Measures power, DC voltage and DC current up to 720W/36V/20A

Methods

impl VoltageCurrentV2Bricklet
[src]

pub const DEVICE_IDENTIFIER: u16[src]

pub const DEVICE_DISPLAY_NAME: &'static str[src]

pub fn new(uid: &str, ip_connection: &IpConnection) -> VoltageCurrentV2Bricklet
[src]

Creates an object with the unique device ID uid. This object can then be used after the IP Connection ip_connection is connected.

pub fn get_response_expected(
    &mut self,
    fun: VoltageCurrentV2BrickletFunction
) -> Result<bool, GetResponseExpectedError>
[src]

Returns the response expected flag for the function specified by the function ID parameter. It is true if the function is expected to send a response, false otherwise.

For getter functions this is enabled by default and cannot be disabled, because those functions will always send a response. For callback configuration functions it is enabled by default too, but can be disabled by set_response_expected. For setter functions it is disabled by default and can be enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is send and errors are silently ignored, because they cannot be detected.

See set_response_expected for the list of function ID constants available for this function.

pub fn set_response_expected(
    &mut self,
    fun: VoltageCurrentV2BrickletFunction,
    response_expected: bool
) -> Result<(), SetResponseExpectedError>
[src]

Changes the response expected flag of the function specified by the function ID parameter. This flag can only be changed for setter (default value: false) and callback configuration functions (default value: true). For getter functions it is always enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is send and errors are silently ignored, because they cannot be detected.

pub fn set_response_expected_all(&mut self, response_expected: bool)
[src]

Changes the response expected flag for all setter and callback configuration functions of this device at once.

pub fn get_api_version(&self) -> [u8; 3]
[src]

Returns the version of the API definition (major, minor, revision) implemented by this API bindings. This is neither the release version of this API bindings nor does it tell you anything about the represented Brick or Bricklet.

pub fn get_current_callback_receiver(&self) -> ConvertingCallbackReceiver<i32>
[src]

This receiver is triggered periodically according to the configuration set by set_current_callback_configuration.

The parameter is the same as get_current.

pub fn get_voltage_callback_receiver(&self) -> ConvertingCallbackReceiver<i32>
[src]

This receiver is triggered periodically according to the configuration set by set_voltage_callback_configuration.

The parameter is the same as get_voltage.

pub fn get_power_callback_receiver(&self) -> ConvertingCallbackReceiver<i32>
[src]

This receiver is triggered periodically according to the configuration set by set_power_callback_configuration.

The parameter is the same as get_power.

pub fn get_current(&self) -> ConvertingReceiver<i32>
[src]

Returns the current. The value is in mA and between -20000mA and 20000mA.

If you want to get the value periodically, it is recommended to use the get_current_callback_receiver receiver. You can set the receiver configuration with set_current_callback_configuration.

pub fn set_current_callback_configuration(
    &self,
    period: u32,
    value_has_to_change: bool,
    option: char,
    min: i32,
    max: i32
) -> ConvertingReceiver<()>
[src]

The period in ms is the period with which the get_current_callback_receiver receiver is triggered periodically. A value of 0 turns the receiver off.

If the value has to change-parameter is set to true, the receiver is only triggered after the value has changed. If the value didn't change within the period, the receiver is triggered immediately on change.

If it is set to false, the receiver is continuously triggered with the period, independent of the value.

It is furthermore possible to constrain the receiver with thresholds.

The option-parameter together with min/max sets a threshold for the get_current_callback_receiver receiver.

The following options are possible:

Option Description
'x' Threshold is turned off
'o' Threshold is triggered when the value is outside the min and max values
'i' Threshold is triggered when the value is inside or equal to the min and max values
'<' Threshold is triggered when the value is smaller than the min value (max is ignored)
'>' Threshold is triggered when the value is greater than the min value (max is ignored)

If the option is set to 'x' (threshold turned off) the receiver is triggered with the fixed period.

The default value is (0, false, 'x', 0, 0).

Associated constants:

  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_OFF
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_OUTSIDE
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_INSIDE
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_SMALLER
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_GREATER

pub fn get_current_callback_configuration(
    &self
) -> ConvertingReceiver<CurrentCallbackConfiguration>
[src]

Returns the receiver configuration as set by set_current_callback_configuration.

Associated constants:

  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_OFF
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_OUTSIDE
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_INSIDE
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_SMALLER
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_GREATER

pub fn get_voltage(&self) -> ConvertingReceiver<i32>
[src]

Returns the voltage. The value is in mV and between 0mV and 36000mV.

