[][src]Struct tinkerforge::industrial_quad_relay_v2_bricklet::IndustrialQuadRelayV2Bricklet

pub struct IndustrialQuadRelayV2Bricklet { /* fields omitted */ }

4 galvanically isolated solid state relays

Methods

impl IndustrialQuadRelayV2Bricklet[src]

pub const DEVICE_IDENTIFIER: u16[src]

pub const DEVICE_DISPLAY_NAME: &'static str[src]

pub fn new<T: GetRequestSender>(
    uid: &str,
    req_sender: T
) -> IndustrialQuadRelayV2Bricklet
[src]

Creates an object with the unique device ID uid. This object can then be used after the IP Connection ip_connection is connected.

pub fn get_response_expected(
    &mut self,
    fun: IndustrialQuadRelayV2BrickletFunction
) -> Result<bool, GetResponseExpectedError>
[src]

Returns the response expected flag for the function specified by the function ID parameter. It is true if the function is expected to send a response, false otherwise.

For getter functions this is enabled by default and cannot be disabled, because those functions will always send a response. For callback configuration functions it is enabled by default too, but can be disabled by set_response_expected. For setter functions it is disabled by default and can be enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is send and errors are silently ignored, because they cannot be detected.

See set_response_expected for the list of function ID constants available for this function.

pub fn set_response_expected(
    &mut self,
    fun: IndustrialQuadRelayV2BrickletFunction,
    response_expected: bool
) -> Result<(), SetResponseExpectedError>
[src]

Changes the response expected flag of the function specified by the function ID parameter. This flag can only be changed for setter (default value: false) and callback configuration functions (default value: true). For getter functions it is always enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is send and errors are silently ignored, because they cannot be detected.

pub fn set_response_expected_all(&mut self, response_expected: bool)[src]

Changes the response expected flag for all setter and callback configuration functions of this device at once.

pub fn get_api_version(&self) -> [u8; 3][src]

Returns the version of the API definition (major, minor, revision) implemented by this API bindings. This is neither the release version of this API bindings nor does it tell you anything about the represented Brick or Bricklet.

pub fn get_monoflop_done_callback_receiver(
    &self
) -> ConvertingCallbackReceiver<MonoflopDoneEvent>
[src]

This receiver is triggered whenever a monoflop timer reaches 0. The parameters contain the channel and the current value of the channel (the value after the monoflop).

pub fn set_value(&self, value: [bool; 4]) -> ConvertingReceiver<()>[src]

Sets the value of all four relays. A value of true closes the relay and a value of false opens the relay.

Use set_selected_value to only change one relay.

All running monoflop timers will be aborted if this function is called.

pub fn get_value(&self) -> ConvertingReceiver<[bool; 4]>[src]

Returns the values as set by set_value.

pub fn set_monoflop(
    &self,
    channel: u8,
    value: bool,
    time: u32
) -> ConvertingReceiver<()>
[src]

Configures a monoflop of the specified channel.

The second parameter is the desired value of the specified channel. A true means relay closed and a false means relay open.

The third parameter indicates the time that the channels should hold the value.

If this function is called with the parameters (0, 1, 1500) channel 0 will close and in 1.5s channel 0 will open again

A monoflop can be used as a fail-safe mechanism. For example: Lets assume you have a RS485 bus and a Industrial Quad Relay Bricklet 2.0 connected to one of the slave stacks. You can now call this function every second, with a time parameter of two seconds and channel 0 closed. Channel 0 will be closed all the time. If now the RS485 connection is lost, then channel 0 will be opened in at most two seconds.

pub fn get_monoflop(&self, channel: u8) -> ConvertingReceiver<Monoflop>[src]

Returns (for the given channel) the current value and the time as set by set_monoflop as well as the remaining time until the value flips.

If the timer is not running currently, the remaining time will be returned as 0.

pub fn set_selected_value(
    &self,
    channel: u8,
    value: bool
) -> ConvertingReceiver<()>
[src]

Sets the output value of the specified channel without affecting the other channels.

A running monoflop timer for the specified channel will be aborted if this function is called.

pub fn set_channel_led_config(
    &self,
    channel: u8,
    config: u8
) -> ConvertingReceiver<()>
[src]

Each channel has a corresponding LED. You can turn the LED off, on or show a heartbeat. You can also set the LED to Channel Status. In this mode the LED is on if the channel is high and off otherwise.

Associated constants:

  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_CHANNEL_LED_CONFIG_OFF
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_CHANNEL_LED_CONFIG_ON
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_CHANNEL_LED_CONFIG_SHOW_HEARTBEAT
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_CHANNEL_LED_CONFIG_SHOW_CHANNEL_STATUS

pub fn get_channel_led_config(&self, channel: u8) -> ConvertingReceiver<u8>[src]

Returns the channel LED configuration as set by set_channel_led_config

Associated constants:

  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_CHANNEL_LED_CONFIG_OFF
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_CHANNEL_LED_CONFIG_ON
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_CHANNEL_LED_CONFIG_SHOW_HEARTBEAT
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_CHANNEL_LED_CONFIG_SHOW_CHANNEL_STATUS

pub fn get_spitfp_error_count(&self) -> ConvertingReceiver<SpitfpErrorCount>[src]

Returns the error count for the communication between Brick and Bricklet.

