pub struct R(_);
Expand description
Register CEC_CFGR
reader
Implementations
sourceimpl R
impl R
sourcepub fn sft(&self) -> SFT_R
pub fn sft(&self) -> SFT_R
Bits 0:2 - Signal Free Time SFT bits are set by software. In the SFT=0x0 configuration the number of nominal data bit periods waited before transmission is ruled by hardware according to the transmission history. In all the other configurations the SFT number is determined by software. * 0x0 ** 2.5 Data-Bit periods if CEC is the last bus initiator with unsuccessful transmission (ARBLST=1, TXERR=1, TXUDR=1 or TXACKE= 1) ** 4 Data-Bit periods if CEC is the new bus initiator ** 6 Data-Bit periods if CEC is the last bus initiator with successful transmission (TXEOM=1) * 0x1: 0.5 nominal data bit periods * 0x2: 1.5 nominal data bit periods * 0x3: 2.5 nominal data bit periods * 0x4: 3.5 nominal data bit periods * 0x5: 4.5 nominal data bit periods * 0x6: 5.5 nominal data bit periods * 0x7: 6.5 nominal data bit periods
sourcepub fn rxtol(&self) -> RXTOL_R
pub fn rxtol(&self) -> RXTOL_R
Bit 3 - Rx-Tolerance The RXTOL bit is set and cleared by software. ** Start-Bit, +/- 200 s rise, +/- 200 s fall. ** Data-Bit: +/- 200 s rise. +/- 350 s fall. ** Start-Bit: +/- 400 s rise, +/- 400 s fall ** Data-Bit: +/-300 s rise, +/- 500 s fall
sourcepub fn brestp(&self) -> BRESTP_R
pub fn brestp(&self) -> BRESTP_R
Bit 4 - Rx-Stop on Bit Rising Error The BRESTP bit is set and cleared by software.
sourcepub fn bregen(&self) -> BREGEN_R
pub fn bregen(&self) -> BREGEN_R
Bit 5 - Generate Error-Bit on Bit Rising Error The BREGEN bit is set and cleared by software. Note: If BRDNOGEN=0, an Error-bit is generated upon BRE detection with BRESTP=1 in broadcast even if BREGEN=0
sourcepub fn lbpegen(&self) -> LBPEGEN_R
pub fn lbpegen(&self) -> LBPEGEN_R
Bit 6 - Generate Error-Bit on Long Bit Period Error The LBPEGEN bit is set and cleared by software. Note: If BRDNOGEN=0, an Error-bit is generated upon LBPE detection in broadcast even if LBPEGEN=0
sourcepub fn brdnogen(&self) -> BRDNOGEN_R
pub fn brdnogen(&self) -> BRDNOGEN_R
Bit 7 - Avoid Error-Bit Generation in Broadcast The BRDNOGEN bit is set and cleared by software.
sourcepub fn sftopt(&self) -> SFTOPT_R
pub fn sftopt(&self) -> SFTOPT_R
Bit 8 - SFT Option Bit The SFTOPT bit is set and cleared by software.
sourcepub fn oar(&self) -> OAR_R
pub fn oar(&self) -> OAR_R
Bits 16:30 - Own addresses configuration The OAR bits are set by software to select which destination logical addresses has to be considered in receive mode. Each bit, when set, enables the CEC logical address identified by the given bit position. At the end of HEADER reception, the received destination address is compared with the enabled addresses. In case of matching address, the incoming message is acknowledged and received. In case of non-matching address, the incoming message is received only in listen mode (LSTN=1), but without acknowledge sent. Broadcast messages are always received. Example: OAR = 0b000 0000 0010 0001 means that CEC acknowledges addresses 0x0 and 0x5. Consequently, each message directed to one of these addresses is received.
Methods from Deref<Target = R<CEC_CFGR_SPEC>>
Trait Implementations
sourceimpl From<R<CEC_CFGR_SPEC>> for R
impl From<R<CEC_CFGR_SPEC>> for R
sourcefn from(reader: R<CEC_CFGR_SPEC>) -> Self
fn from(reader: R<CEC_CFGR_SPEC>) -> Self
Converts to this type from the input type.
Auto Trait Implementations
Blanket Implementations
sourceimpl<T> BorrowMut<T> for T where
T: ?Sized,
impl<T> BorrowMut<T> for T where
T: ?Sized,
const: unstable · sourcefn borrow_mut(&mut self) -> &mut T
fn borrow_mut(&mut self) -> &mut T
Mutably borrows from an owned value. Read more