If you want to get the value periodically, it is recommended to use the get_voltage_callback_receiver receiver. You can set the receiver configuration with set_voltage_callback_configuration.

pub fn set_voltage_callback_configuration(
    &self,
    period: u32,
    value_has_to_change: bool,
    option: char,
    min: i32,
    max: i32
) -> ConvertingReceiver<()>
[src]

The period in ms is the period with which the get_voltage_callback_receiver receiver is triggered periodically. A value of 0 turns the receiver off.

If the value has to change-parameter is set to true, the receiver is only triggered after the value has changed. If the value didn't change within the period, the receiver is triggered immediately on change.

If it is set to false, the receiver is continuously triggered with the period, independent of the value.

It is furthermore possible to constrain the receiver with thresholds.

The option-parameter together with min/max sets a threshold for the get_voltage_callback_receiver receiver.

The following options are possible:

Option Description
'x' Threshold is turned off
'o' Threshold is triggered when the value is outside the min and max values
'i' Threshold is triggered when the value is inside or equal to the min and max values
'<' Threshold is triggered when the value is smaller than the min value (max is ignored)
'>' Threshold is triggered when the value is greater than the min value (max is ignored)

If the option is set to 'x' (threshold turned off) the receiver is triggered with the fixed period.

The default value is (0, false, 'x', 0, 0).

Associated constants:

  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_OFF
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_OUTSIDE
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_INSIDE
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_SMALLER
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_GREATER

pub fn get_voltage_callback_configuration(
    &self
) -> ConvertingReceiver<VoltageCallbackConfiguration>
[src]

Returns the receiver configuration as set by set_voltage_callback_configuration.

Associated constants:

  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_OFF
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_OUTSIDE
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_INSIDE
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_SMALLER
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_GREATER

pub fn get_power(&self) -> ConvertingReceiver<i32>
[src]

Returns the power. The value is in mW and between 0mV and 720000mW.

If you want to get the value periodically, it is recommended to use the get_power_callback_receiver receiver. You can set the receiver configuration with set_power_callback_configuration.

pub fn set_power_callback_configuration(
    &self,
    period: u32,
    value_has_to_change: bool,
    option: char,
    min: i32,
    max: i32
) -> ConvertingReceiver<()>
[src]

The period in ms is the period with which the get_power_callback_receiver receiver is triggered periodically. A value of 0 turns the receiver off.

If the value has to change-parameter is set to true, the receiver is only triggered after the value has changed. If the value didn't change within the period, the receiver is triggered immediately on change.

If it is set to false, the receiver is continuously triggered with the period, independent of the value.

It is furthermore possible to constrain the receiver with thresholds.

The option-parameter together with min/max sets a threshold for the get_power_callback_receiver receiver.

The following options are possible:

Option Description
'x' Threshold is turned off
'o' Threshold is triggered when the value is outside the min and max values
'i' Threshold is triggered when the value is inside or equal to the min and max values
'<' Threshold is triggered when the value is smaller than the min value (max is ignored)
'>' Threshold is triggered when the value is greater than the min value (max is ignored)

If the option is set to 'x' (threshold turned off) the receiver is triggered with the fixed period.

The default value is (0, false, 'x', 0, 0).

Associated constants:

  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_OFF
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_OUTSIDE
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_INSIDE
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_SMALLER
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_GREATER

pub fn get_power_callback_configuration(
    &self
) -> ConvertingReceiver<PowerCallbackConfiguration>
[src]

Returns the receiver configuration as set by set_power_callback_configuration.

Associated constants:

  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_OFF
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_OUTSIDE
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_INSIDE
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_SMALLER
  • VOLTAGE_CURRENT_V2_BRICKLET_THRESHOLD_OPTION_GREATER

pub fn set_configuration(
    &self,
    averaging: u8,
    voltage_conversion_time: u8,
    current_conversion_time: u8
) -> ConvertingReceiver<()>
[src]

Sets the configuration of the Voltage/Current Bricklet 2.0. It is possible to configure number of averages as well as voltage and current conversion time.

Averaging:

Value Number of Averages
0 1
1 4
2 16
3 64
4 128
5 256
6 512
>=7 1024

Voltage/Current conversion:

Value Conversion time
0 140µs
1 204µs
2 332µs
3 588µs
4 1.1ms
5 2.116ms
6 4.156ms
>=7 8.244ms

The default values are 3, 4 and 4 (64, 1.1ms, 1.1ms) for averaging, voltage conversion and current conversion.

