pub enum UnitSymbol {
Show 141 variants none, m, kg, s, A, K, mol, cd, deg, rad, sr, Gy, Bq, degC, Sv, F, C, S, H, V, ohm, J, N, Hz, lx, lm, Wb, T, W, Pa, m2, m3, mPers, mPers2, m3Pers, mPerm3, kgm, kgPerm3, m2Pers, WPermK, JPerK, ppm, rotPers, radPers, WPerm2, JPerm2, SPerm, KPers, PaPers, JPerkgK, VA, VAr, cosPhi, Vs, V2, As, A2, A2s, VAh, Wh, VArh, VPerHz, HzPers, character, charPers, kgm2, dB, WPers, lPers, dBm, h, min, Q, Qh, ohmm, APerm, V2h, A2h, Ah, count, ft3, m3Perh, gal, Btu, l, lPerh, lPerl, gPerg, molPerm3, molPermol, molPerkg, sPers, HzPerHz, VPerV, APerA, VPerVA, rev, kat, JPerkg, m3Uncompensated, m3Compensated, WPerW, therm, onePerm, m3Perkg, Pas, Nm, NPerm, radPers2, JPerm3, VPerm, CPerm3, CPerm2, FPerm, HPerm, JPermol, JPermolK, CPerkg, GyPers, WPersr, WPerm2sr, katPerm3, d, anglemin, anglesec, ha, tonne, bar, mmHg, M, kn, Mx, G, Oe, Vh, WPerA, onePerHz, VPerVAr, ohmPerm, kgPerJ, JPers,
}
Expand description

The derived units defined for usage in the CIM. In some cases, the derived unit is equal to an SI unit. Whenever possible, the standard derived symbol is used instead of the formula for the derived unit. For example, the unit symbol Farad is defined as ‘F’ instead of ‘CPerV’. In cases where a standard symbol does not exist for a derived unit, the formula for the unit is used as the unit symbol. For example, density does not have a standard symbol and so it is represented as ‘kgPerm3’. With the exception of the ‘kg’, which is an SI unit, the unit symbols do not contain multipliers and therefore represent the base derived unit to which a multiplier can be applied as a whole. Every unit symbol is treated as an unparseable text as if it were a single-letter symbol. The meaning of each unit symbol is defined by the accompanying descriptive text and not by the text contents of the unit symbol. To allow the widest possible range of serializations without requiring special character handling, several substitutions are made which deviate from the format described in IEC 80000-1. The division symbol ‘/’ is replaced by the letters ‘Per’. Exponents are written in plain text after the unit as ‘m3’ instead of being formatted as ‘m’ with a superscript of 3 or introducing a symbol as in ‘m^3’. The degree symbol ‘°’ is replaced with the letters ‘deg’. Any clarification of the meaning for a substitution is included in the description for the unit symbol. Non-SI units are included in list of unit symbols to allow sources of data to be correctly labelled with their non-SI units (for example, a GPS sensor that is reporting numbers that represent feet instead of meters). This allows software to use the unit symbol information correctly convert and scale the raw data of those sources into SI-based units. The integer values are used for harmonization with IEC 61850.

Variants§

§

none

Dimension less quantity, e.g. count, per unit, etc.

§

m

Length in metres.

§

kg

Mass in kilograms. Note: multiplier “k” is included in this unit symbol for compatibility with IEC 61850-7-3.

§

s

Time in seconds.

§

A

Current in amperes.

§

K

Temperature in kelvins.

§

mol

Amount of substance in moles.

§

cd

Luminous intensity in candelas.

§

deg

Plane angle in degrees.

§

rad

Plane angle in radians (m/m).

§

sr

Solid angle in steradians (m2/m2).

§

Gy

Absorbed dose in grays (J/kg).

§

Bq

Radioactivity in becquerels (1/s).

§

degC

Relative temperature in degrees Celsius. In the SI unit system the symbol is °C. Electric charge is measured in coulomb that has the unit symbol C. To distinguish degree Celsius from coulomb the symbol used in the UML is degC. The reason for not using °C is that the special character ° is difficult to manage in software.

§

Sv

Dose equivalent in sieverts (J/kg).

§

F

Electric capacitance in farads (C/V).

§

C

Electric charge in coulombs (A·s).

§

S

Conductance in siemens.

§

H

Electric inductance in henrys (Wb/A).

§

V

Electric potential in volts (W/A).

§

ohm

Electric resistance in ohms (V/A).

§

J

Energy in joules (N·m = C·V = W·s).

