//! Gas-heater configuration types.
/// Gas-heater settings for one operating mode.
#[derive(Clone, Copy, Debug, Eq, PartialEq)]
pub enum HeaterConfiguration<'a> {
/// One heater temperature and duration for forced mode.
Forced {
/// Whether gas measurement and the heater are enabled.
enabled: bool,
/// Target heater temperature in degrees Celsius (capped to 400 °C).
temperature_celsius: u16,
/// Heater duration in milliseconds.
duration_ms: u16,
},
/// A heater profile for sequential mode.
Sequential {
/// Whether gas measurement and the heater are enabled.
enabled: bool,
/// Target temperatures in degrees Celsius, one to ten entries.
temperatures_celsius: &'a [u16],
/// Heater durations in milliseconds, one per temperature.
durations_ms: &'a [u16],
},
/// A heater profile for parallel mode.
Parallel {
/// Whether gas measurement and the heater are enabled.
enabled: bool,
/// Target temperatures in degrees Celsius, one to ten entries.
temperatures_celsius: &'a [u16],
/// Per-step TPHG repetition multipliers, one per temperature.
///
/// In parallel mode Bosch defines each `GAS_WAITx` byte as a raw
/// repetition multiplier, not as milliseconds. A value of zero is the
/// documented special case: skip the shared wait and execute one TPHG
/// conversion.
repetition_multipliers: &'a [u8],
/// Shared heater duration in milliseconds; must be non-zero.
shared_duration_ms: u16,
},
}
impl HeaterConfiguration<'_> {
/// Operating mode required by this heater configuration.
#[must_use]
pub const fn mode(&self) -> crate::OperationMode {
match self {
Self::Forced { .. } => crate::OperationMode::Forced,
Self::Sequential { .. } => crate::OperationMode::Sequential,
Self::Parallel { .. } => crate::OperationMode::Parallel,
}
}
#[cfg(any(feature = "blocking", feature = "async"))]
pub(crate) const fn enabled(&self) -> bool {
match self {
Self::Forced { enabled, .. }
| Self::Sequential { enabled, .. }
| Self::Parallel { enabled, .. } => *enabled,
}
}
}
/// Raw heater profile registers read back from the sensor.
#[derive(Clone, Copy, Debug, Default, Eq, PartialEq)]
pub struct HeaterRegisters {
/// Raw `IDAC_HEAT0..9` values.
pub current: [u8; 10],
/// Raw `RES_HEAT0..9` values.
pub resistance: [u8; 10],
/// Raw `GAS_WAIT0..9` values.
pub gas_wait: [u8; 10],
/// Raw shared-heater-duration register.
pub shared_duration: u8,
}
/// Complete raw gas-heater control and profile readback.
#[derive(Clone, Copy, Debug, Default, Eq, PartialEq)]
pub struct HeaterConfigurationReadback {
/// All current-DAC, heater-resistance, gas-wait, and shared-duration
/// profile registers.
pub registers: HeaterRegisters,
/// Exact `CTRL_GAS_0` register value.
pub control_gas_0: u8,
/// Exact `CTRL_GAS_1` register value.
pub control_gas_1: u8,
}
impl HeaterConfigurationReadback {
/// Whether the heater-control bit enables the heater.
#[must_use]
pub const fn heater_enabled(self) -> bool {
self.control_gas_0 & 0x08 == 0
}
/// Raw two-bit `run_gas` field.
#[must_use]
pub const fn run_gas(self) -> u8 {
(self.control_gas_1 >> 4) & 0x03
}
/// Raw four-bit `nb_conv` profile-length field.
///
/// Bosch programs zero for a forced-mode one-step conversion and the
/// configured step count for sequential/parallel profiles.
#[must_use]
pub const fn profile_length(self) -> u8 {
self.control_gas_1 & 0x0f
}
}
/// Environmental, operating-mode, and gas-heater register readback.
#[derive(Clone, Copy, Debug, Eq, PartialEq)]
pub struct SensorConfigurationReadback {
/// Current sensor operating mode.
pub operation_mode: crate::OperationMode,
/// Current temperature, pressure, humidity, filter, and standby settings.
pub environmental: crate::Configuration,
/// Current gas-heater control and profile registers.
pub heater: HeaterConfigurationReadback,
}