<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet href="dlt_messages.xsl" type="text/xsl" ?>
<fx:FIBEX xmlns:ho="http://www.asam.net/xml" xmlns:fx="http://www.asam.net/xml/fbx">
<fx:PROJECT ID="adlt-non-verbose-1">
<ho:SHORT-NAME>adlt non verbose test fibex 1</ho:SHORT-NAME>
</fx:PROJECT>
<fx:ELEMENTS>
<fx:ECUS>
<fx:ECU ID="Ecu1">
<ho:SHORT-NAME>Ecu1</ho:SHORT-NAME>
<fx:MANUFACTURER-EXTENSION>
<SW_VERSION>1.0.0</SW_VERSION>
<APPLICATIONS>
<APPLICATION>
<APPLICATION_ID>HLD</APPLICATION_ID>
<APPLICATION_DESCRIPTION>Description for apid HLD</APPLICATION_DESCRIPTION>
<CONTEXTS>
<CONTEXT>
<CONTEXT_ID>ERR</CONTEXT_ID>
<CONTEXT_DESCRIPTION>Description for apid:context HLD:ERR</CONTEXT_DESCRIPTION>
</CONTEXT>
<CONTEXT>
<CONTEXT_ID>MAIN</CONTEXT_ID>
<CONTEXT_DESCRIPTION>Description for apid:context HLD:MAIN</CONTEXT_DESCRIPTION>
</CONTEXT>
</CONTEXTS>
</APPLICATION>
</APPLICATIONS>
</fx:MANUFACTURER-EXTENSION>
</fx:ECU>
</fx:ECUS>
<fx:PDUS>
<fx:PDU ID="PAYLOAD_805834672_0_DESCR">
<ho:SHORT-NAME>FooError_Process</ho:SHORT-NAME>
<ho:DESC>LLD error status changed, lldErrorStatus=</ho:DESC>
<fx:BYTE-LENGTH>0</fx:BYTE-LENGTH>
<fx:PDU-TYPE>OTHER</fx:PDU-TYPE>
</fx:PDU>
<fx:PDU ID="PAYLOAD_805834672_1">
<ho:SHORT-NAME>lldErrorStatus</ho:SHORT-NAME>
<fx:BYTE-LENGTH>4</fx:BYTE-LENGTH>
<fx:PDU-TYPE>OTHER</fx:PDU-TYPE>
<fx:SIGNAL-INSTANCES>
<fx:SIGNAL-INSTANCE ID="S_805834672_1">
<fx:SEQUENCE-NUMBER>0</fx:SEQUENCE-NUMBER>
<fx:SIGNAL-REF ID-REF="S_UINT32"/>
</fx:SIGNAL-INSTANCE>
</fx:SIGNAL-INSTANCES>
</fx:PDU>
<fx:PDU ID="PAYLOAD_805834673_0_DESCR">
<ho:SHORT-NAME>FooError_Set</ho:SHORT-NAME>
<ho:DESC>DTC set but env data was not yet fetched, lldErrorStatus=</ho:DESC>
<fx:BYTE-LENGTH>0</fx:BYTE-LENGTH>
<fx:PDU-TYPE>OTHER</fx:PDU-TYPE>
</fx:PDU>
<fx:PDU ID="PAYLOAD_805834673_1">
<ho:SHORT-NAME>newEnvData.lldErrorStatus</ho:SHORT-NAME>
<fx:BYTE-LENGTH>4</fx:BYTE-LENGTH>
<fx:PDU-TYPE>OTHER</fx:PDU-TYPE>
<fx:SIGNAL-INSTANCES>
<fx:SIGNAL-INSTANCE ID="S_805834673_1">
<fx:SEQUENCE-NUMBER>0</fx:SEQUENCE-NUMBER>
<fx:SIGNAL-REF ID-REF="S_UINT32"/>
</fx:SIGNAL-INSTANCE>
</fx:SIGNAL-INSTANCES>
</fx:PDU>
<fx:PDU ID="PAYLOAD_805834673_2_DESCR">