§

N

Force in newtons (kg·m/s²).

§

Hz

Frequency in hertz (1/s).

§

lx

Illuminance in lux (lm/m²).

§

lm

Luminous flux in lumens (cd·sr).

§

Wb

Magnetic flux in webers (V·s).

§

T

Magnetic flux density in teslas (Wb/m2).

§

W

Real power in watts (J/s). Electrical power may have real and reactive components. The real portion of electrical power (I²R or VIcos(phi)), is expressed in Watts. See also apparent power and reactive power.

§

Pa

Pressure in pascals (N/m²). Note: the absolute or relative measurement of pressure is implied with this entry. See below for more explicit forms.

§

m2

Area in square metres (m²).

§

m3

Volume in cubic metres (m³).

§

mPers

Velocity in metres per second (m/s).

§

mPers2

Acceleration in metres per second squared (m/s²).

§

m3Pers

Volumetric flow rate in cubic metres per second (m³/s).

§

mPerm3

Fuel efficiency in metres per cubic metres (m/m³).

§

kgm

Moment of mass in kilogram metres (kg·m) (first moment of mass). Note: multiplier “k” is included in this unit symbol for compatibility with IEC 61850-7-3.

§

kgPerm3

Density in kilogram/cubic metres (kg/m³). Note: multiplier “k” is included in this unit symbol for compatibility with IEC 61850-7-3.

§

m2Pers

Viscosity in square metres / second (m²/s).

§

WPermK

Thermal conductivity in watt/metres kelvin.

§

JPerK

Heat capacity in joules/kelvin.

§

ppm

Concentration in parts per million.

§

rotPers

Rotations per second (1/s). See also Hz (1/s).

§

radPers

Angular velocity in radians per second (rad/s).

§

WPerm2

Heat flux density, irradiance, watts per square metre.

§

JPerm2

Insulation energy density, joules per square metre or watt second per square metre.

§

SPerm

Conductance per length (F/m).

§

KPers

Temperature change rate in kelvins per second.

§

PaPers

Pressure change rate in pascals per second.

§

JPerkgK

Specific heat capacity, specific entropy, joules per kilogram Kelvin.

§

VA

Apparent power in volt amperes. See also real power and reactive power.

§

VAr

Reactive power in volt amperes reactive. The “reactive” or “imaginary” component of electrical power (VIsin(phi)). (See also real power and apparent power). Note: Different meter designs use different methods to arrive at their results. Some meters may compute reactive power as an arithmetic value, while others compute the value vectorially. The data consumer should determine the method in use and the suitability of the measurement for the intended purpose.

§

cosPhi

Power factor, dimensionless. Note 1: This definition of power factor only holds for balanced systems. See the alternative definition under code 153. Note 2 : Beware of differing sign conventions in use between the IEC and EEI. It is assumed that the data consumer understands the type of meter in use and the sign convention in use by the utility.

§

Vs

Volt seconds (Ws/A).

§

V2

Volt squared (W²/A²).

§

As

Ampere seconds (A·s).

§

A2

Amperes squared (A²).

§

A2s

Ampere squared time in square amperes (A²s).

§

VAh

Apparent energy in volt ampere hours.

§

Wh

Real energy in watt hours.

§

VArh

Reactive energy in volt ampere reactive hours.

§

VPerHz

Magnetic flux in volt per hertz.

§

HzPers

Rate of change of frequency in hertz per second.

§

character

Number of characters.

§

charPers

Data rate (baud) in characters per second.

§

kgm2

Moment of mass in kilogram square metres (kg·m²) (Second moment of mass, commonly called the moment of inertia). Note: multiplier “k” is included in this unit symbol for compatibility with IEC 61850-7-3.

§

dB

Sound pressure level in decibels. Note: multiplier “d” is included in this unit symbol for compatibility with IEC 61850-7-3.

§

WPers

Ramp rate in watts per second.

§

lPers

Volumetric flow rate in litres per second.

§

dBm

Power level (logarithmic ratio of signal strength , Bel-mW), normalized to 1mW. Note: multiplier “d” is included in this unit symbol for compatibility with IEC 61850-7-3.

§

h

Time in hours, hour = 60 min = 3600 s.

§

min

Time in minutes, minute = 60 s.

§

Q

Quantity power, Q.

§

Qh

Quantity energy, Qh.

§

ohmm

Resistivity, ohm metres, (rho).

§

APerm

A/m, magnetic field strength, amperes per metre.

