GovHydroPID.gv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 5, PU gv (Gv5). Typical value = 0." },
3888 AttrDef { id: "GovHydroPID.gv6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 6, PU gv (Gv6). Typical value = 0." },
3889 AttrDef { id: "GovHydroPID.inputSignal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Input signal switch (Flag). true = Pe input is used false = feedback is received from CV. Flag is normally dependent on Tt. If Tt is zero, Flag is set to false. If Tt is not zero, Flag is set to true. Typical value = true." },
3890 AttrDef { id: "GovHydroPID.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Derivative gain (Kd). Typical value = 1,11." },
3891 AttrDef { id: "GovHydroPID.kg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate servo gain (Kg). Typical value = 2,5." },
3892 AttrDef { id: "GovHydroPID.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Integral gain (Ki). Typical value = 0,36." },
3893 AttrDef { id: "GovHydroPID.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Proportional gain (Kp). Typical value = 0,1." },
3894 AttrDef { id: "GovHydroPID.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
3895 AttrDef { id: "GovHydroPID.pgv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 1, PU power (Pgv1). Typical value = 0." },
3896 AttrDef { id: "GovHydroPID.pgv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 2, PU power (Pgv2). Typical value = 0." },
3897 AttrDef { id: "GovHydroPID.pgv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 3, PU power (Pgv3). Typical value = 0." },
3898 AttrDef { id: "GovHydroPID.pgv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 4, PU power (Pgv4). Typical value = 0." },
3899 AttrDef { id: "GovHydroPID.pgv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 5, PU power (Pgv5). Typical value = 0." },
3900 AttrDef { id: "GovHydroPID.pgv6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 6, PU power (Pgv6). Typical value = 0." },
3901 AttrDef { id: "GovHydroPID.pmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening, PU of MWbase (Pmax) (> GovHydroPID.pmin). Typical value = 1." },
3902 AttrDef { id: "GovHydroPID.pmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum gate opening, PU of MWbase (Pmin) (< GovHydroPID.pmax). Typical value = 0." },
3903 AttrDef { id: "GovHydroPID.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Steady state droop (R). Typical value = 0,05." },
3904 AttrDef { id: "GovHydroPID.td", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input filter time constant (Td) (>= 0). If = 0, block is bypassed. Typical value = 0." },
3905 AttrDef { id: "GovHydroPID.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Washout time constant (Tf) (>= 0). Typical value = 0,1." },
3906 AttrDef { id: "GovHydroPID.tp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate servo time constant (Tp) (>= 0). If = 0, block is bypassed. Typical value = 0,35." },
3907 AttrDef { id: "GovHydroPID.tt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power feedback time constant (Tt) (>= 0). If = 0, block is bypassed. Typical value = 0,02." },
3908 AttrDef { id: "GovHydroPID.tturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine time constant (Tturb) (>= 0). See Parameter detail 3. Typical value = 0,8." },
3909 AttrDef { id: "GovHydroPID.velcl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate closing velocity (Velcl). Unit = PU / s. Typical value = -0,14." },
3910 AttrDef { id: "GovHydroPID.velop", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening velocity (Velop). Unit = PU / s. Typical value = 0,09." },
3911 ],
3912 },
3913 ClassDef {
3914 ns: "http://iec.ch/TC57/CIM100#",
3915 local: "GovHydroPID2",
3916 qualified: "GovHydroPID2",
3917 super_class: Some(375),
3918 concrete: true,
3919 origins: &["DY"],
3920 comment: "Hydro turbine and governor. Represents plants with straightforward penstock configurations and 'three term' electro-hydraulic governors (i.e. WoodwardTM electronic). [Footnote: Woodward electronic governors are an example of suitable products available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of these products.]",
3921 attrs: &[
3922 AttrDef { id: "GovHydroPID2.atw", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Factor multiplying Tw (Atw). Typical value = 0." },
3923 AttrDef { id: "GovHydroPID2.d", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine damping factor (D). Unit = delta P / delta speed. Typical value = 0." },
3924 AttrDef { id: "GovHydroPID2.feedbackSignal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Feedback signal type flag (Flag). true = use gate position feedback signal false = use Pe." },
3925 AttrDef { id: "GovHydroPID2.g0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate opening at speed no load (G0). Typical value = 0." },
3926 AttrDef { id: "GovHydroPID2.g1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate gate opening (G1). Typical value = 0." },
3927 AttrDef { id: "GovHydroPID2.g2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate gate opening (G2). Typical value = 0." },
3928 AttrDef { id: "GovHydroPID2.gmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening (Gmax) (> GovHydroPID2.gmin). Typical value = 0." },
3929 AttrDef { id: "GovHydroPID2.gmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum gate opening (Gmin) (> GovHydroPID2.gmax). Typical value = 0." },
3930 AttrDef { id: "GovHydroPID2.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Derivative gain (Kd). Typical value = 0." },
3931 AttrDef { id: "GovHydroPID2.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reset gain (Ki). Unit = PU/s. Typical value = 0." },
3932 AttrDef { id: "GovHydroPID2.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Proportional gain (Kp). Typical value = 0." },
3933 AttrDef { id: "GovHydroPID2.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (>0). Unit = MW." },
3934 AttrDef { id: "GovHydroPID2.p1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power at gate opening G1 (P1). Typical value = 0." },
3935 AttrDef { id: "GovHydroPID2.p2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power at gate opening G2 (P2). Typical value = 0." },
3936 AttrDef { id: "GovHydroPID2.p3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power at full opened gate (P3). Typical value = 0." },
3937 AttrDef { id: "GovHydroPID2.rperm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Permanent drop (Rperm). Typical value = 0." },
3938 AttrDef { id: "GovHydroPID2.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Controller time constant (Ta) (>= 0). Typical value = 0." },
3939 AttrDef { id: "GovHydroPID2.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate servo time constant (Tb) (> 0)." },
3940 AttrDef { id: "GovHydroPID2.treg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Speed detector time constant (Treg) (>= 0). Typical value = 0." },
3941 AttrDef { id: "GovHydroPID2.tw", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Water inertia time constant (Tw) (>= 0). Typical value = 0." },
3942 AttrDef { id: "GovHydroPID2.velmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening velocity (Velmax) (< GovHydroPID2.velmin). Unit = PU / s. Typical value = 0." },
3943 AttrDef { id: "GovHydroPID2.velmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate closing velocity (Velmin) (> GovHydroPID2.velmax). Unit = PU / s. Typical value = 0." },
3944 ],
3945 },
3946 ClassDef {
3947 ns: "http://iec.ch/TC57/CIM100#",
3948 local: "GovHydroPelton",
3949 qualified: "GovHydroPelton",
3950 super_class: Some(375),
3951 concrete: true,
3952 origins: &["DY"],
3953 comment: "Detailed hydro unit - Pelton model. This model can be used to represent the dynamic related to water tunnel and surge chamber. The DetailedHydroModelHydraulicSystem diagram, located under the GovHydroFrancis class, provides a schematic of the hydraulic system of detailed hydro unit models, such as Francis and Pelton.",
3954 attrs: &[
3955 AttrDef { id: "GovHydroPelton.av0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Area", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Area of the surge tank (AV0). Unit = m2. Typical value = 30." },
3956 AttrDef { id: "GovHydroPelton.av1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Area", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Area of the compensation tank (AV1). Unit = m2. Typical value = 700." },
3957 AttrDef { id: "GovHydroPelton.bp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Droop (bp). Typical value = 0,05." },
3958 AttrDef { id: "GovHydroPelton.db1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intentional dead-band width (DB1). Unit = Hz. Typical value = 0." },
3959 AttrDef { id: "GovHydroPelton.db2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intentional dead-band width of valve opening error (DB2). Unit = Hz. Typical value = 0,01." },
3960 AttrDef { id: "GovHydroPelton.h1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Length", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Head of compensation chamber water level with respect to the level of penstock (H1). Unit = km. Typical value = 0,004." },
3961 AttrDef { id: "GovHydroPelton.h2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Length", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Head of surge tank water level with respect to the level of penstock (H2). Unit = km. Typical value = 0,040." },
3962 AttrDef { id: "GovHydroPelton.hn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Length", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rated hydraulic head (Hn). Unit = km. Typical value = 0,250." },
3963 AttrDef { id: "GovHydroPelton.kc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Penstock loss coefficient (due to friction) (Kc). Typical value = 0,025." },
3964 AttrDef { id: "GovHydroPelton.kg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Water tunnel and surge chamber loss coefficient (due to friction) (Kg). Typical value = 0,025." },
3965 AttrDef { id: "GovHydroPelton.qc0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "No-load turbine flow at nominal head (Qc0). Typical value = 0,05." },
3966 AttrDef { id: "GovHydroPelton.qn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "VolumeFlowRate", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rated flow (Qn). Unit = m3/s. Typical value = 250." },
3967 AttrDef { id: "GovHydroPelton.simplifiedPelton", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Simplified Pelton model simulation (Sflag). true = enable of simplified Pelton model simulation false = enable of complete Pelton model simulation (non-linear gain). Typical value = true." },
3968 AttrDef { id: "GovHydroPelton.staticCompensating", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Static compensating characteristic (Cflag). It should be true if simplifiedPelton = false. true = enable of static compensating characteristic false = inhibit of static compensating characteristic. Typical value = false." },
3969 AttrDef { id: "GovHydroPelton.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Derivative gain (accelerometer time constant) (Ta) (>= 0). Typical value = 3." },
3970 AttrDef { id: "GovHydroPelton.ts", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate servo time constant (Ts) (>= 0). Typical value = 0,15." },
3971 AttrDef { id: "GovHydroPelton.tv", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Servomotor integrator time constant (Tv) (>= 0). Typical value = 0,3." },
3972 AttrDef { id: "GovHydroPelton.twnc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Water inertia time constant (Twnc) (>= 0). Typical value = 1." },
3973 AttrDef { id: "GovHydroPelton.twng", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Water tunnel and surge chamber inertia time constant (Twng) (>= 0). Typical value = 3." },
3974 AttrDef { id: "GovHydroPelton.tx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Electronic integrator time constant (Tx) (>= 0). Typical value = 0,5." },
3975 AttrDef { id: "GovHydroPelton.va", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening velocity (Va). Unit = PU / s. Typical value = 0,06." },
3976 AttrDef { id: "GovHydroPelton.valvmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening (ValvMax) (> GovHydroPelton.valvmin). Typical value = 1,1." },
3977 AttrDef { id: "GovHydroPelton.valvmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum gate opening (ValvMin) (< GovHydroPelton.valvmax). Typical value = 0." },
3978 AttrDef { id: "GovHydroPelton.vav", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum servomotor valve opening velocity (Vav). Typical value = 0,1." },
3979 AttrDef { id: "GovHydroPelton.vc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate closing velocity (Vc). Unit = PU / s. Typical value = -0,06." },
3980 AttrDef { id: "GovHydroPelton.vcv", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum servomotor valve closing velocity (Vcv). Typical value = -0,1." },
3981 AttrDef { id: "GovHydroPelton.waterTunnelSurgeChamberSimulation", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Water tunnel and surge chamber simulation (Tflag). true = enable of water tunnel and surge chamber simulation false = inhibit of water tunnel and surge chamber simulation. Typical value = false." },
3982 AttrDef { id: "GovHydroPelton.zsfc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Length", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Head of upper water level with respect to the level of penstock (Zsfc). Unit = km. Typical value = 0,025." },
3983 ],
3984 },
3985 ClassDef {
3986 ns: "http://iec.ch/TC57/CIM100#",
3987 local: "GovHydroR",
3988 qualified: "GovHydroR",
3989 super_class: Some(375),
3990 concrete: true,
3991 origins: &["DY"],
3992 comment: "Fourth order lead-lag governor and hydro turbine.",
3993 attrs: &[
3994 AttrDef { id: "GovHydroR.at", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine gain (At). Typical value = 1,2." },
3995 AttrDef { id: "GovHydroR.db1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intentional dead-band width (db1). Unit = Hz. Typical value = 0." },
3996 AttrDef { id: "GovHydroR.db2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Unintentional dead-band (db2). Unit = MW. Typical value = 0." },
3997 AttrDef { id: "GovHydroR.dturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine damping factor (Dturb). Typical value = 0,2." },
3998 AttrDef { id: "GovHydroR.eps", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intentional db hysteresis (eps). Unit = Hz. Typical value = 0." },
3999 AttrDef { id: "GovHydroR.gmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum governor output (Gmax) (> GovHydroR.gmin). Typical value = 1,05." },
4000 AttrDef { id: "GovHydroR.gmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum governor output (Gmin) (< GovHydroR.gmax). Typical value = -0,05." },
4001 AttrDef { id: "GovHydroR.gv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 1, PU gv (Gv1). Typical value = 0." },
4002 AttrDef { id: "GovHydroR.gv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 2, PU gv (Gv2). Typical value = 0." },
4003 AttrDef { id: "GovHydroR.gv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 3, PU gv (Gv3). Typical value = 0." },
4004 AttrDef { id: "GovHydroR.gv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 4, PU gv (Gv4). Typical value = 0." },
4005 AttrDef { id: "GovHydroR.gv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 5, PU gv (Gv5). Typical value = 0." },
4006 AttrDef { id: "GovHydroR.gv6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 6, PU gv (Gv6). Typical value = 0." },
4007 AttrDef { id: "GovHydroR.h0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine nominal head (H0). Typical value = 1." },
4008 AttrDef { id: "GovHydroR.inputSignal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Input signal switch (Flag). true = Pe input is used false = feedback is received from CV. Flag is normally dependent on Tt. If Tt is zero, Flag is set to false. If Tt is not zero, Flag is set to true. Typical value = true." },
4009 AttrDef { id: "GovHydroR.kg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate servo gain (Kg). Typical value = 2." },
4010 AttrDef { id: "GovHydroR.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Integral gain (Ki). Typical value = 0,5." },
4011 AttrDef { id: "GovHydroR.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
4012 AttrDef { id: "GovHydroR.pgv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 1, PU power (Pgv1). Typical value = 0." },
4013 AttrDef { id: "GovHydroR.pgv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 2, PU power (Pgv2). Typical value = 0." },
4014 AttrDef { id: "GovHydroR.pgv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 3, PU power (Pgv3). Typical value = 0." },
4015 AttrDef { id: "GovHydroR.pgv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 4, PU power (Pgv4). Typical value = 0." },
4016 AttrDef { id: "GovHydroR.pgv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 5, PU power (Pgv5). Typical value = 0." },
4017 AttrDef { id: "GovHydroR.pgv6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain point 6, PU power (Pgv6). Typical value = 0." },
4018 AttrDef { id: "GovHydroR.pmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening, PU of MWbase (Pmax) (> GovHydroR.pmin). Typical value = 1." },
4019 AttrDef { id: "GovHydroR.pmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum gate opening, PU of MWbase (Pmin) (< GovHydroR.pmax). Typical value = 0." },
4020 AttrDef { id: "GovHydroR.qnl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "No-load turbine flow at nominal head (Qnl). Typical value = 0,08." },
4021 AttrDef { id: "GovHydroR.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Steady-state droop (R). Typical value = 0,05." },
4022 AttrDef { id: "GovHydroR.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead time constant 1 (T1) (>= 0). Typical value = 1,5." },
4023 AttrDef { id: "GovHydroR.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant 1 (T2) (>= 0). Typical value = 0,1." },
4024 AttrDef { id: "GovHydroR.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead time constant 2 (T3) (>= 0). Typical value = 1,5." },
4025 AttrDef { id: "GovHydroR.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant 2 (T4) (>= 0). Typical value = 0,1." },
4026 AttrDef { id: "GovHydroR.t5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead time constant 3 (T5) (>= 0). Typical value = 0." },
4027 AttrDef { id: "GovHydroR.t6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant 3 (T6) (>= 0). Typical value = 0,05." },
4028 AttrDef { id: "GovHydroR.t7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead time constant 4 (T7) (>= 0). Typical value = 0." },
4029 AttrDef { id: "GovHydroR.t8", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant 4 (T8) (>= 0). Typical value = 0,05." },
4030 AttrDef { id: "GovHydroR.td", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input filter time constant (Td) (>= 0). Typical value = 0,05." },
4031 AttrDef { id: "GovHydroR.tp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate servo time constant (Tp) (>= 0). Typical value = 0,05." },
4032 AttrDef { id: "GovHydroR.tt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power feedback time constant (Tt) (>= 0). Typical value = 0." },
4033 AttrDef { id: "GovHydroR.tw", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Water inertia time constant (Tw) (> 0). Typical value = 1." },
4034 AttrDef { id: "GovHydroR.velcl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate closing velocity (Velcl). Unit = PU / s. Typical value = -0,2." },
4035 AttrDef { id: "GovHydroR.velop", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening velocity (Velop). Unit = PU / s. Typical value = 0,2." },
4036 ],
4037 },
4038 ClassDef {
4039 ns: "http://iec.ch/TC57/CIM100#",
4040 local: "GovHydroWEH",
4041 qualified: "GovHydroWEH",
4042 super_class: Some(375),
4043 concrete: true,
4044 origins: &["DY"],
4045 comment: "WoodwardTM electric hydro governor. [Footnote: Woodward electric hydro governors are an example of suitable products available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of these products.]",
4046 attrs: &[
4047 AttrDef { id: "GovHydroWEH.db", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Speed deadband (db)." },
4048 AttrDef { id: "GovHydroWEH.dicn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Value to allow the integral controller to advance beyond the gate limits (Dicn)." },
4049 AttrDef { id: "GovHydroWEH.dpv", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Value to allow the pilot valve controller to advance beyond the gate limits (Dpv)." },
4050 AttrDef { id: "GovHydroWEH.dturb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine damping factor (Dturb). Unit = delta P (PU of MWbase) / delta speed (PU)." },
4051 AttrDef { id: "GovHydroWEH.feedbackSignal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Feedback signal selection (Sw). true = PID output (if R-Perm-Gate = droop and R-Perm-Pe = 0) false = electrical power (if R-Perm-Gate = 0 and R-Perm-Pe = droop) or false = gate position (if R-Perm-Gate = droop and R-Perm-Pe = 0). Typical value = false." },
4052 AttrDef { id: "GovHydroWEH.fl1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Flowgate 1 (Fl1). Flow value for gate position point 1 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow." },
4053 AttrDef { id: "GovHydroWEH.fl2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Flowgate 2 (Fl2). Flow value for gate position point 2 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow." },
4054 AttrDef { id: "GovHydroWEH.fl3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Flowgate 3 (Fl3). Flow value for gate position point 3 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow." },
4055 AttrDef { id: "GovHydroWEH.fl4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Flowgate 4 (Fl4). Flow value for gate position point 4 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow." },
4056 AttrDef { id: "GovHydroWEH.fl5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Flowgate 5 (Fl5). Flow value for gate position point 5 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow." },
4057 AttrDef { id: "GovHydroWEH.fp1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Flow P1 (Fp1). Turbine flow value for point 1 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4058 AttrDef { id: "GovHydroWEH.fp10", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Flow P10 (Fp10). Turbine flow value for point 10 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4059 AttrDef { id: "GovHydroWEH.fp2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Flow P2 (Fp2). Turbine flow value for point 2 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4060 AttrDef { id: "GovHydroWEH.fp3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Flow P3 (Fp3). Turbine flow value for point 3 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4061 AttrDef { id: "GovHydroWEH.fp4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Flow P4 (Fp4). Turbine flow value for point 4 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4062 AttrDef { id: "GovHydroWEH.fp5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Flow P5 (Fp5). Turbine flow value for point 5 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4063 AttrDef { id: "GovHydroWEH.fp6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Flow P6 (Fp6). Turbine flow value for point 6 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4064 AttrDef { id: "GovHydroWEH.fp7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Flow P7 (Fp7). Turbine flow value for point 7 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4065 AttrDef { id: "GovHydroWEH.fp8", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Flow P8 (Fp8). Turbine flow value for point 8 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4066 AttrDef { id: "GovHydroWEH.fp9", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Flow P9 (Fp9). Turbine flow value for point 9 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4067 AttrDef { id: "GovHydroWEH.gmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate position (Gmax) (> GovHydroWEH.gmin)." },
4068 AttrDef { id: "GovHydroWEH.gmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum gate position (Gmin) (< GovHydroWEH.gmax)." },
4069 AttrDef { id: "GovHydroWEH.gtmxcl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate closing rate (Gtmxcl)." },
4070 AttrDef { id: "GovHydroWEH.gtmxop", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening rate (Gtmxop)." },
4071 AttrDef { id: "GovHydroWEH.gv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate 1 (Gv1). Gate Position value for point 1 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow." },
4072 AttrDef { id: "GovHydroWEH.gv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate 2 (Gv2). Gate Position value for point 2 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow." },
4073 AttrDef { id: "GovHydroWEH.gv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate 3 (Gv3). Gate Position value for point 3 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow." },
4074 AttrDef { id: "GovHydroWEH.gv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate 4 (Gv4). Gate Position value for point 4 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow." },
4075 AttrDef { id: "GovHydroWEH.gv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate 5 (Gv5). Gate Position value for point 5 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow." },
4076 AttrDef { id: "GovHydroWEH.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Derivative controller derivative gain (Kd)." },
4077 AttrDef { id: "GovHydroWEH.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Derivative controller Integral gain (Ki)." },
4078 AttrDef { id: "GovHydroWEH.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Derivative control gain (Kp)." },
4079 AttrDef { id: "GovHydroWEH.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
4080 AttrDef { id: "GovHydroWEH.pmss1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pmss flow P1 (Pmss1). Mechanical power output for turbine flow point 1 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4081 AttrDef { id: "GovHydroWEH.pmss10", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pmss flow P10 (Pmss10). Mechanical power output for turbine flow point 10 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4082 AttrDef { id: "GovHydroWEH.pmss2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pmss flow P2 (Pmss2). Mechanical power output for turbine flow point 2 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4083 AttrDef { id: "GovHydroWEH.pmss3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pmss flow P3 (Pmss3). Mechanical power output for turbine flow point 3 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4084 AttrDef { id: "GovHydroWEH.pmss4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pmss flow P4 (Pmss4). Mechanical power output for turbine flow point 4 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4085 AttrDef { id: "GovHydroWEH.pmss5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pmss flow P5 (Pmss5). Mechanical power output for turbine flow point 5 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4086 AttrDef { id: "GovHydroWEH.pmss6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pmss flow P6 (Pmss6). Mechanical power output for turbine flow point 6 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4087 AttrDef { id: "GovHydroWEH.pmss7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pmss flow P7 (Pmss7). Mechanical power output for turbine flow point 7 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4088 AttrDef { id: "GovHydroWEH.pmss8", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pmss flow P8 (Pmss8). Mechanical power output for turbine flow point 8 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4089 AttrDef { id: "GovHydroWEH.pmss9", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pmss flow P9 (Pmss9). Mechanical power output for turbine flow point 9 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow." },
4090 AttrDef { id: "GovHydroWEH.rpg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Permanent droop for governor output feedback (R-Perm-Gate)." },
4091 AttrDef { id: "GovHydroWEH.rpp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Permanent droop for electrical power feedback (R-Perm-Pe)." },
4092 AttrDef { id: "GovHydroWEH.td", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Derivative controller time constant (Td) (>= 0). Limits the derivative characteristic beyond a breakdown frequency to avoid amplification of high-frequency noise." },
4093 AttrDef { id: "GovHydroWEH.tdv", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Distributive valve time lag time constant (Tdv) (>= 0)." },
4094 AttrDef { id: "GovHydroWEH.tg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Value to allow the distribution valve controller to advance beyond the gate movement rate limit (Tg) (>= 0)." },
4095 AttrDef { id: "GovHydroWEH.tp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pilot valve time lag time constant (Tp) (>= 0)." },
4096 AttrDef { id: "GovHydroWEH.tpe", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Electrical power droop time constant (Tpe) (>= 0)." },
4097 AttrDef { id: "GovHydroWEH.tw", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Water inertia time constant (Tw) (> 0)." },
4098 ],
4099 },
4100 ClassDef {
4101 ns: "http://iec.ch/TC57/CIM100#",
4102 local: "GovHydroWPID",
4103 qualified: "GovHydroWPID",
4104 super_class: Some(375),
4105 concrete: true,
4106 origins: &["DY"],
4107 comment: "WoodwardTM PID hydro governor. [Footnote: Woodward PID hydro governors are an example of suitable products available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of these products.]",
4108 attrs: &[
4109 AttrDef { id: "GovHydroWPID.d", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine damping factor (D). Unit = delta P / delta speed." },
4110 AttrDef { id: "GovHydroWPID.gatmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate opening limit maximum (Gatmax) (> GovHydroWPID.gatmin)." },
4111 AttrDef { id: "GovHydroWPID.gatmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate opening limit minimum (Gatmin) (< GovHydroWPID.gatmax)." },
4112 AttrDef { id: "GovHydroWPID.gv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate position 1 (Gv1)." },
4113 AttrDef { id: "GovHydroWPID.gv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate position 2 (Gv2)." },
4114 AttrDef { id: "GovHydroWPID.gv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate position 3 (Gv3) (= 1,0)." },
4115 AttrDef { id: "GovHydroWPID.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Derivative gain (Kd). Typical value = 1,11." },
4116 AttrDef { id: "GovHydroWPID.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reset gain (Ki). Typical value = 0,36." },
4117 AttrDef { id: "GovHydroWPID.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Proportional gain (Kp). Typical value = 0,1." },
4118 AttrDef { id: "GovHydroWPID.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
4119 AttrDef { id: "GovHydroWPID.pgv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Output at Gv1 PU of MWbase (Pgv1)." },
4120 AttrDef { id: "GovHydroWPID.pgv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Output at Gv2 PU of MWbase (Pgv2)." },
4121 AttrDef { id: "GovHydroWPID.pgv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Output at Gv3 PU of MWbase (Pgv3)." },
4122 AttrDef { id: "GovHydroWPID.pmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum power output (Pmax) (> GovHydroWPID.pmin)." },
4123 AttrDef { id: "GovHydroWPID.pmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum power output (Pmin) (< GovHydroWPID.pmax)." },
4124 AttrDef { id: "GovHydroWPID.reg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Permanent drop (Reg)." },
4125 AttrDef { id: "GovHydroWPID.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Controller time constant (Ta) (>= 0). Typical value = 0." },
4126 AttrDef { id: "GovHydroWPID.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gate servo time constant (Tb) (>= 0). Typical value = 0." },
4127 AttrDef { id: "GovHydroWPID.treg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Speed detector time constant (Treg) (>= 0)." },
4128 AttrDef { id: "GovHydroWPID.tw", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Water inertia time constant (Tw) (>= 0). Typical value = 0." },
4129 AttrDef { id: "GovHydroWPID.velmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate opening velocity (Velmax) (> GovHydroWPID.velmin). Unit = PU / s. Typical value = 0." },
4130 AttrDef { id: "GovHydroWPID.velmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum gate closing velocity (Velmin) (< GovHydroWPID.velmax). Unit = PU / s. Typical value = 0." },
4131 ],
4132 },
4133 ClassDef {
4134 ns: "http://iec.ch/TC57/CIM100#",
4135 local: "GovSteam0",
4136 qualified: "GovSteam0",
4137 super_class: Some(375),
4138 concrete: true,
4139 origins: &["DY"],
4140 comment: "A simplified steam turbine governor.",
4141 attrs: &[
4142 AttrDef { id: "GovSteam0.dt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Turbine damping coefficient (Dt). Unit = delta P / delta speed. Typical value = 0." },
4143 AttrDef { id: "GovSteam0.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
4144 AttrDef { id: "GovSteam0.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Permanent droop (R). Typical value = 0,05." },
4145 AttrDef { id: "GovSteam0.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Steam bowl time constant (T1) (> 0). Typical value = 0,5." },
4146 AttrDef { id: "GovSteam0.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Numerator time constant of T2/T3 block (T2) (>= 0). Typical value = 3." },
4147 AttrDef { id: "GovSteam0.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reheater time constant (T3) (> 0). Typical value = 10." },
4148 AttrDef { id: "GovSteam0.vmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum valve position, PU of mwcap (Vmax) (> GovSteam0.vmin). Typical value = 1." },
4149 AttrDef { id: "GovSteam0.vmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum valve position, PU of mwcap (Vmin) (< GovSteam0.vmax). Typical value = 0." },
4150 ],
4151 },
4152 ClassDef {
4153 ns: "http://iec.ch/TC57/CIM100#",
4154 local: "GovSteam1",
4155 qualified: "GovSteam1",
4156 super_class: Some(375),
4157 concrete: true,
4158 origins: &["DY"],
4159 comment: "Steam turbine governor, based on the GovSteamIEEE1 (with optional deadband and nonlinear valve gain added).",
4160 attrs: &[
4161 AttrDef { id: "GovSteam1.db1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intentional deadband width (db1). Unit = Hz. Typical value = 0." },
4162 AttrDef { id: "GovSteam1.db2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Unintentional deadband (db2). Unit = MW. Typical value = 0." },
4163 AttrDef { id: "GovSteam1.eps", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Frequency", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intentional db hysteresis (eps). Unit = Hz. Typical value = 0." },
4164 AttrDef { id: "GovSteam1.gv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain valve position point 1 (GV1). Typical value = 0." },
4165 AttrDef { id: "GovSteam1.gv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain valve position point 2 (GV2). Typical value = 0,4." },
4166 AttrDef { id: "GovSteam1.gv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain valve position point 3 (GV3). Typical value = 0,5." },
4167 AttrDef { id: "GovSteam1.gv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain valve position point 4 (GV4). Typical value = 0,6." },
4168 AttrDef { id: "GovSteam1.gv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain valve position point 5 (GV5). Typical value = 1." },
4169 AttrDef { id: "GovSteam1.gv6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain valve position point 6 (GV6). Typical value = 0." },
4170 AttrDef { id: "GovSteam1.k", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor gain (reciprocal of droop) (K) (> 0). Typical value = 25." },
4171 AttrDef { id: "GovSteam1.k1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of HP shaft power after first boiler pass (K1). Typical value = 0,2." },
4172 AttrDef { id: "GovSteam1.k2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of LP shaft power after first boiler pass (K2). Typical value = 0." },
4173 AttrDef { id: "GovSteam1.k3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of HP shaft power after second boiler pass (K3). Typical value = 0,3." },
4174 AttrDef { id: "GovSteam1.k4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of LP shaft power after second boiler pass (K4). Typical value = 0." },
4175 AttrDef { id: "GovSteam1.k5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of HP shaft power after third boiler pass (K5). Typical value = 0,5." },
4176 AttrDef { id: "GovSteam1.k6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of LP shaft power after third boiler pass (K6). Typical value = 0." },
4177 AttrDef { id: "GovSteam1.k7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of HP shaft power after fourth boiler pass (K7). Typical value = 0." },
4178 AttrDef { id: "GovSteam1.k8", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of LP shaft power after fourth boiler pass (K8). Typical value = 0." },
4179 AttrDef { id: "GovSteam1.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
4180 AttrDef { id: "GovSteam1.pgv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain power value point 1 (Pgv1). Typical value = 0." },
4181 AttrDef { id: "GovSteam1.pgv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain power value point 2 (Pgv2). Typical value = 0,75." },
4182 AttrDef { id: "GovSteam1.pgv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain power value point 3 (Pgv3). Typical value = 0,91." },
4183 AttrDef { id: "GovSteam1.pgv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain power value point 4 (Pgv4). Typical value = 0,98." },
4184 AttrDef { id: "GovSteam1.pgv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain power value point 5 (Pgv5). Typical value = 1." },
4185 AttrDef { id: "GovSteam1.pgv6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain power value point 6 (Pgv6). Typical value = 0." },
4186 AttrDef { id: "GovSteam1.pmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum valve opening (Pmax) (> GovSteam1.pmin). Typical value = 1." },
4187 AttrDef { id: "GovSteam1.pmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum valve opening (Pmin) (>= 0 and < GovSteam1.pmax). Typical value = 0." },
4188 AttrDef { id: "GovSteam1.sdb1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Intentional deadband indicator. true = intentional deadband is applied false = intentional deadband is not applied. Typical value = true." },
4189 AttrDef { id: "GovSteam1.sdb2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Unintentional deadband location. true = intentional deadband is applied before point 'A' false = intentional deadband is applied after point 'A'. Typical value = true." },
4190 AttrDef { id: "GovSteam1.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor lag time constant (T1) (>= 0). Typical value = 0." },
4191 AttrDef { id: "GovSteam1.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor lead time constant (T2) (>= 0). Typical value = 0." },
4192 AttrDef { id: "GovSteam1.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Valve positioner time constant (T3) (> 0). Typical value = 0,1." },
4193 AttrDef { id: "GovSteam1.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Inlet piping/steam bowl time constant (T4) (>= 0). Typical value = 0,3." },
4194 AttrDef { id: "GovSteam1.t5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of second boiler pass (T5) (>= 0). Typical value = 5." },
4195 AttrDef { id: "GovSteam1.t6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of third boiler pass (T6) (>= 0). Typical value = 0,5." },
4196 AttrDef { id: "GovSteam1.t7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of fourth boiler pass (T7) (>= 0). Typical value = 0." },
4197 AttrDef { id: "GovSteam1.uc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum valve closing velocity (Uc) (< 0). Unit = PU / s. Typical value = -10." },
4198 AttrDef { id: "GovSteam1.uo", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum valve opening velocity (Uo) (> 0). Unit = PU / s. Typical value = 1." },
4199 AttrDef { id: "GovSteam1.valve", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Nonlinear valve characteristic. true = nonlinear valve characteristic is used false = nonlinear valve characteristic is not used. Typical value = true." },
4200 ],
4201 },
4202 ClassDef {
4203 ns: "http://iec.ch/TC57/CIM100#",
4204 local: "GovSteam2",
4205 qualified: "GovSteam2",
4206 super_class: Some(375),
4207 concrete: true,
4208 origins: &["DY"],
4209 comment: "Simplified governor.",
4210 attrs: &[
4211 AttrDef { id: "GovSteam2.dbf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency deadband (DBF). Typical value = 0." },
4212 AttrDef { id: "GovSteam2.k", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor gain (reciprocal of droop) (K). Typical value = 20." },
4213 AttrDef { id: "GovSteam2.mnef", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fuel flow maximum negative error value (MNEF). Typical value = -1." },
4214 AttrDef { id: "GovSteam2.mxef", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fuel flow maximum positive error value (MXEF). Typical value = 1." },
4215 AttrDef { id: "GovSteam2.pmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum fuel flow (PMAX) (> GovSteam2.pmin). Typical value = 1." },
4216 AttrDef { id: "GovSteam2.pmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum fuel flow (PMIN) (< GovSteam2.pmax). Typical value = 0." },
4217 AttrDef { id: "GovSteam2.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor lag time constant (T1) (> 0). Typical value = 0,45." },
4218 AttrDef { id: "GovSteam2.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor lead time constant (T2) (>= 0). Typical value = 0." },
4219 ],
4220 },
4221 ClassDef {
4222 ns: "http://iec.ch/TC57/CIM100#",
4223 local: "GovSteamBB",
4224 qualified: "GovSteamBB",
4225 super_class: Some(375),
4226 concrete: true,
4227 origins: &["DY"],
4228 comment: "European governor model.",
4229 attrs: &[
4230 AttrDef { id: "GovSteamBB.fcut", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency deadband (fcut) (>= 0). Typical value = 0,002." },
4231 AttrDef { id: "GovSteamBB.k2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (K2). Typical value = 0,75." },
4232 AttrDef { id: "GovSteamBB.k3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (K3). Typical value = 0,5." },
4233 AttrDef { id: "GovSteamBB.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (Kd). Typical value = 1,0." },
4234 AttrDef { id: "GovSteamBB.kg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (Kg). Typical value = 1,0." },
4235 AttrDef { id: "GovSteamBB.kls", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (Kls) (> 0). Typical value = 0,1." },
4236 AttrDef { id: "GovSteamBB.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (Kp). Typical value = 1,0." },
4237 AttrDef { id: "GovSteamBB.ks", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (Ks). Typical value = 21,0." },
4238 AttrDef { id: "GovSteamBB.peflag", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Electric power input selection (Peflag). true = electric power input false = feedback signal. Typical value = false." },
4239 AttrDef { id: "GovSteamBB.pmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High power limit (Pmax) (> GovSteamBB.pmin). Typical value = 1,0." },
4240 AttrDef { id: "GovSteamBB.pmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low power limit (Pmin) (< GovSteamBB.pmax). Typical value = 0." },
4241 AttrDef { id: "GovSteamBB.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T1). Typical value = 0,05." },
4242 AttrDef { id: "GovSteamBB.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T4). Typical value = 0,15." },
4243 AttrDef { id: "GovSteamBB.t5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T5). Typical value = 12,0." },
4244 AttrDef { id: "GovSteamBB.t6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T6). Typical value = 0,75." },
4245 AttrDef { id: "GovSteamBB.td", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Td) (> 0). Typical value = 1,0." },
4246 AttrDef { id: "GovSteamBB.tn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Tn) (> 0). Typical value = 1,0." },
4247 ],
4248 },
4249 ClassDef {
4250 ns: "http://iec.ch/TC57/CIM100#",
4251 local: "GovSteamCC",
4252 qualified: "GovSteamCC",
4253 super_class: Some(49),
4254 concrete: true,
4255 origins: &["DY"],
4256 comment: "Cross compound turbine governor. Unlike tandem compound units, cross compound units are not on the same shaft.",
4257 attrs: &[
4258 AttrDef { id: "GovSteamCC.dhp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "HP damping factor (Dhp). Typical value = 0." },
4259 AttrDef { id: "GovSteamCC.dlp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "LP damping factor (Dlp). Typical value = 0." },
4260 AttrDef { id: "GovSteamCC.fhp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of HP power ahead of reheater (Fhp). Typical value = 0,3." },
4261 AttrDef { id: "GovSteamCC.flp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of LP power ahead of reheater (Flp). Typical value = 0,7." },
4262 AttrDef { id: "GovSteamCC.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
4263 AttrDef { id: "GovSteamCC.pmaxhp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum HP value position (Pmaxhp). Typical value = 1." },
4264 AttrDef { id: "GovSteamCC.pmaxlp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum LP value position (Pmaxlp). Typical value = 1." },
4265 AttrDef { id: "GovSteamCC.rhp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "HP governor droop (Rhp) (> 0). Typical value = 0,05." },
4266 AttrDef { id: "GovSteamCC.rlp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "LP governor droop (Rlp) (> 0). Typical value = 0,05." },
4267 AttrDef { id: "GovSteamCC.t1hp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "HP governor time constant (T1hp) (>= 0). Typical value = 0,1." },
4268 AttrDef { id: "GovSteamCC.t1lp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "LP governor time constant (T1lp) (>= 0). Typical value = 0,1." },
4269 AttrDef { id: "GovSteamCC.t3hp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "HP turbine time constant (T3hp) (>= 0). Typical value = 0,1." },
4270 AttrDef { id: "GovSteamCC.t3lp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "LP turbine time constant (T3lp) (>= 0). Typical value = 0,1." },
4271 AttrDef { id: "GovSteamCC.t4hp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "HP turbine time constant (T4hp) (>= 0). Typical value = 0,1." },
4272 AttrDef { id: "GovSteamCC.t4lp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "LP turbine time constant (T4lp) (>= 0). Typical value = 0,1." },
4273 AttrDef { id: "GovSteamCC.t5hp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "HP reheater time constant (T5hp) (>= 0). Typical value = 10." },
4274 AttrDef { id: "GovSteamCC.t5lp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "LP reheater time constant (T5lp) (>= 0). Typical value = 10." },
4275 ],
4276 },
4277 ClassDef {
4278 ns: "http://iec.ch/TC57/CIM100#",
4279 local: "GovSteamEU",
4280 qualified: "GovSteamEU",
4281 super_class: Some(375),
4282 concrete: true,
4283 origins: &["DY"],
4284 comment: "Simplified boiler and steam turbine with PID governor.",
4285 attrs: &[
4286 AttrDef { id: "GovSteamEU.chc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Control valves rate closing limit (Chc). Unit = PU / s. Typical value = -3,3." },
4287 AttrDef { id: "GovSteamEU.cho", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Control valves rate opening limit (Cho). Unit = PU / s. Typical value = 0,17." },
4288 AttrDef { id: "GovSteamEU.cic", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intercept valves rate closing limit (Cic). Typical value = -2,2." },
4289 AttrDef { id: "GovSteamEU.cio", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intercept valves rate opening limit (Cio). Typical value = 0,123." },
4290 AttrDef { id: "GovSteamEU.db1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Deadband of the frequency corrector (db1). Typical value = 0." },
4291 AttrDef { id: "GovSteamEU.db2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Deadband of the speed governor (db2). Typical value = 0,0004." },
4292 AttrDef { id: "GovSteamEU.hhpmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum control valve position (Hhpmax). Typical value = 1." },
4293 AttrDef { id: "GovSteamEU.ke", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain of the power controller (Ke). Typical value = 0,65." },
4294 AttrDef { id: "GovSteamEU.kfcor", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain of the frequency corrector (Kfcor). Typical value = 20." },
4295 AttrDef { id: "GovSteamEU.khp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of total turbine output generated by HP part (Khp). Typical value = 0,277." },
4296 AttrDef { id: "GovSteamEU.klp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of total turbine output generated by HP part (Klp). Typical value = 0,723." },
4297 AttrDef { id: "GovSteamEU.komegacor", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain of the speed governor (Kwcor). Typical value = 20." },
4298 AttrDef { id: "GovSteamEU.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
4299 AttrDef { id: "GovSteamEU.pmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximal active power of the turbine (Pmax). Typical value = 1." },
4300 AttrDef { id: "GovSteamEU.prhmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum low pressure limit (Prhmax). Typical value = 1,4." },
4301 AttrDef { id: "GovSteamEU.simx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intercept valves transfer limit (Simx). Typical value = 0,425." },
4302 AttrDef { id: "GovSteamEU.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Boiler time constant (Tb) (>= 0). Typical value = 100." },
4303 AttrDef { id: "GovSteamEU.tdp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Derivative time constant of the power controller (Tdp) (>= 0). Typical value = 0." },
4304 AttrDef { id: "GovSteamEU.ten", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Electro hydraulic transducer (Ten) (>= 0). Typical value = 0,1." },
4305 AttrDef { id: "GovSteamEU.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency transducer time constant (Tf) (>= 0). Typical value = 0." },
4306 AttrDef { id: "GovSteamEU.tfp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of the power controller (Tfp) (>= 0). Typical value = 0." },
4307 AttrDef { id: "GovSteamEU.thp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High pressure (HP) time constant of the turbine (Thp) (>= 0). Typical value = 0,31." },
4308 AttrDef { id: "GovSteamEU.tip", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Integral time constant of the power controller (Tip) (>= 0). Typical value = 2." },
4309 AttrDef { id: "GovSteamEU.tlp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low pressure (LP) time constant of the turbine (Tlp) (>= 0). Typical value = 0,45." },
4310 AttrDef { id: "GovSteamEU.tp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power transducer time constant (Tp) (>= 0). Typical value = 0,07." },
4311 AttrDef { id: "GovSteamEU.trh", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reheater time constant of the turbine (Trh) (>= 0). Typical value = 8." },
4312 AttrDef { id: "GovSteamEU.tvhp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Control valves servo time constant (Tvhp) (>= 0). Typical value = 0,1." },
4313 AttrDef { id: "GovSteamEU.tvip", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intercept valves servo time constant (Tvip) (>= 0). Typical value = 0,15." },
4314 AttrDef { id: "GovSteamEU.tw", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Speed transducer time constant (Tw) (>= 0). Typical value = 0,02." },
4315 AttrDef { id: "GovSteamEU.wfmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Upper limit for frequency correction (Wfmax) (> GovSteamEU.wfmin). Typical value = 0,05." },
4316 AttrDef { id: "GovSteamEU.wfmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lower limit for frequency correction (Wfmin) (< GovSteamEU.wfmax). Typical value = -0,05." },
4317 AttrDef { id: "GovSteamEU.wmax1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Emergency speed control lower limit (wmax1). Typical value = 1,025." },
4318 AttrDef { id: "GovSteamEU.wmax2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Emergency speed control upper limit (wmax2). Typical value = 1,05." },
4319 AttrDef { id: "GovSteamEU.wwmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Upper limit for the speed governor (Wwmax) (> GovSteamEU.wwmin). Typical value = 0,1." },
4320 AttrDef { id: "GovSteamEU.wwmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lower limit for the speed governor frequency correction (Wwmin) (< GovSteamEU.wwmax). Typical value = -1." },
4321 ],
4322 },
4323 ClassDef {
4324 ns: "http://iec.ch/TC57/CIM100#",
4325 local: "GovSteamFV2",
4326 qualified: "GovSteamFV2",
4327 super_class: Some(375),
4328 concrete: true,
4329 origins: &["DY"],
4330 comment: "Steam turbine governor with reheat time constants and modelling of the effects of fast valve closing to reduce mechanical power.",
4331 attrs: &[
4332 AttrDef { id: "GovSteamFV2.dt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "(Dt)." },
4333 AttrDef { id: "GovSteamFV2.k", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of the turbine power developed by turbine sections not involved in fast valving (K)." },
4334 AttrDef { id: "GovSteamFV2.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Alternate base used instead of machine base in equipment model if necessary (MWbase) (> 0). Unit = MW." },
4335 AttrDef { id: "GovSteamFV2.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "(R)." },
4336 AttrDef { id: "GovSteamFV2.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor time constant (T1) (>= 0)." },
4337 AttrDef { id: "GovSteamFV2.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reheater time constant (T3) (>= 0)." },
4338 AttrDef { id: "GovSteamFV2.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time after initial time for valve to close (Ta) (>= 0)." },
4339 AttrDef { id: "GovSteamFV2.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time after initial time for valve to begin opening (Tb) (>= 0)." },
4340 AttrDef { id: "GovSteamFV2.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time after initial time for valve to become fully open (Tc) (>= 0)." },
4341 AttrDef { id: "GovSteamFV2.tt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant with which power falls off after intercept valve closure (Tt) (>= 0)." },
4342 AttrDef { id: "GovSteamFV2.vmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "(Vmax) (> GovSteamFV2.vmin)." },
4343 AttrDef { id: "GovSteamFV2.vmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "(Vmin) (< GovSteamFV2.vmax)." },
4344 ],
4345 },
4346 ClassDef {
4347 ns: "http://iec.ch/TC57/CIM100#",
4348 local: "GovSteamFV3",
4349 qualified: "GovSteamFV3",
4350 super_class: Some(375),
4351 concrete: true,
4352 origins: &["DY"],
4353 comment: "Simplified GovSteamIEEE1 steam turbine governor with Prmax limit and fast valving.",
4354 attrs: &[
4355 AttrDef { id: "GovSteamFV3.gv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain valve position point 1 (GV1). Typical value = 0." },
4356 AttrDef { id: "GovSteamFV3.gv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain valve position point 2 (GV2). Typical value = 0,4." },
4357 AttrDef { id: "GovSteamFV3.gv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain valve position point 3 (GV3). Typical value = 0,5." },
4358 AttrDef { id: "GovSteamFV3.gv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain valve position point 4 (GV4). Typical value = 0,6." },
4359 AttrDef { id: "GovSteamFV3.gv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain valve position point 5 (GV5). Typical value = 1." },
4360 AttrDef { id: "GovSteamFV3.gv6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain valve position point 6 (GV6). Typical value = 0." },
4361 AttrDef { id: "GovSteamFV3.k", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor gain, (reciprocal of droop) (K). Typical value = 20." },
4362 AttrDef { id: "GovSteamFV3.k1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of turbine power developed after first boiler pass (K1). Typical value = 0,2." },
4363 AttrDef { id: "GovSteamFV3.k2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of turbine power developed after second boiler pass (K2). Typical value = 0,2." },
4364 AttrDef { id: "GovSteamFV3.k3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of hp turbine power developed after crossover or third boiler pass (K3). Typical value = 0,6." },
4365 AttrDef { id: "GovSteamFV3.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
4366 AttrDef { id: "GovSteamFV3.pgv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain power value point 1 (Pgv1). Typical value = 0." },
4367 AttrDef { id: "GovSteamFV3.pgv2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain power value point 2 (Pgv2). Typical value = 0,75." },
4368 AttrDef { id: "GovSteamFV3.pgv3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain power value point 3 (Pgv3). Typical value = 0,91." },
4369 AttrDef { id: "GovSteamFV3.pgv4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain power value point 4 (Pgv4). Typical value = 0,98." },
4370 AttrDef { id: "GovSteamFV3.pgv5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain power value point 5 (Pgv5). Typical value = 1." },
4371 AttrDef { id: "GovSteamFV3.pgv6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Nonlinear gain power value point 6 (Pgv6). Typical value = 0." },
4372 AttrDef { id: "GovSteamFV3.pmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum valve opening, PU of MWbase (Pmax) (> GovSteamFV3.pmin). Typical value = 1." },
4373 AttrDef { id: "GovSteamFV3.pmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum valve opening, PU of MWbase (Pmin) (< GovSteamFV3.pmax). Typical value = 0." },
4374 AttrDef { id: "GovSteamFV3.prmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Max. pressure in reheater (Prmax). Typical value = 1." },
4375 AttrDef { id: "GovSteamFV3.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor lead time constant (T1) (>= 0). Typical value = 0." },
4376 AttrDef { id: "GovSteamFV3.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor lag time constant (T2) (>= 0). Typical value = 0." },
4377 AttrDef { id: "GovSteamFV3.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Valve positioner time constant (T3) (> 0). Typical value = 0." },
4378 AttrDef { id: "GovSteamFV3.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Inlet piping/steam bowl time constant (T4) (>= 0). Typical value = 0,2." },
4379 AttrDef { id: "GovSteamFV3.t5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of second boiler pass (i.e. reheater) (T5) (> 0 if fast valving is used, otherwise >= 0). Typical value = 0,5." },
4380 AttrDef { id: "GovSteamFV3.t6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of crossover or third boiler pass (T6) (>= 0). Typical value = 10." },
4381 AttrDef { id: "GovSteamFV3.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time to close intercept valve (IV) (Ta) (>= 0). Typical value = 0,97." },
4382 AttrDef { id: "GovSteamFV3.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time until IV starts to reopen (Tb) (>= 0). Typical value = 0,98." },
4383 AttrDef { id: "GovSteamFV3.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time until IV is fully open (Tc) (>= 0). Typical value = 0,99." },
4384 AttrDef { id: "GovSteamFV3.uc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum valve closing velocity (Uc). Unit = PU / s. Typical value = -1." },
4385 AttrDef { id: "GovSteamFV3.uo", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum valve opening velocity (Uo). Unit = PU / s. Typical value = 0,1." },
4386 ],
4387 },
4388 ClassDef {
4389 ns: "http://iec.ch/TC57/CIM100#",
4390 local: "GovSteamFV4",
4391 qualified: "GovSteamFV4",
4392 super_class: Some(375),
4393 concrete: true,
4394 origins: &["DY"],
4395 comment: "Detailed electro-hydraulic governor for steam unit.",
4396 attrs: &[
4397 AttrDef { id: "GovSteamFV4.cpsmn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum value of pressure regulator output (Cpsmn). Typical value = -1." },
4398 AttrDef { id: "GovSteamFV4.cpsmx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum value of pressure regulator output (Cpsmx). Typical value = 1." },
4399 AttrDef { id: "GovSteamFV4.crmn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum value of regulator set-point (Crmn). Typical value = 0." },
4400 AttrDef { id: "GovSteamFV4.crmx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum value of regulator set-point (Crmx). Typical value = 1,2." },
4401 AttrDef { id: "GovSteamFV4.kdc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Derivative gain of pressure regulator (Kdc). Typical value = 1." },
4402 AttrDef { id: "GovSteamFV4.kf1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency bias (reciprocal of droop) (Kf1). Typical value = 20." },
4403 AttrDef { id: "GovSteamFV4.kf3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency control (reciprocal of droop) (Kf3). Typical value = 20." },
4404 AttrDef { id: "GovSteamFV4.khp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of total turbine output generated by HP part (Khp). Typical value = 0,35." },
4405 AttrDef { id: "GovSteamFV4.kic", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Integral gain of pressure regulator (Kic). Typical value = 0,0033." },
4406 AttrDef { id: "GovSteamFV4.kip", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Integral gain of pressure feedback regulator (Kip). Typical value = 0,5." },
4407 AttrDef { id: "GovSteamFV4.kit", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Integral gain of electro-hydraulic regulator (Kit). Typical value = 0,04." },
4408 AttrDef { id: "GovSteamFV4.kmp1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "First gain coefficient of intercept valves characteristic (Kmp1). Typical value = 0,5." },
4409 AttrDef { id: "GovSteamFV4.kmp2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Second gain coefficient of intercept valves characteristic (Kmp2). Typical value = 3,5." },
4410 AttrDef { id: "GovSteamFV4.kpc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Proportional gain of pressure regulator (Kpc). Typical value = 0,5." },
4411 AttrDef { id: "GovSteamFV4.kpp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Proportional gain of pressure feedback regulator (Kpp). Typical value = 1." },
4412 AttrDef { id: "GovSteamFV4.kpt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Proportional gain of electro-hydraulic regulator (Kpt). Typical value = 0,3." },
4413 AttrDef { id: "GovSteamFV4.krc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum variation of fuel flow (Krc). Typical value = 0,05." },
4414 AttrDef { id: "GovSteamFV4.ksh", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pressure loss due to flow friction in the boiler tubes (Ksh). Typical value = 0,08." },
4415 AttrDef { id: "GovSteamFV4.lpi", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum negative power error (Lpi). Typical value = -0,15." },
4416 AttrDef { id: "GovSteamFV4.lps", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum positive power error (Lps). Typical value = 0,03." },
4417 AttrDef { id: "GovSteamFV4.mnef", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lower limit for frequency correction (MNEF). Typical value = -0,05." },
4418 AttrDef { id: "GovSteamFV4.mxef", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Upper limit for frequency correction (MXEF). Typical value = 0,05." },
4419 AttrDef { id: "GovSteamFV4.pr1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "First value of pressure set point static characteristic (Pr1). Typical value = 0,2." },
4420 AttrDef { id: "GovSteamFV4.pr2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Second value of pressure set point static characteristic, corresponding to Ps0 = 1,0 PU (Pr2). Typical value = 0,75." },
4421 AttrDef { id: "GovSteamFV4.psmn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum value of pressure set point static characteristic (Psmn). Typical value = 1." },
4422 AttrDef { id: "GovSteamFV4.rsmimn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum value of integral regulator (Rsmimn). Typical value = 0." },
4423 AttrDef { id: "GovSteamFV4.rsmimx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum value of integral regulator (Rsmimx). Typical value = 1,1." },
4424 AttrDef { id: "GovSteamFV4.rvgmn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum value of integral regulator (Rvgmn). Typical value = 0." },
4425 AttrDef { id: "GovSteamFV4.rvgmx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum value of integral regulator (Rvgmx). Typical value = 1,2." },
4426 AttrDef { id: "GovSteamFV4.srmn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum valve opening (Srmn). Typical value = 0." },
4427 AttrDef { id: "GovSteamFV4.srmx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum valve opening (Srmx). Typical value = 1,1." },
4428 AttrDef { id: "GovSteamFV4.srsmp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intercept valves characteristic discontinuity point (Srsmp). Typical value = 0,43." },
4429 AttrDef { id: "GovSteamFV4.svmn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum regulator gate closing velocity (Svmn). Typical value = -0,0333." },
4430 AttrDef { id: "GovSteamFV4.svmx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum regulator gate opening velocity (Svmx). Typical value = 0,0333." },
4431 AttrDef { id: "GovSteamFV4.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Control valves rate opening time (Ta) (>= 0). Typical value = 0,8." },
4432 AttrDef { id: "GovSteamFV4.tam", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intercept valves rate opening time (Tam) (>= 0). Typical value = 0,8." },
4433 AttrDef { id: "GovSteamFV4.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Control valves rate closing time (Tc) (>= 0). Typical value = 0,5." },
4434 AttrDef { id: "GovSteamFV4.tcm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intercept valves rate closing time (Tcm) (>= 0). Typical value = 0,5." },
4435 AttrDef { id: "GovSteamFV4.tdc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Derivative time constant of pressure regulator (Tdc) (>= 0). Typical value = 90." },
4436 AttrDef { id: "GovSteamFV4.tf1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of fuel regulation (Tf1) (>= 0). Typical value = 10." },
4437 AttrDef { id: "GovSteamFV4.tf2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of steam chest (Tf2) (>= 0). Typical value = 10." },
4438 AttrDef { id: "GovSteamFV4.thp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High pressure (HP) time constant of the turbine (Thp) (>= 0). Typical value = 0,15." },
4439 AttrDef { id: "GovSteamFV4.tmp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low pressure (LP) time constant of the turbine (Tmp) (>= 0). Typical value = 0,4." },
4440 AttrDef { id: "GovSteamFV4.trh", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reheater time constant of the turbine (Trh) (>= 0). Typical value = 10." },
