Expand description
Power control register 3
Structs§
- CR3rs
- Power control register 3
Type Aliases§
- APC_R
- Field
APC
reader - Apply pull-up and pull-down configuration When this bit is set, the I/O pull-up and pull-down configurations defined in the PWR_PUCRx and PWR_PDCRx registers are applied. When this bit is cleared, the PWR_PUCRx and PWR_PDCRx registers are not applied to the I/Os. - APC_W
- Field
APC
writer - Apply pull-up and pull-down configuration When this bit is set, the I/O pull-up and pull-down configurations defined in the PWR_PUCRx and PWR_PDCRx registers are applied. When this bit is cleared, the PWR_PUCRx and PWR_PDCRx registers are not applied to the I/Os. - EIWUL_R
- Field
EIWUL
reader - Enable internal wakeup line - EIWUL_W
- Field
EIWUL
writer - Enable internal wakeup line - EWUP1_R
- Field
EWUP1
reader - Enable Wakeup pin WKUP1 When this bit is set, the external wakeup pin WKUP1 is enabled and triggers a wakeup from Standby or Shutdown event when a rising or a falling edge occurs. The active edge is configured via the WP1 bit in the PWR_CR4 register. - EWUP1_W
- Field
EWUP1
writer - Enable Wakeup pin WKUP1 When this bit is set, the external wakeup pin WKUP1 is enabled and triggers a wakeup from Standby or Shutdown event when a rising or a falling edge occurs. The active edge is configured via the WP1 bit in the PWR_CR4 register. - EWUP2_R
- Field
EWUP2
reader - Enable Wakeup pin WKUP2 When this bit is set, the external wakeup pin WKUP2 is enabled and triggers a wakeup from Standby or Shutdown event when a rising or a falling edge occurs. The active edge is configured via the WP2 bit in the PWR_CR4 register. - EWUP2_W
- Field
EWUP2
writer - Enable Wakeup pin WKUP2 When this bit is set, the external wakeup pin WKUP2 is enabled and triggers a wakeup from Standby or Shutdown event when a rising or a falling edge occurs. The active edge is configured via the WP2 bit in the PWR_CR4 register. - EWUP3_R
- Field
EWUP3
reader - Enable Wakeup pin WKUP3 When this bit is set, the external wakeup pin WKUP3 is enabled and triggers a wakeup from Standby or Shutdown event when a rising or a falling edge occurs. The active edge is configured via the WP3 bit in the PWR_CR4 register. - EWUP3_W
- Field
EWUP3
writer - Enable Wakeup pin WKUP3 When this bit is set, the external wakeup pin WKUP3 is enabled and triggers a wakeup from Standby or Shutdown event when a rising or a falling edge occurs. The active edge is configured via the WP3 bit in the PWR_CR4 register. - EWUP4_R
- Field
EWUP4
reader - Enable Wakeup pin WKUP4 When this bit is set, the external wakeup pin WKUP4 is enabled and triggers a wakeup from Standby or Shutdown event when a rising or a falling edge occurs. The active edge is configured via the WP4 bit in the PWR_CR4 register. - EWUP4_W
- Field
EWUP4
writer - Enable Wakeup pin WKUP4 When this bit is set, the external wakeup pin WKUP4 is enabled and triggers a wakeup from Standby or Shutdown event when a rising or a falling edge occurs. The active edge is configured via the WP4 bit in the PWR_CR4 register. - EWUP5_R
- Field
EWUP5
reader - Enable Wakeup pin WKUP5 When this bit is set, the external wakeup pin WKUP5 is enabled and triggers a wakeup from Standby or Shutdown event when a rising or a falling edge occurs.The active edge is configured via the WP5 bit in the PWR_CR4 register. - EWUP5_W
- Field
EWUP5
writer - Enable Wakeup pin WKUP5 When this bit is set, the external wakeup pin WKUP5 is enabled and triggers a wakeup from Standby or Shutdown event when a rising or a falling edge occurs.The active edge is configured via the WP5 bit in the PWR_CR4 register. - R
- Register
CR3
reader - RRS_R
- Field
RRS
reader - SRAM2 retention in Standby mode - RRS_W
- Field
RRS
writer - SRAM2 retention in Standby mode - UCPD1_
DBDIS_ R - Field
UCPD1_DBDIS
reader - USB Type-C and Power Delivery Dead Battery disable. After exiting reset, the USB Type-C dead battery behavior is enabled, which may have a pull-down effect on CC1 and CC2 pins. It is recommended to disable it in all cases, either to stop this pull-down or to hand over control to the UCPD1 (which should therefore be initialized before doing the disable). - UCPD1_
DBDIS_ W - Field
UCPD1_DBDIS
writer - USB Type-C and Power Delivery Dead Battery disable. After exiting reset, the USB Type-C dead battery behavior is enabled, which may have a pull-down effect on CC1 and CC2 pins. It is recommended to disable it in all cases, either to stop this pull-down or to hand over control to the UCPD1 (which should therefore be initialized before doing the disable). - UCPD1_
STDBY_ R - Field
UCPD1_STDBY
reader - UCPD1_STDBY USB Type-C and Power Delivery standby mode. - UCPD1_
STDBY_ W - Field
UCPD1_STDBY
writer - UCPD1_STDBY USB Type-C and Power Delivery standby mode. - W