Expand description

RTC calibration register

Structs

RTC calibration register

Register CALR reader

Register CALR writer

Type Definitions

Field CALM reader - Calibration minus The frequency of the calendar is reduced by masking CALM out of 220 RTCCLK pulses (32 seconds if the input frequency is 32768Â Hz). This decreases the frequency of the calendar with a resolution of 0.9537Â ppm. To increase the frequency of the calendar, this feature should be used in conjunction with CALP. See .

Field CALM writer - Calibration minus The frequency of the calendar is reduced by masking CALM out of 220 RTCCLK pulses (32 seconds if the input frequency is 32768Â Hz). This decreases the frequency of the calendar with a resolution of 0.9537Â ppm. To increase the frequency of the calendar, this feature should be used in conjunction with CALP. See .

Field CALP reader - Increase frequency of RTC by 488.5 ppm This feature is intended to be used in conjunction with CALM, which lowers the frequency of the calendar with a fine resolution. if the input frequency is 32768 Hz, the number of RTCCLK pulses added during a 32-second window is calculated as follows: (512 × CALP) - CALM. Refer to .

Field CALP writer - Increase frequency of RTC by 488.5 ppm This feature is intended to be used in conjunction with CALM, which lowers the frequency of the calendar with a fine resolution. if the input frequency is 32768 Hz, the number of RTCCLK pulses added during a 32-second window is calculated as follows: (512 × CALP) - CALM. Refer to .

Field CALW8 reader - Use an 8-second calibration cycle period When CALW8 is set to 1, the 8-second calibration cycle period is selected. Note: CALM[1:0] are stuck at 00 when CALW8 = 1. Refer to digital calibration.

Field CALW8 writer - Use an 8-second calibration cycle period When CALW8 is set to 1, the 8-second calibration cycle period is selected. Note: CALM[1:0] are stuck at 00 when CALW8 = 1. Refer to digital calibration.

Field CALW16 reader - Use a 16-second calibration cycle period When CALW16 is set to 1, the 16-second calibration cycle period is selected. This bit must not be set to 1 if CALW8 = 1. Note: CALM[0] is stuck at 0 when CALW16 = 1. Refer to calibration.

Field CALW16 writer - Use a 16-second calibration cycle period When CALW16 is set to 1, the 16-second calibration cycle period is selected. This bit must not be set to 1 if CALW8 = 1. Note: CALM[0] is stuck at 0 when CALW16 = 1. Refer to calibration.