4441 AttrDef { id: "GovSteamFV4.tv", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Boiler time constant (Tv) (>= 0). Typical value = 60." },
4442 AttrDef { id: "GovSteamFV4.ty", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Control valves servo time constant (Ty) (>= 0). Typical value = 0,1." },
4443 AttrDef { id: "GovSteamFV4.y", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient of linearized equations of turbine (Stodola formulation) (Y). Typical value = 0,13." },
4444 AttrDef { id: "GovSteamFV4.yhpmn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum control valve position (Yhpmn). Typical value = 0." },
4445 AttrDef { id: "GovSteamFV4.yhpmx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum control valve position (Yhpmx). Typical value = 1,1." },
4446 AttrDef { id: "GovSteamFV4.ympmn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum intercept valve position (Ympmn). Typical value = 0." },
4447 AttrDef { id: "GovSteamFV4.ympmx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum intercept valve position (Ympmx). Typical value = 1,1." },
4448 ],
4449 },
4450 ClassDef {
4451 ns: "http://iec.ch/TC57/CIM100#",
4452 local: "GovSteamIEEE1",
4453 qualified: "GovSteamIEEE1",
4454 super_class: Some(375),
4455 concrete: true,
4456 origins: &["DY"],
4457 comment: "IEEE steam turbine governor model. Reference: IEEE Transactions on Power Apparatus and Systems, November/December 1973, Volume PAS-92, Number 6, Dynamic Models for Steam and Hydro Turbines in Power System Studies, page 1904.",
4458 attrs: &[
4459 AttrDef { id: "GovSteamIEEE1.k", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor gain (reciprocal of droop) (K) (> 0). Typical value = 25." },
4460 AttrDef { id: "GovSteamIEEE1.k1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of HP shaft power after first boiler pass (K1). Typical value = 0,2." },
4461 AttrDef { id: "GovSteamIEEE1.k2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of LP shaft power after first boiler pass (K2). Typical value = 0." },
4462 AttrDef { id: "GovSteamIEEE1.k3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of HP shaft power after second boiler pass (K3). Typical value = 0,3." },
4463 AttrDef { id: "GovSteamIEEE1.k4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of LP shaft power after second boiler pass (K4). Typical value = 0." },
4464 AttrDef { id: "GovSteamIEEE1.k5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of HP shaft power after third boiler pass (K5). Typical value = 0,5." },
4465 AttrDef { id: "GovSteamIEEE1.k6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of LP shaft power after third boiler pass (K6). Typical value = 0." },
4466 AttrDef { id: "GovSteamIEEE1.k7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of HP shaft power after fourth boiler pass (K7). Typical value = 0." },
4467 AttrDef { id: "GovSteamIEEE1.k8", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of LP shaft power after fourth boiler pass (K8). Typical value = 0." },
4468 AttrDef { id: "GovSteamIEEE1.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
4469 AttrDef { id: "GovSteamIEEE1.pmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum valve opening (Pmax) (> GovSteamIEEE1.pmin). Typical value = 1." },
4470 AttrDef { id: "GovSteamIEEE1.pmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum valve opening (Pmin) (>= 0 and < GovSteamIEEE1.pmax). Typical value = 0." },
4471 AttrDef { id: "GovSteamIEEE1.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor lag time constant (T1) (>= 0). Typical value = 0." },
4472 AttrDef { id: "GovSteamIEEE1.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor lead time constant (T2) (>= 0). Typical value = 0." },
4473 AttrDef { id: "GovSteamIEEE1.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Valve positioner time constant (T3) (> 0). Typical value = 0,1." },
4474 AttrDef { id: "GovSteamIEEE1.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Inlet piping/steam bowl time constant (T4) (>= 0). Typical value = 0,3." },
4475 AttrDef { id: "GovSteamIEEE1.t5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of second boiler pass (T5) (>= 0). Typical value = 5." },
4476 AttrDef { id: "GovSteamIEEE1.t6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of third boiler pass (T6) (>= 0). Typical value = 0,5." },
4477 AttrDef { id: "GovSteamIEEE1.t7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of fourth boiler pass (T7) (>= 0). Typical value = 0." },
4478 AttrDef { id: "GovSteamIEEE1.uc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum valve closing velocity (Uc) (< 0). Unit = PU / s. Typical value = -10." },
4479 AttrDef { id: "GovSteamIEEE1.uo", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum valve opening velocity (Uo) (> 0). Unit = PU / s. Typical value = 1." },
4480 ],
4481 },
4482 ClassDef {
4483 ns: "http://iec.ch/TC57/CIM100#",
4484 local: "GovSteamSGO",
4485 qualified: "GovSteamSGO",
4486 super_class: Some(375),
4487 concrete: true,
4488 origins: &["DY"],
4489 comment: "Simplified steam turbine governor.",
4490 attrs: &[
4491 AttrDef { id: "GovSteamSGO.k1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "One / PU regulation (K1)." },
4492 AttrDef { id: "GovSteamSGO.k2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction (K2)." },
4493 AttrDef { id: "GovSteamSGO.k3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction (K3)." },
4494 AttrDef { id: "GovSteamSGO.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
4495 AttrDef { id: "GovSteamSGO.pmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Upper power limit (Pmax) (> GovSteamSGO.pmin)." },
4496 AttrDef { id: "GovSteamSGO.pmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lower power limit (Pmin) (>= 0 and < GovSteamSGO.pmax)." },
4497 AttrDef { id: "GovSteamSGO.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Controller lag (T1) (>= 0)." },
4498 AttrDef { id: "GovSteamSGO.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Controller lead compensation (T2) (>= 0)." },
4499 AttrDef { id: "GovSteamSGO.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Governor lag (T3) (> 0)." },
4500 AttrDef { id: "GovSteamSGO.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Delay due to steam inlet volumes associated with steam chest and inlet piping (T4) (>= 0)." },
4501 AttrDef { id: "GovSteamSGO.t5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reheater delay including hot and cold leads (T5) (>= 0)." },
4502 AttrDef { id: "GovSteamSGO.t6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Delay due to IP-LP turbine, crossover pipes and LP end hoods (T6) (>= 0)." },
4503 ],
4504 },
4505 ClassDef {
4506 ns: "http://iec.ch/TC57/CIM100#",
4507 local: "GrossToNetActivePowerCurve",
4508 qualified: "GrossToNetActivePowerCurve",
4509 super_class: Some(53),
4510 concrete: true,
4511 origins: &["EQ"],
4512 comment: "Relationship between the generating unit's gross active power output on the X-axis (measured at the terminals of the machine(s)) and the generating unit's net active power output on the Y-axis (based on utility-defined measurements at the power station). Station service loads, when modelled, should be treated as non-conforming bus loads. There may be more than one curve, depending on the auxiliary equipment that is in service.",
4513 attrs: &[
4514 AttrDef { id: "GrossToNetActivePowerCurve.GeneratingUnit", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "GeneratingUnit", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "A generating unit may have a gross active power to net active power curve, describing the losses and auxiliary power requirements of the unit." },
4515 ],
4516 },
4517 ClassDef {
4518 ns: "http://iec.ch/TC57/CIM100#",
4519 local: "Ground",
4520 qualified: "Ground",
4521 super_class: Some(37),
4522 concrete: true,
4523 origins: &["EQ"],
4524 comment: "A point where the system is grounded used for connecting conducting equipment to ground. The power system model can have any number of grounds.",
4525 attrs: &[],
4526 },
4527 ClassDef {
4528 ns: "http://iec.ch/TC57/CIM100#",
4529 local: "GroundDisconnector",
4530 qualified: "GroundDisconnector",
4531 super_class: Some(353),
4532 concrete: true,
4533 origins: &["EQ", "SSH"],
4534 comment: "A manually operated or motor operated mechanical switching device used for isolating a circuit or equipment from ground.",
4535 attrs: &[],
4536 },
4537 ClassDef {
4538 ns: "http://iec.ch/TC57/CIM100#",
4539 local: "GroundingImpedance",
4540 qualified: "GroundingImpedance",
4541 super_class: Some(92),
4542 concrete: true,
4543 origins: &["EQ", "SC"],
4544 comment: "A fixed impedance device used for grounding.",
4545 attrs: &[
4546 AttrDef { id: "GroundingImpedance.x", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Reactance of device." },
4547 ],
4548 },
4549 ClassDef {
4550 ns: "http://iec.ch/TC57/CIM100#",
4551 local: "HVDCDynamics",
4552 qualified: "HVDCDynamics",
4553 super_class: Some(91),
4554 concrete: false,
4555 origins: &["DY"],
4556 comment: "HVDC whose behaviour is described by reference to a standard model or by definition of a user-defined model.",
4557 attrs: &[],
4558 },
4559 ClassDef {
4560 ns: "http://iec.ch/TC57/CIM100#",
4561 local: "HydroGeneratingUnit",
4562 qualified: "HydroGeneratingUnit",
4563 super_class: Some(169),
4564 concrete: true,
4565 origins: &["EQ", "SSH"],
4566 comment: "A generating unit whose prime mover is a hydraulic turbine (e.g., Francis, Pelton, Kaplan).",
4567 attrs: &[
4568 AttrDef { id: "HydroGeneratingUnit.HydroPowerPlant", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "HydroPowerPlant", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The hydro generating unit belongs to a hydro power plant." },
4569 AttrDef { id: "HydroGeneratingUnit.dropHeight", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Length", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The height water drops from the reservoir mid-point to the turbine." },
4570 AttrDef { id: "HydroGeneratingUnit.energyConversionCapability", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "HydroEnergyConversionKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "Energy conversion capability for generating." },
4571 AttrDef { id: "HydroGeneratingUnit.turbineType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "HydroTurbineKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "Type of turbine." },
4572 ],
4573 },
4574 ClassDef {
4575 ns: "http://iec.ch/TC57/CIM100#",
4576 local: "HydroPowerPlant",
4577 qualified: "HydroPowerPlant",
4578 super_class: Some(282),
4579 concrete: true,
4580 origins: &["EQ"],
4581 comment: "A hydro power station which can generate or pump. When generating, the generator turbines receive water from an upper reservoir. When pumping, the pumps receive their water from a lower reservoir.",
4582 attrs: &[
4583 AttrDef { id: "HydroPowerPlant.HydroGeneratingUnits", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "HydroGeneratingUnit", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The hydro generating unit belongs to a hydro power plant." },
4584 AttrDef { id: "HydroPowerPlant.HydroPumps", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "HydroPump", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The hydro pump may be a member of a pumped storage plant or a pump for distributing water." },
4585 AttrDef { id: "HydroPowerPlant.hydroPlantStorageType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "HydroPlantStorageKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "The type of hydro power plant water storage." },
4586 ],
4587 },
4588 ClassDef {
4589 ns: "http://iec.ch/TC57/CIM100#",
4590 local: "HydroPump",
4591 qualified: "HydroPump",
4592 super_class: Some(98),
4593 concrete: true,
4594 origins: &["EQ"],
4595 comment: "A synchronous motor-driven pump, typically associated with a pumped storage plant.",
4596 attrs: &[
4597 AttrDef { id: "HydroPump.HydroPowerPlant", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "HydroPowerPlant", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The hydro pump may be a member of a pumped storage plant or a pump for distributing water." },
4598 AttrDef { id: "HydroPump.RotatingMachine", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RotatingMachine", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The synchronous machine drives the turbine which moves the water from a low elevation to a higher elevation. The direction of machine rotation for pumping may or may not be the same as for generating." },
4599 ],
4600 },
4601 ClassDef {
4602 ns: "http://iec.ch/TC57/CIM100#",
4603 local: "IOPoint",
4604 qualified: "IOPoint",
4605 super_class: Some(213),
4606 concrete: false,
4607 origins: &["OP"],
4608 comment: "The class describe a measurement or control value. The purpose is to enable having attributes and associations common for measurement and control.",
4609 attrs: &[],
4610 },
4611 ClassDef {
4612 ns: "http://iec.ch/TC57/CIM100#",
4613 local: "IdentifiedObject",
4614 qualified: "IdentifiedObject",
4615 super_class: None,
4616 concrete: false,
4617 origins: &["EQ", "DL", "DY", "EQBD", "GL", "OP", "SC", "SSH", "SV", "TP"],
4618 comment: "This is a root class to provide common identification for all classes needing identification and naming attributes.",
4619 attrs: &[
4620 AttrDef { id: "IdentifiedObject.DiagramObjects", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DiagramObject", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DL"], comment: "The diagram objects that are associated with the domain object." },
4621 AttrDef { id: "IdentifiedObject.description", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["EQ", "DL", "DY", "EQBD", "OP", "TP"], comment: "The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy." },
4622 AttrDef { id: "IdentifiedObject.energyIdentCodeEic", ns: "http://iec.ch/TC57/CIM100-European#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["EQ", "EQBD", "TP"], comment: "The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site." },
4623 AttrDef { id: "IdentifiedObject.mRID", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["EQ", "DL", "DY", "EQBD", "GL", "OP", "SC", "SSH", "SV", "TP"], comment: "Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements." },
4624 AttrDef { id: "IdentifiedObject.name", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["EQ", "DL", "DY", "EQBD", "GL", "OP", "SV", "TP"], comment: "The name is any free human readable and possibly non unique text naming the object." },
4625 AttrDef { id: "IdentifiedObject.shortName", ns: "http://iec.ch/TC57/CIM100-European#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["EQ", "EQBD", "TP"], comment: "The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum." },
4626 ],
4627 },
4628 ClassDef {
4629 ns: "http://iec.ch/TC57/CIM100#",
4630 local: "Jumper",
4631 qualified: "Jumper",
4632 super_class: Some(353),
4633 concrete: true,
4634 origins: &["EQ", "SSH"],
4635 comment: "A short section of conductor with negligible impedance which can be manually removed and replaced if the circuit is de-energized. Note that zero-impedance branches can potentially be modelled by other equipment types.",
4636 attrs: &[],
4637 },
4638 ClassDef {
4639 ns: "http://iec.ch/TC57/CIM100#",
4640 local: "Junction",
4641 qualified: "Junction",
4642 super_class: Some(44),
4643 concrete: true,
4644 origins: &["EQ", "EQBD"],
4645 comment: "A point where one or more conducting equipments are connected with zero resistance.",
4646 attrs: &[],
4647 },
4648 ClassDef {
4649 ns: "http://iec.ch/TC57/CIM100#",
4650 local: "Limit",
4651 qualified: "Limit",
4652 super_class: Some(213),
4653 concrete: false,
4654 origins: &["OP"],
4655 comment: "Specifies one limit value for a Measurement. A Measurement typically has several limits that are kept together by the LimitSet class. The actual meaning and use of a Limit instance (i.e., if it is an alarm or warning limit or if it is a high or low limit) is not captured in the Limit class. However the name of a Limit instance may indicate both meaning and use.",
4656 attrs: &[],
4657 },
4658 ClassDef {
4659 ns: "http://iec.ch/TC57/CIM100-European#",
4660 local: "LimitKind",
4661 qualified: "LimitKind",
4662 super_class: None,
4663 concrete: false,
4664 origins: &["EQ"],
4665 comment: "Limit kinds.",
4666 attrs: &[],
4667 },
4668 ClassDef {
4669 ns: "http://iec.ch/TC57/CIM100#",
4670 local: "LimitSet",
4671 qualified: "LimitSet",
4672 super_class: Some(213),
4673 concrete: false,
4674 origins: &["OP"],
4675 comment: "Specifies a set of Limits that are associated with a Measurement. A Measurement may have several LimitSets corresponding to seasonal or other changing conditions. The condition is captured in the name and description attributes. The same LimitSet may be used for several Measurements. In particular percentage limits are used this way.",
4676 attrs: &[
4677 AttrDef { id: "LimitSet.isPercentageLimits", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["OP"], comment: "Tells if the limit values are in percentage of normalValue or the specified Unit for Measurements and Controls." },
4678 ],
4679 },
4680 ClassDef {
4681 ns: "http://iec.ch/TC57/CIM100#",
4682 local: "Line",
4683 qualified: "Line",
4684 super_class: Some(99),
4685 concrete: true,
4686 origins: &["EQ", "EQBD"],
4687 comment: "Contains equipment beyond a substation belonging to a power transmission line.",
4688 attrs: &[
4689 AttrDef { id: "Line.Region", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SubGeographicalRegion", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "The sub-geographical region of the line." },
4690 ],
4691 },
4692 ClassDef {
4693 ns: "http://iec.ch/TC57/CIM100#",
4694 local: "LinearShuntCompensator",
4695 qualified: "LinearShuntCompensator",
4696 super_class: Some(330),
4697 concrete: true,
4698 origins: &["EQ", "SC", "SSH"],
4699 comment: "A linear shunt compensator has banks or sections with equal admittance values.",
4700 attrs: &[
4701 AttrDef { id: "LinearShuntCompensator.b0PerSection", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Susceptance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence shunt (charging) susceptance per section." },
4702 AttrDef { id: "LinearShuntCompensator.bPerSection", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Susceptance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Positive sequence shunt (charging) susceptance per section." },
4703 AttrDef { id: "LinearShuntCompensator.g0PerSection", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Conductance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence shunt (charging) conductance per section." },
4704 AttrDef { id: "LinearShuntCompensator.gPerSection", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Conductance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Positive sequence shunt (charging) conductance per section." },
4705 ],
4706 },
4707 ClassDef {
4708 ns: "http://iec.ch/TC57/CIM100#",
4709 local: "LoadAggregate",
4710 qualified: "LoadAggregate",
4711 super_class: Some(225),
4712 concrete: true,
4713 origins: &["DY"],
4714 comment: "Aggregate loads are used to represent all or part of the real and reactive load from one or more loads in the static (power flow) data. This load is usually the aggregation of many individual load devices and the load model is an approximate representation of the aggregate response of the load devices to system disturbances. Standard aggregate load model comprised of static and/or dynamic components. A static load model represents the sensitivity of the real and reactive power consumed by the load to the amplitude and frequency of the bus voltage. A dynamic load model can be used to represent the aggregate response of the motor components of the load.",
4715 attrs: &[
4716 AttrDef { id: "LoadAggregate.LoadMotor", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "LoadMotor", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Aggregate motor (dynamic) load associated with this aggregate load." },
4717 AttrDef { id: "LoadAggregate.LoadStatic", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "LoadStatic", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Aggregate static load associated with this aggregate load." },
4718 ],
4719 },
4720 ClassDef {
4721 ns: "http://iec.ch/TC57/CIM100#",
4722 local: "LoadArea",
4723 qualified: "LoadArea",
4724 super_class: Some(93),
4725 concrete: true,
4726 origins: &["EQ"],
4727 comment: "The class is the root or first level in a hierarchical structure for grouping of loads for the purpose of load flow load scaling.",
4728 attrs: &[
4729 AttrDef { id: "LoadArea.SubLoadAreas", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SubLoadArea", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The SubLoadAreas in the LoadArea." },
4730 ],
4731 },
4732 ClassDef {
4733 ns: "http://iec.ch/TC57/CIM100#",
4734 local: "LoadBreakSwitch",
4735 qualified: "LoadBreakSwitch",
4736 super_class: Some(288),
4737 concrete: true,
4738 origins: &["EQ", "SSH"],
4739 comment: "A mechanical switching device capable of making, carrying, and breaking currents under normal operating conditions.",
4740 attrs: &[],
4741 },
4742 ClassDef {
4743 ns: "http://iec.ch/TC57/CIM100#",
4744 local: "LoadComposite",
4745 qualified: "LoadComposite",
4746 super_class: Some(225),
4747 concrete: true,
4748 origins: &["DY"],
4749 comment: "Combined static load and induction motor load effects. The dynamics of the motor are simplified by linearizing the induction machine equations.",
4750 attrs: &[
4751 AttrDef { id: "LoadComposite.epfd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Active load-frequency dependence index (dynamic) (Epfd). Typical value = 1,5." },
4752 AttrDef { id: "LoadComposite.epfs", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Active load-frequency dependence index (static) (Epfs). Typical value = 1,5." },
4753 AttrDef { id: "LoadComposite.epvd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Active load-voltage dependence index (dynamic) (Epvd). Typical value = 0,7." },
4754 AttrDef { id: "LoadComposite.epvs", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Active load-voltage dependence index (static) (Epvs). Typical value = 0,7." },
4755 AttrDef { id: "LoadComposite.eqfd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive load-frequency dependence index (dynamic) (Eqfd). Typical value = 0." },
4756 AttrDef { id: "LoadComposite.eqfs", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive load-frequency dependence index (static) (Eqfs). Typical value = 0." },
4757 AttrDef { id: "LoadComposite.eqvd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive load-voltage dependence index (dynamic) (Eqvd). Typical value = 2." },
4758 AttrDef { id: "LoadComposite.eqvs", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive load-voltage dependence index (static) (Eqvs). Typical value = 2." },
4759 AttrDef { id: "LoadComposite.h", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Inertia constant (H) (>= 0). Typical value = 2,5." },
4760 AttrDef { id: "LoadComposite.lfac", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Loading factor (Lfac). The ratio of initial P to motor MVA base. Typical value = 0,8." },
4761 AttrDef { id: "LoadComposite.pfrac", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of constant-power load to be represented by this motor model (PFRAC) (>= 0,0 and <= 1,0). Typical value = 0,5." },
4762 ],
4763 },
4764 ClassDef {
4765 ns: "http://iec.ch/TC57/CIM100#",
4766 local: "LoadDynamics",
4767 qualified: "LoadDynamics",
4768 super_class: Some(213),
4769 concrete: false,
4770 origins: &["DY"],
4771 comment: "Load whose behaviour is described by reference to a standard model or by definition of a user-defined model. A standard feature of dynamic load behaviour modelling is the ability to associate the same behaviour to multiple energy consumers by means of a single load definition. The load model is always applied to individual bus loads (energy consumers).",
4772 attrs: &[
4773 AttrDef { id: "LoadDynamics.EnergyConsumer", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "EnergyConsumer", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Energy consumer to which this dynamics load model applies." },
4774 ],
4775 },
4776 ClassDef {
4777 ns: "http://iec.ch/TC57/CIM100#",
4778 local: "LoadGenericNonLinear",
4779 qualified: "LoadGenericNonLinear",
4780 super_class: Some(225),
4781 concrete: true,
4782 origins: &["DY"],
4783 comment: "Generic non-linear dynamic (GNLD) load. This model can be used in mid-term and long-term voltage stability simulations (i.e., to study voltage collapse), as it can replace a more detailed representation of aggregate load, including induction motors, thermostatically controlled and static loads.",
4784 attrs: &[
4785 AttrDef { id: "LoadGenericNonLinear.bs", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Steady state voltage index for reactive power (BS)." },
4786 AttrDef { id: "LoadGenericNonLinear.bt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Transient voltage index for reactive power (BT)." },
4787 AttrDef { id: "LoadGenericNonLinear.genericNonLinearLoadModelType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "GenericNonLinearLoadModelKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Type of generic non-linear load model." },
4788 AttrDef { id: "LoadGenericNonLinear.ls", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Steady state voltage index for active power (LS)." },
4789 AttrDef { id: "LoadGenericNonLinear.lt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Transient voltage index for active power (LT)." },
4790 AttrDef { id: "LoadGenericNonLinear.tp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of lag function of active power (TP) (> 0)." },
4791 AttrDef { id: "LoadGenericNonLinear.tq", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant of lag function of reactive power (TQ) (> 0)." },
4792 ],
4793 },
4794 ClassDef {
4795 ns: "http://iec.ch/TC57/CIM100#",
4796 local: "LoadGroup",
4797 qualified: "LoadGroup",
4798 super_class: Some(213),
4799 concrete: false,
4800 origins: &["EQ"],
4801 comment: "The class is the third level in a hierarchical structure for grouping of loads for the purpose of load flow load scaling.",
4802 attrs: &[
4803 AttrDef { id: "LoadGroup.SubLoadArea", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SubLoadArea", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The SubLoadArea where the Loadgroup belongs." },
4804 ],
4805 },
4806 ClassDef {
4807 ns: "http://iec.ch/TC57/CIM100#",
4808 local: "LoadMotor",
4809 qualified: "LoadMotor",
4810 super_class: Some(213),
4811 concrete: true,
4812 origins: &["DY"],
4813 comment: "Aggregate induction motor load. This model is used to represent a fraction of an ordinary load as 'induction motor load'. It allows a load that is treated as an ordinary constant power in power flow analysis to be represented by an induction motor in dynamic simulation. This model is intended for representation of aggregations of many motors dispersed through a load represented at a high voltage bus but where there is no information on the characteristics of individual motors. Either a 'one-cage' or 'two-cage' model of the induction machine can be modelled. Magnetic saturation is not modelled. This model treats a fraction of the constant power part of a load as a motor. During initialisation, the initial power drawn by the motor is set equal to Pfrac times the constant P part of the static load. The remainder of the load is left as a static load. The reactive power demand of the motor is calculated during initialisation as a function of voltage at the load bus. This reactive power demand can be less than or greater than the constant Q component of the load. If the motor's reactive demand is greater than the constant Q component of the load, the model inserts a shunt capacitor at the terminal of the motor to bring its reactive demand down to equal the constant Q reactive load. If an induction motor load model and a static load model are both present for a load, the motor Pfrac is assumed to be subtracted from the power flow constant P load before the static load model is applied. The remainder of the load, if any, is then represented by the static load model.",
4814 attrs: &[
4815 AttrDef { id: "LoadMotor.LoadAggregate", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "LoadAggregate", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Aggregate load to which this aggregate motor (dynamic) load belongs." },
4816 AttrDef { id: "LoadMotor.d", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Damping factor (D). Unit = delta P/delta speed. Typical value = 2." },
4817 AttrDef { id: "LoadMotor.h", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Inertia constant (H) (>= 0). Typical value = 0,4." },
4818 AttrDef { id: "LoadMotor.lfac", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Loading factor (Lfac). The ratio of initial P to motor MVA base. Typical value = 0,8." },
4819 AttrDef { id: "LoadMotor.lp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Transient reactance (Lp). Typical value = 0,15." },
4820 AttrDef { id: "LoadMotor.lpp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Subtransient reactance (Lpp). Typical value = 0,15." },
4821 AttrDef { id: "LoadMotor.ls", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Synchronous reactance (Ls). Typical value = 3,2." },
4822 AttrDef { id: "LoadMotor.pfrac", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Fraction of constant-power load to be represented by this motor model (Pfrac) (>= 0,0 and <= 1,0). Typical value = 0,3." },
4823 AttrDef { id: "LoadMotor.ra", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stator resistance (Ra). Typical value = 0." },
4824 AttrDef { id: "LoadMotor.tbkr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Circuit breaker operating time (Tbkr) (>= 0). Typical value = 0,08." },
4825 AttrDef { id: "LoadMotor.tpo", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Transient rotor time constant (Tpo) (>= 0). Typical value = 1." },
4826 AttrDef { id: "LoadMotor.tppo", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Subtransient rotor time constant (Tppo) (>= 0). Typical value = 0,02." },
4827 AttrDef { id: "LoadMotor.tv", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage trip pickup time (Tv) (>= 0). Typical value = 0,1." },
4828 AttrDef { id: "LoadMotor.vt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage threshold for tripping (Vt). Typical value = 0,7." },
4829 ],
4830 },
4831 ClassDef {
4832 ns: "http://iec.ch/TC57/CIM100#",
4833 local: "LoadResponseCharacteristic",
4834 qualified: "LoadResponseCharacteristic",
4835 super_class: Some(213),
4836 concrete: true,
4837 origins: &["EQ"],
4838 comment: "Models the characteristic response of the load demand due to changes in system conditions such as voltage and frequency. It is not related to demand response. If LoadResponseCharacteristic.exponentModel is True, the exponential voltage or frequency dependent models are specified and used as to calculate active and reactive power components of the load model. The equations to calculate active and reactive power components of the load model are internal to the power flow calculation, hence they use different quantities depending on the use case of the data exchange. The equations for exponential voltage dependent load model injected power are: pInjection= Pnominal* (Voltage/cim:BaseVoltage.nominalVoltage) ** cim:LoadResponseCharacteristic.pVoltageExponent qInjection= Qnominal* (Voltage/cim:BaseVoltage.nominalVoltage) ** cim:LoadResponseCharacteristic.qVoltageExponent Where: 1) * means 'multiply' and ** is 'raised to power of'; 2) Pnominal and Qnominal represent the active power and reactive power at nominal voltage as any load described by the voltage exponential model shall be given at nominal voltage. This means that EnergyConsumer.p and EnergyConsumer.q are at nominal voltage. 3) After power flow is solved: -pInjection and qInjection correspond to SvPowerflow.p and SvPowerflow.q respectively. - Voltage corresponds to SvVoltage.v at the TopologicalNode where the load is connected.",
4839 attrs: &[
4840 AttrDef { id: "LoadResponseCharacteristic.EnergyConsumer", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "EnergyConsumer", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The set of loads that have the response characteristics." },
4841 AttrDef { id: "LoadResponseCharacteristic.exponentModel", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["EQ"], comment: "Indicates the exponential voltage dependency model is to be used. If false, the coefficient model is to be used. The exponential voltage dependency model consist of the attributes: - pVoltageExponent - qVoltageExponent - pFrequencyExponent - qFrequencyExponent. The coefficient model consist of the attributes: - pConstantImpedance - pConstantCurrent - pConstantPower - qConstantImpedance - qConstantCurrent - qConstantPower. The sum of pConstantImpedance, pConstantCurrent and pConstantPower shall equal 1. The sum of qConstantImpedance, qConstantCurrent and qConstantPower shall equal 1." },
4842 AttrDef { id: "LoadResponseCharacteristic.pConstantCurrent", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Portion of active power load modelled as constant current." },
4843 AttrDef { id: "LoadResponseCharacteristic.pConstantImpedance", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Portion of active power load modelled as constant impedance." },
4844 AttrDef { id: "LoadResponseCharacteristic.pConstantPower", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Portion of active power load modelled as constant power." },
4845 AttrDef { id: "LoadResponseCharacteristic.pFrequencyExponent", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Exponent of per unit frequency effecting active power." },
4846 AttrDef { id: "LoadResponseCharacteristic.pVoltageExponent", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Exponent of per unit voltage effecting real power." },
4847 AttrDef { id: "LoadResponseCharacteristic.qConstantCurrent", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Portion of reactive power load modelled as constant current." },
4848 AttrDef { id: "LoadResponseCharacteristic.qConstantImpedance", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Portion of reactive power load modelled as constant impedance." },
4849 AttrDef { id: "LoadResponseCharacteristic.qConstantPower", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Portion of reactive power load modelled as constant power." },
4850 AttrDef { id: "LoadResponseCharacteristic.qFrequencyExponent", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Exponent of per unit frequency effecting reactive power." },
4851 AttrDef { id: "LoadResponseCharacteristic.qVoltageExponent", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Exponent of per unit voltage effecting reactive power." },
4852 ],
4853 },
4854 ClassDef {
4855 ns: "http://iec.ch/TC57/CIM100#",
4856 local: "LoadStatic",
4857 qualified: "LoadStatic",
4858 super_class: Some(213),
4859 concrete: true,
4860 origins: &["DY"],
4861 comment: "General static load. This model represents the sensitivity of the real and reactive power consumed by the load to the amplitude and frequency of the bus voltage.",
4862 attrs: &[
4863 AttrDef { id: "LoadStatic.LoadAggregate", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "LoadAggregate", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Aggregate load to which this aggregate static load belongs." },
4864 AttrDef { id: "LoadStatic.ep1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "First term voltage exponent for active power (Ep1). Used only when .staticLoadModelType = exponential." },
4865 AttrDef { id: "LoadStatic.ep2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Second term voltage exponent for active power (Ep2). Used only when .staticLoadModelType = exponential." },
4866 AttrDef { id: "LoadStatic.ep3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Third term voltage exponent for active power (Ep3). Used only when .staticLoadModelType = exponential." },
4867 AttrDef { id: "LoadStatic.eq1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "First term voltage exponent for reactive power (Eq1). Used only when .staticLoadModelType = exponential." },
4868 AttrDef { id: "LoadStatic.eq2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Second term voltage exponent for reactive power (Eq2). Used only when .staticLoadModelType = exponential." },
4869 AttrDef { id: "LoadStatic.eq3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Third term voltage exponent for reactive power (Eq3). Used only when .staticLoadModelType = exponential." },
4870 AttrDef { id: "LoadStatic.kp1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "First term voltage coefficient for active power (Kp1). Not used when .staticLoadModelType = constantZ." },
4871 AttrDef { id: "LoadStatic.kp2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Second term voltage coefficient for active power (Kp2). Not used when .staticLoadModelType = constantZ." },
4872 AttrDef { id: "LoadStatic.kp3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Third term voltage coefficient for active power (Kp3). Not used when .staticLoadModelType = constantZ." },
4873 AttrDef { id: "LoadStatic.kp4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency coefficient for active power (Kp4) (not = 0 if .staticLoadModelType = zIP2). Used only when .staticLoadModelType = zIP2." },
4874 AttrDef { id: "LoadStatic.kpf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency deviation coefficient for active power (Kpf). Not used when .staticLoadModelType = constantZ." },
4875 AttrDef { id: "LoadStatic.kq1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "First term voltage coefficient for reactive power (Kq1). Not used when .staticLoadModelType = constantZ." },
4876 AttrDef { id: "LoadStatic.kq2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Second term voltage coefficient for reactive power (Kq2). Not used when .staticLoadModelType = constantZ." },
4877 AttrDef { id: "LoadStatic.kq3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Third term voltage coefficient for reactive power (Kq3). Not used when .staticLoadModelType = constantZ." },
4878 AttrDef { id: "LoadStatic.kq4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency coefficient for reactive power (Kq4) (not = 0 when .staticLoadModelType = zIP2). Used only when .staticLoadModelType - zIP2." },
4879 AttrDef { id: "LoadStatic.kqf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency deviation coefficient for reactive power (Kqf). Not used when .staticLoadModelType = constantZ." },
4880 AttrDef { id: "LoadStatic.staticLoadModelType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "StaticLoadModelKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Type of static load model. Typical value = constantZ." },
4881 ],
4882 },
4883 ClassDef {
4884 ns: "http://iec.ch/TC57/CIM100#",
4885 local: "LoadUserDefined",
4886 qualified: "LoadUserDefined",
4887 super_class: Some(225),
4888 concrete: true,
4889 origins: &["DY"],
4890 comment: "Load whose dynamic behaviour is described by a user-defined model.",
4891 attrs: &[
4892 AttrDef { id: "LoadUserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
4893 AttrDef { id: "LoadUserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
4894 ],
4895 },
4896 ClassDef {
4897 ns: "http://iec.ch/TC57/CIM100#",
4898 local: "Location",
4899 qualified: "Location",
4900 super_class: Some(213),
4901 concrete: true,
4902 origins: &["GL"],
4903 comment: "The place, scene, or point of something where someone or something has been, is, and/or will be at a given moment in time. It can be defined with one or more position points (coordinates) in a given coordinate system.",
4904 attrs: &[
4905 AttrDef { id: "Location.CoordinateSystem", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "CoordinateSystem", is_list: false, used: true, xsd: "", value_ns: "", origins: &["GL"], comment: "Coordinate system used to describe position points of this location." },
4906 AttrDef { id: "Location.PositionPoints", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PositionPoint", is_list: true, used: false, xsd: "", value_ns: "", origins: &["GL"], comment: "Sequence of position points describing this location, expressed in coordinate system 'Location.CoordinateSystem'." },
4907 AttrDef { id: "Location.PowerSystemResources", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PowerSystemResource", is_list: false, used: true, xsd: "", value_ns: "", origins: &["GL"], comment: "All power system resources at this location." },
4908 AttrDef { id: "Location.mainAddress", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "StreetAddress", is_list: false, used: true, xsd: "", value_ns: "", origins: &["GL"], comment: "Main address of the location." },
4909 ],
4910 },
4911 ClassDef {
4912 ns: "http://iec.ch/TC57/CIM100#",
4913 local: "Measurement",
4914 qualified: "Measurement",
4915 super_class: Some(213),
4916 concrete: false,
4917 origins: &["OP"],
4918 comment: "A Measurement represents any measured, calculated or non-measured non-calculated quantity. Any piece of equipment may contain Measurements, e.g. a substation may have temperature measurements and door open indications, a transformer may have oil temperature and tank pressure measurements, a bay may contain a number of power flow measurements and a Breaker may contain a switch status measurement. The PSR - Measurement association is intended to capture this use of Measurement and is included in the naming hierarchy based on EquipmentContainer. The naming hierarchy typically has Measurements as leaves, e.g. Substation-VoltageLevel-Bay-Switch-Measurement. Some Measurements represent quantities related to a particular sensor location in the network, e.g. a voltage transformer (VT) or potential transformer (PT) at a busbar or a current transformer (CT) at the bar between a breaker and an isolator. The sensing position is not captured in the PSR - Measurement association. Instead it is captured by the Measurement - Terminal association that is used to define the sensing location in the network topology. The location is defined by the connection of the Terminal to ConductingEquipment. If both a Terminal and PSR are associated, and the PSR is of type ConductingEquipment, the associated Terminal should belong to that ConductingEquipment instance. When the sensor location is needed both Measurement-PSR and Measurement-Terminal are used. The Measurement-Terminal association is never used alone.",
4919 attrs: &[
4920 AttrDef { id: "Measurement.PowerSystemResource", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PowerSystemResource", is_list: false, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "The power system resource that contains the measurement." },
4921 AttrDef { id: "Measurement.Terminal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ACDCTerminal", is_list: false, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "One or more measurements may be associated with a terminal in the network." },
4922 AttrDef { id: "Measurement.measurementType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["OP"], comment: "Specifies the type of measurement. For example, this specifies if the measurement represents an indoor temperature, outdoor temperature, bus voltage, line flow, etc. When the measurementType is set to 'Specialization', the type of Measurement is defined in more detail by the specialized class which inherits from Measurement." },
4923 AttrDef { id: "Measurement.phases", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "PhaseCode", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["OP"], comment: "Indicates to which phases the measurement applies and avoids the need to use 'measurementType' to also encode phase information (which would explode the types). The phase information in Measurement, along with 'measurementType' and 'phases' uniquely defines a Measurement for a device, based on normal network phase. Their meaning will not change when the computed energizing phasing is changed due to jumpers or other reasons. If the attribute is missing three phases (ABC) shall be assumed." },
4924 AttrDef { id: "Measurement.unitMultiplier", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "UnitMultiplier", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["OP"], comment: "The unit multiplier of the measured quantity." },
4925 AttrDef { id: "Measurement.unitSymbol", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "UnitSymbol", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["OP"], comment: "The unit of measure of the measured quantity." },
4926 ],
4927 },
4928 ClassDef {
4929 ns: "http://iec.ch/TC57/CIM100#",
4930 local: "MeasurementValue",
4931 qualified: "MeasurementValue",
4932 super_class: Some(212),
4933 concrete: false,
4934 origins: &["OP"],
4935 comment: "The current state for a measurement. A state value is an instance of a measurement from a specific source. Measurements can be associated with many state values, each representing a different source for the measurement.",
4936 attrs: &[
4937 AttrDef { id: "MeasurementValue.MeasurementValueQuality", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "MeasurementValueQuality", is_list: false, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "A MeasurementValue has a MeasurementValueQuality associated with it." },
4938 AttrDef { id: "MeasurementValue.MeasurementValueSource", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "MeasurementValueSource", is_list: false, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "A reference to the type of source that updates the MeasurementValue, e.g. SCADA, CCLink, manual, etc. User conventions for the names of sources are contained in the introduction to IEC 61970-301." },
4939 AttrDef { id: "MeasurementValue.sensorAccuracy", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PerCent", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["OP"], comment: "The limit, expressed as a percentage of the sensor maximum, that errors will not exceed when the sensor is used under reference conditions." },
4940 AttrDef { id: "MeasurementValue.timeStamp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "DateTime", is_list: false, used: true, xsd: "dateTime", value_ns: "", origins: &["OP"], comment: "The time when the value was last updated." },
4941 ],
4942 },
4943 ClassDef {
4944 ns: "http://iec.ch/TC57/CIM100#",
4945 local: "MeasurementValueQuality",
4946 qualified: "MeasurementValueQuality",
4947 super_class: Some(307),
4948 concrete: true,
4949 origins: &["OP"],
4950 comment: "Measurement quality flags. Bits 0-10 are defined for substation automation in IEC 61850-7-3. Bits 11-15 are reserved for future expansion by that document. Bits 16-31 are reserved for EMS applications.",
4951 attrs: &[
4952 AttrDef { id: "MeasurementValueQuality.MeasurementValue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "MeasurementValue", is_list: false, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "A MeasurementValue has a MeasurementValueQuality associated with it." },
4953 ],
4954 },
4955 ClassDef {
4956 ns: "http://iec.ch/TC57/CIM100#",
4957 local: "MeasurementValueSource",
4958 qualified: "MeasurementValueSource",
4959 super_class: Some(213),
4960 concrete: true,
4961 origins: &["OP"],
4962 comment: "MeasurementValueSource describes the alternative sources updating a MeasurementValue. User conventions for how to use the MeasurementValueSource attributes are defined in IEC 61970-301.",
4963 attrs: &[
4964 AttrDef { id: "MeasurementValueSource.MeasurementValues", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "MeasurementValue", is_list: true, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "The MeasurementValues updated by the source." },
4965 ],
4966 },
4967 ClassDef {
4968 ns: "http://iec.ch/TC57/CIM100#",
4969 local: "MechLoad1",
4970 qualified: "MechLoad1",
4971 super_class: Some(238),
4972 concrete: true,
4973 origins: &["DY"],
4974 comment: "Mechanical load model type 1.",
4975 attrs: &[
4976 AttrDef { id: "MechLoad1.a", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Speed squared coefficient (a)." },
4977 AttrDef { id: "MechLoad1.b", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Speed coefficient (b)." },
4978 AttrDef { id: "MechLoad1.d", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Speed to the exponent coefficient (d)." },
4979 AttrDef { id: "MechLoad1.e", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Exponent (e)." },
4980 ],
4981 },
4982 ClassDef {
4983 ns: "http://iec.ch/TC57/CIM100#",
4984 local: "MechanicalLoadDynamics",
4985 qualified: "MechanicalLoadDynamics",
4986 super_class: Some(91),
4987 concrete: false,
4988 origins: &["DY"],
4989 comment: "Mechanical load function block whose behaviour is described by reference to a standard model or by definition of a user-defined model.",
4990 attrs: &[
4991 AttrDef { id: "MechanicalLoadDynamics.AsynchronousMachineDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "AsynchronousMachineDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Asynchronous machine model with which this mechanical load model is associated. MechanicalLoadDynamics shall have either an association to SynchronousMachineDynamics or to AsynchronousMachineDynamics." },
4992 AttrDef { id: "MechanicalLoadDynamics.SynchronousMachineDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SynchronousMachineDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Synchronous machine model with which this mechanical load model is associated. MechanicalLoadDynamics shall have either an association to SynchronousMachineDynamics or AsynchronousMachineDyanmics." },
4993 ],
4994 },
4995 ClassDef {
4996 ns: "http://iec.ch/TC57/CIM100#",
4997 local: "MechanicalLoadUserDefined",
4998 qualified: "MechanicalLoadUserDefined",
4999 super_class: Some(238),
5000 concrete: true,
5001 origins: &["DY"],
5002 comment: "Mechanical load function block whose dynamic behaviour is described by a user-defined model.",
5003 attrs: &[
5004 AttrDef { id: "MechanicalLoadUserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
5005 AttrDef { id: "MechanicalLoadUserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
5006 ],
5007 },
5008 ClassDef {
5009 ns: "http://iec.ch/TC57/61970-552/ModelDescription/1#",
5010 local: "Model",
5011 qualified: "Model",
5012 super_class: None,
5013 concrete: false,
5014 origins: &["FH"],
5015 comment: "A Model is a collection of data describing instances, objects or entities, real or computed. In the context of CIM the semantics of the data is defined by profiles. Hence a model can contain equipment data, power flow initial values, power flow results etc. The Model class describes the header content that is the same for the FullModel and the DifferenceModel. A Model is identified by an rdf:about attribute. The rdf:about attribute uniquely describe the model data and not the CIMXML document. A new rdf:about identification is generated for created documents only when the model data has changed. A repeated creation of documents from unchanged model data shall have the same rdf:about identification as previous document generated from the same model data.",
5016 attrs: &[
5017 AttrDef { id: "Model.DependentOn", ns: "http://iec.ch/TC57/61970-552/ModelDescription/1#", kind: AttrKind::Association, range: "Model", is_list: true, used: true, xsd: "", value_ns: "", origins: &["FH"], comment: "A reference to the model documents that the model described by this document depends on. In general there can be 0 or many Model.DependentOn depending on the profile and the content of the instance file. For instance: - A load flow solution depends on the topology model it was computed from - A topology model computed by a topology processor depends on the network model it was computed from. The referenced models are identified by the FullModel rdf:about attribute for full model documents and by DifferenceModel rdf:about attribute for difference model documents. The references are maintained by the producer of the CIMXML document and the references are valid for the model with version and identifier for which the document was created." },
5018 AttrDef { id: "Model.Depending", ns: "http://iec.ch/TC57/61970-552/ModelDescription/1#", kind: AttrKind::Association, range: "Model", is_list: true, used: false, xsd: "", value_ns: "", origins: &["FH"], comment: "All documents depending on the model described by this document. This role is not intended to be included in any document exchanging instance data." },
5019 AttrDef { id: "Model.SupersededBy", ns: "http://iec.ch/TC57/61970-552/ModelDescription/1#", kind: AttrKind::Association, range: "Model", is_list: true, used: false, xsd: "", value_ns: "", origins: &["FH"], comment: "All models superseding this model. This role is not intended to be included in any document exchanging instance data." },
5020 AttrDef { id: "Model.Supersedes", ns: "http://iec.ch/TC57/61970-552/ModelDescription/1#", kind: AttrKind::Association, range: "Model", is_list: true, used: true, xsd: "", value_ns: "", origins: &["FH"], comment: "When a model is updated the resulting model supersedes the models that were used as basis for the update. Hence this is a reference to the CIMXML documents which are superseded by this model. A model (or instance file) can supersede 1 or more models, e.g. a difference model or a full model supersede multiple models (difference or full). In this case more than one Model.Supersedes are included in the header. The referenced document(s) is (are) identified by the URN/MRID/UUID in the FullModel rdf:about attribute when full model(s) is (are) referenced and by the URN/MRID/UUID in the DifferenceModel rdf:about attribute when difference model(s) is (are) referenced." },
5021 AttrDef { id: "Model.created", ns: "http://iec.ch/TC57/61970-552/ModelDescription/1#", kind: AttrKind::Literal, range: "DateTime", is_list: false, used: true, xsd: "dateTime", value_ns: "", origins: &["FH"], comment: "The date and time when the model was created. It is the time of the serialization. The format is an extended format according to the ISO 8601-2005. European exchanges shall refer to UTC, e.g. 2014-05-15T17:48:31.474Z." },
5022 AttrDef { id: "Model.description", ns: "http://iec.ch/TC57/61970-552/ModelDescription/1#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["FH"], comment: "A description of the model, e.g. the name of person that created the model and for what purpose. The number of UTF-8 characters is limited to 2000." },
5023 AttrDef { id: "Model.modelingAuthoritySet", ns: "http://iec.ch/TC57/61970-552/ModelDescription/1#", kind: AttrKind::Literal, range: "URI", is_list: false, used: true, xsd: "anyURI", value_ns: "", origins: &["FH"], comment: "A URN/URI referring to the organisation role / model authority set reference. The organization role is the source of the model. It is the same for all profiles part of a model exchange." },
5024 AttrDef { id: "Model.profile", ns: "http://iec.ch/TC57/61970-552/ModelDescription/1#", kind: AttrKind::Literal, range: "URI", is_list: true, used: true, xsd: "anyURI", value_ns: "", origins: &["FH"], comment: "URN/URI describing the profiles that governs this model. It uniquely identifies the profiles and its version, e.g. http://iec.ch/TC57/61970-456/SteadyStateHypothesis/2/0." },
5025 AttrDef { id: "Model.scenarioTime", ns: "http://iec.ch/TC57/61970-552/ModelDescription/1#", kind: AttrKind::Literal, range: "DateTime", is_list: false, used: true, xsd: "dateTime", value_ns: "", origins: &["FH"], comment: "The date and time that this model represents, i.e. for which the model is valid. The format is an extended format according to the ISO 8601-2005. European exchanges shall refer to UTC, e.g. 2030-01-15T17:00:00.000Z." },
5026 AttrDef { id: "Model.version", ns: "http://iec.ch/TC57/61970-552/ModelDescription/1#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["FH"], comment: "The version of the model. If the instance file is imported and exported with no change the version number is the kept same. The version changes only if the content of the file changes. It is the same logic as for the header id. The version is the human readable id." },
5027 ],
5028 },
5029 ClassDef {
5030 ns: "http://iec.ch/TC57/CIM100#",
5031 local: "MutualCoupling",
5032 qualified: "MutualCoupling",
5033 super_class: Some(213),
5034 concrete: true,
5035 origins: &["SC"],
5036 comment: "This class represents the zero sequence line mutual coupling.",
5037 attrs: &[
5038 AttrDef { id: "MutualCoupling.First_Terminal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Terminal", is_list: false, used: true, xsd: "", value_ns: "", origins: &["SC"], comment: "The starting terminal for the calculation of distances along the first branch of the mutual coupling. Normally MutualCoupling would only be used for terminals of AC line segments. The first and second terminals of a mutual coupling should point to different AC line segments." },
5039 AttrDef { id: "MutualCoupling.Second_Terminal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Terminal", is_list: false, used: true, xsd: "", value_ns: "", origins: &["SC"], comment: "The starting terminal for the calculation of distances along the second branch of the mutual coupling." },
5040 AttrDef { id: "MutualCoupling.b0ch", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Susceptance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence mutual coupling shunt (charging) susceptance, uniformly distributed, of the entire line section." },
5041 AttrDef { id: "MutualCoupling.distance11", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Length", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Distance to the start of the coupled region from the first line's terminal having sequence number equal to 1." },
5042 AttrDef { id: "MutualCoupling.distance12", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Length", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Distance to the end of the coupled region from the first line's terminal with sequence number equal to 1." },
5043 AttrDef { id: "MutualCoupling.distance21", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Length", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Distance to the start of coupled region from the second line's terminal with sequence number equal to 1." },
5044 AttrDef { id: "MutualCoupling.distance22", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Length", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Distance to the end of coupled region from the second line's terminal with sequence number equal to 1." },
5045 AttrDef { id: "MutualCoupling.g0ch", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Conductance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence mutual coupling shunt (charging) conductance, uniformly distributed, of the entire line section." },
5046 AttrDef { id: "MutualCoupling.r0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence branch-to-branch mutual impedance coupling, resistance." },
5047 AttrDef { id: "MutualCoupling.x0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence branch-to-branch mutual impedance coupling, reactance." },
5048 ],
5049 },
5050 ClassDef {
5051 ns: "http://iec.ch/TC57/CIM100#",
5052 local: "NonConformLoad",
5053 qualified: "NonConformLoad",
5054 super_class: Some(95),
5055 concrete: true,
5056 origins: &["EQ", "SSH"],
5057 comment: "NonConformLoad represents loads that do not follow a daily load change pattern and whose changes are not correlated with the daily load change pattern.",
5058 attrs: &[
5059 AttrDef { id: "NonConformLoad.LoadGroup", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "NonConformLoadGroup", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "Group of this ConformLoad." },
5060 ],
5061 },
5062 ClassDef {
5063 ns: "http://iec.ch/TC57/CIM100#",
5064 local: "NonConformLoadGroup",
5065 qualified: "NonConformLoadGroup",
5066 super_class: Some(227),
5067 concrete: true,
5068 origins: &["EQ"],
5069 comment: "Loads that do not follow a daily and seasonal load variation pattern.",
5070 attrs: &[
5071 AttrDef { id: "NonConformLoadGroup.EnergyConsumers", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "NonConformLoad", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "Conform loads assigned to this ConformLoadGroup." },
5072 AttrDef { id: "NonConformLoadGroup.NonConformLoadSchedules", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "NonConformLoadSchedule", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The NonConformLoadSchedules in the NonConformLoadGroup." },
5073 ],
5074 },
5075 ClassDef {
5076 ns: "http://iec.ch/TC57/CIM100#",
5077 local: "NonConformLoadSchedule",
5078 qualified: "NonConformLoadSchedule",
5079 super_class: Some(325),
5080 concrete: true,
5081 origins: &["EQ"],
5082 comment: "An active power (Y1-axis) and reactive power (Y2-axis) schedule (curves) versus time (X-axis) for non-conforming loads, e.g., large industrial load or power station service (where modelled).",
5083 attrs: &[
5084 AttrDef { id: "NonConformLoadSchedule.NonConformLoadGroup", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "NonConformLoadGroup", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The NonConformLoadGroup where the NonConformLoadSchedule belongs." },
5085 ],
5086 },
5087 ClassDef {
5088 ns: "http://iec.ch/TC57/CIM100#",
5089 local: "NonlinearShuntCompensator",
5090 qualified: "NonlinearShuntCompensator",
5091 super_class: Some(330),
5092 concrete: true,
5093 origins: &["EQ", "SSH"],
5094 comment: "A non linear shunt compensator has bank or section admittance values that differ. The attributes g, b, g0 and b0 of the associated NonlinearShuntCompensatorPoint describe the total conductance and admittance of a NonlinearShuntCompensatorPoint at a section number specified by NonlinearShuntCompensatorPoint.sectionNumber.",
5095 attrs: &[
5096 AttrDef { id: "NonlinearShuntCompensator.NonlinearShuntCompensatorPoints", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "NonlinearShuntCompensatorPoint", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "All points of the non-linear shunt compensator." },
5097 ],
5098 },
5099 ClassDef {
5100 ns: "http://iec.ch/TC57/CIM100#",
5101 local: "NonlinearShuntCompensatorPoint",
5102 qualified: "NonlinearShuntCompensatorPoint",
5103 super_class: None,
5104 concrete: true,
5105 origins: &["EQ", "SC"],
5106 comment: "A non linear shunt compensator bank or section admittance value. The number of NonlinearShuntCompenstorPoint instances associated with a NonlinearShuntCompensator shall be equal to ShuntCompensator.maximumSections. ShuntCompensator.sections shall only be set to one of the NonlinearShuntCompenstorPoint.sectionNumber. There is no interpolation between NonlinearShuntCompenstorPoint-s.",
5107 attrs: &[
5108 AttrDef { id: "NonlinearShuntCompensatorPoint.NonlinearShuntCompensator", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "NonlinearShuntCompensator", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "Non-linear shunt compensator owning this point." },
5109 AttrDef { id: "NonlinearShuntCompensatorPoint.b", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Susceptance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Positive sequence shunt (charging) susceptance per section." },
5110 AttrDef { id: "NonlinearShuntCompensatorPoint.b0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Susceptance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence shunt (charging) susceptance per section." },
5111 AttrDef { id: "NonlinearShuntCompensatorPoint.g", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Conductance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Positive sequence shunt (charging) conductance per section." },
5112 AttrDef { id: "NonlinearShuntCompensatorPoint.g0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Conductance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence shunt (charging) conductance per section." },
5113 AttrDef { id: "NonlinearShuntCompensatorPoint.sectionNumber", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["EQ"], comment: "The number of the section." },
5114 ],
5115 },
5116 ClassDef {
5117 ns: "http://iec.ch/TC57/CIM100#",
5118 local: "NuclearGeneratingUnit",
5119 qualified: "NuclearGeneratingUnit",
5120 super_class: Some(169),
5121 concrete: true,
5122 origins: &["EQ", "SSH"],
5123 comment: "A nuclear generating unit.",
5124 attrs: &[],
5125 },
5126 ClassDef {
5127 ns: "http://iec.ch/TC57/CIM100#",
5128 local: "OperationalLimit",
5129 qualified: "OperationalLimit",
5130 super_class: Some(213),
5131 concrete: false,
5132 origins: &["EQ", "SSH"],
5133 comment: "A value and normal value associated with a specific kind of limit. The sub class value and normalValue attributes vary inversely to the associated OperationalLimitType.acceptableDuration (acceptableDuration for short). If a particular piece of equipment has multiple operational limits of the same kind (apparent power, current, etc.), the limit with the greatest acceptableDuration shall have the smallest limit value and the limit with the smallest acceptableDuration shall have the largest limit value. Note: A large current can only be allowed to flow through a piece of equipment for a short duration without causing damage, but a lesser current can be allowed to flow for a longer duration.",
5134 attrs: &[
5135 AttrDef { id: "OperationalLimit.OperationalLimitSet", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "OperationalLimitSet", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The limit set to which the limit values belong." },
5136 AttrDef { id: "OperationalLimit.OperationalLimitType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "OperationalLimitType", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The limit type associated with this limit." },
5137 ],
5138 },
5139 ClassDef {
5140 ns: "http://iec.ch/TC57/CIM100#",
5141 local: "OperationalLimitSet",
5142 qualified: "OperationalLimitSet",
5143 super_class: Some(213),
5144 concrete: true,
5145 origins: &["EQ"],
5146 comment: "A set of limits associated with equipment. Sets of limits might apply to a specific temperature, or season for example. A set of limits may contain different severities of limit levels that would apply to the same equipment. The set may contain limits of different types such as apparent power and current limits or high and low voltage limits that are logically applied together as a set.",
5147 attrs: &[
5148 AttrDef { id: "OperationalLimitSet.Equipment", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Equipment", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The equipment to which the limit set applies." },
5149 AttrDef { id: "OperationalLimitSet.OperationalLimitValue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "OperationalLimit", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "Values of equipment limits." },
5150 AttrDef { id: "OperationalLimitSet.Terminal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ACDCTerminal", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The terminal where the operational limit set apply." },
5151 ],
5152 },
5153 ClassDef {
5154 ns: "http://iec.ch/TC57/CIM100#",
5155 local: "OperationalLimitType",
5156 qualified: "OperationalLimitType",
5157 super_class: Some(213),
5158 concrete: true,
5159 origins: &["EQ"],
5160 comment: "The operational meaning of a category of limits.",
5161 attrs: &[
