Struct stm32g0::stm32g070::tim15::bdtr::OSSR_W [−][src]
pub struct OSSR_W<'a> { /* fields omitted */ }
Expand description
Field OSSR
writer - Off-state selection for Run mode This bit is used when MOE=1 on channels that have a complementary output which are configured as outputs. OSSR is not implemented if no complementary output is implemented in the timer. See OC/OCN enable description for more details (enable register (TIM15_CCER) on page 818). Note: This bit can not be modified as soon as the LOCK level 2 has been programmed (LOCK bits in TIMx_BDTR register).
Implementations
When inactive, OC/OCN outputs are disabled (the timer releases the output control which is taken over by the AFIO logic, which forces a Hi-Z state)
When inactive, OC/OCN outputs are enabled with their inactive level as soon as CCxE=1 or CCxNE=1 (the output is still controlled by the timer).