1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266
use serde::Deserialize;
use serde::de::Unexpected;
use serde::de;
use serde::Deserializer;
use zigbee2mqtt_types_base_types::LastSeen;
/// perenio:PECLS01 [zigbee2mqtt link](https://www.zigbee2mqtt.io/devices/PECLS01.html)
///
///
#[cfg_attr(feature = "debug", derive(Debug))]
#[cfg_attr(feature = "clone", derive(Clone))]
#[derive(Deserialize)]
pub struct ZigbeePecls01 {
///Remaining battery in %, can take up to 24 hours before reported.
pub battery: f64,
///Zigbee herdsman description: "Indicates if the battery of this device is almost empty"
///Boolean values can be an unintuitive way round: value_on = true and value_off = false, consider double checking Zigbee2MQTT to understand what they mean
pub battery_low: bool,
///Link quality (signal strength)
pub linkquality: f64,
///Zigbee herdsman description: "Indicates whether the device is tampered"
///Boolean values can be an unintuitive way round: value_on = true and value_off = false, consider double checking Zigbee2MQTT to understand what they mean
pub tamper: bool,
///Zigbee herdsman description: "Indicates whether the device detected a water leak"
///Boolean values can be an unintuitive way round: value_on = true and value_off = false, consider double checking Zigbee2MQTT to understand what they mean
pub water_leak: bool,
/// Optional last_seen type, set as a global zigbee2mqtt setting
pub last_seen: Option<LastSeen>,
/// Optional elapsed type
pub elapsed: Option<u64>,
}/// perenio:PECMS01 [zigbee2mqtt link](https://www.zigbee2mqtt.io/devices/PECMS01.html)
///
///
#[cfg_attr(feature = "debug", derive(Debug))]
#[cfg_attr(feature = "clone", derive(Clone))]
#[derive(Deserialize)]
pub struct ZigbeePecms01 {
///Remaining battery in %, can take up to 24 hours before reported.
pub battery: f64,
///Zigbee herdsman description: "Indicates if the battery of this device is almost empty"
///Boolean values can be an unintuitive way round: value_on = true and value_off = false, consider double checking Zigbee2MQTT to understand what they mean
pub battery_low: bool,
///Link quality (signal strength)
pub linkquality: f64,
///Zigbee herdsman description: "Indicates whether the device detected occupancy"
///Boolean values can be an unintuitive way round: value_on = true and value_off = false, consider double checking Zigbee2MQTT to understand what they mean
pub occupancy: bool,
///Zigbee herdsman description: "Indicates whether the device is tampered"
///Boolean values can be an unintuitive way round: value_on = true and value_off = false, consider double checking Zigbee2MQTT to understand what they mean
pub tamper: bool,
/// Optional last_seen type, set as a global zigbee2mqtt setting
pub last_seen: Option<LastSeen>,
/// Optional elapsed type
pub elapsed: Option<u64>,
}/// perenio:PECWS01 [zigbee2mqtt link](https://www.zigbee2mqtt.io/devices/PECWS01.html)
///
///
#[cfg_attr(feature = "debug", derive(Debug))]
#[cfg_attr(feature = "clone", derive(Clone))]
#[derive(Deserialize)]
pub struct ZigbeePecws01 {
///Remaining battery in %, can take up to 24 hours before reported.
