[−][src]Struct cc13x2_cc26x2_hal::crypto::keywritearea::R
Value read from the register
Methods
impl R
[src]
pub fn bits(&self) -> u32
[src]
Value of the register as raw bits
pub fn reserved8(&self) -> RESERVED8R
[src]
Bits 8:31 - 31:8] Software should not rely on the value of a reserved. Writing any other value than the reset value may result in undefined behavior.
pub fn ram_area7(&self) -> RAM_AREA7R
[src]
Bit 7 - 7:7] Each RAM_AREAx represents an area of 128 bits. Select the key store RAM area(s) where the key(s) needs to be written 0: RAM_AREA7 is not selected to be written. 1: RAM_AREA7 is selected to be written. Writing to multiple RAM locations is possible only when the selected RAM areas are sequential. Keys that require more than one RAM locations (key size is 192 or 256 bits), must start at one of the following areas: RAM_AREA0, RAM_AREA2, RAM_AREA4, or RAM_AREA6.
pub fn ram_area6(&self) -> RAM_AREA6R
[src]
Bit 6 - 6:6] Each RAM_AREAx represents an area of 128 bits. Select the key store RAM area(s) where the key(s) needs to be written 0: RAM_AREA6 is not selected to be written. 1: RAM_AREA6 is selected to be written. Writing to multiple RAM locations is possible only when the selected RAM areas are sequential. Keys that require more than one RAM locations (key size is 192 or 256 bits), must start at one of the following areas: RAM_AREA0, RAM_AREA2, RAM_AREA4, or RAM_AREA6.
pub fn ram_area5(&self) -> RAM_AREA5R
[src]
Bit 5 - 5:5] Each RAM_AREAx represents an area of 128 bits. Select the key store RAM area(s) where the key(s) needs to be written 0: RAM_AREA5 is not selected to be written. 1: RAM_AREA5 is selected to be written. Writing to multiple RAM locations is possible only when the selected RAM areas are sequential. Keys that require more than one RAM locations (key size is 192 or 256 bits), must start at one of the following areas: RAM_AREA0, RAM_AREA2, RAM_AREA4, or RAM_AREA6.
pub fn ram_area4(&self) -> RAM_AREA4R
[src]
Bit 4 - 4:4] Each RAM_AREAx represents an area of 128 bits. Select the key store RAM area(s) where the key(s) needs to be written 0: RAM_AREA4 is not selected to be written. 1: RAM_AREA4 is selected to be written. Writing to multiple RAM locations is possible only when the selected RAM areas are sequential. Keys that require more than one RAM locations (key size is 192 or 256 bits), must start at one of the following areas: RAM_AREA0, RAM_AREA2, RAM_AREA4, or RAM_AREA6.
pub fn ram_area3(&self) -> RAM_AREA3R
[src]
Bit 3 - 3:3] Each RAM_AREAx represents an area of 128 bits. Select the key store RAM area(s) where the key(s) needs to be written 0: RAM_AREA3 is not selected to be written. 1: RAM_AREA3 is selected to be written. Writing to multiple RAM locations is possible only when the selected RAM areas are sequential. Keys that require more than one RAM locations (key size is 192 or 256 bits), must start at one of the following areas: RAM_AREA0, RAM_AREA2, RAM_AREA4, or RAM_AREA6.
pub fn ram_area2(&self) -> RAM_AREA2R
[src]
Bit 2 - 2:2] Each RAM_AREAx represents an area of 128 bits. Select the key store RAM area(s) where the key(s) needs to be written 0: RAM_AREA2 is not selected to be written. 1: RAM_AREA2 is selected to be written. Writing to multiple RAM locations is possible only when the selected RAM areas are sequential. Keys that require more than one RAM locations (key size is 192 or 256 bits), must start at one of the following areas: RAM_AREA0, RAM_AREA2, RAM_AREA4, or RAM_AREA6.
pub fn ram_area1(&self) -> RAM_AREA1R
[src]
Bit 1 - 1:1] Each RAM_AREAx represents an area of 128 bits. Select the key store RAM area(s) where the key(s) needs to be written 0: RAM_AREA1 is not selected to be written. 1: RAM_AREA1 is selected to be written. Writing to multiple RAM locations is possible only when the selected RAM areas are sequential. Keys that require more than one RAM locations (key size is 192 or 256 bits), must start at one of the following areas: RAM_AREA0, RAM_AREA2, RAM_AREA4, or RAM_AREA6.
pub fn ram_area0(&self) -> RAM_AREA0R
[src]
Bit 0 - 0:0] Each RAM_AREAx represents an area of 128 bits. Select the key store RAM area(s) where the key(s) needs to be written 0: RAM_AREA0 is not selected to be written. 1: RAM_AREA0 is selected to be written. Writing to multiple RAM locations is possible only when the selected RAM areas are sequential. Keys that require more than one RAM locations (key size is 192 or 256 bits), must start at one of the following areas: RAM_AREA0, RAM_AREA2, RAM_AREA4, or RAM_AREA6.
Auto Trait Implementations
Blanket Implementations
impl<T, U> TryFrom for T where
U: Into<T>,
[src]
U: Into<T>,
type Error = Infallible
The type returned in the event of a conversion error.
fn try_from(value: U) -> Result<T, <T as TryFrom<U>>::Error>
[src]
impl<T> From for T
[src]
impl<T, U> TryInto for T where
U: TryFrom<T>,
[src]
U: TryFrom<T>,
type Error = <U as TryFrom<T>>::Error
The type returned in the event of a conversion error.
fn try_into(self) -> Result<U, <U as TryFrom<T>>::Error>
[src]
impl<T, U> Into for T where
U: From<T>,
[src]
U: From<T>,
impl<T> Borrow for T where
T: ?Sized,
[src]
T: ?Sized,
impl<T> BorrowMut for T where
T: ?Sized,
[src]
T: ?Sized,
fn borrow_mut(&mut self) -> &mut T
[src]
impl<T> Any for T where
T: 'static + ?Sized,
[src]
T: 'static + ?Sized,
impl<T> Same for T
type Output = T
Should always be Self