Skip to main content

Module clock

Module clock 

Source
Expand description

Clock synchronisation: a two-dimensional Kalman filter over clock offset and drift.

The filter turns server/time round trips into a mapping from the local monotonic clock to the server clock. One exchange is a TimeSample with four timestamps, all in microseconds:

client_sent_us     T1  local time when the request left
server_received_us T2  server time when the request arrived
server_sent_us     T3  server time when the answer left
client_received_us T4  local time when the answer arrived

Each sample yields one offset measurement (server clock minus local clock) and one error bound for it, both in microseconds:

measurement = ((T2 - T1) + (T3 - T4)) / 2
max_error   = ((T4 - T1) - (T3 - T2)) / 2

The integer arithmetic divides with truncation toward zero, as the protocol specifies. The measurement enters a Kalman filter whose state is the offset and the drift (the rate at which the offset changes, in microseconds per microsecond):

  • the offset performs a random walk with diffusion PROCESS_STD_DEV and the drift one with DRIFT_PROCESS_STD_DEV;
  • the measurement variance grows with max_error, so a sample that crossed a stalled queue moves the estimate far less than a quick one - that is the outlier handling, and it needs no special case;
  • once ADAPTIVE_FORGETTING_AFTER samples are in, a residual larger than ADAPTIVE_CUTOFF times the error bound inflates the covariance by FORGET_FACTOR², so the filter can follow a genuine step instead of treating it as noise;
  • drift is applied to a conversion only while it is statistically significant.

Readiness (ClockFilter::is_ready) is an availability signal, not an accuracy guarantee: it says that an estimate exists, not that it is fresh or good. The estimate’s error grows with the distance from ClockFilter::last_sample_us, so a caller that needs a bounded error keeps feeding samples. The published algorithm has a single 100-sample cutoff, after which adaptive forgetting may start; this module keeps that cutoff for its own purpose and adds a separate, much earlier threshold for availability, because the two answer different questions.

Local timestamps must be positive. The filter starts with last_sample_us == 0 and discards a sample that does not advance it, so a local clock that reads zero or less never gets a sample accepted and never becomes ready.

The module is pure computation: no I/O, no clock reads, no blocking. The caller owns time.

Structs§

ClockFilter
Two-dimensional Kalman filter over clock offset and drift.
TimeSample
The four timestamps of one round trip, in microseconds.

Constants§

READY_AFTER_SAMPLES
Number of accepted samples ClockFilter needs before it reports an estimate.