Associated constants:

  • VOLTAGE_CURRENT_V2_BRICKLET_AVERAGING_1
  • VOLTAGE_CURRENT_V2_BRICKLET_AVERAGING_4
  • VOLTAGE_CURRENT_V2_BRICKLET_AVERAGING_16
  • VOLTAGE_CURRENT_V2_BRICKLET_AVERAGING_64
  • VOLTAGE_CURRENT_V2_BRICKLET_AVERAGING_128
  • VOLTAGE_CURRENT_V2_BRICKLET_AVERAGING_256
  • VOLTAGE_CURRENT_V2_BRICKLET_AVERAGING_512
  • VOLTAGE_CURRENT_V2_BRICKLET_AVERAGING_1024

pub fn get_configuration(&self) -> ConvertingReceiver<Configuration>
[src]

Returns the configuration as set by set_configuration.

Associated constants:

  • VOLTAGE_CURRENT_V2_BRICKLET_AVERAGING_1
  • VOLTAGE_CURRENT_V2_BRICKLET_AVERAGING_4
  • VOLTAGE_CURRENT_V2_BRICKLET_AVERAGING_16
  • VOLTAGE_CURRENT_V2_BRICKLET_AVERAGING_64
  • VOLTAGE_CURRENT_V2_BRICKLET_AVERAGING_128
  • VOLTAGE_CURRENT_V2_BRICKLET_AVERAGING_256
  • VOLTAGE_CURRENT_V2_BRICKLET_AVERAGING_512
  • VOLTAGE_CURRENT_V2_BRICKLET_AVERAGING_1024

pub fn set_calibration(
    &self,
    voltage_multiplier: u16,
    voltage_divisor: u16,
    current_multiplier: u16,
    current_divisor: u16
) -> ConvertingReceiver<()>
[src]

Since the ADC and the shunt resistor used for the measurements are not perfect they need to be calibrated by a multiplier and a divisor if a very precise reading is needed.

For example, if you are expecting a current of 1000mA and you are measuring 1023mA, you can calibrate the Voltage/Current Bricklet by setting the current multiplier to 1000 and the divisor to 1023. The same applies for the voltage.

pub fn get_calibration(&self) -> ConvertingReceiver<Calibration>
[src]

Returns the calibration as set by set_calibration.

pub fn get_spitfp_error_count(&self) -> ConvertingReceiver<SpitfpErrorCount>
[src]

Returns the error count for the communication between Brick and Bricklet.

The errors are divided into

  • ACK checksum errors,
  • message checksum errors,
  • framing errors and
  • overflow errors.

The errors counts are for errors that occur on the Bricklet side. All Bricks have a similar function that returns the errors on the Brick side.

pub fn set_bootloader_mode(&self, mode: u8) -> ConvertingReceiver<u8>
[src]

Sets the bootloader mode and returns the status after the requested mode change was instigated.

You can change from bootloader mode to firmware mode and vice versa. A change from bootloader mode to firmware mode will only take place if the entry function, device identifier and CRC are present and correct.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

Associated constants:

  • VOLTAGE_CURRENT_V2_BRICKLET_BOOTLOADER_MODE_BOOTLOADER
  • VOLTAGE_CURRENT_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE
  • VOLTAGE_CURRENT_V2_BRICKLET_BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT
  • VOLTAGE_CURRENT_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT
  • VOLTAGE_CURRENT_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT
  • VOLTAGE_CURRENT_V2_BRICKLET_BOOTLOADER_STATUS_OK
  • VOLTAGE_CURRENT_V2_BRICKLET_BOOTLOADER_STATUS_INVALID_MODE
  • VOLTAGE_CURRENT_V2_BRICKLET_BOOTLOADER_STATUS_NO_CHANGE
  • VOLTAGE_CURRENT_V2_BRICKLET_BOOTLOADER_STATUS_ENTRY_FUNCTION_NOT_PRESENT
  • VOLTAGE_CURRENT_V2_BRICKLET_BOOTLOADER_STATUS_DEVICE_IDENTIFIER_INCORRECT
  • VOLTAGE_CURRENT_V2_BRICKLET_BOOTLOADER_STATUS_CRC_MISMATCH

pub fn get_bootloader_mode(&self) -> ConvertingReceiver<u8>
[src]

Returns the current bootloader mode, see set_bootloader_mode.

