Expand description
FDCAN CC control register
Structs§
- CCCRrs
- FDCAN CC control register
Type Aliases§
- ASM_R
- Field
ASM
reader - ASM restricted operation mode The restricted operation mode is intended for applications that adapt themselves to different CAN bit rates. The application tests different bit rates and leaves the Restricted Operation Mode after it has received a valid frame. In the optional Restricted Operation Mode the node is able to transmit and receive data and remote frames and it gives acknowledge to valid frames, but it does not send active error frames or overload frames. In case of an error condition or overload condition, it does not send dominant bits, instead it waits for the occurrence of bus idle condition to resynchronize itself to the CAN communication. The error counters are not incremented. Bit ASM can only be set by software when both CCE and INIT are set to 1. The bit can be reset by the software at any time. - ASM_W
- Field
ASM
writer - ASM restricted operation mode The restricted operation mode is intended for applications that adapt themselves to different CAN bit rates. The application tests different bit rates and leaves the Restricted Operation Mode after it has received a valid frame. In the optional Restricted Operation Mode the node is able to transmit and receive data and remote frames and it gives acknowledge to valid frames, but it does not send active error frames or overload frames. In case of an error condition or overload condition, it does not send dominant bits, instead it waits for the occurrence of bus idle condition to resynchronize itself to the CAN communication. The error counters are not incremented. Bit ASM can only be set by software when both CCE and INIT are set to 1. The bit can be reset by the software at any time. - BRSE_R
- Field
BRSE
reader - FDCAN bit rate switching - BRSE_W
- Field
BRSE
writer - FDCAN bit rate switching - CCE_R
- Field
CCE
reader - Configuration change enable - CCE_W
- Field
CCE
writer - Configuration change enable - CSA_R
- Field
CSA
reader - Clock stop acknowledge - CSR_R
- Field
CSR
reader - Clock stop request - CSR_W
- Field
CSR
writer - Clock stop request - DAR_R
- Field
DAR
reader - Disable automatic retransmission - DAR_W
- Field
DAR
writer - Disable automatic retransmission - EFBI_R
- Field
EFBI
reader - Edge filtering during bus integration - EFBI_W
- Field
EFBI
writer - Edge filtering during bus integration - FDOE_R
- Field
FDOE
reader - FD operation enable - FDOE_W
- Field
FDOE
writer - FD operation enable - INIT_R
- Field
INIT
reader - Initialization - INIT_W
- Field
INIT
writer - Initialization - MON_R
- Field
MON
reader - Bus monitoring mode Bit MON can only be set by software when both CCE and INIT are set to 1. The bit can be reset by the Host at any time. - MON_W
- Field
MON
writer - Bus monitoring mode Bit MON can only be set by software when both CCE and INIT are set to 1. The bit can be reset by the Host at any time. - NISO_R
- Field
NISO
reader - Non ISO operation If this bit is set, the FDCAN uses the CAN FD frame format as specified by the Bosch CAN FD Specification V1.0. - NISO_W
- Field
NISO
writer - Non ISO operation If this bit is set, the FDCAN uses the CAN FD frame format as specified by the Bosch CAN FD Specification V1.0. - PXHD_R
- Field
PXHD
reader - Protocol exception handling disable - PXHD_W
- Field
PXHD
writer - Protocol exception handling disable - R
- Register
CCCR
reader - TEST_R
- Field
TEST
reader - Test mode enable - TEST_W
- Field
TEST
writer - Test mode enable - TXP_R
- Field
TXP
reader - If this bit is set, the FDCAN pauses for two CAN bit times before starting the next transmission after successfully transmitting a frame. - TXP_W
- Field
TXP
writer - If this bit is set, the FDCAN pauses for two CAN bit times before starting the next transmission after successfully transmitting a frame. - W
- Register
CCCR
writer