pub battery: f64,
///Zigbee herdsman description: "Indicates if the contact is closed (= true) or open (= false)"
///Boolean values can be an unintuitive way round: value_on = false and value_off = true, consider double checking Zigbee2MQTT to understand what they mean
pub contact: bool,
///Link quality (signal strength)
pub linkquality: f64,
///Voltage of the battery in millivolts
pub voltage: f64,
/// Optional last_seen type, set as a global zigbee2mqtt setting
pub last_seen: Option<LastSeen>,
/// Optional elapsed type
pub elapsed: Option<u64>,
}/// perenio:PEHPL0X [zigbee2mqtt link](https://www.zigbee2mqtt.io/devices/PEHPL0X.html)
///
///
#[cfg_attr(feature = "debug", derive(Debug))]
#[cfg_attr(feature = "clone", derive(Clone))]
#[derive(Deserialize)]
pub struct ZigbeePehpl0x {
///Active power
pub active_power: f64,
///Zigbee herdsman description: "Indicates if the alarm is triggered when the consumption energy limit is reached, allows to reset alarms"
///Boolean values can be an unintuitive way round: value_on = true and value_off = false, consider double checking Zigbee2MQTT to understand what they mean
pub alarm_consumed_energy: bool,
///Zigbee herdsman description: "Indicates if the alarm is triggered on the active power rise above the limit, allows to reset alarms"
///Boolean values can be an unintuitive way round: value_on = true and value_off = false, consider double checking Zigbee2MQTT to understand what they mean
pub alarm_power_max: bool,
///Zigbee herdsman description: "Indicates if the alarm is triggered on the voltage rise above the limit, allows to reset alarms"
///Boolean values can be an unintuitive way round: value_on = true and value_off = false, consider double checking Zigbee2MQTT to understand what they mean
pub alarm_voltage_max: bool,
///Zigbee herdsman description: "Indicates if the alarm is triggered on the voltage drop below the limit, allows to reset alarms"
///Boolean values can be an unintuitive way round: value_on = true and value_off = false, consider double checking Zigbee2MQTT to understand what they mean
pub alarm_voltage_min: bool,
///Consumed energy
pub consumed_energy: f64,
///Limit of electric energy consumption in kW*h. 0 value represents no limit
pub consumed_energy_limit: f64,
pub default_on_off_state: ZigbeePehpl0xDefaultonoffstate,
///Link quality (signal strength)
pub linkquality: f64,
///Maximum allowable power limit for alarms.
pub power_max: f64,
///RMS voltage
pub rms_voltage: f64,
///RSSI seen by the device
pub rssi: f64,
///Zigbee herdsman description: "On/off state of the switch"
///The string values get converted into boolean with: ON = true and OFF = false
#[serde(deserialize_with = "zigbeepehpl0x_state_deserializer")]
pub state: bool,
///Maximum allowable voltage limit for alarms.
pub voltage_max: f64,
///Minimum allowable voltage limit for alarms.
pub voltage_min: f64,
/// Optional last_seen type, set as a global zigbee2mqtt setting
pub last_seen: Option<LastSeen>,
/// Optional elapsed type
pub elapsed: Option<u64>,
}
/// Deserialize bool from String with custom value mapping
fn zigbeepehpl0x_state_deserializer<'de, D>(deserializer: D) -> Result<bool, D::Error>
where
D: Deserializer<'de>,
{
match String::deserialize(deserializer)?.as_ref() {
"ON" => Ok(true),
"OFF" => Ok(false),
other => Err(de::Error::invalid_value(
Unexpected::Str(other),
&"Value expected was either ON or OFF",
)),
}
}
/// perenio:PEHWE20 [zigbee2mqtt link](https://www.zigbee2mqtt.io/devices/PEHWE20.html)
///
///
#[cfg_attr(feature = "debug", derive(Debug))]
#[cfg_attr(feature = "clone", derive(Clone))]
#[derive(Deserialize)]
pub struct ZigbeePehwe20 {
///LQI seen by the device
pub last_message_lqi: f64,
///RSSI seen by the device
pub last_message_rssi: f64,
///Link quality (signal strength)
pub linkquality: f64,