5162 AttrDef { id: "OperationalLimitType.OperationalLimit", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "OperationalLimit", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The operational limits associated with this type of limit." },
5163 AttrDef { id: "OperationalLimitType.acceptableDuration", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The nominal acceptable duration of the limit. Limits are commonly expressed in terms of the time limit for which the limit is normally acceptable. The actual acceptable duration of a specific limit may depend on other local factors such as temperature or wind speed. The attribute has meaning only if the flag isInfiniteDuration is set to false, hence it shall not be exchanged when isInfiniteDuration is set to true." },
5164 AttrDef { id: "OperationalLimitType.direction", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "OperationalLimitDirectionKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "The direction of the limit." },
5165 AttrDef { id: "OperationalLimitType.isInfiniteDuration", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["EQ"], comment: "Defines if the operational limit type has infinite duration. If true, the limit has infinite duration. If false, the limit has definite duration which is defined by the attribute acceptableDuration." },
5166 AttrDef { id: "OperationalLimitType.kind", ns: "http://iec.ch/TC57/CIM100-European#", kind: AttrKind::Association, range: "LimitKind", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "Types of limits defined in the ENTSO-E Operational Handbook Policy 3." },
5167 ],
5168 },
5169 ClassDef {
5170 ns: "http://iec.ch/TC57/CIM100#",
5171 local: "OverexcLim2",
5172 qualified: "OverexcLim2",
5173 super_class: Some(255),
5174 concrete: true,
5175 origins: &["DY"],
5176 comment: "Different from LimIEEEOEL, LimOEL2 has a fixed pickup threshold and reduces the excitation set-point by means of a non-windup integral regulator. Irated is the rated machine excitation current (calculated from nameplate conditions: Vnom, Pnom, CosPhinom).",
5177 attrs: &[
5178 AttrDef { id: "OverexcLim2.ifdlim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limit value of rated field current (IFDLIM). Typical value = 1,05." },
5179 AttrDef { id: "OverexcLim2.koi", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain Over excitation limiter (KOI). Typical value = 0,1." },
5180 AttrDef { id: "OverexcLim2.voimax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum error signal (VOIMAX) (> OverexcLim2.voimin). Typical value = 0." },
5181 AttrDef { id: "OverexcLim2.voimin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum error signal (VOIMIN) (< OverexcLim2.voimax). Typical value = -9999." },
5182 ],
5183 },
5184 ClassDef {
5185 ns: "http://iec.ch/TC57/CIM100#",
5186 local: "OverexcLimIEEE",
5187 qualified: "OverexcLimIEEE",
5188 super_class: Some(255),
5189 concrete: true,
5190 origins: &["DY"],
5191 comment: "The over excitation limiter model is intended to represent the significant features of OELs necessary for some large-scale system studies. It is the result of a pragmatic approach to obtain a model that can be widely applied with attainable data from generator owners. An attempt to include all variations in the functionality of OELs and duplicate how they interact with the rest of the excitation systems would likely result in a level of application insufficient for the studies for which they are intended. Reference: IEEE OEL 421.5-2005, 9.",
5192 attrs: &[
5193 AttrDef { id: "OverexcLimIEEE.hyst", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "OEL pickup/drop-out hysteresis (HYST). Typical value = 0,03." },
5194 AttrDef { id: "OverexcLimIEEE.ifdlim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "OEL timed field current limit (IFDLIM). Typical value = 1,05." },
5195 AttrDef { id: "OverexcLimIEEE.ifdmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "OEL instantaneous field current limit (IFDMAX). Typical value = 1,5." },
5196 AttrDef { id: "OverexcLimIEEE.itfpu", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "OEL timed field current limiter pickup level (ITFPU). Typical value = 1,05." },
5197 AttrDef { id: "OverexcLimIEEE.kcd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "OEL cooldown gain (KCD). Typical value = 1." },
5198 AttrDef { id: "OverexcLimIEEE.kramp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "OEL ramped limit rate (KRAMP). Unit = PU / s. Typical value = 10." },
5199 ],
5200 },
5201 ClassDef {
5202 ns: "http://iec.ch/TC57/CIM100#",
5203 local: "OverexcLimX1",
5204 qualified: "OverexcLimX1",
5205 super_class: Some(255),
5206 concrete: true,
5207 origins: &["DY"],
5208 comment: "Field voltage over excitation limiter.",
5209 attrs: &[
5210 AttrDef { id: "OverexcLimX1.efd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low voltage point on the inverse time characteristic (EFD1). Typical value = 1,1." },
5211 AttrDef { id: "OverexcLimX1.efd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Mid voltage point on the inverse time characteristic (EFD2). Typical value = 1,2." },
5212 AttrDef { id: "OverexcLimX1.efd3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High voltage point on the inverse time characteristic (EFD3). Typical value = 1,5." },
5213 AttrDef { id: "OverexcLimX1.efddes", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Desired field voltage (EFDDES). Typical value = 0,9." },
5214 AttrDef { id: "OverexcLimX1.efdrated", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rated field voltage (EFDRATED). Typical value = 1,05." },
5215 AttrDef { id: "OverexcLimX1.kmx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (KMX). Typical value = 0,01." },
5216 AttrDef { id: "OverexcLimX1.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time to trip the exciter at the low voltage point on the inverse time characteristic (TIME1) (>= 0). Typical value = 120." },
5217 AttrDef { id: "OverexcLimX1.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time to trip the exciter at the mid voltage point on the inverse time characteristic (TIME2) (>= 0). Typical value = 40." },
5218 AttrDef { id: "OverexcLimX1.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time to trip the exciter at the high voltage point on the inverse time characteristic (TIME3) (>= 0). Typical value = 15." },
5219 AttrDef { id: "OverexcLimX1.vlow", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low voltage limit (VLOW) (> 0)." },
5220 ],
5221 },
5222 ClassDef {
5223 ns: "http://iec.ch/TC57/CIM100#",
5224 local: "OverexcLimX2",
5225 qualified: "OverexcLimX2",
5226 super_class: Some(255),
5227 concrete: true,
5228 origins: &["DY"],
5229 comment: "Field voltage or current overexcitation limiter designed to protect the generator field of an AC machine with automatic excitation control from overheating due to prolonged overexcitation.",
5230 attrs: &[
5231 AttrDef { id: "OverexcLimX2.efd1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low voltage or current point on the inverse time characteristic (EFD1). Typical value = 1,1." },
5232 AttrDef { id: "OverexcLimX2.efd2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Mid voltage or current point on the inverse time characteristic (EFD2). Typical value = 1,2." },
5233 AttrDef { id: "OverexcLimX2.efd3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High voltage or current point on the inverse time characteristic (EFD3). Typical value = 1,5." },
5234 AttrDef { id: "OverexcLimX2.efddes", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Desired field voltage if m = false or desired field current if m = true (EFDDES). Typical value = 1." },
5235 AttrDef { id: "OverexcLimX2.efdrated", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rated field voltage if m = false or rated field current if m = true (EFDRATED). Typical value = 1,05." },
5236 AttrDef { id: "OverexcLimX2.kmx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (KMX). Typical value = 0,002." },
5237 AttrDef { id: "OverexcLimX2.m", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "(m). true = IFD limiting false = EFD limiting." },
5238 AttrDef { id: "OverexcLimX2.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time to trip the exciter at the low voltage or current point on the inverse time characteristic (TIME1) (>= 0). Typical value = 120." },
5239 AttrDef { id: "OverexcLimX2.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time to trip the exciter at the mid voltage or current point on the inverse time characteristic (TIME2) (>= 0). Typical value = 40." },
5240 AttrDef { id: "OverexcLimX2.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time to trip the exciter at the high voltage or current point on the inverse time characteristic (TIME3) (>= 0). Typical value = 15." },
5241 AttrDef { id: "OverexcLimX2.vlow", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low voltage limit (VLOW) (> 0)." },
5242 ],
5243 },
5244 ClassDef {
5245 ns: "http://iec.ch/TC57/CIM100#",
5246 local: "OverexcitationLimiterDynamics",
5247 qualified: "OverexcitationLimiterDynamics",
5248 super_class: Some(91),
5249 concrete: false,
5250 origins: &["DY"],
5251 comment: "Overexcitation limiter function block whose behaviour is described by reference to a standard model or by definition of a user-defined model.",
5252 attrs: &[
5253 AttrDef { id: "OverexcitationLimiterDynamics.ExcitationSystemDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ExcitationSystemDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Excitation system model with which this overexcitation limiter model is associated." },
5254 ],
5255 },
5256 ClassDef {
5257 ns: "http://iec.ch/TC57/CIM100#",
5258 local: "OverexcitationLimiterUserDefined",
5259 qualified: "OverexcitationLimiterUserDefined",
5260 super_class: Some(255),
5261 concrete: true,
5262 origins: &["DY"],
5263 comment: "Overexcitation limiter system function block whose dynamic behaviour is described by a user-defined model.",
5264 attrs: &[
5265 AttrDef { id: "OverexcitationLimiterUserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
5266 AttrDef { id: "OverexcitationLimiterUserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
5267 ],
5268 },
5269 ClassDef {
5270 ns: "http://iec.ch/TC57/CIM100#",
5271 local: "PFVArControllerType1Dynamics",
5272 qualified: "PFVArControllerType1Dynamics",
5273 super_class: Some(91),
5274 concrete: false,
5275 origins: &["DY"],
5276 comment: "Power factor or VAr controller type 1 function block whose behaviour is described by reference to a standard model or by definition of a user-defined model.",
5277 attrs: &[
5278 AttrDef { id: "PFVArControllerType1Dynamics.ExcitationSystemDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ExcitationSystemDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Excitation system model with which this power actor or VAr controller type 1 model is associated." },
5279 AttrDef { id: "PFVArControllerType1Dynamics.RemoteInputSignal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RemoteInputSignal", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Remote input signal used by this power factor or VAr controller type 1 model." },
5280 AttrDef { id: "PFVArControllerType1Dynamics.VoltageAdjusterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "VoltageAdjusterDynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Voltage adjuster model associated with this power factor or VAr controller type 1 model." },
5281 ],
5282 },
5283 ClassDef {
5284 ns: "http://iec.ch/TC57/CIM100#",
5285 local: "PFVArControllerType1UserDefined",
5286 qualified: "PFVArControllerType1UserDefined",
5287 super_class: Some(257),
5288 concrete: true,
5289 origins: &["DY"],
5290 comment: "Power factor or VAr controller type 1 function block whose dynamic behaviour is described by a user-defined model.",
5291 attrs: &[
5292 AttrDef { id: "PFVArControllerType1UserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
5293 AttrDef { id: "PFVArControllerType1UserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
5294 ],
5295 },
5296 ClassDef {
5297 ns: "http://iec.ch/TC57/CIM100#",
5298 local: "PFVArControllerType2Dynamics",
5299 qualified: "PFVArControllerType2Dynamics",
5300 super_class: Some(91),
5301 concrete: false,
5302 origins: &["DY"],
5303 comment: "Power factor or VAr controller type 2 function block whose behaviour is described by reference to a standard model or by definition of a user-defined model.",
5304 attrs: &[
5305 AttrDef { id: "PFVArControllerType2Dynamics.ExcitationSystemDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ExcitationSystemDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Excitation system model with which this power factor or VAr controller type 2 is associated." },
5306 ],
5307 },
5308 ClassDef {
5309 ns: "http://iec.ch/TC57/CIM100#",
5310 local: "PFVArControllerType2UserDefined",
5311 qualified: "PFVArControllerType2UserDefined",
5312 super_class: Some(259),
5313 concrete: true,
5314 origins: &["DY"],
5315 comment: "Power factor or VAr controller type 2 function block whose dynamic behaviour is described by a user-defined model.",
5316 attrs: &[
5317 AttrDef { id: "PFVArControllerType2UserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
5318 AttrDef { id: "PFVArControllerType2UserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
5319 ],
5320 },
5321 ClassDef {
5322 ns: "http://iec.ch/TC57/CIM100#",
5323 local: "PFVArType1IEEEPFController",
5324 qualified: "PFVArType1IEEEPFController",
5325 super_class: Some(257),
5326 concrete: true,
5327 origins: &["DY"],
5328 comment: "IEEE PF controller type 1 which operates by moving the voltage reference directly. Reference: IEEE 421.5-2005, 11.2.",
5329 attrs: &[
5330 AttrDef { id: "PFVArType1IEEEPFController.ovex", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Overexcitation Flag (OVEX) true = overexcited false = underexcited." },
5331 AttrDef { id: "PFVArType1IEEEPFController.tpfc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PF controller time delay (TPFC) (>= 0). Typical value = 5." },
5332 AttrDef { id: "PFVArType1IEEEPFController.vitmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum machine terminal current needed to enable pf/var controller (VITMIN)." },
5333 AttrDef { id: "PFVArType1IEEEPFController.vpf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Synchronous machine power factor (VPF)." },
5334 AttrDef { id: "PFVArType1IEEEPFController.vpfcbw", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PF controller deadband (VPFC_BW). Typical value = 0,05." },
5335 AttrDef { id: "PFVArType1IEEEPFController.vpfref", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PF controller reference (VPFREF)." },
5336 AttrDef { id: "PFVArType1IEEEPFController.vvtmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum machine terminal voltage needed for pf/var controller to be enabled (VVTMAX) (> PFVArType1IEEEPFController.vvtmin)." },
5337 AttrDef { id: "PFVArType1IEEEPFController.vvtmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum machine terminal voltage needed to enable pf/var controller (VVTMIN) (< PFVArType1IEEEPFController.vvtmax)." },
5338 ],
5339 },
5340 ClassDef {
5341 ns: "http://iec.ch/TC57/CIM100#",
5342 local: "PFVArType1IEEEVArController",
5343 qualified: "PFVArType1IEEEVArController",
5344 super_class: Some(257),
5345 concrete: true,
5346 origins: &["DY"],
5347 comment: "IEEE VAR controller type 1 which operates by moving the voltage reference directly. Reference: IEEE 421.5-2005, 11.3.",
5348 attrs: &[
5349 AttrDef { id: "PFVArType1IEEEVArController.tvarc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Var controller time delay (TVARC) (>= 0). Typical value = 5." },
5350 AttrDef { id: "PFVArType1IEEEVArController.vvar", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Synchronous machine power factor (VVAR)." },
5351 AttrDef { id: "PFVArType1IEEEVArController.vvarcbw", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Var controller deadband (VVARC_BW). Typical value = 0,02." },
5352 AttrDef { id: "PFVArType1IEEEVArController.vvarref", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Var controller reference (VVARREF)." },
5353 AttrDef { id: "PFVArType1IEEEVArController.vvtmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum machine terminal voltage needed for pf/VAr controller to be enabled (VVTMAX) (> PVFArType1IEEEVArController.vvtmin)." },
5354 AttrDef { id: "PFVArType1IEEEVArController.vvtmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum machine terminal voltage needed to enable pf/var controller (VVTMIN) (< PVFArType1IEEEVArController.vvtmax)." },
5355 ],
5356 },
5357 ClassDef {
5358 ns: "http://iec.ch/TC57/CIM100#",
5359 local: "PFVArType2Common1",
5360 qualified: "PFVArType2Common1",
5361 super_class: Some(259),
5362 concrete: true,
5363 origins: &["DY"],
5364 comment: "Power factor / reactive power regulator. This model represents the power factor or reactive power controller such as the Basler SCP-250. The controller measures power factor or reactive power (PU on generator rated power) and compares it with the operator's set point. [Footnote: Basler SCP-250 is an example of a suitable product available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of this product.]",
5365 attrs: &[
5366 AttrDef { id: "PFVArType2Common1.j", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Selector (J). true = control mode for reactive power false = control mode for power factor." },
5367 AttrDef { id: "PFVArType2Common1.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reset gain (Ki)." },
5368 AttrDef { id: "PFVArType2Common1.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Proportional gain (Kp)." },
5369 AttrDef { id: "PFVArType2Common1.max", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Output limit (max)." },
5370 AttrDef { id: "PFVArType2Common1.ref", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reference value of reactive power or power factor (Ref). The reference value is initialised by this model. This initialisation can override the value exchanged by this attribute to represent a plant operator's change of the reference setting." },
5371 ],
5372 },
5373 ClassDef {
5374 ns: "http://iec.ch/TC57/CIM100#",
5375 local: "PFVArType2IEEEPFController",
5376 qualified: "PFVArType2IEEEPFController",
5377 super_class: Some(259),
5378 concrete: true,
5379 origins: &["DY"],
5380 comment: "IEEE PF controller type 2 which is a summing point type controller making up the outside loop of a two-loop system. This controller is implemented as a slow PI type controller. The voltage regulator forms the inner loop and is implemented as a fast controller. Reference: IEEE 421.5-2005, 11.4.",
5381 attrs: &[
5382 AttrDef { id: "PFVArType2IEEEPFController.exlon", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Overexcitation or under excitation flag (EXLON) true = 1 (not in the overexcitation or underexcitation state, integral action is active) false = 0 (in the overexcitation or underexcitation state, so integral action is disabled to allow the limiter to play its role)." },
5383 AttrDef { id: "PFVArType2IEEEPFController.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Integral gain of the pf controller (KI). Typical value = 1." },
5384 AttrDef { id: "PFVArType2IEEEPFController.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Proportional gain of the pf controller (KP). Typical value = 1." },
5385 AttrDef { id: "PFVArType2IEEEPFController.pfref", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power factor reference (PFREF)." },
5386 AttrDef { id: "PFVArType2IEEEPFController.vclmt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum output of the pf controller (VCLMT). Typical value = 0,1." },
5387 AttrDef { id: "PFVArType2IEEEPFController.vref", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator reference (VREF)." },
5388 AttrDef { id: "PFVArType2IEEEPFController.vs", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Generator sensing voltage (VS)." },
5389 ],
5390 },
5391 ClassDef {
5392 ns: "http://iec.ch/TC57/CIM100#",
5393 local: "PFVArType2IEEEVArController",
5394 qualified: "PFVArType2IEEEVArController",
5395 super_class: Some(259),
5396 concrete: true,
5397 origins: &["DY"],
5398 comment: "IEEE VAR controller type 2 which is a summing point type controller. It makes up the outside loop of a two-loop system. This controller is implemented as a slow PI type controller, and the voltage regulator forms the inner loop and is implemented as a fast controller. Reference: IEEE 421.5-2005, 11.5.",
5399 attrs: &[
5400 AttrDef { id: "PFVArType2IEEEVArController.exlon", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Overexcitation or under excitation flag (EXLON) true = 1 (not in the overexcitation or underexcitation state, integral action is active) false = 0 (in the overexcitation or underexcitation state, so integral action is disabled to allow the limiter to play its role)." },
5401 AttrDef { id: "PFVArType2IEEEVArController.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Integral gain of the pf controller (KI)." },
5402 AttrDef { id: "PFVArType2IEEEVArController.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Proportional gain of the pf controller (KP)." },
5403 AttrDef { id: "PFVArType2IEEEVArController.qref", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive power reference (QREF)." },
5404 AttrDef { id: "PFVArType2IEEEVArController.vclmt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum output of the pf controller (VCLMT)." },
5405 AttrDef { id: "PFVArType2IEEEVArController.vref", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage regulator reference (VREF)." },
5406 AttrDef { id: "PFVArType2IEEEVArController.vs", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Generator sensing voltage (VS)." },
5407 ],
5408 },
5409 ClassDef {
5410 ns: "http://iec.ch/TC57/CIM100#",
5411 local: "PetersenCoil",
5412 qualified: "PetersenCoil",
5413 super_class: Some(92),
5414 concrete: true,
5415 origins: &["EQ", "SC"],
5416 comment: "A variable impedance device normally used to offset line charging during single line faults in an ungrounded section of network.",
5417 attrs: &[
5418 AttrDef { id: "PetersenCoil.mode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "PetersenCoilModeKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["SC"], comment: "The mode of operation of the Petersen coil." },
5419 AttrDef { id: "PetersenCoil.nominalU", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "The nominal voltage for which the coil is designed." },
5420 AttrDef { id: "PetersenCoil.offsetCurrent", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "CurrentFlow", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "The offset current that the Petersen coil controller is operating from the resonant point. This is normally a fixed amount for which the controller is configured and could be positive or negative. Typically 0 to 60 A depending on voltage and resonance conditions." },
5421 AttrDef { id: "PetersenCoil.positionCurrent", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "CurrentFlow", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "The control current used to control the Petersen coil also known as the position current. Typically in the range of 20 mA to 200 mA." },
5422 AttrDef { id: "PetersenCoil.xGroundMax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "The maximum reactance." },
5423 AttrDef { id: "PetersenCoil.xGroundMin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "The minimum reactance." },
5424 AttrDef { id: "PetersenCoil.xGroundNominal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "The nominal reactance. This is the operating point (normally over compensation) that is defined based on the resonance point in the healthy network condition. The impedance is calculated based on nominal voltage divided by position current." },
5425 ],
5426 },
5427 ClassDef {
5428 ns: "http://iec.ch/TC57/CIM100#",
5429 local: "PhaseTapChanger",
5430 qualified: "PhaseTapChanger",
5431 super_class: Some(362),
5432 concrete: false,
5433 origins: &["EQ", "SSH"],
5434 comment: "A transformer phase shifting tap model that controls the phase angle difference across the power transformer and potentially the active power flow through the power transformer. This phase tap model may also impact the voltage magnitude.",
5435 attrs: &[
5436 AttrDef { id: "PhaseTapChanger.TransformerEnd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TransformerEnd", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "Transformer end to which this phase tap changer belongs." },
5437 ],
5438 },
5439 ClassDef {
5440 ns: "http://iec.ch/TC57/CIM100#",
5441 local: "PhaseTapChangerAsymmetrical",
5442 qualified: "PhaseTapChangerAsymmetrical",
5443 super_class: Some(270),
5444 concrete: true,
5445 origins: &["EQ", "SSH"],
5446 comment: "Describes the tap model for an asymmetrical phase shifting transformer in which the difference voltage vector adds to the in-phase winding. The out-of-phase winding is the transformer end where the tap changer is located. The angle between the in-phase and out-of-phase windings is named the winding connection angle. The phase shift depends on both the difference voltage magnitude and the winding connection angle.",
5447 attrs: &[
5448 AttrDef { id: "PhaseTapChangerAsymmetrical.windingConnectionAngle", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The phase angle between the in-phase winding and the out-of -phase winding used for creating phase shift. The out-of-phase winding produces what is known as the difference voltage. Setting this angle to 90 degrees is not the same as a symmetrical transformer. The attribute can only be multiples of 30 degrees. The allowed range is -150 degrees to 150 degrees excluding 0." },
5449 ],
5450 },
5451 ClassDef {
5452 ns: "http://iec.ch/TC57/CIM100#",
5453 local: "PhaseTapChangerLinear",
5454 qualified: "PhaseTapChangerLinear",
5455 super_class: Some(267),
5456 concrete: true,
5457 origins: &["EQ", "SSH"],
5458 comment: "Describes a tap changer with a linear relation between the tap step and the phase angle difference across the transformer. This is a mathematical model that is an approximation of a real phase tap changer. The phase angle is computed as stepPhaseShiftIncrement times the tap position. The voltage magnitude of both sides is the same.",
5459 attrs: &[
5460 AttrDef { id: "PhaseTapChangerLinear.stepPhaseShiftIncrement", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Phase shift per step position. A positive value indicates a positive angle variation from the Terminal at the PowerTransformerEnd, where the TapChanger is located, into the transformer. The actual phase shift increment might be more accurately computed from the symmetrical or asymmetrical models or a tap step table lookup if those are available." },
5461 AttrDef { id: "PhaseTapChangerLinear.xMax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The reactance depends on the tap position according to a 'u' shaped curve. The maximum reactance (xMax) appears at the low and high tap positions. Depending on the “u” curve the attribute can be either higher or lower than PowerTransformerEnd.x." },
5462 AttrDef { id: "PhaseTapChangerLinear.xMin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The reactance depends on the tap position according to a 'u' shaped curve. The minimum reactance (xMin) appears at the mid tap position. PowerTransformerEnd.x shall be consistent with PhaseTapChangerLinear.xMin and PhaseTapChangerNonLinear.xMin. In case of inconsistency, PowerTransformerEnd.x shall be used." },
5463 ],
5464 },
5465 ClassDef {
5466 ns: "http://iec.ch/TC57/CIM100#",
5467 local: "PhaseTapChangerNonLinear",
5468 qualified: "PhaseTapChangerNonLinear",
5469 super_class: Some(267),
5470 concrete: false,
5471 origins: &["EQ", "SSH"],
5472 comment: "The non-linear phase tap changer describes the non-linear behaviour of a phase tap changer. This is a base class for the symmetrical and asymmetrical phase tap changer models. The details of these models can be found in IEC 61970-301.",
5473 attrs: &[
5474 AttrDef { id: "PhaseTapChangerNonLinear.voltageStepIncrement", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PerCent", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The voltage step increment on the out of phase winding (the PowerTransformerEnd where the TapChanger is located) specified in percent of rated voltage of the PowerTransformerEnd. A positive value means a positive voltage variation from the Terminal at the PowerTransformerEnd, where the TapChanger is located, into the transformer. When the increment is negative, the voltage decreases when the tap step increases." },
5475 AttrDef { id: "PhaseTapChangerNonLinear.xMax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The reactance depends on the tap position according to a 'u' shaped curve. The maximum reactance (xMax) appears at the low and high tap positions. Depending on the “u” curve the attribute can be either higher or lower than PowerTransformerEnd.x." },
5476 AttrDef { id: "PhaseTapChangerNonLinear.xMin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The reactance depend on the tap position according to a 'u' shaped curve. The minimum reactance (xMin) appear at the mid tap position. PowerTransformerEnd.x shall be consistent with PhaseTapChangerLinear.xMin and PhaseTapChangerNonLinear.xMin. In case of inconsistency, PowerTransformerEnd.x shall be used." },
5477 ],
5478 },
5479 ClassDef {
5480 ns: "http://iec.ch/TC57/CIM100#",
5481 local: "PhaseTapChangerSymmetrical",
5482 qualified: "PhaseTapChangerSymmetrical",
5483 super_class: Some(270),
5484 concrete: true,
5485 origins: &["EQ", "SSH"],
5486 comment: "Describes a symmetrical phase shifting transformer tap model in which the voltage magnitude of both sides is the same. The difference voltage magnitude is the base in an equal-sided triangle where the sides corresponds to the primary and secondary voltages. The phase angle difference corresponds to the top angle and can be expressed as twice the arctangent of half the total difference voltage.",
5487 attrs: &[],
5488 },
5489 ClassDef {
5490 ns: "http://iec.ch/TC57/CIM100#",
5491 local: "PhaseTapChangerTable",
5492 qualified: "PhaseTapChangerTable",
5493 super_class: Some(213),
5494 concrete: true,
5495 origins: &["EQ"],
5496 comment: "Describes a tabular curve for how the phase angle difference and impedance varies with the tap step.",
5497 attrs: &[
5498 AttrDef { id: "PhaseTapChangerTable.PhaseTapChangerTablePoint", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PhaseTapChangerTablePoint", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The points of this table." },
5499 AttrDef { id: "PhaseTapChangerTable.PhaseTapChangerTabular", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PhaseTapChangerTabular", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The phase tap changers to which this phase tap table applies." },
5500 ],
5501 },
5502 ClassDef {
5503 ns: "http://iec.ch/TC57/CIM100#",
5504 local: "PhaseTapChangerTablePoint",
5505 qualified: "PhaseTapChangerTablePoint",
5506 super_class: Some(364),
5507 concrete: true,
5508 origins: &["EQ"],
5509 comment: "Describes each tap step in the phase tap changer tabular curve.",
5510 attrs: &[
5511 AttrDef { id: "PhaseTapChangerTablePoint.PhaseTapChangerTable", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PhaseTapChangerTable", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The table of this point." },
5512 AttrDef { id: "PhaseTapChangerTablePoint.angle", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The angle difference in degrees. A positive value indicates a positive angle variation from the Terminal at the PowerTransformerEnd, where the TapChanger is located, into the transformer." },
5513 ],
5514 },
5515 ClassDef {
5516 ns: "http://iec.ch/TC57/CIM100#",
5517 local: "PhaseTapChangerTabular",
5518 qualified: "PhaseTapChangerTabular",
5519 super_class: Some(267),
5520 concrete: true,
5521 origins: &["EQ", "SSH"],
5522 comment: "Describes a tap changer with a table defining the relation between the tap step and the phase angle difference across the transformer.",
5523 attrs: &[
5524 AttrDef { id: "PhaseTapChangerTabular.PhaseTapChangerTable", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PhaseTapChangerTable", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The phase tap changer table for this phase tap changer." },
5525 ],
5526 },
5527 ClassDef {
5528 ns: "http://iec.ch/TC57/CIM100#",
5529 local: "PhotoVoltaicUnit",
5530 qualified: "PhotoVoltaicUnit",
5531 super_class: Some(280),
5532 concrete: true,
5533 origins: &["EQ"],
5534 comment: "A photovoltaic device or an aggregation of such devices.",
5535 attrs: &[],
5536 },
5537 ClassDef {
5538 ns: "http://iec.ch/TC57/CIM100#",
5539 local: "PositionPoint",
5540 qualified: "PositionPoint",
5541 super_class: None,
5542 concrete: true,
5543 origins: &["GL"],
5544 comment: "Set of spatial coordinates that determine a point, defined in the coordinate system specified in 'Location.CoordinateSystem'. Use a single position point instance to describe a point-oriented location. Use a sequence of position points to describe a line-oriented object (physical location of non-point oriented objects like cables or lines), or area of an object (like a substation or a geographical zone - in this case, have first and last position point with the same values).",
5545 attrs: &[
5546 AttrDef { id: "PositionPoint.Location", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Location", is_list: false, used: true, xsd: "", value_ns: "", origins: &["GL"], comment: "Location described by this position point." },
5547 AttrDef { id: "PositionPoint.sequenceNumber", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["GL"], comment: "Zero-relative sequence number of this point within a series of points." },
5548 AttrDef { id: "PositionPoint.xPosition", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "X axis position." },
5549 AttrDef { id: "PositionPoint.yPosition", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "Y axis position." },
5550 AttrDef { id: "PositionPoint.zPosition", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "(if applicable) Z axis position." },
5551 ],
5552 },
5553 ClassDef {
5554 ns: "http://iec.ch/TC57/CIM100#",
5555 local: "PostLineSensor",
5556 qualified: "PostLineSensor",
5557 super_class: Some(326),
5558 concrete: true,
5559 origins: &["EQ"],
5560 comment: "A sensor used mainly in overhead distribution networks as the source of both current and voltage measurements.",
5561 attrs: &[],
5562 },
5563 ClassDef {
5564 ns: "http://iec.ch/TC57/CIM100#",
5565 local: "PotentialTransformer",
5566 qualified: "PotentialTransformer",
5567 super_class: Some(326),
5568 concrete: true,
5569 origins: &["EQ"],
5570 comment: "Instrument transformer (also known as Voltage Transformer) used to measure electrical qualities of the circuit that is being protected and/or monitored. Typically used as voltage transducer for the purpose of metering, protection, or sometimes auxiliary substation supply. A typical secondary voltage rating would be 120V.",
5571 attrs: &[],
5572 },
5573 ClassDef {
5574 ns: "http://iec.ch/TC57/CIM100#",
5575 local: "PowerElectronicsConnection",
5576 qualified: "PowerElectronicsConnection",
5577 super_class: Some(315),
5578 concrete: true,
5579 origins: &["EQ", "DY", "SSH"],
5580 comment: "A connection to the AC network for energy production or consumption that uses power electronics rather than rotating machines.",
5581 attrs: &[
5582 AttrDef { id: "PowerElectronicsConnection.PowerElectronicsUnit", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PowerElectronicsUnit", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "An AC network connection may have several power electronics units connecting through it." },
5583 AttrDef { id: "PowerElectronicsConnection.WindTurbineType3or4Dynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType3or4Dynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "The wind turbine type 3 or type 4 dynamics model associated with this power electronics connection." },
5584 AttrDef { id: "PowerElectronicsConnection.maxQ", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Maximum reactive power limit. This is the maximum (nameplate) limit for the unit." },
5585 AttrDef { id: "PowerElectronicsConnection.minQ", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Minimum reactive power limit for the unit. This is the minimum (nameplate) limit for the unit." },
5586 AttrDef { id: "PowerElectronicsConnection.p", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Active power injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for a steady state solution." },
5587 AttrDef { id: "PowerElectronicsConnection.q", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Reactive power injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for a steady state solution." },
5588 AttrDef { id: "PowerElectronicsConnection.ratedS", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ApparentPower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Nameplate apparent power rating for the unit. The attribute shall have a positive value." },
5589 AttrDef { id: "PowerElectronicsConnection.ratedU", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Rated voltage (nameplate data, Ur in IEC 60909-0). It is primarily used for short circuit data exchange according to IEC 60909. The attribute shall be a positive value." },
5590 ],
5591 },
5592 ClassDef {
5593 ns: "http://iec.ch/TC57/CIM100#",
5594 local: "PowerElectronicsUnit",
5595 qualified: "PowerElectronicsUnit",
5596 super_class: Some(98),
5597 concrete: false,
5598 origins: &["EQ", "SSH"],
5599 comment: "A generating unit or battery or aggregation that connects to the AC network using power electronics rather than rotating machines.",
5600 attrs: &[
5601 AttrDef { id: "PowerElectronicsUnit.PowerElectronicsConnection", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PowerElectronicsConnection", is_list: false, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "A power electronics unit has a connection to the AC network." },
5602 AttrDef { id: "PowerElectronicsUnit.maxP", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Maximum active power limit. This is the maximum (nameplate) limit for the unit." },
5603 AttrDef { id: "PowerElectronicsUnit.minP", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Minimum active power limit. This is the minimum (nameplate) limit for the unit." },
5604 ],
5605 },
5606 ClassDef {
5607 ns: "http://iec.ch/TC57/CIM100#",
5608 local: "PowerElectronicsWindUnit",
5609 qualified: "PowerElectronicsWindUnit",
5610 super_class: Some(280),
5611 concrete: true,
5612 origins: &["EQ"],
5613 comment: "A wind generating unit that connects to the AC network with power electronics rather than rotating machines or an aggregation of such units.",
5614 attrs: &[],
5615 },
5616 ClassDef {
5617 ns: "http://iec.ch/TC57/CIM100#",
5618 local: "PowerSystemResource",
5619 qualified: "PowerSystemResource",
5620 super_class: Some(213),
5621 concrete: false,
5622 origins: &["EQ", "DY", "EQBD", "GL", "OP", "SC", "SSH"],
5623 comment: "A power system resource (PSR) can be an item of equipment such as a switch, an equipment container containing many individual items of equipment such as a substation, or an organisational entity such as sub-control area. Power system resources can have measurements associated.",
5624 attrs: &[
5625 AttrDef { id: "PowerSystemResource.Controls", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Control", is_list: true, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "The controller outputs used to actually govern a regulating device, e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator." },
5626 AttrDef { id: "PowerSystemResource.Location", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Location", is_list: false, used: false, xsd: "", value_ns: "", origins: &["GL"], comment: "Location of this power system resource." },
5627 AttrDef { id: "PowerSystemResource.Measurements", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Measurement", is_list: true, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "The measurements associated with this power system resource." },
5628 ],
5629 },
5630 ClassDef {
5631 ns: "http://iec.ch/TC57/CIM100#",
5632 local: "PowerSystemStabilizerDynamics",
5633 qualified: "PowerSystemStabilizerDynamics",
5634 super_class: Some(91),
5635 concrete: false,
5636 origins: &["DY"],
5637 comment: "Power system stabilizer function block whose behaviour is described by reference to a standard model or by definition of a user-defined model.",
5638 attrs: &[
5639 AttrDef { id: "PowerSystemStabilizerDynamics.ExcitationSystemDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ExcitationSystemDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Excitation system model with which this power system stabilizer model is associated." },
5640 AttrDef { id: "PowerSystemStabilizerDynamics.RemoteInputSignal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RemoteInputSignal", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Remote input signal used by this power system stabilizer model." },
5641 ],
5642 },
5643 ClassDef {
5644 ns: "http://iec.ch/TC57/CIM100#",
5645 local: "PowerSystemStabilizerUserDefined",
5646 qualified: "PowerSystemStabilizerUserDefined",
5647 super_class: Some(283),
5648 concrete: true,
5649 origins: &["DY"],
5650 comment: "Power system stabilizer function block whose dynamic behaviour is described by a user-defined model.",
5651 attrs: &[
5652 AttrDef { id: "PowerSystemStabilizerUserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
5653 AttrDef { id: "PowerSystemStabilizerUserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
5654 ],
5655 },
5656 ClassDef {
5657 ns: "http://iec.ch/TC57/CIM100#",
5658 local: "PowerTransformer",
5659 qualified: "PowerTransformer",
5660 super_class: Some(37),
5661 concrete: true,
5662 origins: &["EQ", "SC"],
5663 comment: "An electrical device consisting of two or more coupled windings, with or without a magnetic core, for introducing mutual coupling between electric circuits. Transformers can be used to control voltage and phase shift (active power flow). A power transformer may be composed of separate transformer tanks that need not be identical. A power transformer can be modelled with or without tanks and is intended for use in both balanced and unbalanced representations. A power transformer typically has two terminals, but may have one (grounding), three or more terminals. The inherited association ConductingEquipment.BaseVoltage should not be used. The association from TransformerEnd to BaseVoltage should be used instead.",
5664 attrs: &[
5665 AttrDef { id: "PowerTransformer.PowerTransformerEnd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PowerTransformerEnd", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The ends of this power transformer." },
5666 AttrDef { id: "PowerTransformer.beforeShCircuitHighestOperatingCurrent", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "CurrentFlow", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "The highest operating current (Ib in IEC 60909-0) before short circuit (depends on network configuration and relevant reliability philosophy). It is used for calculation of the impedance correction factor KT defined in IEC 60909-0." },
5667 AttrDef { id: "PowerTransformer.beforeShCircuitHighestOperatingVoltage", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "The highest operating voltage (Ub in IEC 60909-0) before short circuit. It is used for calculation of the impedance correction factor KT defined in IEC 60909-0. This is worst case voltage on the low side winding (3.7.1 of IEC 60909:2001). Used to define operating conditions." },
5668 AttrDef { id: "PowerTransformer.beforeShortCircuitAnglePf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "The angle of power factor before short circuit (phib in IEC 60909-0). It is used for calculation of the impedance correction factor KT defined in IEC 60909-0. This is the worst case power factor. Used to define operating conditions." },
5669 AttrDef { id: "PowerTransformer.highSideMinOperatingU", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "The minimum operating voltage (uQmin in IEC 60909-0) at the high voltage side (Q side) of the unit transformer of the power station unit. A value well established from long-term operating experience of the system. It is used for calculation of the impedance correction factor KG defined in IEC 60909-0." },
5670 AttrDef { id: "PowerTransformer.isPartOfGeneratorUnit", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["SC"], comment: "Indicates whether the machine is part of a power station unit. Used for short circuit data exchange according to IEC 60909. It has an impact on how the correction factors are calculated for transformers, since the transformer is not necessarily part of a synchronous machine and generating unit. It is not always possible to derive this information from the model. This is why the attribute is necessary." },
5671 AttrDef { id: "PowerTransformer.operationalValuesConsidered", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["SC"], comment: "It is used to define if the data (other attributes related to short circuit data exchange) defines long term operational conditions or not. Used for short circuit data exchange according to IEC 60909." },
5672 ],
5673 },
5674 ClassDef {
5675 ns: "http://iec.ch/TC57/CIM100#",
5676 local: "PowerTransformerEnd",
5677 qualified: "PowerTransformerEnd",
5678 super_class: Some(373),
5679 concrete: true,
5680 origins: &["EQ", "SC"],
5681 comment: "A PowerTransformerEnd is associated with each Terminal of a PowerTransformer. The impedance values r, r0, x, and x0 of a PowerTransformerEnd represents a star equivalent as follows. 1) for a two Terminal PowerTransformer the high voltage (TransformerEnd.endNumber=1) PowerTransformerEnd has non zero values on r, r0, x, and x0 while the low voltage (TransformerEnd.endNumber=2) PowerTransformerEnd has zero values for r, r0, x, and x0. Parameters are always provided, even if the PowerTransformerEnds have the same rated voltage. In this case, the parameters are provided at the PowerTransformerEnd which has TransformerEnd.endNumber equal to 1. 2) for a three Terminal PowerTransformer the three PowerTransformerEnds represent a star equivalent with each leg in the star represented by r, r0, x, and x0 values. 3) For a three Terminal transformer each PowerTransformerEnd shall have g, g0, b and b0 values corresponding to the no load losses distributed on the three PowerTransformerEnds. The total no load loss shunt impedances may also be placed at one of the PowerTransformerEnds, preferably the end numbered 1, having the shunt values on end 1. This is the preferred way. 4) for a PowerTransformer with more than three Terminals the PowerTransformerEnd impedance values cannot be used. Instead use the TransformerMeshImpedance or split the transformer into multiple PowerTransformers. Each PowerTransformerEnd must be contained by a PowerTransformer. Because a PowerTransformerEnd (or any other object) can not be contained by more than one parent, a PowerTransformerEnd can not have an association to an EquipmentContainer (Substation, VoltageLevel, etc).",
5682 attrs: &[
5683 AttrDef { id: "PowerTransformerEnd.PowerTransformer", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PowerTransformer", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The power transformer of this power transformer end." },
5684 AttrDef { id: "PowerTransformerEnd.b", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Susceptance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Magnetizing branch susceptance (B mag). The value can be positive or negative." },
5685 AttrDef { id: "PowerTransformerEnd.b0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Susceptance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence magnetizing branch susceptance." },
5686 AttrDef { id: "PowerTransformerEnd.connectionKind", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "WindingConnection", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "Kind of connection." },
5687 AttrDef { id: "PowerTransformerEnd.g", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Conductance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Magnetizing branch conductance." },
5688 AttrDef { id: "PowerTransformerEnd.g0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Conductance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence magnetizing branch conductance (star-model)." },
5689 AttrDef { id: "PowerTransformerEnd.phaseAngleClock", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["SC"], comment: "Terminal voltage phase angle displacement where 360 degrees are represented with clock hours. The valid values are 0 to 11. For example, for the secondary side end of a transformer with vector group code of 'Dyn11', specify the connection kind as wye with neutral and specify the phase angle of the clock as 11. The clock value of the transformer end number specified as 1, is assumed to be zero. Note the transformer end number is not assumed to be the same as the terminal sequence number." },
5690 AttrDef { id: "PowerTransformerEnd.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Resistance (star-model) of the transformer end. The attribute shall be equal to or greater than zero for non-equivalent transformers." },
5691 AttrDef { id: "PowerTransformerEnd.r0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence series resistance (star-model) of the transformer end." },
5692 AttrDef { id: "PowerTransformerEnd.ratedS", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ApparentPower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Normal apparent power rating. The attribute shall be a positive value. For a two-winding transformer the values for the high and low voltage sides shall be identical." },
5693 AttrDef { id: "PowerTransformerEnd.ratedU", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Rated voltage: phase-phase for three-phase windings, and either phase-phase or phase-neutral for single-phase windings. A high voltage side, as given by TransformerEnd.endNumber, shall have a ratedU that is greater than or equal to ratedU for the lower voltage sides. The attribute shall be a positive value." },
5694 AttrDef { id: "PowerTransformerEnd.x", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Positive sequence series reactance (star-model) of the transformer end." },
5695 AttrDef { id: "PowerTransformerEnd.x0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence series reactance of the transformer end." },
5696 ],
5697 },
5698 ClassDef {
5699 ns: "http://iec.ch/TC57/CIM100#",
5700 local: "ProprietaryParameterDynamics",
5701 qualified: "ProprietaryParameterDynamics",
5702 super_class: None,
5703 concrete: true,
5704 origins: &["DY"],
5705 comment: "Supports definition of one or more parameters of several different datatypes for use by proprietary user-defined models. This class does not inherit from IdentifiedObject since it is not intended that a single instance of it be referenced by more than one proprietary user-defined model instance.",
5706 attrs: &[
5707 AttrDef { id: "ProprietaryParameterDynamics.AsynchronousMachineUserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "AsynchronousMachineUserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5708 AttrDef { id: "ProprietaryParameterDynamics.CSCUserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "CSCUserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5709 AttrDef { id: "ProprietaryParameterDynamics.DiscontinuousExcitationControlUserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DiscontinuousExcitationControlUserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5710 AttrDef { id: "ProprietaryParameterDynamics.ExcitationSystemUserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ExcitationSystemUserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5711 AttrDef { id: "ProprietaryParameterDynamics.LoadUserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "LoadUserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5712 AttrDef { id: "ProprietaryParameterDynamics.MechanicalLoadUserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "MechanicalLoadUserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5713 AttrDef { id: "ProprietaryParameterDynamics.OverexcitationLimiterUserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "OverexcitationLimiterUserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5714 AttrDef { id: "ProprietaryParameterDynamics.PFVArControllerType1UserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PFVArControllerType1UserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5715 AttrDef { id: "ProprietaryParameterDynamics.PFVArControllerType2UserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PFVArControllerType2UserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5716 AttrDef { id: "ProprietaryParameterDynamics.PowerSystemStabilizerUserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PowerSystemStabilizerUserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5717 AttrDef { id: "ProprietaryParameterDynamics.SVCUserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SVCUserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5718 AttrDef { id: "ProprietaryParameterDynamics.SynchronousMachineUserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SynchronousMachineUserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5719 AttrDef { id: "ProprietaryParameterDynamics.TurbineGovernorUserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TurbineGovernorUserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5720 AttrDef { id: "ProprietaryParameterDynamics.TurbineLoadControllerUserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TurbineLoadControllerUserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5721 AttrDef { id: "ProprietaryParameterDynamics.UnderexcitationLimiterUserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "UnderexcitationLimiterUserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5722 AttrDef { id: "ProprietaryParameterDynamics.VSCUserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "VSCUserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5723 AttrDef { id: "ProprietaryParameterDynamics.VoltageAdjusterUserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "VoltageAdjusterUserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5724 AttrDef { id: "ProprietaryParameterDynamics.VoltageCompensatorUserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "VoltageCompensatorUserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5725 AttrDef { id: "ProprietaryParameterDynamics.WindPlantUserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindPlantUserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5726 AttrDef { id: "ProprietaryParameterDynamics.WindType1or2UserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindType1or2UserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5727 AttrDef { id: "ProprietaryParameterDynamics.WindType3or4UserDefined", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindType3or4UserDefined", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Proprietary user-defined model with which this parameter is associated." },
5728 AttrDef { id: "ProprietaryParameterDynamics.booleanParameterValue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Boolean parameter value. If this attribute is populated, integerParameterValue and floatParameterValue will not be." },
5729 AttrDef { id: "ProprietaryParameterDynamics.floatParameterValue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Floating point parameter value. If this attribute is populated, booleanParameterValue and integerParameterValue will not be." },
5730 AttrDef { id: "ProprietaryParameterDynamics.integerParameterValue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["DY"], comment: "Integer parameter value. If this attribute is populated, booleanParameterValue and floatParameterValue will not be." },
5731 AttrDef { id: "ProprietaryParameterDynamics.parameterNumber", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["DY"], comment: "Sequence number of the parameter among the set of parameters associated with the related proprietary user-defined model." },
5732 ],
5733 },
5734 ClassDef {
5735 ns: "http://iec.ch/TC57/CIM100#",
5736 local: "ProtectedSwitch",
5737 qualified: "ProtectedSwitch",
5738 super_class: Some(353),
5739 concrete: false,
5740 origins: &["EQ", "SSH"],
5741 comment: "A ProtectedSwitch is a switching device that can be operated by ProtectionEquipment.",
5742 attrs: &[],
5743 },
5744 ClassDef {
5745 ns: "http://iec.ch/TC57/CIM100#",
5746 local: "Pss1",
5747 qualified: "Pss1",
5748 super_class: Some(283),
5749 concrete: true,
5750 origins: &["DY"],
5751 comment: "Italian PSS with three inputs (speed, frequency, power).",
5752 attrs: &[
5753 AttrDef { id: "Pss1.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency power input gain (KF). Typical value = 5." },
5754 AttrDef { id: "Pss1.komega", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Shaft speed power input gain (Komega). Typical value = 0." },
5755 AttrDef { id: "Pss1.kpe", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Electric power input gain (KPE). Typical value = 0,3." },
5756 AttrDef { id: "Pss1.ks", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PSS gain (Ks). Typical value = 1." },
5757 AttrDef { id: "Pss1.pmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum power PSS enabling (Pmin). Typical value = 0,25." },
5758 AttrDef { id: "Pss1.t10", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T10) (>= 0). Typical value = 0." },
5759 AttrDef { id: "Pss1.t5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Washout (T5) (>= 0). Typical value = 3,5." },
5760 AttrDef { id: "Pss1.t6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter time constant (T6) (>= 0). Typical value = 0." },
5761 AttrDef { id: "Pss1.t7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T7) (>= 0). If = 0, both blocks are bypassed. Typical value = 0." },
5762 AttrDef { id: "Pss1.t8", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T8) (>= 0). Typical value = 0." },
5763 AttrDef { id: "Pss1.t9", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T9) (>= 0). If = 0, both blocks are bypassed. Typical value = 0." },
5764 AttrDef { id: "Pss1.tpe", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Electric power filter time constant (TPE) (>= 0). Typical value = 0,05." },
5765 AttrDef { id: "Pss1.vadat", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Signal selector (VADAT). true = closed (generator power is greater than Pmin) false = open (Pe is smaller than Pmin). Typical value = true." },
5766 AttrDef { id: "Pss1.vsmn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer output maximum limit (VSMN). Typical value = -0,06." },
5767 AttrDef { id: "Pss1.vsmx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer output minimum limit (VSMX). Typical value = 0,06." },
5768 ],
5769 },
5770 ClassDef {
5771 ns: "http://iec.ch/TC57/CIM100#",
5772 local: "Pss1A",
5773 qualified: "Pss1A",
5774 super_class: Some(283),
5775 concrete: true,
5776 origins: &["DY"],
5777 comment: "Single input power system stabilizer. It is a modified version in order to allow representation of various vendors' implementations on PSS type 1A.",
5778 attrs: &[
5779 AttrDef { id: "Pss1A.a1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter parameter (A1)." },
5780 AttrDef { id: "Pss1A.a2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter parameter (A2)." },
5781 AttrDef { id: "Pss1A.a3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter parameter (A3)." },
5782 AttrDef { id: "Pss1A.a4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter parameter (A4)." },
5783 AttrDef { id: "Pss1A.a5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter parameter (A5)." },
5784 AttrDef { id: "Pss1A.a6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter parameter (A6)." },
5785 AttrDef { id: "Pss1A.a7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter parameter (A7)." },
5786 AttrDef { id: "Pss1A.a8", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter parameter (A8)." },
5787 AttrDef { id: "Pss1A.inputSignalType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "InputSignalKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Type of input signal (rotorAngularFrequencyDeviation, busFrequencyDeviation, generatorElectricalPower, generatorAcceleratingPower, busVoltage, or busVoltageDerivative)." },
5788 AttrDef { id: "Pss1A.kd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Selector (Kd). true = e-sTdelay used false = e-sTdelay not used." },
5789 AttrDef { id: "Pss1A.ks", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer gain (Ks)." },
5790 AttrDef { id: "Pss1A.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T1) (>= 0)." },
5791 AttrDef { id: "Pss1A.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T2) (>= 0)." },
5792 AttrDef { id: "Pss1A.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T3) (>= 0)." },
5793 AttrDef { id: "Pss1A.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T4) (>= 0)." },
5794 AttrDef { id: "Pss1A.t5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Washout time constant (T5) (>= 0)." },
5795 AttrDef { id: "Pss1A.t6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Transducer time constant (T6) (>= 0)." },
5796 AttrDef { id: "Pss1A.tdelay", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Tdelay) (>= 0)." },
5797 AttrDef { id: "Pss1A.vcl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer input cutoff threshold (Vcl)." },
5798 AttrDef { id: "Pss1A.vcu", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer input cutoff threshold (Vcu)." },
5799 AttrDef { id: "Pss1A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum stabilizer output (Vrmax) (> Pss1A.vrmin)." },
5800 AttrDef { id: "Pss1A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum stabilizer output (Vrmin) (< Pss1A.vrmax)." },
5801 ],
5802 },
5803 ClassDef {
5804 ns: "http://iec.ch/TC57/CIM100#",
5805 local: "Pss2B",
5806 qualified: "Pss2B",
5807 super_class: Some(283),
5808 concrete: true,
5809 origins: &["DY"],
5810 comment: "Modified IEEE PSS2B. Extra lead/lag (or rate) block added at end (up to 4 lead/lags total).",
5811 attrs: &[
5812 AttrDef { id: "Pss2B.a", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Numerator constant (a). Typical value = 1." },
5813 AttrDef { id: "Pss2B.ks1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer gain (Ks1). Typical value = 12." },
5814 AttrDef { id: "Pss2B.ks2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain on signal #2 (Ks2). Typical value = 0,2." },
5815 AttrDef { id: "Pss2B.ks3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain on signal #2 input before ramp-tracking filter (Ks3). Typical value = 1." },
5816 AttrDef { id: "Pss2B.ks4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain on signal #2 input after ramp-tracking filter (Ks4). Typical value = 1." },
5817 AttrDef { id: "Pss2B.m", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["DY"], comment: "Denominator order of ramp tracking filter (m). Typical value = 5." },
5818 AttrDef { id: "Pss2B.n", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["DY"], comment: "Order of ramp tracking filter (n). Typical value = 1." },
5819 AttrDef { id: "Pss2B.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T1) (>= 0). Typical value = 0,12." },
5820 AttrDef { id: "Pss2B.t10", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T10) (>= 0). Typical value = 0." },
5821 AttrDef { id: "Pss2B.t11", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T11) (>= 0). Typical value = 0." },
5822 AttrDef { id: "Pss2B.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T2) (>= 0). Typical value = 0,02." },
5823 AttrDef { id: "Pss2B.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T3) (>= 0). Typical value = 0,3." },
5824 AttrDef { id: "Pss2B.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T4) (>= 0). Typical value = 0,02." },
5825 AttrDef { id: "Pss2B.t6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant on signal #1 (T6) (>= 0). Typical value = 0." },
5826 AttrDef { id: "Pss2B.t7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant on signal #2 (T7) (>= 0). Typical value = 2." },
5827 AttrDef { id: "Pss2B.t8", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead of ramp tracking filter (T8) (>= 0). Typical value = 0,2." },
5828 AttrDef { id: "Pss2B.t9", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag of ramp tracking filter (T9) (>= 0). Typical value = 0,1." },
5829 AttrDef { id: "Pss2B.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead constant (Ta) (>= 0). Typical value = 0." },
5830 AttrDef { id: "Pss2B.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant (Tb) (>= 0). Typical value = 0." },
5831 AttrDef { id: "Pss2B.tw1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "First washout on signal #1 (Tw1) (>= 0). Typical value = 2." },
5832 AttrDef { id: "Pss2B.tw2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Second washout on signal #1 (Tw2) (>= 0). Typical value = 2." },
5833 AttrDef { id: "Pss2B.tw3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "First washout on signal #2 (Tw3) (>= 0). Typical value = 2." },
5834 AttrDef { id: "Pss2B.tw4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Second washout on signal #2 (Tw4) (>= 0). Typical value = 0." },
5835 AttrDef { id: "Pss2B.vsi1max", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input signal #1 maximum limit (Vsi1max) (> Pss2B.vsi1min). Typical value = 2." },
5836 AttrDef { id: "Pss2B.vsi1min", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input signal #1 minimum limit (Vsi1min) (< Pss2B.vsi1max). Typical value = -2." },
5837 AttrDef { id: "Pss2B.vsi2max", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input signal #2 maximum limit (Vsi2max) (> Pss2B.vsi2min). Typical value = 2." },
5838 AttrDef { id: "Pss2B.vsi2min", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input signal #2 minimum limit (Vsi2min) (< Pss2B.vsi2max). Typical value = -2." },
5839 AttrDef { id: "Pss2B.vstmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer output maximum limit (Vstmax) (> Pss2B.vstmin). Typical value = 0,1." },
5840 AttrDef { id: "Pss2B.vstmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer output minimum limit (Vstmin) (< Pss2B.vstmax). Typical value = -0,1." },
5841 ],
5842 },
5843 ClassDef {
5844 ns: "http://iec.ch/TC57/CIM100#",
5845 local: "Pss2ST",
5846 qualified: "Pss2ST",
5847 super_class: Some(283),
5848 concrete: true,
5849 origins: &["DY"],
5850 comment: "PTI microprocessor-based stabilizer type 1.",
5851 attrs: &[
5852 AttrDef { id: "Pss2ST.inputSignal1Type", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "InputSignalKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Type of input signal #1 (rotorAngularFrequencyDeviation, busFrequencyDeviation, generatorElectricalPower, generatorAcceleratingPower, busVoltage, or busVoltageDerivative - shall be different than Pss2ST.inputSignal2Type). Typical value = rotorAngularFrequencyDeviation." },
5853 AttrDef { id: "Pss2ST.inputSignal2Type", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "InputSignalKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Type of input signal #2 (rotorAngularFrequencyDeviation, busFrequencyDeviation, generatorElectricalPower, generatorAcceleratingPower, busVoltage, or busVoltageDerivative - shall be different than Pss2ST.inputSignal1Type). Typical value = busVoltageDerivative." },
