pub struct ACDCTerminal {
pub base: IdentifiedObject,
pub bus_name_marker: Option<MridRef>,
pub connected: Option<bool>,
pub sequence_number: Option<i64>,
}Expand description
An electrical connection point (AC or DC) to a piece of conducting equipment. Terminals are connected at physical connection points called connectivity nodes.
Fields§
§base: IdentifiedObject§bus_name_marker: Option<MridRef>The bus name marker used to name the bus (topological node).
connected: Option<bool>The connected status is related to a bus-branch model and the topological node to terminal relation. True implies the terminal is connected to the related topological node and false implies it is not. In a bus-branch model, the connected status is used to tell if equipment is disconnected without having to change the connectivity described by the topological node to terminal relation. A valid case is that conducting equipment can be connected in one end and open in the other. In particular for an AC line segment, where the reactive line charging can be significant, this is a relevant case.
sequence_number: Option<i64>The orientation of the terminal connections for a multiple terminal conducting equipment. The sequence numbering starts with 1 and additional terminals should follow in increasing order. The first terminal is the ‘starting point’ for a two terminal branch.
Implementations§
Source§impl ACDCTerminal
impl ACDCTerminal
pub fn from_block(b: &RdfBlock) -> Self
Trait Implementations§
Source§impl CimElement for ACDCTerminal
impl CimElement for ACDCTerminal
Source§impl Clone for ACDCTerminal
impl Clone for ACDCTerminal
Source§fn clone(&self) -> ACDCTerminal
fn clone(&self) -> ACDCTerminal
1.0.0 (const: unstable) · Source§fn clone_from(&mut self, source: &Self)
fn clone_from(&mut self, source: &Self)
source. Read more