Clean-room readers for biophysical bench instruments.
- MicroCal isothermal titration calorimetry (
microcal-itc,.itc: VP-ITC, iTC200 and the MicroCal ITC software): the thermogram (differential power and cell temperature against time) as a trace, the injections (volume, duration, spacing, filter period, start) as a table, and the method (cell and syringe concentrations, cell volume, temperature, stirring, reference power) in the experiment model. Notes:docs/formats/microcal-itc.md. - Cytiva Biacore surface plasmon resonance (
cytiva-biacore-blr,.blrresult files of the Biacore T200 Control Software): every stored sensorgram (raw flow cells and reference-subtracted curves, per cycle) as a trace, the control software’s report points, the cycles and the event log as tables, chip and run in the vendor tree and experiment model. Notes:docs/formats/cytiva-biacore.md. - Agilent Seahorse XF (
agilent-seahorse-asyr,.asyrassay results of Wave): the O2 and pH sensors’ corrected emission per well at every plate reading as traces, the plate map, measurements, injections and executed protocol as tables, and the oxygen consumption, extracellular acidification and proton efflux rates computed with the published compartment model where the plate and settings are those validated against Wave’s own rates. Notes:docs/formats/agilent-seahorse.md. - GenePix Results (
genepix-gpr,.gprof GenePix Pro): the microarray feature table (every column GenePix wrote) and the scan settings. Notes:docs/formats/genepix-gpr.md. - Sartorius Octet (
sartorius-octet-frd,.frdbiolayer-interferometry results): one biosensor’s sensorgram through every assay step as a trace, the steps as a table, the instrument and run in the experiment model. Notes:docs/formats/sartorius-octet.md. - Malvern Zetasizer (
malvern-zetasizer-dts,.dtsmeasurement files): one row per record with the sample, date and temperature and the stored zeta results (zeta potential, mobility, conductivity, peaks); size results are withheld until validated. Notes:docs/formats/malvern-zetasizer.md.
§Example
use openreadout_core::FormatReader;
use openreadout_biophys::ItcReader;
assert_eq!(ItcReader.descriptor().id, openreadout_biophys::ITC_FORMAT_ID);Reading a file:
use std::path::Path;
use openreadout_core::FormatReader;
use openreadout_biophys::ItcReader;
let mut dataset = ItcReader.open(Path::new("run.itc"))?;
let thermogram = dataset.read_trace(0, 0, 0, u64::MAX)?; // µcal/s, °C
let injections = dataset.read_table(0, 0, u64::MAX)?;
println!("{} samples, {} injections", thermogram.channels[0].len(), injections.columns[0].len());§API stability
The supported API is what this page documents: the readers, their format ids and the datasets they return.
Structs§
- Biacore
Dataset - An opened
.blrfile. - Biacore
Evaluation Reader - The Cytiva Biacore T200 evaluation-file reader (
.bme): the sensorgrams of the result files it holds, and the evaluation software’s fits. - Biacore
Reader - The Cytiva Biacore result-file reader (
.blr). - GprDataset
- An opened
.gprfile. - GprReader
- The GenePix Results reader (
.gpr). - ItcDataset
- An opened
.itcfile. - ItcReader
- The MicroCal ITC reader (
.itc). - Octet
Reader - The Sartorius Octet
.frdreader (one biosensor’s sensorgram and assay steps). - Seahorse
Dataset - An opened
.asyrfile. - Seahorse
Reader - The Agilent Seahorse XF assay-result reader (
.asyr). - Zetasizer
Reader - The Malvern Zetasizer
.dtsreader.
Constants§
- BIACORE_
BME_ FORMAT_ ID - Format id of Cytiva Biacore T200 evaluation files (
.bme). - BIACORE_
FORMAT_ ID - Format id of Cytiva Biacore
.blrresult files. - GPR_
FORMAT_ ID - Format id of GenePix Results
.gprfiles. - ITC_
FORMAT_ ID - Format id of MicroCal
.itcfiles. - OCTET_
FORMAT_ ID - Format id of Sartorius (ForteBio) Octet
.frdbiolayer-interferometry result files. - SEAHORSE_
FORMAT_ ID - Format id of Agilent Seahorse XF
.asyrassay result files. - ZETASIZER_
FORMAT_ ID - Format id of Malvern Zetasizer
.dtsmeasurement files.