5854 AttrDef { id: "Pss2ST.k1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (K1)." },
5855 AttrDef { id: "Pss2ST.k2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (K2)." },
5856 AttrDef { id: "Pss2ST.lsmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter (LSMAX) (> Pss2ST.lsmin)." },
5857 AttrDef { id: "Pss2ST.lsmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter (LSMIN) (< Pss2ST.lsmax)." },
5858 AttrDef { id: "Pss2ST.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T1) (>= 0)." },
5859 AttrDef { id: "Pss2ST.t10", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T10) (>= 0)." },
5860 AttrDef { id: "Pss2ST.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T2) (>= 0)." },
5861 AttrDef { id: "Pss2ST.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T3) (>= 0)." },
5862 AttrDef { id: "Pss2ST.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T4) (>= 0)." },
5863 AttrDef { id: "Pss2ST.t5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T5) (>= 0)." },
5864 AttrDef { id: "Pss2ST.t6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T6) (>= 0)." },
5865 AttrDef { id: "Pss2ST.t7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T7) (>= 0)." },
5866 AttrDef { id: "Pss2ST.t8", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T8) (>= 0)." },
5867 AttrDef { id: "Pss2ST.t9", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T9) (>= 0)." },
5868 AttrDef { id: "Pss2ST.vcl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Cutoff limiter (VCL)." },
5869 AttrDef { id: "Pss2ST.vcu", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Cutoff limiter (VCU)." },
5870 ],
5871 },
5872 ClassDef {
5873 ns: "http://iec.ch/TC57/CIM100#",
5874 local: "Pss5",
5875 qualified: "Pss5",
5876 super_class: Some(283),
5877 concrete: true,
5878 origins: &["DY"],
5879 comment: "Detailed Italian PSS.",
5880 attrs: &[
5881 AttrDef { id: "Pss5.ctw2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Selector for second washout enabling (CTW2). true = second washout filter is bypassed false = second washout filter in use. Typical value = true." },
5882 AttrDef { id: "Pss5.deadband", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer output deadband (DEADBAND). Typical value = 0." },
5883 AttrDef { id: "Pss5.isfreq", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Selector for frequency/shaft speed input (isFreq). true = speed (same meaning as InputSignaKind.rotorSpeed) false = frequency (same meaning as InputSignalKind.busFrequency). Typical value = true (same meaning as InputSignalKind.rotorSpeed)." },
5884 AttrDef { id: "Pss5.kf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency/shaft speed input gain (KF). Typical value = 5." },
5885 AttrDef { id: "Pss5.kpe", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Electric power input gain (KPE). Typical value = 0,3." },
5886 AttrDef { id: "Pss5.kpss", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PSS gain (KPSS). Typical value = 1." },
5887 AttrDef { id: "Pss5.pmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum power PSS enabling (Pmin). Typical value = 0,25." },
5888 AttrDef { id: "Pss5.tl1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (TL1) (>= 0). Typical value = 0." },
5889 AttrDef { id: "Pss5.tl2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (TL2) (>= 0). If = 0, both blocks are bypassed. Typical value = 0." },
5890 AttrDef { id: "Pss5.tl3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (TL3) (>= 0). Typical value = 0." },
5891 AttrDef { id: "Pss5.tl4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (TL4) (>= 0). If = 0, both blocks are bypassed. Typical value = 0." },
5892 AttrDef { id: "Pss5.tpe", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Electric power filter time constant (TPE) (>= 0). Typical value = 0,05." },
5893 AttrDef { id: "Pss5.tw1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "First washout (TW1) (>= 0). Typical value = 3,5." },
5894 AttrDef { id: "Pss5.tw2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Second washout (TW2) (>= 0). Typical value = 0." },
5895 AttrDef { id: "Pss5.vadat", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Signal selector (VadAtt). true = closed (generator power is greater than Pmin) false = open (Pe is smaller than Pmin). Typical value = true." },
5896 AttrDef { id: "Pss5.vsmn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer output maximum limit (VSMN). Typical value = -0,1." },
5897 AttrDef { id: "Pss5.vsmx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer output minimum limit (VSMX). Typical value = 0,1." },
5898 ],
5899 },
5900 ClassDef {
5901 ns: "http://iec.ch/TC57/CIM100#",
5902 local: "PssELIN2",
5903 qualified: "PssELIN2",
5904 super_class: Some(283),
5905 concrete: true,
5906 origins: &["DY"],
5907 comment: "Power system stabilizer typically associated with ExcELIN2 (though PssIEEE2B or Pss2B can also be used).",
5908 attrs: &[
5909 AttrDef { id: "PssELIN2.apss", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient (a_PSS). Typical value = 0,1." },
5910 AttrDef { id: "PssELIN2.ks1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (Ks1). Typical value = 1." },
5911 AttrDef { id: "PssELIN2.ks2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (Ks2). Typical value = 0,1." },
5912 AttrDef { id: "PssELIN2.ppss", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient (p_PSS) (>= 0 and <= 4). Typical value = 0,1." },
5913 AttrDef { id: "PssELIN2.psslim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PSS limiter (psslim). Typical value = 0,1." },
5914 AttrDef { id: "PssELIN2.ts1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Ts1) (>= 0). Typical value = 0." },
5915 AttrDef { id: "PssELIN2.ts2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Ts2) (>= 0). Typical value = 1." },
5916 AttrDef { id: "PssELIN2.ts3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Ts3) (>= 0). Typical value = 1." },
5917 AttrDef { id: "PssELIN2.ts4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Ts4) (>= 0). Typical value = 0,1." },
5918 AttrDef { id: "PssELIN2.ts5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Ts5) (>= 0). Typical value = 0." },
5919 AttrDef { id: "PssELIN2.ts6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Ts6) (>= 0). Typical value = 1." },
5920 ],
5921 },
5922 ClassDef {
5923 ns: "http://iec.ch/TC57/CIM100#",
5924 local: "PssIEEE1A",
5925 qualified: "PssIEEE1A",
5926 super_class: Some(283),
5927 concrete: true,
5928 origins: &["DY"],
5929 comment: "IEEE 421.5-2005 type PSS1A power system stabilizer model. PSS1A is the generalized form of a PSS with a single input signal. Reference: IEEE 1A 421.5-2005, 8.1.",
5930 attrs: &[
5931 AttrDef { id: "PssIEEE1A.a1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PSS signal conditioning frequency filter constant (A1). Typical value = 0,061." },
5932 AttrDef { id: "PssIEEE1A.a2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PSS signal conditioning frequency filter constant (A2). Typical value = 0,0017." },
5933 AttrDef { id: "PssIEEE1A.inputSignalType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "InputSignalKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Type of input signal (rotorAngularFrequencyDeviation, generatorElectricalPower, or busFrequencyDeviation). Typical value = rotorAngularFrequencyDeviation." },
5934 AttrDef { id: "PssIEEE1A.ks", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer gain (Ks). Typical value = 5." },
5935 AttrDef { id: "PssIEEE1A.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T1) (>= 0). Typical value = 0,3." },
5936 AttrDef { id: "PssIEEE1A.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T2) (>= 0). Typical value = 0,03." },
5937 AttrDef { id: "PssIEEE1A.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T3) (>= 0). Typical value = 0,3." },
5938 AttrDef { id: "PssIEEE1A.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T4) (>= 0). Typical value = 0,03." },
5939 AttrDef { id: "PssIEEE1A.t5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Washout time constant (T5) (>= 0). Typical value = 10." },
5940 AttrDef { id: "PssIEEE1A.t6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Transducer time constant (T6) (>= 0). Typical value = 0,01." },
5941 AttrDef { id: "PssIEEE1A.vrmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum stabilizer output (Vrmax) (> PssIEEE1A.vrmin). Typical value = 0,05." },
5942 AttrDef { id: "PssIEEE1A.vrmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum stabilizer output (Vrmin) (< PssIEEE1A.vrmax). Typical value = -0,05." },
5943 ],
5944 },
5945 ClassDef {
5946 ns: "http://iec.ch/TC57/CIM100#",
5947 local: "PssIEEE2B",
5948 qualified: "PssIEEE2B",
5949 super_class: Some(283),
5950 concrete: true,
5951 origins: &["DY"],
5952 comment: "IEEE 421.5-2005 type PSS2B power system stabilizer model. This stabilizer model is designed to represent a variety of dual-input stabilizers, which normally use combinations of power and speed or frequency to derive the stabilizing signal. Reference: IEEE 2B 421.5-2005, 8.2.",
5953 attrs: &[
5954 AttrDef { id: "PssIEEE2B.inputSignal1Type", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "InputSignalKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Type of input signal #1 (rotorAngularFrequencyDeviation, busFrequencyDeviation). Typical value = rotorAngularFrequencyDeviation." },
5955 AttrDef { id: "PssIEEE2B.inputSignal2Type", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "InputSignalKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Type of input signal #2 (generatorElectricalPower). Typical value = generatorElectricalPower." },
5956 AttrDef { id: "PssIEEE2B.ks1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer gain (Ks1). Typical value = 12." },
5957 AttrDef { id: "PssIEEE2B.ks2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain on signal #2 (Ks2). Typical value = 0,2." },
5958 AttrDef { id: "PssIEEE2B.ks3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain on signal #2 input before ramp-tracking filter (Ks3). Typical value = 1." },
5959 AttrDef { id: "PssIEEE2B.m", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["DY"], comment: "Denominator order of ramp tracking filter (M). Typical value = 5." },
5960 AttrDef { id: "PssIEEE2B.n", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["DY"], comment: "Order of ramp tracking filter (N). Typical value = 1." },
5961 AttrDef { id: "PssIEEE2B.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T1) (>= 0). Typical value = 0,12." },
5962 AttrDef { id: "PssIEEE2B.t10", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T10) (>= 0). Typical value = 0." },
5963 AttrDef { id: "PssIEEE2B.t11", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T11) (>= 0). Typical value = 0." },
5964 AttrDef { id: "PssIEEE2B.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T2) (>= 0). Typical value = 0,02." },
5965 AttrDef { id: "PssIEEE2B.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T3) (>= 0). Typical value = 0,3." },
5966 AttrDef { id: "PssIEEE2B.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead/lag time constant (T4) (>= 0). Typical value = 0,02." },
5967 AttrDef { id: "PssIEEE2B.t6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant on signal #1 (T6) (>= 0). Typical value = 0." },
5968 AttrDef { id: "PssIEEE2B.t7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant on signal #2 (T7) (>= 0). Typical value = 2." },
5969 AttrDef { id: "PssIEEE2B.t8", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead of ramp tracking filter (T8) (>= 0). Typical value = 0,2." },
5970 AttrDef { id: "PssIEEE2B.t9", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag of ramp tracking filter (T9) (>= 0). Typical value = 0,1." },
5971 AttrDef { id: "PssIEEE2B.tw1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "First washout on signal #1 (Tw1) (>= 0). Typical value = 2." },
5972 AttrDef { id: "PssIEEE2B.tw2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Second washout on signal #1 (Tw2) (>= 0). Typical value = 2." },
5973 AttrDef { id: "PssIEEE2B.tw3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "First washout on signal #2 (Tw3) (>= 0). Typical value = 2." },
5974 AttrDef { id: "PssIEEE2B.tw4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Second washout on signal #2 (Tw4) (>= 0). Typical value = 0." },
5975 AttrDef { id: "PssIEEE2B.vsi1max", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input signal #1 maximum limit (Vsi1max) (> PssIEEE2B.vsi1min). Typical value = 2." },
5976 AttrDef { id: "PssIEEE2B.vsi1min", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input signal #1 minimum limit (Vsi1min) (< PssIEEE2B.vsi1max). Typical value = -2." },
5977 AttrDef { id: "PssIEEE2B.vsi2max", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input signal #2 maximum limit (Vsi2max) (> PssIEEE2B.vsi2min). Typical value = 2." },
5978 AttrDef { id: "PssIEEE2B.vsi2min", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input signal #2 minimum limit (Vsi2min) (< PssIEEE2B.vsi2max). Typical value = -2." },
5979 AttrDef { id: "PssIEEE2B.vstmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer output maximum limit (Vstmax) (> PssIEEE2B.vstmin). Typical value = 0,1." },
5980 AttrDef { id: "PssIEEE2B.vstmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer output minimum limit (Vstmin) (< PssIEEE2B.vstmax). Typical value = -0,1." },
5981 ],
5982 },
5983 ClassDef {
5984 ns: "http://iec.ch/TC57/CIM100#",
5985 local: "PssIEEE3B",
5986 qualified: "PssIEEE3B",
5987 super_class: Some(283),
5988 concrete: true,
5989 origins: &["DY"],
5990 comment: "IEEE 421.5-2005 type PSS3B power system stabilizer model. The PSS model PSS3B has dual inputs of electrical power and rotor angular frequency deviation. The signals are used to derive an equivalent mechanical power signal. This model has 2 input signals. They have the following fixed types (expressed in terms of InputSignalKind values): the first one is of rotorAngleFrequencyDeviation type and the second one is of generatorElectricalPower type. Reference: IEEE 3B 421.5-2005, 8.3.",
5991 attrs: &[
5992 AttrDef { id: "PssIEEE3B.a1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter parameter (A1). Typical value = 0,359." },
5993 AttrDef { id: "PssIEEE3B.a2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter parameter (A2). Typical value = 0,586." },
5994 AttrDef { id: "PssIEEE3B.a3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter parameter (A3). Typical value = 0,429." },
5995 AttrDef { id: "PssIEEE3B.a4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter parameter (A4). Typical value = 0,564." },
5996 AttrDef { id: "PssIEEE3B.a5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter parameter (A5). Typical value = 0,001." },
5997 AttrDef { id: "PssIEEE3B.a6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter parameter (A6). Typical value = 0." },
5998 AttrDef { id: "PssIEEE3B.a7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter parameter (A7). Typical value = 0,031." },
5999 AttrDef { id: "PssIEEE3B.a8", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter parameter (A8). Typical value = 0." },
6000 AttrDef { id: "PssIEEE3B.ks1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain on signal # 1 (Ks1). Typical value = -0,602." },
6001 AttrDef { id: "PssIEEE3B.ks2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain on signal # 2 (Ks2). Typical value = 30,12." },
6002 AttrDef { id: "PssIEEE3B.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Transducer time constant (T1) (>= 0). Typical value = 0,012." },
6003 AttrDef { id: "PssIEEE3B.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Transducer time constant (T2) (>= 0). Typical value = 0,012." },
6004 AttrDef { id: "PssIEEE3B.tw1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Washout time constant (Tw1) (>= 0). Typical value = 0,3." },
6005 AttrDef { id: "PssIEEE3B.tw2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Washout time constant (Tw2) (>= 0). Typical value = 0,3." },
6006 AttrDef { id: "PssIEEE3B.tw3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Washout time constant (Tw3) (>= 0). Typical value = 0,6." },
6007 AttrDef { id: "PssIEEE3B.vstmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer output maximum limit (Vstmax) (> PssIEEE3B.vstmin). Typical value = 0,1." },
6008 AttrDef { id: "PssIEEE3B.vstmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer output minimum limit (Vstmin) (< PssIEEE3B.vstmax). Typical value = -0,1." },
6009 ],
6010 },
6011 ClassDef {
6012 ns: "http://iec.ch/TC57/CIM100#",
6013 local: "PssIEEE4B",
6014 qualified: "PssIEEE4B",
6015 super_class: Some(283),
6016 concrete: true,
6017 origins: &["DY"],
6018 comment: "IEEE 421.5-2005 type PSS4B power system stabilizer. The PSS4B model represents a structure based on multiple working frequency bands. Three separate bands, respectively dedicated to the low-, intermediate- and high-frequency modes of oscillations, are used in this delta omega (speed input) PSS. There is an error in the in IEEE 421.5-2005 PSS4B model: the Pe input should read -Pe. This implies that the input Pe needs to be multiplied by -1. Reference: IEEE 4B 421.5-2005, 8.4. Parameter details: This model has 2 input signals. They have the following fixed types (expressed in terms of InputSignalKind values): the first one is of rotorAngleFrequencyDeviation type and the second one is of generatorElectricalPower type.",
6019 attrs: &[
6020 AttrDef { id: "PssIEEE4B.bwh1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter 1 (high-frequency band): three dB bandwidth (Bwi)." },
6021 AttrDef { id: "PssIEEE4B.bwh2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter 2 (high-frequency band): three dB bandwidth (Bwi)." },
6022 AttrDef { id: "PssIEEE4B.bwl1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter 1 (low-frequency band): three dB bandwidth (Bwi)." },
6023 AttrDef { id: "PssIEEE4B.bwl2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter 2 (low-frequency band): three dB bandwidth (Bwi)." },
6024 AttrDef { id: "PssIEEE4B.kh", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High band gain (KH). Typical value = 120." },
6025 AttrDef { id: "PssIEEE4B.kh1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High band differential filter gain (KH1). Typical value = 66." },
6026 AttrDef { id: "PssIEEE4B.kh11", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High band first lead-lag blocks coefficient (KH11). Typical value = 1." },
6027 AttrDef { id: "PssIEEE4B.kh17", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High band first lead-lag blocks coefficient (KH17). Typical value = 1." },
6028 AttrDef { id: "PssIEEE4B.kh2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High band differential filter gain (KH2). Typical value = 66." },
6029 AttrDef { id: "PssIEEE4B.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate band gain (KI). Typical value = 30." },
6030 AttrDef { id: "PssIEEE4B.ki1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate band differential filter gain (KI1). Typical value = 66." },
6031 AttrDef { id: "PssIEEE4B.ki11", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate band first lead-lag blocks coefficient (KI11). Typical value = 1." },
6032 AttrDef { id: "PssIEEE4B.ki17", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate band first lead-lag blocks coefficient (KI17). Typical value = 1." },
6033 AttrDef { id: "PssIEEE4B.ki2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate band differential filter gain (KI2). Typical value = 66." },
6034 AttrDef { id: "PssIEEE4B.kl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low band gain (KL). Typical value = 7.5." },
6035 AttrDef { id: "PssIEEE4B.kl1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low band differential filter gain (KL1). Typical value = 66." },
6036 AttrDef { id: "PssIEEE4B.kl11", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low band first lead-lag blocks coefficient (KL11). Typical value = 1." },
6037 AttrDef { id: "PssIEEE4B.kl17", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low band first lead-lag blocks coefficient (KL17). Typical value = 1." },
6038 AttrDef { id: "PssIEEE4B.kl2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low band differential filter gain (KL2). Typical value = 66." },
6039 AttrDef { id: "PssIEEE4B.omeganh1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter 1 (high-frequency band): filter frequency (omegani)." },
6040 AttrDef { id: "PssIEEE4B.omeganh2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter 2 (high-frequency band): filter frequency (omegani)." },
6041 AttrDef { id: "PssIEEE4B.omeganl1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter 1 (low-frequency band): filter frequency (omegani)." },
6042 AttrDef { id: "PssIEEE4B.omeganl2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Notch filter 2 (low-frequency band): filter frequency (omegani)." },
6043 AttrDef { id: "PssIEEE4B.th1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High band time constant (TH1) (>= 0). Typical value = 0,01513." },
6044 AttrDef { id: "PssIEEE4B.th10", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High band time constant (TH10) (>= 0). Typical value = 0." },
6045 AttrDef { id: "PssIEEE4B.th11", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High band time constant (TH11) (>= 0). Typical value = 0." },
6046 AttrDef { id: "PssIEEE4B.th12", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High band time constant (TH12) (>= 0). Typical value = 0." },
6047 AttrDef { id: "PssIEEE4B.th2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High band time constant (TH2) (>= 0). Typical value = 0,01816." },
6048 AttrDef { id: "PssIEEE4B.th3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High band time constant (TH3) (>= 0). Typical value = 0." },
6049 AttrDef { id: "PssIEEE4B.th4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High band time constant (TH4) (>= 0). Typical value = 0." },
6050 AttrDef { id: "PssIEEE4B.th5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High band time constant (TH5) (>= 0). Typical value = 0." },
6051 AttrDef { id: "PssIEEE4B.th6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High band time constant (TH6) (>= 0). Typical value = 0." },
6052 AttrDef { id: "PssIEEE4B.th7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High band time constant (TH7) (>= 0). Typical value = 0,01816." },
6053 AttrDef { id: "PssIEEE4B.th8", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High band time constant (TH8) (>= 0). Typical value = 0,02179." },
6054 AttrDef { id: "PssIEEE4B.th9", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High band time constant (TH9) (>= 0). Typical value = 0." },
6055 AttrDef { id: "PssIEEE4B.ti1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate band time constant (TI1) (>= 0). Typical value = 0,173." },
6056 AttrDef { id: "PssIEEE4B.ti10", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate band time constant (TI10) (>= 0). Typical value = 0." },
6057 AttrDef { id: "PssIEEE4B.ti11", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate band time constant (TI11) (>= 0). Typical value = 0." },
6058 AttrDef { id: "PssIEEE4B.ti12", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate band time constant (TI12) (>= 0). Typical value = 0." },
6059 AttrDef { id: "PssIEEE4B.ti2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate band time constant (TI2) (>= 0). Typical value = 0,2075." },
6060 AttrDef { id: "PssIEEE4B.ti3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate band time constant (TI3) (>= 0). Typical value = 0." },
6061 AttrDef { id: "PssIEEE4B.ti4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate band time constant (TI4) (>= 0). Typical value = 0." },
6062 AttrDef { id: "PssIEEE4B.ti5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate band time constant (TI5) (>= 0). Typical value = 0." },
6063 AttrDef { id: "PssIEEE4B.ti6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate band time constant (TI6) (>= 0). Typical value = 0." },
6064 AttrDef { id: "PssIEEE4B.ti7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate band time constant (TI7) (>= 0). Typical value = 0,2075." },
6065 AttrDef { id: "PssIEEE4B.ti8", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate band time constant (TI8) (>= 0). Typical value = 0,2491." },
6066 AttrDef { id: "PssIEEE4B.ti9", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate band time constant (TI9) (>= 0). Typical value = 0." },
6067 AttrDef { id: "PssIEEE4B.tl1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low band time constant (TL1) (>= 0). Typical value = 1,73." },
6068 AttrDef { id: "PssIEEE4B.tl10", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low band time constant (TL10) (>= 0). Typical value = 0." },
6069 AttrDef { id: "PssIEEE4B.tl11", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low band time constant (TL11) (>= 0). Typical value = 0." },
6070 AttrDef { id: "PssIEEE4B.tl12", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low band time constant (TL12) (>= 0). Typical value = 0." },
6071 AttrDef { id: "PssIEEE4B.tl2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low band time constant (TL2) (>= 0). Typical value = 2,075." },
6072 AttrDef { id: "PssIEEE4B.tl3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low band time constant (TL3) (>= 0). Typical value = 0." },
6073 AttrDef { id: "PssIEEE4B.tl4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low band time constant (TL4) (>= 0). Typical value = 0." },
6074 AttrDef { id: "PssIEEE4B.tl5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low band time constant (TL5) (>= 0). Typical value = 0." },
6075 AttrDef { id: "PssIEEE4B.tl6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low band time constant (TL6) (>= 0). Typical value = 0." },
6076 AttrDef { id: "PssIEEE4B.tl7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low band time constant (TL7) (>= 0). Typical value = 2,075." },
6077 AttrDef { id: "PssIEEE4B.tl8", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low band time constant (TL8) (>= 0). Typical value = 2,491." },
6078 AttrDef { id: "PssIEEE4B.tl9", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low band time constant (TL9) (>= 0). Typical value = 0." },
6079 AttrDef { id: "PssIEEE4B.vhmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High band output maximum limit (VHmax) (> PssIEEE4B.vhmin). Typical value = 0,6." },
6080 AttrDef { id: "PssIEEE4B.vhmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "High band output minimum limit (VHmin) (< PssIEEE4V.vhmax). Typical value = -0,6." },
6081 AttrDef { id: "PssIEEE4B.vimax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate band output maximum limit (VImax) (> PssIEEE4B.vimin). Typical value = 0,6." },
6082 AttrDef { id: "PssIEEE4B.vimin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Intermediate band output minimum limit (VImin) (< PssIEEE4B.vimax). Typical value = -0,6." },
6083 AttrDef { id: "PssIEEE4B.vlmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low band output maximum limit (VLmax) (> PssIEEE4B.vlmin). Typical value = 0,075." },
6084 AttrDef { id: "PssIEEE4B.vlmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Low band output minimum limit (VLmin) (< PssIEEE4B.vlmax). Typical value = -0,075." },
6085 AttrDef { id: "PssIEEE4B.vstmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PSS output maximum limit (VSTmax) (> PssIEEE4B.vstmin). Typical value = 0,15." },
6086 AttrDef { id: "PssIEEE4B.vstmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PSS output minimum limit (VSTmin) (< PssIEEE4B.vstmax). Typical value = -0,15." },
6087 ],
6088 },
6089 ClassDef {
6090 ns: "http://iec.ch/TC57/CIM100#",
6091 local: "PssPTIST1",
6092 qualified: "PssPTIST1",
6093 super_class: Some(283),
6094 concrete: true,
6095 origins: &["DY"],
6096 comment: "PTI microprocessor-based stabilizer type 1.",
6097 attrs: &[
6098 AttrDef { id: "PssPTIST1.dtc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time step related to activation of controls (deltatc) (>= 0). Typical value = 0,025." },
6099 AttrDef { id: "PssPTIST1.dtf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time step frequency calculation (deltatf) (>= 0). Typical value = 0,025." },
6100 AttrDef { id: "PssPTIST1.dtp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time step active power calculation (deltatp) (>= 0). Typical value = 0,0125." },
6101 AttrDef { id: "PssPTIST1.k", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (K). Typical value = 9." },
6102 AttrDef { id: "PssPTIST1.m", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "(M). M = 2 x H. Typical value = 5." },
6103 AttrDef { id: "PssPTIST1.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T1) (>= 0). Typical value = 0,3." },
6104 AttrDef { id: "PssPTIST1.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T2) (>= 0). Typical value = 1." },
6105 AttrDef { id: "PssPTIST1.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T3) (>= 0). Typical value = 0,2." },
6106 AttrDef { id: "PssPTIST1.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T4) (>= 0). Typical value = 0,05." },
6107 AttrDef { id: "PssPTIST1.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Tf) (>= 0). Typical value = 0,2." },
6108 AttrDef { id: "PssPTIST1.tp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Tp) (>= 0). Typical value = 0,2." },
6109 ],
6110 },
6111 ClassDef {
6112 ns: "http://iec.ch/TC57/CIM100#",
6113 local: "PssPTIST3",
6114 qualified: "PssPTIST3",
6115 super_class: Some(283),
6116 concrete: true,
6117 origins: &["DY"],
6118 comment: "PTI microprocessor-based stabilizer type 3.",
6119 attrs: &[
6120 AttrDef { id: "PssPTIST3.a0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter coefficient (A0)." },
6121 AttrDef { id: "PssPTIST3.a1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter (Al)." },
6122 AttrDef { id: "PssPTIST3.a2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter coefficient (A2)." },
6123 AttrDef { id: "PssPTIST3.a3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter coefficient (A3)." },
6124 AttrDef { id: "PssPTIST3.a4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter coefficient (A4)." },
6125 AttrDef { id: "PssPTIST3.a5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter coefficient (A5)." },
6126 AttrDef { id: "PssPTIST3.al", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter (Al)." },
6127 AttrDef { id: "PssPTIST3.athres", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Threshold value above which output averaging will be bypassed (Athres). Typical value = 0,005." },
6128 AttrDef { id: "PssPTIST3.b0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter coefficient (B0)." },
6129 AttrDef { id: "PssPTIST3.b1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter coefficient (B1)." },
6130 AttrDef { id: "PssPTIST3.b2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter coefficient (B2)." },
6131 AttrDef { id: "PssPTIST3.b3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter coefficient (B3)." },
6132 AttrDef { id: "PssPTIST3.b4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter coefficient (B4)." },
6133 AttrDef { id: "PssPTIST3.b5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter coefficient (B5)." },
6134 AttrDef { id: "PssPTIST3.dl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter (Dl)." },
6135 AttrDef { id: "PssPTIST3.dtc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time step related to activation of controls (deltatc) (>= 0). Typical value = 0,025 (0,03 for 50 Hz)." },
6136 AttrDef { id: "PssPTIST3.dtf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time step frequency calculation (deltatf) (>= 0). Typical value = 0,025 (0,03 for 50 Hz)." },
6137 AttrDef { id: "PssPTIST3.dtp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time step active power calculation (deltatp) (>= 0). Typical value = 0,0125 (0,015 for 50 Hz)." },
6138 AttrDef { id: "PssPTIST3.isw", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Digital/analogue output switch (Isw). true = produce analogue output false = convert to digital output, using tap selection table." },
6139 AttrDef { id: "PssPTIST3.k", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (K). Typical value = 9." },
6140 AttrDef { id: "PssPTIST3.lthres", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Threshold value (Lthres)." },
6141 AttrDef { id: "PssPTIST3.m", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "(M). M = 2 x H. Typical value = 5." },
6142 AttrDef { id: "PssPTIST3.nav", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Number of control outputs to average (NAV) (1 <= NAV <= 16). Typical value = 4." },
6143 AttrDef { id: "PssPTIST3.ncl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Number of counts at limit to active limit function (NCL) (> 0)." },
6144 AttrDef { id: "PssPTIST3.ncr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Number of counts until reset after limit function is triggered (NCR)." },
6145 AttrDef { id: "PssPTIST3.pmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "(Pmin)." },
6146 AttrDef { id: "PssPTIST3.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T1) (>= 0). Typical value = 0,3." },
6147 AttrDef { id: "PssPTIST3.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T2) (>= 0). Typical value = 1." },
6148 AttrDef { id: "PssPTIST3.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T3) (>= 0). Typical value = 0,2." },
6149 AttrDef { id: "PssPTIST3.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T4) (>= 0). Typical value = 0,05." },
6150 AttrDef { id: "PssPTIST3.t5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T5) (>= 0)." },
6151 AttrDef { id: "PssPTIST3.t6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T6) (>= 0)." },
6152 AttrDef { id: "PssPTIST3.tf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Tf) (>= 0). Typical value = 0,2." },
6153 AttrDef { id: "PssPTIST3.tp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Tp) (>= 0). Typical value = 0,2." },
6154 ],
6155 },
6156 ClassDef {
6157 ns: "http://iec.ch/TC57/CIM100#",
6158 local: "PssRQB",
6159 qualified: "PssRQB",
6160 super_class: Some(283),
6161 concrete: true,
6162 origins: &["DY"],
6163 comment: "Power system stabilizer type RQB. This power system stabilizer is intended to be used together with excitation system type ExcRQB, which is primarily used in nuclear or thermal generating units.",
6164 attrs: &[
6165 AttrDef { id: "PssRQB.kdpm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead lag gain (KDPM). Typical value = 0,185." },
6166 AttrDef { id: "PssRQB.ki2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Speed input gain (Ki2). Typical value = 3,43." },
6167 AttrDef { id: "PssRQB.ki3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Electrical power input gain (Ki3). Typical value = -11,45." },
6168 AttrDef { id: "PssRQB.ki4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Mechanical power input gain (Ki4). Typical value = 11,86." },
6169 AttrDef { id: "PssRQB.sibv", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Speed deadband (SIBV). Typical value = 0,006." },
6170 AttrDef { id: "PssRQB.t4f", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead lag time constant (T4F) (>= 0). Typical value = 0,045." },
6171 AttrDef { id: "PssRQB.t4m", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input time constant (T4M) (>= 0). Typical value = 5." },
6172 AttrDef { id: "PssRQB.t4mom", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Speed time constant (T4MOM) (>= 0). Typical value = 1,27." },
6173 AttrDef { id: "PssRQB.tomd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Speed delay (TOMD) (>= 0). Typical value = 0,02." },
6174 AttrDef { id: "PssRQB.tomsl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Speed time constant (TOMSL) (>= 0). Typical value = 0,04." },
6175 ],
6176 },
6177 ClassDef {
6178 ns: "http://iec.ch/TC57/CIM100#",
6179 local: "PssSB4",
6180 qualified: "PssSB4",
6181 super_class: Some(283),
6182 concrete: true,
6183 origins: &["DY"],
6184 comment: "Power sensitive stabilizer model.",
6185 attrs: &[
6186 AttrDef { id: "PssSB4.kx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (Kx). Typical value = 2,7." },
6187 AttrDef { id: "PssSB4.ta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Ta) (>= 0). Typical value = 0,37." },
6188 AttrDef { id: "PssSB4.tb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Tb) (>= 0). Typical value = 0,37." },
6189 AttrDef { id: "PssSB4.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Tc) (>= 0). Typical value = 0,035." },
6190 AttrDef { id: "PssSB4.td", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Td) (>= 0). Typical value = 0,0." },
6191 AttrDef { id: "PssSB4.te", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Te) (>= 0). Typical value = 0,0169." },
6192 AttrDef { id: "PssSB4.tt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Tt) (>= 0). Typical value = 0,18." },
6193 AttrDef { id: "PssSB4.tx1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reset time constant (Tx1) (>= 0). Typical value = 0,035." },
6194 AttrDef { id: "PssSB4.tx2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Tx2) (>= 0). Typical value = 5,0." },
6195 AttrDef { id: "PssSB4.vsmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter (Vsmax) (> PssSB4.vsmin). Typical value = 0,062." },
6196 AttrDef { id: "PssSB4.vsmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limiter (Vsmin) (< PssSB4.vsmax). Typical value = -0,062." },
6197 ],
6198 },
6199 ClassDef {
6200 ns: "http://iec.ch/TC57/CIM100#",
6201 local: "PssSH",
6202 qualified: "PssSH",
6203 super_class: Some(283),
6204 concrete: true,
6205 origins: &["DY"],
6206 comment: "SiemensTM “H infinity” power system stabilizer with generator electrical power input. [Footnote: Siemens 'H infinity' power system stabilizers are an example of suitable products available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of these products.]",
6207 attrs: &[
6208 AttrDef { id: "PssSH.k", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Main gain (K). Typical value = 1." },
6209 AttrDef { id: "PssSH.k0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain 0 (K0). Typical value = 0,012." },
6210 AttrDef { id: "PssSH.k1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain 1 (K1). Typical value = 0,488." },
6211 AttrDef { id: "PssSH.k2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain 2 (K2). Typical value = 0,064." },
6212 AttrDef { id: "PssSH.k3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain 3 (K3). Typical value = 0,224." },
6213 AttrDef { id: "PssSH.k4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain 4 (K4). Typical value = 0,1." },
6214 AttrDef { id: "PssSH.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant 1 (T1) (> 0). Typical value = 0,076." },
6215 AttrDef { id: "PssSH.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant 2 (T2) (> 0). Typical value = 0,086." },
6216 AttrDef { id: "PssSH.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant 3 (T3) (> 0). Typical value = 1,068." },
6217 AttrDef { id: "PssSH.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant 4 (T4) (> 0). Typical value = 1,913." },
6218 AttrDef { id: "PssSH.td", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input time constant (Td) (>= 0). Typical value = 10." },
6219 AttrDef { id: "PssSH.vsmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Output maximum limit (Vsmax) (> PssSH.vsmin). Typical value = 0,1." },
6220 AttrDef { id: "PssSH.vsmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Output minimum limit (Vsmin) (< PssSH.vsmax). Typical value = -0,1." },
6221 ],
6222 },
6223 ClassDef {
6224 ns: "http://iec.ch/TC57/CIM100#",
6225 local: "PssSK",
6226 qualified: "PssSK",
6227 super_class: Some(283),
6228 concrete: true,
6229 origins: &["DY"],
6230 comment: "Slovakian PSS with three inputs.",
6231 attrs: &[
6232 AttrDef { id: "PssSK.k1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain P (K1). Typical value = -0,3." },
6233 AttrDef { id: "PssSK.k2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain fE (K2). Typical value = -0,15." },
6234 AttrDef { id: "PssSK.k3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain If (K3). Typical value = 10." },
6235 AttrDef { id: "PssSK.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Denominator time constant (T1) (> 0,005). Typical value = 0,3." },
6236 AttrDef { id: "PssSK.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter time constant (T2) (> 0,005). Typical value = 0,35." },
6237 AttrDef { id: "PssSK.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Denominator time constant (T3) (> 0,005). Typical value = 0,22." },
6238 AttrDef { id: "PssSK.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter time constant (T4) (> 0,005). Typical value = 0,02." },
6239 AttrDef { id: "PssSK.t5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Denominator time constant (T5) (> 0,005). Typical value = 0,02." },
6240 AttrDef { id: "PssSK.t6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter time constant (T6) (> 0,005). Typical value = 0,02." },
6241 AttrDef { id: "PssSK.vsmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer output maximum limit (VSMAX) (> PssSK.vsmin). Typical value = 0,4." },
6242 AttrDef { id: "PssSK.vsmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer output minimum limit (VSMIN) (< PssSK.vsmax). Typical value = -0.4." },
6243 ],
6244 },
6245 ClassDef {
6246 ns: "http://iec.ch/TC57/CIM100#",
6247 local: "PssSTAB2A",
6248 qualified: "PssSTAB2A",
6249 super_class: Some(283),
6250 concrete: true,
6251 origins: &["DY"],
6252 comment: "Power system stabilizer part of an ABB excitation system. [Footnote: ABB excitation systems are an example of suitable products available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of these products.]",
6253 attrs: &[
6254 AttrDef { id: "PssSTAB2A.hlim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer output limiter (HLIM). Typical value = 0,5." },
6255 AttrDef { id: "PssSTAB2A.k2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (K2). Typical value = 1,0." },
6256 AttrDef { id: "PssSTAB2A.k3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (K3). Typical value = 0,25." },
6257 AttrDef { id: "PssSTAB2A.k4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (K4). Typical value = 0,075." },
6258 AttrDef { id: "PssSTAB2A.k5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain (K5). Typical value = 2,5." },
6259 AttrDef { id: "PssSTAB2A.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T2). Typical value = 4,0." },
6260 AttrDef { id: "PssSTAB2A.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T3). Typical value = 2,0." },
6261 AttrDef { id: "PssSTAB2A.t5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (T5). Typical value = 4,5." },
6262 ],
6263 },
6264 ClassDef {
6265 ns: "http://iec.ch/TC57/CIM100#",
6266 local: "PssWECC",
6267 qualified: "PssWECC",
6268 super_class: Some(283),
6269 concrete: true,
6270 origins: &["DY"],
6271 comment: "Dual input power system stabilizer, based on IEEE type 2, with modified output limiter defined by WECC (Western Electricity Coordinating Council, USA).",
6272 attrs: &[
6273 AttrDef { id: "PssWECC.inputSignal1Type", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "InputSignalKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Type of input signal #1 (rotorAngularFrequencyDeviation, busFrequencyDeviation, generatorElectricalPower, generatorAcceleratingPower, busVoltage, or busVoltageDerivative - shall be different than PssWECC.inputSignal2Type). Typical value = rotorAngularFrequencyDeviation." },
6274 AttrDef { id: "PssWECC.inputSignal2Type", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "InputSignalKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Type of input signal #2 (rotorAngularFrequencyDeviation, busFrequencyDeviation, generatorElectricalPower, generatorAcceleratingPower, busVoltage, busVoltageDerivative - shall be different than PssWECC.inputSignal1Type). Typical value = busVoltageDerivative." },
6275 AttrDef { id: "PssWECC.k1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input signal 1 gain (K1). Typical value = 1,13." },
6276 AttrDef { id: "PssWECC.k2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input signal 2 gain (K2). Typical value = 0,0." },
6277 AttrDef { id: "PssWECC.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input signal 1 transducer time constant (T1) (>= 0). Typical value = 0,037." },
6278 AttrDef { id: "PssWECC.t10", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant (T10) (>= 0). Typical value = 0." },
6279 AttrDef { id: "PssWECC.t2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input signal 2 transducer time constant (T2) (>= 0). Typical value = 0,0." },
6280 AttrDef { id: "PssWECC.t3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer washout time constant (T3) (>= 0). Typical value = 9,5." },
6281 AttrDef { id: "PssWECC.t4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stabilizer washout time lag constant (T4) (>= 0). Typical value = 9,5." },
6282 AttrDef { id: "PssWECC.t5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead time constant (T5) (>= 0). Typical value = 1,7." },
6283 AttrDef { id: "PssWECC.t6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant (T6) (>= 0). Typical value = 1,5." },
6284 AttrDef { id: "PssWECC.t7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead time constant (T7) (>= 0). Typical value = 1,7." },
6285 AttrDef { id: "PssWECC.t8", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant (T8) (>= 0). Typical value = 1,5." },
6286 AttrDef { id: "PssWECC.t9", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead time constant (T9) (>= 0). Typical value = 0." },
6287 AttrDef { id: "PssWECC.vcl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum value for voltage compensator output (VCL). Typical value = 0." },
6288 AttrDef { id: "PssWECC.vcu", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum value for voltage compensator output (VCU). Typical value = 0." },
6289 AttrDef { id: "PssWECC.vsmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum output signal (Vsmax) (> PssWECC.vsmin). Typical value = 0,05." },
6290 AttrDef { id: "PssWECC.vsmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum output signal (Vsmin) (< PssWECC.vsmax). Typical value = -0,05." },
6291 ],
6292 },
6293 ClassDef {
6294 ns: "http://iec.ch/TC57/CIM100#",
6295 local: "Quality61850",
6296 qualified: "Quality61850",
6297 super_class: None,
6298 concrete: false,
6299 origins: &["OP"],
6300 comment: "Quality flags in this class are as defined in IEC 61850, except for estimatorReplaced, which has been included in this class for convenience.",
6301 attrs: &[
6302 AttrDef { id: "Quality61850.badReference", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["OP"], comment: "Measurement value may be incorrect due to a reference being out of calibration." },
6303 AttrDef { id: "Quality61850.estimatorReplaced", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["OP"], comment: "Value has been replaced by State Estimator. estimatorReplaced is not an IEC61850 quality bit but has been put in this class for convenience." },
6304 AttrDef { id: "Quality61850.failure", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["OP"], comment: "This identifier indicates that a supervision function has detected an internal or external failure, e.g. communication failure." },
6305 AttrDef { id: "Quality61850.oldData", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["OP"], comment: "Measurement value is old and possibly invalid, as it has not been successfully updated during a specified time interval." },
6306 AttrDef { id: "Quality61850.operatorBlocked", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["OP"], comment: "Measurement value is blocked and hence unavailable for transmission." },
6307 AttrDef { id: "Quality61850.oscillatory", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["OP"], comment: "To prevent some overload of the communication it is sensible to detect and suppress oscillating (fast changing) binary inputs. If a signal changes in a defined time twice in the same direction (from 0 to 1 or from 1 to 0) then oscillation is detected and the detail quality identifier 'oscillatory' is set. If it is detected a configured numbers of transient changes could be passed by. In this time the validity status 'questionable' is set. If after this defined numbers of changes the signal is still in the oscillating state the value shall be set either to the opposite state of the previous stable value or to a defined default value. In this case the validity status 'questionable' is reset and 'invalid' is set as long as the signal is oscillating. If it is configured such that no transient changes should be passed by then the validity status 'invalid' is set immediately in addition to the detail quality identifier 'oscillatory' (used for status information only)." },
6308 AttrDef { id: "Quality61850.outOfRange", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["OP"], comment: "Measurement value is beyond a predefined range of value." },
6309 AttrDef { id: "Quality61850.overFlow", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["OP"], comment: "Measurement value is beyond the capability of being represented properly. For example, a counter value overflows from maximum count back to a value of zero." },
6310 AttrDef { id: "Quality61850.source", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "Source", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["OP"], comment: "Source gives information related to the origin of a value. The value may be acquired from the process, defaulted or substituted." },
6311 AttrDef { id: "Quality61850.suspect", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["OP"], comment: "A correlation function has detected that the value is not consistent with other values. Typically set by a network State Estimator." },
6312 AttrDef { id: "Quality61850.test", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["OP"], comment: "Measurement value is transmitted for test purposes." },
6313 AttrDef { id: "Quality61850.validity", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "Validity", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["OP"], comment: "Validity of the measurement value." },
6314 ],
6315 },
6316 ClassDef {
6317 ns: "http://iec.ch/TC57/CIM100#",
6318 local: "RaiseLowerCommand",
6319 qualified: "RaiseLowerCommand",
6320 super_class: Some(11),
6321 concrete: true,
6322 origins: &["OP"],
6323 comment: "An analog control that increases or decreases a set point value with pulses. Unless otherwise specified, one pulse moves the set point by one.",
6324 attrs: &[
6325 AttrDef { id: "RaiseLowerCommand.ValueAliasSet", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ValueAliasSet", is_list: false, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "The ValueAliasSet used for translation of a Control value to a name." },
6326 ],
6327 },
6328 ClassDef {
6329 ns: "http://iec.ch/TC57/CIM100#",
6330 local: "RatioTapChanger",
6331 qualified: "RatioTapChanger",
6332 super_class: Some(362),
6333 concrete: true,
6334 origins: &["EQ", "SSH"],
6335 comment: "A tap changer that changes the voltage ratio impacting the voltage magnitude but not the phase angle across the transformer. Angle sign convention (general): Positive value indicates a positive phase shift from the winding where the tap is located to the other winding (for a two-winding transformer).",
6336 attrs: &[
6337 AttrDef { id: "RatioTapChanger.RatioTapChangerTable", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RatioTapChangerTable", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The tap ratio table for this ratio tap changer." },
6338 AttrDef { id: "RatioTapChanger.TransformerEnd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TransformerEnd", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "Transformer end to which this ratio tap changer belongs." },
6339 AttrDef { id: "RatioTapChanger.stepVoltageIncrement", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PerCent", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Tap step increment, in per cent of rated voltage of the power transformer end, per step position. When the increment is negative, the voltage decreases when the tap step increases." },
6340 ],
6341 },
6342 ClassDef {
6343 ns: "http://iec.ch/TC57/CIM100#",
6344 local: "RatioTapChangerTable",
6345 qualified: "RatioTapChangerTable",
6346 super_class: Some(213),
6347 concrete: true,
6348 origins: &["EQ"],
6349 comment: "Describes a curve for how the voltage magnitude and impedance varies with the tap step.",
6350 attrs: &[
6351 AttrDef { id: "RatioTapChangerTable.RatioTapChanger", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RatioTapChanger", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The ratio tap changer of this tap ratio table." },
6352 AttrDef { id: "RatioTapChangerTable.RatioTapChangerTablePoint", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RatioTapChangerTablePoint", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "Points of this table." },
6353 ],
6354 },
6355 ClassDef {
6356 ns: "http://iec.ch/TC57/CIM100#",
6357 local: "RatioTapChangerTablePoint",
6358 qualified: "RatioTapChangerTablePoint",
6359 super_class: Some(364),
6360 concrete: true,
6361 origins: &["EQ"],
6362 comment: "Describes each tap step in the ratio tap changer tabular curve.",
6363 attrs: &[
6364 AttrDef { id: "RatioTapChangerTablePoint.RatioTapChangerTable", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RatioTapChangerTable", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "Table of this point." },
6365 ],
6366 },
6367 ClassDef {
6368 ns: "http://iec.ch/TC57/CIM100#",
6369 local: "ReactiveCapabilityCurve",
6370 qualified: "ReactiveCapabilityCurve",
6371 super_class: Some(53),
6372 concrete: true,
6373 origins: &["EQ"],
6374 comment: "Reactive power rating envelope versus the synchronous machine's active power, in both the generating and motoring modes. For each active power value there is a corresponding high and low reactive power limit value. Typically there will be a separate curve for each coolant condition, such as hydrogen pressure. The Y1 axis values represent reactive minimum and the Y2 axis values represent reactive maximum.",
6375 attrs: &[
6376 AttrDef { id: "ReactiveCapabilityCurve.EquivalentInjection", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "EquivalentInjection", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The equivalent injection using this reactive capability curve." },
6377 AttrDef { id: "ReactiveCapabilityCurve.InitiallyUsedBySynchronousMachines", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SynchronousMachine", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "Synchronous machines using this curve as default." },
6378 ],
6379 },
6380 ClassDef {
6381 ns: "http://iec.ch/TC57/CIM100#",
6382 local: "RegularIntervalSchedule",
6383 qualified: "RegularIntervalSchedule",
6384 super_class: Some(23),
6385 concrete: false,
6386 origins: &["EQ"],
6387 comment: "The schedule has time points where the time between them is constant.",
6388 attrs: &[
6389 AttrDef { id: "RegularIntervalSchedule.TimePoints", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RegularTimePoint", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The regular interval time point data values that define this schedule." },
6390 AttrDef { id: "RegularIntervalSchedule.endTime", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "DateTime", is_list: false, used: true, xsd: "dateTime", value_ns: "", origins: &["EQ"], comment: "The time for the last time point. The value can be a time of day, not a specific date." },
6391 AttrDef { id: "RegularIntervalSchedule.timeStep", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The time between each pair of subsequent regular time points in sequence order." },
6392 ],
6393 },
6394 ClassDef {
6395 ns: "http://iec.ch/TC57/CIM100#",
6396 local: "RegularTimePoint",
6397 qualified: "RegularTimePoint",
6398 super_class: None,
6399 concrete: true,
6400 origins: &["EQ"],
6401 comment: "Time point for a schedule where the time between the consecutive points is constant.",
6402 attrs: &[
6403 AttrDef { id: "RegularTimePoint.IntervalSchedule", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RegularIntervalSchedule", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "Regular interval schedule containing this time point." },
6404 AttrDef { id: "RegularTimePoint.sequenceNumber", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["EQ"], comment: "The position of the regular time point in the sequence. Note that time points don't have to be sequential, i.e. time points may be omitted. The actual time for a RegularTimePoint is computed by multiplying the associated regular interval schedule's time step with the regular time point sequence number and adding the associated schedules start time. To specify values for the start time, use sequence number 0. The sequence number cannot be negative." },
6405 AttrDef { id: "RegularTimePoint.value1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The first value at the time. The meaning of the value is defined by the derived type of the associated schedule." },
6406 AttrDef { id: "RegularTimePoint.value2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The second value at the time. The meaning of the value is defined by the derived type of the associated schedule." },
6407 ],
6408 },
6409 ClassDef {
6410 ns: "http://iec.ch/TC57/CIM100#",
6411 local: "RegulatingCondEq",
6412 qualified: "RegulatingCondEq",
6413 super_class: Some(94),
6414 concrete: false,
6415 origins: &["EQ", "DY", "SC", "SSH"],
6416 comment: "A type of conducting equipment that can regulate a quantity (i.e. voltage or flow) at a specific point in the network.",
6417 attrs: &[
6418 AttrDef { id: "RegulatingCondEq.RegulatingControl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RegulatingControl", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The regulating control scheme in which this equipment participates." },
6419 AttrDef { id: "RegulatingCondEq.controlEnabled", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["SSH"], comment: "Specifies the regulation status of the equipment. True is regulating, false is not regulating." },
6420 ],
6421 },
6422 ClassDef {
6423 ns: "http://iec.ch/TC57/CIM100#",
6424 local: "RegulatingControl",
6425 qualified: "RegulatingControl",
6426 super_class: Some(282),
6427 concrete: true,
6428 origins: &["EQ", "SSH"],
6429 comment: "Specifies a set of equipment that works together to control a power system quantity such as voltage or flow. Remote bus voltage control is possible by specifying the controlled terminal located at some place remote from the controlling equipment. The specified terminal shall be associated with the connectivity node of the controlled point. The most specific subtype of RegulatingControl shall be used in case such equipment participate in the control, e.g. TapChangerControl for tap changers. For flow control, load sign convention is used, i.e. positive sign means flow out from a TopologicalNode (bus) into the conducting equipment. The attribute minAllowedTargetValue and maxAllowedTargetValue are required in the following cases: - For a power generating module operated in power factor control mode to specify maximum and minimum power factor values; - Whenever it is necessary to have an off center target voltage for the tap changer regulator. For instance, due to long cables to off shore wind farms and the need to have a simpler setup at the off shore transformer platform, the voltage is controlled from the land at the connection point for the off shore wind farm. Since there usually is a voltage rise along the cable, there is typical and overvoltage of up 3-4 kV compared to the on shore station. Thus in normal operation the tap changer on the on shore station is operated with a target set point, which is in the lower parts of the dead band. The attributes minAllowedTargetValue and maxAllowedTargetValue are not related to the attribute targetDeadband and thus they are not treated as an alternative of the targetDeadband. They are needed due to limitations in the local substation controller. The attribute targetDeadband is used to prevent the power flow from move the tap position in circles (hunting) that is to be used regardless of the attributes minAllowedTargetValue and maxAllowedTargetValue.",
6430 attrs: &[
6431 AttrDef { id: "RegulatingControl.RegulatingCondEq", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RegulatingCondEq", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The equipment that participates in this regulating control scheme." },
6432 AttrDef { id: "RegulatingControl.RegulationSchedule", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RegulationSchedule", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "Schedule for this regulating control." },
6433 AttrDef { id: "RegulatingControl.Terminal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Terminal", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The terminal associated with this regulating control. The terminal is associated instead of a node, since the terminal could connect into either a topological node or a connectivity node. Sometimes it is useful to model regulation at a terminal of a bus bar object." },
6434 AttrDef { id: "RegulatingControl.discrete", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["SSH"], comment: "The regulation is performed in a discrete mode. This applies to equipment with discrete controls, e.g. tap changers and shunt compensators." },
6435 AttrDef { id: "RegulatingControl.enabled", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["SSH"], comment: "The flag tells if regulation is enabled." },
6436 AttrDef { id: "RegulatingControl.maxAllowedTargetValue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Maximum allowed target value (RegulatingControl.targetValue)." },
6437 AttrDef { id: "RegulatingControl.minAllowedTargetValue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Minimum allowed target value (RegulatingControl.targetValue)." },
6438 AttrDef { id: "RegulatingControl.mode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "RegulatingControlModeKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "The regulating control mode presently available. This specification allows for determining the kind of regulation without need for obtaining the units from a schedule." },
6439 AttrDef { id: "RegulatingControl.targetDeadband", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "This is a deadband used with discrete control to avoid excessive update of controls like tap changers and shunt compensator banks while regulating. The units of those appropriate for the mode. The attribute shall be a positive value or zero. If RegulatingControl.discrete is set to 'false', the RegulatingControl.targetDeadband is to be ignored. Note that for instance, if the targetValue is 100 kV and the targetDeadband is 2 kV the range is from 99 to 101 kV." },
6440 AttrDef { id: "RegulatingControl.targetValue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "The target value specified for case input. This value can be used for the target value without the use of schedules. The value has the units appropriate to the mode attribute." },
6441 AttrDef { id: "RegulatingControl.targetValueUnitMultiplier", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "UnitMultiplier", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["SSH"], comment: "Specify the multiplier for used for the targetValue." },
6442 ],
6443 },
6444 ClassDef {
6445 ns: "http://iec.ch/TC57/CIM100#",
6446 local: "RegulationSchedule",
6447 qualified: "RegulationSchedule",
6448 super_class: Some(325),
6449 concrete: true,
6450 origins: &["EQ"],
6451 comment: "A pre-established pattern over time for a controlled variable, e.g., busbar voltage.",
6452 attrs: &[
6453 AttrDef { id: "RegulationSchedule.RegulatingControl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RegulatingControl", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "Regulating controls that have this schedule." },
6454 ],
6455 },
6456 ClassDef {
6457 ns: "http://iec.ch/TC57/CIM100#",
6458 local: "RemoteInputSignal",
6459 qualified: "RemoteInputSignal",
6460 super_class: Some(213),
6461 concrete: true,
6462 origins: &["DY"],
6463 comment: "Supports connection to a terminal associated with a remote bus from which an input signal of a specific type is coming.",
6464 attrs: &[
6465 AttrDef { id: "RemoteInputSignal.DiscontinuousExcitationControlDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DiscontinuousExcitationControlDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Discontinuous excitation control model using this remote input signal." },
6466 AttrDef { id: "RemoteInputSignal.PFVArControllerType1Dynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PFVArControllerType1Dynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Power factor or VAr controller type 1 model using this remote input signal." },
6467 AttrDef { id: "RemoteInputSignal.PowerSystemStabilizerDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PowerSystemStabilizerDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Power system stabilizer model using this remote input signal." },
6468 AttrDef { id: "RemoteInputSignal.Terminal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Terminal", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Remote terminal with which this input signal is associated." },
6469 AttrDef { id: "RemoteInputSignal.UnderexcitationLimiterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "UnderexcitationLimiterDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Underexcitation limiter model using this remote input signal." },
6470 AttrDef { id: "RemoteInputSignal.VoltageCompensatorDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "VoltageCompensatorDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Voltage compensator model using this remote input signal." },
6471 AttrDef { id: "RemoteInputSignal.WindPlantDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindPlantDynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "The wind plant using the remote signal." },
6472 AttrDef { id: "RemoteInputSignal.WindTurbineType1or2Dynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType1or2Dynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind generator type 1 or type 2 model using this remote input signal." },
6473 AttrDef { id: "RemoteInputSignal.WindTurbineType3or4Dynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType3or4Dynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 3 or type 4 models using this remote input signal." },
6474 AttrDef { id: "RemoteInputSignal.remoteSignalType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "RemoteSignalKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Type of input signal." },
6475 ],
6476 },
6477 ClassDef {
6478 ns: "http://iec.ch/TC57/CIM100#",
6479 local: "ReportingGroup",
6480 qualified: "ReportingGroup",
6481 super_class: Some(213),
6482 concrete: true,
6483 origins: &["EQ", "TP"],
6484 comment: "A reporting group is used for various ad-hoc groupings used for reporting.",
6485 attrs: &[
6486 AttrDef { id: "ReportingGroup.BusNameMarker", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "BusNameMarker", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The bus name markers that belong to this reporting group." },
6487 AttrDef { id: "ReportingGroup.TopologicalNode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TopologicalNode", is_list: true, used: false, xsd: "", value_ns: "", origins: &["TP"], comment: "The topological nodes that belong to the reporting group." },
