pub struct VsConverter {Show 15 fields
pub base: ACDCConverter,
pub capability_curve: Option<MridRef>,
pub delta: Option<f64>,
pub droop: Option<f64>,
pub droop_compensation: Option<f64>,
pub max_modulation_index: Option<f64>,
pub p_pcc_control: Option<UriRef>,
pub q_pcc_control: Option<UriRef>,
pub q_share: Option<f64>,
pub target_pw_mfactor: Option<f64>,
pub target_phase_pcc: Option<f64>,
pub target_power_factor_pcc: Option<f64>,
pub target_qpcc: Option<f64>,
pub target_upcc: Option<f64>,
pub uv: Option<f64>,
}Expand description
DC side of the voltage source converter (VSC).
Fields§
§base: ACDCConverter§capability_curve: Option<MridRef>Capability curve of this converter.
delta: Option<f64>Angle between VsConverter.uv and ACDCConverter.uc. It is converter’s state variable used in power flow. The attribute shall be a positive value or zero.
droop: Option<f64>Droop constant. The pu value is obtained as D [kV/MW] x Sb / Ubdc. The attribute shall be a positive value.
droop_compensation: Option<f64>Compensation constant. Used to compensate for voltage drop when controlling voltage at a distant bus. The attribute shall be a positive value.
max_modulation_index: Option<f64>The maximum quotient between the AC converter voltage (Uc) and DC voltage (Ud). A factor typically less than 1. It is converter’s configuration data used in power flow.
p_pcc_control: Option<UriRef>Kind of control of real power and/or DC voltage.
q_pcc_control: Option<UriRef>Kind of reactive power control.
Reactive power sharing factor among parallel converters on Uac control. The attribute shall be a positive value or zero.
target_pw_mfactor: Option<f64>Magnitude of pulse-modulation factor. The attribute shall be a positive value.
target_phase_pcc: Option<f64>Phase target at AC side, at point of common coupling. The attribute shall be a positive value.
target_power_factor_pcc: Option<f64>Power factor target at the AC side, at point of common coupling. The attribute shall be a positive value.
target_qpcc: Option<f64>Reactive power injection target in AC grid, at point of common coupling. Load sign convention is used, i.e. positive sign means flow out from a node.
target_upcc: Option<f64>Voltage target in AC grid, at point of common coupling. The attribute shall be a positive value.
uv: Option<f64>Line-to-line voltage on the valve side of the converter transformer. It is converter’s state variable, result from power flow. The attribute shall be a positive value.
Implementations§
Source§impl VsConverter
impl VsConverter
pub fn from_block(b: &RdfBlock) -> Self
Trait Implementations§
Source§impl CimElement for VsConverter
impl CimElement for VsConverter
Source§impl Clone for VsConverter
impl Clone for VsConverter
Source§fn clone(&self) -> VsConverter
fn clone(&self) -> VsConverter
1.0.0 (const: unstable) · Source§fn clone_from(&mut self, source: &Self)
fn clone_from(&mut self, source: &Self)
source. Read more