pub struct WindContQIEC {Show 24 fields
pub base: IdentifiedObject,
pub iqh1: Option<f64>,
pub iqmax: Option<f64>,
pub iqmin: Option<f64>,
pub iqpost: Option<f64>,
pub kiq: Option<f64>,
pub kiu: Option<f64>,
pub kpq: Option<f64>,
pub kpu: Option<f64>,
pub kqv: Option<f64>,
pub rdroop: Option<f64>,
pub tpfiltq: Option<f64>,
pub tpost: Option<f64>,
pub tqord: Option<f64>,
pub tufiltq: Option<f64>,
pub udb1: Option<f64>,
pub udb2: Option<f64>,
pub umax: Option<f64>,
pub umin: Option<f64>,
pub uqdip: Option<f64>,
pub uref0: Option<f64>,
pub wind_qcontrol_modes_type: Option<UriRef>,
pub wind_uvrt_qcontrol_modes_type: Option<UriRef>,
pub xdroop: Option<f64>,
}Expand description
Q control model. Reference: IEC 61400-27-1:2015, 5.6.5.7.
Fields§
§base: IdentifiedObject§iqh1: Option<f64>Maximum reactive current injection during dip (iqh1). It is a type-dependent parameter.
iqmax: Option<f64>Maximum reactive current injection (iqmax) (> WindContQIEC.iqmin). It is a type-dependent parameter.
iqmin: Option<f64>Minimum reactive current injection (iqmin) (< WindContQIEC.iqmax). It is a type-dependent parameter.
iqpost: Option<f64>Post fault reactive current injection (iqpost). It is a project-dependent parameter.
kiq: Option<f64>Reactive power PI controller integration gain (KI,q). It is a type-dependent parameter.
kiu: Option<f64>Voltage PI controller integration gain (KI,u). It is a type-dependent parameter.
kpq: Option<f64>Reactive power PI controller proportional gain (KP,q). It is a type-dependent parameter.
kpu: Option<f64>Voltage PI controller proportional gain (KP,u). It is a type-dependent parameter.
kqv: Option<f64>Voltage scaling factor for UVRT current (Kqv). It is a project-dependent parameter.
rdroop: Option<f64>Resistive component of voltage drop impedance (rdroop) (>= 0). It is a project-dependent parameter.
tpfiltq: Option<f64>Power measurement filter time constant (Tpfiltq) (>= 0). It is a type-dependent parameter.
tpost: Option<f64>Length of time period where post fault reactive power is injected (Tpost) (>= 0). It is a project-dependent parameter.
tqord: Option<f64>Time constant in reactive power order lag (Tqord) (>= 0). It is a type-dependent parameter.
tufiltq: Option<f64>Voltage measurement filter time constant (Tufiltq) (>= 0). It is a type-dependent parameter.
udb1: Option<f64>Voltage deadband lower limit (udb1). It is a type-dependent parameter.
udb2: Option<f64>Voltage deadband upper limit (udb2). It is a type-dependent parameter.
umax: Option<f64>Maximum voltage in voltage PI controller integral term (umax) (> WindContQIEC.umin). It is a type-dependent parameter.
umin: Option<f64>Minimum voltage in voltage PI controller integral term (umin) (< WindContQIEC.umax). It is a type-dependent parameter.
uqdip: Option<f64>Voltage threshold for UVRT detection in Q control (uqdip). It is a type-dependent parameter.
uref0: Option<f64>User-defined bias in voltage reference (uref0). It is a case-dependent parameter.
wind_qcontrol_modes_type: Option<UriRef>Types of general wind turbine Q control modes (MqG). It is a project-dependent parameter.
wind_uvrt_qcontrol_modes_type: Option<UriRef>Types of UVRT Q control modes (MqUVRT). It is a project-dependent parameter.
xdroop: Option<f64>Inductive component of voltage drop impedance (xdroop) (>= 0). It is a project-dependent parameter.
Implementations§
Source§impl WindContQIEC
impl WindContQIEC
pub fn from_block(b: &RdfBlock) -> Self
Trait Implementations§
Source§impl CimElement for WindContQIEC
impl CimElement for WindContQIEC
Source§impl Clone for WindContQIEC
impl Clone for WindContQIEC
Source§fn clone(&self) -> WindContQIEC
fn clone(&self) -> WindContQIEC
1.0.0 (const: unstable) · Source§fn clone_from(&mut self, source: &Self)
fn clone_from(&mut self, source: &Self)
source. Read more