pub struct WindContPType3IEC {Show 24 fields
pub base: IdentifiedObject,
pub dpmax: Option<f64>,
pub dprefmax: Option<f64>,
pub dprefmin: Option<f64>,
pub dthetamax: Option<f64>,
pub dthetamaxuvrt: Option<f64>,
pub kdtd: Option<f64>,
pub kip: Option<f64>,
pub kpp: Option<f64>,
pub mpuvrt: Option<bool>,
pub omegadtd: Option<f64>,
pub omegaoffset: Option<f64>,
pub pdtdmax: Option<f64>,
pub tdvs: Option<f64>,
pub thetaemin: Option<f64>,
pub thetauscale: Option<f64>,
pub tomegafiltp3: Option<f64>,
pub tomegaref: Option<f64>,
pub tpfiltp3: Option<f64>,
pub tpord: Option<f64>,
pub tufiltp3: Option<f64>,
pub udvs: Option<f64>,
pub updip: Option<f64>,
pub zeta: Option<f64>,
}Expand description
P control model type 3. Reference: IEC 61400-27-1:2015, 5.6.5.4.
Fields§
§base: IdentifiedObject§dpmax: Option<f64>Maximum wind turbine power ramp rate (dpmax). It is a type-dependent parameter.
dprefmax: Option<f64>Maximum ramp rate of wind turbine reference power (dprefmax). It is a project-dependent parameter.
dprefmin: Option<f64>Minimum ramp rate of wind turbine reference power (dprefmin). It is a project-dependent parameter.
dthetamax: Option<f64>Ramp limitation of torque, required in some grid codes (dtmax). It is a project-dependent parameter.
dthetamaxuvrt: Option<f64>Limitation of torque rise rate during UVRT (dthetamaxUVRT). It is a project-dependent parameter.
kdtd: Option<f64>Gain for active drive train damping (KDTD). It is a type-dependent parameter.
kip: Option<f64>PI controller integration parameter (KIp). It is a type-dependent parameter.
kpp: Option<f64>PI controller proportional gain (KPp). It is a type-dependent parameter.
mpuvrt: Option<bool>Enable UVRT power control mode (MpUVRT). It is a project-dependent parameter. true = voltage control (1 in the IEC model) false = reactive power control (0 in the IEC model).
omegadtd: Option<f64>Active drive train damping frequency (omegaDTD). It can be calculated from two mass model parameters. It is a type-dependent parameter.
omegaoffset: Option<f64>Offset to reference value that limits controller action during rotor speed changes (omegaoffset). It is a case-dependent parameter.
pdtdmax: Option<f64>Maximum active drive train damping power (pDTDmax). It is a type-dependent parameter.
tdvs: Option<f64>Time delay after deep voltage sags (TDVS) (>= 0). It is a project-dependent parameter.
thetaemin: Option<f64>Minimum electrical generator torque (temin). It is a type-dependent parameter.
thetauscale: Option<f64>Voltage scaling factor of reset-torque (tuscale). It is a project-dependent parameter.
tomegafiltp3: Option<f64>Filter time constant for generator speed measurement (Tomegafiltp3) (>= 0). It is a type-dependent parameter.
tomegaref: Option<f64>Time constant in speed reference filter (Tomega,ref) (>= 0). It is a type-dependent parameter.
tpfiltp3: Option<f64>Filter time constant for power measurement (Tpfiltp3) (>= 0). It is a type-dependent parameter.
tpord: Option<f64>Time constant in power order lag (Tpord). It is a type-dependent parameter.
tufiltp3: Option<f64>Filter time constant for voltage measurement (Tufiltp3) (>= 0). It is a type-dependent parameter.
udvs: Option<f64>Voltage limit for hold UVRT status after deep voltage sags (uDVS). It is a project-dependent parameter.
updip: Option<f64>Voltage dip threshold for P-control (uPdip). Part of turbine control, often different (e.g 0.8) from converter thresholds. It is a project-dependent parameter.
zeta: Option<f64>Coefficient for active drive train damping (zeta). It is a type-dependent parameter.
Implementations§
Source§impl WindContPType3IEC
impl WindContPType3IEC
pub fn from_block(b: &RdfBlock) -> Self
Trait Implementations§
Source§impl CimElement for WindContPType3IEC
impl CimElement for WindContPType3IEC
Source§impl Clone for WindContPType3IEC
impl Clone for WindContPType3IEC
Source§fn clone(&self) -> WindContPType3IEC
fn clone(&self) -> WindContPType3IEC
1.0.0 (const: unstable) · Source§fn clone_from(&mut self, source: &Self)
fn clone_from(&mut self, source: &Self)
source. Read more