Enum xmc4200::hrpwm0_csg0::sc::SVSC_A
source · #[repr(u8)]pub enum SVSC_A {
VALUE1 = 0,
VALUE2 = 1,
VALUE3 = 2,
}
Expand description
Slope reference value mode
Value on reset: 0
Variants§
VALUE1 = 0
0: Only CSGyDSV1This register contains the actual value used for the DSV1 reference. value is used for the slope generation: if slope is incrementing, CSGyDSV1This register contains the actual value used for the DSV1 reference. is the bottom reference value from where the ramp starts; if decrementing, then CSGyDSV1This register contains the actual value used for the DSV1 reference. is the upper reference value from where the ramp starts.
VALUE2 = 1
1: The two reference values are being used: CSGyDSV1This register contains the actual value used for the DSV1 reference. is the low or high reference value from where the ramp starts (incrementing or decrementing respectively); CSGyDSV2This register contains the actual value used for the DSV2 reference. is used as a static value (this value is constantly fed to the DAC after a stop trigger as been detected).
VALUE3 = 2
2: The two reference values are used: CSGyDSV1This register contains the actual value used for the DSV1 reference. is the low or high reference value from where the slope starts (incrementing or decrementing respectively); CSGyDSV2This register contains the actual value used for the DSV2 reference. is used as an internal re start condition for the slope.