pub struct SetMonitoringLevelRequest {
pub severity: i64,
pub custom_data: Option<CustomData>,
}Fields§
§severity: i64The Charging Station SHALL only report events with a severity number lower than or equal to this severity. The severity range is 0-9, with 0 as the highest and 9 as the lowest severity level. The severity levels have the following meaning: + 0-Danger + Indicates lives are potentially in danger. Urgent attention is needed and action should be taken immediately. + 1-Hardware Failure + Indicates that the Charging Station is unable to continue regular operations due to Hardware issues. Action is required. + 2-System Failure + Indicates that the Charging Station is unable to continue regular operations due to software or minor hardware issues. Action is required. + 3-Critical + Indicates a critical error. Action is required. + 4-Error + Indicates a non-urgent error. Action is required. + 5-Alert + Indicates an alert event. Default severity for any type of monitoring event. + 6-Warning + Indicates a warning event. Action may be required. + 7-Notice + Indicates an unusual event. No immediate action is required. + 8-Informational + Indicates a regular operational event. May be used for reporting, measuring throughput, etc. No action is required. + 9-Debug + Indicates information useful to developers for debugging, not useful during operations.
custom_data: Option<CustomData>