pub struct LoadMotor {
Show 15 fields pub base: IdentifiedObject, pub load_aggregate: Option<MridRef>, pub d: Option<f64>, pub h: Option<f64>, pub lfac: Option<f64>, pub lp: Option<f64>, pub lpp: Option<f64>, pub ls: Option<f64>, pub pfrac: Option<f64>, pub ra: Option<f64>, pub tbkr: Option<f64>, pub tpo: Option<f64>, pub tppo: Option<f64>, pub tv: Option<f64>, pub vt: Option<f64>,
}
Expand description

Aggregate induction motor load. This model is used to represent a fraction of an ordinary load as ‘induction motor load’. It allows a load that is treated as an ordinary constant power in power flow analysis to be represented by an induction motor in dynamic simulation. This model is intended for representation of aggregations of many motors dispersed through a load represented at a high voltage bus but where there is no information on the characteristics of individual motors. Either a ‘one-cage’ or ‘two-cage’ model of the induction machine can be modelled. Magnetic saturation is not modelled. This model treats a fraction of the constant power part of a load as a motor. During initialisation, the initial power drawn by the motor is set equal to Pfrac times the constant P part of the static load. The remainder of the load is left as a static load. The reactive power demand of the motor is calculated during initialisation as a function of voltage at the load bus. This reactive power demand can be less than or greater than the constant Q component of the load. If the motor’s reactive demand is greater than the constant Q component of the load, the model inserts a shunt capacitor at the terminal of the motor to bring its reactive demand down to equal the constant Q reactive load. If an induction motor load model and a static load model are both present for a load, the motor Pfrac is assumed to be subtracted from the power flow constant P load before the static load model is applied. The remainder of the load, if any, is then represented by the static load model.

Fields§

§base: IdentifiedObject§load_aggregate: Option<MridRef>

Aggregate load to which this aggregate motor (dynamic) load belongs.

§d: Option<f64>

Damping factor (D). Unit = delta P/delta speed. Typical value = 2.

§h: Option<f64>

Inertia constant (H) (>= 0). Typical value = 0,4.

§lfac: Option<f64>

Loading factor (Lfac). The ratio of initial P to motor MVA base. Typical value = 0,8.

§lp: Option<f64>

Transient reactance (Lp). Typical value = 0,15.

§lpp: Option<f64>

Subtransient reactance (Lpp). Typical value = 0,15.

§ls: Option<f64>

Synchronous reactance (Ls). Typical value = 3,2.

§pfrac: Option<f64>

Fraction of constant-power load to be represented by this motor model (Pfrac) (>= 0,0 and <= 1,0). Typical value = 0,3.

§ra: Option<f64>

Stator resistance (Ra). Typical value = 0.

§tbkr: Option<f64>

Circuit breaker operating time (Tbkr) (>= 0). Typical value = 0,08.

§tpo: Option<f64>

Transient rotor time constant (Tpo) (>= 0). Typical value = 1.

§tppo: Option<f64>

Subtransient rotor time constant (Tppo) (>= 0). Typical value = 0,02.

§tv: Option<f64>

Voltage trip pickup time (Tv) (>= 0). Typical value = 0,1.

§vt: Option<f64>

Voltage threshold for tripping (Vt). Typical value = 0,7.

Implementations§

Trait Implementations§

Source§

impl CimElement for LoadMotor

Source§

fn mrid(&self) -> &str

Source§

fn type_name(&self) -> &'static str

Source§

fn as_any(&self) -> &dyn Any

Source§

fn to_json_value(&self) -> Value

Source§

fn to_block(&self) -> RdfBlock

Source§

impl Clone for LoadMotor

Source§

fn clone(&self) -> LoadMotor

Returns a duplicate of the value. Read more
1.0.0 (const: unstable) · Source§

fn clone_from(&mut self, source: &Self)

Performs copy-assignment from source. Read more
Source§

impl Debug for LoadMotor

Source§

fn fmt(&self, f: &mut Formatter<'_>) -> Result

Formats the value using the given formatter. Read more
Source§

impl Default for LoadMotor

Source§

fn default() -> LoadMotor

Returns the “default value” for a type. Read more
Source§

impl<'de> Deserialize<'de> for LoadMotor

Source§

fn deserialize<__D>(__deserializer: __D) -> Result<Self, __D::Error>
where __D: Deserializer<'de>,

Deserialize this value from the given Serde deserializer. Read more
Source§

impl Serialize for LoadMotor

Source§

fn serialize<__S>(&self, __serializer: __S) -> Result<__S::Ok, __S::Error>
where __S: Serializer,

Serialize this value into the given Serde serializer. Read more

Auto Trait Implementations§

Blanket Implementations§

Source§

impl<T> Any for T
where T: 'static + ?Sized,

Source§

fn type_id(&self) -> TypeId

Gets the TypeId of self. Read more
Source§

impl<T> Borrow<T> for T
where T: ?Sized,

Source§

fn borrow(&self) -> &T

Immutably borrows from an owned value. Read more
Source§

impl<T> BorrowMut<T> for T
where T: ?Sized,

Source§

fn borrow_mut(&mut self) -> &mut T

Mutably borrows from an owned value. Read more
Source§

impl<T> CloneToUninit for T
where T: Clone,

Source§

unsafe fn clone_to_uninit(&self, dest: *mut u8)

🔬This is a nightly-only experimental API. (clone_to_uninit)
Performs copy-assignment from self to dest. Read more
Source§

impl<T> DeserializeOwned for T
where T: for<'de> Deserialize<'de>,

Source§

impl<T> From<T> for T

Source§

fn from(t: T) -> T

Returns the argument unchanged.

Source§

impl<T, U> Into<U> for T
where U: From<T>,

Source§

fn into(self) -> U

Calls U::from(self).

That is, this conversion is whatever the implementation of From<T> for U chooses to do.

Source§

impl<T> ToOwned for T
where T: Clone,

Source§

type Owned = T

The resulting type after obtaining ownership.
Source§

fn to_owned(&self) -> T

Creates owned data from borrowed data, usually by cloning. Read more
Source§

fn clone_into(&self, target: &mut T)

Uses borrowed data to replace owned data, usually by cloning. Read more
Source§

impl<T, U> TryFrom<U> for T
where U: Into<T>,

Source§

type Error = !

The type returned in the event of a conversion error.
Source§

fn try_from(value: U) -> Result<T, !>

Performs the conversion.
Source§

impl<T, U> TryInto<U> for T
where U: TryFrom<T>,

Source§

type Error = <U as TryFrom<T>>::Error

The type returned in the event of a conversion error.
Source§

fn try_into(self) -> Result<U, <U as TryFrom<T>>::Error>

Performs the conversion.