The errors are divided into

  • ACK checksum errors,
  • message checksum errors,
  • framing errors and
  • overflow errors.

The errors counts are for errors that occur on the Bricklet side. All Bricks have a similar function that returns the errors on the Brick side.

pub fn set_bootloader_mode(&self, mode: u8) -> ConvertingReceiver<u8>[src]

Sets the bootloader mode and returns the status after the requested mode change was instigated.

You can change from bootloader mode to firmware mode and vice versa. A change from bootloader mode to firmware mode will only take place if the entry function, device identifier and CRC are present and correct.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

Associated constants:

  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_BOOTLOADER_MODE_BOOTLOADER
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_BOOTLOADER_STATUS_OK
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_BOOTLOADER_STATUS_INVALID_MODE
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_BOOTLOADER_STATUS_NO_CHANGE
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_BOOTLOADER_STATUS_ENTRY_FUNCTION_NOT_PRESENT
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_BOOTLOADER_STATUS_DEVICE_IDENTIFIER_INCORRECT
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_BOOTLOADER_STATUS_CRC_MISMATCH

pub fn get_bootloader_mode(&self) -> ConvertingReceiver<u8>[src]

Returns the current bootloader mode, see set_bootloader_mode.

Associated constants:

  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_BOOTLOADER_MODE_BOOTLOADER
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT

pub fn set_write_firmware_pointer(&self, pointer: u32) -> ConvertingReceiver<()>[src]

Sets the firmware pointer for write_firmware. The pointer has to be increased by chunks of size 64. The data is written to flash every 4 chunks (which equals to one page of size 256).

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

pub fn write_firmware(&self, data: [u8; 64]) -> ConvertingReceiver<u8>[src]

Writes 64 Bytes of firmware at the position as written by set_write_firmware_pointer before. The firmware is written to flash every 4 chunks.

You can only write firmware in bootloader mode.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

pub fn set_status_led_config(&self, config: u8) -> ConvertingReceiver<()>[src]

Sets the status LED configuration. By default the LED shows communication traffic between Brick and Bricklet, it flickers once for every 10 received data packets.

You can also turn the LED permanently on/off or show a heartbeat.

If the Bricklet is in bootloader mode, the LED is will show heartbeat by default.

Associated constants:

  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_STATUS_LED_CONFIG_OFF
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_STATUS_LED_CONFIG_ON
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_STATUS_LED_CONFIG_SHOW_HEARTBEAT
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_STATUS_LED_CONFIG_SHOW_STATUS

pub fn get_status_led_config(&self) -> ConvertingReceiver<u8>[src]

Returns the configuration as set by set_status_led_config

Associated constants:

  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_STATUS_LED_CONFIG_OFF
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_STATUS_LED_CONFIG_ON
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_STATUS_LED_CONFIG_SHOW_HEARTBEAT
  • INDUSTRIAL_QUAD_RELAY_V2_BRICKLET_STATUS_LED_CONFIG_SHOW_STATUS

pub fn get_chip_temperature(&self) -> ConvertingReceiver<i16>[src]

Returns the temperature in °C as measured inside the microcontroller. The value returned is not the ambient temperature!

The temperature is only proportional to the real temperature and it has bad accuracy. Practically it is only useful as an indicator for temperature changes.

pub fn reset(&self) -> ConvertingReceiver<()>[src]

Calling this function will reset the Bricklet. All configurations will be lost.

After a reset you have to create new device objects, calling functions on the existing ones will result in undefined behavior!

pub fn write_uid(&self, uid: u32) -> ConvertingReceiver<()>[src]

Writes a new UID into flash. If you want to set a new UID you have to decode the Base58 encoded UID string into an integer first.

We recommend that you use Brick Viewer to change the UID.

pub fn read_uid(&self) -> ConvertingReceiver<u32>[src]

Returns the current UID as an integer. Encode as Base58 to get the usual string version.

pub fn get_identity(&self) -> ConvertingReceiver<Identity>[src]

Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.

The position can be 'a', 'b', 'c' or 'd'.

The device identifier numbers can be found here. |device_identifier_constant|

Trait Implementations

impl Clone for IndustrialQuadRelayV2Bricklet[src]

Auto Trait Implementations

Blanket Implementations

impl<T> From<T> for T[src]

impl<T, U> Into<U> for T where
    U: From<T>, 
[src]

impl<T> ToOwned for T where
    T: Clone
[src]

type Owned = T

The resulting type after obtaining ownership.

impl<T, U> TryFrom<U> for T where
    U: Into<T>, 
[src]

type Error = !

The type returned in the event of a conversion error.

impl<T, U> TryInto<U> for T where
    U: TryFrom<T>, 
[src]

type Error = <U as TryFrom<T>>::Error

The type returned in the event of a conversion error.

impl<T> Borrow<T> for T where
    T: ?Sized
[src]

impl<T> BorrowMut<T> for T where
    T: ?Sized
[src]

impl<T> Any for T where
    T: 'static + ?Sized
[src]

impl<T> Same<T> for T

type Output = T

Should always be Self