§

V2h

Volt-squared hour, volt-squared-hours.

§

A2h

Ampere-squared hour, ampere-squared hour.

§

Ah

Ampere-hours, ampere-hours.

§

count

Amount of substance, Counter value.

§

ft3

Volume, cubic feet.

§

m3Perh

Volumetric flow rate, cubic metres per hour.

§

gal

Volume in gallons, US gallon (1 gal = 231 in3 = 128 fl ounce).

§

Btu

Energy, British Thermal Units.

§

l

Volume in litres, litre = dm3 = m3/1000.

§

lPerh

Volumetric flow rate, litres per hour.

§

lPerl

Concentration, The ratio of the volume of a solute divided by the volume of the solution. Note: Users may need use a prefix such a ‘µ’ to express a quantity such as ‘µL/L’.

§

gPerg

Concentration, The ratio of the mass of a solute divided by the mass of the solution. Note: Users may need use a prefix such a ‘µ’ to express a quantity such as ‘µg/g’.

§

molPerm3

Concentration, The amount of substance concentration, (c), the amount of solvent in moles divided by the volume of solution in m³.

§

molPermol

Concentration, Molar fraction, the ratio of the molar amount of a solute divided by the molar amount of the solution.

§

molPerkg

Concentration, Molality, the amount of solute in moles and the amount of solvent in kilograms.

§

sPers

Time, Ratio of time. Note: Users may need to supply a prefix such as ‘µ’ to show rates such as ‘µs/s’.

§

HzPerHz

Frequency, rate of frequency change. Note: Users may need to supply a prefix such as ‘m’ to show rates such as ‘mHz/Hz’.

§

VPerV

Voltage, ratio of voltages. Note: Users may need to supply a prefix such as ‘m’ to show rates such as ‘mV/V’.

§

APerA

Current, ratio of amperages. Note: Users may need to supply a prefix such as ‘m’ to show rates such as ‘mA/A’.

§

VPerVA

Power factor, PF, the ratio of the active power to the apparent power. Note: The sign convention used for power factor will differ between IEC meters and EEI (ANSI) meters. It is assumed that the data consumers understand the type of meter being used and agree on the sign convention in use at any given utility.

§

rev

Amount of rotation, revolutions.

§

kat

Catalytic activity, katal = mol / s.

§

JPerkg

Specific energy, Joules / kg.

§

m3Uncompensated

Volume, cubic metres, with the value uncompensated for weather effects.

§

m3Compensated

Volume, cubic metres, with the value compensated for weather effects.

§

WPerW

Signal Strength, ratio of power. Note: Users may need to supply a prefix such as ‘m’ to show rates such as ‘mW/W’.

§

therm

Energy, therms.

§

onePerm

Wavenumber, reciprocal metres, (1/m).

§

m3Perkg

Specific volume, cubic metres per kilogram, v.

§

Pas

Dynamic viscosity, pascal seconds.

§

Nm

Moment of force, newton metres.

§

NPerm

Surface tension, newton per metre.

§

radPers2

Angular acceleration, radians per second squared.

§

JPerm3

Energy density, joules per cubic metre.

§

VPerm

Electric field strength, volts per metre.

§

CPerm3

Electric charge density, coulombs per cubic metre.

§

CPerm2

Surface charge density, coulombs per square metre.

§

FPerm

Permittivity, farads per metre.

§

HPerm

Permeability, henrys per metre.

§

JPermol

Molar energy, joules per mole.

§

JPermolK

Molar entropy, molar heat capacity, joules per mole kelvin.

§

CPerkg

Exposure (x rays), coulombs per kilogram.

§

GyPers

Absorbed dose rate, grays per second.

§

WPersr

Radiant intensity, watts per steradian.

§

WPerm2sr

Radiance, watts per square metre steradian.

§

katPerm3

Catalytic activity concentration, katals per cubic metre.

§

d

Time in days, day = 24 h = 86400 s.

§

anglemin

Plane angle, minutes.

§

anglesec

Plane angle, seconds.

§

ha

Area, hectares.

§

tonne

Mass in tons, “tonne” or “metric ton” (1000 kg = 1 Mg).

§

bar

Pressure in bars, (1 bar = 100 kPa).

§

mmHg

Pressure, millimetres of mercury (1 mmHg is approximately 133.3 Pa).

§

M

Length, nautical miles (1 M = 1852 m).

§

kn

Speed, knots (1 kn = 1852/3600) m/s.

