Struct stm32g0::stm32g0b0::tim3::ccmr1_output::OC1PE_W [−][src]
pub struct OC1PE_W<'a> { /* fields omitted */ }
Expand description
Field OC1PE
writer - Output compare 1 preload enable Note: The PWM mode can be used without validating the preload register only in one-pulse mode (OPM bit set in TIMx_CR1 register). Else the behavior is not guaranteed.
Implementations
Preload register on TIMx_CCR1 disabled. TIMx_CCR1 can be written at anytime, the new value is taken in account immediately.
Preload register on TIMx_CCR1 enabled. Read/Write operations access the preload register. TIMx_CCR1 preload value is loaded in the active register at each update event.