6488 ],
6489 },
6490 ClassDef {
6491 ns: "http://iec.ch/TC57/CIM100#",
6492 local: "RotatingMachine",
6493 qualified: "RotatingMachine",
6494 super_class: Some(315),
6495 concrete: false,
6496 origins: &["EQ", "DY", "SC", "SSH"],
6497 comment: "A rotating machine which may be used as a generator or motor.",
6498 attrs: &[
6499 AttrDef { id: "RotatingMachine.GeneratingUnit", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "GeneratingUnit", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "A synchronous machine may operate as a generator and as such becomes a member of a generating unit." },
6500 AttrDef { id: "RotatingMachine.HydroPump", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "HydroPump", is_list: false, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The synchronous machine drives the turbine which moves the water from a low elevation to a higher elevation. The direction of machine rotation for pumping may or may not be the same as for generating." },
6501 AttrDef { id: "RotatingMachine.p", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Active power injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for a steady state solution." },
6502 AttrDef { id: "RotatingMachine.q", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Reactive power injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for a steady state solution." },
6503 AttrDef { id: "RotatingMachine.ratedPowerFactor", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Power factor (nameplate data). It is primarily used for short circuit data exchange according to IEC 60909. The attribute cannot be a negative value." },
6504 AttrDef { id: "RotatingMachine.ratedS", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ApparentPower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Nameplate apparent power rating for the unit. The attribute shall have a positive value." },
6505 AttrDef { id: "RotatingMachine.ratedU", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Rated voltage (nameplate data, Ur in IEC 60909-0). It is primarily used for short circuit data exchange according to IEC 60909. The attribute shall be a positive value." },
6506 ],
6507 },
6508 ClassDef {
6509 ns: "http://iec.ch/TC57/CIM100#",
6510 local: "RotatingMachineDynamics",
6511 qualified: "RotatingMachineDynamics",
6512 super_class: Some(91),
6513 concrete: false,
6514 origins: &["DY"],
6515 comment: "Abstract parent class for all synchronous and asynchronous machine standard models.",
6516 attrs: &[
6517 AttrDef { id: "RotatingMachineDynamics.damping", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Damping torque coefficient (D) (>= 0). A proportionality constant that, when multiplied by the angular velocity of the rotor poles with respect to the magnetic field (frequency), results in the damping torque. This value is often zero when the sources of damping torques (generator damper windings, load damping effects, etc.) are modelled in detail. Typical value = 0." },
6518 AttrDef { id: "RotatingMachineDynamics.inertia", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Inertia constant of generator or motor and mechanical load (H) (> 0). This is the specification for the stored energy in the rotating mass when operating at rated speed. For a generator, this includes the generator plus all other elements (turbine, exciter) on the same shaft and has units of MW x s. For a motor, it includes the motor plus its mechanical load. Conventional units are PU on the generator MVA base, usually expressed as MW x s / MVA or just s. This value is used in the accelerating power reference frame for operator training simulator solutions. Typical value = 3." },
6519 AttrDef { id: "RotatingMachineDynamics.saturationFactor", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Saturation factor at rated terminal voltage (S1) (>= 0). Not used by simplified model. Defined by defined by S(E1) in the SynchronousMachineSaturationParameters diagram. Typical value = 0,02." },
6520 AttrDef { id: "RotatingMachineDynamics.saturationFactor120", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Saturation factor at 120% of rated terminal voltage (S12) (>= RotatingMachineDynamics.saturationFactor). Not used by the simplified model, defined by S(E2) in the SynchronousMachineSaturationParameters diagram. Typical value = 0,12." },
6521 AttrDef { id: "RotatingMachineDynamics.statorLeakageReactance", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stator leakage reactance (Xl) (>= 0). Typical value = 0,15." },
6522 AttrDef { id: "RotatingMachineDynamics.statorResistance", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Stator (armature) resistance (Rs) (>= 0). Typical value = 0,005." },
6523 ],
6524 },
6525 ClassDef {
6526 ns: "http://iec.ch/TC57/CIM100#",
6527 local: "SVCControlMode",
6528 qualified: "SVCControlMode",
6529 super_class: None,
6530 concrete: false,
6531 origins: &["EQ"],
6532 comment: "Static VAr Compensator control mode.",
6533 attrs: &[],
6534 },
6535 ClassDef {
6536 ns: "http://iec.ch/TC57/CIM100#",
6537 local: "SVCUserDefined",
6538 qualified: "SVCUserDefined",
6539 super_class: Some(335),
6540 concrete: true,
6541 origins: &["DY"],
6542 comment: "Static var compensator (SVC) function block whose dynamic behaviour is described by a user-defined model.",
6543 attrs: &[
6544 AttrDef { id: "SVCUserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
6545 AttrDef { id: "SVCUserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
6546 ],
6547 },
6548 ClassDef {
6549 ns: "http://iec.ch/TC57/CIM100#",
6550 local: "Season",
6551 qualified: "Season",
6552 super_class: Some(213),
6553 concrete: true,
6554 origins: &["EQ"],
6555 comment: "A specified time period of the year.",
6556 attrs: &[
6557 AttrDef { id: "Season.SeasonDayTypeSchedules", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SeasonDayTypeSchedule", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "Schedules that use this Season." },
6558 AttrDef { id: "Season.endDate", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "MonthDay", is_list: false, used: true, xsd: "gMonthDay", value_ns: "", origins: &["EQ"], comment: "Date season ends." },
6559 AttrDef { id: "Season.startDate", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "MonthDay", is_list: false, used: true, xsd: "gMonthDay", value_ns: "", origins: &["EQ"], comment: "Date season starts." },
6560 ],
6561 },
6562 ClassDef {
6563 ns: "http://iec.ch/TC57/CIM100#",
6564 local: "SeasonDayTypeSchedule",
6565 qualified: "SeasonDayTypeSchedule",
6566 super_class: Some(313),
6567 concrete: false,
6568 origins: &["EQ"],
6569 comment: "A time schedule covering a 24 hour period, with curve data for a specific type of season and day.",
6570 attrs: &[
6571 AttrDef { id: "SeasonDayTypeSchedule.DayType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DayType", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "DayType for the Schedule." },
6572 AttrDef { id: "SeasonDayTypeSchedule.Season", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Season", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "Season for the Schedule." },
6573 ],
6574 },
6575 ClassDef {
6576 ns: "http://iec.ch/TC57/CIM100#",
6577 local: "Sensor",
6578 qualified: "Sensor",
6579 super_class: Some(21),
6580 concrete: false,
6581 origins: &["EQ"],
6582 comment: "This class describe devices that transform a measured quantity into signals that can be presented at displays, used in control or be recorded.",
6583 attrs: &[],
6584 },
6585 ClassDef {
6586 ns: "http://iec.ch/TC57/CIM100#",
6587 local: "SeriesCompensator",
6588 qualified: "SeriesCompensator",
6589 super_class: Some(37),
6590 concrete: true,
6591 origins: &["EQ", "SC"],
6592 comment: "A Series Compensator is a series capacitor or reactor or an AC transmission line without charging susceptance. It is a two terminal device.",
6593 attrs: &[
6594 AttrDef { id: "SeriesCompensator.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Positive sequence resistance." },
6595 AttrDef { id: "SeriesCompensator.r0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence resistance." },
6596 AttrDef { id: "SeriesCompensator.varistorPresent", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["SC"], comment: "Describe if a metal oxide varistor (mov) for over voltage protection is configured in parallel with the series compensator. It is used for short circuit calculations." },
6597 AttrDef { id: "SeriesCompensator.varistorRatedCurrent", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "CurrentFlow", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "The maximum current the varistor is designed to handle at specified duration. It is used for short circuit calculations and exchanged only if SeriesCompensator.varistorPresent is true. The attribute shall be a positive value." },
6598 AttrDef { id: "SeriesCompensator.varistorVoltageThreshold", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "The dc voltage at which the varistor starts conducting. It is used for short circuit calculations and exchanged only if SeriesCompensator.varistorPresent is true." },
6599 AttrDef { id: "SeriesCompensator.x", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Positive sequence reactance." },
6600 AttrDef { id: "SeriesCompensator.x0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence reactance." },
6601 ],
6602 },
6603 ClassDef {
6604 ns: "http://iec.ch/TC57/CIM100#",
6605 local: "ServiceLocation",
6606 qualified: "ServiceLocation",
6607 super_class: Some(445),
6608 concrete: true,
6609 origins: &["GL"],
6610 comment: "A real estate location, commonly referred to as premises.",
6611 attrs: &[],
6612 },
6613 ClassDef {
6614 ns: "http://iec.ch/TC57/CIM100#",
6615 local: "SetPoint",
6616 qualified: "SetPoint",
6617 super_class: Some(11),
6618 concrete: true,
6619 origins: &["OP"],
6620 comment: "An analog control that issues a set point value.",
6621 attrs: &[
6622 AttrDef { id: "SetPoint.normalValue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["OP"], comment: "Normal value for Control.value e.g. used for percentage scaling." },
6623 AttrDef { id: "SetPoint.value", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["OP"], comment: "The value representing the actuator output." },
6624 ],
6625 },
6626 ClassDef {
6627 ns: "http://iec.ch/TC57/CIM100#",
6628 local: "ShuntCompensator",
6629 qualified: "ShuntCompensator",
6630 super_class: Some(315),
6631 concrete: false,
6632 origins: &["EQ", "SC", "SSH", "SV"],
6633 comment: "A shunt capacitor or reactor or switchable bank of shunt capacitors or reactors. A section of a shunt compensator is an individual capacitor or reactor. A negative value for bPerSection indicates that the compensator is a reactor. ShuntCompensator is a single terminal device. Ground is implied.",
6634 attrs: &[
6635 AttrDef { id: "ShuntCompensator.SvShuntCompensatorSections", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SvShuntCompensatorSections", is_list: false, used: false, xsd: "", value_ns: "", origins: &["SV"], comment: "The state for the number of shunt compensator sections in service." },
6636 AttrDef { id: "ShuntCompensator.aVRDelay", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "An automatic voltage regulation delay (AVRDelay) which is the time delay from a change in voltage to when the capacitor is allowed to change state. This filters out temporary changes in voltage." },
6637 AttrDef { id: "ShuntCompensator.grounded", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["EQ"], comment: "Used for Yn and Zn connections. True if the neutral is solidly grounded." },
6638 AttrDef { id: "ShuntCompensator.maximumSections", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["EQ"], comment: "The maximum number of sections that may be switched in." },
6639 AttrDef { id: "ShuntCompensator.nomU", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The voltage at which the nominal reactive power may be calculated. This should normally be within 10% of the voltage at which the capacitor is connected to the network." },
6640 AttrDef { id: "ShuntCompensator.normalSections", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["EQ"], comment: "The normal number of sections switched in. The value shall be between zero and ShuntCompensator.maximumSections." },
6641 AttrDef { id: "ShuntCompensator.sections", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Shunt compensator sections in use. Starting value for steady state solution. The attribute shall be a positive value or zero. Non integer values are allowed to support continuous variables. The reasons for continuous value are to support study cases where no discrete shunt compensators has yet been designed, a solutions where a narrow voltage band force the sections to oscillate or accommodate for a continuous solution as input. For LinearShuntConpensator the value shall be between zero and ShuntCompensator.maximumSections. At value zero the shunt compensator conductance and admittance is zero. Linear interpolation of conductance and admittance between the previous and next integer section is applied in case of non-integer values. For NonlinearShuntCompensator-s shall only be set to one of the NonlinearShuntCompenstorPoint.sectionNumber. There is no interpolation between NonlinearShuntCompenstorPoint-s." },
6642 AttrDef { id: "ShuntCompensator.voltageSensitivity", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "VoltagePerReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Voltage sensitivity required for the device to regulate the bus voltage, in voltage/reactive power." },
6643 ],
6644 },
6645 ClassDef {
6646 ns: "http://iec.ch/TC57/CIM100#",
6647 local: "SolarGeneratingUnit",
6648 qualified: "SolarGeneratingUnit",
6649 super_class: Some(169),
6650 concrete: true,
6651 origins: &["EQ", "SSH"],
6652 comment: "A solar thermal generating unit, connected to the grid by means of a rotating machine. This class does not represent photovoltaic (PV) generation.",
6653 attrs: &[
6654 AttrDef { id: "SolarGeneratingUnit.SolarPowerPlant", ns: "http://iec.ch/TC57/CIM100-European#", kind: AttrKind::Association, range: "SolarPowerPlant", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "A solar power plant may have solar generating units." },
6655 ],
6656 },
6657 ClassDef {
6658 ns: "http://iec.ch/TC57/CIM100-European#",
6659 local: "SolarPowerPlant",
6660 qualified: "SolarPowerPlant",
6661 super_class: Some(282),
6662 concrete: true,
6663 origins: &["EQ"],
6664 comment: "Solar power plant.",
6665 attrs: &[
6666 AttrDef { id: "SolarPowerPlant.SolarGeneratingUnits", ns: "http://iec.ch/TC57/CIM100-European#", kind: AttrKind::Association, range: "SolarGeneratingUnit", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "A solar generating unit or units may be a member of a solar power plant." },
6667 ],
6668 },
6669 ClassDef {
6670 ns: "http://www.w3.org/1999/02/22-rdf-syntax-ns#",
6671 local: "Statements",
6672 qualified: "Statements",
6673 super_class: None,
6674 concrete: false,
6675 origins: &["FH"],
6676 comment: "It represent a set of Definition and/or Description elements.",
6677 attrs: &[
6678 AttrDef { id: "Statements.object", ns: "http://www.w3.org/1999/02/22-rdf-syntax-ns#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["FH"], comment: "Statement object." },
6679 AttrDef { id: "Statements.predicate", ns: "http://www.w3.org/1999/02/22-rdf-syntax-ns#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["FH"], comment: "Statement predicate." },
6680 AttrDef { id: "Statements.subject", ns: "http://www.w3.org/1999/02/22-rdf-syntax-ns#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["FH"], comment: "Statement subject." },
6681 ],
6682 },
6683 ClassDef {
6684 ns: "http://iec.ch/TC57/CIM100#",
6685 local: "StaticVarCompensator",
6686 qualified: "StaticVarCompensator",
6687 super_class: Some(315),
6688 concrete: true,
6689 origins: &["EQ", "DY", "SSH"],
6690 comment: "A facility for providing variable and controllable shunt reactive power. The SVC typically consists of a stepdown transformer, filter, thyristor-controlled reactor, and thyristor-switched capacitor arms. The SVC may operate in fixed MVar output mode or in voltage control mode. When in voltage control mode, the output of the SVC will be proportional to the deviation of voltage at the controlled bus from the voltage setpoint. The SVC characteristic slope defines the proportion. If the voltage at the controlled bus is equal to the voltage setpoint, the SVC MVar output is zero.",
6691 attrs: &[
6692 AttrDef { id: "StaticVarCompensator.StaticVarCompensatorDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "StaticVarCompensatorDynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Static Var Compensator dynamics model used to describe dynamic behaviour of this Static Var Compensator." },
6693 AttrDef { id: "StaticVarCompensator.capacitiveRating", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Capacitive reactance at maximum capacitive reactive power. Shall always be positive." },
6694 AttrDef { id: "StaticVarCompensator.inductiveRating", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Inductive reactance at maximum inductive reactive power. Shall always be negative." },
6695 AttrDef { id: "StaticVarCompensator.q", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Reactive power injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for a steady state solution." },
6696 AttrDef { id: "StaticVarCompensator.sVCControlMode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SVCControlMode", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "SVC control mode." },
6697 AttrDef { id: "StaticVarCompensator.slope", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "VoltagePerReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The characteristics slope of an SVC defines how the reactive power output changes in proportion to the difference between the regulated bus voltage and the voltage setpoint. The attribute shall be a positive value or zero." },
6698 AttrDef { id: "StaticVarCompensator.voltageSetPoint", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The reactive power output of the SVC is proportional to the difference between the voltage at the regulated bus and the voltage setpoint. When the regulated bus voltage is equal to the voltage setpoint, the reactive power output is zero." },
6699 ],
6700 },
6701 ClassDef {
6702 ns: "http://iec.ch/TC57/CIM100#",
6703 local: "StaticVarCompensatorDynamics",
6704 qualified: "StaticVarCompensatorDynamics",
6705 super_class: Some(91),
6706 concrete: false,
6707 origins: &["DY"],
6708 comment: "Static var compensator whose behaviour is described by reference to a standard model or by definition of a user-defined model.",
6709 attrs: &[
6710 AttrDef { id: "StaticVarCompensatorDynamics.StaticVarCompensator", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "StaticVarCompensator", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Static Var Compensator to which Static Var Compensator dynamics model applies." },
6711 ],
6712 },
6713 ClassDef {
6714 ns: "http://iec.ch/TC57/CIM100#",
6715 local: "StationSupply",
6716 qualified: "StationSupply",
6717 super_class: Some(95),
6718 concrete: true,
6719 origins: &["EQ", "SSH"],
6720 comment: "Station supply with load derived from the station output.",
6721 attrs: &[],
6722 },
6723 ClassDef {
6724 ns: "http://iec.ch/TC57/CIM100#",
6725 local: "Status",
6726 qualified: "Status",
6727 super_class: None,
6728 concrete: false,
6729 origins: &["GL"],
6730 comment: "Current status information relevant to an entity.",
6731 attrs: &[
6732 AttrDef { id: "Status.dateTime", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "DateTime", is_list: false, used: true, xsd: "dateTime", value_ns: "", origins: &["GL"], comment: "Date and time for which status 'value' applies." },
6733 AttrDef { id: "Status.reason", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "Reason code or explanation for why an object went to the current status 'value'." },
6734 AttrDef { id: "Status.remark", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "Pertinent information regarding the current 'value', as free form text." },
6735 AttrDef { id: "Status.value", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "Status value at 'dateTime'; prior status changes may have been kept in instances of activity records associated with the object to which this status applies." },
6736 ],
6737 },
6738 ClassDef {
6739 ns: "http://iec.ch/TC57/CIM100#",
6740 local: "StreetAddress",
6741 qualified: "StreetAddress",
6742 super_class: None,
6743 concrete: false,
6744 origins: &["GL"],
6745 comment: "General purpose street and postal address information.",
6746 attrs: &[
6747 AttrDef { id: "StreetAddress.language", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "The language in which the address is specified, using ISO 639-1 two digit language code." },
6748 AttrDef { id: "StreetAddress.poBox", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "Post office box." },
6749 AttrDef { id: "StreetAddress.postalCode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "Postal code for the address." },
6750 AttrDef { id: "StreetAddress.status", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Status", is_list: false, used: true, xsd: "", value_ns: "", origins: &["GL"], comment: "Status of this address." },
6751 AttrDef { id: "StreetAddress.streetDetail", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "StreetDetail", is_list: false, used: true, xsd: "", value_ns: "", origins: &["GL"], comment: "Street detail." },
6752 AttrDef { id: "StreetAddress.townDetail", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TownDetail", is_list: false, used: true, xsd: "", value_ns: "", origins: &["GL"], comment: "Town detail." },
6753 ],
6754 },
6755 ClassDef {
6756 ns: "http://iec.ch/TC57/CIM100#",
6757 local: "StreetDetail",
6758 qualified: "StreetDetail",
6759 super_class: None,
6760 concrete: false,
6761 origins: &["GL"],
6762 comment: "Street details, in the context of address.",
6763 attrs: &[
6764 AttrDef { id: "StreetDetail.addressGeneral", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "First line of a free form address or some additional address information (for example a mail stop)." },
6765 AttrDef { id: "StreetDetail.addressGeneral2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "(if applicable) Second line of a free form address." },
6766 AttrDef { id: "StreetDetail.addressGeneral3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "(if applicable) Third line of a free form address." },
6767 AttrDef { id: "StreetDetail.buildingName", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "(if applicable) In certain cases the physical location of the place of interest does not have a direct point of entry from the street, but may be located inside a larger structure such as a building, complex, office block, apartment, etc." },
6768 AttrDef { id: "StreetDetail.code", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "(if applicable) Utilities often make use of external reference systems, such as those of the town-planner's department or surveyor general's mapping system, that allocate global reference codes to streets." },
6769 AttrDef { id: "StreetDetail.floorIdentification", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "The identification by name or number, expressed as text, of the floor in the building as part of this address." },
6770 AttrDef { id: "StreetDetail.name", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "Name of the street." },
6771 AttrDef { id: "StreetDetail.number", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "Designator of the specific location on the street." },
6772 AttrDef { id: "StreetDetail.prefix", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "Prefix to the street name. For example: North, South, East, West." },
6773 AttrDef { id: "StreetDetail.suffix", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "Suffix to the street name. For example: North, South, East, West." },
6774 AttrDef { id: "StreetDetail.suiteNumber", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "Number of the apartment or suite." },
6775 AttrDef { id: "StreetDetail.type", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "Type of street. Examples include: street, circle, boulevard, avenue, road, drive, etc." },
6776 AttrDef { id: "StreetDetail.withinTownLimits", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["GL"], comment: "True if this street is within the legal geographical boundaries of the specified town (default)." },
6777 ],
6778 },
6779 ClassDef {
6780 ns: "http://iec.ch/TC57/CIM100#",
6781 local: "StringMeasurement",
6782 qualified: "StringMeasurement",
6783 super_class: Some(233),
6784 concrete: true,
6785 origins: &["OP"],
6786 comment: "StringMeasurement represents a measurement with values of type string.",
6787 attrs: &[
6788 AttrDef { id: "StringMeasurement.StringMeasurementValues", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "StringMeasurementValue", is_list: true, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "The values connected to this measurement." },
6789 ],
6790 },
6791 ClassDef {
6792 ns: "http://iec.ch/TC57/CIM100#",
6793 local: "StringMeasurementValue",
6794 qualified: "StringMeasurementValue",
6795 super_class: Some(234),
6796 concrete: true,
6797 origins: &["OP"],
6798 comment: "StringMeasurementValue represents a measurement value of type string.",
6799 attrs: &[
6800 AttrDef { id: "StringMeasurementValue.StringMeasurement", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "StringMeasurement", is_list: false, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "Measurement to which this value is connected." },
6801 ],
6802 },
6803 ClassDef {
6804 ns: "http://iec.ch/TC57/CIM100#",
6805 local: "SubGeographicalRegion",
6806 qualified: "SubGeographicalRegion",
6807 super_class: Some(213),
6808 concrete: true,
6809 origins: &["EQ", "EQBD"],
6810 comment: "A subset of a geographical region of a power system network model.",
6811 attrs: &[
6812 AttrDef { id: "SubGeographicalRegion.DCLines", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DCLine", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The DC lines in this sub-geographical region." },
6813 AttrDef { id: "SubGeographicalRegion.Lines", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Line", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "The lines within the sub-geographical region." },
6814 AttrDef { id: "SubGeographicalRegion.Region", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "GeographicalRegion", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "The geographical region which this sub-geographical region is within." },
6815 AttrDef { id: "SubGeographicalRegion.Substations", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Substation", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "The substations in this sub-geographical region." },
6816 ],
6817 },
6818 ClassDef {
6819 ns: "http://iec.ch/TC57/CIM100#",
6820 local: "SubLoadArea",
6821 qualified: "SubLoadArea",
6822 super_class: Some(93),
6823 concrete: true,
6824 origins: &["EQ"],
6825 comment: "The class is the second level in a hierarchical structure for grouping of loads for the purpose of load flow load scaling.",
6826 attrs: &[
6827 AttrDef { id: "SubLoadArea.LoadArea", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "LoadArea", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The LoadArea where the SubLoadArea belongs." },
6828 AttrDef { id: "SubLoadArea.LoadGroups", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "LoadGroup", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The Loadgroups in the SubLoadArea." },
6829 ],
6830 },
6831 ClassDef {
6832 ns: "http://iec.ch/TC57/CIM100#",
6833 local: "Substation",
6834 qualified: "Substation",
6835 super_class: Some(99),
6836 concrete: true,
6837 origins: &["EQ", "EQBD"],
6838 comment: "A collection of equipment for purposes other than generation or utilization, through which electric energy in bulk is passed for the purposes of switching or modifying its characteristics.",
6839 attrs: &[
6840 AttrDef { id: "Substation.DCConverterUnit", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DCConverterUnit", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The DC converter unit belonging of the substation." },
6841 AttrDef { id: "Substation.Region", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SubGeographicalRegion", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "The SubGeographicalRegion containing the substation." },
6842 AttrDef { id: "Substation.VoltageLevels", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "VoltageLevel", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "The voltage levels within this substation." },
6843 ],
6844 },
6845 ClassDef {
6846 ns: "http://iec.ch/TC57/CIM100#",
6847 local: "SurgeArrester",
6848 qualified: "SurgeArrester",
6849 super_class: Some(21),
6850 concrete: true,
6851 origins: &["EQ"],
6852 comment: "Shunt device, installed on the network, usually in the proximity of electrical equipment in order to protect the said equipment against transient voltage transients caused by lightning or switching activity.",
6853 attrs: &[],
6854 },
6855 ClassDef {
6856 ns: "http://iec.ch/TC57/CIM100#",
6857 local: "SvInjection",
6858 qualified: "SvInjection",
6859 super_class: None,
6860 concrete: true,
6861 origins: &["SV"],
6862 comment: "The SvInjection reports the calculated bus injection minus the sum of the terminal flows. The terminal flow is positive out from the bus (load sign convention) and bus injection has positive flow into the bus. SvInjection may have the remainder after state estimation or slack after power flow calculation.",
6863 attrs: &[
6864 AttrDef { id: "SvInjection.TopologicalNode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TopologicalNode", is_list: false, used: true, xsd: "", value_ns: "", origins: &["SV"], comment: "The topological node associated with the flow injection state variable." },
6865 AttrDef { id: "SvInjection.pInjection", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SV"], comment: "The active power mismatch between calculated injection and initial injection. Positive sign means injection into the TopologicalNode (bus)." },
6866 AttrDef { id: "SvInjection.qInjection", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SV"], comment: "The reactive power mismatch between calculated injection and initial injection. Positive sign means injection into the TopologicalNode (bus)." },
6867 ],
6868 },
6869 ClassDef {
6870 ns: "http://iec.ch/TC57/CIM100#",
6871 local: "SvPowerFlow",
6872 qualified: "SvPowerFlow",
6873 super_class: None,
6874 concrete: true,
6875 origins: &["SV"],
6876 comment: "State variable for power flow. Load convention is used for flow direction. This means flow out from the TopologicalNode into the equipment is positive.",
6877 attrs: &[
6878 AttrDef { id: "SvPowerFlow.Terminal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Terminal", is_list: false, used: true, xsd: "", value_ns: "", origins: &["SV"], comment: "The terminal associated with the power flow state variable." },
6879 AttrDef { id: "SvPowerFlow.p", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SV"], comment: "The active power flow. Load sign convention is used, i.e. positive sign means flow out from a TopologicalNode (bus) into the conducting equipment." },
6880 AttrDef { id: "SvPowerFlow.q", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SV"], comment: "The reactive power flow. Load sign convention is used, i.e. positive sign means flow out from a TopologicalNode (bus) into the conducting equipment." },
6881 ],
6882 },
6883 ClassDef {
6884 ns: "http://iec.ch/TC57/CIM100#",
6885 local: "SvShuntCompensatorSections",
6886 qualified: "SvShuntCompensatorSections",
6887 super_class: None,
6888 concrete: true,
6889 origins: &["SV"],
6890 comment: "State variable for the number of sections in service for a shunt compensator.",
6891 attrs: &[
6892 AttrDef { id: "SvShuntCompensatorSections.ShuntCompensator", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ShuntCompensator", is_list: false, used: true, xsd: "", value_ns: "", origins: &["SV"], comment: "The shunt compensator for which the state applies." },
6893 AttrDef { id: "SvShuntCompensatorSections.sections", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SV"], comment: "The number of sections in service as a continuous variable. The attribute shall be a positive value or zero. To get integer value scale with ShuntCompensator.bPerSection." },
6894 ],
6895 },
6896 ClassDef {
6897 ns: "http://iec.ch/TC57/CIM100#",
6898 local: "SvStatus",
6899 qualified: "SvStatus",
6900 super_class: None,
6901 concrete: true,
6902 origins: &["SV"],
6903 comment: "State variable for status.",
6904 attrs: &[
6905 AttrDef { id: "SvStatus.ConductingEquipment", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ConductingEquipment", is_list: false, used: true, xsd: "", value_ns: "", origins: &["SV"], comment: "The conducting equipment associated with the status state variable." },
6906 AttrDef { id: "SvStatus.inService", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["SV"], comment: "The in service status as a result of topology processing. It indicates if the equipment is considered as energized by the power flow. It reflects if the equipment is connected within a solvable island. It does not necessarily reflect whether or not the island was solved by the power flow." },
6907 ],
6908 },
6909 ClassDef {
6910 ns: "http://iec.ch/TC57/CIM100#",
6911 local: "SvSwitch",
6912 qualified: "SvSwitch",
6913 super_class: None,
6914 concrete: true,
6915 origins: &["SV"],
6916 comment: "State variable for switch.",
6917 attrs: &[
6918 AttrDef { id: "SvSwitch.Switch", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Switch", is_list: false, used: true, xsd: "", value_ns: "", origins: &["SV"], comment: "The switch associated with the switch state." },
6919 AttrDef { id: "SvSwitch.open", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["SV"], comment: "The attribute tells if the computed state of the switch is considered open." },
6920 ],
6921 },
6922 ClassDef {
6923 ns: "http://iec.ch/TC57/CIM100#",
6924 local: "SvTapStep",
6925 qualified: "SvTapStep",
6926 super_class: None,
6927 concrete: true,
6928 origins: &["SV"],
6929 comment: "State variable for transformer tap step.",
6930 attrs: &[
6931 AttrDef { id: "SvTapStep.TapChanger", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TapChanger", is_list: false, used: true, xsd: "", value_ns: "", origins: &["SV"], comment: "The tap changer associated with the tap step state." },
6932 AttrDef { id: "SvTapStep.position", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SV"], comment: "The floating point tap position. This is not the tap ratio, but rather the tap step position as defined by the related tap changer model and normally is constrained to be within the range of minimum and maximum tap positions." },
6933 ],
6934 },
6935 ClassDef {
6936 ns: "http://iec.ch/TC57/CIM100#",
6937 local: "SvVoltage",
6938 qualified: "SvVoltage",
6939 super_class: None,
6940 concrete: true,
6941 origins: &["SV"],
6942 comment: "State variable for voltage.",
6943 attrs: &[
6944 AttrDef { id: "SvVoltage.TopologicalNode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TopologicalNode", is_list: false, used: true, xsd: "", value_ns: "", origins: &["SV"], comment: "The topological node associated with the voltage state." },
6945 AttrDef { id: "SvVoltage.angle", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SV"], comment: "The voltage angle of the topological node complex voltage with respect to system reference." },
6946 AttrDef { id: "SvVoltage.v", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SV"], comment: "The voltage magnitude at the topological node. The attribute shall be a positive value." },
6947 ],
6948 },
6949 ClassDef {
6950 ns: "http://iec.ch/TC57/CIM100#",
6951 local: "Switch",
6952 qualified: "Switch",
6953 super_class: Some(37),
6954 concrete: true,
6955 origins: &["EQ", "SSH", "SV"],
6956 comment: "A generic device designed to close, or open, or both, one or more electric circuits. All switches are two terminal devices including grounding switches. The ACDCTerminal.connected at the two sides of the switch shall not be considered for assessing switch connectivity, i.e. only Switch.open, .normalOpen and .locked are relevant.",
6957 attrs: &[
6958 AttrDef { id: "Switch.SvSwitch", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SvSwitch", is_list: true, used: false, xsd: "", value_ns: "", origins: &["SV"], comment: "The switch state associated with the switch." },
6959 AttrDef { id: "Switch.SwitchSchedules", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SwitchSchedule", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "A Switch can be associated with SwitchSchedules." },
6960 AttrDef { id: "Switch.locked", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["SSH"], comment: "If true, the switch is locked. The resulting switch state is a combination of locked and Switch.open attributes as follows: locked=true and Switch.open=true. The resulting state is open and locked; locked=false and Switch.open=true. The resulting state is open; locked=false and Switch.open=false. The resulting state is closed." },
6961 AttrDef { id: "Switch.normalOpen", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["EQ"], comment: "The attribute is used in cases when no Measurement for the status value is present. If the Switch has a status measurement the Discrete.normalValue is expected to match with the Switch.normalOpen." },
6962 AttrDef { id: "Switch.open", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["SSH"], comment: "The attribute tells if the switch is considered open when used as input to topology processing." },
6963 AttrDef { id: "Switch.ratedCurrent", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "CurrentFlow", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The maximum continuous current carrying capacity in amps governed by the device material and construction. The attribute shall be a positive value." },
6964 AttrDef { id: "Switch.retained", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["EQ"], comment: "Branch is retained in the topological solution. The flow through retained switches will normally be calculated in power flow." },
6965 ],
6966 },
6967 ClassDef {
6968 ns: "http://iec.ch/TC57/CIM100#",
6969 local: "SwitchSchedule",
6970 qualified: "SwitchSchedule",
6971 super_class: Some(325),
6972 concrete: true,
6973 origins: &["EQ"],
6974 comment: "A schedule of switch positions. If RegularTimePoint.value1 is 0, the switch is open. If 1, the switch is closed.",
6975 attrs: &[
6976 AttrDef { id: "SwitchSchedule.Switch", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Switch", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "A SwitchSchedule is associated with a Switch." },
6977 ],
6978 },
6979 ClassDef {
6980 ns: "http://iec.ch/TC57/CIM100#",
6981 local: "SynchronousMachine",
6982 qualified: "SynchronousMachine",
6983 super_class: Some(320),
6984 concrete: true,
6985 origins: &["EQ", "DY", "SC", "SSH"],
6986 comment: "An electromechanical device that operates with shaft rotating synchronously with the network. It is a single machine operating either as a generator or synchronous condenser or pump.",
6987 attrs: &[
6988 AttrDef { id: "SynchronousMachine.InitialReactiveCapabilityCurve", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ReactiveCapabilityCurve", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The default reactive capability curve for use by a synchronous machine." },
6989 AttrDef { id: "SynchronousMachine.SynchronousMachineDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SynchronousMachineDynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Synchronous machine dynamics model used to describe dynamic behaviour of this synchronous machine." },
6990 AttrDef { id: "SynchronousMachine.earthing", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["SC"], comment: "Indicates whether or not the generator is earthed. Used for short circuit data exchange according to IEC 60909." },
6991 AttrDef { id: "SynchronousMachine.earthingStarPointR", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Generator star point earthing resistance (Re). Used for short circuit data exchange according to IEC 60909." },
6992 AttrDef { id: "SynchronousMachine.earthingStarPointX", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Generator star point earthing reactance (Xe). Used for short circuit data exchange according to IEC 60909." },
6993 AttrDef { id: "SynchronousMachine.ikk", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "CurrentFlow", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Steady-state short-circuit current (in A for the profile) of generator with compound excitation during 3-phase short circuit. - Ikk=0: Generator with no compound excitation. - Ikk<>0: Generator with compound excitation. Ikk is used to calculate the minimum steady-state short-circuit current for generators with compound excitation. (4.6.1.2 in IEC 60909-0:2001). Used only for single fed short circuit on a generator. (4.3.4.2. in IEC 60909-0:2001)." },
6994 AttrDef { id: "SynchronousMachine.maxQ", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Maximum reactive power limit. This is the maximum (nameplate) limit for the unit." },
6995 AttrDef { id: "SynchronousMachine.minQ", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Minimum reactive power limit for the unit." },
6996 AttrDef { id: "SynchronousMachine.mu", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Factor to calculate the breaking current (Section 4.5.2.1 in IEC 60909-0). Used only for single fed short circuit on a generator (Section 4.3.4.2. in IEC 60909-0)." },
6997 AttrDef { id: "SynchronousMachine.operatingMode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "SynchronousMachineOperatingMode", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["SSH"], comment: "Current mode of operation." },
6998 AttrDef { id: "SynchronousMachine.qPercent", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PerCent", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Part of the coordinated reactive control that comes from this machine. The attribute is used as a participation factor not necessarily summing up to 100% for the participating devices in the control." },
6999 AttrDef { id: "SynchronousMachine.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Equivalent resistance (RG) of generator. RG is considered for the calculation of all currents, except for the calculation of the peak current ip. Used for short circuit data exchange according to IEC 60909." },
7000 AttrDef { id: "SynchronousMachine.r0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence resistance of the synchronous machine." },
7001 AttrDef { id: "SynchronousMachine.r2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Negative sequence resistance." },
7002 AttrDef { id: "SynchronousMachine.referencePriority", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["SSH"], comment: "Priority of unit for use as powerflow voltage phase angle reference bus selection. 0 = don t care (default) 1 = highest priority. 2 is less than 1 and so on." },
7003 AttrDef { id: "SynchronousMachine.satDirectSubtransX", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Direct-axis subtransient reactance saturated, also known as Xd'sat." },
7004 AttrDef { id: "SynchronousMachine.satDirectSyncX", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Direct-axes saturated synchronous reactance (xdsat); reciprocal of short-circuit ration. Used for short circuit data exchange, only for single fed short circuit on a generator. (4.3.4.2. in IEC 60909-0:2001)." },
7005 AttrDef { id: "SynchronousMachine.satDirectTransX", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Saturated Direct-axis transient reactance. The attribute is primarily used for short circuit calculations according to ANSI." },
7006 AttrDef { id: "SynchronousMachine.shortCircuitRotorType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "ShortCircuitRotorKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["SC"], comment: "Type of rotor, used by short circuit applications, only for single fed short circuit according to IEC 60909." },
7007 AttrDef { id: "SynchronousMachine.type", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "SynchronousMachineKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "Modes that this synchronous machine can operate in." },
7008 AttrDef { id: "SynchronousMachine.voltageRegulationRange", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PerCent", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Range of generator voltage regulation (PG in IEC 60909-0) used for calculation of the impedance correction factor KG defined in IEC 60909-0. This attribute is used to describe the operating voltage of the generating unit." },
7009 AttrDef { id: "SynchronousMachine.x0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Zero sequence reactance of the synchronous machine." },
7010 AttrDef { id: "SynchronousMachine.x2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "Negative sequence reactance." },
7011 ],
7012 },
7013 ClassDef {
7014 ns: "http://iec.ch/TC57/CIM100#",
7015 local: "SynchronousMachineDetailed",
7016 qualified: "SynchronousMachineDetailed",
7017 super_class: Some(357),
7018 concrete: false,
7019 origins: &["DY"],
7020 comment: "All synchronous machine detailed types use a subset of the same data parameters and input/output variables. The several variations differ in the following ways: - the number of equivalent windings that are included; - the way in which saturation is incorporated into the model; - whether or not “subtransient saliency” (X''q not = X''d) is represented. It is not necessary for each simulation tool to have separate models for each of the model types. The same model can often be used for several types by alternative logic within the model. Also, differences in saturation representation might not result in significant model performance differences so model substitutions are often acceptable.",
7021 attrs: &[
7022 AttrDef { id: "SynchronousMachineDetailed.efdBaseRatio", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Ratio (exciter voltage/generator voltage) of Efd bases of exciter and generator models (> 0). Typical value = 1." },
7023 AttrDef { id: "SynchronousMachineDetailed.ifdBaseType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "IfdBaseKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Excitation base system mode. It should be equal to the value of WLMDV given by the user. WLMDV is the PU ratio between the field voltage and the excitation current: Efd = WLMDV x Ifd. Typical value = ifag." },
7024 AttrDef { id: "SynchronousMachineDetailed.saturationFactor120QAxis", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Quadrature-axis saturation factor at 120% of rated terminal voltage (S12q) (>= SynchonousMachineDetailed.saturationFactorQAxis). Typical value = 0,12." },
7025 AttrDef { id: "SynchronousMachineDetailed.saturationFactorQAxis", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Quadrature-axis saturation factor at rated terminal voltage (S1q) (>= 0). Typical value = 0,02." },
7026 ],
7027 },
7028 ClassDef {
7029 ns: "http://iec.ch/TC57/CIM100#",
7030 local: "SynchronousMachineDynamics",
7031 qualified: "SynchronousMachineDynamics",
7032 super_class: Some(321),
7033 concrete: false,
7034 origins: &["DY"],
7035 comment: "Synchronous machine whose behaviour is described by reference to a standard model expressed in one of the following forms: - simplified (or classical), where a group of generators or motors is not modelled in detail; - detailed, in equivalent circuit form; - detailed, in time constant reactance form; or - by definition of a user-defined model. It is a common practice to represent small generators by a negative load rather than by a dynamic generator model when performing dynamics simulations. In this case, a SynchronousMachine in the static model is not represented by anything in the dynamics model, instead it is treated as an ordinary load. Parameter details: Synchronous machine parameters such as Xl, Xd, Xp etc. are actually used as inductances in the models, but are commonly referred to as reactances since, at nominal frequency, the PU values are the same. However, some references use the symbol L instead of X.",
7036 attrs: &[
7037 AttrDef { id: "SynchronousMachineDynamics.CrossCompoundTurbineGovernorDyanmics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "CrossCompoundTurbineGovernorDynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "The cross-compound turbine governor with which this high-pressure synchronous machine is associated." },
7038 AttrDef { id: "SynchronousMachineDynamics.CrossCompoundTurbineGovernorDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "CrossCompoundTurbineGovernorDynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "The cross-compound turbine governor with which this low-pressure synchronous machine is associated." },
7039 AttrDef { id: "SynchronousMachineDynamics.ExcitationSystemDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ExcitationSystemDynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Excitation system model associated with this synchronous machine model." },
7040 AttrDef { id: "SynchronousMachineDynamics.GenICompensationForGenJ", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "GenICompensationForGenJ", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Compensation of voltage compensator's generator for current flow out of this generator." },
7041 AttrDef { id: "SynchronousMachineDynamics.MechanicalLoadDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "MechanicalLoadDynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Mechanical load model associated with this synchronous machine model." },
7042 AttrDef { id: "SynchronousMachineDynamics.SynchronousMachine", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SynchronousMachine", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Synchronous machine to which synchronous machine dynamics model applies." },
7043 AttrDef { id: "SynchronousMachineDynamics.TurbineGovernorDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TurbineGovernorDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Turbine-governor model associated with this synchronous machine model. Multiplicity of greater than one is intended to support hydro units that have multiple turbines on one generator." },
7044 ],
7045 },
7046 ClassDef {
7047 ns: "http://iec.ch/TC57/CIM100#",
7048 local: "SynchronousMachineEquivalentCircuit",
7049 qualified: "SynchronousMachineEquivalentCircuit",
7050 super_class: Some(356),
7051 concrete: true,
7052 origins: &["DY"],
7053 comment: "The electrical equations for all variations of the synchronous models are based on the SynchronousEquivalentCircuit diagram for the direct- and quadrature- axes. Equations for conversion between equivalent circuit and time constant reactance forms: Xd = Xad + Xl X’d = Xl + Xad x Xfd / (Xad + Xfd) X”d = Xl + Xad x Xfd x X1d / (Xad x Xfd + Xad x X1d + Xfd x X1d) Xq = Xaq + Xl X’q = Xl + Xaq x X1q / (Xaq + X1q) X”q = Xl + Xaq x X1q x X2q / (Xaq x X1q + Xaq x X2q + X1q x X2q) T’do = (Xad + Xfd) / (omega0 x Rfd) T”do = (Xad x Xfd + Xad x X1d + Xfd x X1d) / (omega0 x R1d x (Xad + Xfd) T’qo = (Xaq + X1q) / (omega0 x R1q) T”qo = (Xaq x X1q + Xaq x X2q + X1q x X2q) / (omega0 x R2q x (Xaq + X1q) Same equations using CIM attributes from SynchronousMachineTimeConstantReactance class on left of '=' and SynchronousMachineEquivalentCircuit class on right (except as noted): xDirectSync = xad + RotatingMachineDynamics.statorLeakageReactance xDirectTrans = RotatingMachineDynamics.statorLeakageReactance + xad x xfd / (xad + xfd) xDirectSubtrans = RotatingMachineDynamics.statorLeakageReactance + xad x xfd x x1d / (xad x xfd + xad x x1d + xfd x x1d) xQuadSync = xaq + RotatingMachineDynamics.statorLeakageReactance xQuadTrans = RotatingMachineDynamics.statorLeakageReactance + xaq x x1q / (xaq+ x1q) xQuadSubtrans = RotatingMachineDynamics.statorLeakageReactance + xaq x x1q x x2q / (xaq x x1q + xaq x x2q + x1q x x2q) tpdo = (xad + xfd) / (2 x pi x nominal frequency x rfd) tppdo = (xad x xfd + xad x x1d + xfd x x1d) / (2 x pi x nominal frequency x r1d x (xad + xfd) tpqo = (xaq + x1q) / (2 x pi x nominal frequency x r1q) tppqo = (xaq x x1q + xaq x x2q + x1q x x2q) / (2 x pi x nominal frequency x r2q x (xaq + x1q) These are only valid for a simplified model where 'Canay' reactance is zero.",
7054 attrs: &[
7055 AttrDef { id: "SynchronousMachineEquivalentCircuit.r1d", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Direct-axis damper 1 winding resistance." },
7056 AttrDef { id: "SynchronousMachineEquivalentCircuit.r1q", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Quadrature-axis damper 1 winding resistance." },
7057 AttrDef { id: "SynchronousMachineEquivalentCircuit.r2q", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Quadrature-axis damper 2 winding resistance." },
7058 AttrDef { id: "SynchronousMachineEquivalentCircuit.rfd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field winding resistance." },
7059 AttrDef { id: "SynchronousMachineEquivalentCircuit.x1d", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Direct-axis damper 1 winding leakage reactance." },
7060 AttrDef { id: "SynchronousMachineEquivalentCircuit.x1q", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Quadrature-axis damper 1 winding leakage reactance." },
7061 AttrDef { id: "SynchronousMachineEquivalentCircuit.x2q", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Quadrature-axis damper 2 winding leakage reactance." },
7062 AttrDef { id: "SynchronousMachineEquivalentCircuit.xad", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Direct-axis mutual reactance." },
7063 AttrDef { id: "SynchronousMachineEquivalentCircuit.xaq", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Quadrature-axis mutual reactance." },
7064 AttrDef { id: "SynchronousMachineEquivalentCircuit.xf1d", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Differential mutual (“Canay”) reactance." },
7065 AttrDef { id: "SynchronousMachineEquivalentCircuit.xfd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Field winding leakage reactance." },
7066 ],
7067 },
7068 ClassDef {
7069 ns: "http://iec.ch/TC57/CIM100#",
7070 local: "SynchronousMachineSimplified",
7071 qualified: "SynchronousMachineSimplified",
7072 super_class: Some(357),
7073 concrete: true,
7074 origins: &["DY"],
7075 comment: "The simplified model represents a synchronous generator as a constant internal voltage behind an impedance (Rs + jXp) as shown in the Simplified diagram. Since internal voltage is held constant, there is no Efd input and any excitation system model will be ignored. There is also no Ifd output. This model should not be used for representing a real generator except, perhaps, small generators whose response is insignificant. The parameters used for the simplified model include: - RotatingMachineDynamics.damping (D); - RotatingMachineDynamics.inertia (H); - RotatingMachineDynamics.statorLeakageReactance (used to exchange jXp for SynchronousMachineSimplified); - RotatingMachineDynamics.statorResistance (Rs).",
7076 attrs: &[],
7077 },
7078 ClassDef {
7079 ns: "http://iec.ch/TC57/CIM100#",
7080 local: "SynchronousMachineTimeConstantReactance",
7081 qualified: "SynchronousMachineTimeConstantReactance",
7082 super_class: Some(356),
7083 concrete: true,
7084 origins: &["DY"],
7085 comment: "Synchronous machine detailed modelling types are defined by the combination of the attributes SynchronousMachineTimeConstantReactance.modelType and SynchronousMachineTimeConstantReactance.rotorType. Parameter details: The “p” in the time-related attribute names is a substitution for a “prime” in the usual parameter notation, e.g. tpdo refers to T'do. The parameters used for models expressed in time constant reactance form include: - RotatingMachine.ratedS (MVAbase); - RotatingMachineDynamics.damping (D); - RotatingMachineDynamics.inertia (H); - RotatingMachineDynamics.saturationFactor (S1); - RotatingMachineDynamics.saturationFactor120 (S12); - RotatingMachineDynamics.statorLeakageReactance (Xl); - RotatingMachineDynamics.statorResistance (Rs); - SynchronousMachineTimeConstantReactance.ks (Ks); - SynchronousMachineDetailed.saturationFactorQAxis (S1q); - SynchronousMachineDetailed.saturationFactor120QAxis (S12q); - SynchronousMachineDetailed.efdBaseRatio; - SynchronousMachineDetailed.ifdBaseType; - .xDirectSync (Xd); - .xDirectTrans (X'd); - .xDirectSubtrans (X''d); - .xQuadSync (Xq); - .xQuadTrans (X'q); - .xQuadSubtrans (X''q); - .tpdo (T'do); - .tppdo (T''do); - .tpqo (T'qo); - .tppqo (T''qo); - .tc.",
7086 attrs: &[
7087 AttrDef { id: "SynchronousMachineTimeConstantReactance.ks", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Saturation loading correction factor (Ks) (>= 0). Used only by type J model. Typical value = 0." },
7088 AttrDef { id: "SynchronousMachineTimeConstantReactance.modelType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "SynchronousMachineModelKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Type of synchronous machine model used in dynamic simulation applications." },
7089 AttrDef { id: "SynchronousMachineTimeConstantReactance.rotorType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "RotorKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Type of rotor on physical machine." },
7090 AttrDef { id: "SynchronousMachineTimeConstantReactance.tc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Damping time constant for “Canay” reactance (>= 0). Typical value = 0." },
7091 AttrDef { id: "SynchronousMachineTimeConstantReactance.tpdo", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Direct-axis transient rotor time constant (T'do) (> SynchronousMachineTimeConstantReactance.tppdo). Typical value = 5." },
7092 AttrDef { id: "SynchronousMachineTimeConstantReactance.tppdo", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Direct-axis subtransient rotor time constant (T''do) (> 0). Typical value = 0,03." },
7093 AttrDef { id: "SynchronousMachineTimeConstantReactance.tppqo", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Quadrature-axis subtransient rotor time constant (T''qo) (> 0). Typical value = 0,03." },
7094 AttrDef { id: "SynchronousMachineTimeConstantReactance.tpqo", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Quadrature-axis transient rotor time constant (T'qo) (> SynchronousMachineTimeConstantReactance.tppqo). Typical value = 0,5." },
7095 AttrDef { id: "SynchronousMachineTimeConstantReactance.xDirectSubtrans", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Direct-axis subtransient reactance (unsaturated) (X''d) (> RotatingMachineDynamics.statorLeakageReactance). Typical value = 0,2." },
7096 AttrDef { id: "SynchronousMachineTimeConstantReactance.xDirectSync", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Direct-axis synchronous reactance (Xd) (>= SynchronousMachineTimeConstantReactance.xDirectTrans). The quotient of a sustained value of that AC component of armature voltage that is produced by the total direct-axis flux due to direct-axis armature current and the value of the AC component of this current, the machine running at rated speed. Typical value = 1,8." },
7097 AttrDef { id: "SynchronousMachineTimeConstantReactance.xDirectTrans", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Direct-axis transient reactance (unsaturated) (X'd) (>= SynchronousMachineTimeConstantReactance.xDirectSubtrans). Typical value = 0,5." },
7098 AttrDef { id: "SynchronousMachineTimeConstantReactance.xQuadSubtrans", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Quadrature-axis subtransient reactance (X''q) (> RotatingMachineDynamics.statorLeakageReactance). Typical value = 0,2." },
7099 AttrDef { id: "SynchronousMachineTimeConstantReactance.xQuadSync", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Quadrature-axis synchronous reactance (Xq) (>= SynchronousMachineTimeConstantReactance.xQuadTrans). The ratio of the component of reactive armature voltage, due to the quadrature-axis component of armature current, to this component of current, under steady state conditions and at rated frequency. Typical value = 1,6." },
7100 AttrDef { id: "SynchronousMachineTimeConstantReactance.xQuadTrans", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Quadrature-axis transient reactance (X'q) (>= SynchronousMachineTimeConstantReactance.xQuadSubtrans). Typical value = 0,3." },
7101 ],
7102 },
7103 ClassDef {
7104 ns: "http://iec.ch/TC57/CIM100#",
7105 local: "SynchronousMachineUserDefined",
7106 qualified: "SynchronousMachineUserDefined",
7107 super_class: Some(357),
7108 concrete: true,
7109 origins: &["DY"],
7110 comment: "Synchronous machine whose dynamic behaviour is described by a user-defined model.",
7111 attrs: &[
7112 AttrDef { id: "SynchronousMachineUserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
7113 AttrDef { id: "SynchronousMachineUserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
7114 ],
7115 },
7116 ClassDef {
7117 ns: "http://iec.ch/TC57/CIM100#",
7118 local: "TapChanger",
7119 qualified: "TapChanger",
7120 super_class: Some(282),
7121 concrete: false,
7122 origins: &["EQ", "SSH", "SV"],
7123 comment: "Mechanism for changing transformer winding tap positions.",
7124 attrs: &[
7125 AttrDef { id: "TapChanger.SvTapStep", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SvTapStep", is_list: false, used: false, xsd: "", value_ns: "", origins: &["SV"], comment: "The tap step state associated with the tap changer." },
7126 AttrDef { id: "TapChanger.TapChangerControl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TapChangerControl", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The regulating control scheme in which this tap changer participates." },
7127 AttrDef { id: "TapChanger.TapSchedules", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TapSchedule", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "A TapChanger can have TapSchedules." },
7128 AttrDef { id: "TapChanger.controlEnabled", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["SSH"], comment: "Specifies the regulation status of the equipment. True is regulating, false is not regulating." },
7129 AttrDef { id: "TapChanger.highStep", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["EQ"], comment: "Highest possible tap step position, advance from neutral. The attribute shall be greater than lowStep." },
7130 AttrDef { id: "TapChanger.lowStep", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["EQ"], comment: "Lowest possible tap step position, retard from neutral." },
7131 AttrDef { id: "TapChanger.ltcFlag", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["EQ"], comment: "Specifies whether or not a TapChanger has load tap changing capabilities." },
7132 AttrDef { id: "TapChanger.neutralStep", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["EQ"], comment: "The neutral tap step position for this winding. The attribute shall be equal to or greater than lowStep and equal or less than highStep. It is the step position where the voltage is neutralU when the other terminals of the transformer are at the ratedU. If there are other tap changers on the transformer those taps are kept constant at their neutralStep." },
7133 AttrDef { id: "TapChanger.neutralU", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "Voltage at which the winding operates at the neutral tap setting. It is the voltage at the terminal of the PowerTransformerEnd associated with the tap changer when all tap changers on the transformer are at their neutralStep position. Normally neutralU of the tap changer is the same as ratedU of the PowerTransformerEnd, but it can differ in special cases such as when the tapping mechanism is separate from the winding more common on lower voltage transformers. This attribute is not relevant for PhaseTapChangerAsymmetrical, PhaseTapChangerSymmetrical and PhaseTapChangerLinear." },
7134 AttrDef { id: "TapChanger.normalStep", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["EQ"], comment: "The tap step position used in 'normal' network operation for this winding. For a 'Fixed' tap changer indicates the current physical tap setting. The attribute shall be equal to or greater than lowStep and equal to or less than highStep." },
7135 AttrDef { id: "TapChanger.step", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Tap changer position. Starting step for a steady state solution. Non integer values are allowed to support continuous tap variables. The reasons for continuous value are to support study cases where no discrete tap changer has yet been designed, a solution where a narrow voltage band forces the tap step to oscillate or to accommodate for a continuous solution as input. The attribute shall be equal to or greater than lowStep and equal to or less than highStep." },
7136 ],
7137 },
7138 ClassDef {
7139 ns: "http://iec.ch/TC57/CIM100#",
7140 local: "TapChangerControl",
7141 qualified: "TapChangerControl",
7142 super_class: Some(316),
7143 concrete: true,
7144 origins: &["EQ", "SSH"],
7145 comment: "Describes behaviour specific to tap changers, e.g. how the voltage at the end of a line varies with the load level and compensation of the voltage drop by tap adjustment.",
7146 attrs: &[
7147 AttrDef { id: "TapChangerControl.TapChanger", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TapChanger", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The tap changers that participates in this regulating tap control scheme." },
7148 ],
7149 },
7150 ClassDef {
7151 ns: "http://iec.ch/TC57/CIM100#",
7152 local: "TapChangerTablePoint",
7153 qualified: "TapChangerTablePoint",
7154 super_class: None,
7155 concrete: false,
7156 origins: &["EQ"],
7157 comment: "Describes each tap step in the tabular curve.",
7158 attrs: &[
7159 AttrDef { id: "TapChangerTablePoint.b", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PerCent", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The magnetizing branch susceptance deviation as a percentage of nominal value. The actual susceptance is calculated as follows: calculated magnetizing susceptance = b(nominal) * (1 + b(from this class)/100). The b(nominal) is defined as the static magnetizing susceptance on the associated power transformer end or ends. This model assumes the star impedance (pi model) form." },
7160 AttrDef { id: "TapChangerTablePoint.g", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PerCent", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The magnetizing branch conductance deviation as a percentage of nominal value. The actual conductance is calculated as follows: calculated magnetizing conductance = g(nominal) * (1 + g(from this class)/100). The g(nominal) is defined as the static magnetizing conductance on the associated power transformer end or ends. This model assumes the star impedance (pi model) form." },
7161 AttrDef { id: "TapChangerTablePoint.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PerCent", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The resistance deviation as a percentage of nominal value. The actual reactance is calculated as follows: calculated resistance = r(nominal) * (1 + r(from this class)/100). The r(nominal) is defined as the static resistance on the associated power transformer end or ends. This model assumes the star impedance (pi model) form." },