§

Mx

Magnetic flux, maxwells (1 Mx = 10-8 Wb).

§

G

Magnetic flux density, gausses (1 G = 10-4 T).

§

Oe

Magnetic field in oersteds, (1 Oe = (103/4p) A/m).

§

Vh

Volt-hour, Volt hours.

§

WPerA

Active power per current flow, watts per Ampere.

§

onePerHz

Reciprocal of frequency (1/Hz).

§

VPerVAr

Power factor, PF, the ratio of the active power to the apparent power. Note: The sign convention used for power factor will differ between IEC meters and EEI (ANSI) meters. It is assumed that the data consumers understand the type of meter being used and agree on the sign convention in use at any given utility.

§

ohmPerm

Electric resistance per length in ohms per metre ((V/A)/m).

§

kgPerJ

Weight per energy in kilograms per joule (kg/J). Note: multiplier “k” is included in this unit symbol for compatibility with IEC 61850-7-3.

§

JPers

Energy rate in joules per second (J/s).

Implementations§

Source§

impl UnitSymbol

Source

pub fn uri(&self) -> &'static str

Trait Implementations§

Source§

impl Clone for UnitSymbol

Source§

fn clone(&self) -> UnitSymbol

Returns a duplicate of the value. Read more
1.0.0 (const: unstable) · Source§

fn clone_from(&mut self, source: &Self)

Performs copy-assignment from source. Read more
Source§

impl Debug for UnitSymbol

Source§

fn fmt(&self, f: &mut Formatter<'_>) -> Result

Formats the value using the given formatter. Read more
Source§

impl<'de> Deserialize<'de> for UnitSymbol

Source§

fn deserialize<__D>(__deserializer: __D) -> Result<Self, __D::Error>
where __D: Deserializer<'de>,

Deserialize this value from the given Serde deserializer. Read more
Source§

impl PartialEq for UnitSymbol

Source§

fn eq(&self, other: &UnitSymbol) -> bool

Equality operator ==. Read more
1.0.0 (const: unstable) · Source§

fn ne(&self, other: &Rhs) -> bool

Inequality operator !=. Read more
Source§

impl Serialize for UnitSymbol

Source§

fn serialize<__S>(&self, __serializer: __S) -> Result<__S::Ok, __S::Error>
where __S: Serializer,

Serialize this value into the given Serde serializer. Read more
Source§

impl StructuralPartialEq for UnitSymbol

Auto Trait Implementations§

Blanket Implementations§

Source§

impl<T> Any for T
where T: 'static + ?Sized,

Source§

fn type_id(&self) -> TypeId

Gets the TypeId of self. Read more
Source§

impl<T> Borrow<T> for T
where T: ?Sized,

Source§

fn borrow(&self) -> &T

Immutably borrows from an owned value. Read more
Source§

impl<T> BorrowMut<T> for T
where T: ?Sized,

Source§

fn borrow_mut(&mut self) -> &mut T

Mutably borrows from an owned value. Read more
Source§

impl<T> CloneToUninit for T
where T: Clone,

Source§

unsafe fn clone_to_uninit(&self, dest: *mut u8)

🔬This is a nightly-only experimental API. (clone_to_uninit)
Performs copy-assignment from self to dest. Read more
Source§

impl<T> DeserializeOwned for T
where T: for<'de> Deserialize<'de>,

Source§

impl<T> From<T> for T

Source§

fn from(t: T) -> T

Returns the argument unchanged.

Source§

impl<T, U> Into<U> for T
where U: From<T>,

Source§

fn into(self) -> U

Calls U::from(self).

That is, this conversion is whatever the implementation of From<T> for U chooses to do.

Source§

impl<T> ToOwned for T
where T: Clone,

Source§

type Owned = T

The resulting type after obtaining ownership.
Source§

fn to_owned(&self) -> T

Creates owned data from borrowed data, usually by cloning. Read more
Source§

fn clone_into(&self, target: &mut T)

Uses borrowed data to replace owned data, usually by cloning. Read more
Source§

impl<T, U> TryFrom<U> for T
where U: Into<T>,

Source§

type Error = !

The type returned in the event of a conversion error.
Source§

fn try_from(value: U) -> Result<T, !>

Performs the conversion.
Source§

impl<T, U> TryInto<U> for T
where U: TryFrom<T>,

Source§

type Error = <U as TryFrom<T>>::Error

The type returned in the event of a conversion error.
Source§

fn try_into(self) -> Result<U, <U as TryFrom<T>>::Error>

Performs the conversion.