Expand description
Measures two DC voltages between -35V and +35V with 24bit resolution each.
See also the documentation here.
Structs§
- AllVoltages
Callback Configuration - Calibration
- Channel
LedStatus Config - Identity
- Industrial
Dual Analog InV2 Bricklet - Measures two DC voltages between -35V and +35V with 24bit resolution each
- Spitfp
Error Count - Voltage
Callback Configuration - Voltage
Event
Enums§
Constants§
- INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ BOOTLOADER_ MODE_ BOOTLOADER - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ BOOTLOADER_ MODE_ BOOTLOADER_ WAIT_ FOR_ REBOOT - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ BOOTLOADER_ MODE_ FIRMWARE - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ BOOTLOADER_ MODE_ FIRMWARE_ WAIT_ FOR_ ERASE_ AND_ REBOOT - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ BOOTLOADER_ MODE_ FIRMWARE_ WAIT_ FOR_ REBOOT - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ BOOTLOADER_ STATUS_ CRC_ MISMATCH - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ BOOTLOADER_ STATUS_ DEVICE_ IDENTIFIER_ INCORRECT - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ BOOTLOADER_ STATUS_ ENTRY_ FUNCTION_ NOT_ PRESENT - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ BOOTLOADER_ STATUS_ INVALID_ MODE - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ BOOTLOADER_ STATUS_ NO_ CHANGE - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ BOOTLOADER_ STATUS_ OK - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ CHANNEL_ LED_ CONFIG_ OFF - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ CHANNEL_ LED_ CONFIG_ ON - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ CHANNEL_ LED_ CONFIG_ SHOW_ CHANNEL_ STATUS - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ CHANNEL_ LED_ CONFIG_ SHOW_ HEARTBEAT - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ CHANNEL_ LED_ STATUS_ CONFIG_ INTENSITY - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ CHANNEL_ LED_ STATUS_ CONFIG_ THRESHOLD - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ SAMPLE_ RATE_ 1_ SPS - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ SAMPLE_ RATE_ 2_ SPS - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ SAMPLE_ RATE_ 4_ SPS - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ SAMPLE_ RATE_ 61_ SPS - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ SAMPLE_ RATE_ 122_ SPS - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ SAMPLE_ RATE_ 244_ SPS - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ SAMPLE_ RATE_ 488_ SPS - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ SAMPLE_ RATE_ 976_ SPS - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ STATUS_ LED_ CONFIG_ OFF - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ STATUS_ LED_ CONFIG_ ON - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ STATUS_ LED_ CONFIG_ SHOW_ HEARTBEAT - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ STATUS_ LED_ CONFIG_ SHOW_ STATUS - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ THRESHOLD_ OPTION_ GREATER - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ THRESHOLD_ OPTION_ INSIDE - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ THRESHOLD_ OPTION_ OFF - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ THRESHOLD_ OPTION_ OUTSIDE - INDUSTRIAL_
DUAL_ ANALOG_ IN_ V2_ BRICKLET_ THRESHOLD_ OPTION_ SMALLER