7162 AttrDef { id: "TapChangerTablePoint.ratio", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The voltage at the tap step divided by rated voltage of the transformer end having the tap changer. Hence this is a value close to one. For example, if the ratio at step 1 is 1.01, and the rated voltage of the transformer end is 110kV, then the voltage obtained by setting the tap changer to step 1 to is 111.1kV." },
7163 AttrDef { id: "TapChangerTablePoint.step", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["EQ"], comment: "The tap step." },
7164 AttrDef { id: "TapChangerTablePoint.x", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PerCent", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The series reactance deviation as a percentage of nominal value. The actual reactance is calculated as follows: calculated reactance = x(nominal) * (1 + x(from this class)/100). The x(nominal) is defined as the static series reactance on the associated power transformer end or ends. This model assumes the star impedance (pi model) form." },
7165 ],
7166 },
7167 ClassDef {
7168 ns: "http://iec.ch/TC57/CIM100#",
7169 local: "TapSchedule",
7170 qualified: "TapSchedule",
7171 super_class: Some(325),
7172 concrete: true,
7173 origins: &["EQ"],
7174 comment: "A pre-established pattern over time for a tap step.",
7175 attrs: &[
7176 AttrDef { id: "TapSchedule.TapChanger", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TapChanger", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "A TapSchedule is associated with a TapChanger." },
7177 ],
7178 },
7179 ClassDef {
7180 ns: "http://iec.ch/TC57/CIM100#",
7181 local: "Terminal",
7182 qualified: "Terminal",
7183 super_class: Some(2),
7184 concrete: true,
7185 origins: &["EQ", "DY", "EQBD", "OP", "SC", "SSH", "SV", "TP"],
7186 comment: "An AC electrical connection point to a piece of conducting equipment. Terminals are connected at physical connection points called connectivity nodes.",
7187 attrs: &[
7188 AttrDef { id: "Terminal.AuxiliaryEquipment", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "AuxiliaryEquipment", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The auxiliary equipment connected to the terminal." },
7189 AttrDef { id: "Terminal.ConductingEquipment", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ConductingEquipment", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ", "DY", "EQBD"], comment: "The conducting equipment of the terminal. Conducting equipment have terminals that may be connected to other conducting equipment terminals via connectivity nodes or topological nodes." },
7190 AttrDef { id: "Terminal.ConnectivityNode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ConnectivityNode", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "The connectivity node to which this terminal connects with zero impedance." },
7191 AttrDef { id: "Terminal.ConverterDCSides", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ACDCConverter", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "All converters' DC sides linked to this point of common coupling terminal." },
7192 AttrDef { id: "Terminal.HasFirstMutualCoupling", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "MutualCoupling", is_list: true, used: false, xsd: "", value_ns: "", origins: &["SC"], comment: "Mutual couplings associated with the branch as the first branch." },
7193 AttrDef { id: "Terminal.HasSecondMutualCoupling", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "MutualCoupling", is_list: true, used: false, xsd: "", value_ns: "", origins: &["SC"], comment: "Mutual couplings with the branch associated as the first branch." },
7194 AttrDef { id: "Terminal.RegulatingControl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RegulatingControl", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The controls regulating this terminal." },
7195 AttrDef { id: "Terminal.RemoteInputSignal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RemoteInputSignal", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Input signal coming from this terminal." },
7196 AttrDef { id: "Terminal.SvPowerFlow", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SvPowerFlow", is_list: false, used: false, xsd: "", value_ns: "", origins: &["SV"], comment: "The power flow state variable associated with the terminal." },
7197 AttrDef { id: "Terminal.TieFlow", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TieFlow", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "The control area tie flows to which this terminal associates." },
7198 AttrDef { id: "Terminal.TopologicalNode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TopologicalNode", is_list: false, used: true, xsd: "", value_ns: "", origins: &["TP"], comment: "The topological node associated with the terminal. This can be used as an alternative to the connectivity node path to topological node, thus making it unnecessary to model connectivity nodes in some cases. Note that the if connectivity nodes are in the model, this association would probably not be used as an input specification." },
7199 AttrDef { id: "Terminal.TransformerEnd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TransformerEnd", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "All transformer ends connected at this terminal." },
7200 AttrDef { id: "Terminal.phases", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "PhaseCode", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "Represents the normal network phasing condition. If the attribute is missing, three phases (ABC) shall be assumed, except for terminals of grounding classes (specializations of EarthFaultCompensator, GroundDisconnector, and Ground) which will be assumed to be N. Therefore, phase code ABCN is explicitly declared when needed, e.g. for star point grounding equipment. The phase code on terminals connecting same ConnectivityNode or same TopologicalNode as well as for equipment between two terminals shall be consistent." },
7201 ],
7202 },
7203 ClassDef {
7204 ns: "http://iec.ch/TC57/CIM100#",
7205 local: "TextDiagramObject",
7206 qualified: "TextDiagramObject",
7207 super_class: Some(76),
7208 concrete: true,
7209 origins: &["DL"],
7210 comment: "A diagram object for placing free-text or text derived from an associated domain object.",
7211 attrs: &[
7212 AttrDef { id: "TextDiagramObject.text", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["DL"], comment: "The text that is displayed by this text diagram object." },
7213 ],
7214 },
7215 ClassDef {
7216 ns: "http://iec.ch/TC57/CIM100#",
7217 local: "ThermalGeneratingUnit",
7218 qualified: "ThermalGeneratingUnit",
7219 super_class: Some(169),
7220 concrete: true,
7221 origins: &["EQ", "SSH"],
7222 comment: "A generating unit whose prime mover could be a steam turbine, combustion turbine, or diesel engine.",
7223 attrs: &[
7224 AttrDef { id: "ThermalGeneratingUnit.CAESPlant", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "CAESPlant", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "A thermal generating unit may be a member of a compressed air energy storage plant." },
7225 AttrDef { id: "ThermalGeneratingUnit.CogenerationPlant", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "CogenerationPlant", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "A thermal generating unit may be a member of a cogeneration plant." },
7226 AttrDef { id: "ThermalGeneratingUnit.CombinedCyclePlant", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "CombinedCyclePlant", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "A thermal generating unit may be a member of a combined cycle plant." },
7227 AttrDef { id: "ThermalGeneratingUnit.FossilFuels", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "FossilFuel", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "A thermal generating unit may have one or more fossil fuels." },
7228 ],
7229 },
7230 ClassDef {
7231 ns: "http://iec.ch/TC57/CIM100#",
7232 local: "TieFlow",
7233 qualified: "TieFlow",
7234 super_class: Some(213),
7235 concrete: true,
7236 origins: &["EQ"],
7237 comment: "Defines the structure (in terms of location and direction) of the net interchange constraint for a control area. This constraint may be used by either AGC or power flow.",
7238 attrs: &[
7239 AttrDef { id: "TieFlow.ControlArea", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ControlArea", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The control area of the tie flows." },
7240 AttrDef { id: "TieFlow.Terminal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Terminal", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "The terminal to which this tie flow belongs." },
7241 AttrDef { id: "TieFlow.positiveFlowIn", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["EQ"], comment: "Specifies the sign of the tie flow associated with a control area. True if positive flow into the terminal (load convention) is also positive flow into the control area. See the description of ControlArea for further explanation of how TieFlow.positiveFlowIn is used." },
7242 ],
7243 },
7244 ClassDef {
7245 ns: "http://iec.ch/TC57/CIM100#",
7246 local: "TopologicalIsland",
7247 qualified: "TopologicalIsland",
7248 super_class: Some(213),
7249 concrete: true,
7250 origins: &["SV"],
7251 comment: "An electrically connected subset of the network. Topological islands can change as the current network state changes, e.g. due to: - disconnect switches or breakers changing state in a SCADA/EMS. - manual creation, change or deletion of topological nodes in a planning tool. Only energised TopologicalNode-s shall be part of the topological island.",
7252 attrs: &[
7253 AttrDef { id: "TopologicalIsland.AngleRefTopologicalNode", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TopologicalNode", is_list: false, used: true, xsd: "", value_ns: "", origins: &["SV"], comment: "The angle reference for the island. Normally there is one TopologicalNode that is selected as the angle reference for each island. Other reference schemes exist, so the association is typically optional." },
7254 AttrDef { id: "TopologicalIsland.TopologicalNodes", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TopologicalNode", is_list: true, used: true, xsd: "", value_ns: "", origins: &["SV"], comment: "A topological node belongs to a topological island." },
7255 ],
7256 },
7257 ClassDef {
7258 ns: "http://iec.ch/TC57/CIM100#",
7259 local: "TopologicalNode",
7260 qualified: "TopologicalNode",
7261 super_class: Some(213),
7262 concrete: true,
7263 origins: &["TP", "SV"],
7264 comment: "For a detailed substation model a topological node is a set of connectivity nodes that, in the current network state, are connected together through any type of closed switches, including jumpers. Topological nodes change as the current network state changes (i.e., switches, breakers, etc. change state). For a planning model, switch statuses are not used to form topological nodes. Instead they are manually created or deleted in a model builder tool. Topological nodes maintained this way are also called 'busses'.",
7265 attrs: &[
7266 AttrDef { id: "TopologicalNode.AngleRefTopologicalIsland", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TopologicalIsland", is_list: false, used: false, xsd: "", value_ns: "", origins: &["SV"], comment: "The island for which the node is an angle reference. Normally there is one angle reference node for each island." },
7267 AttrDef { id: "TopologicalNode.BaseVoltage", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "BaseVoltage", is_list: false, used: true, xsd: "", value_ns: "", origins: &["TP"], comment: "The base voltage of the topological node." },
7268 AttrDef { id: "TopologicalNode.ConnectivityNodeContainer", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ConnectivityNodeContainer", is_list: false, used: true, xsd: "", value_ns: "", origins: &["TP"], comment: "The connectivity node container to which the topological node belongs." },
7269 AttrDef { id: "TopologicalNode.ConnectivityNodes", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ConnectivityNode", is_list: true, used: false, xsd: "", value_ns: "", origins: &["TP"], comment: "The connectivity nodes combine together to form this topological node. May depend on the current state of switches in the network." },
7270 AttrDef { id: "TopologicalNode.ReportingGroup", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ReportingGroup", is_list: false, used: true, xsd: "", value_ns: "", origins: &["TP"], comment: "The reporting group to which the topological node belongs." },
7271 AttrDef { id: "TopologicalNode.SvInjection", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SvInjection", is_list: false, used: false, xsd: "", value_ns: "", origins: &["SV"], comment: "The injection flows state variables associated with the topological node." },
7272 AttrDef { id: "TopologicalNode.SvVoltage", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SvVoltage", is_list: false, used: false, xsd: "", value_ns: "", origins: &["SV"], comment: "The state voltage associated with the topological node." },
7273 AttrDef { id: "TopologicalNode.Terminal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Terminal", is_list: true, used: false, xsd: "", value_ns: "", origins: &["TP"], comment: "The terminals associated with the topological node. This can be used as an alternative to the connectivity node path to terminal, thus making it unnecessary to model connectivity nodes in some cases. Note that if connectivity nodes are in the model, this association would probably not be used as an input specification." },
7274 AttrDef { id: "TopologicalNode.TopologicalIsland", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TopologicalIsland", is_list: false, used: false, xsd: "", value_ns: "", origins: &["SV"], comment: "A topological node belongs to a topological island." },
7275 ],
7276 },
7277 ClassDef {
7278 ns: "http://iec.ch/TC57/CIM100#",
7279 local: "TownDetail",
7280 qualified: "TownDetail",
7281 super_class: None,
7282 concrete: false,
7283 origins: &["GL"],
7284 comment: "Town details, in the context of address.",
7285 attrs: &[
7286 AttrDef { id: "TownDetail.code", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "Town code." },
7287 AttrDef { id: "TownDetail.country", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "Name of the country." },
7288 AttrDef { id: "TownDetail.name", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "Town name." },
7289 AttrDef { id: "TownDetail.section", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "Town section. For example, it is common for there to be 36 sections per township." },
7290 AttrDef { id: "TownDetail.stateOrProvince", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "String", is_list: false, used: true, xsd: "string", value_ns: "", origins: &["GL"], comment: "Name of the state or province." },
7291 ],
7292 },
7293 ClassDef {
7294 ns: "http://iec.ch/TC57/CIM100#",
7295 local: "TransformerEnd",
7296 qualified: "TransformerEnd",
7297 super_class: Some(213),
7298 concrete: false,
7299 origins: &["EQ", "SC"],
7300 comment: "A conducting connection point of a power transformer. It corresponds to a physical transformer winding terminal. In earlier CIM versions, the TransformerWinding class served a similar purpose, but this class is more flexible because it associates to terminal but is not a specialization of ConductingEquipment.",
7301 attrs: &[
7302 AttrDef { id: "TransformerEnd.BaseVoltage", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "BaseVoltage", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "Base voltage of the transformer end. This is essential for PU calculation." },
7303 AttrDef { id: "TransformerEnd.PhaseTapChanger", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PhaseTapChanger", is_list: false, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "Phase tap changer associated with this transformer end." },
7304 AttrDef { id: "TransformerEnd.RatioTapChanger", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RatioTapChanger", is_list: false, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "Ratio tap changer associated with this transformer end." },
7305 AttrDef { id: "TransformerEnd.Terminal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Terminal", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "Terminal of the power transformer to which this transformer end belongs." },
7306 AttrDef { id: "TransformerEnd.endNumber", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["EQ"], comment: "Number for this transformer end, corresponding to the end's order in the power transformer vector group or phase angle clock number. Highest voltage winding should be 1. Each end within a power transformer should have a unique subsequent end number. Note the transformer end number need not match the terminal sequence number." },
7307 AttrDef { id: "TransformerEnd.grounded", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["SC"], comment: "(for Yn and Zn connections) True if the neutral is solidly grounded." },
7308 AttrDef { id: "TransformerEnd.rground", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "(for Yn and Zn connections) Resistance part of neutral impedance where 'grounded' is true." },
7309 AttrDef { id: "TransformerEnd.xground", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Reactance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SC"], comment: "(for Yn and Zn connections) Reactive part of neutral impedance where 'grounded' is true." },
7310 ],
7311 },
7312 ClassDef {
7313 ns: "http://iec.ch/TC57/CIM100#",
7314 local: "TurbLCFB1",
7315 qualified: "TurbLCFB1",
7316 super_class: Some(377),
7317 concrete: true,
7318 origins: &["DY"],
7319 comment: "Turbine load controller model developed by WECC. This model represents a supervisory turbine load controller that acts to maintain turbine power at a set value by continuous adjustment of the turbine governor speed-load reference. This model is intended to represent slow reset 'outer loop' controllers managing the action of the turbine governor.",
7320 attrs: &[
7321 AttrDef { id: "TurbLCFB1.db", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Controller deadband (db). Typical value = 0." },
7322 AttrDef { id: "TurbLCFB1.emax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum control error (Emax) (see parameter detail 4). Typical value = 0,02." },
7323 AttrDef { id: "TurbLCFB1.fb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Frequency bias gain (Fb). Typical value = 0." },
7324 AttrDef { id: "TurbLCFB1.fbf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Frequency bias flag (Fbf). true = enable frequency bias false = disable frequency bias. Typical value = false." },
7325 AttrDef { id: "TurbLCFB1.irmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum turbine speed/load reference bias (Irmax) (see parameter detail 3). Typical value = 0." },
7326 AttrDef { id: "TurbLCFB1.ki", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Integral gain (Ki). Typical value = 0." },
7327 AttrDef { id: "TurbLCFB1.kp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Proportional gain (Kp). Typical value = 0." },
7328 AttrDef { id: "TurbLCFB1.mwbase", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Base for power values (MWbase) (> 0). Unit = MW." },
7329 AttrDef { id: "TurbLCFB1.pbf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Power controller flag (Pbf). true = enable load controller false = disable load controller. Typical value = false." },
7330 AttrDef { id: "TurbLCFB1.pmwset", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ActivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power controller setpoint (Pmwset) (see parameter detail 1). Unit = MW. Typical value = 0." },
7331 AttrDef { id: "TurbLCFB1.speedReferenceGovernor", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Type of turbine governor reference (Type). true = speed reference governor false = load reference governor. Typical value = true." },
7332 AttrDef { id: "TurbLCFB1.tpelec", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power transducer time constant (Tpelec) (>= 0). Typical value = 0." },
7333 ],
7334 },
7335 ClassDef {
7336 ns: "http://iec.ch/TC57/CIM100#",
7337 local: "TurbineGovernorDynamics",
7338 qualified: "TurbineGovernorDynamics",
7339 super_class: Some(91),
7340 concrete: false,
7341 origins: &["DY"],
7342 comment: "Turbine-governor function block whose behaviour is described by reference to a standard model or by definition of a user-defined model.",
7343 attrs: &[
7344 AttrDef { id: "TurbineGovernorDynamics.AsynchronousMachineDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "AsynchronousMachineDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Asynchronous machine model with which this turbine-governor model is associated. TurbineGovernorDynamics shall have either an association to SynchronousMachineDynamics or to AsynchronousMachineDynamics." },
7345 AttrDef { id: "TurbineGovernorDynamics.SynchronousMachineDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "SynchronousMachineDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Synchronous machine model with which this turbine-governor model is associated. TurbineGovernorDynamics shall have either an association to SynchronousMachineDynamics or to AsynchronousMachineDynamics." },
7346 AttrDef { id: "TurbineGovernorDynamics.TurbineLoadControllerDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TurbineLoadControllerDynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Turbine load controller providing input to this turbine-governor." },
7347 ],
7348 },
7349 ClassDef {
7350 ns: "http://iec.ch/TC57/CIM100#",
7351 local: "TurbineGovernorUserDefined",
7352 qualified: "TurbineGovernorUserDefined",
7353 super_class: Some(375),
7354 concrete: true,
7355 origins: &["DY"],
7356 comment: "Turbine-governor function block whose dynamic behaviour is described by a user-defined model.",
7357 attrs: &[
7358 AttrDef { id: "TurbineGovernorUserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
7359 AttrDef { id: "TurbineGovernorUserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
7360 ],
7361 },
7362 ClassDef {
7363 ns: "http://iec.ch/TC57/CIM100#",
7364 local: "TurbineLoadControllerDynamics",
7365 qualified: "TurbineLoadControllerDynamics",
7366 super_class: Some(91),
7367 concrete: false,
7368 origins: &["DY"],
7369 comment: "Turbine load controller function block whose behaviour is described by reference to a standard model or by definition of a user-defined model.",
7370 attrs: &[
7371 AttrDef { id: "TurbineLoadControllerDynamics.TurbineGovernorDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "TurbineGovernorDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Turbine-governor controlled by this turbine load controller." },
7372 ],
7373 },
7374 ClassDef {
7375 ns: "http://iec.ch/TC57/CIM100#",
7376 local: "TurbineLoadControllerUserDefined",
7377 qualified: "TurbineLoadControllerUserDefined",
7378 super_class: Some(377),
7379 concrete: true,
7380 origins: &["DY"],
7381 comment: "Turbine load controller function block whose dynamic behaviour is described by a user-defined model.",
7382 attrs: &[
7383 AttrDef { id: "TurbineLoadControllerUserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
7384 AttrDef { id: "TurbineLoadControllerUserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
7385 ],
7386 },
7387 ClassDef {
7388 ns: "http://iec.ch/TC57/CIM100-European#",
7389 local: "URI",
7390 qualified: "URI",
7391 super_class: None,
7392 concrete: false,
7393 origins: &["FH"],
7394 comment: "URI is a string following the rules defined by the W3C/IETF URI Planning Interest Group in a set of RFCs of which one is RFC 3305.",
7395 attrs: &[],
7396 },
7397 ClassDef {
7398 ns: "http://iec.ch/TC57/CIM100#",
7399 local: "UnderexcLim2Simplified",
7400 qualified: "UnderexcLim2Simplified",
7401 super_class: Some(385),
7402 concrete: true,
7403 origins: &["DY"],
7404 comment: "Simplified type UEL2 underexcitation limiter. This model can be derived from UnderexcLimIEEE2. The limit characteristic (look -up table) is a single straight-line, the same as UnderexcLimIEEE2 (see Figure 10.4 (p 32), IEEE 421.5-2005 Section 10.2).",
7405 attrs: &[
7406 AttrDef { id: "UnderexcLim2Simplified.kui", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain Under excitation limiter (KUI). Typical value = 0,1." },
7407 AttrDef { id: "UnderexcLim2Simplified.p0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Segment P initial point (P0). Typical value = 0." },
7408 AttrDef { id: "UnderexcLim2Simplified.p1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Segment P end point (P1). Typical value = 1." },
7409 AttrDef { id: "UnderexcLim2Simplified.q0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Segment Q initial point (Q0). Typical value = -0,31." },
7410 AttrDef { id: "UnderexcLim2Simplified.q1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Segment Q end point (Q1). Typical value = -0,1." },
7411 AttrDef { id: "UnderexcLim2Simplified.vuimax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum error signal (VUIMAX) (> UnderexcLim2Simplified.vuimin). Typical value = 1." },
7412 AttrDef { id: "UnderexcLim2Simplified.vuimin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum error signal (VUIMIN) (< UnderexcLim2Simplified.vuimax). Typical value = 0." },
7413 ],
7414 },
7415 ClassDef {
7416 ns: "http://iec.ch/TC57/CIM100#",
7417 local: "UnderexcLimIEEE1",
7418 qualified: "UnderexcLimIEEE1",
7419 super_class: Some(385),
7420 concrete: true,
7421 origins: &["DY"],
7422 comment: "Type UEL1 model which has a circular limit boundary when plotted in terms of machine reactive power vs. real power output. Reference: IEEE UEL1 421.5-2005, 10.1.",
7423 attrs: &[
7424 AttrDef { id: "UnderexcLimIEEE1.kuc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL centre setting (KUC). Typical value = 1,38." },
7425 AttrDef { id: "UnderexcLimIEEE1.kuf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL excitation system stabilizer gain (KUF). Typical value = 3,3." },
7426 AttrDef { id: "UnderexcLimIEEE1.kui", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL integral gain (KUI). Typical value = 0." },
7427 AttrDef { id: "UnderexcLimIEEE1.kul", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL proportional gain (KUL). Typical value = 100." },
7428 AttrDef { id: "UnderexcLimIEEE1.kur", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL radius setting (KUR). Typical value = 1,95." },
7429 AttrDef { id: "UnderexcLimIEEE1.tu1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL lead time constant (TU1) (>= 0). Typical value = 0." },
7430 AttrDef { id: "UnderexcLimIEEE1.tu2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL lag time constant (TU2) (>= 0). Typical value = 0,05." },
7431 AttrDef { id: "UnderexcLimIEEE1.tu3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL lead time constant (TU3) (>= 0). Typical value = 0." },
7432 AttrDef { id: "UnderexcLimIEEE1.tu4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL lag time constant (TU4) (>= 0). Typical value = 0." },
7433 AttrDef { id: "UnderexcLimIEEE1.vucmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL maximum limit for operating point phasor magnitude (VUCMAX). Typical value = 5,8." },
7434 AttrDef { id: "UnderexcLimIEEE1.vuimax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL integrator output maximum limit (VUIMAX) (> UnderexcLimIEEE1.vuimin)." },
7435 AttrDef { id: "UnderexcLimIEEE1.vuimin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL integrator output minimum limit (VUIMIN) (< UnderexcLimIEEE1.vuimax)." },
7436 AttrDef { id: "UnderexcLimIEEE1.vulmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL output maximum limit (VULMAX) (> UnderexcLimIEEE1.vulmin). Typical value = 18." },
7437 AttrDef { id: "UnderexcLimIEEE1.vulmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL output minimum limit (VULMIN) (< UnderexcLimIEEE1.vulmax). Typical value = -18." },
7438 AttrDef { id: "UnderexcLimIEEE1.vurmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL maximum limit for radius phasor magnitude (VURMAX). Typical value = 5,8." },
7439 ],
7440 },
7441 ClassDef {
7442 ns: "http://iec.ch/TC57/CIM100#",
7443 local: "UnderexcLimIEEE2",
7444 qualified: "UnderexcLimIEEE2",
7445 super_class: Some(385),
7446 concrete: true,
7447 origins: &["DY"],
7448 comment: "Type UEL2 underexcitation limiter which has either a straight-line or multi-segment characteristic when plotted in terms of machine reactive power output vs. real power output. Reference: IEEE UEL2 421.5-2005, 10.2 (limit characteristic lookup table shown in Figure 10.4 (p 32)).",
7449 attrs: &[
7450 AttrDef { id: "UnderexcLimIEEE2.k1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL terminal voltage exponent applied to real power input to UEL limit look-up table (k1). Typical value = 2." },
7451 AttrDef { id: "UnderexcLimIEEE2.k2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL terminal voltage exponent applied to reactive power output from UEL limit look-up table (k2). Typical value = 2." },
7452 AttrDef { id: "UnderexcLimIEEE2.kfb", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain associated with optional integrator feedback input signal to UEL (KFB). Typical value = 0." },
7453 AttrDef { id: "UnderexcLimIEEE2.kuf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL excitation system stabilizer gain (KUF). Typical value = 0." },
7454 AttrDef { id: "UnderexcLimIEEE2.kui", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL integral gain (KUI). Typical value = 0,5." },
7455 AttrDef { id: "UnderexcLimIEEE2.kul", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL proportional gain (KUL). Typical value = 0,8." },
7456 AttrDef { id: "UnderexcLimIEEE2.p0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Real power values for endpoints (P0). Typical value = 0." },
7457 AttrDef { id: "UnderexcLimIEEE2.p1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Real power values for endpoints (P1). Typical value = 0,3." },
7458 AttrDef { id: "UnderexcLimIEEE2.p10", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Real power values for endpoints (P10)." },
7459 AttrDef { id: "UnderexcLimIEEE2.p2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Real power values for endpoints (P2). Typical value = 0,6." },
7460 AttrDef { id: "UnderexcLimIEEE2.p3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Real power values for endpoints (P3). Typical value = 0,9." },
7461 AttrDef { id: "UnderexcLimIEEE2.p4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Real power values for endpoints (P4). Typical value = 1,02." },
7462 AttrDef { id: "UnderexcLimIEEE2.p5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Real power values for endpoints (P5)." },
7463 AttrDef { id: "UnderexcLimIEEE2.p6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Real power values for endpoints (P6)." },
7464 AttrDef { id: "UnderexcLimIEEE2.p7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Real power values for endpoints (P7)." },
7465 AttrDef { id: "UnderexcLimIEEE2.p8", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Real power values for endpoints (P8)." },
7466 AttrDef { id: "UnderexcLimIEEE2.p9", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Real power values for endpoints (P9)." },
7467 AttrDef { id: "UnderexcLimIEEE2.q0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive power values for endpoints (Q0). Typical value = -0,31." },
7468 AttrDef { id: "UnderexcLimIEEE2.q1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive power values for endpoints (Q1). Typical value = -0,31." },
7469 AttrDef { id: "UnderexcLimIEEE2.q10", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive power values for endpoints (Q10)." },
7470 AttrDef { id: "UnderexcLimIEEE2.q2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive power values for endpoints (Q2). Typical value = -0,28." },
7471 AttrDef { id: "UnderexcLimIEEE2.q3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive power values for endpoints (Q3). Typical value = -0,21." },
7472 AttrDef { id: "UnderexcLimIEEE2.q4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive power values for endpoints (Q4). Typical value = 0." },
7473 AttrDef { id: "UnderexcLimIEEE2.q5", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive power values for endpoints (Q5)." },
7474 AttrDef { id: "UnderexcLimIEEE2.q6", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive power values for endpoints (Q6)." },
7475 AttrDef { id: "UnderexcLimIEEE2.q7", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive power values for endpoints (Q7)." },
7476 AttrDef { id: "UnderexcLimIEEE2.q8", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive power values for endpoints (Q8)." },
7477 AttrDef { id: "UnderexcLimIEEE2.q9", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive power values for endpoints (Q9)." },
7478 AttrDef { id: "UnderexcLimIEEE2.tu1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL lead time constant (TU1) (>= 0). Typical value = 0." },
7479 AttrDef { id: "UnderexcLimIEEE2.tu2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL lag time constant (TU2) (>= 0). Typical value = 0." },
7480 AttrDef { id: "UnderexcLimIEEE2.tu3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL lead time constant (TU3) (>= 0). Typical value = 0." },
7481 AttrDef { id: "UnderexcLimIEEE2.tu4", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL lag time constant (TU4) (>= 0). Typical value = 0." },
7482 AttrDef { id: "UnderexcLimIEEE2.tul", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant associated with optional integrator feedback input signal to UEL (TUL) (>= 0). Typical value = 0." },
7483 AttrDef { id: "UnderexcLimIEEE2.tup", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Real power filter time constant (TUP) (>= 0). Typical value = 5." },
7484 AttrDef { id: "UnderexcLimIEEE2.tuq", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive power filter time constant (TUQ) (>= 0). Typical value = 0." },
7485 AttrDef { id: "UnderexcLimIEEE2.tuv", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage filter time constant (TUV) (>= 0). Typical value = 5." },
7486 AttrDef { id: "UnderexcLimIEEE2.vuimax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL integrator output maximum limit (VUIMAX) (> UnderexcLimIEEE2.vuimin). Typical value = 0,25." },
7487 AttrDef { id: "UnderexcLimIEEE2.vuimin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL integrator output minimum limit (VUIMIN) (< UnderexcLimIEEE2.vuimax). Typical value = 0." },
7488 AttrDef { id: "UnderexcLimIEEE2.vulmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL output maximum limit (VULMAX) (> UnderexcLimIEEE2.vulmin). Typical value = 0,25." },
7489 AttrDef { id: "UnderexcLimIEEE2.vulmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "UEL output minimum limit (VULMIN) (< UnderexcLimIEEE2.vulmax). Typical value = 0." },
7490 ],
7491 },
7492 ClassDef {
7493 ns: "http://iec.ch/TC57/CIM100#",
7494 local: "UnderexcLimX1",
7495 qualified: "UnderexcLimX1",
7496 super_class: Some(385),
7497 concrete: true,
7498 origins: &["DY"],
7499 comment: "Allis-Chalmers minimum excitation limiter.",
7500 attrs: &[
7501 AttrDef { id: "UnderexcLimX1.k", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum excitation limit slope (K) (> 0)." },
7502 AttrDef { id: "UnderexcLimX1.kf2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Differential gain (KF2)." },
7503 AttrDef { id: "UnderexcLimX1.km", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum excitation limit gain (KM)." },
7504 AttrDef { id: "UnderexcLimX1.melmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum excitation limit value (MELMAX)." },
7505 AttrDef { id: "UnderexcLimX1.tf2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Differential time constant (TF2) (>= 0)." },
7506 AttrDef { id: "UnderexcLimX1.tm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum excitation limit time constant (TM) (>= 0)." },
7507 ],
7508 },
7509 ClassDef {
7510 ns: "http://iec.ch/TC57/CIM100#",
7511 local: "UnderexcLimX2",
7512 qualified: "UnderexcLimX2",
7513 super_class: Some(385),
7514 concrete: true,
7515 origins: &["DY"],
7516 comment: "Westinghouse minimum excitation limiter.",
7517 attrs: &[
7518 AttrDef { id: "UnderexcLimX2.kf2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Differential gain (KF2)." },
7519 AttrDef { id: "UnderexcLimX2.km", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum excitation limit gain (KM)." },
7520 AttrDef { id: "UnderexcLimX2.melmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum excitation limit value (MELMAX)." },
7521 AttrDef { id: "UnderexcLimX2.qo", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation centre setting (QO)." },
7522 AttrDef { id: "UnderexcLimX2.r", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Excitation radius (R)." },
7523 AttrDef { id: "UnderexcLimX2.tf2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Differential time constant (TF2) (>= 0)." },
7524 AttrDef { id: "UnderexcLimX2.tm", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum excitation limit time constant (TM) (>= 0)." },
7525 ],
7526 },
7527 ClassDef {
7528 ns: "http://iec.ch/TC57/CIM100#",
7529 local: "UnderexcitationLimiterDynamics",
7530 qualified: "UnderexcitationLimiterDynamics",
7531 super_class: Some(91),
7532 concrete: false,
7533 origins: &["DY"],
7534 comment: "Underexcitation limiter function block whose behaviour is described by reference to a standard model or by definition of a user-defined model.",
7535 attrs: &[
7536 AttrDef { id: "UnderexcitationLimiterDynamics.ExcitationSystemDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ExcitationSystemDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Excitation system model with which this underexcitation limiter model is associated." },
7537 AttrDef { id: "UnderexcitationLimiterDynamics.RemoteInputSignal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RemoteInputSignal", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Remote input signal used by this underexcitation limiter model." },
7538 ],
7539 },
7540 ClassDef {
7541 ns: "http://iec.ch/TC57/CIM100#",
7542 local: "UnderexcitationLimiterUserDefined",
7543 qualified: "UnderexcitationLimiterUserDefined",
7544 super_class: Some(385),
7545 concrete: true,
7546 origins: &["DY"],
7547 comment: "Underexcitation limiter function block whose dynamic behaviour is described by a user-defined model.",
7548 attrs: &[
7549 AttrDef { id: "UnderexcitationLimiterUserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
7550 AttrDef { id: "UnderexcitationLimiterUserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
7551 ],
7552 },
7553 ClassDef {
7554 ns: "http://iec.ch/TC57/CIM100#",
7555 local: "VAdjIEEE",
7556 qualified: "VAdjIEEE",
7557 super_class: Some(395),
7558 concrete: true,
7559 origins: &["DY"],
7560 comment: "IEEE voltage adjuster which is used to represent the voltage adjuster in either a power factor or VAr control system. Reference: IEEE 421.5-2005, 11.1.",
7561 attrs: &[
7562 AttrDef { id: "VAdjIEEE.adjslew", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rate at which output of adjuster changes (ADJ_SLEW). Unit = s / PU. Typical value = 300." },
7563 AttrDef { id: "VAdjIEEE.taoff", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time that adjuster pulses are off (TAOFF) (>= 0). Typical value = 0,5." },
7564 AttrDef { id: "VAdjIEEE.taon", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time that adjuster pulses are on (TAON) (>= 0). Typical value = 0,1." },
7565 AttrDef { id: "VAdjIEEE.vadjf", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Set high to provide a continuous raise or lower (VADJF)." },
7566 AttrDef { id: "VAdjIEEE.vadjmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum output of the adjuster (VADJMAX) (> VAdjIEEE.vadjmin). Typical value = 1,1." },
7567 AttrDef { id: "VAdjIEEE.vadjmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum output of the adjuster (VADJMIN) (< VAdjIEEE.vadjmax). Typical value = 0,9." },
7568 ],
7569 },
7570 ClassDef {
7571 ns: "http://iec.ch/TC57/CIM100#",
7572 local: "VCompIEEEType1",
7573 qualified: "VCompIEEEType1",
7574 super_class: Some(397),
7575 concrete: true,
7576 origins: &["DY"],
7577 comment: "Terminal voltage transducer and load compensator as defined in IEEE 421.5-2005, 4. This model is common to all excitation system models described in the IEEE Standard. Parameter details: If Rc and Xc are set to zero, the load compensation is not employed and the behaviour is as a simple sensing circuit. If all parameters (Rc, Xc and Tr) are set to zero, the standard model VCompIEEEType1 is bypassed. Reference: IEEE 421.5-2005 4.",
7578 attrs: &[
7579 AttrDef { id: "VCompIEEEType1.rc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Resistive component of compensation of a generator (Rc) (>= 0)." },
7580 AttrDef { id: "VCompIEEEType1.tr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant which is used for the combined voltage sensing and compensation signal (Tr) (>= 0)." },
7581 AttrDef { id: "VCompIEEEType1.xc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive component of compensation of a generator (Xc) (>= 0)." },
7582 ],
7583 },
7584 ClassDef {
7585 ns: "http://iec.ch/TC57/CIM100#",
7586 local: "VCompIEEEType2",
7587 qualified: "VCompIEEEType2",
7588 super_class: Some(397),
7589 concrete: true,
7590 origins: &["DY"],
7591 comment: "Terminal voltage transducer and load compensator as defined in IEEE 421.5-2005, 4. This model is designed to cover the following types of compensation: reactive droop; transformer-drop or line-drop compensation; reactive differential compensation known also as cross-current compensation. Reference: IEEE 421.5-2005, 4.",
7592 attrs: &[
7593 AttrDef { id: "VCompIEEEType2.GenICompensationForGenJ", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "GenICompensationForGenJ", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Compensation of this voltage compensator's generator for current flow out of another generator." },
7594 AttrDef { id: "VCompIEEEType2.tr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant which is used for the combined voltage sensing and compensation signal (Tr) (>= 0)." },
7595 ],
7596 },
7597 ClassDef {
7598 ns: "http://iec.ch/TC57/CIM100#",
7599 local: "VSCDynamics",
7600 qualified: "VSCDynamics",
7601 super_class: Some(208),
7602 concrete: false,
7603 origins: &["DY"],
7604 comment: "VSC function block whose behaviour is described by reference to a standard model or by definition of a user-defined model.",
7605 attrs: &[
7606 AttrDef { id: "VSCDynamics.VsConverter", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "VsConverter", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Voltage source converter to which voltage source converter dynamics model applies." },
7607 ],
7608 },
7609 ClassDef {
7610 ns: "http://iec.ch/TC57/CIM100#",
7611 local: "VSCUserDefined",
7612 qualified: "VSCUserDefined",
7613 super_class: Some(390),
7614 concrete: true,
7615 origins: &["DY"],
7616 comment: "Voltage source converter (VSC) function block whose dynamic behaviour is described by a user-defined model.",
7617 attrs: &[
7618 AttrDef { id: "VSCUserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
7619 AttrDef { id: "VSCUserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
7620 ],
7621 },
7622 ClassDef {
7623 ns: "http://iec.ch/TC57/CIM100#",
7624 local: "ValueAliasSet",
7625 qualified: "ValueAliasSet",
7626 super_class: Some(213),
7627 concrete: true,
7628 origins: &["OP"],
7629 comment: "Describes the translation of a set of values into a name and is intendend to facilitate custom translations. Each ValueAliasSet has a name, description etc. A specific Measurement may represent a discrete state like Open, Closed, Intermediate etc. This requires a translation from the MeasurementValue.value number to a string, e.g. 0->'Invalid', 1->'Open', 2->'Closed', 3->'Intermediate'. Each ValueToAlias member in ValueAliasSet.Value describe a mapping for one particular value to a name.",
7630 attrs: &[
7631 AttrDef { id: "ValueAliasSet.Commands", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Command", is_list: true, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "The Commands using the set for translation." },
7632 AttrDef { id: "ValueAliasSet.Discretes", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Discrete", is_list: true, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "The Measurements using the set for translation." },
7633 AttrDef { id: "ValueAliasSet.RaiseLowerCommands", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RaiseLowerCommand", is_list: true, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "The Commands using the set for translation." },
7634 AttrDef { id: "ValueAliasSet.Values", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ValueToAlias", is_list: true, used: false, xsd: "", value_ns: "", origins: &["OP"], comment: "The ValueToAlias mappings included in the set." },
7635 ],
7636 },
7637 ClassDef {
7638 ns: "http://iec.ch/TC57/CIM100#",
7639 local: "ValueToAlias",
7640 qualified: "ValueToAlias",
7641 super_class: Some(213),
7642 concrete: true,
7643 origins: &["OP"],
7644 comment: "Describes the translation of one particular value into a name, e.g. 1 as 'Open'.",
7645 attrs: &[
7646 AttrDef { id: "ValueToAlias.ValueAliasSet", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ValueAliasSet", is_list: false, used: true, xsd: "", value_ns: "", origins: &["OP"], comment: "The ValueAliasSet having the ValueToAlias mappings." },
7647 AttrDef { id: "ValueToAlias.value", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["OP"], comment: "The value that is mapped." },
7648 ],
7649 },
7650 ClassDef {
7651 ns: "http://iec.ch/TC57/CIM100#",
7652 local: "VisibilityLayer",
7653 qualified: "VisibilityLayer",
7654 super_class: Some(213),
7655 concrete: true,
7656 origins: &["DL"],
7657 comment: "Layers are typically used for grouping diagram objects according to themes and scales. Themes are used to display or hide certain information (e.g., lakes, borders), while scales are used for hiding or displaying information depending on the current zoom level (hide text when it is too small to be read, or when it exceeds the screen size). This is also called de-cluttering. CIM based graphics exchange supports an m:n relationship between diagram objects and layers. The importing system shall convert an m:n case into an appropriate 1:n representation if the importing system does not support m:n.",
7658 attrs: &[
7659 AttrDef { id: "VisibilityLayer.VisibleObjects", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "DiagramObject", is_list: true, used: true, xsd: "", value_ns: "", origins: &["DL"], comment: "A visibility layer can contain one or more diagram objects." },
7660 AttrDef { id: "VisibilityLayer.drawingOrder", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["DL"], comment: "The drawing order for this layer. The higher the number, the later the layer and the objects within it are rendered." },
7661 ],
7662 },
7663 ClassDef {
7664 ns: "http://iec.ch/TC57/CIM100#",
7665 local: "VoltageAdjusterDynamics",
7666 qualified: "VoltageAdjusterDynamics",
7667 super_class: Some(91),
7668 concrete: false,
7669 origins: &["DY"],
7670 comment: "Voltage adjuster function block whose behaviour is described by reference to a standard model or by definition of a user-defined model.",
7671 attrs: &[
7672 AttrDef { id: "VoltageAdjusterDynamics.PFVArControllerType1Dynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PFVArControllerType1Dynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Power factor or VAr controller type 1 model with which this voltage adjuster is associated." },
7673 ],
7674 },
7675 ClassDef {
7676 ns: "http://iec.ch/TC57/CIM100#",
7677 local: "VoltageAdjusterUserDefined",
7678 qualified: "VoltageAdjusterUserDefined",
7679 super_class: Some(395),
7680 concrete: true,
7681 origins: &["DY"],
7682 comment: "Voltage adjuster function block whose dynamic behaviour is described by a user-defined model.",
7683 attrs: &[
7684 AttrDef { id: "VoltageAdjusterUserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
7685 AttrDef { id: "VoltageAdjusterUserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
7686 ],
7687 },
7688 ClassDef {
7689 ns: "http://iec.ch/TC57/CIM100#",
7690 local: "VoltageCompensatorDynamics",
7691 qualified: "VoltageCompensatorDynamics",
7692 super_class: Some(91),
7693 concrete: false,
7694 origins: &["DY"],
7695 comment: "Voltage compensator function block whose behaviour is described by reference to a standard model or by definition of a user-defined model.",
7696 attrs: &[
7697 AttrDef { id: "VoltageCompensatorDynamics.ExcitationSystemDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ExcitationSystemDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Excitation system model with which this voltage compensator is associated." },
7698 AttrDef { id: "VoltageCompensatorDynamics.RemoteInputSignal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RemoteInputSignal", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Remote input signal used by this voltage compensator model." },
7699 ],
7700 },
7701 ClassDef {
7702 ns: "http://iec.ch/TC57/CIM100#",
7703 local: "VoltageCompensatorUserDefined",
7704 qualified: "VoltageCompensatorUserDefined",
7705 super_class: Some(397),
7706 concrete: true,
7707 origins: &["DY"],
7708 comment: "Voltage compensator function block whose dynamic behaviour is described by a user-defined model.",
7709 attrs: &[
7710 AttrDef { id: "VoltageCompensatorUserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
7711 AttrDef { id: "VoltageCompensatorUserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
7712 ],
7713 },
7714 ClassDef {
7715 ns: "http://iec.ch/TC57/CIM100#",
7716 local: "VoltageLevel",
7717 qualified: "VoltageLevel",
7718 super_class: Some(99),
7719 concrete: true,
7720 origins: &["EQ", "EQBD"],
7721 comment: "A collection of equipment at one common system voltage forming a switchgear. The equipment typically consists of breakers, busbars, instrumentation, control, regulation and protection devices as well as assemblies of all these.",
7722 attrs: &[
7723 AttrDef { id: "VoltageLevel.BaseVoltage", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "BaseVoltage", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "The base voltage used for all equipment within the voltage level." },
7724 AttrDef { id: "VoltageLevel.Bays", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Bay", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "The bays within this voltage level." },
7725 AttrDef { id: "VoltageLevel.Substation", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "Substation", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ", "EQBD"], comment: "The substation of the voltage level." },
7726 AttrDef { id: "VoltageLevel.highVoltageLimit", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ", "EQBD"], comment: "The bus bar's high voltage limit. The limit applies to all equipment and nodes contained in a given VoltageLevel. It is not required that it is exchanged in pair with lowVoltageLimit. It is preferable to use operational VoltageLimit, which prevails, if present." },
7727 AttrDef { id: "VoltageLevel.lowVoltageLimit", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ", "EQBD"], comment: "The bus bar's low voltage limit. The limit applies to all equipment and nodes contained in a given VoltageLevel. It is not required that it is exchanged in pair with highVoltageLimit. It is preferable to use operational VoltageLimit, which prevails, if present." },
7728 ],
7729 },
7730 ClassDef {
7731 ns: "http://iec.ch/TC57/CIM100#",
7732 local: "VoltageLimit",
7733 qualified: "VoltageLimit",
7734 super_class: Some(248),
7735 concrete: true,
7736 origins: &["EQ", "SSH"],
7737 comment: "Operational limit applied to voltage. The use of operational VoltageLimit is preferred instead of limits defined at VoltageLevel. The operational VoltageLimits are used, if present.",
7738 attrs: &[
7739 AttrDef { id: "VoltageLimit.normalValue", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The normal limit on voltage. High or low limit nature of the limit depends upon the properties of the operational limit type. The attribute shall be a positive value or zero." },
7740 AttrDef { id: "VoltageLimit.value", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Limit on voltage. High or low limit nature of the limit depends upon the properties of the operational limit type. The attribute shall be a positive value or zero." },
7741 ],
7742 },
7743 ClassDef {
7744 ns: "http://iec.ch/TC57/CIM100#",
7745 local: "VsCapabilityCurve",
7746 qualified: "VsCapabilityCurve",
7747 super_class: Some(53),
7748 concrete: true,
7749 origins: &["EQ"],
7750 comment: "The P-Q capability curve for a voltage source converter, with P on X-axis and Qmin and Qmax on Y1-axis and Y2-axis.",
7751 attrs: &[
7752 AttrDef { id: "VsCapabilityCurve.VsConverterDCSides", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "VsConverter", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "All converters with this capability curve." },
7753 ],
7754 },
7755 ClassDef {
7756 ns: "http://iec.ch/TC57/CIM100#",
7757 local: "VsConverter",
7758 qualified: "VsConverter",
7759 super_class: Some(0),
7760 concrete: true,
7761 origins: &["EQ", "DY", "SSH", "SV"],
7762 comment: "DC side of the voltage source converter (VSC).",
7763 attrs: &[
7764 AttrDef { id: "VsConverter.CapabilityCurve", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "VsCapabilityCurve", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "Capability curve of this converter." },
7765 AttrDef { id: "VsConverter.VSCDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "VSCDynamics", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Voltage source converter dynamics model used to describe dynamic behaviour of this converter." },
7766 AttrDef { id: "VsConverter.delta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SV"], comment: "Angle between VsConverter.uv and ACDCConverter.uc. It is converter’s state variable used in power flow. The attribute shall be a positive value or zero." },
7767 AttrDef { id: "VsConverter.droop", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Droop constant. The pu value is obtained as D [kV/MW] x Sb / Ubdc. The attribute shall be a positive value." },
7768 AttrDef { id: "VsConverter.droopCompensation", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Resistance", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Compensation constant. Used to compensate for voltage drop when controlling voltage at a distant bus. The attribute shall be a positive value." },
7769 AttrDef { id: "VsConverter.maxModulationIndex", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["EQ"], comment: "The maximum quotient between the AC converter voltage (Uc) and DC voltage (Ud). A factor typically less than 1. It is converter’s configuration data used in power flow." },
7770 AttrDef { id: "VsConverter.pPccControl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "VsPpccControlKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["SSH"], comment: "Kind of control of real power and/or DC voltage." },
7771 AttrDef { id: "VsConverter.qPccControl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "VsQpccControlKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["SSH"], comment: "Kind of reactive power control." },
7772 AttrDef { id: "VsConverter.qShare", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PerCent", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Reactive power sharing factor among parallel converters on Uac control. The attribute shall be a positive value or zero." },
7773 AttrDef { id: "VsConverter.targetPWMfactor", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Magnitude of pulse-modulation factor. The attribute shall be a positive value." },
7774 AttrDef { id: "VsConverter.targetPhasePcc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Phase target at AC side, at point of common coupling. The attribute shall be a positive value." },
7775 AttrDef { id: "VsConverter.targetPowerFactorPcc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Power factor target at the AC side, at point of common coupling. The attribute shall be a positive value." },
7776 AttrDef { id: "VsConverter.targetQpcc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "ReactivePower", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Reactive power injection target in AC grid, at point of common coupling. Load sign convention is used, i.e. positive sign means flow out from a node." },
7777 AttrDef { id: "VsConverter.targetUpcc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SSH"], comment: "Voltage target in AC grid, at point of common coupling. The attribute shall be a positive value." },
7778 AttrDef { id: "VsConverter.uv", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Voltage", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["SV"], comment: "Line-to-line voltage on the valve side of the converter transformer. It is converter’s state variable, result from power flow. The attribute shall be a positive value." },
7779 ],
7780 },
7781 ClassDef {
7782 ns: "http://iec.ch/TC57/CIM100#",
7783 local: "WaveTrap",
7784 qualified: "WaveTrap",
7785 super_class: Some(21),
7786 concrete: true,
7787 origins: &["EQ"],
7788 comment: "Line traps are devices that impede high frequency power line carrier signals yet present a negligible impedance at the main power frequency.",
7789 attrs: &[],
7790 },
7791 ClassDef {
7792 ns: "http://iec.ch/TC57/CIM100#",
7793 local: "WindAeroConstIEC",
7794 qualified: "WindAeroConstIEC",
7795 super_class: Some(213),
7796 concrete: true,
7797 origins: &["DY"],
7798 comment: "Constant aerodynamic torque model which assumes that the aerodynamic torque is constant. Reference: IEC 61400-27-1:2015, 5.6.1.1.",
7799 attrs: &[
7800 AttrDef { id: "WindAeroConstIEC.WindGenTurbineType1aIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindGenTurbineType1aIEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 1A model with which this wind aerodynamic model is associated." },
7801 ],
7802 },
7803 ClassDef {
7804 ns: "http://iec.ch/TC57/CIM100#",
7805 local: "WindAeroOneDimIEC",
7806 qualified: "WindAeroOneDimIEC",
7807 super_class: Some(213),
7808 concrete: true,
7809 origins: &["DY"],
7810 comment: "One-dimensional aerodynamic model. Reference: IEC 61400-27-1:2015, 5.6.1.2.",
7811 attrs: &[
7812 AttrDef { id: "WindAeroOneDimIEC.WindTurbineType3IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType3IEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 3 model with which this wind aerodynamic model is associated." },
7813 AttrDef { id: "WindAeroOneDimIEC.ka", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Aerodynamic gain (ka). It is a type-dependent parameter." },
7814 AttrDef { id: "WindAeroOneDimIEC.thetaomega", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Initial pitch angle (thetaomega0). It is a case-dependent parameter." },
7815 ],
7816 },
7817 ClassDef {
7818 ns: "http://iec.ch/TC57/CIM100#",
7819 local: "WindAeroTwoDimIEC",
7820 qualified: "WindAeroTwoDimIEC",
7821 super_class: Some(213),
7822 concrete: true,
7823 origins: &["DY"],
7824 comment: "Two-dimensional aerodynamic model. Reference: IEC 61400-27-1:2015, 5.6.1.3.",
7825 attrs: &[
7826 AttrDef { id: "WindAeroTwoDimIEC.WindTurbineType3IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType3IEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 3 model with which this wind aerodynamic model is associated." },
7827 AttrDef { id: "WindAeroTwoDimIEC.dpomega", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Partial derivative of aerodynamic power with respect to changes in WTR speed (dpomega). It is a type-dependent parameter." },
7828 AttrDef { id: "WindAeroTwoDimIEC.dptheta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Partial derivative of aerodynamic power with respect to changes in pitch angle (dptheta). It is a type-dependent parameter." },
7829 AttrDef { id: "WindAeroTwoDimIEC.dpv1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Partial derivative (dpv1). It is a type-dependent parameter." },
7830 AttrDef { id: "WindAeroTwoDimIEC.omegazero", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rotor speed if the wind turbine is not derated (omega0). It is a type-dependent parameter." },
7831 AttrDef { id: "WindAeroTwoDimIEC.pavail", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Available aerodynamic power (pavail). It is a case-dependent parameter." },
7832 AttrDef { id: "WindAeroTwoDimIEC.thetav2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Blade angle at twice rated wind speed (thetav2). It is a type-dependent parameter." },
7833 AttrDef { id: "WindAeroTwoDimIEC.thetazero", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pitch angle if the wind turbine is not derated (theta0). It is a case-dependent parameter." },
7834 ],
7835 },
7836 ClassDef {
7837 ns: "http://iec.ch/TC57/CIM100#",
7838 local: "WindContCurrLimIEC",
7839 qualified: "WindContCurrLimIEC",
7840 super_class: Some(213),
7841 concrete: true,
7842 origins: &["DY"],
7843 comment: "Current limitation model. The current limitation model combines the physical limits and the control limits. Reference: IEC 61400-27-1:2015, 5.6.5.8.",
7844 attrs: &[
7845 AttrDef { id: "WindContCurrLimIEC.WindDynamicsLookupTable", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindDynamicsLookupTable", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "The wind dynamics lookup table associated with this current control limitation model." },
7846 AttrDef { id: "WindContCurrLimIEC.WindTurbineType3or4IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType3or4IEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 3 or type 4 model with which this wind control current limitation model is associated." },
7847 AttrDef { id: "WindContCurrLimIEC.imax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum continuous current at the wind turbine terminals (imax). It is a type-dependent parameter." },
7848 AttrDef { id: "WindContCurrLimIEC.imaxdip", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum current during voltage dip at the wind turbine terminals (imaxdip). It is a project-dependent parameter." },
7849 AttrDef { id: "WindContCurrLimIEC.kpqu", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Partial derivative of reactive current limit (Kpqu) versus voltage. It is a type-dependent parameter." },
7850 AttrDef { id: "WindContCurrLimIEC.mdfslim", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Limitation of type 3 stator current (MDFSLim). MDFSLim = 1 for wind turbines type 4. It is a type-dependent parameter. false= total current limitation (0 in the IEC model) true=stator current limitation (1 in the IEC model)." },
7851 AttrDef { id: "WindContCurrLimIEC.mqpri", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Prioritisation of Q control during UVRT (Mqpri). It is a project-dependent parameter. true = reactive power priority (1 in the IEC model) false = active power priority (0 in the IEC model)." },
7852 AttrDef { id: "WindContCurrLimIEC.tufiltcl", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage measurement filter time constant (Tufiltcl) (>= 0). It is a type-dependent parameter." },
7853 AttrDef { id: "WindContCurrLimIEC.upqumax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Wind turbine voltage in the operation point where zero reactive current can be delivered (upqumax). It is a type-dependent parameter." },
7854 ],
7855 },
7856 ClassDef {
7857 ns: "http://iec.ch/TC57/CIM100#",
7858 local: "WindContPType3IEC",
7859 qualified: "WindContPType3IEC",
7860 super_class: Some(213),
7861 concrete: true,
7862 origins: &["DY"],
7863 comment: "P control model type 3. Reference: IEC 61400-27-1:2015, 5.6.5.4.",
7864 attrs: &[
7865 AttrDef { id: "WindContPType3IEC.WindDynamicsLookupTable", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindDynamicsLookupTable", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "The wind dynamics lookup table associated with this P control type 3 model." },
7866 AttrDef { id: "WindContPType3IEC.WindTurbineType3IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType3IEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 3 model with which this wind control P type 3 model is associated." },
7867 AttrDef { id: "WindContPType3IEC.dpmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum wind turbine power ramp rate (dpmax). It is a type-dependent parameter." },
7868 AttrDef { id: "WindContPType3IEC.dprefmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum ramp rate of wind turbine reference power (dprefmax). It is a project-dependent parameter." },
7869 AttrDef { id: "WindContPType3IEC.dprefmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum ramp rate of wind turbine reference power (dprefmin). It is a project-dependent parameter." },
7870 AttrDef { id: "WindContPType3IEC.dthetamax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Ramp limitation of torque, required in some grid codes (dtmax). It is a project-dependent parameter." },
7871 AttrDef { id: "WindContPType3IEC.dthetamaxuvrt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Limitation of torque rise rate during UVRT (dthetamaxUVRT). It is a project-dependent parameter." },
7872 AttrDef { id: "WindContPType3IEC.kdtd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Gain for active drive train damping (KDTD). It is a type-dependent parameter." },
7873 AttrDef { id: "WindContPType3IEC.kip", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PI controller integration parameter (KIp). It is a type-dependent parameter." },
7874 AttrDef { id: "WindContPType3IEC.kpp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "PI controller proportional gain (KPp). It is a type-dependent parameter." },
7875 AttrDef { id: "WindContPType3IEC.mpuvrt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Enable UVRT power control mode (MpUVRT). It is a project-dependent parameter. true = voltage control (1 in the IEC model) false = reactive power control (0 in the IEC model)." },
7876 AttrDef { id: "WindContPType3IEC.omegadtd", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Active drive train damping frequency (omegaDTD). It can be calculated from two mass model parameters. It is a type-dependent parameter." },
7877 AttrDef { id: "WindContPType3IEC.omegaoffset", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Offset to reference value that limits controller action during rotor speed changes (omegaoffset). It is a case-dependent parameter." },
7878 AttrDef { id: "WindContPType3IEC.pdtdmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum active drive train damping power (pDTDmax). It is a type-dependent parameter." },
7879 AttrDef { id: "WindContPType3IEC.tdvs", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time delay after deep voltage sags (TDVS) (>= 0). It is a project-dependent parameter." },
7880 AttrDef { id: "WindContPType3IEC.thetaemin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum electrical generator torque (temin). It is a type-dependent parameter." },
7881 AttrDef { id: "WindContPType3IEC.thetauscale", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage scaling factor of reset-torque (tuscale). It is a project-dependent parameter." },
7882 AttrDef { id: "WindContPType3IEC.tomegafiltp3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter time constant for generator speed measurement (Tomegafiltp3) (>= 0). It is a type-dependent parameter." },