<ho:SHORT-NAME>FooError_Set</ho:SHORT-NAME>
<ho:DESC>, lldStatus=</ho:DESC>
<fx:BYTE-LENGTH>0</fx:BYTE-LENGTH>
<fx:PDU-TYPE>OTHER</fx:PDU-TYPE>
</fx:PDU>
<fx:PDU ID="PAYLOAD_805834673_3">
<ho:SHORT-NAME>newEnvData.lldStatus</ho:SHORT-NAME>
<fx:BYTE-LENGTH>4</fx:BYTE-LENGTH>
<fx:PDU-TYPE>OTHER</fx:PDU-TYPE>
<fx:SIGNAL-INSTANCES>
<fx:SIGNAL-INSTANCE ID="S_805834673_3">
<fx:SEQUENCE-NUMBER>0</fx:SEQUENCE-NUMBER>
<fx:SIGNAL-REF ID-REF="S_SINT32"/>
</fx:SIGNAL-INSTANCE>
</fx:SIGNAL-INSTANCES>
</fx:PDU>
<fx:PDU ID="PAYLOAD_805834673_4_DESCR">
<ho:SHORT-NAME>FooError_Set</ho:SHORT-NAME>
<ho:DESC>, lldBcklTemp=</ho:DESC>
<fx:BYTE-LENGTH>0</fx:BYTE-LENGTH>
<fx:PDU-TYPE>OTHER</fx:PDU-TYPE>
</fx:PDU>
<fx:PDU ID="PAYLOAD_805834673_5">
<ho:SHORT-NAME>newEnvData.lldBcklTemp</ho:SHORT-NAME>
<fx:BYTE-LENGTH>2</fx:BYTE-LENGTH>
<fx:PDU-TYPE>OTHER</fx:PDU-TYPE>
<fx:SIGNAL-INSTANCES>
<fx:SIGNAL-INSTANCE ID="S_805834673_5">
<fx:SEQUENCE-NUMBER>0</fx:SEQUENCE-NUMBER>
<fx:SIGNAL-REF ID-REF="S_UINT16"/>
</fx:SIGNAL-INSTANCE>
</fx:SIGNAL-INSTANCES>
</fx:PDU>
<fx:PDU ID="PAYLOAD_805834673_6_DESCR">
<ho:SHORT-NAME>FooError_Set</ho:SHORT-NAME>
<ho:DESC>, lldVccVoltage=</ho:DESC>
<fx:BYTE-LENGTH>0</fx:BYTE-LENGTH>
<fx:PDU-TYPE>OTHER</fx:PDU-TYPE>
</fx:PDU>
<fx:PDU ID="PAYLOAD_805834673_7">
<ho:SHORT-NAME>newEnvData.lldVccVoltage</ho:SHORT-NAME>
<fx:BYTE-LENGTH>1</fx:BYTE-LENGTH>
<fx:PDU-TYPE>OTHER</fx:PDU-TYPE>
<fx:SIGNAL-INSTANCES>
<fx:SIGNAL-INSTANCE ID="S_805834673_7">
<fx:SEQUENCE-NUMBER>0</fx:SEQUENCE-NUMBER>
<fx:SIGNAL-REF ID-REF="S_UINT8"/>
</fx:SIGNAL-INSTANCE>
</fx:SIGNAL-INSTANCES>
</fx:PDU>
<fx:PDU ID="PAYLOAD_805312382_0_DESCR">
<ho:SHORT-NAME>FooMain_FooStateMachine</ho:SHORT-NAME>
<ho:DESC>FooStateMachine, Enter ON State</ho:DESC>
<fx:BYTE-LENGTH>0</fx:BYTE-LENGTH>
<fx:PDU-TYPE>OTHER</fx:PDU-TYPE>
</fx:PDU>
</fx:PDUS>
<fx:FRAMES>
<fx:FRAME ID="ID_805834673">
<ho:SHORT-NAME>FooError_Set</ho:SHORT-NAME>
<fx:BYTE-LENGTH>11</fx:BYTE-LENGTH>
<fx:FRAME-TYPE>OTHER</fx:FRAME-TYPE>
<fx:PDU-INSTANCES>
<fx:PDU-INSTANCE ID="PDU_805834673_0_DESCR">
<fx:PDU-REF ID-REF="PAYLOAD_805834673_0_DESCR"/>
<fx:SEQUENCE-NUMBER>0</fx:SEQUENCE-NUMBER>