///Controls the behavior when the device is powered on after power loss
pub power_on_behavior_l1: ZigbeePehwe20Poweronbehaviorl1,
///Controls the behavior when the device is powered on after power loss
pub power_on_behavior_l2: ZigbeePehwe20Poweronbehaviorl2,
///Zigbee herdsman description: "On/off state of the switch"
///The string values get converted into boolean with: ON = true and OFF = false
#[serde(deserialize_with = "zigbeepehwe20_state_l1_deserializer")]
pub state_l1: bool,
///Zigbee herdsman description: "On/off state of the switch"
///The string values get converted into boolean with: ON = true and OFF = false
#[serde(deserialize_with = "zigbeepehwe20_state_l2_deserializer")]
pub state_l2: bool,
pub switch_type_l1: ZigbeePehwe20Switchtypel1,
pub switch_type_l2: ZigbeePehwe20Switchtypel2,
/// Optional last_seen type, set as a global zigbee2mqtt setting
pub last_seen: Option<LastSeen>,
/// Optional elapsed type
pub elapsed: Option<u64>,
}
/// Deserialize bool from String with custom value mapping
fn zigbeepehwe20_state_l1_deserializer<'de, D>(deserializer: D) -> Result<bool, D::Error>
where
D: Deserializer<'de>,
{
match String::deserialize(deserializer)?.as_ref() {
"ON" => Ok(true),
"OFF" => Ok(false),
other => Err(de::Error::invalid_value(
Unexpected::Str(other),
&"Value expected was either ON or OFF",
)),
}
}
/// Deserialize bool from String with custom value mapping
fn zigbeepehwe20_state_l2_deserializer<'de, D>(deserializer: D) -> Result<bool, D::Error>
where
D: Deserializer<'de>,
{
match String::deserialize(deserializer)?.as_ref() {
"ON" => Ok(true),
"OFF" => Ok(false),
other => Err(de::Error::invalid_value(
Unexpected::Str(other),
&"Value expected was either ON or OFF",
)),
}
}
#[cfg_attr(feature = "debug", derive(Debug))]
#[cfg_attr(feature = "clone", derive(Clone))]
#[derive(Deserialize, PartialEq)]
pub enum ZigbeePehpl0xDefaultonoffstate {
#[serde(rename = "off")]
Off,
#[serde(rename = "on")]
On,
#[serde(rename = "previous")]
Previous,
}
#[cfg_attr(feature = "debug", derive(Debug))]
#[cfg_attr(feature = "clone", derive(Clone))]
#[derive(Deserialize, PartialEq)]
pub enum ZigbeePehwe20Poweronbehaviorl1 {
#[serde(rename = "off")]
Off,
#[serde(rename = "on")]
On,
#[serde(rename = "previous")]
Previous,
}
#[cfg_attr(feature = "debug", derive(Debug))]
#[cfg_attr(feature = "clone", derive(Clone))]
#[derive(Deserialize, PartialEq)]
pub enum ZigbeePehwe20Poweronbehaviorl2 {
#[serde(rename = "off")]
Off,
#[serde(rename = "on")]
On,
#[serde(rename = "previous")]
Previous,
}
#[cfg_attr(feature = "debug", derive(Debug))]
#[cfg_attr(feature = "clone", derive(Clone))]
#[derive(Deserialize, PartialEq)]
pub enum ZigbeePehwe20Switchtypel1 {
#[serde(rename = "maintained_state")]
MaintainedState,
#[serde(rename = "maintained_toggle")]
MaintainedToggle,
#[serde(rename = "momentary_press")]
MomentaryPress,
#[serde(rename = "momentary_release")]
MomentaryRelease,
#[serde(rename = "momentary_state")]
MomentaryState,
}
#[cfg_attr(feature = "debug", derive(Debug))]
#[cfg_attr(feature = "clone", derive(Clone))]
#[derive(Deserialize, PartialEq)]
pub enum ZigbeePehwe20Switchtypel2 {
#[serde(rename = "maintained_state")]
MaintainedState,
#[serde(rename = "maintained_toggle")]
MaintainedToggle,
#[serde(rename = "momentary_press")]
MomentaryPress,
#[serde(rename = "momentary_release")]
MomentaryRelease,
#[serde(rename = "momentary_state")]
MomentaryState,
}
#[cfg(all(feature = "last_seen_epoch", feature = "last_seen_iso_8601"))]
compile_error!{"Feature last_seen epoch and iso_8601 are mutually exclusive and cannot be enabled together.
This was done because it is a global setting in zigbee2mqtt and therefor can't see a reason both would be enabled.
If you have a any reason to have both ways enabled please submit an issue to https://gitlab.com/seam345/zigbee2mqtt-types/-/issues"}