7883 AttrDef { id: "WindContPType3IEC.tomegaref", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant in speed reference filter (Tomega,ref) (>= 0). It is a type-dependent parameter." },
7884 AttrDef { id: "WindContPType3IEC.tpfiltp3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter time constant for power measurement (Tpfiltp3) (>= 0). It is a type-dependent parameter." },
7885 AttrDef { id: "WindContPType3IEC.tpord", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant in power order lag (Tpord). It is a type-dependent parameter." },
7886 AttrDef { id: "WindContPType3IEC.tufiltp3", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter time constant for voltage measurement (Tufiltp3) (>= 0). It is a type-dependent parameter." },
7887 AttrDef { id: "WindContPType3IEC.udvs", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage limit for hold UVRT status after deep voltage sags (uDVS). It is a project-dependent parameter." },
7888 AttrDef { id: "WindContPType3IEC.updip", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage dip threshold for P-control (uPdip). Part of turbine control, often different (e.g 0.8) from converter thresholds. It is a project-dependent parameter." },
7889 AttrDef { id: "WindContPType3IEC.zeta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Coefficient for active drive train damping (zeta). It is a type-dependent parameter." },
7890 ],
7891 },
7892 ClassDef {
7893 ns: "http://iec.ch/TC57/CIM100#",
7894 local: "WindContPType4aIEC",
7895 qualified: "WindContPType4aIEC",
7896 super_class: Some(213),
7897 concrete: true,
7898 origins: &["DY"],
7899 comment: "P control model type 4A. Reference: IEC 61400-27-1:2015, 5.6.5.5.",
7900 attrs: &[
7901 AttrDef { id: "WindContPType4aIEC.WindTurbineType4aIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType4aIEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 4A model with which this wind control P type 4A model is associated." },
7902 AttrDef { id: "WindContPType4aIEC.dpmaxp4a", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum wind turbine power ramp rate (dpmaxp4A). It is a project-dependent parameter." },
7903 AttrDef { id: "WindContPType4aIEC.tpordp4a", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant in power order lag (Tpordp4A) (>= 0). It is a type-dependent parameter." },
7904 AttrDef { id: "WindContPType4aIEC.tufiltp4a", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage measurement filter time constant (Tufiltp4A) (>= 0). It is a type-dependent parameter." },
7905 ],
7906 },
7907 ClassDef {
7908 ns: "http://iec.ch/TC57/CIM100#",
7909 local: "WindContPType4bIEC",
7910 qualified: "WindContPType4bIEC",
7911 super_class: Some(213),
7912 concrete: true,
7913 origins: &["DY"],
7914 comment: "P control model type 4B. Reference: IEC 61400-27-1:2015, 5.6.5.6.",
7915 attrs: &[
7916 AttrDef { id: "WindContPType4bIEC.WindTurbineType4bIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType4bIEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 4B model with which this wind control P type 4B model is associated." },
7917 AttrDef { id: "WindContPType4bIEC.dpmaxp4b", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum wind turbine power ramp rate (dpmaxp4B). It is a project-dependent parameter." },
7918 AttrDef { id: "WindContPType4bIEC.tpaero", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant in aerodynamic power response (Tpaero) (>= 0). It is a type-dependent parameter." },
7919 AttrDef { id: "WindContPType4bIEC.tpordp4b", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant in power order lag (Tpordp4B) (>= 0). It is a type-dependent parameter." },
7920 AttrDef { id: "WindContPType4bIEC.tufiltp4b", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage measurement filter time constant (Tufiltp4B) (>= 0). It is a type-dependent parameter." },
7921 ],
7922 },
7923 ClassDef {
7924 ns: "http://iec.ch/TC57/CIM100#",
7925 local: "WindContPitchAngleIEC",
7926 qualified: "WindContPitchAngleIEC",
7927 super_class: Some(213),
7928 concrete: true,
7929 origins: &["DY"],
7930 comment: "Pitch angle control model. Reference: IEC 61400-27-1:2015, 5.6.5.2.",
7931 attrs: &[
7932 AttrDef { id: "WindContPitchAngleIEC.WindTurbineType3IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType3IEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 3 model with which this pitch control model is associated." },
7933 AttrDef { id: "WindContPitchAngleIEC.dthetamax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum pitch positive ramp rate (dthetamax) (> WindContPitchAngleIEC.dthetamin). It is a type-dependent parameter. Unit = degrees / s." },
7934 AttrDef { id: "WindContPitchAngleIEC.dthetamin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum pitch negative ramp rate (dthetamin) (< WindContPitchAngleIEC.dthetamax). It is a type-dependent parameter. Unit = degrees / s." },
7935 AttrDef { id: "WindContPitchAngleIEC.kic", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power PI controller integration gain (KIc). It is a type-dependent parameter." },
7936 AttrDef { id: "WindContPitchAngleIEC.kiomega", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Speed PI controller integration gain (KIomega). It is a type-dependent parameter." },
7937 AttrDef { id: "WindContPitchAngleIEC.kpc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power PI controller proportional gain (KPc). It is a type-dependent parameter." },
7938 AttrDef { id: "WindContPitchAngleIEC.kpomega", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Speed PI controller proportional gain (KPomega). It is a type-dependent parameter." },
7939 AttrDef { id: "WindContPitchAngleIEC.kpx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pitch cross coupling gain (KPX). It is a type-dependent parameter." },
7940 AttrDef { id: "WindContPitchAngleIEC.thetamax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum pitch angle (thetamax) (> WindContPitchAngleIEC.thetamin). It is a type-dependent parameter." },
7941 AttrDef { id: "WindContPitchAngleIEC.thetamin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "AngleDegrees", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum pitch angle (thetamin) (< WindContPitchAngleIEC.thetamax). It is a type-dependent parameter." },
7942 AttrDef { id: "WindContPitchAngleIEC.ttheta", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Pitch time constant (ttheta) (>= 0). It is a type-dependent parameter." },
7943 ],
7944 },
7945 ClassDef {
7946 ns: "http://iec.ch/TC57/CIM100#",
7947 local: "WindContQIEC",
7948 qualified: "WindContQIEC",
7949 super_class: Some(213),
7950 concrete: true,
7951 origins: &["DY"],
7952 comment: "Q control model. Reference: IEC 61400-27-1:2015, 5.6.5.7.",
7953 attrs: &[
7954 AttrDef { id: "WindContQIEC.WindTurbineType3or4IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType3or4IEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 3 or type 4 model with which this reactive control model is associated." },
7955 AttrDef { id: "WindContQIEC.iqh1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum reactive current injection during dip (iqh1). It is a type-dependent parameter." },
7956 AttrDef { id: "WindContQIEC.iqmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum reactive current injection (iqmax) (> WindContQIEC.iqmin). It is a type-dependent parameter." },
7957 AttrDef { id: "WindContQIEC.iqmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum reactive current injection (iqmin) (< WindContQIEC.iqmax). It is a type-dependent parameter." },
7958 AttrDef { id: "WindContQIEC.iqpost", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Post fault reactive current injection (iqpost). It is a project-dependent parameter." },
7959 AttrDef { id: "WindContQIEC.kiq", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive power PI controller integration gain (KI,q). It is a type-dependent parameter." },
7960 AttrDef { id: "WindContQIEC.kiu", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage PI controller integration gain (KI,u). It is a type-dependent parameter." },
7961 AttrDef { id: "WindContQIEC.kpq", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive power PI controller proportional gain (KP,q). It is a type-dependent parameter." },
7962 AttrDef { id: "WindContQIEC.kpu", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage PI controller proportional gain (KP,u). It is a type-dependent parameter." },
7963 AttrDef { id: "WindContQIEC.kqv", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage scaling factor for UVRT current (Kqv). It is a project-dependent parameter." },
7964 AttrDef { id: "WindContQIEC.rdroop", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Resistive component of voltage drop impedance (rdroop) (>= 0). It is a project-dependent parameter." },
7965 AttrDef { id: "WindContQIEC.tpfiltq", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power measurement filter time constant (Tpfiltq) (>= 0). It is a type-dependent parameter." },
7966 AttrDef { id: "WindContQIEC.tpost", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Length of time period where post fault reactive power is injected (Tpost) (>= 0). It is a project-dependent parameter." },
7967 AttrDef { id: "WindContQIEC.tqord", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant in reactive power order lag (Tqord) (>= 0). It is a type-dependent parameter." },
7968 AttrDef { id: "WindContQIEC.tufiltq", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage measurement filter time constant (Tufiltq) (>= 0). It is a type-dependent parameter." },
7969 AttrDef { id: "WindContQIEC.udb1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage deadband lower limit (udb1). It is a type-dependent parameter." },
7970 AttrDef { id: "WindContQIEC.udb2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage deadband upper limit (udb2). It is a type-dependent parameter." },
7971 AttrDef { id: "WindContQIEC.umax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum voltage in voltage PI controller integral term (umax) (> WindContQIEC.umin). It is a type-dependent parameter." },
7972 AttrDef { id: "WindContQIEC.umin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum voltage in voltage PI controller integral term (umin) (< WindContQIEC.umax). It is a type-dependent parameter." },
7973 AttrDef { id: "WindContQIEC.uqdip", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage threshold for UVRT detection in Q control (uqdip). It is a type-dependent parameter." },
7974 AttrDef { id: "WindContQIEC.uref0", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "User-defined bias in voltage reference (uref0). It is a case-dependent parameter." },
7975 AttrDef { id: "WindContQIEC.windQcontrolModesType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "WindQcontrolModeKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Types of general wind turbine Q control modes (MqG). It is a project-dependent parameter." },
7976 AttrDef { id: "WindContQIEC.windUVRTQcontrolModesType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "WindUVRTQcontrolModeKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Types of UVRT Q control modes (MqUVRT). It is a project-dependent parameter." },
7977 AttrDef { id: "WindContQIEC.xdroop", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Inductive component of voltage drop impedance (xdroop) (>= 0). It is a project-dependent parameter." },
7978 ],
7979 },
7980 ClassDef {
7981 ns: "http://iec.ch/TC57/CIM100#",
7982 local: "WindContQLimIEC",
7983 qualified: "WindContQLimIEC",
7984 super_class: Some(213),
7985 concrete: true,
7986 origins: &["DY"],
7987 comment: "Constant Q limitation model. Reference: IEC 61400-27-1:2015, 5.6.5.9.",
7988 attrs: &[
7989 AttrDef { id: "WindContQLimIEC.WindTurbineType3or4IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType3or4IEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind generator type 3 or type 4 model with which this constant Q limitation model is associated." },
7990 AttrDef { id: "WindContQLimIEC.qmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum reactive power (qmax) (> WindContQLimIEC.qmin). It is a type-dependent parameter." },
7991 AttrDef { id: "WindContQLimIEC.qmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum reactive power (qmin) (< WindContQLimIEC.qmax). It is a type-dependent parameter." },
7992 ],
7993 },
7994 ClassDef {
7995 ns: "http://iec.ch/TC57/CIM100#",
7996 local: "WindContQPQULimIEC",
7997 qualified: "WindContQPQULimIEC",
7998 super_class: Some(213),
7999 concrete: true,
8000 origins: &["DY"],
8001 comment: "QP and QU limitation model. Reference: IEC 61400-27-1:2015, 5.6.5.10.",
8002 attrs: &[
8003 AttrDef { id: "WindContQPQULimIEC.WindDynamicsLookupTable", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindDynamicsLookupTable", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "The wind dynamics lookup table associated with this QP and QU limitation model." },
8004 AttrDef { id: "WindContQPQULimIEC.WindTurbineType3or4IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType3or4IEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind generator type 3 or type 4 model with which this QP and QU limitation model is associated." },
8005 AttrDef { id: "WindContQPQULimIEC.tpfiltql", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power measurement filter time constant for Q capacity (Tpfiltql) (>= 0). It is a type-dependent parameter." },
8006 AttrDef { id: "WindContQPQULimIEC.tufiltql", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage measurement filter time constant for Q capacity (Tufiltql) (>= 0). It is a type-dependent parameter." },
8007 ],
8008 },
8009 ClassDef {
8010 ns: "http://iec.ch/TC57/CIM100#",
8011 local: "WindContRotorRIEC",
8012 qualified: "WindContRotorRIEC",
8013 super_class: Some(213),
8014 concrete: true,
8015 origins: &["DY"],
8016 comment: "Rotor resistance control model. Reference: IEC 61400-27-1:2015, 5.6.5.3.",
8017 attrs: &[
8018 AttrDef { id: "WindContRotorRIEC.WindDynamicsLookupTable", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindDynamicsLookupTable", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "The wind dynamics lookup table associated with this rotor resistance control model." },
8019 AttrDef { id: "WindContRotorRIEC.WindGenTurbineType2IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindGenTurbineType2IEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 2 model with whitch this wind control rotor resistance model is associated." },
8020 AttrDef { id: "WindContRotorRIEC.kirr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Integral gain in rotor resistance PI controller (KIrr). It is a type-dependent parameter." },
8021 AttrDef { id: "WindContRotorRIEC.komegafilt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter gain for generator speed measurement (Komegafilt). It is a type-dependent parameter." },
8022 AttrDef { id: "WindContRotorRIEC.kpfilt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter gain for power measurement (Kpfilt). It is a type-dependent parameter." },
8023 AttrDef { id: "WindContRotorRIEC.kprr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Proportional gain in rotor resistance PI controller (KPrr). It is a type-dependent parameter." },
8024 AttrDef { id: "WindContRotorRIEC.rmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum rotor resistance (rmax) (> WindContRotorRIEC.rmin). It is a type-dependent parameter." },
8025 AttrDef { id: "WindContRotorRIEC.rmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum rotor resistance (rmin) (< WindContRotorRIEC.rmax). It is a type-dependent parameter." },
8026 AttrDef { id: "WindContRotorRIEC.tomegafiltrr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter time constant for generator speed measurement (Tomegafiltrr) (>= 0). It is a type-dependent parameter." },
8027 AttrDef { id: "WindContRotorRIEC.tpfiltrr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter time constant for power measurement (Tpfiltrr) (>= 0). It is a type-dependent parameter." },
8028 ],
8029 },
8030 ClassDef {
8031 ns: "http://iec.ch/TC57/CIM100#",
8032 local: "WindDynamicsLookupTable",
8033 qualified: "WindDynamicsLookupTable",
8034 super_class: Some(213),
8035 concrete: true,
8036 origins: &["DY"],
8037 comment: "Look up table for the purpose of wind standard models.",
8038 attrs: &[
8039 AttrDef { id: "WindDynamicsLookupTable.WindContCurrLimIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindContCurrLimIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "The current control limitation model with which this wind dynamics lookup table is associated." },
8040 AttrDef { id: "WindDynamicsLookupTable.WindContPType3IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindContPType3IEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "The P control type 3 model with which this wind dynamics lookup table is associated." },
8041 AttrDef { id: "WindDynamicsLookupTable.WindContQPQULimIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindContQPQULimIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "The QP and QU limitation model with which this wind dynamics lookup table is associated." },
8042 AttrDef { id: "WindDynamicsLookupTable.WindContRotorRIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindContRotorRIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "The rotor resistance control model with which this wind dynamics lookup table is associated." },
8043 AttrDef { id: "WindDynamicsLookupTable.WindGenType3bIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindGenType3bIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "The generator type 3B model with which this wind dynamics lookup table is associated." },
8044 AttrDef { id: "WindDynamicsLookupTable.WindPitchContPowerIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindPitchContPowerIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "The pitch control power model with which this wind dynamics lookup table is associated." },
8045 AttrDef { id: "WindDynamicsLookupTable.WindPlantFreqPcontrolIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindPlantFreqPcontrolIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "The frequency and active power wind plant control model with which this wind dynamics lookup table is associated." },
8046 AttrDef { id: "WindDynamicsLookupTable.WindPlantReactiveControlIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindPlantReactiveControlIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "The voltage and reactive power wind plant control model with which this wind dynamics lookup table is associated." },
8047 AttrDef { id: "WindDynamicsLookupTable.WindProtectionIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindProtectionIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "The grid protection model with which this wind dynamics lookup table is associated." },
8048 AttrDef { id: "WindDynamicsLookupTable.input", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Input value (x) for the lookup table function." },
8049 AttrDef { id: "WindDynamicsLookupTable.lookupTableFunctionType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "WindLookupTableFunctionKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Type of the lookup table function." },
8050 AttrDef { id: "WindDynamicsLookupTable.output", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Output value (y) for the lookup table function." },
8051 AttrDef { id: "WindDynamicsLookupTable.sequence", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Integer", is_list: false, used: true, xsd: "integer", value_ns: "", origins: &["DY"], comment: "Sequence numbers of the pairs of the input (x) and the output (y) of the lookup table function." },
8052 ],
8053 },
8054 ClassDef {
8055 ns: "http://iec.ch/TC57/CIM100#",
8056 local: "WindGenTurbineType1aIEC",
8057 qualified: "WindGenTurbineType1aIEC",
8058 super_class: Some(436),
8059 concrete: true,
8060 origins: &["DY"],
8061 comment: "Wind turbine IEC type 1A. Reference: IEC 61400-27-1:2015, 5.5.2.2.",
8062 attrs: &[
8063 AttrDef { id: "WindGenTurbineType1aIEC.WindAeroConstIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindAeroConstIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind aerodynamic model associated with this wind turbine type 1A model." },
8064 ],
8065 },
8066 ClassDef {
8067 ns: "http://iec.ch/TC57/CIM100#",
8068 local: "WindGenTurbineType1bIEC",
8069 qualified: "WindGenTurbineType1bIEC",
8070 super_class: Some(436),
8071 concrete: true,
8072 origins: &["DY"],
8073 comment: "Wind turbine IEC type 1B. Reference: IEC 61400-27-1:2015, 5.5.2.3.",
8074 attrs: &[
8075 AttrDef { id: "WindGenTurbineType1bIEC.WindPitchContPowerIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindPitchContPowerIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Pitch control power model associated with this wind turbine type 1B model." },
8076 ],
8077 },
8078 ClassDef {
8079 ns: "http://iec.ch/TC57/CIM100#",
8080 local: "WindGenTurbineType2IEC",
8081 qualified: "WindGenTurbineType2IEC",
8082 super_class: Some(436),
8083 concrete: true,
8084 origins: &["DY"],
8085 comment: "Wind turbine IEC type 2. Reference: IEC 61400-27-1:2015, 5.5.3.",
8086 attrs: &[
8087 AttrDef { id: "WindGenTurbineType2IEC.WindContRotorRIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindContRotorRIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind control rotor resistance model associated with wind turbine type 2 model." },
8088 AttrDef { id: "WindGenTurbineType2IEC.WindPitchContPowerIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindPitchContPowerIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Pitch control power model associated with this wind turbine type 2 model." },
8089 ],
8090 },
8091 ClassDef {
8092 ns: "http://iec.ch/TC57/CIM100#",
8093 local: "WindGenType3IEC",
8094 qualified: "WindGenType3IEC",
8095 super_class: Some(213),
8096 concrete: false,
8097 origins: &["DY"],
8098 comment: "Parent class supporting relationships to IEC wind turbines type 3 generator models of IEC type 3A and 3B.",
8099 attrs: &[
8100 AttrDef { id: "WindGenType3IEC.WindTurbineType3IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType3IEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 3 model with which this wind generator type 3 is associated." },
8101 AttrDef { id: "WindGenType3IEC.dipmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum active current ramp rate (dipmax). It is a project-dependent parameter." },
8102 AttrDef { id: "WindGenType3IEC.diqmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum reactive current ramp rate (diqmax). It is a project-dependent parameter." },
8103 AttrDef { id: "WindGenType3IEC.xs", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Electromagnetic transient reactance (xS). It is a type-dependent parameter." },
8104 ],
8105 },
8106 ClassDef {
8107 ns: "http://iec.ch/TC57/CIM100#",
8108 local: "WindGenType3aIEC",
8109 qualified: "WindGenType3aIEC",
8110 super_class: Some(420),
8111 concrete: true,
8112 origins: &["DY"],
8113 comment: "IEC type 3A generator set model. Reference: IEC 61400-27-1:2015, 5.6.3.2.",
8114 attrs: &[
8115 AttrDef { id: "WindGenType3aIEC.WindTurbineType4IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType4IEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 4 model with which this wind generator type 3A model is associated." },
8116 AttrDef { id: "WindGenType3aIEC.kpc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Current PI controller proportional gain (KPc). It is a type-dependent parameter." },
8117 AttrDef { id: "WindGenType3aIEC.tic", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Current PI controller integration time constant (TIc) (>= 0). It is a type-dependent parameter." },
8118 ],
8119 },
8120 ClassDef {
8121 ns: "http://iec.ch/TC57/CIM100#",
8122 local: "WindGenType3bIEC",
8123 qualified: "WindGenType3bIEC",
8124 super_class: Some(420),
8125 concrete: true,
8126 origins: &["DY"],
8127 comment: "IEC type 3B generator set model. Reference: IEC 61400-27-1:2015, 5.6.3.3.",
8128 attrs: &[
8129 AttrDef { id: "WindGenType3bIEC.WindDynamicsLookupTable", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindDynamicsLookupTable", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "The wind dynamics lookup table associated with this generator type 3B model." },
8130 AttrDef { id: "WindGenType3bIEC.mwtcwp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Crowbar control mode (MWTcwp). It is a case-dependent parameter. true = 1 in the IEC model false = 0 in the IEC model." },
8131 AttrDef { id: "WindGenType3bIEC.tg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Current generation time constant (Tg) (>= 0). It is a type-dependent parameter." },
8132 AttrDef { id: "WindGenType3bIEC.two", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant for crowbar washout filter (Two) (>= 0). It is a case-dependent parameter." },
8133 ],
8134 },
8135 ClassDef {
8136 ns: "http://iec.ch/TC57/CIM100#",
8137 local: "WindGenType4IEC",
8138 qualified: "WindGenType4IEC",
8139 super_class: Some(213),
8140 concrete: true,
8141 origins: &["DY"],
8142 comment: "IEC type 4 generator set model. Reference: IEC 61400-27-1:2015, 5.6.3.4.",
8143 attrs: &[
8144 AttrDef { id: "WindGenType4IEC.WindTurbineType4aIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType4aIEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 4A model with which this wind generator type 4 model is associated." },
8145 AttrDef { id: "WindGenType4IEC.WindTurbineType4bIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType4bIEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 4B model with which this wind generator type 4 model is associated." },
8146 AttrDef { id: "WindGenType4IEC.dipmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum active current ramp rate (dipmax). It is a project-dependent parameter." },
8147 AttrDef { id: "WindGenType4IEC.diqmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum reactive current ramp rate (diqmax). It is a project-dependent parameter." },
8148 AttrDef { id: "WindGenType4IEC.diqmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum reactive current ramp rate (diqmin). It is a project-dependent parameter." },
8149 AttrDef { id: "WindGenType4IEC.tg", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant (Tg) (>= 0). It is a type-dependent parameter." },
8150 ],
8151 },
8152 ClassDef {
8153 ns: "http://iec.ch/TC57/CIM100#",
8154 local: "WindGeneratingUnit",
8155 qualified: "WindGeneratingUnit",
8156 super_class: Some(169),
8157 concrete: true,
8158 origins: &["EQ", "SSH"],
8159 comment: "A wind driven generating unit, connected to the grid by means of a rotating machine. May be used to represent a single turbine or an aggregation.",
8160 attrs: &[
8161 AttrDef { id: "WindGeneratingUnit.WindPowerPlant", ns: "http://iec.ch/TC57/CIM100-European#", kind: AttrKind::Association, range: "WindPowerPlant", is_list: false, used: true, xsd: "", value_ns: "", origins: &["EQ"], comment: "A wind power plant may have wind generating units." },
8162 AttrDef { id: "WindGeneratingUnit.windGenUnitType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "WindGenUnitKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["EQ"], comment: "The kind of wind generating unit." },
8163 ],
8164 },
8165 ClassDef {
8166 ns: "http://iec.ch/TC57/CIM100#",
8167 local: "WindMechIEC",
8168 qualified: "WindMechIEC",
8169 super_class: Some(213),
8170 concrete: true,
8171 origins: &["DY"],
8172 comment: "Two mass model. Reference: IEC 61400-27-1:2015, 5.6.2.1.",
8173 attrs: &[
8174 AttrDef { id: "WindMechIEC.WindTurbineType1or2IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType1or2IEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind generator type 1 or type 2 model with which this wind mechanical model is associated." },
8175 AttrDef { id: "WindMechIEC.WindTurbineType3IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType3IEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 3 model with which this wind mechanical model is associated." },
8176 AttrDef { id: "WindMechIEC.WindTurbineType4bIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType4bIEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 4B model with which this wind mechanical model is associated." },
8177 AttrDef { id: "WindMechIEC.cdrt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Drive train damping (cdrt). It is a type-dependent parameter." },
8178 AttrDef { id: "WindMechIEC.hgen", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Inertia constant of generator (Hgen) (>= 0). It is a type-dependent parameter." },
8179 AttrDef { id: "WindMechIEC.hwtr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Inertia constant of wind turbine rotor (HWTR) (>= 0). It is a type-dependent parameter." },
8180 AttrDef { id: "WindMechIEC.kdrt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Drive train stiffness (kdrt). It is a type-dependent parameter." },
8181 ],
8182 },
8183 ClassDef {
8184 ns: "http://iec.ch/TC57/CIM100#",
8185 local: "WindPitchContPowerIEC",
8186 qualified: "WindPitchContPowerIEC",
8187 super_class: Some(213),
8188 concrete: true,
8189 origins: &["DY"],
8190 comment: "Pitch control power model. Reference: IEC 61400-27-1:2015, 5.6.5.1.",
8191 attrs: &[
8192 AttrDef { id: "WindPitchContPowerIEC.WindDynamicsLookupTable", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindDynamicsLookupTable", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "The wind dynamics lookup table associated with this pitch control power model." },
8193 AttrDef { id: "WindPitchContPowerIEC.WindGenTurbineType1bIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindGenTurbineType1bIEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 1B model with which this pitch control power model is associated." },
8194 AttrDef { id: "WindPitchContPowerIEC.WindGenTurbineType2IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindGenTurbineType2IEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 2 model with which this pitch control power model is associated." },
8195 AttrDef { id: "WindPitchContPowerIEC.dpmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rate limit for increasing power (dpmax) (> WindPitchContPowerIEC.dpmin). It is a type-dependent parameter." },
8196 AttrDef { id: "WindPitchContPowerIEC.dpmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Rate limit for decreasing power (dpmin) (< WindPitchContPowerIEC.dpmax). It is a type-dependent parameter." },
8197 AttrDef { id: "WindPitchContPowerIEC.pmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum power setting (pmin). It is a type-dependent parameter." },
8198 AttrDef { id: "WindPitchContPowerIEC.pset", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "If pinit < pset then power will be ramped down to pmin. It is (pset) in the IEC 61400-27-1:2015. It is a type-dependent parameter." },
8199 AttrDef { id: "WindPitchContPowerIEC.t1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant (T1) (>= 0). It is a type-dependent parameter." },
8200 AttrDef { id: "WindPitchContPowerIEC.tr", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage measurement time constant (Tr) (>= 0). It is a type-dependent parameter." },
8201 AttrDef { id: "WindPitchContPowerIEC.uuvrt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Dip detection threshold (uUVRT). It is a type-dependent parameter." },
8202 ],
8203 },
8204 ClassDef {
8205 ns: "http://iec.ch/TC57/CIM100#",
8206 local: "WindPlantDynamics",
8207 qualified: "WindPlantDynamics",
8208 super_class: Some(91),
8209 concrete: false,
8210 origins: &["DY"],
8211 comment: "Parent class supporting relationships to wind turbines type 3 and type 4 and wind plant IEC and user-defined wind plants including their control models.",
8212 attrs: &[
8213 AttrDef { id: "WindPlantDynamics.RemoteInputSignal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RemoteInputSignal", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "The remote signal with which this power plant is associated." },
8214 AttrDef { id: "WindPlantDynamics.WindTurbineType3or4Dynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType3or4Dynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "The wind turbine type 3 or type 4 associated with this wind plant." },
8215 ],
8216 },
8217 ClassDef {
8218 ns: "http://iec.ch/TC57/CIM100#",
8219 local: "WindPlantFreqPcontrolIEC",
8220 qualified: "WindPlantFreqPcontrolIEC",
8221 super_class: Some(213),
8222 concrete: true,
8223 origins: &["DY"],
8224 comment: "Frequency and active power controller model. Reference: IEC 61400-27-1:2015, Annex D.",
8225 attrs: &[
8226 AttrDef { id: "WindPlantFreqPcontrolIEC.WindDynamicsLookupTable", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindDynamicsLookupTable", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "The wind dynamics lookup table associated with this frequency and active power wind plant model." },
8227 AttrDef { id: "WindPlantFreqPcontrolIEC.WindPlantIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindPlantIEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind plant model with which this wind plant frequency and active power control is associated." },
8228 AttrDef { id: "WindPlantFreqPcontrolIEC.dprefmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum ramp rate of pWTref request from the plant controller to the wind turbines (dprefmax) (> WindPlantFreqPcontrolIEC.dprefmin). It is a case-dependent parameter." },
8229 AttrDef { id: "WindPlantFreqPcontrolIEC.dprefmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum (negative) ramp rate of pWTref request from the plant controller to the wind turbines (dprefmin) (< WindPlantFreqPcontrolIEC.dprefmax). It is a project-dependent parameter." },
8230 AttrDef { id: "WindPlantFreqPcontrolIEC.dpwprefmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum positive ramp rate for wind plant power reference (dpWPrefmax) (> WindPlantFreqPcontrolIEC.dpwprefmin). It is a project-dependent parameter." },
8231 AttrDef { id: "WindPlantFreqPcontrolIEC.dpwprefmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum negative ramp rate for wind plant power reference (dpWPrefmin) (< WindPlantFreqPcontrolIEC.dpwprefmax). It is a project-dependent parameter." },
8232 AttrDef { id: "WindPlantFreqPcontrolIEC.kiwpp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Plant P controller integral gain (KIWPp). It is a project-dependent parameter." },
8233 AttrDef { id: "WindPlantFreqPcontrolIEC.kiwppmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum PI integrator term (KIWPpmax) (> WindPlantFreqPcontrolIEC.kiwppmin). It is a project-dependent parameter." },
8234 AttrDef { id: "WindPlantFreqPcontrolIEC.kiwppmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum PI integrator term (KIWPpmin) (< WindPlantFreqPcontrolIEC.kiwppmax). It is a project-dependent parameter." },
8235 AttrDef { id: "WindPlantFreqPcontrolIEC.kpwpp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Plant P controller proportional gain (KPWPp). It is a project-dependent parameter." },
8236 AttrDef { id: "WindPlantFreqPcontrolIEC.kwppref", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Power reference gain (KWPpref). It is a project-dependent parameter." },
8237 AttrDef { id: "WindPlantFreqPcontrolIEC.prefmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum pWTref request from the plant controller to the wind turbines (prefmax) (> WindPlantFreqPcontrolIEC.prefmin). It is a project-dependent parameter." },
8238 AttrDef { id: "WindPlantFreqPcontrolIEC.prefmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum pWTref request from the plant controller to the wind turbines (prefmin) (< WindPlantFreqPcontrolIEC.prefmax). It is a project-dependent parameter." },
8239 AttrDef { id: "WindPlantFreqPcontrolIEC.tpft", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead time constant in reference value transfer function (Tpft) (>= 0). It is a project-dependent parameter." },
8240 AttrDef { id: "WindPlantFreqPcontrolIEC.tpfv", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant in reference value transfer function (Tpfv) (>= 0). It is a project-dependent parameter." },
8241 AttrDef { id: "WindPlantFreqPcontrolIEC.twpffiltp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter time constant for frequency measurement (TWPffiltp) (>= 0). It is a project-dependent parameter." },
8242 AttrDef { id: "WindPlantFreqPcontrolIEC.twppfiltp", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter time constant for active power measurement (TWPpfiltp) (>= 0). It is a project-dependent parameter." },
8243 ],
8244 },
8245 ClassDef {
8246 ns: "http://iec.ch/TC57/CIM100#",
8247 local: "WindPlantIEC",
8248 qualified: "WindPlantIEC",
8249 super_class: Some(427),
8250 concrete: true,
8251 origins: &["DY"],
8252 comment: "Simplified IEC type plant level model. Reference: IEC 61400-27-1:2015, Annex D.",
8253 attrs: &[
8254 AttrDef { id: "WindPlantIEC.WindPlantFreqPcontrolIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindPlantFreqPcontrolIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind plant frequency and active power control model associated with this wind plant." },
8255 AttrDef { id: "WindPlantIEC.WindPlantReactiveControlIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindPlantReactiveControlIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind plant model with which this wind reactive control is associated." },
8256 ],
8257 },
8258 ClassDef {
8259 ns: "http://iec.ch/TC57/CIM100#",
8260 local: "WindPlantReactiveControlIEC",
8261 qualified: "WindPlantReactiveControlIEC",
8262 super_class: Some(213),
8263 concrete: true,
8264 origins: &["DY"],
8265 comment: "Simplified plant voltage and reactive power control model for use with type 3 and type 4 wind turbine models. Reference: IEC 61400-27-1:2015, Annex D.",
8266 attrs: &[
8267 AttrDef { id: "WindPlantReactiveControlIEC.WindDynamicsLookupTable", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindDynamicsLookupTable", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "The wind dynamics lookup table associated with this voltage and reactive power wind plant model." },
8268 AttrDef { id: "WindPlantReactiveControlIEC.WindPlantIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindPlantIEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind plant reactive control model associated with this wind plant." },
8269 AttrDef { id: "WindPlantReactiveControlIEC.dxrefmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum positive ramp rate for wind turbine reactive power/voltage reference (dxrefmax) (> WindPlantReactiveControlIEC.dxrefmin). It is a project-dependent parameter." },
8270 AttrDef { id: "WindPlantReactiveControlIEC.dxrefmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum negative ramp rate for wind turbine reactive power/voltage reference (dxrefmin) (< WindPlantReactiveControlIEC.dxrefmax). It is a project-dependent parameter." },
8271 AttrDef { id: "WindPlantReactiveControlIEC.kiwpx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Plant Q controller integral gain (KIWPx). It is a project-dependent parameter." },
8272 AttrDef { id: "WindPlantReactiveControlIEC.kiwpxmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum reactive power/voltage reference from integration (KIWPxmax) (> WindPlantReactiveControlIEC.kiwpxmin). It is a project-dependent parameter." },
8273 AttrDef { id: "WindPlantReactiveControlIEC.kiwpxmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum reactive power/voltage reference from integration (KIWPxmin) (< WindPlantReactiveControlIEC.kiwpxmax). It is a project-dependent parameter." },
8274 AttrDef { id: "WindPlantReactiveControlIEC.kpwpx", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Float", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Plant Q controller proportional gain (KPWPx). It is a project-dependent parameter." },
8275 AttrDef { id: "WindPlantReactiveControlIEC.kwpqref", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Reactive power reference gain (KWPqref). It is a project-dependent parameter." },
8276 AttrDef { id: "WindPlantReactiveControlIEC.kwpqu", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Plant voltage control droop (KWPqu). It is a project-dependent parameter." },
8277 AttrDef { id: "WindPlantReactiveControlIEC.tuqfilt", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter time constant for voltage-dependent reactive power (Tuqfilt) (>= 0). It is a project-dependent parameter." },
8278 AttrDef { id: "WindPlantReactiveControlIEC.twppfiltq", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter time constant for active power measurement (TWPpfiltq) (>= 0). It is a project-dependent parameter." },
8279 AttrDef { id: "WindPlantReactiveControlIEC.twpqfiltq", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter time constant for reactive power measurement (TWPqfiltq) (>= 0). It is a project-dependent parameter." },
8280 AttrDef { id: "WindPlantReactiveControlIEC.twpufiltq", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Filter time constant for voltage measurement (TWPufiltq) (>= 0). It is a project-dependent parameter." },
8281 AttrDef { id: "WindPlantReactiveControlIEC.txft", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lead time constant in reference value transfer function (Txft) (>= 0). It is a project-dependent parameter." },
8282 AttrDef { id: "WindPlantReactiveControlIEC.txfv", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Lag time constant in reference value transfer function (Txfv) (>= 0). It is a project-dependent parameter." },
8283 AttrDef { id: "WindPlantReactiveControlIEC.uwpqdip", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage threshold for UVRT detection in Q control (uWPqdip). It is a project-dependent parameter." },
8284 AttrDef { id: "WindPlantReactiveControlIEC.windPlantQcontrolModesType", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Enum, range: "WindPlantQcontrolModeKind", is_list: false, used: true, xsd: "", value_ns: "http://iec.ch/TC57/CIM100#", origins: &["DY"], comment: "Reactive power/voltage controller mode (MWPqmode). It is a case-dependent parameter." },
8285 AttrDef { id: "WindPlantReactiveControlIEC.xrefmax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum xWTref (qWTref or delta uWTref) request from the plant controller (xrefmax) (> WindPlantReactiveControlIEC.xrefmin). It is a case-dependent parameter." },
8286 AttrDef { id: "WindPlantReactiveControlIEC.xrefmin", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Minimum xWTref (qWTref or delta uWTref) request from the plant controller (xrefmin) (< WindPlantReactiveControlIEC.xrefmax). It is a project-dependent parameter." },
8287 ],
8288 },
8289 ClassDef {
8290 ns: "http://iec.ch/TC57/CIM100#",
8291 local: "WindPlantUserDefined",
8292 qualified: "WindPlantUserDefined",
8293 super_class: Some(427),
8294 concrete: true,
8295 origins: &["DY"],
8296 comment: "Wind plant function block whose dynamic behaviour is described by a user-defined model.",
8297 attrs: &[
8298 AttrDef { id: "WindPlantUserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
8299 AttrDef { id: "WindPlantUserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
8300 ],
8301 },
8302 ClassDef {
8303 ns: "http://iec.ch/TC57/CIM100-European#",
8304 local: "WindPowerPlant",
8305 qualified: "WindPowerPlant",
8306 super_class: Some(282),
8307 concrete: true,
8308 origins: &["EQ"],
8309 comment: "Wind power plant.",
8310 attrs: &[
8311 AttrDef { id: "WindPowerPlant.WindGeneratingUnits", ns: "http://iec.ch/TC57/CIM100-European#", kind: AttrKind::Association, range: "WindGeneratingUnit", is_list: true, used: false, xsd: "", value_ns: "", origins: &["EQ"], comment: "A wind generating unit or units may be a member of a wind power plant." },
8312 ],
8313 },
8314 ClassDef {
8315 ns: "http://iec.ch/TC57/CIM100#",
8316 local: "WindProtectionIEC",
8317 qualified: "WindProtectionIEC",
8318 super_class: Some(213),
8319 concrete: true,
8320 origins: &["DY"],
8321 comment: "The grid protection model includes protection against over- and under-voltage, and against over- and under-frequency. Reference: IEC 61400-27-1:2015, 5.6.6.",
8322 attrs: &[
8323 AttrDef { id: "WindProtectionIEC.WindDynamicsLookupTable", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindDynamicsLookupTable", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "The wind dynamics lookup table associated with this grid protection model." },
8324 AttrDef { id: "WindProtectionIEC.WindTurbineType1or2IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType1or2IEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind generator type 1 or type 2 model with which this wind turbine protection model is associated." },
8325 AttrDef { id: "WindProtectionIEC.WindTurbineType3or4IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType3or4IEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind generator type 3 or type 4 model with which this wind turbine protection model is associated." },
8326 AttrDef { id: "WindProtectionIEC.dfimax", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Maximum rate of change of frequency (dFmax). It is a type-dependent parameter." },
8327 AttrDef { id: "WindProtectionIEC.fover", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Wind turbine over frequency protection activation threshold (fover). It is a project-dependent parameter." },
8328 AttrDef { id: "WindProtectionIEC.funder", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Wind turbine under frequency protection activation threshold (funder). It is a project-dependent parameter." },
8329 AttrDef { id: "WindProtectionIEC.mzc", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Zero crossing measurement mode (Mzc). It is a type-dependent parameter. true = WT protection system uses zero crossings to detect frequency (1 in the IEC model) false = WT protection system does not use zero crossings to detect frequency (0 in the IEC model)." },
8330 AttrDef { id: "WindProtectionIEC.tfma", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time interval of moving average window (TfMA) (>= 0). It is a type-dependent parameter." },
8331 AttrDef { id: "WindProtectionIEC.uover", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Wind turbine over voltage protection activation threshold (uover). It is a project-dependent parameter." },
8332 AttrDef { id: "WindProtectionIEC.uunder", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Wind turbine under voltage protection activation threshold (uunder). It is a project-dependent parameter." },
8333 ],
8334 },
8335 ClassDef {
8336 ns: "http://iec.ch/TC57/CIM100#",
8337 local: "WindRefFrameRotIEC",
8338 qualified: "WindRefFrameRotIEC",
8339 super_class: Some(213),
8340 concrete: true,
8341 origins: &["DY"],
8342 comment: "Reference frame rotation model. Reference: IEC 61400-27-1:2015, 5.6.3.5.",
8343 attrs: &[
8344 AttrDef { id: "WindRefFrameRotIEC.WindTurbineType3or4IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindTurbineType3or4IEC", is_list: false, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbine type 3 or type 4 model with which this reference frame rotation model is associated." },
8345 AttrDef { id: "WindRefFrameRotIEC.tpll", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Seconds", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Time constant for PLL first order filter model (TPLL) (>= 0). It is a type-dependent parameter." },
8346 AttrDef { id: "WindRefFrameRotIEC.upll1", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage below which the angle of the voltage is filtered and possibly also frozen (uPLL1). It is a type-dependent parameter." },
8347 AttrDef { id: "WindRefFrameRotIEC.upll2", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "PU", is_list: false, used: true, xsd: "double", value_ns: "", origins: &["DY"], comment: "Voltage (uPLL2) below which the angle of the voltage is frozen if uPLL2 is smaller or equal to uPLL1 . It is a type-dependent parameter." },
8348 ],
8349 },
8350 ClassDef {
8351 ns: "http://iec.ch/TC57/CIM100#",
8352 local: "WindTurbineType1or2Dynamics",
8353 qualified: "WindTurbineType1or2Dynamics",
8354 super_class: Some(91),
8355 concrete: false,
8356 origins: &["DY"],
8357 comment: "Parent class supporting relationships to wind turbines type 1 and type 2 and their control models. Generator model for wind turbine of type 1 or type 2 is a standard asynchronous generator model.",
8358 attrs: &[
8359 AttrDef { id: "WindTurbineType1or2Dynamics.AsynchronousMachineDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "AsynchronousMachineDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Asynchronous machine model with which this wind generator type 1 or type 2 model is associated." },
8360 AttrDef { id: "WindTurbineType1or2Dynamics.RemoteInputSignal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RemoteInputSignal", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Remote input signal used by this wind generator type 1 or type 2 model." },
8361 ],
8362 },
8363 ClassDef {
8364 ns: "http://iec.ch/TC57/CIM100#",
8365 local: "WindTurbineType1or2IEC",
8366 qualified: "WindTurbineType1or2IEC",
8367 super_class: Some(435),
8368 concrete: false,
8369 origins: &["DY"],
8370 comment: "Parent class supporting relationships to IEC wind turbines type 1 and type 2 including their control models. Generator model for wind turbine of IEC type 1 or type 2 is a standard asynchronous generator model. Reference: IEC 61400-27-1:2015, 5.5.2 and 5.5.3.",
8371 attrs: &[
8372 AttrDef { id: "WindTurbineType1or2IEC.WindMechIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindMechIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind mechanical model associated with this wind generator type 1 or type 2 model." },
8373 AttrDef { id: "WindTurbineType1or2IEC.WindProtectionIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindProtectionIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbune protection model associated with this wind generator type 1 or type 2 model." },
8374 ],
8375 },
8376 ClassDef {
8377 ns: "http://iec.ch/TC57/CIM100#",
8378 local: "WindTurbineType3IEC",
8379 qualified: "WindTurbineType3IEC",
8380 super_class: Some(439),
8381 concrete: true,
8382 origins: &["DY"],
8383 comment: "Parent class supporting relationships to IEC wind turbines type 3 including their control models.",
8384 attrs: &[
8385 AttrDef { id: "WindTurbineType3IEC.WindAeroOneDimIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindAeroOneDimIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind aerodynamic model associated with this wind generator type 3 model." },
8386 AttrDef { id: "WindTurbineType3IEC.WindAeroTwoDimIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindAeroTwoDimIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind aerodynamic model associated with this wind turbine type 3 model." },
8387 AttrDef { id: "WindTurbineType3IEC.WindContPType3IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindContPType3IEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind control P type 3 model associated with this wind turbine type 3 model." },
8388 AttrDef { id: "WindTurbineType3IEC.WindContPitchAngleIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindContPitchAngleIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind control pitch angle model associated with this wind turbine type 3." },
8389 AttrDef { id: "WindTurbineType3IEC.WindGenType3IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindGenType3IEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind generator type 3 model associated with this wind turbine type 3 model." },
8390 AttrDef { id: "WindTurbineType3IEC.WindMechIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindMechIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind mechanical model associated with this wind turbine type 3 model." },
8391 ],
8392 },
8393 ClassDef {
8394 ns: "http://iec.ch/TC57/CIM100#",
8395 local: "WindTurbineType3or4Dynamics",
8396 qualified: "WindTurbineType3or4Dynamics",
8397 super_class: Some(91),
8398 concrete: false,
8399 origins: &["DY"],
8400 comment: "Parent class supporting relationships to wind turbines type 3 and type 4 and wind plant including their control models.",
8401 attrs: &[
8402 AttrDef { id: "WindTurbineType3or4Dynamics.PowerElectronicsConnection", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "PowerElectronicsConnection", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "The power electronics connection associated with this wind turbine type 3 or type 4 dynamics model." },
8403 AttrDef { id: "WindTurbineType3or4Dynamics.RemoteInputSignal", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "RemoteInputSignal", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Remote input signal used by these wind turbine type 3 or type 4 models." },
8404 AttrDef { id: "WindTurbineType3or4Dynamics.WindPlantDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindPlantDynamics", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "The wind plant with which the wind turbines type 3 or type 4 are associated." },
8405 ],
8406 },
8407 ClassDef {
8408 ns: "http://iec.ch/TC57/CIM100#",
8409 local: "WindTurbineType3or4IEC",
8410 qualified: "WindTurbineType3or4IEC",
8411 super_class: Some(438),
8412 concrete: false,
8413 origins: &["DY"],
8414 comment: "Parent class supporting relationships to IEC wind turbines type 3 and type 4 including their control models.",
8415 attrs: &[
8416 AttrDef { id: "WindTurbineType3or4IEC.WIndContQIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindContQIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind control Q model associated with this wind turbine type 3 or type 4 model." },
8417 AttrDef { id: "WindTurbineType3or4IEC.WindContCurrLimIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindContCurrLimIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind control current limitation model associated with this wind turbine type 3 or type 4 model." },
8418 AttrDef { id: "WindTurbineType3or4IEC.WindContQLimIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindContQLimIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Constant Q limitation model associated with this wind generator type 3 or type 4 model." },
8419 AttrDef { id: "WindTurbineType3or4IEC.WindContQPQULimIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindContQPQULimIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "QP and QU limitation model associated with this wind generator type 3 or type 4 model." },
8420 AttrDef { id: "WindTurbineType3or4IEC.WindProtectionIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindProtectionIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind turbune protection model associated with this wind generator type 3 or type 4 model." },
8421 AttrDef { id: "WindTurbineType3or4IEC.WindRefFrameRotIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindRefFrameRotIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Reference frame rotation model associated with this wind turbine type 3 or type 4 model." },
8422 ],
8423 },
8424 ClassDef {
8425 ns: "http://iec.ch/TC57/CIM100#",
8426 local: "WindTurbineType4IEC",
8427 qualified: "WindTurbineType4IEC",
8428 super_class: Some(439),
8429 concrete: false,
8430 origins: &["DY"],
8431 comment: "Parent class supporting relationships to IEC wind turbines type 4 including their control models.",
8432 attrs: &[
8433 AttrDef { id: "WindTurbineType4IEC.WindGenType3aIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindGenType3aIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind generator type 3A model associated with this wind turbine type 4 model." },
8434 ],
8435 },
8436 ClassDef {
8437 ns: "http://iec.ch/TC57/CIM100#",
8438 local: "WindTurbineType4aIEC",
8439 qualified: "WindTurbineType4aIEC",
8440 super_class: Some(440),
8441 concrete: true,
8442 origins: &["DY"],
8443 comment: "Wind turbine IEC type 4A. Reference: IEC 61400-27-1:2015, 5.5.5.2.",
8444 attrs: &[
8445 AttrDef { id: "WindTurbineType4aIEC.WindContPType4aIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindContPType4aIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind control P type 4A model associated with this wind turbine type 4A model." },
8446 AttrDef { id: "WindTurbineType4aIEC.WindGenType4IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindGenType4IEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind generator type 4 model associated with this wind turbine type 4A model." },
8447 ],
8448 },
8449 ClassDef {
8450 ns: "http://iec.ch/TC57/CIM100#",
8451 local: "WindTurbineType4bIEC",
8452 qualified: "WindTurbineType4bIEC",
8453 super_class: Some(440),
8454 concrete: true,
8455 origins: &["DY"],
8456 comment: "Wind turbine IEC type 4B. Reference: IEC 61400-27-1:2015, 5.5.5.3.",
8457 attrs: &[
8458 AttrDef { id: "WindTurbineType4bIEC.WindContPType4bIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindContPType4bIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind control P type 4B model associated with this wind turbine type 4B model." },
8459 AttrDef { id: "WindTurbineType4bIEC.WindGenType4IEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindGenType4IEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind generator type 4 model associated with this wind turbine type 4B model." },
8460 AttrDef { id: "WindTurbineType4bIEC.WindMechIEC", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "WindMechIEC", is_list: false, used: true, xsd: "", value_ns: "", origins: &["DY"], comment: "Wind mechanical model associated with this wind turbine type 4B model." },
8461 ],
8462 },
8463 ClassDef {
8464 ns: "http://iec.ch/TC57/CIM100#",
8465 local: "WindType1or2UserDefined",
8466 qualified: "WindType1or2UserDefined",
8467 super_class: Some(435),
8468 concrete: true,
8469 origins: &["DY"],
8470 comment: "Wind type 1 or type 2 function block whose dynamic behaviour is described by a user-defined model.",
8471 attrs: &[
8472 AttrDef { id: "WindType1or2UserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
8473 AttrDef { id: "WindType1or2UserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
8474 ],
8475 },
8476 ClassDef {
8477 ns: "http://iec.ch/TC57/CIM100#",
8478 local: "WindType3or4UserDefined",
8479 qualified: "WindType3or4UserDefined",
8480 super_class: Some(438),
8481 concrete: true,
8482 origins: &["DY"],
8483 comment: "Wind type 3 or type 4 function block whose dynamic behaviour is described by a user-defined model.",
8484 attrs: &[
8485 AttrDef { id: "WindType3or4UserDefined.ProprietaryParameterDynamics", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Association, range: "ProprietaryParameterDynamics", is_list: true, used: false, xsd: "", value_ns: "", origins: &["DY"], comment: "Parameter of this proprietary user-defined model." },
8486 AttrDef { id: "WindType3or4UserDefined.proprietary", ns: "http://iec.ch/TC57/CIM100#", kind: AttrKind::Literal, range: "Boolean", is_list: false, used: true, xsd: "boolean", value_ns: "", origins: &["DY"], comment: "Behaviour is based on a proprietary model as opposed to a detailed model. true = user-defined model is proprietary with behaviour mutually understood by sending and receiving applications and parameters passed as general attributes false = user-defined model is explicitly defined in terms of control blocks and their input and output signals." },
8487 ],
8488 },
8489 ClassDef {
8490 ns: "http://iec.ch/TC57/CIM100#",
8491 local: "WorkLocation",
8492 qualified: "WorkLocation",
8493 super_class: Some(232),
8494 concrete: false,
8495 origins: &["GL"],
8496 comment: "Information about a particular location for various forms of work.",
8497 attrs: &[],
8498 },
8499];
8500
8501pub static PROFILES: &[(&str, &str)] = &[
8503 ("DL", "http://iec.ch/TC57/ns/CIM/DiagramLayout-EU/3.0"),
8504 ("DY", "http://iec.ch/TC57/ns/CIM/Dynamics-EU/1.0"),
8505 ("EQ", "http://iec.ch/TC57/ns/CIM/CoreEquipment-EU/3.0"),
8506 ("EQBD", "http://iec.ch/TC57/ns/CIM/EquipmentBoundary-EU/3.0"),
8507 ("FH", "http://iec.ch/TC57/61970-552/ModelDescription/1"),
8508 ("GL", "http://iec.ch/TC57/ns/CIM/GeographicalLocation-EU/3.0"),
8509 ("OP", "http://iec.ch/TC57/ns/CIM/Operation-EU/3.0"),
8510 ("SC", "http://iec.ch/TC57/ns/CIM/ShortCircuit-EU/3.0"),
8511 ("SSH", "http://iec.ch/TC57/ns/CIM/SteadyStateHypothesis-EU/3.0"),
8512 ("SV", "http://iec.ch/TC57/ns/CIM/StateVariables-EU/3.0"),
8513 ("TP", "http://iec.ch/TC57/ns/CIM/Topology-EU/3.0"),
8514];
8515
8516pub static NAMESPACES: &[(&str, &str)] = &[
8518 ("cim", "http://iec.ch/TC57/CIM100#"),
8519 ("dm", "http://iec.ch/TC57/61970-552/DifferenceModel/1#"),
8520 ("eu", "http://iec.ch/TC57/CIM100-European#"),
8521 ("md", "http://iec.ch/TC57/61970-552/ModelDescription/1#"),
8522 ("rdf", "http://www.w3.org/1999/02/22-rdf-syntax-ns#"),
8523];
8524
8525pub static ENUMS: &[EnumDef] = &[
8527 EnumDef {
8528 ns: "http://iec.ch/TC57/CIM100#",
8529 local: "AsynchronousMachineKind",
8530 comment: "Kind of Asynchronous Machine.",
8531 values: &[
8532 EnumValueDef { id: "AsynchronousMachineKind.generator", comment: "The Asynchronous Machine is a generator." },
8533 EnumValueDef { id: "AsynchronousMachineKind.motor", comment: "The Asynchronous Machine is a motor." },
8534 ],
8535 },
8536 EnumDef {
8537 ns: "http://iec.ch/TC57/CIM100#",
8538 local: "BatteryStateKind",
8539 comment: "The state of the battery unit.",
8540 values: &[
8541 EnumValueDef { id: "BatteryStateKind.discharging", comment: "Stored energy is decreasing." },
8542 EnumValueDef { id: "BatteryStateKind.full", comment: "Unable to charge, and not discharging." },
8543 EnumValueDef { id: "BatteryStateKind.waiting", comment: "Neither charging nor discharging, but able to do so." },
8544 EnumValueDef { id: "BatteryStateKind.charging", comment: "Stored energy is increasing." },
8545 EnumValueDef { id: "BatteryStateKind.empty", comment: "Unable to discharge, and not charging." },
8546 ],
8547 },
8548 EnumDef {
8549 ns: "http://iec.ch/TC57/CIM100#",
8550 local: "ControlAreaTypeKind",
8551 comment: "The type of control area.",
8552 values: &[
8553 EnumValueDef { id: "ControlAreaTypeKind.AGC", comment: "Used for automatic generation control." },
8554 EnumValueDef { id: "ControlAreaTypeKind.Forecast", comment: "Used for load forecast." },
8555 EnumValueDef { id: "ControlAreaTypeKind.Interchange", comment: "Used for interchange specification or control." },
8556 ],
8557 },
8558 EnumDef {
8559 ns: "http://iec.ch/TC57/CIM100#",
8560 local: "CsOperatingModeKind",
8561 comment: "Operating mode for HVDC line operating as Current Source Converter.",
8562 values: &[
8563 EnumValueDef { id: "CsOperatingModeKind.inverter", comment: "Operating as inverter, which is the power receiving end." },
8564 EnumValueDef { id: "CsOperatingModeKind.rectifier", comment: "Operating as rectifier, which is the power sending end." },
8565 ],
8566 },
8567 EnumDef {
8568 ns: "http://iec.ch/TC57/CIM100#",
8569 local: "CsPpccControlKind",
8570 comment: "Active power control modes for HVDC line operating as Current Source Converter.",
8571 values: &[
8572 EnumValueDef { id: "CsPpccControlKind.activePower", comment: "Control is active power control at AC side, at point of common coupling. Target is provided by ACDCConverter.targetPpcc." },
8573 EnumValueDef { id: "CsPpccControlKind.dcVoltage", comment: "Control is DC voltage with target value provided by ACDCConverter.targetUdc." },
8574 EnumValueDef { id: "CsPpccControlKind.dcCurrent", comment: "Control is DC current with target value provided by CsConverter.targetIdc." },
8575 ],
8576 },
8577 EnumDef {
8578 ns: "http://iec.ch/TC57/CIM100#",
8579 local: "Currency",
8580 comment: "Monetary currencies. ISO 4217 standard including 3-character currency code.",
8581 values: &[
8582 EnumValueDef { id: "Currency.AED", comment: "United Arab Emirates dirham." },
8583 EnumValueDef { id: "Currency.AFN", comment: "Afghan afghani." },
8584 EnumValueDef { id: "Currency.ALL", comment: "Albanian lek." },
8585 EnumValueDef { id: "Currency.AMD", comment: "Armenian dram." },
8586 EnumValueDef { id: "Currency.ANG", comment: "Netherlands Antillean guilder." },
8587 EnumValueDef { id: "Currency.AOA", comment: "Angolan kwanza." },
8588 EnumValueDef { id: "Currency.ARS", comment: "Argentine peso." },
8589 EnumValueDef { id: "Currency.AUD", comment: "Australian dollar." },
8590 EnumValueDef { id: "Currency.AWG", comment: "Aruban florin." },
8591 EnumValueDef { id: "Currency.AZN", comment: "Azerbaijani manat." },
8592 EnumValueDef { id: "Currency.BAM", comment: "Bosnia and Herzegovina convertible mark." },
8593 EnumValueDef { id: "Currency.BBD", comment: "Barbados dollar." },
8594 EnumValueDef { id: "Currency.BDT", comment: "Bangladeshi taka." },
8595 EnumValueDef { id: "Currency.BGN", comment: "Bulgarian lev." },
8596 EnumValueDef { id: "Currency.BHD", comment: "Bahraini dinar." },
8597 EnumValueDef { id: "Currency.BIF", comment: "Burundian franc." },
8598 EnumValueDef { id: "Currency.BMD", comment: "Bermudian dollar (customarily known as Bermuda dollar)." },
8599 EnumValueDef { id: "Currency.BND", comment: "Brunei dollar." },
8600 EnumValueDef { id: "Currency.BOB", comment: "Boliviano." },
8601 EnumValueDef { id: "Currency.BOV", comment: "Bolivian Mvdol (funds code)." },
8602 EnumValueDef { id: "Currency.BRL", comment: "Brazilian real." },
8603 EnumValueDef { id: "Currency.BSD", comment: "Bahamian dollar." },
8604 EnumValueDef { id: "Currency.BTN", comment: "Bhutanese ngultrum." },
8605 EnumValueDef { id: "Currency.BWP", comment: "Botswana pula." },
8606 EnumValueDef { id: "Currency.BYR", comment: "Belarusian ruble." },
8607 EnumValueDef { id: "Currency.BZD", comment: "Belize dollar." },
8608 EnumValueDef { id: "Currency.CAD", comment: "Canadian dollar." },
8609 EnumValueDef { id: "Currency.CDF", comment: "Congolese franc." },
8610 EnumValueDef { id: "Currency.CHF", comment: "Swiss franc." },
8611 EnumValueDef { id: "Currency.CLF", comment: "Unidad de Fomento (funds code), Chile." },
8612 EnumValueDef { id: "Currency.CLP", comment: "Chilean peso." },
8613 EnumValueDef { id: "Currency.CNY", comment: "Chinese yuan." },
8614 EnumValueDef { id: "Currency.COP", comment: "Colombian peso." },
8615 EnumValueDef { id: "Currency.COU", comment: "Unidad de Valor Real." },
8616 EnumValueDef { id: "Currency.CRC", comment: "Costa Rican colon." },
8617 EnumValueDef { id: "Currency.CUC", comment: "Cuban convertible peso." },
8618 EnumValueDef { id: "Currency.CUP", comment: "Cuban peso." },
8619 EnumValueDef { id: "Currency.CVE", comment: "Cape Verde escudo." },
8620 EnumValueDef { id: "Currency.CZK", comment: "Czech koruna." },
8621 EnumValueDef { id: "Currency.DJF", comment: "Djiboutian franc." },
8622 EnumValueDef { id: "Currency.DKK", comment: "Danish krone." },
8623 EnumValueDef { id: "Currency.DOP", comment: "Dominican peso." },
8624 EnumValueDef { id: "Currency.DZD", comment: "Algerian dinar." },
8625 EnumValueDef { id: "Currency.EEK", comment: "Estonian kroon." },
8626 EnumValueDef { id: "Currency.EGP", comment: "Egyptian pound." },
8627 EnumValueDef { id: "Currency.ERN", comment: "Eritrean nakfa." },
8628 EnumValueDef { id: "Currency.ETB", comment: "Ethiopian birr." },
8629 EnumValueDef { id: "Currency.EUR", comment: "Euro." },
8630 EnumValueDef { id: "Currency.FJD", comment: "Fiji dollar." },
8631 EnumValueDef { id: "Currency.FKP", comment: "Falkland Islands pound." },
8632 EnumValueDef { id: "Currency.GBP", comment: "Pound sterling." },
8633 EnumValueDef { id: "Currency.GEL", comment: "Georgian lari." },
8634 EnumValueDef { id: "Currency.GHS", comment: "Ghanaian cedi." },
8635 EnumValueDef { id: "Currency.GIP", comment: "Gibraltar pound." },