</fx:PDU-INSTANCE>
<fx:PDU-INSTANCE ID="PDU_805834673_1">
<fx:PDU-REF ID-REF="PAYLOAD_805834673_1"/>
<fx:SEQUENCE-NUMBER>1</fx:SEQUENCE-NUMBER>
</fx:PDU-INSTANCE>
<fx:PDU-INSTANCE ID="PDU_805834673_2_DESCR">
<fx:PDU-REF ID-REF="PAYLOAD_805834673_2_DESCR"/>
<fx:SEQUENCE-NUMBER>2</fx:SEQUENCE-NUMBER>
</fx:PDU-INSTANCE>
<fx:PDU-INSTANCE ID="PDU_805834673_3">
<fx:PDU-REF ID-REF="PAYLOAD_805834673_3"/>
<fx:SEQUENCE-NUMBER>3</fx:SEQUENCE-NUMBER>
</fx:PDU-INSTANCE>
<fx:PDU-INSTANCE ID="PDU_805834673_4_DESCR">
<fx:PDU-REF ID-REF="PAYLOAD_805834673_4_DESCR"/>
<fx:SEQUENCE-NUMBER>4</fx:SEQUENCE-NUMBER>
</fx:PDU-INSTANCE>
<fx:PDU-INSTANCE ID="PDU_805834673_5">
<fx:PDU-REF ID-REF="PAYLOAD_805834673_5"/>
<fx:SEQUENCE-NUMBER>5</fx:SEQUENCE-NUMBER>
</fx:PDU-INSTANCE>
<fx:PDU-INSTANCE ID="PDU_805834673_6_DESCR">
<fx:PDU-REF ID-REF="PAYLOAD_805834673_6_DESCR"/>
<fx:SEQUENCE-NUMBER>6</fx:SEQUENCE-NUMBER>
</fx:PDU-INSTANCE>
<fx:PDU-INSTANCE ID="PDU_805834673_7">
<fx:PDU-REF ID-REF="PAYLOAD_805834673_7"/>
<fx:SEQUENCE-NUMBER>7</fx:SEQUENCE-NUMBER>
</fx:PDU-INSTANCE>
</fx:PDU-INSTANCES>
<fx:MANUFACTURER-EXTENSION>
<MESSAGE_TYPE>DLT_TYPE_LOG</MESSAGE_TYPE>
<MESSAGE_INFO>DLT_LOG_WARN</MESSAGE_INFO>
<APPLICATION_ID>HLD</APPLICATION_ID>
<CONTEXT_ID>ERR</CONTEXT_ID>
<MESSAGE_SOURCE_FILE>FooError.c</MESSAGE_SOURCE_FILE>
<MESSAGE_LINE_NUMBER>42</MESSAGE_LINE_NUMBER>
</fx:MANUFACTURER-EXTENSION>
</fx:FRAME>
<fx:FRAME ID="ID_805312382">
<ho:SHORT-NAME>FooMain_FooStateMachine</ho:SHORT-NAME>
<fx:BYTE-LENGTH>0</fx:BYTE-LENGTH>
<fx:FRAME-TYPE>OTHER</fx:FRAME-TYPE>
<fx:PDU-INSTANCES>
<fx:PDU-INSTANCE ID="PDU_805312382_0_DESCR">
<fx:PDU-REF ID-REF="PAYLOAD_805312382_0_DESCR"/>
<fx:SEQUENCE-NUMBER>0</fx:SEQUENCE-NUMBER>
</fx:PDU-INSTANCE>
</fx:PDU-INSTANCES>
<fx:MANUFACTURER-EXTENSION>
<MESSAGE_TYPE>DLT_TYPE_LOG</MESSAGE_TYPE>
<MESSAGE_INFO>DLT_LOG_DEBUG</MESSAGE_INFO>
<APPLICATION_ID>HLD</APPLICATION_ID>
<CONTEXT_ID>MAIN</CONTEXT_ID>
<MESSAGE_SOURCE_FILE>FooMain_Statemachines.c</MESSAGE_SOURCE_FILE>
<MESSAGE_LINE_NUMBER>111</MESSAGE_LINE_NUMBER>
</fx:MANUFACTURER-EXTENSION>
</fx:FRAME>
</fx:FRAMES>
</fx:ELEMENTS>
</fx:FIBEX>