Associated constants:

  • VOLTAGE_CURRENT_V2_BRICKLET_BOOTLOADER_MODE_BOOTLOADER
  • VOLTAGE_CURRENT_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE
  • VOLTAGE_CURRENT_V2_BRICKLET_BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT
  • VOLTAGE_CURRENT_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT
  • VOLTAGE_CURRENT_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT

pub fn set_write_firmware_pointer(&self, pointer: u32) -> ConvertingReceiver<()>
[src]

Sets the firmware pointer for write_firmware. The pointer has to be increased by chunks of size 64. The data is written to flash every 4 chunks (which equals to one page of size 256).

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

pub fn write_firmware(&self, data: [u8; 64]) -> ConvertingReceiver<u8>
[src]

Writes 64 Bytes of firmware at the position as written by set_write_firmware_pointer before. The firmware is written to flash every 4 chunks.

You can only write firmware in bootloader mode.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

pub fn set_status_led_config(&self, config: u8) -> ConvertingReceiver<()>
[src]

Sets the status LED configuration. By default the LED shows communication traffic between Brick and Bricklet, it flickers once for every 10 received data packets.

You can also turn the LED permanently on/off or show a heartbeat.

If the Bricklet is in bootloader mode, the LED is will show heartbeat by default.

Associated constants:

  • VOLTAGE_CURRENT_V2_BRICKLET_STATUS_LED_CONFIG_OFF
  • VOLTAGE_CURRENT_V2_BRICKLET_STATUS_LED_CONFIG_ON
  • VOLTAGE_CURRENT_V2_BRICKLET_STATUS_LED_CONFIG_SHOW_HEARTBEAT
  • VOLTAGE_CURRENT_V2_BRICKLET_STATUS_LED_CONFIG_SHOW_STATUS

pub fn get_status_led_config(&self) -> ConvertingReceiver<u8>
[src]

Returns the configuration as set by set_status_led_config

Associated constants:

  • VOLTAGE_CURRENT_V2_BRICKLET_STATUS_LED_CONFIG_OFF
  • VOLTAGE_CURRENT_V2_BRICKLET_STATUS_LED_CONFIG_ON
  • VOLTAGE_CURRENT_V2_BRICKLET_STATUS_LED_CONFIG_SHOW_HEARTBEAT
  • VOLTAGE_CURRENT_V2_BRICKLET_STATUS_LED_CONFIG_SHOW_STATUS

pub fn get_chip_temperature(&self) -> ConvertingReceiver<i16>
[src]

Returns the temperature in °C as measured inside the microcontroller. The value returned is not the ambient temperature!

The temperature is only proportional to the real temperature and it has bad accuracy. Practically it is only useful as an indicator for temperature changes.

pub fn reset(&self) -> ConvertingReceiver<()>
[src]

Calling this function will reset the Bricklet. All configurations will be lost.

After a reset you have to create new device objects, calling functions on the existing ones will result in undefined behavior!

pub fn write_uid(&self, uid: u32) -> ConvertingReceiver<()>
[src]

Writes a new UID into flash. If you want to set a new UID you have to decode the Base58 encoded UID string into an integer first.

We recommend that you use Brick Viewer to change the UID.

pub fn read_uid(&self) -> ConvertingReceiver<u32>
[src]

Returns the current UID as an integer. Encode as Base58 to get the usual string version.

pub fn get_identity(&self) -> ConvertingReceiver<Identity>
[src]

Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.

The position can be 'a', 'b', 'c' or 'd'.

The device identifier numbers can be found here. |device_identifier_constant|

Trait Implementations

impl Clone for VoltageCurrentV2Bricklet
[src]

fn clone_from(&mut self, source: &Self)
1.0.0
[src]

Performs copy-assignment from source. Read more

Auto Trait Implementations

Blanket Implementations

impl<T> From for T
[src]

impl<T, U> Into for T where
    U: From<T>, 
[src]

impl<T> ToOwned for T where
    T: Clone
[src]

type Owned = T

impl<T, U> TryFrom for T where
    T: From<U>, 
[src]

type Error = !

🔬 This is a nightly-only experimental API. (try_from)

The type returned in the event of a conversion error.

impl<T> Borrow for T where
    T: ?Sized
[src]

impl<T> BorrowMut for T where
    T: ?Sized
[src]

impl<T, U> TryInto for T where
    U: TryFrom<T>, 
[src]

type Error = <U as TryFrom<T>>::Error

🔬 This is a nightly-only experimental API. (try_from)

The type returned in the event of a conversion error.

impl<T> Any for T where
    T: 'static + ?Sized
[src]

impl<T> Same for T

type Output = T

Should always be Self