8636 EnumValueDef { id: "Currency.GMD", comment: "Gambian dalasi." },
8637 EnumValueDef { id: "Currency.GNF", comment: "Guinean franc." },
8638 EnumValueDef { id: "Currency.GTQ", comment: "Guatemalan quetzal." },
8639 EnumValueDef { id: "Currency.GYD", comment: "Guyanese dollar." },
8640 EnumValueDef { id: "Currency.HKD", comment: "Hong Kong dollar." },
8641 EnumValueDef { id: "Currency.HNL", comment: "Honduran lempira." },
8642 EnumValueDef { id: "Currency.HRK", comment: "Croatian kuna." },
8643 EnumValueDef { id: "Currency.HTG", comment: "Haitian gourde." },
8644 EnumValueDef { id: "Currency.HUF", comment: "Hungarian forint." },
8645 EnumValueDef { id: "Currency.IDR", comment: "Indonesian rupiah." },
8646 EnumValueDef { id: "Currency.ILS", comment: "Israeli new sheqel." },
8647 EnumValueDef { id: "Currency.INR", comment: "Indian rupee." },
8648 EnumValueDef { id: "Currency.IQD", comment: "Iraqi dinar." },
8649 EnumValueDef { id: "Currency.IRR", comment: "Iranian rial." },
8650 EnumValueDef { id: "Currency.ISK", comment: "Icelandic króna." },
8651 EnumValueDef { id: "Currency.JMD", comment: "Jamaican dollar." },
8652 EnumValueDef { id: "Currency.JOD", comment: "Jordanian dinar." },
8653 EnumValueDef { id: "Currency.JPY", comment: "Japanese yen." },
8654 EnumValueDef { id: "Currency.KES", comment: "Kenyan shilling." },
8655 EnumValueDef { id: "Currency.KGS", comment: "Kyrgyzstani som." },
8656 EnumValueDef { id: "Currency.KHR", comment: "Cambodian riel." },
8657 EnumValueDef { id: "Currency.KMF", comment: "Comoro franc." },
8658 EnumValueDef { id: "Currency.KPW", comment: "North Korean won." },
8659 EnumValueDef { id: "Currency.KRW", comment: "South Korean won." },
8660 EnumValueDef { id: "Currency.KWD", comment: "Kuwaiti dinar." },
8661 EnumValueDef { id: "Currency.KYD", comment: "Cayman Islands dollar." },
8662 EnumValueDef { id: "Currency.KZT", comment: "Kazakhstani tenge." },
8663 EnumValueDef { id: "Currency.LAK", comment: "Lao kip." },
8664 EnumValueDef { id: "Currency.LBP", comment: "Lebanese pound." },
8665 EnumValueDef { id: "Currency.LKR", comment: "Sri Lanka rupee." },
8666 EnumValueDef { id: "Currency.LRD", comment: "Liberian dollar." },
8667 EnumValueDef { id: "Currency.LSL", comment: "Lesotho loti." },
8668 EnumValueDef { id: "Currency.LTL", comment: "Lithuanian litas." },
8669 EnumValueDef { id: "Currency.LVL", comment: "Latvian lats." },
8670 EnumValueDef { id: "Currency.LYD", comment: "Libyan dinar." },
8671 EnumValueDef { id: "Currency.MAD", comment: "Moroccan dirham." },
8672 EnumValueDef { id: "Currency.MDL", comment: "Moldovan leu." },
8673 EnumValueDef { id: "Currency.MGA", comment: "Malagasy ariary." },
8674 EnumValueDef { id: "Currency.MKD", comment: "Macedonian denar." },
8675 EnumValueDef { id: "Currency.MMK", comment: "Myanma kyat." },
8676 EnumValueDef { id: "Currency.MNT", comment: "Mongolian tugrik." },
8677 EnumValueDef { id: "Currency.MOP", comment: "Macanese pataca." },
8678 EnumValueDef { id: "Currency.MRO", comment: "Mauritanian ouguiya." },
8679 EnumValueDef { id: "Currency.MUR", comment: "Mauritian rupee." },
8680 EnumValueDef { id: "Currency.MVR", comment: "Maldivian rufiyaa." },
8681 EnumValueDef { id: "Currency.MWK", comment: "Malawian kwacha." },
8682 EnumValueDef { id: "Currency.MXN", comment: "Mexican peso." },
8683 EnumValueDef { id: "Currency.MYR", comment: "Malaysian ringgit." },
8684 EnumValueDef { id: "Currency.MZN", comment: "Mozambican metical." },
8685 EnumValueDef { id: "Currency.NAD", comment: "Namibian dollar." },
8686 EnumValueDef { id: "Currency.NGN", comment: "Nigerian naira." },
8687 EnumValueDef { id: "Currency.NIO", comment: "Cordoba oro." },
8688 EnumValueDef { id: "Currency.NOK", comment: "Norwegian krone." },
8689 EnumValueDef { id: "Currency.NPR", comment: "Nepalese rupee." },
8690 EnumValueDef { id: "Currency.NZD", comment: "New Zealand dollar." },
8691 EnumValueDef { id: "Currency.OMR", comment: "Omani rial." },
8692 EnumValueDef { id: "Currency.PAB", comment: "Panamanian balboa." },
8693 EnumValueDef { id: "Currency.PEN", comment: "Peruvian nuevo sol." },
8694 EnumValueDef { id: "Currency.PGK", comment: "Papua New Guinean kina." },
8695 EnumValueDef { id: "Currency.PHP", comment: "Philippine peso." },
8696 EnumValueDef { id: "Currency.PKR", comment: "Pakistani rupee." },
8697 EnumValueDef { id: "Currency.PLN", comment: "Polish zloty." },
8698 EnumValueDef { id: "Currency.PYG", comment: "Paraguayan guaraní." },
8699 EnumValueDef { id: "Currency.QAR", comment: "Qatari rial." },
8700 EnumValueDef { id: "Currency.RON", comment: "Romanian new leu." },
8701 EnumValueDef { id: "Currency.RSD", comment: "Serbian dinar." },
8702 EnumValueDef { id: "Currency.RUB", comment: "Russian rouble." },
8703 EnumValueDef { id: "Currency.RWF", comment: "Rwandan franc." },
8704 EnumValueDef { id: "Currency.SAR", comment: "Saudi riyal." },
8705 EnumValueDef { id: "Currency.SBD", comment: "Solomon Islands dollar." },
8706 EnumValueDef { id: "Currency.SCR", comment: "Seychelles rupee." },
8707 EnumValueDef { id: "Currency.SDG", comment: "Sudanese pound." },
8708 EnumValueDef { id: "Currency.SEK", comment: "Swedish krona/kronor." },
8709 EnumValueDef { id: "Currency.SGD", comment: "Singapore dollar." },
8710 EnumValueDef { id: "Currency.SHP", comment: "Saint Helena pound." },
8711 EnumValueDef { id: "Currency.SLL", comment: "Sierra Leonean leone." },
8712 EnumValueDef { id: "Currency.SOS", comment: "Somali shilling." },
8713 EnumValueDef { id: "Currency.SRD", comment: "Surinamese dollar." },
8714 EnumValueDef { id: "Currency.STD", comment: "São Tomé and Príncipe dobra." },
8715 EnumValueDef { id: "Currency.SYP", comment: "Syrian pound." },
8716 EnumValueDef { id: "Currency.SZL", comment: "Lilangeni." },
8717 EnumValueDef { id: "Currency.THB", comment: "Thai baht." },
8718 EnumValueDef { id: "Currency.TJS", comment: "Tajikistani somoni." },
8719 EnumValueDef { id: "Currency.TMT", comment: "Turkmenistani manat." },
8720 EnumValueDef { id: "Currency.TND", comment: "Tunisian dinar." },
8721 EnumValueDef { id: "Currency.TOP", comment: "Tongan pa'anga." },
8722 EnumValueDef { id: "Currency.TRY", comment: "Turkish lira." },
8723 EnumValueDef { id: "Currency.TTD", comment: "Trinidad and Tobago dollar." },
8724 EnumValueDef { id: "Currency.TWD", comment: "New Taiwan dollar." },
8725 EnumValueDef { id: "Currency.TZS", comment: "Tanzanian shilling." },
8726 EnumValueDef { id: "Currency.UAH", comment: "Ukrainian hryvnia." },
8727 EnumValueDef { id: "Currency.UGX", comment: "Ugandan shilling." },
8728 EnumValueDef { id: "Currency.USD", comment: "United States dollar." },
8729 EnumValueDef { id: "Currency.UYU", comment: "Uruguayan peso." },
8730 EnumValueDef { id: "Currency.UZS", comment: "Uzbekistan som." },
8731 EnumValueDef { id: "Currency.VEF", comment: "Venezuelan bolívar fuerte." },
8732 EnumValueDef { id: "Currency.VND", comment: "Vietnamese Dong." },
8733 EnumValueDef { id: "Currency.VUV", comment: "Vanuatu vatu." },
8734 EnumValueDef { id: "Currency.WST", comment: "Samoan tala." },
8735 EnumValueDef { id: "Currency.XAF", comment: "CFA franc BEAC." },
8736 EnumValueDef { id: "Currency.XCD", comment: "East Caribbean dollar." },
8737 EnumValueDef { id: "Currency.XOF", comment: "CFA Franc BCEAO." },
8738 EnumValueDef { id: "Currency.XPF", comment: "CFP franc." },
8739 EnumValueDef { id: "Currency.YER", comment: "Yemeni rial." },
8740 EnumValueDef { id: "Currency.ZAR", comment: "South African rand." },
8741 EnumValueDef { id: "Currency.ZMK", comment: "Zambian kwacha." },
8742 EnumValueDef { id: "Currency.ZWL", comment: "Zimbabwe dollar." },
8743 ],
8744 },
8745 EnumDef {
8746 ns: "http://iec.ch/TC57/CIM100#",
8747 local: "CurveStyle",
8748 comment: "Style or shape of curve.",
8749 values: &[
8750 EnumValueDef { id: "CurveStyle.constantYValue", comment: "The Y-axis values are assumed constant until the next curve point and prior to the first curve point." },
8751 EnumValueDef { id: "CurveStyle.straightLineYValues", comment: "The Y-axis values are assumed to be a straight line between values. Also known as linear interpolation." },
8752 ],
8753 },
8754 EnumDef {
8755 ns: "http://iec.ch/TC57/CIM100#",
8756 local: "DCConverterOperatingModeKind",
8757 comment: "The operating mode of an HVDC bipole.",
8758 values: &[
8759 EnumValueDef { id: "DCConverterOperatingModeKind.bipolar", comment: "Bipolar operation." },
8760 EnumValueDef { id: "DCConverterOperatingModeKind.monopolarMetallicReturn", comment: "Monopolar operation with metallic return." },
8761 EnumValueDef { id: "DCConverterOperatingModeKind.monopolarGroundReturn", comment: "Monopolar operation with ground return." },
8762 ],
8763 },
8764 EnumDef {
8765 ns: "http://iec.ch/TC57/CIM100#",
8766 local: "DCPolarityKind",
8767 comment: "Polarity for DC circuits.",
8768 values: &[
8769 EnumValueDef { id: "DCPolarityKind.positive", comment: "Positive pole. The converter terminal is intended to operate at a positive voltage relative the midpoint or negative terminal." },
8770 EnumValueDef { id: "DCPolarityKind.middle", comment: "Middle pole. The converter terminal is the midpoint in a bipolar or symmetric monopole configuration. The midpoint can be grounded and/or have a metallic return." },
8771 EnumValueDef { id: "DCPolarityKind.negative", comment: "Negative pole. The converter terminal is intended to operate at a negative voltage relative the midpoint or positive terminal." },
8772 ],
8773 },
8774 EnumDef {
8775 ns: "http://iec.ch/TC57/CIM100#",
8776 local: "DroopSignalFeedbackKind",
8777 comment: "Governor droop signal feedback source.",
8778 values: &[
8779 EnumValueDef { id: "DroopSignalFeedbackKind.electricalPower", comment: "Electrical power feedback (connection indicated as 1 in the block diagrams of models, e.g. GovCT1, GovCT2)." },
8780 EnumValueDef { id: "DroopSignalFeedbackKind.none", comment: "No droop signal feedback, is isochronous governor." },
8781 EnumValueDef { id: "DroopSignalFeedbackKind.fuelValveStroke", comment: "Fuel valve stroke feedback (true stroke) (connection indicated as 2 in the block diagrams of model, e.g. GovCT1, GovCT2)." },
8782 EnumValueDef { id: "DroopSignalFeedbackKind.governorOutput", comment: "Governor output feedback (requested stroke) (connection indicated as 3 in the block diagrams of models, e.g. GovCT1, GovCT2)." },
8783 ],
8784 },
8785 EnumDef {
8786 ns: "http://iec.ch/TC57/CIM100#",
8787 local: "ExcIEEEST1AUELselectorKind",
8788 comment: "Types of connections for the UEL input used in ExcIEEEST1A.",
8789 values: &[
8790 EnumValueDef { id: "ExcIEEEST1AUELselectorKind.ignoreUELsignal", comment: "Ignore UEL signal." },
8791 EnumValueDef { id: "ExcIEEEST1AUELselectorKind.inputHVgateVoltageOutput", comment: "UEL input HV gate with voltage regulator output." },
8792 EnumValueDef { id: "ExcIEEEST1AUELselectorKind.inputHVgateErrorSignal", comment: "UEL input HV gate with error signal." },
8793 EnumValueDef { id: "ExcIEEEST1AUELselectorKind.inputAddedToErrorSignal", comment: "UEL input added to error signal." },
8794 ],
8795 },
8796 EnumDef {
8797 ns: "http://iec.ch/TC57/CIM100#",
8798 local: "ExcREXSFeedbackSignalKind",
8799 comment: "Types of rate feedback signals.",
8800 values: &[
8801 EnumValueDef { id: "ExcREXSFeedbackSignalKind.fieldVoltage", comment: "The voltage regulator output voltage is used. It is the same as exciter field voltage." },
8802 EnumValueDef { id: "ExcREXSFeedbackSignalKind.fieldCurrent", comment: "The exciter field current is used." },
8803 EnumValueDef { id: "ExcREXSFeedbackSignalKind.outputVoltage", comment: "The output voltage of the exciter is used." },
8804 ],
8805 },
8806 EnumDef {
8807 ns: "http://iec.ch/TC57/CIM100#",
8808 local: "ExcST6BOELselectorKind",
8809 comment: "Types of connections for the OEL input used for static excitation systems type 6B.",
8810 values: &[
8811 EnumValueDef { id: "ExcST6BOELselectorKind.noOELinput", comment: "No OEL input is used. Corresponds to OELin not = 1 and not = 2 on the ExcST6B diagram. Original ExcST6B model would have called this OELin = 0." },
8812 EnumValueDef { id: "ExcST6BOELselectorKind.beforeUEL", comment: "The connection is before UEL. Corresponds to OELin = 1 on the ExcST6B diagram." },
8813 EnumValueDef { id: "ExcST6BOELselectorKind.afterUEL", comment: "The connection is after UEL. Corresponds to OELin = 2 on the ExcST6B diagram." },
8814 ],
8815 },
8816 EnumDef {
8817 ns: "http://iec.ch/TC57/CIM100#",
8818 local: "ExcST7BOELselectorKind",
8819 comment: "Types of connections for the OEL input used for static excitation systems type 7B.",
8820 values: &[
8821 EnumValueDef { id: "ExcST7BOELselectorKind.noOELinput", comment: "No OEL input is used. Corresponds to OELin not = 1 and not = 2 and not = 3 on the ExcST7B diagram. Original ExcST7B model would have called this OELin = 0." },
8822 EnumValueDef { id: "ExcST7BOELselectorKind.addVref", comment: "The signal is added to Vref. Corresponds to OELin = 1 on the ExcST7B diagram." },
8823 EnumValueDef { id: "ExcST7BOELselectorKind.inputLVgate", comment: "The signal is connected into the input LVGate. Corresponds to OELin = 2 on the ExcST7B diagram." },
8824 EnumValueDef { id: "ExcST7BOELselectorKind.outputLVgate", comment: "The signal is connected into the output LVGate. Corresponds to OELin = 3 on the ExcST7B diagram." },
8825 ],
8826 },
8827 EnumDef {
8828 ns: "http://iec.ch/TC57/CIM100#",
8829 local: "ExcST7BUELselectorKind",
8830 comment: "Types of connections for the UEL input used for static excitation systems type 7B.",
8831 values: &[
8832 EnumValueDef { id: "ExcST7BUELselectorKind.noUELinput", comment: "No UEL input is used. Corresponds to UELin not = 1 and not = 2 and not = 3 on the ExcST7B diagram. Original ExcST7B model would have called this UELin = 0." },
8833 EnumValueDef { id: "ExcST7BUELselectorKind.addVref", comment: "The signal is added to Vref. Corresponds to UELin = 1 on the ExcST7B diagram." },
8834 EnumValueDef { id: "ExcST7BUELselectorKind.inputHVgate", comment: "The signal is connected into the input HVGate. Corresponds to UELin = 2 on the ExcST7B diagram." },
8835 EnumValueDef { id: "ExcST7BUELselectorKind.outputHVgate", comment: "The signal is connected into the output HVGate. Corresponds to UELin = 3 on the ExcST7B diagram." },
8836 ],
8837 },
8838 EnumDef {
8839 ns: "http://iec.ch/TC57/CIM100#",
8840 local: "FrancisGovernorControlKind",
8841 comment: "Governor control flag for Francis hydro model.",
8842 values: &[
8843 EnumValueDef { id: "FrancisGovernorControlKind.mechanicHydrolicTachoAccelerator", comment: "Mechanic-hydraulic regulator with tacho-accelerometer (Cflag = 1)." },
8844 EnumValueDef { id: "FrancisGovernorControlKind.mechanicHydraulicTransientFeedback", comment: "Mechanic-hydraulic regulator with transient feedback (Cflag=2)." },
8845 EnumValueDef { id: "FrancisGovernorControlKind.electromechanicalElectrohydraulic", comment: "Electromechanical and electrohydraulic regulator (Cflag=3)." },
8846 ],
8847 },
8848 EnumDef {
8849 ns: "http://iec.ch/TC57/CIM100#",
8850 local: "FuelType",
8851 comment: "Type of fuel.",
8852 values: &[
8853 EnumValueDef { id: "FuelType.coal", comment: "Generic coal, not including lignite type." },
8854 EnumValueDef { id: "FuelType.oil", comment: "Oil." },
8855 EnumValueDef { id: "FuelType.gas", comment: "Natural gas." },
8856 EnumValueDef { id: "FuelType.lignite", comment: "The fuel is lignite coal. Note that this is a special type of coal, so the other enum of coal is reserved for hard coal types or if the exact type of coal is not known." },
8857 EnumValueDef { id: "FuelType.hardCoal", comment: "Hard coal." },
8858 EnumValueDef { id: "FuelType.oilShale", comment: "Oil Shale." },
8859 EnumValueDef { id: "FuelType.brownCoalLignite", comment: "Brown coal lignite." },
8860 EnumValueDef { id: "FuelType.coalDerivedGas", comment: "Coal derived gas." },
8861 EnumValueDef { id: "FuelType.peat", comment: "Peat." },
8862 EnumValueDef { id: "FuelType.other", comment: "Any fuel type not included in the rest of the enumerated value." },
8863 ],
8864 },
8865 EnumDef {
8866 ns: "http://iec.ch/TC57/CIM100#",
8867 local: "GeneratorControlSource",
8868 comment: "The source of controls for a generating unit.",
8869 values: &[
8870 EnumValueDef { id: "GeneratorControlSource.unavailable", comment: "Not available." },
8871 EnumValueDef { id: "GeneratorControlSource.offAGC", comment: "Off of automatic generation control (AGC)." },
8872 EnumValueDef { id: "GeneratorControlSource.onAGC", comment: "On automatic generation control (AGC)." },
8873 EnumValueDef { id: "GeneratorControlSource.plantControl", comment: "Plant is controlling." },
8874 ],
8875 },
8876 EnumDef {
8877 ns: "http://iec.ch/TC57/CIM100#",
8878 local: "GenericNonLinearLoadModelKind",
8879 comment: "Type of generic non-linear load model.",
8880 values: &[
8881 EnumValueDef { id: "GenericNonLinearLoadModelKind.exponentialRecovery", comment: "Exponential recovery model." },
8882 EnumValueDef { id: "GenericNonLinearLoadModelKind.loadAdaptive", comment: "Load adaptive model." },
8883 ],
8884 },
8885 EnumDef {
8886 ns: "http://iec.ch/TC57/CIM100#",
8887 local: "GovHydro4ModelKind",
8888 comment: "Possible types of GovHydro4 models.",
8889 values: &[
8890 EnumValueDef { id: "GovHydro4ModelKind.simple", comment: "Simple model." },
8891 EnumValueDef { id: "GovHydro4ModelKind.francisPelton", comment: "Francis or Pelton model." },
8892 EnumValueDef { id: "GovHydro4ModelKind.kaplan", comment: "Kaplan model." },
8893 ],
8894 },
8895 EnumDef {
8896 ns: "http://iec.ch/TC57/CIM100#",
8897 local: "HydroEnergyConversionKind",
8898 comment: "Specifies the capability of the hydro generating unit to convert energy as a generator or pump.",
8899 values: &[
8900 EnumValueDef { id: "HydroEnergyConversionKind.generator", comment: "Able to generate power, but not able to pump water for energy storage." },
8901 EnumValueDef { id: "HydroEnergyConversionKind.pumpAndGenerator", comment: "Able to both generate power and pump water for energy storage." },
8902 ],
8903 },
8904 EnumDef {
8905 ns: "http://iec.ch/TC57/CIM100#",
8906 local: "HydroPlantStorageKind",
8907 comment: "The type of hydro power plant.",
8908 values: &[
8909 EnumValueDef { id: "HydroPlantStorageKind.runOfRiver", comment: "Run of river." },
8910 EnumValueDef { id: "HydroPlantStorageKind.pumpedStorage", comment: "Pumped storage." },
8911 EnumValueDef { id: "HydroPlantStorageKind.storage", comment: "Storage." },
8912 ],
8913 },
8914 EnumDef {
8915 ns: "http://iec.ch/TC57/CIM100#",
8916 local: "HydroTurbineKind",
8917 comment: "Type of turbine.",
8918 values: &[
8919 EnumValueDef { id: "HydroTurbineKind.francis", comment: "Francis." },
8920 EnumValueDef { id: "HydroTurbineKind.pelton", comment: "Pelton." },
8921 EnumValueDef { id: "HydroTurbineKind.kaplan", comment: "Kaplan." },
8922 ],
8923 },
8924 EnumDef {
8925 ns: "http://iec.ch/TC57/CIM100#",
8926 local: "IfdBaseKind",
8927 comment: "Excitation base system mode.",
8928 values: &[
8929 EnumValueDef { id: "IfdBaseKind.ifag", comment: "Air gap line mode." },
8930 EnumValueDef { id: "IfdBaseKind.ifnl", comment: "No load system with saturation mode." },
8931 EnumValueDef { id: "IfdBaseKind.iffl", comment: "Full load system mode." },
8932 ],
8933 },
8934 EnumDef {
8935 ns: "http://iec.ch/TC57/CIM100#",
8936 local: "InputSignalKind",
8937 comment: "Types of input signals. In dynamics modelling, commonly represented by the j parameter.",
8938 values: &[
8939 EnumValueDef { id: "InputSignalKind.rotorSpeed", comment: "Input signal is rotor or shaft speed (angular frequency)." },
8940 EnumValueDef { id: "InputSignalKind.rotorAngularFrequencyDeviation", comment: "Input signal is rotor or shaft angular frequency deviation." },
8941 EnumValueDef { id: "InputSignalKind.busFrequency", comment: "Input signal is bus voltage frequency. This could be a terminal frequency or remote frequency." },
8942 EnumValueDef { id: "InputSignalKind.busFrequencyDeviation", comment: "Input signal is deviation of bus voltage frequency. This could be a terminal frequency deviation or remote frequency deviation." },
8943 EnumValueDef { id: "InputSignalKind.generatorElectricalPower", comment: "Input signal is generator electrical power on rated S." },
8944 EnumValueDef { id: "InputSignalKind.generatorAcceleratingPower", comment: "Input signal is generator accelerating power." },
8945 EnumValueDef { id: "InputSignalKind.busVoltage", comment: "Input signal is bus voltage. This could be a terminal voltage or remote voltage." },
8946 EnumValueDef { id: "InputSignalKind.busVoltageDerivative", comment: "Input signal is derivative of bus voltage. This could be a terminal voltage derivative or remote voltage derivative." },
8947 EnumValueDef { id: "InputSignalKind.branchCurrent", comment: "Input signal is amplitude of remote branch current." },
8948 EnumValueDef { id: "InputSignalKind.fieldCurrent", comment: "Input signal is generator field current." },
8949 EnumValueDef { id: "InputSignalKind.generatorMechanicalPower", comment: "Input signal is generator mechanical power." },
8950 ],
8951 },
8952 EnumDef {
8953 ns: "http://iec.ch/TC57/CIM100#",
8954 local: "OperationalLimitDirectionKind",
8955 comment: "The direction attribute describes the side of a limit that is a violation.",
8956 values: &[
8957 EnumValueDef { id: "OperationalLimitDirectionKind.high", comment: "High means that a monitored value above the limit value is a violation. If applied to a terminal flow, the positive direction is into the terminal." },
8958 EnumValueDef { id: "OperationalLimitDirectionKind.low", comment: "Low means a monitored value below the limit is a violation. If applied to a terminal flow, the positive direction is into the terminal." },
8959 EnumValueDef { id: "OperationalLimitDirectionKind.absoluteValue", comment: "An absoluteValue limit means that a monitored absolute value above the limit value is a violation." },
8960 ],
8961 },
8962 EnumDef {
8963 ns: "http://iec.ch/TC57/CIM100#",
8964 local: "OrientationKind",
8965 comment: "The orientation of the coordinate system with respect to top, left, and the coordinate number system.",
8966 values: &[
8967 EnumValueDef { id: "OrientationKind.positive", comment: "For 2D diagrams, a positive orientation will result in X values increasing from left to right and Y values increasing from bottom to top. This is also known as a right hand orientation." },
8968 EnumValueDef { id: "OrientationKind.negative", comment: "For 2D diagrams, a negative orientation gives the left-hand orientation (favoured by computer graphics displays) with X values increasing from left to right and Y values increasing from top to bottom. This is also known as a left hand orientation." },
8969 ],
8970 },
8971 EnumDef {
8972 ns: "http://iec.ch/TC57/CIM100#",
8973 local: "PetersenCoilModeKind",
8974 comment: "The mode of operation for a Petersen coil.",
8975 values: &[
8976 EnumValueDef { id: "PetersenCoilModeKind.fixed", comment: "Fixed position." },
8977 EnumValueDef { id: "PetersenCoilModeKind.manual", comment: "Manual positioning." },
8978 EnumValueDef { id: "PetersenCoilModeKind.automaticPositioning", comment: "Automatic positioning." },
8979 ],
8980 },
8981 EnumDef {
8982 ns: "http://iec.ch/TC57/CIM100#",
8983 local: "PhaseCode",
8984 comment: "An unordered enumeration of phase identifiers. Allows designation of phases for both transmission and distribution equipment, circuits and loads. The enumeration, by itself, does not describe how the phases are connected together or connected to ground. Ground is not explicitly denoted as a phase. Residential and small commercial loads are often served from single-phase, or split-phase, secondary circuits. For the example of s12N, phases 1 and 2 refer to hot wires that are 180 degrees out of phase, while N refers to the neutral wire. Through single-phase transformer connections, these secondary circuits may be served from one or two of the primary phases A, B, and C. For three-phase loads, use the A, B, C phase codes instead of s12N. The integer values are from IEC 61968-9 to support revenue metering applications.",
8985 values: &[
8986 EnumValueDef { id: "PhaseCode.ABCN", comment: "Phases A, B, C, and N." },
8987 EnumValueDef { id: "PhaseCode.ABC", comment: "Phases A, B, and C." },
8988 EnumValueDef { id: "PhaseCode.ABN", comment: "Phases A, B, and neutral." },
8989 EnumValueDef { id: "PhaseCode.ACN", comment: "Phases A, C and neutral." },
8990 EnumValueDef { id: "PhaseCode.BCN", comment: "Phases B, C, and neutral." },
8991 EnumValueDef { id: "PhaseCode.AB", comment: "Phases A and B." },
8992 EnumValueDef { id: "PhaseCode.AC", comment: "Phases A and C." },
8993 EnumValueDef { id: "PhaseCode.BC", comment: "Phases B and C." },
8994 EnumValueDef { id: "PhaseCode.AN", comment: "Phases A and neutral." },
8995 EnumValueDef { id: "PhaseCode.BN", comment: "Phases B and neutral." },
8996 EnumValueDef { id: "PhaseCode.CN", comment: "Phases C and neutral." },
8997 EnumValueDef { id: "PhaseCode.A", comment: "Phase A." },
8998 EnumValueDef { id: "PhaseCode.B", comment: "Phase B." },
8999 EnumValueDef { id: "PhaseCode.C", comment: "Phase C." },
9000 EnumValueDef { id: "PhaseCode.N", comment: "Neutral phase." },
9001 EnumValueDef { id: "PhaseCode.s1N", comment: "Secondary phase 1 and neutral." },
9002 EnumValueDef { id: "PhaseCode.s2N", comment: "Secondary phase 2 and neutral." },
9003 EnumValueDef { id: "PhaseCode.s12N", comment: "Secondary phases 1, 2, and neutral." },
9004 EnumValueDef { id: "PhaseCode.s1", comment: "Secondary phase 1." },
9005 EnumValueDef { id: "PhaseCode.s2", comment: "Secondary phase 2." },
9006 EnumValueDef { id: "PhaseCode.s12", comment: "Secondary phase 1 and 2." },
9007 EnumValueDef { id: "PhaseCode.none", comment: "No phases specified." },
9008 EnumValueDef { id: "PhaseCode.X", comment: "Unknown non-neutral phase." },
9009 EnumValueDef { id: "PhaseCode.XY", comment: "Two unknown non-neutral phases." },
9010 EnumValueDef { id: "PhaseCode.XN", comment: "Unknown non-neutral phase plus neutral." },
9011 EnumValueDef { id: "PhaseCode.XYN", comment: "Two unknown non-neutral phases plus neutral." },
9012 ],
9013 },
9014 EnumDef {
9015 ns: "http://iec.ch/TC57/CIM100#",
9016 local: "RegulatingControlModeKind",
9017 comment: "The kind of regulation model. For example regulating voltage, reactive power, active power, etc.",
9018 values: &[
9019 EnumValueDef { id: "RegulatingControlModeKind.voltage", comment: "Voltage is specified." },
9020 EnumValueDef { id: "RegulatingControlModeKind.activePower", comment: "Active power is specified." },
9021 EnumValueDef { id: "RegulatingControlModeKind.reactivePower", comment: "Reactive power is specified." },
9022 EnumValueDef { id: "RegulatingControlModeKind.currentFlow", comment: "Current flow is specified." },
9023 EnumValueDef { id: "RegulatingControlModeKind.admittance", comment: "Admittance is specified." },
9024 EnumValueDef { id: "RegulatingControlModeKind.timeScheduled", comment: "Control switches on/off by time of day. The times may change on the weekend, or in different seasons." },
9025 EnumValueDef { id: "RegulatingControlModeKind.temperature", comment: "Control switches on/off based on the local temperature (i.e., a thermostat)." },
9026 EnumValueDef { id: "RegulatingControlModeKind.powerFactor", comment: "Power factor is specified." },
9027 ],
9028 },
9029 EnumDef {
9030 ns: "http://iec.ch/TC57/CIM100#",
9031 local: "RemoteSignalKind",
9032 comment: "Type of input signal coming from remote bus.",
9033 values: &[
9034 EnumValueDef { id: "RemoteSignalKind.remoteBusVoltageFrequency", comment: "Input is voltage frequency from remote terminal bus." },
9035 EnumValueDef { id: "RemoteSignalKind.remoteBusVoltageFrequencyDeviation", comment: "Input is voltage frequency deviation from remote terminal bus." },
9036 EnumValueDef { id: "RemoteSignalKind.remoteBusFrequency", comment: "Input is frequency from remote terminal bus." },
9037 EnumValueDef { id: "RemoteSignalKind.remoteBusFrequencyDeviation", comment: "Input is frequency deviation from remote terminal bus." },
9038 EnumValueDef { id: "RemoteSignalKind.remoteBusVoltageAmplitude", comment: "Input is voltage amplitude from remote terminal bus." },
9039 EnumValueDef { id: "RemoteSignalKind.remoteBusVoltage", comment: "Input is voltage from remote terminal bus." },
9040 EnumValueDef { id: "RemoteSignalKind.remoteBranchCurrentAmplitude", comment: "Input is branch current amplitude from remote terminal bus." },
9041 EnumValueDef { id: "RemoteSignalKind.remoteBusVoltageAmplitudeDerivative", comment: "Input is branch current amplitude derivative from remote terminal bus." },
9042 EnumValueDef { id: "RemoteSignalKind.remotePuBusVoltageDerivative", comment: "Input is PU voltage derivative from remote terminal bus." },
9043 ],
9044 },
9045 EnumDef {
9046 ns: "http://iec.ch/TC57/CIM100#",
9047 local: "RotorKind",
9048 comment: "Type of rotor on physical machine.",
9049 values: &[
9050 EnumValueDef { id: "RotorKind.roundRotor", comment: "Round rotor type of synchronous machine." },
9051 EnumValueDef { id: "RotorKind.salientPole", comment: "Salient pole type of synchronous machine." },
9052 ],
9053 },
9054 EnumDef {
9055 ns: "http://iec.ch/TC57/CIM100#",
9056 local: "ShortCircuitRotorKind",
9057 comment: "Type of rotor, used by short circuit applications.",
9058 values: &[
9059 EnumValueDef { id: "ShortCircuitRotorKind.salientPole1", comment: "Salient pole 1 in IEC 60909." },
9060 EnumValueDef { id: "ShortCircuitRotorKind.salientPole2", comment: "Salient pole 2 in IEC 60909." },
9061 EnumValueDef { id: "ShortCircuitRotorKind.turboSeries1", comment: "Turbo Series 1 in IEC 60909." },
9062 EnumValueDef { id: "ShortCircuitRotorKind.turboSeries2", comment: "Turbo series 2 in IEC 60909." },
9063 ],
9064 },
9065 EnumDef {
9066 ns: "http://iec.ch/TC57/CIM100#",
9067 local: "Source",
9068 comment: "Source gives information related to the origin of a value.",
9069 values: &[
9070 EnumValueDef { id: "Source.PROCESS", comment: "The value is provided by input from the process I/O or being calculated from some function." },
9071 EnumValueDef { id: "Source.DEFAULTED", comment: "The value contains a default value." },
9072 EnumValueDef { id: "Source.SUBSTITUTED", comment: "The value is provided by input of an operator or by an automatic source." },
9073 ],
9074 },
9075 EnumDef {
9076 ns: "http://iec.ch/TC57/CIM100#",
9077 local: "StaticLoadModelKind",
9078 comment: "Type of static load model.",
9079 values: &[
9080 EnumValueDef { id: "StaticLoadModelKind.exponential", comment: "This model is an exponential representation of the load. Exponential equations for active and reactive power are used and the following attributes are required: kp1, kp2, kp3, kpf, ep1, ep2, ep3 kq1, kq2, kq3, kqf, eq1, eq2, eq3." },
9081 EnumValueDef { id: "StaticLoadModelKind.zIP1", comment: "This model integrates the frequency-dependent load (primarily motors). ZIP1 equations for active and reactive power are used and the following attributes are required: kp1, kp2, kp3, kpf kq1, kq2, kq3, kqf." },
9082 EnumValueDef { id: "StaticLoadModelKind.zIP2", comment: "This model separates the frequency-dependent load (primarily motors) from other load. ZIP2 equations for active and reactive power are used and the following attributes are required: kp1, kp2, kp3, kq4, kpf kq1, kq2, kq3, kq4, kqf." },
9083 EnumValueDef { id: "StaticLoadModelKind.constantZ", comment: "The load is represented as a constant impedance. ConstantZ equations are used for active and reactive power and no attributes are required." },
9084 ],
9085 },
9086 EnumDef {
9087 ns: "http://iec.ch/TC57/CIM100#",
9088 local: "SynchronousMachineKind",
9089 comment: "Synchronous machine type.",
9090 values: &[
9091 EnumValueDef { id: "SynchronousMachineKind.generator", comment: "Indicates the synchronous machine can operate as a generator." },
9092 EnumValueDef { id: "SynchronousMachineKind.condenser", comment: "Indicates the synchronous machine can operate as a condenser." },
9093 EnumValueDef { id: "SynchronousMachineKind.generatorOrCondenser", comment: "Indicates the synchronous machine can operate as a generator or as a condenser." },
9094 EnumValueDef { id: "SynchronousMachineKind.motor", comment: "Indicates the synchronous machine can operate as a motor." },
9095 EnumValueDef { id: "SynchronousMachineKind.generatorOrMotor", comment: "Indicates the synchronous machine can operate as a generator or as a motor." },
9096 EnumValueDef { id: "SynchronousMachineKind.motorOrCondenser", comment: "Indicates the synchronous machine can operate as a motor or as a condenser." },
9097 EnumValueDef { id: "SynchronousMachineKind.generatorOrCondenserOrMotor", comment: "Indicates the synchronous machine can operate as a generator or as a condenser or as a motor." },
9098 ],
9099 },
9100 EnumDef {
9101 ns: "http://iec.ch/TC57/CIM100#",
9102 local: "SynchronousMachineModelKind",
9103 comment: "Type of synchronous machine model used in dynamic simulation applications.",
9104 values: &[
9105 EnumValueDef { id: "SynchronousMachineModelKind.subtransient", comment: "Subtransient synchronous machine model." },
9106 EnumValueDef { id: "SynchronousMachineModelKind.subtransientTypeF", comment: "WECC type F variant of subtransient synchronous machine model." },
9107 EnumValueDef { id: "SynchronousMachineModelKind.subtransientTypeJ", comment: "WECC type J variant of subtransient synchronous machine model." },
9108 EnumValueDef { id: "SynchronousMachineModelKind.subtransientSimplified", comment: "Simplified version of subtransient synchronous machine model where magnetic coupling between the direct- and quadrature- axes is ignored." },
9109 EnumValueDef { id: "SynchronousMachineModelKind.subtransientSimplifiedDirectAxis", comment: "Simplified version of a subtransient synchronous machine model with no damper circuit on the direct-axis." },
9110 ],
9111 },
9112 EnumDef {
9113 ns: "http://iec.ch/TC57/CIM100#",
9114 local: "SynchronousMachineOperatingMode",
9115 comment: "Synchronous machine operating mode.",
9116 values: &[
9117 EnumValueDef { id: "SynchronousMachineOperatingMode.generator", comment: "Operating as generator." },
9118 EnumValueDef { id: "SynchronousMachineOperatingMode.condenser", comment: "Operating as condenser." },
9119 EnumValueDef { id: "SynchronousMachineOperatingMode.motor", comment: "Operating as motor." },
9120 ],
9121 },
9122 EnumDef {
9123 ns: "http://iec.ch/TC57/CIM100#",
9124 local: "UnitMultiplier",
9125 comment: "The unit multipliers defined for the CIM. When applied to unit symbols, the unit symbol is treated as a derived unit. Regardless of the contents of the unit symbol text, the unit symbol shall be treated as if it were a single-character unit symbol. Unit symbols should not contain multipliers, and it should be left to the multiplier to define the multiple for an entire data type. For example, if a unit symbol is 'm2Pers' and the multiplier is 'k', then the value is k(m**2/s), and the multiplier applies to the entire final value, not to any individual part of the value. This can be conceptualized by substituting a derived unit symbol for the unit type. If one imagines that the symbol 'Þ' represents the derived unit 'm2Pers', then applying the multiplier 'k' can be conceptualized simply as 'kÞ'. For example, the SI unit for mass is 'kg' and not 'g'. If the unit symbol is defined as 'kg', then the multiplier is applied to 'kg' as a whole and does not replace the 'k' in front of the 'g'. In this case, the multiplier of 'm' would be used with the unit symbol of 'kg' to represent one gram. As a text string, this violates the instructions in IEC 80000-1. However, because the unit symbol in CIM is treated as a derived unit instead of as an SI unit, it makes more sense to conceptualize the 'kg' as if it were replaced by one of the proposed replacements for the SI mass symbol. If one imagines that the 'kg' were replaced by a symbol 'Þ', then it is easier to conceptualize the multiplier 'm' as creating the proper unit 'mÞ', and not the forbidden unit 'mkg'.",
9126 values: &[
9127 EnumValueDef { id: "UnitMultiplier.y", comment: "Yocto 10**-24." },
9128 EnumValueDef { id: "UnitMultiplier.z", comment: "Zepto 10**-21." },
9129 EnumValueDef { id: "UnitMultiplier.a", comment: "Atto 10**-18." },
9130 EnumValueDef { id: "UnitMultiplier.f", comment: "Femto 10**-15." },
9131 EnumValueDef { id: "UnitMultiplier.p", comment: "Pico 10**-12." },
9132 EnumValueDef { id: "UnitMultiplier.n", comment: "Nano 10**-9." },
9133 EnumValueDef { id: "UnitMultiplier.micro", comment: "Micro 10**-6." },
9134 EnumValueDef { id: "UnitMultiplier.m", comment: "Milli 10**-3." },
9135 EnumValueDef { id: "UnitMultiplier.c", comment: "Centi 10**-2." },
9136 EnumValueDef { id: "UnitMultiplier.d", comment: "Deci 10**-1." },
9137 EnumValueDef { id: "UnitMultiplier.none", comment: "No multiplier or equivalently multiply by 1." },
9138 EnumValueDef { id: "UnitMultiplier.da", comment: "Deca 10**1." },
9139 EnumValueDef { id: "UnitMultiplier.h", comment: "Hecto 10**2." },
9140 EnumValueDef { id: "UnitMultiplier.k", comment: "Kilo 10**3." },
9141 EnumValueDef { id: "UnitMultiplier.M", comment: "Mega 10**6." },
9142 EnumValueDef { id: "UnitMultiplier.G", comment: "Giga 10**9." },
9143 EnumValueDef { id: "UnitMultiplier.T", comment: "Tera 10**12." },
9144 EnumValueDef { id: "UnitMultiplier.P", comment: "Peta 10**15." },
9145 EnumValueDef { id: "UnitMultiplier.E", comment: "Exa 10**18." },
9146 EnumValueDef { id: "UnitMultiplier.Z", comment: "Zetta 10**21." },
9147 EnumValueDef { id: "UnitMultiplier.Y", comment: "Yotta 10**24." },
9148 ],
9149 },
9150 EnumDef {
9151 ns: "http://iec.ch/TC57/CIM100#",
9152 local: "UnitSymbol",
9153 comment: "The derived units defined for usage in the CIM. In some cases, the derived unit is equal to an SI unit. Whenever possible, the standard derived symbol is used instead of the formula for the derived unit. For example, the unit symbol Farad is defined as 'F' instead of 'CPerV'. In cases where a standard symbol does not exist for a derived unit, the formula for the unit is used as the unit symbol. For example, density does not have a standard symbol and so it is represented as 'kgPerm3'. With the exception of the 'kg', which is an SI unit, the unit symbols do not contain multipliers and therefore represent the base derived unit to which a multiplier can be applied as a whole. Every unit symbol is treated as an unparseable text as if it were a single-letter symbol. The meaning of each unit symbol is defined by the accompanying descriptive text and not by the text contents of the unit symbol. To allow the widest possible range of serializations without requiring special character handling, several substitutions are made which deviate from the format described in IEC 80000-1. The division symbol '/' is replaced by the letters 'Per'. Exponents are written in plain text after the unit as 'm3' instead of being formatted as 'm' with a superscript of 3 or introducing a symbol as in 'm^3'. The degree symbol '°' is replaced with the letters 'deg'. Any clarification of the meaning for a substitution is included in the description for the unit symbol. Non-SI units are included in list of unit symbols to allow sources of data to be correctly labelled with their non-SI units (for example, a GPS sensor that is reporting numbers that represent feet instead of meters). This allows software to use the unit symbol information correctly convert and scale the raw data of those sources into SI-based units. The integer values are used for harmonization with IEC 61850.",
9154 values: &[
9155 EnumValueDef { id: "UnitSymbol.none", comment: "Dimension less quantity, e.g. count, per unit, etc." },
9156 EnumValueDef { id: "UnitSymbol.m", comment: "Length in metres." },
9157 EnumValueDef { id: "UnitSymbol.kg", comment: "Mass in kilograms. Note: multiplier “k” is included in this unit symbol for compatibility with IEC 61850-7-3." },
9158 EnumValueDef { id: "UnitSymbol.s", comment: "Time in seconds." },
9159 EnumValueDef { id: "UnitSymbol.A", comment: "Current in amperes." },
9160 EnumValueDef { id: "UnitSymbol.K", comment: "Temperature in kelvins." },
9161 EnumValueDef { id: "UnitSymbol.mol", comment: "Amount of substance in moles." },
9162 EnumValueDef { id: "UnitSymbol.cd", comment: "Luminous intensity in candelas." },
9163 EnumValueDef { id: "UnitSymbol.deg", comment: "Plane angle in degrees." },
9164 EnumValueDef { id: "UnitSymbol.rad", comment: "Plane angle in radians (m/m)." },
9165 EnumValueDef { id: "UnitSymbol.sr", comment: "Solid angle in steradians (m2/m2)." },
9166 EnumValueDef { id: "UnitSymbol.Gy", comment: "Absorbed dose in grays (J/kg)." },
9167 EnumValueDef { id: "UnitSymbol.Bq", comment: "Radioactivity in becquerels (1/s)." },
9168 EnumValueDef { id: "UnitSymbol.degC", comment: "Relative temperature in degrees Celsius. In the SI unit system the symbol is °C. Electric charge is measured in coulomb that has the unit symbol C. To distinguish degree Celsius from coulomb the symbol used in the UML is degC. The reason for not using °C is that the special character ° is difficult to manage in software." },
9169 EnumValueDef { id: "UnitSymbol.Sv", comment: "Dose equivalent in sieverts (J/kg)." },
9170 EnumValueDef { id: "UnitSymbol.F", comment: "Electric capacitance in farads (C/V)." },
9171 EnumValueDef { id: "UnitSymbol.C", comment: "Electric charge in coulombs (A·s)." },
9172 EnumValueDef { id: "UnitSymbol.S", comment: "Conductance in siemens." },
9173 EnumValueDef { id: "UnitSymbol.H", comment: "Electric inductance in henrys (Wb/A)." },
9174 EnumValueDef { id: "UnitSymbol.V", comment: "Electric potential in volts (W/A)." },
9175 EnumValueDef { id: "UnitSymbol.ohm", comment: "Electric resistance in ohms (V/A)." },
9176 EnumValueDef { id: "UnitSymbol.J", comment: "Energy in joules (N·m = C·V = W·s)." },
9177 EnumValueDef { id: "UnitSymbol.N", comment: "Force in newtons (kg·m/s²)." },
9178 EnumValueDef { id: "UnitSymbol.Hz", comment: "Frequency in hertz (1/s)." },
9179 EnumValueDef { id: "UnitSymbol.lx", comment: "Illuminance in lux (lm/m²)." },
9180 EnumValueDef { id: "UnitSymbol.lm", comment: "Luminous flux in lumens (cd·sr)." },
9181 EnumValueDef { id: "UnitSymbol.Wb", comment: "Magnetic flux in webers (V·s)." },
9182 EnumValueDef { id: "UnitSymbol.T", comment: "Magnetic flux density in teslas (Wb/m2)." },
9183 EnumValueDef { id: "UnitSymbol.W", comment: "Real power in watts (J/s). Electrical power may have real and reactive components. The real portion of electrical power (I²R or VIcos(phi)), is expressed in Watts. See also apparent power and reactive power." },
9184 EnumValueDef { id: "UnitSymbol.Pa", comment: "Pressure in pascals (N/m²). Note: the absolute or relative measurement of pressure is implied with this entry. See below for more explicit forms." },
9185 EnumValueDef { id: "UnitSymbol.m2", comment: "Area in square metres (m²)." },
9186 EnumValueDef { id: "UnitSymbol.m3", comment: "Volume in cubic metres (m³)." },
9187 EnumValueDef { id: "UnitSymbol.mPers", comment: "Velocity in metres per second (m/s)." },
9188 EnumValueDef { id: "UnitSymbol.mPers2", comment: "Acceleration in metres per second squared (m/s²)." },
9189 EnumValueDef { id: "UnitSymbol.m3Pers", comment: "Volumetric flow rate in cubic metres per second (m³/s)." },
9190 EnumValueDef { id: "UnitSymbol.mPerm3", comment: "Fuel efficiency in metres per cubic metres (m/m³)." },
9191 EnumValueDef { id: "UnitSymbol.kgm", comment: "Moment of mass in kilogram metres (kg·m) (first moment of mass). Note: multiplier “k” is included in this unit symbol for compatibility with IEC 61850-7-3." },
9192 EnumValueDef { id: "UnitSymbol.kgPerm3", comment: "Density in kilogram/cubic metres (kg/m³). Note: multiplier “k” is included in this unit symbol for compatibility with IEC 61850-7-3." },
9193 EnumValueDef { id: "UnitSymbol.m2Pers", comment: "Viscosity in square metres / second (m²/s)." },
9194 EnumValueDef { id: "UnitSymbol.WPermK", comment: "Thermal conductivity in watt/metres kelvin." },
9195 EnumValueDef { id: "UnitSymbol.JPerK", comment: "Heat capacity in joules/kelvin." },
9196 EnumValueDef { id: "UnitSymbol.ppm", comment: "Concentration in parts per million." },
9197 EnumValueDef { id: "UnitSymbol.rotPers", comment: "Rotations per second (1/s). See also Hz (1/s)." },
9198 EnumValueDef { id: "UnitSymbol.radPers", comment: "Angular velocity in radians per second (rad/s)." },
9199 EnumValueDef { id: "UnitSymbol.WPerm2", comment: "Heat flux density, irradiance, watts per square metre." },
9200 EnumValueDef { id: "UnitSymbol.JPerm2", comment: "Insulation energy density, joules per square metre or watt second per square metre." },
9201 EnumValueDef { id: "UnitSymbol.SPerm", comment: "Conductance per length (F/m)." },
9202 EnumValueDef { id: "UnitSymbol.KPers", comment: "Temperature change rate in kelvins per second." },
9203 EnumValueDef { id: "UnitSymbol.PaPers", comment: "Pressure change rate in pascals per second." },
9204 EnumValueDef { id: "UnitSymbol.JPerkgK", comment: "Specific heat capacity, specific entropy, joules per kilogram Kelvin." },
9205 EnumValueDef { id: "UnitSymbol.VA", comment: "Apparent power in volt amperes. See also real power and reactive power." },
9206 EnumValueDef { id: "UnitSymbol.VAr", comment: "Reactive power in volt amperes reactive. The “reactive” or “imaginary” component of electrical power (VIsin(phi)). (See also real power and apparent power). Note: Different meter designs use different methods to arrive at their results. Some meters may compute reactive power as an arithmetic value, while others compute the value vectorially. The data consumer should determine the method in use and the suitability of the measurement for the intended purpose." },
9207 EnumValueDef { id: "UnitSymbol.cosPhi", comment: "Power factor, dimensionless. Note 1: This definition of power factor only holds for balanced systems. See the alternative definition under code 153. Note 2 : Beware of differing sign conventions in use between the IEC and EEI. It is assumed that the data consumer understands the type of meter in use and the sign convention in use by the utility." },
9208 EnumValueDef { id: "UnitSymbol.Vs", comment: "Volt seconds (Ws/A)." },
9209 EnumValueDef { id: "UnitSymbol.V2", comment: "Volt squared (W²/A²)." },
9210 EnumValueDef { id: "UnitSymbol.As", comment: "Ampere seconds (A·s)." },
9211 EnumValueDef { id: "UnitSymbol.A2", comment: "Amperes squared (A²)." },
9212 EnumValueDef { id: "UnitSymbol.A2s", comment: "Ampere squared time in square amperes (A²s)." },
9213 EnumValueDef { id: "UnitSymbol.VAh", comment: "Apparent energy in volt ampere hours." },
9214 EnumValueDef { id: "UnitSymbol.Wh", comment: "Real energy in watt hours." },
9215 EnumValueDef { id: "UnitSymbol.VArh", comment: "Reactive energy in volt ampere reactive hours." },
9216 EnumValueDef { id: "UnitSymbol.VPerHz", comment: "Magnetic flux in volt per hertz." },
9217 EnumValueDef { id: "UnitSymbol.HzPers", comment: "Rate of change of frequency in hertz per second." },
9218 EnumValueDef { id: "UnitSymbol.character", comment: "Number of characters." },
9219 EnumValueDef { id: "UnitSymbol.charPers", comment: "Data rate (baud) in characters per second." },
9220 EnumValueDef { id: "UnitSymbol.kgm2", comment: "Moment of mass in kilogram square metres (kg·m²) (Second moment of mass, commonly called the moment of inertia). Note: multiplier “k” is included in this unit symbol for compatibility with IEC 61850-7-3." },
9221 EnumValueDef { id: "UnitSymbol.dB", comment: "Sound pressure level in decibels. Note: multiplier “d” is included in this unit symbol for compatibility with IEC 61850-7-3." },
9222 EnumValueDef { id: "UnitSymbol.WPers", comment: "Ramp rate in watts per second." },
9223 EnumValueDef { id: "UnitSymbol.lPers", comment: "Volumetric flow rate in litres per second." },
9224 EnumValueDef { id: "UnitSymbol.dBm", comment: "Power level (logarithmic ratio of signal strength , Bel-mW), normalized to 1mW. Note: multiplier “d” is included in this unit symbol for compatibility with IEC 61850-7-3." },
9225 EnumValueDef { id: "UnitSymbol.h", comment: "Time in hours, hour = 60 min = 3600 s." },
9226 EnumValueDef { id: "UnitSymbol.min", comment: "Time in minutes, minute = 60 s." },
9227 EnumValueDef { id: "UnitSymbol.Q", comment: "Quantity power, Q." },
9228 EnumValueDef { id: "UnitSymbol.Qh", comment: "Quantity energy, Qh." },
9229 EnumValueDef { id: "UnitSymbol.ohmm", comment: "Resistivity, ohm metres, (rho)." },
9230 EnumValueDef { id: "UnitSymbol.APerm", comment: "A/m, magnetic field strength, amperes per metre." },
9231 EnumValueDef { id: "UnitSymbol.V2h", comment: "Volt-squared hour, volt-squared-hours." },
9232 EnumValueDef { id: "UnitSymbol.A2h", comment: "Ampere-squared hour, ampere-squared hour." },
9233 EnumValueDef { id: "UnitSymbol.Ah", comment: "Ampere-hours, ampere-hours." },
9234 EnumValueDef { id: "UnitSymbol.count", comment: "Amount of substance, Counter value." },
9235 EnumValueDef { id: "UnitSymbol.ft3", comment: "Volume, cubic feet." },
9236 EnumValueDef { id: "UnitSymbol.m3Perh", comment: "Volumetric flow rate, cubic metres per hour." },
9237 EnumValueDef { id: "UnitSymbol.gal", comment: "Volume in gallons, US gallon (1 gal = 231 in3 = 128 fl ounce)." },
9238 EnumValueDef { id: "UnitSymbol.Btu", comment: "Energy, British Thermal Units." },
9239 EnumValueDef { id: "UnitSymbol.l", comment: "Volume in litres, litre = dm3 = m3/1000." },
9240 EnumValueDef { id: "UnitSymbol.lPerh", comment: "Volumetric flow rate, litres per hour." },
9241 EnumValueDef { id: "UnitSymbol.lPerl", comment: "Concentration, The ratio of the volume of a solute divided by the volume of the solution. Note: Users may need use a prefix such a ‘µ’ to express a quantity such as ‘µL/L’." },
9242 EnumValueDef { id: "UnitSymbol.gPerg", comment: "Concentration, The ratio of the mass of a solute divided by the mass of the solution. Note: Users may need use a prefix such a ‘µ’ to express a quantity such as ‘µg/g’." },
9243 EnumValueDef { id: "UnitSymbol.molPerm3", comment: "Concentration, The amount of substance concentration, (c), the amount of solvent in moles divided by the volume of solution in m³." },
9244 EnumValueDef { id: "UnitSymbol.molPermol", comment: "Concentration, Molar fraction, the ratio of the molar amount of a solute divided by the molar amount of the solution." },
9245 EnumValueDef { id: "UnitSymbol.molPerkg", comment: "Concentration, Molality, the amount of solute in moles and the amount of solvent in kilograms." },
9246 EnumValueDef { id: "UnitSymbol.sPers", comment: "Time, Ratio of time. Note: Users may need to supply a prefix such as ‘µ’ to show rates such as ‘µs/s’." },
9247 EnumValueDef { id: "UnitSymbol.HzPerHz", comment: "Frequency, rate of frequency change. Note: Users may need to supply a prefix such as ‘m’ to show rates such as ‘mHz/Hz’." },
9248 EnumValueDef { id: "UnitSymbol.VPerV", comment: "Voltage, ratio of voltages. Note: Users may need to supply a prefix such as ‘m’ to show rates such as ‘mV/V’." },
9249 EnumValueDef { id: "UnitSymbol.APerA", comment: "Current, ratio of amperages. Note: Users may need to supply a prefix such as ‘m’ to show rates such as ‘mA/A’." },
9250 EnumValueDef { id: "UnitSymbol.VPerVA", comment: "Power factor, PF, the ratio of the active power to the apparent power. Note: The sign convention used for power factor will differ between IEC meters and EEI (ANSI) meters. It is assumed that the data consumers understand the type of meter being used and agree on the sign convention in use at any given utility." },
9251 EnumValueDef { id: "UnitSymbol.rev", comment: "Amount of rotation, revolutions." },
9252 EnumValueDef { id: "UnitSymbol.kat", comment: "Catalytic activity, katal = mol / s." },
9253 EnumValueDef { id: "UnitSymbol.JPerkg", comment: "Specific energy, Joules / kg." },
9254 EnumValueDef { id: "UnitSymbol.m3Uncompensated", comment: "Volume, cubic metres, with the value uncompensated for weather effects." },
9255 EnumValueDef { id: "UnitSymbol.m3Compensated", comment: "Volume, cubic metres, with the value compensated for weather effects." },
9256 EnumValueDef { id: "UnitSymbol.WPerW", comment: "Signal Strength, ratio of power. Note: Users may need to supply a prefix such as ‘m’ to show rates such as ‘mW/W’." },
9257 EnumValueDef { id: "UnitSymbol.therm", comment: "Energy, therms." },
9258 EnumValueDef { id: "UnitSymbol.onePerm", comment: "Wavenumber, reciprocal metres, (1/m)." },
9259 EnumValueDef { id: "UnitSymbol.m3Perkg", comment: "Specific volume, cubic metres per kilogram, v." },
9260 EnumValueDef { id: "UnitSymbol.Pas", comment: "Dynamic viscosity, pascal seconds." },
9261 EnumValueDef { id: "UnitSymbol.Nm", comment: "Moment of force, newton metres." },
9262 EnumValueDef { id: "UnitSymbol.NPerm", comment: "Surface tension, newton per metre." },
9263 EnumValueDef { id: "UnitSymbol.radPers2", comment: "Angular acceleration, radians per second squared." },
9264 EnumValueDef { id: "UnitSymbol.JPerm3", comment: "Energy density, joules per cubic metre." },
9265 EnumValueDef { id: "UnitSymbol.VPerm", comment: "Electric field strength, volts per metre." },
9266 EnumValueDef { id: "UnitSymbol.CPerm3", comment: "Electric charge density, coulombs per cubic metre." },
9267 EnumValueDef { id: "UnitSymbol.CPerm2", comment: "Surface charge density, coulombs per square metre." },
9268 EnumValueDef { id: "UnitSymbol.FPerm", comment: "Permittivity, farads per metre." },
9269 EnumValueDef { id: "UnitSymbol.HPerm", comment: "Permeability, henrys per metre." },
9270 EnumValueDef { id: "UnitSymbol.JPermol", comment: "Molar energy, joules per mole." },
9271 EnumValueDef { id: "UnitSymbol.JPermolK", comment: "Molar entropy, molar heat capacity, joules per mole kelvin." },
9272 EnumValueDef { id: "UnitSymbol.CPerkg", comment: "Exposure (x rays), coulombs per kilogram." },
9273 EnumValueDef { id: "UnitSymbol.GyPers", comment: "Absorbed dose rate, grays per second." },
9274 EnumValueDef { id: "UnitSymbol.WPersr", comment: "Radiant intensity, watts per steradian." },
9275 EnumValueDef { id: "UnitSymbol.WPerm2sr", comment: "Radiance, watts per square metre steradian." },
9276 EnumValueDef { id: "UnitSymbol.katPerm3", comment: "Catalytic activity concentration, katals per cubic metre." },
9277 EnumValueDef { id: "UnitSymbol.d", comment: "Time in days, day = 24 h = 86400 s." },
9278 EnumValueDef { id: "UnitSymbol.anglemin", comment: "Plane angle, minutes." },
9279 EnumValueDef { id: "UnitSymbol.anglesec", comment: "Plane angle, seconds." },
9280 EnumValueDef { id: "UnitSymbol.ha", comment: "Area, hectares." },
9281 EnumValueDef { id: "UnitSymbol.tonne", comment: "Mass in tons, “tonne” or “metric ton” (1000 kg = 1 Mg)." },
9282 EnumValueDef { id: "UnitSymbol.bar", comment: "Pressure in bars, (1 bar = 100 kPa)." },
9283 EnumValueDef { id: "UnitSymbol.mmHg", comment: "Pressure, millimetres of mercury (1 mmHg is approximately 133.3 Pa)." },
9284 EnumValueDef { id: "UnitSymbol.M", comment: "Length, nautical miles (1 M = 1852 m)." },
9285 EnumValueDef { id: "UnitSymbol.kn", comment: "Speed, knots (1 kn = 1852/3600) m/s." },
9286 EnumValueDef { id: "UnitSymbol.Mx", comment: "Magnetic flux, maxwells (1 Mx = 10-8 Wb)." },
9287 EnumValueDef { id: "UnitSymbol.G", comment: "Magnetic flux density, gausses (1 G = 10-4 T)." },
9288 EnumValueDef { id: "UnitSymbol.Oe", comment: "Magnetic field in oersteds, (1 Oe = (103/4p) A/m)." },
9289 EnumValueDef { id: "UnitSymbol.Vh", comment: "Volt-hour, Volt hours." },
9290 EnumValueDef { id: "UnitSymbol.WPerA", comment: "Active power per current flow, watts per Ampere." },
9291 EnumValueDef { id: "UnitSymbol.onePerHz", comment: "Reciprocal of frequency (1/Hz)." },
9292 EnumValueDef { id: "UnitSymbol.VPerVAr", comment: "Power factor, PF, the ratio of the active power to the apparent power. Note: The sign convention used for power factor will differ between IEC meters and EEI (ANSI) meters. It is assumed that the data consumers understand the type of meter being used and agree on the sign convention in use at any given utility." },
9293 EnumValueDef { id: "UnitSymbol.ohmPerm", comment: "Electric resistance per length in ohms per metre ((V/A)/m)." },
9294 EnumValueDef { id: "UnitSymbol.kgPerJ", comment: "Weight per energy in kilograms per joule (kg/J). Note: multiplier “k” is included in this unit symbol for compatibility with IEC 61850-7-3." },
9295 EnumValueDef { id: "UnitSymbol.JPers", comment: "Energy rate in joules per second (J/s)." },
9296 ],
9297 },
9298 EnumDef {
9299 ns: "http://iec.ch/TC57/CIM100#",
9300 local: "Validity",
9301 comment: "Validity for MeasurementValue.",
9302 values: &[
9303 EnumValueDef { id: "Validity.GOOD", comment: "The value is marked good if no abnormal condition of the acquisition function or the information source is detected." },
9304 EnumValueDef { id: "Validity.QUESTIONABLE", comment: "The value is marked questionable if a supervision function detects an abnormal behaviour, however the value could still be valid. The client is responsible for determining whether or not values marked 'questionable' should be used." },
9305 EnumValueDef { id: "Validity.INVALID", comment: "The value is marked invalid when a supervision function recognises abnormal conditions of the acquisition function or the information source (missing or non-operating updating devices). The value is not defined under this condition. The mark invalid is used to indicate to the client that the value may be incorrect and shall not be used." },
9306 ],
9307 },
9308 EnumDef {
9309 ns: "http://iec.ch/TC57/CIM100#",
9310 local: "VsPpccControlKind",
9311 comment: "Types applicable to the control of real power and/or DC voltage by voltage source converter.",
9312 values: &[
9313 EnumValueDef { id: "VsPpccControlKind.pPcc", comment: "Control is real power at point of common coupling. The target value is provided by ACDCConverter.targetPpcc." },
9314 EnumValueDef { id: "VsPpccControlKind.udc", comment: "Control is DC voltage with target value provided by ACDCConverter.targetUdc." },
9315 EnumValueDef { id: "VsPpccControlKind.pPccAndUdcDroop", comment: "Control is active power at point of common coupling and local DC voltage, with the droop. Target values are provided by ACDCConverter.targetPpcc, ACDCConverter.targetUdc and VsConverter.droop." },
9316 EnumValueDef { id: "VsPpccControlKind.pPccAndUdcDroopWithCompensation", comment: "Control is active power at point of common coupling and compensated DC voltage, with the droop. Compensation factor is the resistance, as an approximation of the DC voltage of a common (real or virtual) node in the DC network. Targets are provided by ACDCConverter.targetPpcc, ACDCConverter.targetUdc, VsConverter.droop and VsConverter.droopCompensation." },
9317 EnumValueDef { id: "VsPpccControlKind.pPccAndUdcDroopPilot", comment: "Control is active power at point of common coupling and the pilot DC voltage, with the droop. The mode is used for Multi Terminal High Voltage DC (MTDC) systems where multiple HVDC Substations are connected to the HVDC transmission lines. The pilot voltage is then used to coordinate the control the DC voltage across the HVDC substations. Targets are provided by ACDCConverter.targetPpcc, ACDCConverter.targetUdc and VsConverter.droop." },
9318 EnumValueDef { id: "VsPpccControlKind.phasePcc", comment: "Control is phase at point of common coupling. Target is provided by VsConverter.targetPhasePcc." },
9319 ],
9320 },
9321 EnumDef {
9322 ns: "http://iec.ch/TC57/CIM100#",
9323 local: "VsQpccControlKind",
9324 comment: "Kind of reactive power control at point of common coupling for a voltage source converter.",
9325 values: &[
9326 EnumValueDef { id: "VsQpccControlKind.reactivePcc", comment: "Control is reactive power at point of common coupling. Target is provided by VsConverter.targetQpcc." },
9327 EnumValueDef { id: "VsQpccControlKind.voltagePcc", comment: "Control is voltage at point of common coupling. Target is provided by VsConverter.targetUpcc." },
9328 EnumValueDef { id: "VsQpccControlKind.powerFactorPcc", comment: "Control is power factor at point of common coupling. Target is provided by VsConverter.targetPowerFactorPcc." },
9329 EnumValueDef { id: "VsQpccControlKind.pulseWidthModulation", comment: "No explicit control. Pulse-modulation factor is directly set in magnitude (VsConverter.targetPWMfactor) and phase (VsConverter.targetPhasePcc)." },
9330 ],
9331 },
9332 EnumDef {
9333 ns: "http://iec.ch/TC57/CIM100#",
9334 local: "WindGenUnitKind",
9335 comment: "Kind of wind generating unit.",
9336 values: &[
9337 EnumValueDef { id: "WindGenUnitKind.offshore", comment: "The wind generating unit is located offshore." },
9338 EnumValueDef { id: "WindGenUnitKind.onshore", comment: "The wind generating unit is located onshore." },
9339 ],
9340 },
9341 EnumDef {
9342 ns: "http://iec.ch/TC57/CIM100#",
9343 local: "WindLookupTableFunctionKind",
9344 comment: "Function of the lookup table.",
9345 values: &[
9346 EnumValueDef { id: "WindLookupTableFunctionKind.prr", comment: "Power versus speed change (negative slip) lookup table (prr(deltaomega)). It is used for the rotor resistance control model, IEC 61400-27-1:2015, 5.6.5.3." },
9347 EnumValueDef { id: "WindLookupTableFunctionKind.omegap", comment: "Power vs. speed lookup table (omega(p)). It is used for the P control model type 3, IEC 61400-27-1:2015, 5.6.5.4." },
9348 EnumValueDef { id: "WindLookupTableFunctionKind.ipmax", comment: "Lookup table for voltage dependency of active current limits (ipmax(uWT)). It is used for the current limitation model, IEC 61400-27-1:2015, 5.6.5.8." },
9349 EnumValueDef { id: "WindLookupTableFunctionKind.iqmax", comment: "Lookup table for voltage dependency of reactive current limits (iqmax(uWT)). It is used for the current limitation model, IEC 61400-27-1:2015, 5.6.5.8." },
9350 EnumValueDef { id: "WindLookupTableFunctionKind.pwp", comment: "Power vs. frequency lookup table (pWPbias(f)). It is used for the wind power plant frequency and active power control model, IEC 61400-27-1:2015, Annex D." },
9351 EnumValueDef { id: "WindLookupTableFunctionKind.tcwdu", comment: "Crowbar duration versus voltage variation look-up table (TCW(du)). It is a case-dependent parameter. It is used for the type 3B generator set model, IEC 61400-27-1:2015, 5.6.3.3." },
9352 EnumValueDef { id: "WindLookupTableFunctionKind.tduwt", comment: "Lookup table to determine the duration of the power reduction after a voltage dip, depending on the size of the voltage dip (Td(uWT)). It is a type-dependent parameter. It is used for the pitch control power model, IEC 61400-27-1:2015, 5.6.5.1." },
9353 EnumValueDef { id: "WindLookupTableFunctionKind.qmaxp", comment: "Lookup table for active power dependency of reactive power maximum limit (qmaxp(p)). It is used for the QP and QU limitation model, IEC 61400-27-1:2015, 5.6.5.10." },
9354 EnumValueDef { id: "WindLookupTableFunctionKind.qminp", comment: "Lookup table for active power dependency of reactive power minimum limit (qminp(p)). It is used for the QP and QU limitation model, IEC 61400-27-1:2015, 5.6.5.10." },
9355 EnumValueDef { id: "WindLookupTableFunctionKind.qmaxu", comment: "Lookup table for voltage dependency of reactive power maximum limit (qmaxu(p)). It is used for the QP and QU limitation model, IEC 61400-27-1:2015, 5.6.5.10." },
9356 EnumValueDef { id: "WindLookupTableFunctionKind.qminu", comment: "Lookup table for voltage dependency of reactive power minimum limit (qminu(p)). It is used for the QP and QU limitation model, IEC 61400-27-1:2015, 5.6.5.10." },
9357 EnumValueDef { id: "WindLookupTableFunctionKind.tuover", comment: "Disconnection time versus over-voltage lookup table (Tuover(uWT)). It is used for the grid protection model, IEC 61400-27-1:2015, 5.6.6." },
9358 EnumValueDef { id: "WindLookupTableFunctionKind.tuunder", comment: "Disconnection time versus under-voltage lookup table (Tuunder(uWT)). It is used for the grid protection model, IEC 61400-27-1:2015, 5.6.6." },
9359 EnumValueDef { id: "WindLookupTableFunctionKind.tfover", comment: "Disconnection time versus over-frequency lookup table (Tfover(fWT)). It is used for the grid protection model, IEC 61400-27-1:2015, 5.6.6." },
9360 EnumValueDef { id: "WindLookupTableFunctionKind.tfunder", comment: "Disconnection time versus under-frequency lookup table (Tfunder(fWT)). It is used for the grid protection model, IEC 61400-27-1:2015, 5.6.6." },
9361 EnumValueDef { id: "WindLookupTableFunctionKind.qwp", comment: "Look up table for the UQ static mode (qWP(uerr)). It is used for the voltage and reactive power control model, IEC 61400-27-1:2015, Annex D." },
9362 ],
9363 },
9364 EnumDef {
9365 ns: "http://iec.ch/TC57/CIM100#",
9366 local: "WindPlantQcontrolModeKind",
9367 comment: "Reactive power/voltage controller mode.",
9368 values: &[
9369 EnumValueDef { id: "WindPlantQcontrolModeKind.reactivePower", comment: "Reactive power reference." },
9370 EnumValueDef { id: "WindPlantQcontrolModeKind.powerFactor", comment: "Power factor reference." },
9371 EnumValueDef { id: "WindPlantQcontrolModeKind.uqStatic", comment: "UQ static." },
9372 EnumValueDef { id: "WindPlantQcontrolModeKind.voltageControl", comment: "Voltage control." },
9373 ],
9374 },
9375 EnumDef {
9376 ns: "http://iec.ch/TC57/CIM100#",
9377 local: "WindQcontrolModeKind",
9378 comment: "General wind turbine Q control modes MqG.",
9379 values: &[
9380 EnumValueDef { id: "WindQcontrolModeKind.voltage", comment: "Voltage control (MqG equals 0)." },
9381 EnumValueDef { id: "WindQcontrolModeKind.reactivePower", comment: "Reactive power control (MqG equals 1)." },
9382 EnumValueDef { id: "WindQcontrolModeKind.openLoopReactivePower", comment: "Open loop reactive power control (only used with closed loop at plant level) (MqG equals 2)." },
9383 EnumValueDef { id: "WindQcontrolModeKind.powerFactor", comment: "Power factor control (MqG equals 3)." },
9384 EnumValueDef { id: "WindQcontrolModeKind.openLooppowerFactor", comment: "Open loop power factor control (MqG equals 4)." },
9385 ],
9386 },
9387 EnumDef {
9388 ns: "http://iec.ch/TC57/CIM100#",
9389 local: "WindUVRTQcontrolModeKind",
9390 comment: "UVRT Q control modes MqUVRT.",
9391 values: &[
9392 EnumValueDef { id: "WindUVRTQcontrolModeKind.mode0", comment: "Voltage-dependent reactive current injection (MqUVRT equals 0)." },
9393 EnumValueDef { id: "WindUVRTQcontrolModeKind.mode1", comment: "Reactive current injection controlled as the pre-fault value plus an additional voltage dependent reactive current injection (MqUVRT equals 1)." },
9394 EnumValueDef { id: "WindUVRTQcontrolModeKind.mode2", comment: "Reactive current injection controlled as the pre-fault value plus an additional voltage-dependent reactive current injection during fault, and as the pre-fault value plus an additional constant reactive current injection post fault (MqUVRT equals 2)." },
9395 ],
9396 },
9397 EnumDef {
9398 ns: "http://iec.ch/TC57/CIM100#",
9399 local: "WindingConnection",
9400 comment: "Winding connection type.",
9401 values: &[
9402 EnumValueDef { id: "WindingConnection.D", comment: "Delta." },
9403 EnumValueDef { id: "WindingConnection.Y", comment: "Wye." },
9404 EnumValueDef { id: "WindingConnection.Z", comment: "ZigZag." },
9405 EnumValueDef { id: "WindingConnection.Yn", comment: "Wye, with neutral brought out for grounding." },
9406 EnumValueDef { id: "WindingConnection.Zn", comment: "ZigZag, with neutral brought out for grounding." },
9407 EnumValueDef { id: "WindingConnection.A", comment: "Autotransformer common winding." },
9408 EnumValueDef { id: "WindingConnection.I", comment: "Independent winding, for single-phase connections." },
9409 ],
9410 },
9411];
9412
9413pub static SCHEMA: Schema = Schema { classes: CLASSES, profiles: PROFILES, namespaces: NAMESPACES, enums: ENUMS };